USER INSTRUCTIONS Durco Mark 3 sealed metallic pumps Mark 3 Standard, In-Line, Lo-Flo, Recessed Impeller, Unitized Self-Priming and Sealmatic pumps Installation Operation Maintenance PCN=71569102 08-06 (E) (incorporating P-10-502-E) These instructions must be read prior to installing, operating, using and maintaining this equipment. MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 CONTENTS Page Page CONTENTS ............................................................ 2 6 MAINTENANCE................................................. 39 6.1 Maintenance schedule................................. 40 6.2 Spare parts.................................................. 40 6.3 Recommended spares and consumable items....................................... 41 6.4 Tools required.............................................. 41 6.5 Fastener torques ......................................... 41 6.6 Setting impeller clearance and impeller replacement................................................ 42 6.7 Disassembly................................................ 44 6.8 Examination of parts.................................... 47 6.9 Assembly of pump and seal ......................... 50 1 INTRODUCTION AND SAFETY .......................... 3 1.1 General......................................................... 3 1.2 CE marking and approvals ............................ 3 1.3 Disclaimer..................................................... 3 1.4 Copyright ...................................................... 3 1.5 Duty conditions ............................................. 3 1.6 Safety ........................................................... 4 1.7 Name plate and safety labels ........................ 7 1.8 Noise level .................................................... 8 2 TRANSPORT AND STORAGE............................ 9 2.1 Consignment receipt and unpacking.............. 9 2.2 Handling ....................................................... 9 2.3 Lifting............................................................ 9 2.4 Storage ....................................................... 10 2.5 Recycling and end of product life..................11 3 DESCRIPTION.................................................. 11 3.1 Configurations..............................................11 3.2 Nomenclature ..............................................11 3.3 Design of major parts .................................. 12 3.4 Performance and operation limits ................ 12 4 INSTALLATION................................................. 18 4.1 Location ...................................................... 18 4.2 Part assemblies .......................................... 18 4.3 Foundation.................................................. 18 4.4 Grouting...................................................... 20 4.5 Initial alignment ........................................... 21 4.6 Piping ......................................................... 22 4.7 Electrical connections ................................. 31 4.8 Final shaft alignment check ......................... 32 4.9 Protection systems...................................... 32 5 COMMISSIONING, STARTUP, OPERATION AND SHUTDOWN............................................ 33 5.1 Pre-commissioning procedure ..................... 33 5.2 Pump lubricants .......................................... 33 5.3 Impeller clearance....................................... 36 5.4 Direction of rotation ..................................... 36 5.5 Guarding..................................................... 36 5.6 Priming and auxiliary supplies ..................... 37 5.7 Starting the pump........................................ 38 5.8 Running or operation................................... 38 5.9 Stopping and shutdown ............................... 39 5.10 Hydraulic, mechanical and electrical duty .. 39 Page 2 of 68 7 FAULTS; CAUSES AND REMEDIES ................. 57 8 PARTS LIST AND DRAWINGS.......................... 59 8.1 Standard Mark 3 pump, Group 1.................. 59 8.2 Standard Mark 3 pump, Group 2 and Group 3 ................................... 60 8.3 Mark 3 Sealmatic pump, Group 2 ................ 61 8.4 Mark 3 Lo-Flo, Group 2................................ 61 8.5 Mark 3 Unitized Self Priming pump, Group 2 ....................................................... 62 8.6 Mark 3 Recessed Impeller pump, Group 2 ... 62 8.7 Mark 3 In-Line pump, Group 1 ..................... 63 8.8 Mark 3 In-Line pump, Group 2 ..................... 64 8.9 Mark 3 C-Face Adapter, Group 1 and Group 2 ................................... 65 8.10 General arrangement drawing ................... 65 9 CERTIFICATION ............................................... 66 10 OTHER RELEVANT DOCUMENTATION AND MANUALS............................................... 66 10.1 Supplementary User Instructions ............... 66 10.2 Change notes ............................................ 66 10.3 Additional sources of information ............... 66 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 1 INTRODUCTION AND SAFETY 1.1 General These instructions must always be kept close to the product’s operating location or directly with the product. Flowserve products are designed, developed and manufactured with state-of-the-art technologies in modern facilities. The unit is produced with great care and commitment to continuous quality control, utilizing sophisticated quality techniques, and safety requirements. Flowserve is committed to continuous quality improvement and being at your service for any further information about the product in its installation and operation or about its support products, repair and diagnostic services. These instructions are intended to facilitate familiarization with the product and its permitted use. Operating the product in compliance with these instructions is important to help ensure reliability in service and avoid risks. The instructions may not take into account local regulations; ensure such regulations are observed by all, including those installing the product. Always coordinate repair activity with operations personnel, and follow all plant safety requirements and applicable safety and health laws/regulations. These instructions must be read prior to installing, operating, using and maintaining the equipment in any region worldwide. The equipment must not be put into service until all the conditions relating to safety noted in the instructions, have been met. 1.2 CE marking and approvals It is a legal requirement that machinery and equipment put into service within certain regions of the world shall conform with the applicable CE Marking Directives covering Machinery and, where applicable, Low Voltage Equipment, Electromagnetic Compatibility (EMC), Pressure Equipment Directive (PED) and Equipment for Potentially Explosive Atmospheres (ATEX). Where applicable, the Directives and any additional Approvals, cover important safety aspects relating to machinery and equipment and the satisfactory provision of technical documents and safety instructions. Where applicable this document incorporates information relevant to these Directives and Approvals. Page 3 of 68 To confirm the Approvals applying and if the product is CE marked, check the serial number plate markings and the Certification. (See section 9, Certification.) 1.3 Disclaimer Information in these User Instructions is believed to be reliable. In spite of all the efforts of Flowserve Pump Division to provide sound and all necessary information the content of this manual may appear insufficient and is not guaranteed by Flowserve as to its completeness or accuracy. Flowserve manufactures products to exacting International Quality Management System Standards as certified and audited by external Quality Assurance organizations. Genuine parts and accessories have been designed, tested and incorporated into the products to help ensure their continued product quality and performance in use. As Flowserve cannot test parts and accessories sourced from other vendors the incorrect incorporation of such parts and accessories may adversely affect the performance and safety features of the products. The failure to properly select, install or use authorized Flowserve parts and accessories is considered to be misuse. Damage or failure caused by misuse is not covered by the Flowserve warranty. In addition, any modification of Flowserve products or removal of original components may impair the safety of these products in their use. 1.4 Copyright All rights reserved. No part of these instructions may be reproduced, stored in a retrieval system or transmitted in any form or by any means without prior permission of Flowserve Pump Division. 1.5 Duty conditions This product has been selected to meet the specifications of your purchaser order. The acknowledgement of these conditions has been sent separately to the Purchaser. A copy should be kept with these instructions. The product must not be operated beyond the parameters specified for the application. If there is any doubt as to the suitability of the product for the application intended, contact Flowserve for advice, quoting the serial number. If the conditions of service on your purchase order are going to be changed (for example liquid pumped, temperature or duty) it is requested that the user seeks the written agreement of Flowserve before start up. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 1.6 Safety 1.6.1 Summary of safety markings These User Instructions contain specific safety markings where non-observance of an instruction would cause hazards. The specific safety markings are: This symbol indicates electrical safety instructions where non-compliance will involve a high risk to personal safety or the loss of life. This symbol indicates safety instructions where non-compliance would affect personal safety and could result in loss of life. This symbol indicates “hazardous and toxic fluid” safety instructions where non-compliance would affect personal safety and could result in loss of life. This symbol indicates safety instructions where non-compliance will involve some risk to safe operation and personal safety and would damage the equipment or property. NEVER DO MAINTENANCE WORK WHEN THE UNIT IS CONNECTED TO POWER (Lock out.) DRAIN THE PUMP AND ISOLATE PIPEWORK BEFORE DISMANTLING THE PUMP The appropriate safety precautions should be taken where the pumped liquids are hazardous. FLUOROELASTOMERS (When fitted.) When a pump has experienced temperatures over 250 ºC (482 ºF), partial decomposition of fluoroelastomers (example: Viton) will occur. In this condition these are extremely dangerous and skin contact must be avoided. HANDLING COMPONENTS Many precision parts have sharp corners and the wearing of appropriate safety gloves and equipment is required when handling these components. To lift heavy pieces above 25 kg (55 lb) use a crane appropriate for the mass and in accordance with current local regulations. This symbol indicates explosive atmosphere zone marking according to ATEX. It is used in safety instructions where non-compliance in the hazardous area would cause the risk of an explosion. NEVER OPERATE THE PUMP WITHOUT THE COUPLING GUARD AND ALL OTHER SAFETY DEVICES CORRECTLY INSTALLED This sign is not a safety symbol but indicates an important instruction in the assembly process. GUARDS MUST NOT BE REMOVED WHILE THE PUMP IS OPERATIONAL 1.6.2 Personnel qualification and training All personnel involved in the operation, installation, inspection and maintenance of the unit must be qualified to carry out the work involved. If the personnel in question do not already possess the necessary knowledge and skill, appropriate training and instruction must be provided. If required the operator may commission the manufacturer/supplier to provide applicable training. THERMAL SHOCK Rapid changes in the temperature of the liquid within the pump can cause thermal shock, which can result in damage or breakage of components and should be avoided. Always coordinate repair activity with operations and health and safety personnel, and follow all plant safety requirements and applicable safety and health laws and regulations. 1.6.3 Safety action This is a summary of conditions and actions to help prevent injury to personnel and damage to the environment and to equipment. For products used in potentially explosive atmospheres section 1.6.4 also applies. Page 4 of 68 NEVER APPLY HEAT TO REMOVE IMPELLER Trapped lubricant or vapor could cause an explosion. HOT (and cold) PARTS If hot or freezing components or auxiliary heating equipment can present a danger to operators and persons entering the immediate area, action must be taken to avoid accidental contact (such as shielding). If complete protection is not possible, the machine access must be limited to maintenance staff only with clear visual warnings and indicators to those entering the immediate area. Note: bearing housings must not be insulated and drive motors and bearings may be hot. If the temperature is greater than 68 °C (175 °F) or below 5 °C (20 °F) in a restricted zone, or exceeds local regulations, action as above shall be taken. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 HAZARDOUS LIQUIDS When the pump is handling hazardous liquids care must be taken to avoid exposure to the liquid by appropriate pump placement, limiting personnel access and by operator training. If the liquid is flammable and/or explosive, strict safety procedures must be applied. Gland packing must not be used when pumping hazardous liquids. PREVENT EXCESSIVE EXTERNAL PIPE LOAD Do not use pump as a support for piping. Do not mount expansion joints, unless allowed by Flowserve in writing, so that their force, due to internal pressure, acts on the pump flange. ENSURE CORRECT LUBRICATION (See section 5, Commissioning, startup, operation and shutdown.) NEVER EXCEED THE MAXIMUM DESIGN PRESSURE (MDP) AT THE TEMPERATURE SHOWN ON THE PUMP NAMEPLATE See section 3 for pressure versus temperature ratings based on the material of construction. NEVER OPERATE THE PUMP WITH THE DISCHARGE VALVE CLOSED (Unless otherwise instructed at a specific point in the User Instructions.) (See section 5, Commissioning start-up, operation and shutdown.) NEVER RUN THE PUMP DRY OR WITHOUT PROPER PRIME (Casing flooded) NEVER OPERATE THE PUMP WITH THE SUCTION VALVE CLOSED It should be fully opened when the pump is running. 1.6.4 Products used in potentially explosive atmospheres • • • • • Measures are required to: Avoid excess temperature Prevent build up of explosive mixtures Prevent the generation of sparks Prevent leakages Maintain the pump to avoid hazard The following instructions for pumps and pump units when installed in potentially explosive atmospheres must be followed to help ensure explosion protection. Both electrical and non-electrical equipment must meet the requirements of European Directive 94/9/EC. 1.6.4.1 Scope of compliance Use equipment only in the zone for which it is appropriate. Always check that the driver, drive coupling assembly, seal and pump equipment are suitably rated and/or certified for the classification of the specific atmosphere in which they are to be installed. Where Flowserve has supplied only the bare shaft pump, the Ex rating applies only to the pump. The party responsible for assembling the pump set shall select the coupling, driver, seal and any additional equipment, with the necessary CE Certificate/ Declaration of Conformity establishing it is suitable for the area in which it is to be installed. The output from a variable frequency drive (VFD) can cause additional heating affects in the motor. On pump installations controlled by a VFD, the ATEX Certification for the motor must state that it covers the situation where electrical supply is from the VFD. This particular requirement still applies even if the VFD is in a safe area. NEVER OPERATE THE PUMP AT ZERO FLOW OR FOR EXTENDED PERIODS BELOW THE MINIMUM CONTINUOUS FLOW THE PUMP SHAFT MUST TURN CLOCKWISE WHEN VIEWED FROM THE MOTOR END It is absolutely essential that the rotation of the motor be checked before installation of the coupling spacer and starting the pump. Incorrect rotation of the pump for even a short period can unscrew the impeller, which can cause significant damage. Page 5 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 1.6.4.2 Marking An example of ATEX equipment marking is shown below. The actual classification of the pump will be engraved on the nameplate. II 2 GD c IIC 135 ºC (T4) Equipment Group I = Mining II = Non-mining Category 2 or M2 = high level protection 3 = normal level of protection Gas and/or dust G = Gas D = Dust c = Constructional safety (in accordance with EN13463-5) Gas Group (Equipment Category 2 only) IIA – Propane (typical) IIB – Ethylene (typical) IIC – Hydrogen (typical) Maximum surface temperature (Temperature Class) (see section 1.6.4.3.) 1.6.4.3 Avoiding excessive surface temperatures ENSURE THE EQUIPMENT TEMPERATURE CLASS IS SUITABLE FOR THE HAZARD ZONE Pump liquid temperature Pumps have a temperature class as stated in the ATEX Ex rating on the nameplate. These are based on a maximum ambient temperature of 40 ºC (104 ºF); refer to Flowserve for higher ambient temperatures. The surface temperature on the pump is influenced by the temperature of the liquid handled. The maximum permissible liquid temperature depends on the temperature class and must not exceed the values in the table applicable below. The temperature rise at the seals and bearings and due to the minimum permitted flow rate is taken into account in the temperatures stated. Maximum permitted liquid temperature for pumps Temperature class to EN 13463-1 T6 T5 T4 T3 T2 T1 Page 6 of 68 Maximum surface temperature permitted 85 °C (185 °F) 100 °C (212 °F) 135 °C (275 °F) 200 °C (392 °F) 300 °C (572 °F) 450 °C (842 °F) Temperature limit of liquid handled (* depending on material and construction variant – check which is lower) Consult Flowserve Consult Flowserve 115 °C (239 °F) * 180 °C (356 °F) * 275 °C (527 °F) * 400 °C (752 °F) * Maximum permitted liquid temperature for pumps with self priming casing Temperature class to EN 13463-1 T6 T5 T4 T3 T2 T1 Maximum surface temperature permitted 85 °C (185 °F) 100 °C (212 °F) 135 °C (275 °F) 200 °C (392 °F) 300 °C (572 °F) 450 °C (842 °F) Temperature limit of liquid handled (* depending on material and construction variant - check which is lower) Consult Flowserve Consult Flowserve 110 °C (230 °F) * 175 °C (347 °F) * 270 °C (518 °F) * 350 °C (662 °F) * The responsibility for compliance with the specified maximum liquid temperature is with the plant operator. Temperature classification “Tx” is used when the liquid temperature varies and the pump could be installed in different hazardous atmospheres. In this case the user is responsible for ensuring that the pump surface temperature does not exceed that permitted in the particular hazardous atmosphere. Do not attempt to check the direction of rotation with the coupling element/pins fitted due to the risk of severe contact between rotating and stationary components. Where there is any risk of the pump being run against a closed valve generating high liquid and casing external surface temperature, it is recommended that users fit an external surface temperature protection device. Avoid mechanical, hydraulic or electrical overload by using motor overload trips, temperature monitor or a power monitor and perform routine vibration monitoring. In dirty or dusty environments, regular checks must be made and dirt removed from areas around close clearances, bearing housings and motors. Additional requirements for self-priming casing pumps Where the system operation does not ensure control of priming, as defined in the User Instructions, and the maximum permitted surface temperature of the T Class could be exceeded, it is recommended that user install an external surface temperature protection device. 1.6.4.4 Preventing the build up of explosive mixtures ENSURE PUMP IS PROPERLY FILLED AND VENTED AND DOES NOT RUN DRY Ensure that the pump and relevant suction and discharge piping is totally filled with liquid at all times during the pumps operation so that an explosive atmosphere is prevented. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 In addition, it is essential to make sure that seal chambers, auxiliary shaft seal systems and any heating and cooling systems are properly filled. If the operation of the system can not avoid this condition it is recommended that you fit an appropriate dry run protection device (for example liquid detection or a power monitor). To avoid potential hazards from fugitive emissions of vapor or gas to atmosphere, the surrounding area must be well ventilated. 1.6.4.5 Preventing sparks To prevent a potential hazard from mechanical contact, the coupling guard must be non-sparking. To avoid the potential hazard from random induced current generating a spark, the earth contact on the baseplate must be used. 1.6.4.7 Maintenance of the centrifugal pump to avoid a hazard CORRECT MAINTENANCE IS REQUIRED TO AVOID POTENTIAL HAZARDS WHICH GIVE A RISK OF EXPLOSION The responsibility for compliance with maintenance instructions is with the plant operator. To avoid potential explosion hazards during maintenance, the tools, cleaning and painting materials used must not give rise to sparking or adversely affect the ambient conditions. Where there is a risk from such tools or materials, maintenance must be conducted in a safe area. It is recommended that a maintenance plan and schedule is adopted. (See section 6, Maintenance.) 1.7 Name plate and safety labels Avoid electrostatic charge: do not rub non-metallic surfaces with a dry cloth; ensure cloth is damp. 1.7.1 Nameplate For details of nameplate, see the Declaration of Conformity and section 3. The coupling must be selected to comply with 94/9/EC and correct alignment must be maintained. 1.7.2 Safety labels Additional requirements for pumps on nonmetallic baseplates When metallic components are fitted on a nonmetallic baseplate they must be individually earthed. 1.6.4.6 Preventing leakage Pumps with mechanical seal. The pump must only be used to handle liquids for which it has been approved to have the correct corrosion resistance. Avoid entrapment of liquid in the pump and associated piping due to closing of suction and discharge valves, which could cause dangerous excessive pressures to occur if there is heat input to the liquid. This can occur if the pump is stationary or running. Oil lubricated units only: Bursting of liquid containing parts due to freezing must be avoided by draining or protecting the pump and auxiliary systems. Where there is the potential hazard of a loss of a seal barrier fluid or external flush, the fluid must be monitored. DurcoShieldTM (Splash/Shaft Guard) only: If leakage of liquid to atmosphere can result in a hazard, the installation of a liquid detection device is recommended. Page 7 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 1.8 Noise level Attention must be given to the exposure of personnel to the noise, and local legislation will define when guidance to personnel on noise limitation is required, and when noise exposure reduction is mandatory. This is typically 80 to 85 dBA. The usual approach is to control the exposure time to the noise or to enclose the machine to reduce emitted sound. You may have already specified a limiting noise level when the equipment was ordered, however if no noise requirements were defined, then attention is drawn to the following table to give an indication of equipment noise level so that you can take the appropriate action in your plant. Pump noise level is dependent on a number of operational factors, flow rate, pipework design and acoustic characteristics of the building, and so the values given are subject to a 3 dBA tolerance and cannot be guaranteed. Motor size and speed Similarly the motor noise assumed in the “pump and motor” noise is that typically expected from standard and high efficiency motors when on load directly driving the pump. Note that a motor driven by an inverter may show an increased noise at some speeds. If a pump unit only has been purchased for fitting with your own driver then the “pump only” noise levels in the table should be combined with the level for the driver obtained from the supplier. Consult Flowserve or a noise specialist if assistance is required in combining the values. It is recommended that where exposure approaches the prescribed limit, then site noise measurements should be made. The values are in sound pressure level LpA at 1 m (3.3 ft) from the machine, for “free field conditions over a reflecting plane”. For estimating sound power level LWA (re 1pW) then add 14 dBA to the sound pressure value. Typical sound pressure level LpA 1 750 r/min 1 450 r/min Pump Pump and Pump Pump and only motor only motor <0.55(<0.75) 62 64 62 64 0.75 (1) 62 64 62 64 1.1 (1.5) 64 64 62 63 1.5 (2) 64 64 62 63 2.2 (3) 65 66 63 64 3 (4) 65 66 63 64 4 (5) 65 66 63 64 5.5 (7.5) 66 67 64 65 7.5 (10) 66 67 64 65 11(15) 70 71 68 69 15 (20) 70 71 68 69 18.5 (25) 71 71 69 71 22 (30) 71 71 69 71 30 (40) 73 73 71 73 37 (50) 73 73 71 73 45 (60) 76 76 74 76 55 (75) 76 76 74 76 75 (100) 77 77 75 77 90 (120) 77 78 75 78 110 (150) 79 80 77 80 150 (200) 79 80 77 80 200 (270) 85 87 83 85 300 (400) – 87 90 85 86 The noise level of machines in this range will most likely be of values which require noise exposure control, but typical values are inappropriate. Note: for 1 180 and 960 r/min reduce 1 450 r/min values by 2 dBA. For 880 and 720 r/min reduce 1 450 r/min values by 3 dBA. kW (hp) Page 8 of 68 3 550 r/min Pump Pump and only motor 72 72 72 72 74 74 74 74 75 76 75 76 75 76 76 77 76 77 80 81 80 81 81 81 81 81 83 83 83 83 86 86 86 86 87 87 87 88 89 90 89 90 2 900 r/min Pump Pump and only motor 64 65 64 66 66 67 66 71 68 72 70 73 71 73 72 75 72 75 76 78 76 78 77 78 77 79 79 81 79 81 82 84 82 84 83 85 83 85 85 87 85 87 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 2 TRANSPORT AND STORAGE 2.3.1.3 Bearing housing [3200] 2.1 Consignment receipt and unpacking Group 1: insert a sling between the upper and lower support ribs between the housing barrel and the casing attachment flange. Use a choker hitch when slinging. (Make sure there are no sharp edges on the bottom side of the ribs that could cut the sling.) Immediately after receipt of the equipment it must be checked against the delivery/shipping documents for its completeness and that there has been no damage in transportation. Any shortage and/or damage must be reported immediately to Flowserve Pump Division and must be received in writing within ten days of receipt of the equipment. Later claims cannot be accepted. Check any crate, boxes or wrappings for any accessories or spare parts that may be packed separately with the equipment or attached to side walls of the box or equipment. Each product has a unique serial number. Check that this number corresponds with that advised and always quote this number in correspondence as well as when ordering spare parts or further accessories. 2.2 Handling Boxes, crates, pallets or cartons may be unloaded using fork lift vehicles or slings dependent on their size and construction. Group 2 and 3: insert either a sling or hook through the lifting lug located on the top of the housing. 2.3.1.4 Power end Same as bearing housing. 2.3.1.5 Bare pump Horizontal pumps: sling around the pump discharge nozzle and around the outboard end of the bearing housing with separate slings. Choker hitches must be used at both attachment points and pulled tight. Make sure the completion of the choker hitch on the discharge nozzle is toward the coupling end of the pump shaft as shown in figure 2-1. The sling lengths should be adjusted to balance the load before attaching the lifting hook. 2.3 Lifting Pumps and motors often have integral lifting lugs or eye bolts. These are intended for use in only lifting the individual piece of equipment. Do not use eye bolts or cast-in lifting lugs to lift pump, motor and baseplate assemblies. To avoid distortion, the pump unit should be lifted as shown. Care must be taken to lift components or assemblies above the center of gravity to prevent the unit from flipping. This is especially true with In-Line pumps. 2.3.1 Lifting pump components 2.3.1.1 Casing [1100] Use a choker hitch pulled tight around the discharge nozzle. 2.3.1.2 Rear cover [1220] Insert an eye hook in the drilled and tapped hole at the top of the cover. Use either a sling or hook through the eye bolt. Page 9 of 68 Figure 2-1 In-Line pumps: lift with two slings through the pump adapter on opposite sides of the shaft. (Figure 2-2.) Bare pump with motor adapter (In-Line only): lift with two slings through the motor adapter shaft holes. This method is also used to lift the bare motor adapter. (Figure 2-2.) flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 2.4 Storage Store the pump in a clean, dry location away from vibration. Leave flange covers in place to keep dirt and other foreign material out of pump casing. Turn the pump shaft at regular intervals to prevent brinelling of the bearings and the seal faces, if fitted, from sticking. The pump may be stored as above for up to 6 months. Consult Flowserve for preservative actions when a longer storage period is needed. 