UTStarcom Korea Technologies UTS-800FSU Wireless Local Loop Fixed Subscriber Unit User Manual WARNING FCC RF EXPOSURE COMPLIANCE
UTStarcom Korea Technologies Ltd. Wireless Local Loop Fixed Subscriber Unit WARNING FCC RF EXPOSURE COMPLIANCE
Contents
- 1. FSU Manual Cover
- 2. FSU Manual Front
- 3. FSU Manual
FSU Manual Front
Fixed Subscriber Unit Installation Manual Table of Contents Proprietary Statement UTStarcom Inc. has prepared this manual for use by customers, UTStarcom personnel, and licensees. The information contained herein is the property of UTStarcom Inc. and shall neither be reproduced in whole nor in part without prior written approval from UTStarcom Inc. UTStarcom reserves the right to make changes without notice to the specifications and materials contained herein, and shall not be responsible for any damages caused by reliance on the material as presented, including, but not limited to, typographical, arithmetic, and listing errors. Trademarks All trademarks and service marks used in this document belong to their respective owners. Warranty and Return Policy Refer to the terms and conditions of the contract for warranty and return policy details. Customer Service Refer to the terms and conditions of the contract for customer service policy details, or call the local UTStarcom Facility. UTStarcom’s Facilities are listed below: U.S. Facilities and Operations UTStarcom, Inc. UTStarcom New Jersey R&D Center 1275 Harbor Bay Rd. Alameda, CA 94502, USA Tel. 510 864 8800 Fax 510 864 8802 33 Wood Avenue South 8th floor Iselin, NJ 08830 Tel. 732 767 5200 Fax 732 548 1099 China Facilities and Operations UTStarcom (China) Ltd. 4th Floor A&B, Beijing FuHua Tower No. 8 Chao Yang Men Bei Da Jie, Dong Cheng District, Beijing, 100027 P.R. China Tel 86-10-6554-2030 Fax 86-10- 6554-2058 UTStarcom, Shanghai Office Zhejiang Unitel Telecommunications Equipment Ltd 3/4F Building 3 Yile Industrial Park 129 Wenyi Rd. Hangzhou, 310012, P.R. China Tel. 86-571-886-2314 Fax 86-571-886-2349 Guang Dong UTStarcom Co. Ltd. Release 1.00 10/03/97 Airstar-Wireless Local Loop ii Table of Contents Fixed Subscriber Unit Installation Manual 245 Tianping Rd. Jinguo Garden 803 Shanghai, 200030, P.R. China Tel. 86-21-6433-6223 Fax 86-21-6433-6226 4 Yunshan Road East, North River Yunshan Industry Zone Huizhou, Guangdong 516001, P.R. China Tel. 86-752-280-8868 or 86-752-280-8818 Fax 86-20-280-8838 UST Guangdong Subsidiary Nantian UTStarcom Inc. 352 Tianhe Road, 21F Guangdong, 510620, P.R. China Tel. 86-20-8758-4025 Fax 86-20-89753-7411 43 Tianmushan Rd. Hangzhou, 310007, P.R.China Tel. 86-571-2314 Fax 86-571-797-5149 UTStarcom (Hangzhou) Ltd. 118 Moganshan Rd. 2nd floor Hangzhou, 310005, P.R. China Tel. 86-571-880-0350 or 86-571-880-0369 Fax 86-571-805-6499 International Facilities and Operations UTStarcom, Singapore Office UTStarcom, India Office ACTEL Communications 141 Middle Road #06-02 GSM Building, Singapore 188976 Tel. 65-334-6602 Fax 65-334-6606 W.S. Telesystems Limited Dr. Brownamma Towers 11 Floor, 70/1, Mission Road Bangalore - 560 027, India Tel. 91-80-227-4444 Fax 91-80-222-5268 UTStarcom, Thailand Office For You Infosys Co., Ltd 47/15 Soi Lardprao 122 Bangkapi Bangkok 10310 Tel. 66-2-539-7140 or 66-2-934-0179 ext 80 Fax 66-2-539-7431 10/03/97 Release 1.00 Airstar-Wireless Local Loop Fixed Subscriber Unit Installation Manual Table of Contents iii WARNING! FCC RF EXPOSURE COMPLIANCE This PCS base station has been tested and complies with the Federal Communications Commission (FCC) RF exposure limits for General Population/Uncontrolled exposure environment. In addition, it complies with the following Standards and Guidelines: • FCC 96-326, Guidelines for Evaluating the Environmental Effects of RadioFrequency Radiation. • FCC OET Bulletin 65 Edition 01-01 (2001) Supplement C, Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields. • ANSI/IEEE C95.1-1992, IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. • ANSI/IEEE C95.3-1992, IEEE Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields - RF and Microwave. Antenna Installation Requirement: The antenna must be installed and located on a roof top site, pole, or building structure away from users and bystanders. It must be mounted in a manner to ensure that a minimum separation distance of 20cm is normally maintained between all users and bystanders. Important Safety Instructions • Read and follow all warning notices and instructions marked on the product or included in this document. • This product is intended to be used with a three-wire grounding type plug - a plug that has a grounding pin. This is a safety feature. Equipment grounding is vital to ensure safe operation. Do not defeat the purpose of the grounding type plug by modifying the plug or using an adapter. Prior to installation, use an outlet tester or voltmeter to check AC receptacle for the presence of earth ground. If the receptacle is not properly grounded, the installation must not continue until a qualified electrician can determine another method of grounding the equipment. • Do not allow anything to rest on the power or line cords and do not located the product where the power or line cords could be stepped on. • This product must be serviced only by a qualified service technician. • Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the customer. Release 1.00 10/03/97 Airstar-Wireless Local Loop iv Table of Contents Fixed Subscriber Unit Installation Manual • When installed in the final configuration, the product must comply with the applicable safety standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance. • A rare phenomenon can create a voltage potential between the earth grounds of two or more locations. If products installed in separate locations are interconnected, the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the products. • Install this product in a location protected from humidity, dust, and extreme heat. This will ensure that internal parts are not damaged. If liquids are spilled on the product, contact a qualified service technician. • Use this product only with UTStarcom approved or recommended adapters and batteries. • Do not attempt to remove the cover. Contact a qualified service technician for servicing the product. 10/03/97 Release 1.00 Airstar-Wireless Local Loop Fixed Subscriber Unit Installation Manual Table of Contents CONTENTS 1. INTRODUCTION TO THIS MANUAL .................................................................................................................. 1-1 1.1 ORGANIZATION ........................................................................................................................................................1-1 2. GENERAL DESCRIPTION ...................................................................................................................................... 