UTT TECHNOLOGIES REG08-UTT ACCESS POINT User Manual
SHANGHAI UTT TECHNOLOGIES CO., LTD. ACCESS POINT
User Manual
Thank you for choosing the UTT Ceiling Mount Wireless Access Point (hereinafter as “Device"). The UTT WA Series Ceiling Mount AP is a best-in-class indoor Access Point specifically designed for business-class wireless network such as hotel, cafe, lounge, shopping mall, restaurant and school. The available models are WA1700N, WA1900N, WA2200N, WA2500N and etc. With a standard install design and stylish appearance, the Device can be installed on wall or ceiling without hassle. Powered with integrated 802.3af Power over Ethernet standard (passive PoE for WA1700N), it allows installation in areas where power outlets are not readily available. The Device can also be managed by UTT WX Series WiFi Controller when working in FIT Mode. The WX Series WiFi Controller User Guides are available for download at www.uttglobal.com/download/. Ceiling Mount Wireless Access Point This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. PoE Module (Optional) —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. SN: 0902-0001-005 Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. LED/Button/Interface WLAN After the Device is powered on and wireless enabled, the WLAN LED indicator will blink when transmitting/receiving wireless data. Link/Act When a device is connected to a port properly, the port’s corresponding LED indicator will be on. The indicator will blink when there’s traffic on that port. SYS The LED indicator blinks twice per second when the system is operating properly, and it will blink slower if the system is under heavy load. Reset With the Device powered on, press the Reset button with a bent paperclip for 5 seconds until the WLAN LED indicator goes off, and then release the button. After that, the AP will restart itself and reset the device to factory default settings. LAN The LAN interfaces provide a LAN connection to network devices, such as PCs or switches. PoE You may use this Ethernet interface to power the Device. Power can be provided by an UTT PoE Switch or a 802.3af PoE injector. Power 2.4G 5G Support Description The Power interface is where you connect the provided power adapter. The 2.4G LED indicator is on when 2.4GHz Wireless is enabled. The LED indicator blinks when transmitting/receiving 2.4G wireless data. The 5G LED indicator is on when 5GHz Wireless is enabled. The LED indicator blinks when transmitting/receiving 5G wireless data. Place the mounting bracket in the center of the ceiling tile. Mark the mounting screw holes and 25 mm hole for the Ethernet cable. Use a drill bit to drill the screw holes, and cut or drill the 25 mm hole for the Ethernet cable feed. Secure the Mounting Bracket to the ceiling tile by using the Expansion Bolts. Then feed the Ethernet cable through the 25 mm hole. Connect the Ethernet cable to the Ethernet port of the Device. NOTE: 1. Please assign your computer a static IP address within the same range as the Device’s IP address (192.168.1.253 by default). See more on Appendix: Computer Configuration. 2. If there is DHCP server on the local area network, the Device will obtain an IP address automatically. Launch a web brouser, such as Internet Explorer or Mozilla Firefox. In the Address field enter the Device’s IP Address (192.168.1.253) and press the Enter key. Align the notch on the Device with the notch on the mounting bracket. Turn the Device clockwise untill it locks into place. NOTE: The Device works in FIT AP Mode by default. You can go to “Start Device Mode” to change the Device Mode to FAT AP Mode. Select “Use the following IP address”, enter the static IP address ( a free IP address in 192.168.1.0/24) in IP address field, 255.255.255.0 in Subnet mask field, and enter the IP address of your default gateway in Default Gateway field. Click “OK” to finish the configuration. Enter the default user name of admin and password of admin in the User Name and Password fields. Click “OK” to access the Device’s Web GUI. Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-701 Format : application/pdf Title : 0902-0001-005 Ceiling Mount Wireless Access Point Quick Start Guide Metadata Date : 2016:07:19 16:00:04+08:00 Modify Date : 2016:07:19 16:00:04+08:00 Create Date : 2016:01:08 12:56:12+09:00 Creator Tool : Adobe Illustrator CS6 (Windows) Thumbnail Width : 256 Thumbnail Height : 100 Thumbnail Format : JPEG Thumbnail Image : (Binary data 9123 bytes, use -b option to extract) Instance ID : uuid:bcad09e1-85b4-4dbe-8e74-af8731614c08 Document ID : xmp.did:D4027F18C1B5E511A590A553B45CDE43 Original Document ID : uuid:5D20892493BFDB11914A8590D31508C8 Rendition Class : proof:pdf Derived From Instance ID : uuid:c54bebde-49db-4bcf-a9b0-981ff646681f Derived From Document ID : xmp.did:79D9A96681B3E511A174EABD67EAFD9A Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8 Derived From Rendition Class : proof:pdf History Action : saved, saved History Instance ID : xmp.iid:275D04A7E012E411857B9315B6D856A7, xmp.iid:D4027F18C1B5E511A590A553B45CDE43 History When : 2014:07:24 12:03:32+08:00, 2016:01:08 12:56:08+08:00 History Software Agent : Adobe Illustrator CS5, Adobe Illustrator CS6 (Windows) History Changed : /, / Manifest Link Form : EmbedByReference Manifest Reference File Path : C:\Documents and Settings\huang.qinglan\桌面\未标题-1.png Startup Profile : Print Has Visible Overprint : False Has Visible Transparency : True N Pages : 1 Max Page Size W : 426.000526 Max Page Size H : 290.999809 Max Page Size Unit : Millimeters Font Name : ArialMT, Arial-BoldMT, ArialRoundedMTBold, Arial-ItalicMT Font Family : Arial, Arial, Arial Rounded MT Bold, Arial ItalicMT Font Face : Regular, Bold, Regular, ItalicMT Font Type : Open Type, Open Type, Open Type, Unknown Font Version : Version 5.01.2x, Version 5.01.2x, Version 1.51, 001.001 Font Composite : False, False, False, False Font File Name : Arial.ttf, Arial Bold.ttf, ARLRDBD.TTF, wmr_____.pfb; wmr_____.pfm Plate Names : Cyan, Magenta, Yellow, Black Swatch Groups Colorants Tint : 100.000000 Swatch Groups Group Name : 鲜艳 Swatch Groups Group Type : 1 Swatch Groups Colorants Swatch Name: C=60 M=90 Y=0 K=0 Swatch Groups Colorants Mode : CMYK Swatch Groups Colorants Type : PROCESS Swatch Groups Colorants Cyan : 60.000002 Swatch Groups Colorants Magenta : 90.000004 Swatch Groups Colorants Yellow : 0.003099 Swatch Groups Colorants Black : 0.003099 Producer : Adobe PDF library 10.01 Page Count : 3 Container Version : 11 Creator Version : 16 Creator : Adobe Illustrator(R) 16.0 For : ˫, Bounding Box : 0 -895 2436 32EXIF Metadata provided by EXIF.tools