UltraVision Security Systems CMD2A-F2 ultrawideband surveillance system User Manual UltraSensor manual 2 17 09

UltraVision Security Systems, Inc. ultrawideband surveillance system UltraSensor manual 2 17 09

User Manual

   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 1UltraSensor   Security System User Manual  Table of Contents  Product Overview..........................................................................................................................................................2 Server-24.......................................................................................................................................................................4 Server-8.........................................................................................................................................................................5 USB connection ...................................................................................................................................................6 Ethernet connection .............................................................................................................................................6 Installation Guide ..........................................................................................................................................................7 Ethernet Cable Installation...................................................................................................................................7 CMD Cable Assembly .......................................................................................................................................11 Wire Diagram ....................................................................................................................................................12 Configuration Manager Software................................................................................................................................14 Start-up ..............................................................................................................................................................14 Create /Edit Users..............................................................................................................................................16 Change Password...............................................................................................................................................17 Delete User ........................................................................................................................................................17 Configure Sensors..............................................................................................................................................18 Delete a sensor...................................................................................................................................................19 Configure System ..............................................................................................................................................20 Set Map Scale ....................................................................................................................................................21 Configure Sensor using Monitor Screen............................................................................................................21 Configure Contacts ............................................................................................................................................22 Contact Closure Detail.......................................................................................................................................23 Monitor Screen ..................................................................................................................................................23 View Log File....................................................................................................................................................25 Configure Alarm Mass Threshold (Sensitivity).................................................................................................26 Logout................................................................................................................................................................26 Software Updates...............................................................................................................................................26 Sensor Specifications...................................................................................................................................................27 Integrating the CMD-Server 24 with your network.....................................................................................................28 Changing the CMD-Server IP address...............................................................................................................28 Accessing the CMD-Server over a WAN..........................................................................................................29 Integrating the CMD-Server 8 with your network.......................................................................................................30 Changing the CMD Server-8 IP address............................................................................................................30 Accessing the CMD-Server over a WAN..........................................................................................................30 Remote Switch Device................................................................................................................................................32 Installation .........................................................................................................................................................32 Running the Application....................................................................................................................................33 Removing the Application .................................................................................................................................35 Dry contact switch specifications for Server-8............................................................................................................36 Dry contact switch specifications for Server-24..........................................................................................................37 Problem Solving..........................................................................................................................................................38 Install MS .NET framework and Java .........................................................................................................................39 Allow a remote PC to fully communicate with a Server-8..........................................................................................40 Release 10.9 Notes ......................................................................................................................................................41 Upgrade Process ................................................................................................................................................41 Graphical User Interface (GUI) Changes...........................................................................................................41 Server Changes ..................................................................................................................................................42 Technical Support........................................................................................................................................................44 Contact information.....................................................................................................................................................44 ®
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 2 Product Overview   The CMD-2 motion sensor can be used in a wide variety of applications. The primary purpose of the sensor is to detect motion and provide additional information about the moving target. The sensor is designed to take advantage of one of the primary features of its technology, which is its ability to see through earth, concrete and other standard building materials. Other motion sensors need a window onto the world, the CMD-2 does not, and it can be completely buried where it is protected from tampering and from the environment.  One application of the CMD-2 is to protect buildings and premises from entry by unknown persons or vehicles. Used in conjunction with CCTV systems the CMD-2 can establish a powerful barrier to identify and track unknown intruders long before they enter a building. Sensors may be placed almost one quarter mile from the security center, giving the phrase ‘detection beyond the fence’, whole new meaning. Longer distances are possible with fiber optic or wireless Ethernet connection. Because the CMD-2 is buried, intruders cannot see or disable the sensor. False alarms are minimal.  The sensor can be buried up to eight inches beneath the surface of earth, roads or walkways. The material covering the sensor can be concrete, granite, earth, bricks, etc. The only limitation is that the sensor cannot be covered with sheet metal or a dense metal mesh material.  The radial range of the sensor is 22 to 25 feet (6.5 to 8 meters) and it covers an elliptical pattern on the ground (or approximates a hemisphere in 3D). It is able to detect motion from any direction. Therefore with a fifty foot diameter of coverage multiple sensors can form a ring or fence around a facility. When a sensor detects motion an alarm signal is generated and recorded. As an option, a designated CCTV camera can point in the direction of that sensor and record the target and its activity.  Each sensor is powered through its Ethernet connection (standard CAT-5 burial cable). The connecting cable from the sensor to a concentrator box (CB-06) and then to the server can be up to 400 feet (123 M) long. Longer cable distances requires daisy-chaining concentrator boxes (CB-06). Up to four concentrator boxes can be daisy chained resulting in a total cable distance from server to sensor of 1200 feet (393M). A separate power cable is required for daisy-chained concentrator boxes (hubs). See the attached diagrams for these two connection methods. Note that Ethernet has a limitation of 300 feet (91 meters)maximum between hubs. The use of remote power sources can increase the distance to any desired range.   The two connection methods of daisy-chain and direct connection can be used together in a single security system. The limitations are defined by the number of sensors that can be powered by the server. Three standard servers are available; they are designed to control, monitor and power up to 8, 24 and 48 CMD sensors. Custom systems can be designed as required.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 3The following diagram shows how these sensors are buried in a typical installation. Signal and power to the sensor is supplied from a buried Ethernet wire which goes to the server at the security command and control console. A hole is dug approximately 18 inches by 18 inches (45cm x 45cm) by about eighteen inches (45 cm) deep. A four inch (10 cm) layer of sand is placed in the hole and the sensor is placed on top of the sand. The sensor is then covered with sand about one inch 2.5 cm) deep. Earth (topsoil) is then used to fill the hole completely or if the sensor is under pavement then asphalt or concrete is used to fill the hole to the existing grade. Note that highly conductive soils such as wet clay covering the sensor can reduce the detection range.                                                                  The sensor can be wall mounted                                                                as shown.           The resulting side view of the installation complete with detection field is shown (right).The detection hemisphere has a diameter of 50 feet (15m).
