UTC Fire and Security Americas RF4004-01-2 GE 4 Button TX 5003-01 User Manual 466 2283A 4 button kf inin

UTC Fire & Security Americas Corporation, Inc. GE 4 Button TX 5003-01 466 2283A 4 button kf inin

Users Manual

Download: UTC Fire and Security Americas RF4004-01-2 GE 4 Button TX 5003-01 User Manual 466 2283A 4 button kf inin
Mirror Download [FCC.gov]UTC Fire and Security Americas RF4004-01-2 GE 4 Button TX 5003-01 User Manual 466 2283A 4 button kf inin
Document ID802612
Application IDpDxPxYF492LzSyenzZCjig==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize5.86kB (73285 bits)
Date Submitted2007-06-12 00:00:00
Date Available2007-06-12 00:00:00
Creation Date2006-06-27 13:43:39
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2007-06-01 11:08:35
Document Title466-2283A-4-button-kf-inin.fm
Document CreatorFrameMaker 7.0
Document Author: 208037844

4-Button Slimline Keyfob
Installation Instructions
466-2283A • June 2007
Copyright © 2007, GE Security Inc.
Introduction
This is the GE 4-Button Slimline Keyfob Installation Instructions. The keyfob enables you to turn the system on and off after
exiting or before entering the home or to turn on the siren and
call the central monitoring station if there is an emergency. If
lamp modules have been installed, you can use the keyfob to turn
all system-controlled lights on or off.
The keyfob is a lithium coin battery-powered, wireless keyfob
designed to fit on a keychain, in a pocket, or in a purse. It
provides a convenient option for the following system
operations:
• Arm the system (doors, windows, and motion sensors).
• Arm the system with no entry delay (if programmed).
• Disarm the system.
• Trigger panic alarms.
• Turn system-controlled lights on or off.
• Open the garage door or turn outside lights on (if
programed).
Programming guidelines
Refer to your control panel documentation for instructions on
programming and sensor testing your keyfob. Use the following
guidelines to add keyfobs to the system:
• Program (learn) the keyfobs into the control panel as nonsupervised sensors.
• Each learned keyfob uses one of the available sensor
numbers.
• Use sensor group number 01, 03, 06, or 07.
Keyfob test
Refer to your control panel documentation to initiate panel test
mode, then test the keyfob by pressing the keyfob buttons
(Figure 1):
Unlock button. Disarms the control panel. The doors,
windows, and motion sensors are disarmed.
Lock button. The following key presses will depend on
your control panel configuration.
• If pressed once, the control panel arms doors and
windows (stay mode).
• If pressed twice, the control panel arms motion
sensors, doors, and windows (away mode).
• If pressed three times, the control panel activates the
latchkey feature when this option is off (Simon 3 and
Simon XT only).
Lock and Unlock buttons. If the keyfob is programmed
(learned) as an intrusion, silent alarm, or emergency sensor
type, when you press the Lock and Unlock buttons simultaneously, the keyfob will activate alarm reports to the central
station. These two buttons are also used to test the sensor.
Light button. Toggles system-controlled lights on/off.
Star button. If used with the X-10 universal module, the
control panel will cause the garage door to open or close.
Figure 1. Keyfob buttons
LED
Lock button
Unlock button
Light button
Star button
FCC compliance
This device complies with part 15 of the FCC rules. Operation is subject to the
following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference
that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Specifications
Power source
Dimensions (L x W x H)
Typical battery life
Operating temperature
CR2025 3V, 165 mAh lithium coin battery
2.2 x 1.2 x 0.4 in. (57 x 32 x 11 mm)
5 to 8 years
32 to 120°F (0 to 49°C)
Technical support
Toll-free: 888.GESECURity (888.437.3287 in the US, including Alaska and Hawaii; Puerto Rico; Canada).
Outside the toll-free area: Contact your local dealer.
www.gesecurity.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Mode                       : UseOutlines
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Copyright                       : GE Security Inc.
Marked                          : True
Creator Tool                    : FrameMaker 7.0
Modify Date                     : 2007:06:01 11:08:35Z
Create Date                     : 2006:06:27 13:43:39Z
Format                          : application/pdf
Title                           : 466-2283A-4-button-kf-inin.fm
Creator                         : 208037844
Document ID                     : uuid:5f970794-159f-4f2f-915d-9f4e8029e73b
Instance ID                     : uuid:7331e90f-1bf9-4952-8e34-cc5488e8e514
Page Count                      : 1
Author                          : 208037844
EXIF Metadata provided by EXIF.tools
FCC ID Filing: B4Z-RF4004-01-2

Navigation menu