2.4.1 Short term storage and packaging Normal packaging is designed to protect the pump and parts during shipment and for dry, indoor storage for up to six months or less. The following is an overview of our normal packaging: • All loose unmounted items are packaged in a water proof plastic bag and placed under the coupling guard • Inner surfaces of the bearing housing, shaft (area through bearing housing) and bearings are coated with Cortec VCI-329 rust inhibitor, or equal. Figure 2-2 2.3.2 Lifting pump, motor and baseplate assembly 2.3.2.1 Horizontal assemblies If the baseplate has lifting holes cut in the sides at the end (Type A Group 3, Type D and Type E bases) insert lifting S hooks at the four corners and use slings or chains to connect to the lifting eye. (Figure 2-1.) Do not use slings through the lifting holes. For other baseplates, sling around the pump discharge nozzle, and around the outboard end of the motor frame using choker hitches pulled tight. (Figure 2-1.) The sling should be positioned so the weight is not carried through the motor fan housing. Make sure the completion of the choker hitch on the discharge nozzle is toward the coupling end of the pump shaft as shown in figure 2-1. 2.3.2.2 In-Line assemblies If the pump is to be lifted as a complete assembly, the motor lifting lugs must be used to ensure that the assembly does not flip over. Check with motor supplier for lifting lug capacities. If there is any uncertainty, the motor should be removed prior to moving the pump. (Figure 2-2.) Page 10 of 68 • • • • • • Bearing housings are not filled with oil prior to shipment Regreasable bearings are packed with grease (EXXON POLYREX EM for horizontal pumps and EXXON UNIREX N3 for In-Line pumps) The internal surfaces of ferrous casings, covers, flange faces, and the impeller surface are sprayed with Cortec VCI-389, or equal Exposed shafts are taped with Polywrap Flange covers are secured to both the suction and discharge flanges In some cases with assemblies ordered with external piping, components may be disassembled for shipment The pump must be stored in a covered, dry location 2.4.2 Long term storage and packaging Long term storage is defined as more than six months, but less than 12 months. The procedure Flowserve follows for long term storage of pumps is given below. These procedures are in addition to the short term procedure. • Each assembly is hermetically (heat) sealed from the atmosphere by means of tack wrap sheeting and rubber bushings (mounting holes) • Desiccant bags are placed inside the tack wrapped packaging • A solid wood box is used to cover the assembly This packaging will provide protection for up to twelve months from humidity, salt laden air, dust etc. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 After unpacking, protection will be the responsibility of the user. Addition of oil to the bearing housing will remove the inhibitor. If units are to be idle for extended periods after addition of lubricants, inhibitor oils and greases should be used. Every three months, the pump shaft should be rotated approximately 10 revolutions. 3.2 Nomenclature The pump size will be engraved on the nameplate typically as below: 2 K 6 X 4 M - 13 A /12.5 RV • 2.5 Recycling and end of product life At the end of the service life of the product or its parts, the relevant materials and parts should be recycled or disposed of using an environmentally acceptable method and in accordance with local regulations. If the product contains substances that are harmful to the environment, these should be removed and disposed of in accordance with current local regulations. This also includes the liquids and/or gases that may be used in the "seal system" or other utilities. Make sure that hazardous substances are disposed of safely and that the correct personal protective equipment is used. The safety specifications must be in accordance with the current local regulations at all times. • • • • 3 DESCRIPTION 3.1 Configurations The Durco Mark 3 chemical process pumps are metallic , single stage, sealed, centrifugal pumps. The horizontal family conforms to ASME B73.1M, which has a centerline discharge and is represented by our Standard, Sealmatic, Unitized self-priming, Recessed impeller and Lo-Flo pump models. The vertical pump or In-Line conforms to ASME B73.2M. • • Figure 3-1: Nameplate mounted to housing Serial No. Equipment No. Purchase Order Model Size MDP Material Date DD/MMM/YY • 2K6X4 M-13A/12.5 RV • Frame size “2" indicates a medium size pump frame (in this example, a Group 2) 1 = Group 1 (small frame) 2 = Group 2 (medium frame) 3 = Group 3 (large frame) Power end K = Mark 3 style power end Mark 3A – Standard ANSI 3A – Optional (3 year guarantee) J = Mark 3 style PE arranged for Mark 2 wet end (No letter and no preceding number indicates a Mark 2 power end) “6” = nominal suction port size (in.) “4” = Nominal discharge port size (in.) Modifier for “specialty pumps” Blank or no letter = standard pump M = Sealmatic R = recessed impeller US = unitized self-priming V = vertical In-Line LF = Lo-Flo Nominal maximum impeller diameter. “13” = 13 in. Pump design variation A = This pump has been redesigned from an earlier version. The impeller and casing are no longer interchangeable with the earlier version. H = This pump is designed for a higher flow capacity than another pump with the same basic designation. (Examples: 4X3-10 and 4X3-10H; 6X4-10 and 6X4-10H; 10X8-16 and 10X8-16H. HH = This pump is designed for a higher head than another pump with the same basic designation. (Example: 4X3-13 and 4X3-13HH.) Actual impeller size “12.5” = 12 ½ in. diameter; 8.13 = 8 LQ 10.75 = 10 ¾ in (Previous annotation: 124 = 12 4/8 or 12 ½ in. diameter; 83 = 8 LQ Impeller style RV = reverse vane impeller; OP = Open impeller 3™ The Prima is an ANSI 3A power end adapted to other pump models from Flowserve as well as from other pump manufacturers. Only the information in this manual involving the ANSI 3A power end may be used when Installing, Operating or Maintaining a pump that has been upgraded to a Prima3 ™. All other information regarding the pump type must be obtained from the original pump manufacturer’s User Instructions. Page 11 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 3.3 Design of major parts 3.3.1 Pump casing Removal of the casing is not required when performing maintenance of the rotating element. The pump is designed with a gasket perpendicular to the shaft allowing the rotating element to be easily removed (back pull out). 