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 4In very cold regions or where clay soils may prohibit drainage of water from the CMD installation, then holes should be drilled another two feet into the soil and then filled with pea gravel to permit better drainage. This type of installation will also provide better protection from freeze-thaw cycles over time.    Server-24   The CMD Server box provides the power and Ethernet connections to the CMD sensors. Up to 24 sensors can be connected to and powered from the basic server (shown below). Other servers are available with additional capacity and dry switches. Dry contact connections are provided for each sensor so that alarms can be turned on and/or CCTV camera presets can be utilized. The server also provides the gateway to the security network - and the Internet. It is lockable and made of steel, designed for wall mounted applications.   The server logs all alarms and monitors the sensor ‘heartbeat’ to insure each one is working. The internet connection allows users with the proper password to access the information from any location.   The following diagram shows the primary connections that can be made to the Server.  AC Power Direct Connections (4)Daisy Chain Connections (2) Dry Switch Connections (24) Internet Connection
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 5Server-8   The CMD Server-8 is a laptop computer system that connects up to 8 sensors to collect and log data. This version of the Server is more compact and appropriate for smaller security installations. The CMD Server-8 includes a laptop with all the software needed to run the system.    Front view     Back view  Dry switch contacts- 8 sets
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 6  USB connection   Ethernet connection
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 7Installation Guide  Ethernet Cable Installation  Standard CAT5 Ethernet cable is used to make all connections from the sensors to the concentrator boxes and from the concentrator boxes to the Server.    Buriable Ethernet cable should be used in all cases where conduit is not available. This type of cable is rugged, waterproof and rodent proof.  If conduit is available then CAT5 plenum Ethernet cable can be used. Plenum cable has solid wires which carry the signal and power over longer distances than stranded wire cables. Note that when installing the solid wire plenum cable it is very important not to get kinks in the cable. The cable should be carefully unrolled during installation. Kinks in the wire can cause breaks and internal signal reflections which will degrade the signal from the sensor.  The Ethernet cable may be buried at any depth desired. Typically the depth should be 3 to 4 inches (8 to 10 cm) to avoid most problems that may come from changes to the ground surface. In addition to trenching there are specialized tools to make cable installation fast and less disruptive to the ground surface. Companies who install fiber optic cable for Internet applications have this equipment.  Typically once the cable run length is measured it is best to add another 5% to the measured length. This extra distance will take care of small variations that might have been missed.   The following diagram shows the direct connection method of connecting Concentrator hubs to the Server and defined cable length limitations. Cable length limits are due to Ethernet transmission limits and power transmission limits.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 8  SERVER and system CB-06 to CMD Max distance 67m Concentrator Box Connect 1 to 6 CMDs  CB-06 to CMD Max distance 67m Server to  CB-06Server to  CB-06Concentrator BoxNetworkor InternetLaptopCB-06 CMD NOTES: Each UltraSensor (CMD) has a separate Ethernet cable that connects it to the CB-06 Concentrator Box. Power is supplied through the Ethernet cable. Each Concentrator Box (CB-06) has a separate Ethernet cable that connects it directly to the SERVER and power, all through the Ethernet cable (POE). The SERVER also has a dry switch output (twisted pair) for each CMD sensor  A maximum of 6 CB-06 boxes and 24 CMD may be connected. (8 CMDs max for Server8) Maximum cumulative cable distance from the SERVER to any CMD sensor is 150m (465 feet) Wireless and F/O may be used in place of Ethernet cable . Power is then supplied from an indirect source.  UltraSensor™  Security system using direct connection to each concentrator box Dry switch output for each CMD CB06 CMD  CMD  CMD  CMD  CMD CMD  CMD  CMD  CMD  CMD CMD
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 9 Server to CB-06 SERVER  and system powerCB-06 to  CB-06 CB-06 to  CB-06 CB-06 to  CB-06 UltraSensor™  Security system using daisy-chain connection of concentrator boxes Laptop CB-06 Networkor InternetNOTES: Each UltraSensor (CMD) has a separate Ethernet cable that connects it to the CB-06 Concentrator Box. Power is supplied through the Ethernet cable (POE). Each Concentrator Box (CB-06) has a separate Ethernet cable AND a power cable (both parallel cables shown by dashed line) that connects it to another CB-06 Box and finally to the SERVER and Power The SERVER also has a dry switch output (twisted pair) for each CMD sensor. A maximum of 4 CB-06 Boxes can be in a single daisy-chain from the SERVE . Maximum cumulative cable distance from the SERVER to any CMD sensor is 1,200 feet (390m). CB-06 CB-06 CB-06CB-06 to CMD Max distance 67m CB-06 to CMD Max distance 67m CMDsConnect 0 to 6 CMD sensors Connect 0 to 6 CMD sensors Connect 0 to 6 CMD sensors Connect 1 to 6 CMD sensors Dry switch output for each CMD CMDsCMDsCMDs
