Unimo Technology UDM-240ZH ISM Band Near Field Communication User Manual UDM 240ZH Service Manual 140613
Unimo Technology Co., Ltd. ISM Band Near Field Communication UDM 240ZH Service Manual 140613
User Manual
UDM-240ZBH,ZH Service Manual Maintenance Manual ※ BEFORE USING THIS ♣ Please read this manual in detail before using the device. (Please read and understand the manual before using this equpment) ♣ Features can be subject to change or modify without any prior notice for its improvement of performance (better performance) ♣ Copyright of this manual belongs to UNIMO Technology Co., Ltd., in a whole or in part authorized copy or modify are prohibited. ♣ Pictures on this manual may differ from the actual products. ♣ Please contact our local agency or Unimo A/S division directly if you have any questions. UDM-240ZH/ZBH Maintenance Manual Safety Precautions This content is for user’s safety and property. Please read it and fully understand. (Details affect to its performance and appearance) Please use recommended voltage for input power supply voltage. Battery, adapter, external ear-phones are designed to Unimo models. Using nonUnimo goods can cause damage or malfunction to the product. Please use communication purpose only. Please do not disassemble or modify the product. Damage or malfunction caused by those, won’t be repaired free of charge. ※ Avoid severe impact to the product. ※ Please keep avoid being exposed to direct sunlight or high temperatures and a lot of humidity UDM-240ZH/ZBH Maintenance Manual Details affect to the operation of radios or other equipments. Communication range can be shortened near the products using 2.4GHz due to interference of electric wave. (Microwave, Wi-Fi, Computer, other equipment using 2.4GHz,… etc.) Turn off the radio on airplane. Please follow the instructions or rules when you use it. Please check whether can use or not before using the radio the due to electronic effect. Do not use the radios near electronic equipments such as Wi-Fi or computers. Radios may does not work properly due to strong interference ※ Electromagnetic waves in a variety of electrical and electronic equipment occurs. The influence of electromagnetic interference is generated. Distance calls can also be shortened remarkably. UDM-240ZH/ZBH Maintenance Manual Safety Requirement Please read the following information about safe and effective use of the product. Keep your distance at least 1 inch(2.5cm) from your body when you use the radios. Make sure the regulations regarding the use of radio while driving, please do not use the radios as much as possible while you drive. Use additional accessories, such as earphones, for your safety. Do not listen at very high volume. Your hearing may be affected. For use in hazardous areas, only explosion-proof device must be used. Within the hazardous areas, do not remove, exchange or charge/discharge the battery. If an electrical spark pops up in hazardous areas, it can cause severe burns or death. Turn it off around the workplaces, causing an explosion of electromagnetic behavior of the product. UDM-240ZH/ZBH Maintenance Manual 1 FEATURES UDM-240ZH is designed to have light and durable structure and it provides a powerful sound. It is the first product using 2.4GHz band developed in Korea and provides a clear digital sound. UDM-240ZH is designed to provide adequate service for industrial products, public safety users. It also provides clear digital radio communication between the UDM-240ZV and can be operated with the existing VHF, UHF, TETRA vehicle and base station and can communicate remotely if it’s interfaced with UDM-240ZV. Clear 3FND Display 16 channels (#11~#26) Perfect security. (AES 128bit) 1,150mAh built-in LI-ION battery pack Group Call SCAN Group Scan UDM-240ZH : 0:11~26, 1:11~15, 2:16~20, 3:21~26 UDM-240ZBH : 0:11~25, 1:11~15, 2:16~20, 3:21~25 Volume Control (up to 8 Level) Ear-Phone Function Cradle type of Charger RX/TX while charging Good design due to a built-in antenna Designation of group ID up to 64,000 1 to N communication (per channel/ group ID) IP67 (Waterproofed) UDM-240ZH/ZBH Maintenance Manual 2 COMPONENTS 2-1 Basic Components 2-2 Optional Components *** Components can be changed according to the request. UDM-240ZH/ZBH Maintenance Manual 3 DESCRIPTION OF CONTROLS & INDICATORS Detail operating instructions can be found in the next page. 3-1 Key and Button Power On/Off button Press the “power” button for more than 2 seconds then, the UDM is turned ON. Press the “power” + “menu” button for more than 2 seconds then, the UDM is turned OFF. Depending on the application, the power button can be used as a PTT button or INT button. UP, Down button Up/Down buttons are used for changing channels. The number of channels are 16(11Ch ~ 26CH) and it can be displayed C11~C26 or H11~H26. Main-PTT If you press this button, the UDM-240ZH will be transmission mode and if you release UDM-240ZH/ZBH Maintenance Manual the button, the UDM-240ZH will be turned to standby mode. Sub PTT This function can be programmed to the power button on the side of the UDM. It is used for transmission on a pre-programmed channel. Menu button It can be used to select and set user configurable features. Earphone jack The Earphone Jack on the top of the UDM will be used for interface with external earphone. The UDM-240ZH can be programmed by its PC program and programming cable. 3-2 Display Status LED The users can be recognized the current status by LED indicator on the top of the UDM. The status indication will be as followings. FND Display Displays menu function through 3FND type LCD Ptt : TX status using the C channel Int : TX status using the H channel Ud1 : Program version(1st) Ud2 : Program version(2nd) UDM-240ZH/ZBH Maintenance Manual OFF : Power OFF UDM-240ZH/ZBH 10 Maintenance Manual 4 HOW TO USE 4-1 Power ON/OFF 4-2 HOW TO CHARGE The built-in Li-ion battery is safe and reliable to guarantee high-performance. Batteries MUST be fully charged before use. Battery charging time Low battery voltage will shorten the talk range and will make the performance of radio worse. When Battery Charging is needed; - After using the battery 4 ~5 hours the performance is seemed to be reduced. UDM-240ZH/ZBH 11 Maintenance Manual - Check the battery indicator using the “menu” button, and FND displayed as below. E– F(100%), E– 4(75%), E– 3(50%), E– 2(25%), E– E(Need to charge) HOW TO CHARGE ☞ Battery charger used with UDM-240ZH must be supplied by UNIMO Technology Co., Ltd Other manufacturer’s can cause unexpected damage of the battery and terminal. CAUTIONS UDM-240ZH/ZBH 12 Maintenance Manual 5 DESCRIPTION OF FUNCTION 5-1 POWER On/Off 5-2 TRANSMIT While pressing the “PTT” or “power” button for transmitting, the red LED will be on and through the setup channel, you can communicate. For the better sound quality, it is recommended to take 5~10cm away from your body. According to the program versions FND can be displayed as follows. ”or ” “ 5-3 ”or ” ”or” ” RECEIVE User can adjust the volume level (1~8 steps) by using Up/Down button while receiving. According to the program versions FND can be displayed as follows. ”or ” “ 5-4 ”or ” ”or” ” CHANGE THE CHANNEL Enter into the menu mode by pressing menu button and press Up/Down button to change the channels. Whenever the channel is changed, a “beep” sound will be heard. According to the option program source the channel menu will be changed. UDM-240ZBH: use Up/Down button in the standby mode). Main channel (PTT Button) : C11 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 C23 C24 C25 UDM-240ZH/ZBH 13 Fixed channel (power button) : C26(fixed for transmit) Maintenance Manual UDM-240ZH: use Up/Down button in the menu mode (C channel ,H channel selectable) 5-5 Main channel (PTT Button) Spare channel (Power Button) SCAN In the standby mode, enter into the menu mode then enable or disable SACN function. Scan( ) Scan Group ( )select press the PTT button to save : ALL (11~25CH), SCAN group in the UDM-240ZBH: : 11~15CH, : 15~20CH, : 21~25CH SCAN channels in the UDM-240ZH: 11CH ~ 26CH 5-6 FND DISPLAY According to operational status FND shows following displays; Main Channel: 16CH Sub channel: 16CH Volume display: 8 levels UDM-240ZH/ZBH 14 Maintenance Manual 5-7 INSTALLATION FOR PC PROGRAM AND SETUP UDM-240ZH/ZBH 15 Maintenance Manual UDM-240ZH/ZBH 16 Maintenance Manual UDM-240ZH/ZBH 17 Maintenance Manual UDM-240ZH/ZBH 18 Maintenance Manual UDM-240ZH/ZBH 19 Maintenance Manual UDM-240ZH/ZBH 20 Maintenance Manual UDM-240ZH/ZBH 21 Maintenance Manual 5-8 Functional differences between the version of the program Please note that between the old and new version of the program, the UDM-240ZV[ZH] are not compatible each other. UDM-240ZH/ZBH 22 Maintenance Manual 6 DESCRIPTION FOR CIRCUIT UDM-240ZH/ZBH 23 Maintenance Manual 6-1 Wireless communication protocol chips (ISM 2.4Ghz) 6-2 Digital voice signaling circuit UDM-240ZH/ZBH 24 Maintenance Manual 6-3 Function control circuit 6-4 TX power/RX sensitivity AMP Circuit UDM-240ZH/ZBH 25 Maintenance Manual 6-5 Power supply circuit 6-6 FND display Circuit UDM-240ZH/ZBH 26 Maintenance Manual 6-7 FND display Circuit 6-8 Battery charger circuit UDM-240ZH/ZBH 27 Maintenance Manual 6-9 Audio AmP 6-10 Ear Phone circuit UDM-240ZH/ZBH 28 Maintenance Manual 7 PCB MAP 7-1 TOP UDM-240ZH/ZBH 29 Maintenance Manual 7-2 BOTTOM UDM-240ZH/ZBH 30 Maintenance Manual 7-3 Circuit Diagram UDM-240ZH/ZBH 31 Maintenance Manual UDM-240ZH/ZBH 32 Maintenance Manual FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is con-nected. • Consult the dealer or an experienced radio/TV technician for help. Caution Modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC Compliance Information : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation IMPORTANT NOTE: FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. UDM-240ZH/ZBH 33
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author :EXIF Metadata provided by EXIF.toolsCreate Date : 2014:11:25 13:26:35+09:00 Modify Date : 2015:01:23 12:25:08+09:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Title : Microsoft Word - UDM-240ZH Service Manual_140613 Creator : Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2015:01:23 12:25:08+09:00 Producer : Acrobat Distiller 9.5.5 (Windows) Document ID : uuid:4cb00de3-4db8-41e7-af46-663c90259d70 Instance ID : uuid:d81d7ea9-53ac-45d3-aae2-9f68c7684e69 Page Count : 33