UTC Fire and Security Americas 984-PANIC TX-4200-01 User Manual Personal Panic Device Installation Sheet

UTC Fire & Security Americas Corporation, Inc. TX-4200-01 Personal Panic Device Installation Sheet

User Manual

Download: UTC Fire and Security Americas 984-PANIC TX-4200-01 User Manual Personal Panic Device Installation Sheet
Mirror Download [FCC.gov]UTC Fire and Security Americas 984-PANIC TX-4200-01 User Manual Personal Panic Device Installation Sheet
Document ID2079993
Application IDVrAMBpMrKWJFq5jpNbZkXQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize23.29kB (291144 bits)
Date Submitted2013-09-23 00:00:00
Date Available2013-09-23 00:00:00
Creation Date2013-08-21 09:07:29
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2013-08-21 09:07:29
Document TitlePersonal Panic Device Installation Sheet
Document CreatorMicrosoft® Office Word 2007
Document Author: Brian Borchardt

Personal Panic Device Installation Sheet
Description
•
The transmitter on the Personal
Panic Device has a maximum
range of 375 feet. Test the device
at the outer limits of the
installation. The outer limits may
vary due to different environments
that may affect the range.
•
Verify the user can activate the
help button by pressing it with their
thumb or finger.
•
When worn as a pendant, it is
important that the user does not
activate the help button by
pressing it against their chest. This
may reduce the signal’s effective
range.
The water resistant Personal Panic
Device is a wireless device that can be
used to activate police or auxiliary
alarms throughout the premises. When
the help button is pressed, both red
LEDs flash and information is
transmitted. The transmitted signal
includes alarm and battery status
information. When the help button is
released, an alarm-restore-all message
is sent. Note: When pressing the help
button, wait until the red LEDs stop
flashing, then release the button.
Watch style wristband
Adjust the length of the wristband by
measuring and cutting the band in the
following manner:
1.
Position the wristband tightly
The Personal Panic Device is shipped
around the wrist and in the
with a watch type wristband installed. A
intended position as shown in Step
pendant adaptor kit and lanyard are
2.
also included for an optional necklace
2.
Using a washable marker, place a
arrangement. The pendant kit includes
mark on the edge of each strap,
two plugs (shown below).
near the center of the wrist.
Installation
Assembly guidelines
•
Program the Personal Panic
Device into the appropriate panel
groups.
3.
P/N 466-4431 • REV A.07 • Model No. • 21Aug13
Align the band so the ends of the
band are even. Cut the band in the
center of the two marks as shown
below.
4.
Attach the band to the clasp. Feed
4.
Separate the components from the
pendant adaptor kit and discard
the circular center section.
5.
Insert the pendant loop adapter
into the small loop end of the
lanyard.
6.
Insert the plugs into the base and
reattach the cover and base.
Note: Compress the panic button
and base assembly together
before tightening the screws.
the band through the retainer
opening and close the lever to lock
the band in place. Repeat for the
other side.
Pendant
The Personal Panic Device can be
worn as a pendant by removing the
wristband and installing the pendent
adaptor components and lanyard in the
following manner:
1.
Remove the two screws on the
back of the Personal Panic
Device.
2.
Carefully separate the cover and
base.
3.
Remove the wristband.
Programming
Review the following information for
adding a Personal Panic Device to the
2/5
Personal Panic Device Installation She
panel. Refer to the specific panel
Replacing the battery
Installation Instructions for further
detail.
1.
Set the panel to Program Mode.
2.
When prompted, enter the
appropriate group number and
select the desired sensor number.
Caution: To avoid an alarm condition
you must set the panel to Sensor Test
Mode prior to changing the battery.
3.
4.
Press the help button on the
Personal Panic Device to trip the
selected sensor.
Exit from Program Mode.
Maintenance and testing
Caution: You must be free of static
electricity while handling the transmitter
circuit board. Touch a grounded metal
surface before touching the circuit
board.
1.
Remove the two screws on the
back of the Personal Panic Device
and observe how the pendant or
wristband components are
attached.
2.
Carefully separate the cover and
base.
3.
Remove the electronic sub
assembly from the base.
Testing
Review the following for testing the
help button. Refer to the specific panel
Installation Instructions for further
detail.
1.
Set the panel to Sensor Test
Mode.
4.
Remove the battery from the
electronic sub assembly.
2.
Press and hold the help button for
a second to monitor the beeps for
the packet count.
5.
Install the new battery. Observe
polarity.
3.
Listen for panel sirens. You should
hear 6 to 8 beeps.
4.
Test the help button from several
locations to ensure a consistent
response.
5.
Test the help button weekly to
ensure proper operation.
Note: Install Panasonic CR1632.
Cleaning
1.
Gently rub a lanoline-based
cleaner, such as Go-Jo, onto all
surfaces of the Personal Panic
Device to remove any debris.
2.
Rinse off using warm water.
3.
Wipe clean using a dry, lint-free
cloth.
6.
Personal Panic Device Installation Sheet
Place the electronic sub assembly
into the base. Note: A generic
diagram is shown above. For
diagrams showing the wristband
and pendant configurations, see
the assembly diagrams in the
“Installation/Pendant” section.
7.
Inspect the water seal area and
the plugs to ensure they are free
from debris.
8.
Reattach the cover, lanyard
assembly or wristband and the
base. Note: Press the pushbutton
and cover together before
tightening the screws.
9.
Test the help button for proper
operation.
Specifications
Model no.
TX-4200-01-1 (white)
TX-4200-01-2 (black)
RF frequency
319.5 MHz
Compatibility
Interlogix Learn Mode Panels
and Receivers
Battery type
3.0 V lithium (CR1632)
Recommended
battery:
Panasonic CR1632
Typical standby
current (μA):
≤1
Estimated battery
life (at 20° C):
4 years
Supervisory
interval:
Less than 64 minutes
Typical RF output
power:
.25 mW
Operating
32° to 120°F (0° to 49°C)
temperature range
Storage
-30 to 140°F (-34 to 60°C)
temperature range
Relative humidity
5-90% non-condensing
Dimensions
(L x W x D)
1.60 x 1.40 x 0.410 in. (4.1 x
3.6 x 1.0 cm)
4/5
Personal Panic Device Installation She
Regulatory Information
This device complies with FCC Rules
Part 15. Operation is subject to the
following two conditions:
1.
2.
This device may not cause harmful
interference.
This device must accept any
interference that may be received,
including interference that may
cause undesired operation.
Changes or modifications not expressly
approved by Interlogix can void the
user’s authority to operate the
equipment.
FCC ID:
B4Z-984-PANIC
IC:
1175C-984PANIC
US Patents
4,855,713; 4,864,636, and
others pending.
Contact information
For general information, see
www.utcfireandsecurity.com or
www.interlogix.com. For customer
support, see
www.interlogix.com/customer-support
or call +1 855 286 8889.
Trademark/Copyright
© 2013 UTC Fire & Security Americas
Corporation, Inc. Interlogix is part of
UTC Climate Controls & Security, a unit
of United Technologies Corporation. All
rights reserved.
Personal Panic Device Installation Sheet
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved
by Interlogix can void the user’s authority to
operate the equipment.
FCC ID: B4Z-984-PANIC
IC: 1175C-984PANIC
This Class B digital apparatus complies with
Canadian ICES-003.
Cet appareil numérique de la classe B est
conforme à la norme NMB-003 du Canada.
Le fonctionnement est soumis aux deux
conditions suivantes : (1) cet appareil peut ne
pas provoquer d’interférences et (2) cet appareil
doit accepter toutes interférences, y compris les
interférences pouvant provoquer un
fonctionnement non désiré de l’appareil.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 5
Language                        : en-US
Tagged PDF                      : Yes
Title                           : Personal Panic Device Installation Sheet
Author                          : Brian Borchardt
Subject                         : Personal Panic Device
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2013:08:21 09:07:29
Modify Date                     : 2013:08:21 09:07:29
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: B4Z-984-PANIC

Navigation menu