OWNER’S MANUAL

UNIDEN Model UH013
UHF CB Radio

UNIDEN Model UH013 UHF CB Radio

Contents
Introduction
Features
Preventive Maintenance
Troubleshooting

Controls / Connectors
Indicators
Included with your UH013
Mounting Options
Operation
Setting the Squelch
Monitor
Selecting a Channel
Transmitting
Using Repeater Channels
Operating the UH013 in Duplex Mode
Scanning
Open Scan (OS) Mode
Group Scan (GS) Mode
Programming Scan Channels
Busy Channel Lockout
VOX Operation (optional VOX headset required)
Programming the Instant Priority Channel
Recalling the Instant Channel
CTCSS (Continuous Tone Coded Squelch System)
Wide Band Scanning
Searching
Scanning Stored Frequencies
Programming Scan Frequencies

Selective Calling (Optional Selcall PCB Required)
Frequency & CTCSS Tone Lists
Warranty

1

2
2
2
2
3
4
5
6
8
8
8
9
9
9
10
10
10
11
11
12
12
12
12
13
13
14
14
14
15
16
17

UNIDEN Model UH013 UHF CB Radio

Introduction
The Uniden UH013 is designed to provide you with years of trouble free service. Its rugged components and
materials are capable of withstanding harsh environments.
We are certain that you will enjoy your UH013. Please read this Operating Manual carefully to ensure you gain
the optimum performance of the unit.

Features
Detachable Display Unit

Open Scan

Transmit & Receive FM 40CH (UHF-CB, TX Power 5w)

Busy Channel Lock-out

2 Levels Preset Squelch

38 Built-in CTCSS codes

Wide Band Scanner (400MHz - 512MHz) = WS Function

Volume Control with Power On/Off Switch

Band Search Function (4 Bands separately)
LCD Display with Backlight

VOX (Voice Activated Function) optional VOX headset
required

Signal Strength Meter

9 Step VOX Mic sensitivity adjustment

RF Power Indicator

Memory backup if power fails

One touch Instant Channel recalling

Optional Tone Squelch Unit Function

Duplex Capability (from CH01 - CH08 per channel)

Tone Squelch Function (5/6 Tone) optional

Group Scan and Priority Channel Watch

Tone Calling Function (5/6 Tone) optional
Tone Squelch Scan optional

Preventive Maintenance: The following system checks should be made every six to twelve months:
Check the Standing Wave Ratio (SWR).
Inspect the tightness of all electrical connections.
Inspect the antenna coaxial cable for wear or breaks on the shielding.
Inspect the tightness of all screws and other mounting hardware.

Troubleshooting: Should the unit malfunction or perform poorly, follow these procedures:
If the transceiver is completely inoperative: Check the power cord and fuse.
If there is trouble with receiving: Check the VOLUME control setting. Be sure the SQUELCH is adjusted
properly. Possibly the radio is over-squelched.
If there is trouble with transmitting: Check that the transmission line (coaxial cable) is securely connected
to the ANTENNA connector. Check that the antenna is fully extended for proper operation. Check that all
transmission line (coaxial cable) connections are secure and free of corrosion.

NOTE

Blackening may occur on the Liquid Crystal Display if the UH013 has been subjected to extreme high
temperature (above 60°C) . This is not a fault. Normal LCD operation resumes when the temperature
stabilizes back to standard operating conditions (0 to 55°C).

2

UNIDEN Model UH013 UHF CB Radio

Controls / Connectors
1

2

5

3

6

4

Rotary
Channel
Selector

VOX
CTCSS

TX WS CAL TSQ DUP
MON SCN GS BCL INS

VOL

SLT
SLT SRC HLD SQT M
MHz

S/RF

SLCT

SRCH

SCAN

MEM

INST

SQT

STORE

TSQ

OS/GS

DUP

SET/SKIP

CTCSS

Front
7

8

9

10

12

11

15

Rear
EXT.SP.

13
DC 13.8V

14

UHF ANT.

Controls and Connectors
Ref.

Item

Page

Ref.

Item

Page

1

Liquid Crystal Display (LCD)

4

9

SCAN - Open or Group Scan

10, 11

2

Rotary Channel Selector

9

10

MEM - Memory Button

11

3

On/Off Volume

8

11

12

4

Push to Talk (PTT) Button

9

INST - Instant Set, Instant Channel
Recall and Instant Channel
Programming

5

Tone Call

15

12

SQT - Squelch Mode

13

6

Monitor Button

8

13

External Speaker Jack

-

7

SLCT - Select Button

12, 13

14

Power Input (13.8V DC)

-

8

SRCH - Search Button

14

15

UHF Antenna Connection

-

3

UNIDEN Model UH013 UHF CB Radio

Indicators

16

23 22 21 20 19
17

18
24

VOX
CTCSS

TX WS CAL TSQ DUP
MON SCN GS BCL INS

25
26

SLT

SRC HLD SQT M
MHz

S/RF

29 31
27

28

30

32

33

Page

Ref.

34

35

Indicators
Item

Page

16 VOX - Voice Operated Microphone 12

26 SCN - Scan

10

17 CTCSS - Continuous Tone Coded
Squelch System

13

27 SLT - Select

9

28 SRC - Search

14

18 INS - Instant Channel

12

29 HLD - Hold

14

30 BCL - Busy Channel Lockout

12

Ref.

Item

19 DUP - Duplex

9 - 10

20 TSQ - Tone Squelch (Optional)

9

31 SQT - Squelch Tight

21 CAL - Tone Call (Optional)

15

22 WS - Wide Band Scanner

13

32 M
33

23 TX - Transmit
24 GS - Group Scan
25 MON - Monitor

9

34
11

- Memory
- Channel Number
- CTCSS Code

35 S/RF - RF Signal Strength

8

4

8
14
-

UNIDEN Model UH013 UHF CB Radio

Included with your UH013

OWNER’

S MANU

AL

013
Model UH
UNIDENF CB Radio
UH

UH013 Owners Manual

Display Mount Bracket

Microphone

Transceiver

Microphone Hanger, Screws
and Washers

Mounting Bracket, Knobs,
Washer Stars and Screws

FIX
AF MP
A
ST RE
HE

UH013

Lim
Pty
lia ion

VOL

SLCT
STORE

SRCH
TSQ

SCAN
OS/GS

MEM
DUP

INST
SET/SKIP

d
ite

a is y
str Div wa 6
Au e igh 21
en ic H 2
id Serv ces SW
Un ttn: Prin le N
A 45 da ALIA
3 o ck TR
R US
A

SQT
CTCSS

Display Unit

DC Power Cord with Fuse

Display Rear Bracket

Extension Cable

5

Consumer Support Card

UNIDEN Model UH013 UHF CB Radio

Mounting Options
The radio can be mounted complete - or - with the Display Unit remote of the Transceiver.

Mounting the complete radio (Transceiver with Display Unit)
a)
b)

b
c)

a

c

Plug in display cable from the
Display Unit to the transceiver.
Hinge the Display Unit into the
transceiver as shown in the
diagram, then snap closed.
Should you wish, at a later stage,
to position the Display Unit remote
from the Transceiver, release the
Display Unit by pushing up the slide
on the side.

b

Remote mounting of the Transceiver Unit

If the Display Unit is not already separate
of the Transceiver then remove it as
detailed in c) above.
Fix the Transceiver Mounting Bracket in
an appropriate location (screws and
washers supplied). Then fix the
Transceiver in the bracket using the Knob
bolts supplied d).
The bracket can be fixed on the top or
under the transceiver. An arced slot e)
allows you to mount the transceiver at an
angle.

e
d

6

UNIDEN Model UH013 UHF CB Radio

Mounting Options
Remote mounting of the Display Unit

a

Fixing the Display Rear Bracket
To mount the Display Unit it needs to
be fitted with a Display Rear Bracket
(included in package).
a)

Position the Display Rear Bracket
so that one end fits over the two
studs at the end of the Display
Unit.
Push it into place until the fixing
screw hole is aligned with its
threaded counterpart.
Secure the Display Rear Bracket
with the screw provided.

b)
c)

b

c

Top fix

d

Optional mounting positions
The Display Unit can be mounted from the top, back or bottom.
d) Fix the Display Mount Bracket in place (above, at the
rear or at the bottom) by screwing through the slots in
the bracket.
e) Fix the Display Unit to the bracket with the
thumb screws provided.
f) Connect the Extension Cable between the Display
Unit and the Transceiver.

Back fix

Bottom fix

e
UH013
VOL

f

SLCT
STORE

SRCH
TSQ

MEM
DUP

SCAN
OS/GS

7

INST
SET/SKIP

SQT
CTCSS

UNIDEN Model UH013 UHF CB Radio

Operation
Setting the Squelch
Turn the Unit ON by rotating the
volume control clockwise.
The UH013 has 2 Levels Preset
Squelch. It requires no adjustment.
However, if you are in a very high
noise area it may break through.
Press SQT to select the tight squelch
mode. The SQT icon appears.

NOTE

CAL TSQ DUP

Rotary
Channel
Selector

MON SCN GS BCL INS
SLT

VOL

SRC HLD SQT M
S/RF

MHz

SLCT

SRCH

SCAN

MEM

INST

SQT

STORE

TSQ

OS/GS

DUP

SET/SKIP

CTCSS

Selecting tight squelch mode may prevent the
reception of weak signals.

Strong Signals
Medium Signals
Weak Signals
Noise

Think of the squelch control as a
gate. If the squelch is fully closed
no signal can get through.

Strong Signals

Strong Signals

Medium Signals

Medium Signals

Weak Signals

Weak Signals

Noise

Noise

If the squelch is fully open ‘Monitor
Mode’ it allows all signals to get
through - weak, medium and strong
signals and noise.

By setting the squelch to ‘threshold’,
it blocks out all weak signals and
noise and allows only the required
medium and stronger signals to pass
through.
Strong noise may still break through.
Press SQT to select the ‘Tight
Squelch’ mode. The SQT icon
appears.

MONI

Monitor
Press the MONI button on the microphone to open the squelch and receive all
weak signals. Press and hold the MONI button for 2 seconds to hold the squelch
open (Monitor Mode). Press MONI again momentarily to cancel.

8

UNIDEN Model UH013 UHF CB Radio

Operation
Selecting a Channel
Turn the Rotary Channel Selector to select the
desired channel.

Rotary
Channel
Selector

CAL TSQ DUP
MON SCN GS BCL INS
SLT

SRC HLD SQT M
S/RF

MHz

SLCT

SRCH

SCAN

MEM

INST

SQT

STORE

TSQ

OS/GS

DUP

SET/SKIP

CTCSS

PTT

Transmitting
Select the desired channel. Press the Microphone’s PTT button and speak normally
into the microphone. Hold it approx. 7cm from your mouth. Release the PTT button
to end the transmission and listen for a reply.

Using Repeater Channels
UHF CB Repeaters are used to retransmit or relay your signal. Repeaters will extend the range of your radio and
overcome the shielding effect caused by solid obstructions. In normal Simplex operation, your radio transmits on
one particular frequency and receives on that same frequency. If there is a barrier that partially blocks your
transmitted signal, the probability of another radio receiving the signal is very slim. Hills, tall buildings, metallic
structures, ... etc. tend to act as a screen between radios.
Repeater Station

Normal Simplex Operation
Transmitting on CH 31

CH 31

CH 01

No Signal
being Received

Operation with the aid of
Repeater Station (Duplex)

Standard Operation without
the aid of a Repeater Station

The Signal coming from your radio is received by the Repeater Station and then retransmitted at the same time
on another channel. This operation is called "Duplexing".
For example,
CH01 on Duplex Mode will Receive on CH 01 but Transmit on CH31
CH02 on Duplex Mode will Receive on CH 02 but Transmit on CH32 etc ....
If you transmit on CH01 Duplex mode, you are actually transmitting on CH31, the repeater station down-converts
your signal and retransmits on CH01.