3.3.2 Impeller Depending on the product, the impeller is either reverse vane or open. 3.3.3 Shaft/sleeve Solid and sleeved shafts are available, supported on bearings, threaded impeller end and keyed drive end. 3.3.4 Pump bearings and lubrication Ball bearings are fitted as standard and may be either oil or grease lubricated. 3.3.5 Bearing housing Large oil bath reservoir. 3.3.6 Seal chamber (cover plate) The seal chamber has a spigot (rabbet) fit between the pump casing and bearing housing (adapter) for optimum concentricity. The design enables a number of sealing options to be fitted. 3.3.7 Shaft seal The mechanical seal(s), attached to the pump shaft, seals the pumped liquid from the environment. Gland packing may be fitted as an option. 3.3.8 Driver The driver is normally an electric motor. Different drive configurations may be fitted such as internal combustion engines, turbines, hydraulic motors etc driving via couplings, belts, gearboxes, drive shafts etc. 3.3.9 Accessories Accessories may be fitted when specified by the customer. 3.4 Performance and operation limits This product has been selected to meet the specification of your purchase order. See section 1.5. The following data is included as additional information to help with your installation. It is typical, and factors such as liquid being pumped, temperature, material of construction, and seal type may influence this data. If required, a definitive statement for your application can be obtained from Flowserve. Page 12 of 68 3.4.1 Alloy cross reference chart Figure 3-2 is the Alloy cross-reference chart for all Mark 3 pumps. 3.4.2 Pressure-temperature ratings The pressure-temperature (P-T) ratings for Mark 3 pumps are shown in figures 3-3 and 3-4. Determine the appropriate casing “Material Group No.” in Figure 3-2. Interpolation may be used to find the pressure rating for a specific temperature. Example: The pressure temperature rating for an ANSI standard GP2-10 in. pump with Class 300 flanges and CF8M construction at an operating temperature of 149 Û&LVIRXQGDVIROORZV a) The correct pressure-temperature chart is Figure 3-4C. b) From Figure 3-2, the correct material group for CF8M is 2.2. c) From Figure 3-4C, the pressure-temperature rating is 21.5 bar. The maximum discharge pressure must be less than or equal to the P-T rating. Discharge pressure may be approximated by adding the suction pressure and the differential head developed by the pump. 3.4.3 Suction pressure limits The suction pressure limits for Mark 3 pumps with reverse vane impellers is limited by the values given in figure 3-5 and by the P-T ratings. Suction pressure for pump sizes 10x8-14, 8x6-16A, 10x8-16 and 10x8-16H (up to a maximum liquid specific gravity of 2.0) is limited only by the P-T ratings. Suction pressure for pumps with open impellers is also limited only by the P-T ratings. The suction pressure limits for Sealmatic pumps are determined by the repeller head capability found in Bulletin P-18-102e. 3.4.4 Minimum continuous flow The minimum continuous flow (MCF) is based on a percentage of the best efficiency point (BEP). Figure 3-7 identifies the MCF for all Mark 3 pump models with the exception of the Lo-Flo pump line; there is no MCF associated with this product line. 3.4.5 Minimum suction pipe submergence The minimum submergence is shown in figure 3-8 and 3-9 for Unitized self-priming pumps. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Figure 3-2: Alloy cross-reference chart Flowserve Durco legacy ACI Equivalent wrought Designation material code codes designation designation E3020 Ductile iron DCI None None E3033 High chrome iron CR28 None None E4027 High chrome iron CR29 None None E4028 High chrome iron CR35 None None C3009 Carbon steel DS None Carbon steel C3062 Durco CF8 D2 CF8 304 C3069 Durco CF3 D2L CF3 304L C3063 Durco CF8M D4 CF8M 316 C3067 Durco CF3M D4L CF3M 316L C3107 Durcomet 100 CD4M CD4MCuN Ferralium C4028 Durimet 20 D20 CN7M Alloy 20 C4029 Durcomet 5 DV None None K3005 Durco CY40 DINC CY40 Inconel 600 K3007 Durco M35 DMM M351 Monel 400 K3008 Nickel DNI CZ100 Nickel 200 K4007 Chlorimet 2 DC2 N7M Hastelloy B K4008 Chlorimet 3 DC3 CW6M Hastelloy C E3041 D None None Duriron E3042 D51 None None Durichlor 51 E4035 SD51 None None Superchlor D4036 Durco DC8 DC8 None None H3004 Titanium Ti None Titanium H3005 Titanium-Pd TiP None Titanium-Pd H3007 Zirconium Zr None Zirconium Duriron, Durichlor 51 and Superchlor are registered trademarks of Flowserve Corporation. Ferralium is a registered trademark of Langley Alloys. Hastelloy is a registered trademark of Haynes International, Inc. Inconel and Monel are registered trademarks of International Nickel Co. Inc. ASTM specifications A395, Gr. 60-40-18 A532 class 3 None None A216 Gr. WCB A744, Gr. CF8 A744, Gr. CF3 A744, Gr. CF8M A744, Gr. CF3M A995, Gr. CD4MCuN A744, Gr. CN7M None A494, Gr. CY40 A494, Gr. M35-1 A494, Gr. CZ100 A494, Gr. N7M A494, Gr. CW6M A518, Gr. 1 A518, Gr. 2 A518, Gr. 2 None B367, Gr. C3 B367, Gr. C8A B752, Gr. 702C Material Group No. 1.0 Cr Cr Cr 1.1 2.1 2.1 2.2 2.2 2.8 3.17 2.2 3.5 3.4 3.2 3.7 3.8 No load No load No load Ti Ti Ti Notes: Page 13 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Figure 3-3: Class 150 flanges Temp ºC ( ºF) -73 (-100) -29 (-20) -18 (0) 38 (100) 93 (200) 149 (300) 171 (340) 204 (400) 260 (500) 316 (600) 343 (650) 371 (700) 1.0 1.1 – – 17.2 (250) 17.2 (250) 17.2 (250) 16.2 (235) 14.8 (215) 14.4 (209) 13.8 (200) 11.7 (170) 9.7 (140) 8.6 (125) 19.7 (285) 19.7 (285) 19.7 (285) 17.9 (260) 15.9 (230) 15.0 (218) 13.8 (200) 11.7 (170) 9.7 (140) 8.6 (125) 7.6 (110) – 2.1 2.2 2.8 19.0 (275) 19.0 (275) 19.0 (275) 19.0 (275) 15.9 (230) 14.1 (205) 13.7 (199) 13.1 (190) 11.7 (170) 9.7 (140) 8.6 (125) 7.6 (110) 19.0 (275) 19.0 (275) 19.0 (275) 19.0 (275) 16.2 (235) 14.8 (215) 14.3 (207) 13.4 (195) 11.7 (170) 9.7 (140) 8.6 (125) 7.6 (110) 19.7 (285) 19.7 (285) 19.7 (285) 19.7 (285) 