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 10 The diagram above shows a typical installation and how the devices are connected. The devices colored blue are supplied by UltraVision. The units shown are:  • CMD motion sensors (21) • Concentrator Hubs (4) • CMD Server (1)  A Concentrator hub can have up to six sensors connected. Servers are available in three standard sizes;  1. CMD Laptop Server can have up to two hubs connected and a maximum of 8 sensors all direct connected.  2. CMD Server 24 can deploy 24 sensors. 3. CMD Server 48 can deploy 48 sensors.  4. Servers can be customized depending upon customer requirements.  The above limits are defined by power limits supplied through the server. When power is supplied from independent sources, the sensor limit for each server is 250. Dry switches may be added as required.   The dry switch outputs from the server can be connected to CCTV cameras in order to drive them to their preset locations. The dry switch outputs can also be used to sound alarms, turn on lighting and perform any other operation required in a standard security system.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 11   CMD Cable Assembly   Cable is not supplied. Please follow the recommended specifications when sourcing the cable.   Cable Specifications:  Direct burial  Direct burial, plenum CAT 5 or better grade, at least 4 twisted pairs Protected burial (conduit)  CAT 5 or better plenum, at least 4 twisted pairs Power cable  16 gauge, 3 conductor, shielded direct-burial (ref #8302S)  Tools:   Follow manufacturer’s instructions for assembling and using the DMC crimping tool M22520/1-01 and turret M22520/1-02. Set up tool for gauge of wire and pins being used. For the most common 24 gauge wire, position turret for 20 (red cylinder) and black wire size dial to 24.   To attach 9 pin Clipper connectors to cable ends:  1. Strip off approx 50mm (2”) of cable’s outer jacket.  2. Take note of wire colors and twisted pairs. Note: Your cable will have its own color combinations. What is important is that it is wired the same on both ends and twisted pairs stay together. 3. The backshell comes in 3 pieces, all in one bag. Assemble the two major pieces together (they can only join one way) placing the washer between them. Tighten firmly.        Excess force will distort the washer. 4. Feed the cable through the assembled backshell, entering the compression nut end. 5. Strip off 4mm (5/32) of each wire. Place a pin into the hole of the crimping tool on the side that has the yellow OSHA sticker. Insert a stripped wire into the pin.  6. Squeeze the handles of the crimping tool noting that it has a ratchet action. You must complete the crimping action all the way so the handle will release. Repeat steps 5 & 6 for all 8 wires. 7. Release the red section from the black section of the Clipper connector by referring to the Clipper Assembly instructions (Page 16).                                                                        8.  The 2 pieces do not need to be fully separated, just the red part slightly extracted. 9. Insert pins noting the pin numbering/labeling on the red section
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 12 Wire Diagram       CB – Server        CB - CMD       Twisted Pairs    UVSS cable color           ETXD-P       ETXD-P     1 ------------------------------------- 1  White/Orange ETXD-N  ETXD-N    2 ------------------------------------- 2       Orange  ERXD-P  ERXD-P     3 ------------------------------------- 3  White/Green ERXD-N  ERXD-N    4 ------------------------------------- 4       Green    48-55V    RELAY-0     5 ----------------------------------- 5  White/Blue 48-55V    RELAY-1     6 ----------------------------------- 6        Blue  GND    12-15V         7 ----------------------------------- 7  White/Brown GND    GND             8 ----------------------------------- 8      Brown          9 ----------- Not Used ----------- 9  Power Wire Diagram (for daisy-chained concentrator boxes)  48-55V  Pos         1----------------------------------------1   Red 48-55V  Neg        2----------------------------------------2   Black GND        3----------------------------------------3   Blue Shield      4----------------------------------------4   Shield  10. Squeeze tabs and return red section into black. 11. Screw backshell onto connector. It may be easier to temporarily connect to a CMD box while installing the backshell. 12. Tighten compression nut of backshell to complete Clipper connector installation.  13. Using a multimeter or similar device, verify continuity of cable. Pin 1 of one end connects to pin one of the other end, pin 2 to 2, pin 3 to 3, etc. Since the pins are not clearly numbered on the Clipper connector, it is helpful to use the inner keyed tabs surrounding the pin holes or the one indented pin for a reference.  If CB to CMD exceeds 110’/33m, crimp the pin 5 wire (wht/blu) with pin 7 (wht/brn), then crimp the pin 6 wire (blu) with pin 8 (brn) at both ends. Do not use pins 5 and 6.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 13
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 14Configuration Manager Software   The configuration and operational software and user screens are the same for all server types.   The UVSS UltraSensor Configuration Manager Software/Laptop Server is capable of powering, configuring, and monitoring up to eight UltraSensors and two Concentrator Boxes. (If more than 8 relay contacts are required, a FGRMA24 should be used in place of a FGRMA8.) Prior to powering up any equipment, please make sure that all System components have been properly installed and connections made. Please note the following:  • If two Concentrator Boxes are used in the System, any combination of UltraSensors may be mixed on either Concentrator Box. Up to six Sensors are managed by one Concentrator Box. • To return to the Windows desktop while the UltraSensor software is running, you can minimize the UltraSensor program by pressing the Windows flag icon and “D” simultaneously.  • If the graphic map of your facility did not come pre-installed, create a jpg image file of the facility and save it to c: Inetpub\wwwroot\Images. Recommended image size is 460 x 680 pixels/inch.   Start-up  1. After all connections are made, power up the CMD Server-8 module (black box), using the power switch on the front of the unit; then turn on the laptop. Upon laptop power up, double-click the UltraVision icon to enable Windows XP loading. In the Windows Start Menu or Desktop, select Digi Discovery. Verify all sensor IP’s are present. (Sensors take 30 seconds to appear after powered on) Check cables and connections if any are missing. Close Digi Discovery when finished.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 15 2. Double-click the Internet Explorer icon on the  desktop. You may see a Certificate Error page  pop up. If that happens, simply click  “Continue to this website…”      3. On the Log-in screen, User is Admin and the password is generic11.. (The password is the word generic, the numeral 1 twice and a period twice.) Additional users may be added and password changed after initial log-in. Left click Log-in.             User name: admin  Password: generic11..
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 16Create /Edit Users  1. Upon successful log-in, the Option Menu will be displayed. Select Setup Users.     2. This page is used to change password or add a new user. Select New User to add a user.     Select  Setup Users
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 17  3. Select Administrator or Guard. [Guard will have access only to the Monitor Screen and Event log. Administrator can add/delete Users, configure Sensors and View Log File.] 4. Type in the new User Name, their Password, repeated in Confirm Password.  Passwords must have at least seven characters with at least one non-alpha-numeric. 5. Select Create User. 6. Configuration Manager will confirm that User has been successfully added. 7. Click Continue to return to Create User screen. Continue to add Users or, if finished, select another screen from the menu on the left. Change Password  1. Password change may only be done by Administrator-level users and it is done through the Setup Users menu selection. 2. Select User from dropdown list.  3. Enter old password 4. Enter new password. Password parameters must be at least seven characters and at least one non-alpha-numeric character. Confirm password by re-typing.   5. Click Update. Delete User 1. In the setup user screen, select the user in the pull down list to be deleted.  2. Click the Delete User button.  3. A confirmation page will open.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 18Configure Sensors  1. From Menu Screen, click Configure Sensors. 2. From the drop down box at the top of the screen, select the number of the Sensor to be configured. The Sensor number is the last digit of the Sensor IP address.      (ex. 10.10.101.25 is sensor #25)    3. Enter the text Description of the Sensor (e.g., north walkway, front garden, southwest perimeter, etc.)  4. Select either Wall or Ground for Mounting Location.  5. Correct IP address will be automatically entered by the System. 6. Select Schedule Mode. Using drop down box select timed settings for this sensor or “always on” as default.  a. Use DEFAULT Settings AT ALL TIMES (ignore schedule) i. For Scanning Status, Select Enabled. ii. Enter Alarm Range Threshold. [Minimum 5 foot/1.5 meter, maximum 25 feet/ 7.6 meters.] iii. Enter Alarm Mass Threshold. [A setting of 1 will detect all possible motion, 255 the least. 60-75 is a “normal” setting.]  iv. Click Apply.  Message asks to confirm this step, if correct click “Yes.” v. Repeat procedure for additional sensors b. Use ALTERNATE settings as SCHEDULED, otherwise DEFAULT i. Select Enable and set alarm range threshold and alarm mass threshold as above.  ii. Click Apply, then Yes to confirm.  iii. Return to Configure page for same sensor and select Edit Schedule. Note: Select Alternate schedule mode and Apply before edit schedule.  iv. Use the Alternate settings table so turn sensors on and off to a schedule.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 19v. Using the appropriate drop down boxes set the Start Hour and Minute and the Stop Hour and Minute. Setting can cross midnight – i.e. 11 PM Monday evening Start and 3 AM Tuesday morning Stop.  vi. Enter the Alternate Scanning status, Alternate Alarm Range Threshold and Alternate Alarm Mass Threshold to be applied to the Alternate Schedule table. Apply.    Delete a sensor  1. To delete a configured sensor, change the scanning status to Disabled. 2. Click Apply. 3. Delete Sensor button is now active. Click to delete selected sensor.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 20Configure System      1. Select Configure System. 2. Assign a Site name.  3. Load the Site plan image. Use the browse button to locate a .jpg image of your site.As noted in the startup section, a site plan image file should be saved to the computer in the default file location:  c:\Inetpub\wwwroot\images.  4. Global Sensor Mode a. Use sensor settings – Uses individual sensor settings b. Enable all sensors – Turn on all sensors c. Disable all sensors – Turn off all sensors d. Use Master schedule – Use the master schedule to control the sensors 5. Select Units of measurement – English (standard US feet) or Metric (meters).  6. Select Alarm Logging Options – twice per second or once per incident.  a. Choosing once per incident will display and log sensor activity upon state change only. After activation, if the state does not change for a period of 10 seconds, a Sensor will revert to a “no motion” state. (Contact UVSS for custom settings faster or slower than 10 seconds.)  b. Choosing twice per second will display and log the greatest amount of detail. All activity from every sensor will be recorded twice per second.  7.  Archive events days. Enter the age of events to archive by entering the number of days old from 1 to 31.  Archived events will be saved in a comma delimited file in c:\uvss directory. 8. Auto Archive interval. Select weekly, bi-weekly or monthly.  9. Select Apply to save settings.  After Sensors and Contacts are Configured (see below) you can return to Configure System at any time to view System Summary or Contact Summary.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 21Set Map Scale   Follow steps for Configure System above to connect to the site plan image file.   Select Monitor Screen.  The selected site plan should appear. Click Config/ Set Map scale in the upper tool bar. Enter a distance (ft) for configuring the map. The distance will show on the map image. Move the distance boxes until the distance matches a known measurement. Save.   Configure Sensor using Monitor Screen  Configure sensors for Range and Mass Threshold by selecting Config / Edit Sensor from the top toolbar. Double-click on the sensor you wish to change. Enter new values. Save.  For a more complete list of configuration settings, see the Configure Sensor section.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 22Configure Contacts  1. To configure the output performance of an individual Sensor, select Configure Contacts. 2. Select the device from the Select Dry contact Device pull down list.     3. Enter the sensor number to the Sensor column (ex 5,10,etc). Entries can either be a single sensor (ex:5) or in multiples (ex: 5,10,20). Tab or Enter to activate columns to set configurations. The contact switch chosen is independent of the sensor number. “ALL” can be used when any sensor can activate the same switch.  4. The number of sensors is dependent on the device settings. Add Device allows you to add a new switching device. Enter the location, access code and number of settings. Save.  5. Edit Device is used to change the access code or number of contacts.  6. Use the drop down boxes to configure each sensor depending on the input requirements of integrated alarm or CCTV panels when alarm notification is desired. Each condition is described on the next page of this manual. Example: Choose the opposite condition for “No Motion” when the Sensor is not detecting motion. In this example, the contact will “close” on intrusion detection and remain “open” when no motion is detected.  7. After configuring individual contacts, select Save changes. You will be asked to confirm the current Sensor configuration. If correct select Yes. 8. Repeat this process for as many sensors and contact closures as required.  9. To delete a device, select the device from the Select Dry contact Device pull down list. The Delete Device button is activated. Select and confirm.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 23Contact Closure Detail  • Motion – motion detected by an UltraSensor that meets the alarm threshold criteria defined on the Configuration page will be indicated by a red icon on the Monitor Screen and recorded in the Log. It will also cause the chosen contact to open or close, as selected, sending a signal to associated systems (CCTV, access control, etc.).  • Warning – is an indication of motion within the full extent of the UltraSensor detection range but greater than the alarm range parameters set on the Configuration page. Icon will become yellow. Setting “warning” to open or close will cause the chosen contact to activate associated systems. Recommended setting is ignore except in high security applications where recognition of any motion within range of the UltraSensor is desirable.  • No-Motion – an absence of motion within the full range of an UltraSensor will be indicated by a green icon on the Monitor Screen. No-motion will cause the chosen contact to open or close, as selected, sending a signal to an associated systems (CCTV, access control, etc.). If Motion is set to open, set “No-motion” to closed.  If Motion is set to closed, set “No-motion” to open. • Noise – the occurrence of RF interference with performance of an UltraSensor will be indicated by a blue icon on the Monitor Screen and recorded in Log. Setting noise to either open or closed will cause the activation of an associated system to create another level of awareness.  • Heartbeat – UltraSensor communicates with the Server twice per second and upon initial power up “heartbeat” is displayed on the User Interface and recorded in the System log. Succeeding “heartbeats” are not logged nor displayed. If a Sensor loses communication with the System (cut cable, power loss, Sensor malfunction, etc.), a visual indication will be generated on the Monitor Screen (orange icon with “X”) and recorded in the Log. Setting “heartbeat” to open or close will cause an activation of a contact upon initial power up only. Heartbeat is the opposite of “power.”  Recommended setting for heartbeat is ignore. • Power – an absence of individual Sensor power will generate a visual indication on the Monitor screen (orange icon with “X”) and be recorded in the Log. Setting “power” to close or open will cause an activation of the contact upon power loss only.   The choice of open or closed will be based upon the required input status of the associated system. Individual contacts may be programmed for multiple non-conflicting functions. For example when integrating with a CCTV system, Contact #1 can be set to open on No-motion, close on Motion, and close on Warning to activate a camera to record any motion from a given UltraSensor. Operational conditions like Power and Heartbeat would normally not call for camera activation and should be linked to other contacts to create operator or monitor awareness.    Monitor Screen
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 241. Once Sensors have been placed on the facility graphic and configured, Users may monitor Sensor activity by viewing the Monitor Screen. Select Monitor Screen from the menu. A graphic representation of the facility with Sensors in approximate locations will be displayed.  2. The circle surrounding each Sensor displays the approximate total detection area of each Sensor. Colored circle icons indicate as follows: a. Green – No motion b. Yellow – Motion detected outside of alarm threshold c. Red – Motion detected inside of alarm threshold (contact activation) d. Orange – Loss of sensor communications (trouble) e. Grey – Sensor configured as disabled.  f. Blue – Excessive environmental “noise”    3. As shown above, the Monitor Screen also shows a mini-log of current Sensor activity.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 25View Log File  1. Viewing Log activity is available to Administrator level users only.  2. To view Log Activity, click on View Log File from Menu Screen.    3. All administrative activity will be displayed on a white background, warning events on a yellow background, alarm events on a red background and heartbeats on a green background.      4. Alarms may be Archived or Dismissed. Only Administrative Level users may Archive or Dismiss events. a. Select Archive Events to clear and move the dated events in the log, as specified in the configure system screen, into a comma delimited file located within the c:\uvss directory.  b. Select Dismiss Events to dismiss/delete all events by selecting Dismiss All Events or individually by checking the event(s) then selecting Dismiss Checked. You will be asked to confirm when dismissing events.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 26 Configure Alarm Mass Threshold (Sensitivity)  In order to adjust your system to detect people and ignore small animals such as birds,  a number must be determined for each sensor Alarm Mass Threshold.   The actual detection of a moving person will determine the setting for each individual sensor.   Use the following steps:  1. On the Configure System screen, set the Alarm Logging Option to “twice per second”.  2. Set the Alarm Mass Threshold setting at 10 for each sensor. 3.  Have a person walk to and over each sensor at a normal walking speed. Note the time that each sensor is passed. Do this for every sensor.  4. Go to View Log File. Note the lowest Mass reading for each sensor. This number will probably be different for each sensor. This is normal as each sensor might be buried under different materials or at different depths.  5. Subtract 10 from the lowest Mass reading for each sensor and enter this number as the Alarm Mass Threshold number for that sensor.  6. Once all the sensors are configured, return to the Configure System screen and set the Alarm Logging Option to “once per incident”.  Note: This is a good starting point to having each sensor detecting people and ignoring false alarms from smaller objects. The Mass Threshold can be further optimized as  the user’s familiarity with the system is increased.   Logout  1. From any screen, a User may logout by selecting Logout from the menu at the left of the screen.  2. The User will be asked to confirm logout. If correct, select Yes.  Software Updates  Periodically, UVSS will add new features or enhancements to the software. To take advantage of these changes, please contact tech support at: techsupport@ultravisionsecurity.com  3/11/09 Version 10.9 Server software released. See Release 10.9 Notes page 41 for more information.
   UltraVision Security, Inc. • Salem, New Hampshire  03079 USA • Tel 866.374.9732  • 603.685.0303  • Fax 603.898.1840 www.UltraVisionSecurity.com • info@UltravisionSecurity.com Rev 031109 27 Sensor Specifications  Both the CMD1 and the CMD2 sensors have similar specifications. The primary difference is the CMD2 is water resistant for outdoor use and is larger in size.  1. Power ‘on-off’ operable through a standard computer network. 2. Motion detection of human size objects or larger will trigger the alarm, smaller objects are eliminated through the “mass threshold” setting. 3. Detection range is user selectable from 5 to 25 foot (1.5 -8m) radius when buried in earth six to twelve inches (15-30 cm). 4. Transmitter Frequency Range: 200 to 600 MHz. 5. POE power and communications. Standard IP compatibility. 6. Power, user supplied 240/120 VAC to the network hub, POE is 48 VDC from computer to concentrator box, then 12 VDC to sensors. 7. Alarm amplitude sensitivity is factory set and user adjustable, little or no drift.  8. Automatic self-adjusting for changing background noise. 9. Laptop on the security network controls the operating parameters (alarm range and sensitivity level) and monitors operation and communication established, through continuous polling. 10. Dry switch output that closes on alarm condition can connect to cameras and other alarm devices. 11. Operating Temperature Range -10 degrees to 55 degrees C. 12. The CMD2 is watertight to a depth of one meter. 13. All sensor software is upgradeable through the Internet.