2-3 2.1 OUTGOING CALLS.....................................................................................................................................................2-4 2.2 INCOMING CALL.......................................................................................................................................................2-5 2.3 AUTHENTICATION ....................................................................................................................................................2-6 2.4 HOOKING SIGNAL TRANSMISSION ............................................................................................................................2-7 3. SYSTEM CONSTRUCTION..................................................................................................................................... 3-9 4. INSTALLATION INSTRUCTIONS....................................................................................................................... 4-11 4.1 BEFORE BEGINNING ...............................................................................................................................................4-11 4.1.1 Plan FSU Configuration .............................................................................................................................. 4-12 4.1.2 Antenna Orientation..................................................................................................................................... 4-12 4.1.3 Antenna Type Determination Guidelines ..................................................................................................... 4-13 4.1.4 Main Unit Site Selection............................................................................................................................... 4-13 4.1.5 Installation Accessories, Standard and Special Tools ................................................................................. 4-14 4.2 FSU CONFIGURATION INSTRUCTIONS ....................................................................................................................4-15 4.3 COAXIAL CABLE INSTALLATION.............................................................................................................................4-18 4.4 ANTENNA INSTALLATION .......................................................................................................................................4-20 4.5 MAIN UNIT INSTALLATION .....................................................................................................................................4-24 4.6 ANTENNA ORIENTATION ADJUSTMENT ..................................................................................................................4-31 5. ACRONYM AND ABBREVIATION LIST ........................................................................................................... 5-33 APPENDIX A : SPECIFICATIONS.............................................................................................................................A-1 FIGURES FIGURE 2-1 : OVERVIEW OF FSU IN AIRSTAR-WLL SYSTEM .............................................................................................2-2 FIGURE 2-2 : OUTGOING CALL............................................................................................................................................2-3 FIGURE 2-3 : INCOMING CALLS...........................................................................................................................................2-4 FIGURE 2-4 : AUTHENTICATION ..........................................................................................................................................2-6 FIGURE 3-1 : FSU - MAIN UNIT ..........................................................................................................................................3-7 FIGURE 4-1 : FSU INSTALLATION FLOW CHART .................................................................................................................4-9 FIGURE 4-2 : FSUJ MENU ................................................................................................................................................4-14 FIGURE 4-3 : WLLSO SETUP SCREEN WITHOUT CONFIGURATION DATA .........................................................................4-15 FIGURE 4-4 : WLLSO SETUP SCREEN WITH CONFIGURATION DATA ...............................................................................4-16 FIGURE 4-5 : STRIPPED COAXIAL CABLE ..........................................................................................................................4-17 FIGURE 4-6 : FSU ANTENNA AND ACCESSORIES ..............................................................................................................4-18 FIGURE 4-7 : ANTENNA BRACKET ASSEMBLY ..................................................................................................................4-19 FIGURE 4-8 : ANTENNA MOUNTED ON POLE ....................................................................................................................4-20 FIGURE 4-9 : EATH CABLE CONNECTION ..........................................................................................................................4-21 FIGURE 4-10 : COAXIAL CABLE CONNECTION TO ANTENNA.............................................................................................4-22 FIGURE 4-11 : FSU AND ACCESSORIES.............................................................................................................................4-23 FIGURE 4-12 : ANTENNA CABLE CONNECTION .................................................................................................................4-24 FIGURE 4-13 : TELEPHONE CORD CONNECTION ...............................................................................................................4-25 FIGURE 4-14 : BACKUP BATTERY UNIT CONNECTION ......................................................................................................4-26 FIGURE 4-15 : AC/DC ADAPTER CONNECTION ................................................................................................................4-27 FIGURE 4-16 : AC OUTLET CONNECTION .........................................................................................................................4-28 FIGURE 4-17 : WALL MOUNTING ......................................................................................................................................4-29 FIGURE 4-18 : FIXED SUBSCRIBER UNIT CONFIGURATION ................................................................................................4-30 Release 1.00 10/03/97 Airstar-Wireless Local Loop vi Table of Contents Fixed Subscriber Unit Installation Manual TABLES TABLE 4-1 : ANTENNA TYPE DETERMINATION GUIDELINES .............................................................................................4-11 TABLE A-1 : FSU SPECIFICATIONS ....................................................................................................................................A-3 10/03/97 Release 1.00 Airstar-Wireless Local Loop
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Producer : Acrobat Distiller 4.05 for Windows Creator : Microsoft Word 9.0 Modify Date : 2001:09:06 17:33:23-04:00 Author : Valued Gateway 2000 Customer Title : WARNING! FCC RF EXPOSURE COMPLIANCE. Create Date : 2001:09:06 17:33:07 Page Count : 6 Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools