Ubiquiti M5 Outdoor M5 User Manual user guide

Ubiquiti Networks, Inc. Outdoor M5 user guide

Contents

Users Manual

Download: Ubiquiti M5 Outdoor M5 User Manual user guide
Mirror Download [FCC.gov]Ubiquiti M5 Outdoor M5 User Manual user guide
Document ID3107185
Application IDVba6iTAllgYgvL6glMf73A==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize112.79kB (1409820 bits)
Date Submitted2016-08-22 00:00:00
Date Available2016-08-22 00:00:00
Creation Date2009-07-16 17:41:20
Producing SoftwareMac OS X 10.5.6 Quartz PDFContext
Document Lastmod2016-08-11 13:39:23
Document Titleuser guide
Document CreatorOmniGraffle Professional
Document Author: Robert Pera

M5
OEM Users Guide
TECH SPECS
SYSTEM INFORMATION
Processor Specs
Memory Information
Networking Interface
Atheros MIPS 24KC, 400MHz
64MB SDRAM, 8MB Flash
1 X 10/100 BASE-TX (Cat. 5, RJ-45) Ethernet Interface
REGULATORY / COMPLIANCE INFORMATION
MCS0
MCS1
MCS2
MCS3
MCS4
MCS5
MCS6
MCS7
MCS8
MCS9
MCS10
MCS11
MCS12
MCS13
MCS14
MCS15
OPERATING FREQUENCY
SPECIFICATIONS
Avg. TX
Tolerance
27 dBm
+/-2dB
25 dBm
+/-2dB
23 dBm
+/-2dB
22 dBm
+/-2dB
27
27
27
27
26
24
22
21
27
27
27
27
26
24
22
21
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
5745MHz-5825MHz
5GHz RX SPECIFICATIONS
DataRate
Sensitivity
Tolerance
24Mbps
-83 dBm
+/-2dB
36Mbps
-80 dBm
+/-2dB
48Mbps
-77 dBm
+/-2dB
54Mbps
-75 dBm
+/-2dB
11a
5GHz TX POWER
DataRate
1-24Mbps
36Mbps
48Mbps
54Mbps
FCC Part 15.247, IC RS210, CE
YES
5GHz 11n
5GHz 11n
11a
Wireless Approvals
RoHS Compliance
MCS0
MCS1
MCS2
MCS3
MCS4
MCS5
MCS6
MCS7
MCS8
MCS9
MCS10
MCS11
MCS12
MCS13
MCS14
MCS15
-96
-95
-92
-90
-86
-83
-77
-74
-95
-93
-90
-87
-84
-79
-78
-75
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
+/-2dB
PHYSICAL / ELECTRICAL / ENVIRONMENTAL
Enclosure Size
Weight
Enclosure Characteristics
Mounting Kit
Max Power Consumption
Power Supply
Power Method
Operating Temperature
Operating Humidity
Shock and Vibration
16cm length x 8cm width x 3cm height
0.5 kg
Outdoor UV Stabalized Plastic
Pole Mounting Kit included
6.5 Watts
24V, 1A POE Supply Included
Passive Power over Ethernet (pairs 4,5+; 7,8 return)
-30C to 75C
5 to 95% Condensing
ETSI300-019-1.4
COMPLIANCE INFORMATION
FCC
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to pro-vide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the
interference at his own expense.
The antennas used for this transmitter must be installed to provide a separation
distance of at least 252cm from all persons and must not be located or
operating in conjunction with any other antenna or transmitter.
INDUSTRY CANADA
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du
Canada.
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
To reduce potential radio interference to other users, the antenna type and its
gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.)
is not more than that permitted for successful communication.
This equipment is required to be professionally installed
The device has been designed to operate with the antennas listed below and having a
maximum gain of 30dBi. Antennas not included in this list or having a gain greater than
30dBi are strictly prohibited for use with this device. The required antenna impedance is
50 ohms
2x2 Point-To-Point Use
Ubiquiti RD-5G-30
Ubiquiti RP-5G-24
Ubiquiti AMS-5G-20
1x1 Point-To-Point Use
Ubiquiti AG-5G-30
2x2 Point-To-MultiPoitn Use
Ubiquiti O-5G-7
Operation is restricted to Point-To-Point use for antenass other than the Ubiquiti O-5G-7
listed above.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Apple Keywords                  : 
Author                          : Robert Pera
Create Date                     : 2009:07:16 17:41:20Z
Modify Date                     : 2016:08:11 13:39:23-07:00
Subject                         : 
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Format                          : application/pdf
Creator                         : Robert Pera
Description                     : 
Title                           : user guide
Creator Tool                    : OmniGraffle Professional
Metadata Date                   : 2016:08:11 13:39:23-07:00
Keywords                        : 
Producer                        : Mac OS X 10.5.6 Quartz PDFContext
Document ID                     : uuid:342199bd-e402-4d38-a842-95140420feb8
Instance ID                     : uuid:cdf58fec-fd4b-4768-a2be-9c8693c4acff
Page Count                      : 3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SWX-M5

Navigation menu