     Rev 031109  28 Integrating the CMD-Server 24 with your network  The CMD-Server 24 communicates to clients (laptops and PCs) via a Netgear FVS318 router. Specifically, using a web browser like Microsoft’s Internet Explorer and entering an IP address will allow you to become a client of the CMD-Server. The IP address of the CMD-Server is preset to a value of 10.10.0.11 at manufacturing time. However, this can be changed to another value if the preset address is not compatible with your existing network. If there is no existing network, the user must purchase a router and configure it to be compatible with the CMD-Server’s preset IP address, or configure the CMD-Server to be compatible with the router if a different set of IP addresses is desired.  Changing the CMD-Server IP address  Warning: This procedure should only be attempted by qualified network administrators. Changing parameters other than those describe in this document can result in a non-functioning product that must be reset by UltraVision’s Support personnel.  For this procedure you will need a router configured with a subnet of 10.10.0.0 and a subnet mask of 255.255.255.0 as well as a computer with either a compatible static IP address or a dynamic one if the router and the computer are setup to use DHCP (note that some systems ship with a separate Netgear model FVS114 router preconfigured to these settings). Next, connect both the CMD-Server and computer to the LAN side of the router. On the computer, run Internet Explorer and login to the CMD-Server router (Netgear model FVS318) by typing https://10.10.0.11:8080 . It is very important that you include the reference to port 8080 in your command-line, otherwise you will access the CMD-Server UltraSensor Security System instead of the Netgear router located inside the CMD-Server. If you entered the command correctly, you should see a small dialog box prompting you for a username and password as shown below:   The default username is admin and the password is generic11..  . You should now have access to the full web interface of the Netgear router.
     Rev 031109  29 Change the IP address, select Basic Settings from the left menu bar and enter the parameters in the main window that will make the CMD-Server compatible with your network:     Accessing the CMD-Server over a WAN  The CMD-Server can be accessed from anywhere in the world if the LAN to which it is connected is configured to allow in-coming traffic. There are generally two ways that this can be done. The easiest (but less secure) approach is to setup the router that communicates with your ISP (Internet Service Provider) to use Port Forwarding of all HTTPS services so they are sent to the IP address of the CMD-Server. A much more secure, but significantly more difficult approach is to use VPN tunneling. The instructions for implementing a VPN tunnel go beyond the scope of this document. For detailed information please visit your router manufacturer’s website and consult with your network administrator on the best approach for your needs.
     Rev 031109  30 Integrating the CMD-Server 8 with your network  The CMD Server 8 communicates via a Netgear FVS114 router. Using a web browser like Microsoft’s Internet Explorer and entering an IP address will allow you to view and control the server 8 as though you were physically at its keyboard. The IP address of the Server-8 is preset to a value of 10.10.0.10 at manufacturing time. However, this can be changed to another value if the preset address is not compatible with your existing network. If there is no existing network, the user must purchase a router and configure it to be compatible with the CMD Server-8’s preset IP address, or configure the CMD Server-8 to be compatible with the router if a different set of IP addresses is desired.  Changing the CMD Server-8 IP address  Warning: Changing parameters other than those described in this document can result in a non-functioning product.  On the CMD Server-8 laptop, open a web browser and type http://10.10.101.253. You should receive a login window like the one shown on the next page. Enter the username “admin” and password “password” (typed without quotation marks). Select “Basic Settings” on the left column if they are not already displayed in the center column. Scroll down to “use static IP address” and enter your network address parameters. (The Server-8 is preconfigured with an IP=10.10.0.10, Mask=255.255.255.0, GW=10.10.0.1 and DNS Primary=10.10.0.1) When finished, select Logout at the bottom of the left column. Connect the CMD Server-8 Network connector to your network. At another computer on this same network, open a web browser and type the UVSS default https://10.10.0.10 or the new IP that was previously entered. The Server-8 display should now be visible.  Accessing the CMD-Server over a WAN  The CMD-Server can be accessed from anywhere in the world if the LAN to which it is connected is configured to allow in-coming traffic. There are generally two ways that this can be done. The easiest (but less secure) approach is to setup the router that communicates with your ISP (Internet Service Provider) to use Port Forwarding of all HTTPS services so they are sent to the IP address of the CMD-Server. A much more secure, but significantly more difficult approach is to use VPN tunneling. The instructions for implementing a VPN tunnel go beyond the scope of this document. For detailed information please visit your router manufacturer’s website and consult with your network administrator on the best approach for your needs.
     Rev 031109  31
     Rev 031109  32  Remote Switch Device  The UltraVision Remote Switch Device application software supports the integration of remote dry contact switches, such as those manufactured by Measurement Computing, with the UltraVision Sensor Servers.   This allows users to control a wide array of hardware components, such as alert lights, audible alarms and security cameras, automatically when one or more UltraSensors detects a change in an area being monitored. Remote switches may be physically installed anywhere when connected to the company network or to the internet.  The UltraVision Remote Switch Device application can be executed on any Windows XP or Windows Vista PC and can control up to 48 switches using one or more contact devices manufactured by Measurement Computing (USB-ERB08 or USB-ERB24).  During normal operation, the application resides in the Windows system tray, automatically changing the switch settings as directed by the associated UltraVision Sensor Server.  Users can use the application GUI to monitor current switch settings, manually change switch settings and/or change server settings.  Installation  The UltraVision Remote Switch Device application can be installed using the following procedure: z Insert the UltraVision Remote Switch Device Installation CDROM into the CD tray on a Windows XP or Windows Vista PC z In most Windows PC operating environments the installation program will be automatically executed when the CDROM is loaded by the operating system.  If not, use the Windows File Explorer to open the device folder associated with the CDROM and double-click on  setup.exe file to start the installation program. z When the installation program is started, it will display a banner page indicating the version of the software being installed, press Next to work through the installation steps
     Rev 031109  33 z When prompted to enter the Configuration Details, enter the Server IP or Hostname associated with the UltraVision Sensor Server running on your network.  The Location and Access Code fields must correspond to those assigned to one of the Remote Contact Devices configured on the UltraVision Sensor Server using the Configure Contacts page. (See the UltraVision Sensor Server Administration Guide for more details.)  NOTE: It is safe to leave any or all of the fields empty during installation if you don't know the information (or no Remote Contact Devices have been configured on the server yet).  In that case, the Remote Switch Device application will simply not connect to any server until you enter the configuration information. z Press Next to complete the installation steps Running the Application  When initialized, the UltraVision Remote Switch Device application searches for all Measurement Computing switch devices connected to the PC via USB cables.  Due to the nature of the driver provided by Measurement Computing, the USB devices must be connected to the PC before the Remote Switch Device is executed.  If not, you'll need to exit the Remote Switch Device and restart it before it will find the Measurement Computing devices. The Measurement Computing USB-ERB08 and USB-ERB24 devices are easily connected to any Windows PC using a standard USB cable.  Once connected and powered up, the Windows O/S will automatically recognize and load any drivers required for that device.   In most Windows environments you will hear an audible alert from Windows when it has successfully loaded the USB device driver.  After the USB device has been successfully connected to the PC, select the following entry from
     Rev 031109  34the Windows Start Menu: Programs => UltraVision => UltraVision Remote Switch Device Upon successful execution, the UltraVision icon will be visible in the Windows system tray (the set of icons in the lower-right corner of the Windows Desktop): Whenever that icon is present, the Remote Switch Device is active and, if configured properly, will be automatically updating any Measurement Computing switches as directed by the UltraVision Sensor Server. At any time while the application is running, you can double-click on the icon in the system tray to open the application's Graphical User Interface (GUI).  The GUI allows you to: z Monitor and/or alter the current state of each switch z Modify the server configuration information z Monitor the application log and/or flash the LED on the Measurement Computing device When the application GUI is launched, it will initially display a list of all the switches currently being controlled, as seen here:  The Contacts tab not only shows the current state of each switch being controlled, it also allows you to manually change the state of each switch simply by toggling the associated checkbox.  This feature can be used to test switch settings or as part of a standard operating procedure that requires the operator to set or reset a switch for various reasons.
