UTC Fire and Security Americas 983-UDWS Wireless Door-Window Sensor User Manual Micro Door Window Sensor Installation Instructions
UTC Fire & Security Americas Corporation, Inc. Wireless Door-Window Sensor Micro Door Window Sensor Installation Instructions
User Manual
Micro Door/Window Sensor Installation Sheet sensor number assignments. Description The Micro Door/Window Sensor is a supervised, wireless sensor that detects the opening and closing of doors, windows, or drawers. The sensor and magnet are mounted using double-sided adhesive tape or screws (included). When activated, the sensor transmits an open (trip) or close (restore) signal to the panel. These are the signals the unit provides: supervisory, tamper and low battery (as needed). The sensor is powered by a replaceable 3VDC, lithium coin-cell battery. Installation guidelines • • • • Mounting the sensor on metal can reduce its transmitting range. Therefore, test the sensor from the desired location using the dealer sensor test, before permanently mounting it. Mount the sensor within 100 ft. of the panel. Mount the sensor on the frame, and the magnet on the door, window, or drawer. If mounting on double doors, mount the sensor on the least used door and the magnet on the other door. Mount sensors at least 5 inches above the floor to avoid damaging them. Programming The following steps describe the general guidelines for programming (learning) the sensor into panel memory. Refer to the specific panel’s documentation for complete programming details. 1. Set the panel to the program mode. 2. Proceed to the LEARN SENSORS menu. 3. Select the appropriate sensor group and P/N 466-4430 • REV A.09 • 24Jul13 4. When prompted by the panel to trip the sensor for learning, remove the battery pull tab or remove the sensor cover. The system should acknowledge learning the sensor by touchpad display and/or audio (depending on the panel). 5. Exit program mode. Testing the sensor 1. Set the panel to the sensor test mode. 2. Take the sensor and magnet to the desired mounting location, making sure to line up their alignment marks with each other. 3. Trip the sensor by pulling the magnet away from the sensor. 4. Listen for the system siren beeps to determine the appropriate response and refer to the specific panel documentation. Mounting the sensor Mount the sensor after successful programming and testing are completed, using the supplied mounting screws for all UL installations. For nonUL installations, using the supplied double-sided tape is optional. Note: The gap between the sensor and magnet should be a maximum of 3/8”. Mounting screws (UL Installations) 1. Remove the sensor base from the sensor. 2. Place the sensor base in desired location and mount the base with the supplied screws. Attach the sensor to the base. 1/2 3. Mount the magnet into the desired location using the supplied screw and lock washer, making sure the alignment mark lines up with the sensor’s. Varta CR2032 Panasonic CR2032 Operating temperature range 32 to 120°F (0 to 49°C) Double-sided tape (optional for non-UL installations) Storage temperature range -30 to 140°F (-34 to 60°C) Relative humidity 0-85% non-condensing 1. Dimensions (L x W x D) 1.9 x 1.0 x 0.50 in. (4.7 x 2.5 x 1.3 cm) Before applying double-sided tape, ensure that the desired location is a smooth, clean and dry surface. Note: When applying the double-sided tape, evenly apply pressure to ensure a good surface contact. 2. 3. Apply double-sided tape to the bottom of the sensor and the magnet. Mount the sensor and magnet at the desired locations, ensuring the alignment marks line up with each other. Regulatory information Manufacturer UTC Fire & Security Americas Corporation, Inc. 1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA FCC compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: B4Z-983-UDWS IC: 1175C-983UDWS Retest the sensor using the procedure in the section “Testing the Sensor”. For additional tamper security 1. 2. This Class B digital apparatus complies with Canadian ICES-003. Punch out the seal covering the screw hole on the sensor cover. With the sensor base secured to the sensor, insert the smallest screw supplied, securing the sensor base to the sensor. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. UL UL 1023 – Household Burglar-Alarm System Units. Replacing the battery 1. Remove the sensor from the base then remove the inner cover, exposing the battery. 2. Remove the bad battery and install the new battery. NOTE: Observe polarity of the battery. 3. Re-install the PC board, inner cover and the sensor. Specifications ANSI/UL 634 Connectors and Switches for Use with Burglar-Alarm Systems ULC C634-M1986 - Connectors and Switches for Use with Burglar-Alarm Systems Contact information For contact information, see www.utcfireandsecurity.com, www.interlogix.com or call +1 855 286 8889. Trademark/Copyright Model no. TX-1012-01-1 (white) TX-1012-01-3 (brown) © 2013 UTC Fire & Security Americas RF frequency 319.5 MHz Corporation, Inc. Interlogix is part of UTC Compatibility Interlogix Learn Mode Panels and Receivers Climate Controls & Security, a unit of United Battery type 3-VDC, lithium coin-cell battery UL Approved Battery Duracell DL2032 2/2 Technologies Corporation. All rights reserved. Micro Door/Window Sensor Installation Instructions
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 2 Language : en-US Tagged PDF : Yes Title : Micro Door/Window Sensor Installation Instructions Author : Brian Borchardt Subject : Micro Door/Window Sensor Creator : Microsoft® Word 2010 Create Date : 2013:07:24 08:56:04-05:00 Modify Date : 2013:07:24 08:56:04-05:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools