UTC Fire and Security AA2 Field Disturbance Sensor for Security Systems User Manual

UTC Fire & Security B.V. Field Disturbance Sensor for Security Systems

Contents

User Manual

EXHIBIT B – User ManualFCC ID#  CGGAA2
1Sentrol RCRSentrol RCRRange-Controlled Radar DetectorModels: RCR-A (Form A)RCR-C (Form C)Installation InstructionsDescriptionThe RCR detector combines range-controlled radar (RCR)technology with a passive infrared (PIR) system to increasefalse alarm immunity by allowing it to sense human-sizedobjects within a specified range. Both the RCR and PIR systemsmust be triggered to set off an alarm, unless in Microwaveonly mode.The detector is designed to use a 12VDC power supply pro-vided by a UL Listed alarm control panel.Features The detector provides the following features:·High-security mode - Internal jumper allows you to disablethe PIR, and use the RCR system only to detect intrudersfaster. This mode can be used for covert installations(mounted behind ceiling panels or walls).·Selectable range up to 35 feet - Internal jumper allowsradar range selection to optimize coverage.·LED indicator - A multi-color LED provides detector status.·Tamper switch (RCR-C only) - Activated when the pins onthe circuit board are removed from the terminal sockets onthe base.PartsThe following parts are included with the detector:·RCR detector·1 screw to join the case halves·3 factory-installed jumpersSelecting a Location for the DetectorThe detector can be mounted in a corner or on a flat wall. Usethe following guidelines to determine the best location to installthe detector:·Mount the detector so the expected movement of an intruderis across the detection pattern. See Figure 2.·Mount the detector on a stable surface 7 to 9 feet high.·DO NOT mount the detector within 2 feet of any metallicobjects.·DO NOT place any objects in front of the detector that mayprevent a clear line of sight. (Not applicable in RCR onlymode.)·Avoid locations that expose the detector to possible falsealarm sources such as: Moving or vibrating objects (fans, pulleys, conveyor belts) Electronic fields (electric motors, high voltage equipment) Water spray or corrosive environments Heat sources in the field of view (heaters, radiators) Windows in the field of view Strong air drafts on the detector (fans, air conditioners)·When installing multiple detectors: DO NOT mount detectors facing each other Use the 9-foot range when mounting detectors back to back Mount them at least 20 feet apart Use shorter range settings to avoid overlapping radar  coverageFigure 2 - RCR and PIR Coverage PatternsSPRTMPRTMPRNO COMFigure 1 - Detector (exploded)0'6.9'9' 18' 27' 35'Side View900'9'18'27'35'35'27'18'9'Top ViewRCR Viewing AreaPIR Viewing Area°
2Sentrol RCRFigure 3 - Detector BaseInstalling the DetectorAll wiring must conform to National Electric Code (NEC) and/orlocal codes having jurisdiction.Important: DO NOT use this device for safetyinterlock applications.Use the following steps to install the detector:1. Run the security system wiring to the detector location.2. To remove the front cover/electronic module, press down onthe lever at the bottom of the unit and pull the cover off.Remove the nameplate and loosen the screw if necessary. Toremove the nameplate, insert a small screwdriver into one ofthe nameplate side slots and gently push in on the nameplate.See Figure 1.CAUTION! Use anti-static precautions when handlingthe circuit board.3. If necessary, set the jumpers on the circuit board. See Settingthe Jumpers.4. Remove the appropriate wiring and mounting knockout holesfrom the back cover. The detector can be mounted on a flatwall or in a corner. See Figure 3.5. Pull the wires through the knockout holes and use the twoscrews provided to attach the base to the wall. Use screwanchors if necessary.6. Strip 1/4 inch of insulation from each wire.7. Run each wire through the strain relief and under the appro-priate screw terminals on the base and tighten the screws.See Figure 3.8. Line up the tabs on the bottom of the cover/electronic modulewith the corresponding tabs on bottom of the base and snapthe cover/electronic module firmly down onto the base.9. Tighten the screw and replace the nameplate. See Figure 1.10. Apply power. The green LED should light for approximately25 seconds and then go out.11. Walk test the coverage pattern as follows: Walk throughout the intended coverage area. Verify the detector alarms. See Understanding the LED.Note: Most units walk test more accurately if the persontesting waits 10 seconds between tripping the unit andwalking again. This allows the detector to stabilize betweentrips.TerminalsocketsFigure 4 - Main Circuit BoardJ4J3J2MicrowaveonlyRangeLED DisableSpare RCR-C only