9

UNIDEN Model UH013 UHF CB Radio

Operation
Operating the UH013 in Duplex Mode
For this example we are adopting CH01 as the channel being used in your area for repeater use.
Press and hold DUP for 2 seconds to switch
Duplex ON. The DUP icon appears.
If Duplex is not required - press DUP and hold for
2 seconds again to switch Duplex off.
Only channels 01 - 08 are available for Duplex

NOTE

CAL TSQ DUP
MON SCN GS BCL INS
SLT

VOL

SRC HLD SQT M
S/RF

MHz

SRCH

SCAN

MEM

INST

SQT

TSQ

OS/GS

DUP

SET/SKIP

CTCSS

Check with your local Retailer for
information on available Repeaters.

Scanning
The UH013 has a scanning feature that allows you to search for active channels automatically.
Furthermore, the UH013 is designed to have two types of scanning; Open Scanning (OS) and Group Scanning
(GS), to give you flexibility and allow you to use the radio more effectively.
Press SCAN and Scanning starts. The SCN
icon appears.
CAL TSQ DUP
Press SCAN again to stop scanning.
MON SCN GS BCL INS
SLT

SRC HLD SQT M
S/RF

MHz

SRCH

SCAN

MEM

INST

SQT

TSQ

OS/GS

DUP

SET/SKIP

CTCSS

Open Scan (OS) Mode
Allows continuous scanning of channels stored in the Open Scan memory. If an active channel is found, scanning
will stop on that channel.
CAL TSQ DUP
VOX
CTCSS
This example shows CH40 active.
MON SCN GS BCL INS
SLT SRC HLD SQT M
If the received signal ceases, the unit will wait 3 seconds for the signal
S/RF
to return, otherwise scanning resumes.
To skip the active channel, press MEM momentarily. Scanning resumes. To deactivate SCAN, press SCAN
or the PTT button on the microphone.
MHz

NOTE

If SCAN is deactivated while on an
active channel, the UH013 will stay on
that active channel. If no channels are
active, the UH013 will reinstate the
starting channel.

NOTE

10

OS Mode is indicated by the absence of
the GS icon.

UNIDEN Model UH013 UHF CB Radio

Operation
Group Scan (GS) Mode
Allows you to monitor a Priority (Instant) Channel while scanning (Instant Priority channel see p.12)
To use GS Mode Scanning, press and hold SCAN for 2 seconds.
VOX
CAL TSQ DUP
GS icon appears on the display.
CTCSS
MON SCN GS BCL INS
SLT

SRC HLD SQT M

S/RF
GS Scanning checks the Instant Priority Channel for activity regularly.
If the Priority Channel becomes active the radio will stay on that channel for as long as the signal is present. If
the received signal ceases, Priority Scanning continues after 3 seconds.
If scanning stops on a channel which is not a Priority Channel, UH013 will continue monitoring the Priority Channel
for activity while listening to the active one.
To deactivate SCAN, press the SCAN button
or the PTT button.
CAL TSQ DUP
Rotary
MON SCN GS BCL INS
Press and hold SCAN for 2 seconds to turn
Channel
SLT SRC HLD SQT M
off Group Scan Mode.
Selector
MHz

S/RF

MHz

SLCT

SRCH

SCAN

MEM

INST

SQT

STORE

TSQ

OS/GS

DUP

SET/SKIP

CTCSS

NOTE

If SCAN is deactivated while it is tuned to an active channel, the UH013 will stay on that active
channel. If none of the channels are active, the UH013 will reinstate the Starting Channel.
If SCAN is deactivated while it is turned to the Instant Priority Channel, the UH013 will remain on
the Instant Priority Channel.

NOTE

If GS Scanning is initiated when there are no channels programmed in GS memory, an error tone
will be heard and scanning will not start (see Programming Scan Channels - below).

Programming Scan Channels
Select which Scanning Mode you wish to use
- OS or GS.
Select the channel you want to store.
Press MEM to store. M icon appears and
a short tone beep is heard.
To remove the channel from Memory, press
MEM
once more. The M icon disappears.

NOTE

CAL TSQ DUP

Rotary
Channel
Selector

MON SCN GS BCL INS
SLT

SRC HLD SQT M
S/RF

MHz

SLCT

SRCH

SCAN

MEM

INST

SQT

STORE

TSQ

OS/GS

DUP

SET/SKIP

CTCSS

OS is indicated by the absence of
the GS icon.

11

UNIDEN Model UH013 UHF CB Radio

Operation
Busy Channel Lockout
If the channel is already in use, you can prevent
the UH013 from transmitting . This is particularly
important when using CTCSS.
Press SLCT 2 times. Turn the Rotary Channel
Selector to display
. Press and hold
SLCT for 2 seconds to store the new setting.

NOTE

If a button is not pressed within 10
seconds the UH013 will
automatically exit Select Mode.

Rotary
Channel
Selector

CAL TSQ DUP
MON SCN GS BCL INS
SLT

SRC HLD SQT M

SLCT

SRCH

SCAN

MEM

INST

SQT

STORE

TSQ

OS/GS

DUP

SET/SKIP

CTCSS

VOX Operation (optional VOX headset required)
Press SLCT 3 times. Turn the Rotary
Channel Selector to select the desired VOX

sensitivity (1 - 9).

CAL TSQ DUP

Press and hold
for 2 seconds to store
the new setting. Connect the VOX headset.
SLCT

NOTE

If a button is not pressed within 10
seconds the UH013 will
automatically exit Select Mode.

Rotary
Channel
Selector

VOX

MON SCN GS BCL INS
SLT

SRC HLD SQT M
S/RF

SLCT

SRCH

SCAN

MEM

INST

SQT

STORE

TSQ

OS/GS

DUP

SET/SKIP

CTCSS

Programming the Instant Priority Channel
Turn the Rotary Channel Selector to select the
Priority Channel you prefer.
Press and hold INST for 2 seconds to store
the new setting. INS icon appears.

CAL TSQ DUP

Rotary
Channel
Selector

MON SCN GS BCL INS
SLT

SRC HLD SQT M
S/RF

MHz

SLCT

SRCH

SCAN

MEM

INST

SQT

STORE

TSQ

OS/GS

DUP

SET/SKIP

CTCSS

Recalling the Instant Channel
Momentarily press the

INST

key at any time to return to the Instant Channel.

12

UNIDEN Model UH013 UHF CB Radio

Operation
C T C S S (Continuous Tone Coded Squelch System)
Turn the Rotary Channel Selector to the desired
channel to use CTCSS. Press and hold
SQT for 2 seconds. CTCSS icon flashes.
Turn the Rotary Channel Selector to select the
desired CTCSS code 01 - 38. Press SQT
once to store the new setting.

NOTE

Rotary
Channel
Selector

CTCSS

MHz

SLCT

SRCH

SCAN

MEM

INST

SQT

STORE

TSQ

OS/GS

DUP

SET/SKIP

CTCSS

Channels 05 and 35 are Emergency Channels
and channel 11 is a Calling Channel.
CTCSS cannot be selected on these channels.

NOTE

If a button is not pressed within 10
seconds the UH013 will automatically
exit Select Mode.

Wide Band Scanning

The UH013 can also scan a wider band of frequencies (Step: 12.5 KHz).
Band
A
B
C
D

Frequencies
400 MHz - 420 MHz
420 MHz - 450 MHz
450 MHz - 470 MHz
470 MHz - 512 MHz

1. Press SLCT once.
2. Turn the Channel Selector to select
.
3. Press and hold SLCT for 2 seconds to
store the new setting.
Searching of band A will immediately begin.

NOTE

Rotary
Channel
Selector

Transmission is not possible on wide band
frequencies.