     Rev 031109  35 If all of the entries are disabled, then either no Measurement Computing device was found connected to the PC or the server configuration information is incomplete or incorrect.  In that case, select the Diagnostics tab to view the log and determine the cause of the problem.  Removing the Application  The UltraVision Remote Switch Device application is easily removed from the system using the following procedure: z If the application is currently running, double-click on the icon in the system tray to open the application GUI and press Exit Application to stop the application z Select Settings => Control Panel from the Windows Start Menu z Double-click Add or Remove Programs in the Control Panel window z Select Change or Remove Programs from the left menu and select UltraVision Remote Switch Device from the list of currently installed programs z Press Remove to remove the application
     Rev 031109  36 Dry contact switch specifications for Server-8
     Rev 031109  37 Dry contact switch specifications for Server-24
     Rev 031109  38  Problem Solving  If application’s monitor display shows sensors as an orange dot with an “X” AND Digi Discovery can detect the sensors;   Stop and restart the II service by going to the Windows Start Menu (Press Window Pane Key on keyboard) then selecting stop IIS. A command window will flash on the display.  You may see Internet Explorer error messages but ignore them; they will be continuous until this next step.  In the Windows Start Menu select start IIS. A command window will flash on the display. Answer OK to any Internet Explorer error messages that you received. Icons should return to appropriate colors but sensors may take up to 3 minutes to start responding.   If the database becomes corrupt, you can reinstall the program. Please note that all records, map and sensor configurations will be deleted. A new install should only be done when all other attempts to repair the database fail.   Update application by going to the Windows Start Menu (Press Window Pane Key on keyboard) then selecting update script. A command window will be displayed. Select option 3 for full installation. When it finishes scrolling, select option 2 to exit.
     Rev 031109  39 Install MS .NET framework and Java   Use these instructions to install MS .NET framework and Java on a Server 24 running UltraSensor 10.7 or higher.  To use an UltraSensor Server laptop on the web you need to configure it for DHCP so it will find an IP address and then change it back to a specific IP to reuse as the UltraSensor Server.  You get to the IP address window by going to: Start Settings Network Connections Local Area Connection Properties Highlight Internet Protocol (TCP/IP) Select Properties  These should be the current IP addresses to use for setting it back as a Server, IP Address  10.10.101.254 Subnet Mask 255.255.255.0 Default Gateway 10.10.101.253 DNS Server 10.10.101.253 Alternate DNS is blank  Select “Obtain IP address automatically” for both top and bottom of window (This will blank out the numbers above) “OK” all the way out Now you should be able to get on the network.  Here’s the link to install Microsoft .NET framework.  http://www.microsoft.com/downloads/details.aspx?familyid=333325fd-ae52-4e35-b531-508d977d32a6&displaylang=en  On that page, select “.NET Framework 3.5 full package”   (Most others listed will only change the bootstrap) It’s OK to chose RUN Accept all questions, it will place the files where it wants.  To install Java: Go to www.java.com  Select FREE JAVA DOWNLOAD
     Rev 031109  40 Allow a remote PC to fully communicate with a Server-8  This resolves 2 symptoms exhibited by the remote PC: 1) The site map area is all red 2) Remote switch bank will not work At the Server-8 PC: 1) Log out of the UltraSensor application 2) Stop the service by going to START and select ‘Stop UltraSensor’ 3) Open an Internet Explorer window (it will fail to find the local site) 4) In the URL area type   www.routerlogin.net 5) Log in using “admin” for user name, “password”  for password, without quotation marks then select OK 6) On the left column, select “Services”  To correct the map issue; A) Select “Add custom service” B) In the NAME field type “MapViewer” without quotation marks C) If not already displayed use the dropdown menu to select TCP for TYPE (not TCP/UDP) D) Type “2201” without quotation marks in both the START AND FINISH PORT fields E) Select APPLY (Will display all services in a table)  To correct the switch bank issue (optional, you don’t need to use a remote switch bank) A) Select “Add custom service” B) In the NAME field type “SwitchBank” without quotation marks C) If not already displayed use the dropdown menu to select TCP for TYPE (not TCP/UDP) D) Type “2200” without quotation marks in both the START AND FINISH PORT fields E) Select Apply (Will display all services in a table)  7) Select “Rules” on the left column 8) Under “Inbound Services”, select “ADD” 9) Scroll through “Service” menu, select MapViewer 10) For Action use dropdown menu to select “Allow Always” 11) For LAN type in 10.10.101.254 12) For WAN use dropdown menu to select ANY 13) Start and Finish IPs should be all zeros 14) For LOG use dropdown menu to select NEVER 15) Select APPLY 16) Should see new entry in table (HTTPS will also be there and must remain)  If you have a remote switch bank, repeat steps 8 through 16 but select “SwitchBank” instead of “MapViewer” in step 9.  Scroll down left column to select Logout and Yes to close window. Go to START to Start UltraSensor.
     Rev 031109  41 Release 10.9 Notes   Version 10.9  Upgrade Process  Execute the Upgrade.cmd script contained in the top-level directory of the distribution package to upgrade any version 10.4 or greater server to the current version.  Distribution packages are cumulative, so there is no need to upgrade to each version.  Simply run the upgrade script for the latest version to upgrade any previous version.  When the Upgrade.cmd script is executed, it will allow you to:  • upgrade just the server functionality (retaining current database data and user    configuration),  • upgrade the server and database (retaining user configuration), or upgrade everything (losing all data and setting the server to factory default settings).   Summary  The following significant changes were made to the UltraVision Sensor Server:  • Added the UltraSensor Switch API  • Added the UltraSensor Monitor API  • Enhanced Audit Log archiving and pruning mechanisms  • Enhanced the incident processing logic in the server to better filter false motion alarms.  Each of these changes are discussed in more detail below.  Graphical User Interface (GUI) Changes  The following specific changes were made to the web-based Guard and Administrator Console used to monitor and control the UltraVision Sensor Server:  • Added the Configure Monitors page to the Administrator Console to allow administrators to configure remote monitor accounts.  Remote monitor accounts allow client applications to monitor server activity using the new UltraSensor Monitor API (see below for details). This page also allows administrators to see a list of all active monitor connections.   • Added the Online Event Retention and Archive Log Retention properties to the Configure System page to allow administrators to specify how long event records should be retained in the database and how long archive event logs should be retained in the file system, respectively. This gives administrators better control over how database and file system resources are used on the server.   • Removed the Auto Archive Interval property from the Configure System page which was made obsolete by the archive process changes described below.
     Rev 031109  42• Added the Archived Logs button to the View Audit Log page to allow administrators to view the list of Audit Log archive files currently stored on the server.  The new Audit Log Archive page also allows administrators to export a CSV file containing all archived audit records for a given day.   • Modified the View Audit Log and View Event Log displays to limit the number of rows displayed in the GUI table and exported to a CSV file.  This prevents users from accidentally trying to display more rows than the database, web server and browser are capable of handling.   Server Changes   The following specific changes were made to the server functionality and configuration mechanisms:  • Fixed a bug that was preventing switch actions based on the POWER event from triggering properly.   • Added support for the UltraSensor Switch API that allows client applications to receive switch state changes as defined on the Configure Switches administrator page.  Client applications using this API must specify a valid Switch ID (e.g., location) and Access Code as defined on the Configure Switches page in order to start receiving state changes as events are processed by the server.   • Added support for the UltraSensor Monitor API that allows client applications to monitor server activity, including server property changes, target data and event data. Client applications using this API must specify a valid Monitor ID and Access Code as defined on the new Configure Monitors page in order to access the server.  • Fixed a problem with the maintenance task that prevented it from properly archiving and pruning the Audit/Event log on some systems.  Event records are now automatically deleted from the database when they are older than the number of days specified by the Online Event Retention property on the Configure System page. The Online Event Retention property determines how far back in time Operators and Administrators can view Event Log or Audit Log records using the View Event Log and View Audit Log pages.   • The Audit Log is now archived to individual CSV files on a daily basis in the c:\uvss\archive directory on the server.  The daily files make it easier for administrators to find past events for a given time period.  Furthermore, the format of the archive files is now the same as that used when exporting the Audit Log from the GUI, making it easier to post-process the CSV files. Archive files are automatically removed from the file system when they are older than the number of days specified by the Archive Log Retention property on the Configure System page.
     Rev 031109  43• Added support for the LogViewMaxRows and LogExportMaxRows configuration properties in the c:\uvss\blogic.ini file to control the maximum number of events that can be displayed in the GUI event table and exported to CSV files, respectively.  The properties can be optionally specified as part of the [GUI] category, as in the following example:  [GUI] LogViewMaxRows=1000 LogExportMaxRows=5000  • Added support for the MOTION_COUNT_FILTER and MOTION_RANGE_FILTER configuration properties in the c:\uvss\blogic.ini file to fine-tune the algorithm used to filter out false alarms.  a.)  If MOTION_COUNT_FILTER is an integer greater than 1 (default value is 2), then the server will wait for a consecutive number of motion events before generating an alarm. This prevents alarms from being generated for spurious motion events.   b.)  If MOTION_RANGE_FILTER is a decimal value greater than zero (default value    is 0), then the difference between the first motion event range and last motion event range (as determined by the MOTION_COUNT_FILTER) must be greater than or equal to the MOTION_RANGE_FILTER value (specified in feet)  in order for an alarm to be generated. This prevents alarms from being generated unless two or more consecutive motion events occur with a “decreasing” range (i.e., target moving towards the sensor).  - For example, suppose MOTION_COUNT_FILTER is specified as 2 and the MOTION_RANGE_FILTER is specified as 0.5 feet.    - If the first motion event occurred at a range of 10 feet and the second consecutive motion event occurred at a range of 9 feet, then an alarm would be generated.                - If the second consecutive motion event occurred at a range of 9.6 feet, then an  alarm would not be generated at that time.  However, if the 3rd consecutive motion event occurred at a range of 9.2 feet, then the alarm would be generated.  • Added support for the INCIDENT_DEBUG configuration variable which allows technical support staff to log incident processing information for a given sensor.  For example, if the INCIDENT_DEBUG variable is set to “3”, then only the incident processing information for Sensor 3 will be output to the server log.  The amount of debug information generated could be quite large, so this configuration variable should be used only when actively trouble-shooting event filtering problems.   • All server logs have been moved from the c:\uvss directory to the c:\uvss\logs directory to better organize the server runtime directory.   • Created a new daily maintenance log in c:\uvss\logs to assist with trouble-shooting maintenance issues.
     Rev 031109  44    Thank you for purchasing our product.                                      Technical Support  Email: techsupport@ultravisionsecurity.com                                        Contact information   UltraVision Security Systems, Inc., 16 Northwestern Drive, Salem NH 03079 USA www.UltraVisionSecurity.com info@UltraVisionSecurity.com Tel: 866-374-9732       603-685-0303   Fax: 603-898-1840