3Sentrol RCRImportant: You need to set J2 as close to the intendedcoverage range as possible. Overshooting the coveragearea may cause false alarms.J3 LED - ON = LED enabled (factory default)OFF = LED disabledJ4 PIR - ON = RCR Microwave onlyOFF = PIR enabled (factory default)Understanding the LEDThe multi-color LED located on the bottom of the detectorindicates the status of the unit as described in the followingtable.Maintaining the DetectorWhen installed and used properly, the detector provides years ofservice with minimal maintenance. You should walk test thedetector annually to ensure proper operation.When the cover is removed, power is interrupted to the sensor.Once the cover has been replaced, the green LED will illuminatefor 15 seconds while the sensor warms up. After the green LEDgoes off, wait one minute and walk test the sensor.SB01 Swivel Mount BracketFor ceiling-mount applications that require 90 degree coverage,an optional ceiling-mount swivel bracket (SB01) is availablefrom Interlogix. See Figure 5.Figure 5 - SBO1 Swivel-Mount BracketDEL sutatSdeRdnamralanisirotcetedehT.noitcetedRCRdnaRIP .dehctiwssahyalerehtneerG.)mralaon(ylnonoitcetedRIPwolleY.)mralaon(ylnonoitcetedRCRSetting the JumpersThe detector provides jumpers to select the detection range andPIR and LED operation. See Figure 4.J2 Range - Use the jumper to cover the center pin and the pinindicating the desired range. No jumper = 27 feet and under.9 feet and under 18 feet and under27 feet and under 35 feet and under (factory default)9'18'35'27'9'18'35'27'9'18'35'27'9'18'35'27'In RCR microwave only mode:DEL sutatSdeR.noitcetedevaworcimRCR
4Sentrol RCRProduct OrderingSpecificationsInput voltage.......................8.5 to 18 VDC (UL: 10 to 16VDC)Typical current..................................................................20mAMaximum current..............................................................27mAElectrical configuration.....................................RCR-A: Form A   RCR-C: Form CRelay rating..............................RCR-A: 200VDC, 500mA max.       RCR-C: 200VDC, 250mA max.Tamper (RCR-C only)........................................100ma, 50VDCDetection range..............................................35' (10.7 m) x 90°Target velocity..............................................0.5 ft/sec to 5 ft/secAlarm duration....................................................................5 secMounting height.......................................7' to 9' (2.1 to 2.75 m)Operating temperature........................32° to 122°F (0° to 50°C)Relative humidity...............................5 to 95%  non-condensingDimensions:Width..................................................................2.8" (7.1 cm)Depth..................................................................2.3" (5.7 cm)Height..................................................................5.1" (13 cm)Weight......................................................................6 oz (170 g)Color......................................................................................whiteField wiring size.......................................................16-24 AWGFCC ComplianceThis device complies with Part 15 of the FCC rules. Opera-tion is subject to the following two conditions:(1) this device may not cause harmful interference(2) this device must accept any interference received,including interference that may cause undesired operation.FCC ID:rebmuNledoM noitpircseDA-RCRyalerAmrofhtiwrotcetedradardellortnoc-egnaRC-RCR stcatnocrepmatdnayalerCmrofhtiwrotcetedradardellortnoc-egnaRseirosseccA10BStekcarbtnuom-leviwS1035261 Rev A    04/01