WS CAL TSQ DUP
MON SCN GS BCL INS
SLT

SRC HLD SQT M

SLCT

SRCH

SCAN

MEM

INST

SQT

STORE

TSQ

OS/GS

DUP

SET/SKIP

CTCSS

13

UNIDEN Model UH013 UHF CB Radio

Operation
Searching
Searching checks every frequency within the Band. If an active channel is located the UH013 will stop on that
channel until 2 seconds after the transmission ends, then continue.
Search Hold
1. To stop the search, press SRCH at any time. HLD is displayed.
2. To continue, press SRCH again.
Skip
If a particular frequency continues to interrupt searching, you can set your radio to skip the frequency by pressing
the INST button during search hold (you may skip up to 10 frequencies). To cancel Skip, press INST again
while search holding at the desired frequency. To cancel all Skipped frequencies, press and hold
INST for 2 seconds during search hold.
Changing the Search Band
While searching press and hold SRCH for 2 seconds. The UH013 will move to the next band.

Rotary
Channel
Selector

TX WS CAL TSQ DUP
MON SCN GS BCL INS
VOL

SLT
SLT SRC HLD SQT M
S/RF
MHz

SLCT

SRCH

SCAN

MEM

INST

SQT

STORE

TSQ

OS/GS

DUP

SET/SKIP

CTCSS

Scanning Stored Frequencies

You may store up to 40 frequencies from any band into memory and then only scan those frequencies
for activity.
1. Select Wide Band Scanning (see page 13).
2. Press SCAN .
3. To stop the Scan, press SCAN at any time. HLD is displayed.
4. To continue, press SCAN again.

Programming Scan Frequencies
1. Select wide band scanning (see page 13).
2. Press SCAN and turn the Channel selector to choose a memory location (41 - 80).
3. Press SRCH to approach the desired frequency.
4. Turn the Channel Selector to stop searching and fine tune to the exact frequency.
5. Press MEM to store the selected frequency.
NOTE

Repeat procedure as necessary to programme the other memory locations.

Deleting stored frequencies
1. Select the desired memory location.
2. Press and hold SCAN for 2 seconds to delete the selected frequency.

14

UNIDEN Model UH013 UHF CB Radio

Selective Calling (Optional Selcall PCB Required)
Outline
Selective Calling (SELCALL) is a special Sequential Tone Squelch System that allows the user to receive/transmit
calls selectively from/to an individual or group, on a shared busy channel.
The UH013 has an Optional Selective Calling system.
Exceptional features, like Receiver Quieting, Tone Squelch Scanning, Tone and Group Calling make the UH013
superior to any transceivers in its class.

Receiver Quieting (Tone Squelch)
When activated, it automatically mutes the receiver audio circuit of the radio.
It will stay in this ‘Quiet’ mode as long as the SELCALL tone code (SELCALL ID) required to open the muting
circuit is not received.

Call Alarm
When a received code matches to your SELCALL ID, an alarm (CA Alert) will be emitted informing you that a
caller is on the channel.

Tone Squelch Scanning
Scans only tone squelched Channels.

Tone Calling
Allows you to selectively call another radio.

Group Calling Capability
Transmits and Responds to Group Calls.

15

UNIDEN Model UH013 UHF CB Radio

Frequency & CTCSS Tone Lists
FM UHF - CB Frequency List - Australia & New Zealand
Simplex Mode
Transmit / Receive
Frequency (MHz)

Duplex Mode
Transmit
Frequency (MHz)

Simplex Mode
Transmit / Receive
CH No. Frequency (MHz)

CH No.
476.425
477.175 CH31
21
01
476.925
476.450
477.200 CH32
22
02
476.950
476.475
477.225 CH33
03
23
476.975
477.250 CH34
476.500
04
24
477.000
476.525
477.275 CH35
05
25
477.025
477.300 CH36
476.550
06
26
477.050
477.325 CH37
476.575
07
27
477.075
477.350 CH38
476.600
08
28
477.100
476.625
09
29
477.125
476.650
10
30
477.150
476.675
11
31
477.175
476.700
12
32
477.200
476.725
13
33
477.225
476.750
14
34
477.250
476.775
15
35
477.275
476.800
16
36
477.300
476.825
17
37
477.325
476.850
18
38
477.350
476.875
19
39
477.375
476.900
20
40
477.400
NOTE: Channel 05 and 35 are Emergency Channels and channel 11 is a Calling Channel.

CTCSS TONE List
Tone
No.

Tone
Frequency (Hz)

Tone
No.

Tone
Frequency (Hz)

00 (’oF’)
01
02
03
04
05
06
07
08
09
10
11
12

OFF
13
103.5
67.0
14
107.2
71.9
15
110.9
74.4
16
114.8
77.0
17
118.8
79.7
18
123.0
82.5
19
127.3
85.4
20
131.8
88.5
21
136.5
91.5
22
141.3
94.8
146.2
23
97.4
151.4
24
100.0
156.7
25
NOTE: Channel 05 11 and 35 are not CTCSS programmable.

16

Tone
No.

Tone
Frequency (Hz)

26
27
28
29
30
31
32
33
34
35
36
37
38

162.2
167.9
173.8
179.9
186.2
192.8
203.5
210.7
218.1
225.7
233.6
241.8
250.3

UNIDEN Model UH013 UHF CB Radio

Warranty
ONE YEAR LIMITED WARRANTY
IMPORTANT: Evidence of the original purchase is required for warranty service.
WARRANTOR: Uniden New Zealand Limited. Uniden Australia Pty Ltd. ACN 001 865 498
ELEMENTS OF WARRANTY: Uniden warrants to the original retail owner for the duration of this
warranty its UH013 (hereinafter referred to as the Product), to be free from defects in materials
and craftsmanship with only the limitations or exclusions set out below.
WARRANTY DURATION: This warranty to the original retail owner only is only valid in the original
country of purchase and shall be of no further effect 12 months after the date of original retail
sale. This warranty will be deemed invalid if the Product is: (A) Damaged or not maintained as
reasonable and necessary, (B) Modified, altered or used as part of any conversion kits,
subassemblies, or any configurations not sold by Uniden, (C) Improperly installed, (D) Repaired
by someone other than an authorised Uniden Repair Agent for a defect or malfunction covered
by this warranty, (E) Used in conjunction with any equipment or parts or as a part of a system
not manufactured by Uniden. (F) Only available in the original country of sale.
PARTS COVERED: This warranty covers for one (1) year, the UH013 tranceiver only. All
accessories (Mounting bracket, Microphone etc.) are covered for 90 days only.
STATEMENT OF REMEDY: In the event that the Product does not conform to this warranty at
any time while this warranty is in effect, the warrantor, at its discretion, will repair the defect or
replace the Product and return it to you without charge for parts and service. THIS WARRANTY
DOES NOT COVER OR PROVIDE FOR THE REIMBURSEMENT OR PAYMENT OF INCIDENTAL
OR CONSEQUENTIAL DAMAGES. THIS GUARANTEE IS IN ADDITION TO AND DOES NOT
IN ANY WAY AFFECT YOUR RIGHTS UNDER THE CONSUMER GUARANTEE ACT.
PROCEDURE FOR OBTAINING PERFORMANCE OF WARRANTY: in the event that the Product
does not conform to this warranty, the Product should be shipped or delivered, freight prepaid,
with evidence of original purchase (e.g. a copy of the sales docket) to the warrantor at:
UNIDEN AUSTRALIA PTY LIMITED
SERVICE DIVISION
345 Princes Highway,
Rockdale,
NSW 2216,
AUSTRALIA
Ph: (02) 9599-3100
Fax: (02) 9599-3278
Toll Free: 1300 36 895

UNIDEN NEW ZEALAND LIMITED
SERVICE DIVISION
150 Harris Road,
East Tamaki,
Auckland,
NEW ZEALAND
Ph: (09) 273 8383
Fax: 274 0009
Toll Free: 0800 486 4336

www.uniden.com.au

www.uniden.co.nz

17

C 2002

Uniden Australia Pty Limited / Uniden New Zealand Limited

Printed in the Philippines
PPC: UTZZ01887ZZ



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 19
EXIF Metadata provided by EXIF.tools

Navigation menu