17.9 (260) 15.9 (230) 15.0 (218) 13.8 (200) 11.7 (170) 9.7 (140) – – Material Group No. 3.2 3.4 3.5 bar (psi) 9.7 15.9 15.2 (140) (230) (220) 9.7 15.9 15.2 (140) (230) (220) 9.7 15.9 15.2 (140) (230) (220) 9.7 15.9 15.2 (140) (230) (220) 9.7 13.8 13.8 (140) (200) (200) 9.7 13.1 12.4 (140) (190) (180) 9.7 13.0 12.1 (140) (188) (176) 9.7 12.8 11.7 (140) (185) (170) 9.7 11.7 11.0 (140) (170) (160) 9.7 9.7 9.7 (140) (140) (140) 8.6 8.6 – (125) (125) 7.6 7.6 – (110) (110) 3.7 3.8 3.17 Ti 20.0 (290) 20.0 (290) 20.0 (290) 20.0 (290) 17.9 (260) 15.9 (230) 15.0 (218) 13.8 (200) 11.7 (170) 9.7 (140) 8.6 (125) 7.6 (110) 20.0 (290) 20.0 (290) 20.0 (290) 20.0 (290) 17.9 (260) 15.9 (230) 15.0 (218) 13.8 (200) 11.7 (170) 9.7 (140) 8.6 (125) 7.6 (110) 15.9 (230) 15.9 (230) 15.9 (230) 15.9 (230) 13.8 (200) 12.4 (180) 11.9 (172) 11.0 (160) 10.3 (150) 9.7 (140) 20.0 (290) 20.0 (290) 20.0 (290) 20.0 (290) 17.9 (260) 15.9 (230) 15.0 (218) 13.8 (200) 11.7 (170) 9.7 (140) 8.6 (125) 7.6 (110) – – Cr – – 12.6 (183) 12.6 (183) 12.6 (183) 12.6 (183) 12.6 (183) – – – – – Figure 3-4A: Group 2 – 13 in. In-Lines and Group 3 pumps with Class 300 flanges Temp ºC ( ºF) -73 (-100) -29 (-20) -18 (0) 38 (100) 93 (200) 149 (300) 204 (400) 260 (500) 316 (600) 343 (650) 371 (700) 1.1 – 24.1 (350) 24.1 (350) 24.1 (350) 22.0 (319) 21.4 (310) 20.7 (300) 19.6 (284) 17.9 (260) 17.4 (253) 17.4 (253) Page 14 of 68 2.1 2.2 2.8 24.1 (350) 24.1 (350) 24.1 (350) 24.1 (350) 20.1 (292) 18.1 (263) 16.6 (241) 15.3 (222) 14.6 (211) 14.4 (209) 14.2 (207) 24.1 (350) 24.1 (350) 24.1 (350) 24.1 (350) 20.8 (301) 18.8 (272) 17.3 (250) 16.1 (233) 15.1 (219) 14.9 (216) 14.4 (209) 24.1 (350) 24.1 (350) 24.1 (350) 24.1 (350) 23.2 (336) 21.4 (310) 19.8 (287) 18.5 (268) 17.9 (259) – – Material Group No. 3.2 3.4 3.5 bar (psi) 17.4 24.1 24.1 (252) (350) (350) 17.4 24.1 24.1 (252) (350) (350) 17.4 24.1 24.1 (252) (350) (350) 17.4 24.1 24.1 (252) (350) (350) 17.4 21.3 22.9 (252) (309) (332) 17.4 19.9 21.4 (252) (289) (310) 17.4 19.3 19.9 (252) (280) (288) 17.4 19.1 19.3 (252) (277) (280) 17.4 19.1 19.2 (252) (277) (278) 19.1 19.0 – (277) (276) 19.1 18.9 – (277) (274) 3.7 3.8 3.17 Ti 24.1 (350) 24.1 (350) 24.1 (350) 24.1 (350) 24.1 (350) 23.5 (341) 22.7 (329) 21.4 (310) 19.5 (282) 19.0 (275) 18.3 (266) 24.1 (350) 24.1 (350) 24.1 (350) 24.1 (350) 24.1 (350) 23.5 (341) 22.7 (329) 21.4 (310) 19.5 (282) 19.0 (275) 18.3 (266) 24.1 (350) 24.1 (350) 24.1 (350) 24.1 (350) 20.9 (303) 18.7 (271) 16.9 (245) 15.7 (228) 14.5 (210) 24.1 (350) 24.1 (350) 24.1 (350) 24.1 (350) 21.4 (310) 18.7 (271) 15.9 (231) 13.2 (191) 10.5 (152) 9.1 (132) 7.7 (112) – – flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Figure 3-4B: Group 2 - 13 in. Lo-Flo pumps with Class 300 flanges Temp ºC ( ºF) -73 (-100) -29 (-20) -18 (0) 38 (100) 93 (200) 149 (300) 204 (400) 260 (500) 316 (600) 343 (650) 371 (700) 1.0 1.1 – – 31.0 (450) 31.0 (450) 31.0 (450) 29.1 (422) 27.4 (397) 25.5 (369) 24.0 (348) 22.5 (327) 21.8 (316) 31.0 (450) 31.0 (450) 31.0 (450) 28.3 (410) 27.5 (398) 26.6 (386) 25.2 (365) 23.1 (334) 22.4 (325) 22.4 (325) – 2.1 2.2 2.8 31.0 (450) 31.0 (450) 31.0 (450) 31.0 (450) 25.9 (375) 23.3 (338) 21.3 (309) 19.7 (285) 18.7 (272) 18.5 (269) 18.3 (266) 31.0 (450) 31.0 (450) 31.0 (450) 31.0 (450) 26.7 (388) 24.1 (350) 22.2 (322) 20.7 (300) 19.4 (281) 19.2 (2780 18.5 (269) 31.0 (450) 31.0 (450) 31.0 (450) 31.0 (450) 29.8 (432) 27.5 (399) 25.4 (369) 23.8 (345) 23.0 (333) – – Material Group No. 3.2 3.4 bar (psi) 17.4 24.1 (252) (350) 17.4 24.1 (252) (350) 17.4 24.1 (252) (350) 17.4 24.1 (252) (350) 17.4 21.3 (252) (309) 17.4 19.9 (289) (252) 17.4 19.3 (280) (252) 17.4 19.1 (277) (252) 17.4 19.1 (277) (252) 19.1 – (277) 19.1 – (277) 3.5 3.7 3.8 3.17 Ti 27.6 (400) 27.6 (400) 27.6 (400) 27.6 (400) 26.1 (379) 24.4 (354) 22.7 (330) 22.1 (320) 21.9 (318) 21.8 (316) 21.6 (313) 31.0 (450) 31.0 (450) 31.0 (450) 31.0 (450) 31.0 (450) 30.2 (438) 29.2 (423) 27.5 (399) 25.0 (363) 24.4 (354) 23.6 (342) 31.0 (450) 31.0 (450) 31.0 (450) 31.0 (450) 31.0 (450) 30.2 (438) 29.2 (423) 27.5 (399) 25.0 (363) 24.4 (354) 23.6 (342) 24.1 (350) 24.1 (350) 24.1 (350) 24.1 (350) 20.9 (303) 18.7 (271) 16.9 (245) 15.7 (228) 14.5 (210) 31.0 (450) 31.0 (450) 31.0 (450) 31.0 (450) 27.5 (399) 24.0 (348) 20.5 (297) 17.0 (246) 13.4 (195) 11.7 (170) 9.9 (144) – – Figure 3-4C: All other Class 300 flanges Temp ºC ( ºF) -73 (-100) -29 (-20) -18 (0) 38 (100) 93 (200) 149 (300) 204 (400) 260 (500) 316 (600) 343 (650) 371 (700) 1.1 – 27.6 (400) 27.6 (400) 27.6 (400) 25.2 (365) 24.4 (354) 23.7 (343) 22.4 (324) 20.5 (297) 19.9 (289) 19.9 (289) Page 15 of 68 2.1 2.2 2.8 27.6 (400) 27.6 (400) 27.6 (400) 27.6 (400) 23.0 (333) 20.7 (300) 19.0 (275) 17.5 (253) 16.7 (242) 16.5 (239) 16.3 (236) 27.6 (400) 27.6 (400) 27.6 (400) 27.6 (400) 23.7 (344) 21.5 (311) 19.7 (286) 18.4 (267) 17.2 (250) 17.0 (247) 16.5 (239) 27.6 (400) 27.6 (400) 27.6 (400) 27.6 (400) 26.5 (384) 24.5 (355) 22.6 (328) 21.1 (307) 20.4 (296) – – Material Group No. 3.2 3.4 3.5 bar (psi) 17.4 24.1 24.1 (252) (350) (350) 17.4 24.1 24.1 (252) (350) (350) 17.4 24.1 24.1 (252) (350) (350) 17.4 24.1 24.1 (252) (350) (350) 17.4 21.3 22.9 (252) (309) (332) 17.4 19.9 21.4 (252) (289) (310) 17.4 19.3 19.9 (252) (280) (288) 17.4 19.1 19.3 (252) (277) (280) 17.4 19.1 19.2 (252) (277) (278) 19.1 19.0 – (277) (276) 19.1 18.9 – (277) (274) 3.7 3.8 3.17 Ti 27.6 (400) 27.6 (400) 27.6 (400) 27.6 (400) 27.6 (400) 26.8 (389) 25.9 (376) 24.5 (355) 22.2 (323) 21.7 (315) 21.0 (304) 27.6 (400) 27.6 (400) 27.6 (400) 27.6 (400) 27.6 (400) 26.8 (389) 25.9 (376) 24.5 (355) 22.2 (323) 21.7 (315) 21.0 (304) 24.1 (350) 24.1 (350) 24.1 (350) 24.1 (350) 20.9 (303) 18.7 (271) 16.9 (245) 15.7 (228) 14.5 (210) 27.6 (400) 27.6 (400) 27.6 (400) 27.6 (400) 24.5 (355) 21.3 (309) 18.2 (264) 15.1 (219) 12.0 (173) 10.4 (151) 8.8 (128) – – flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Figure 3-5a: Suction pressure limits 1 750 r/min 400 27.5 11 360 10 22.5 9 20 7 4 17.5 320 8 6 280 5 240 15 200 12.5 160 10 120 3 7.5 80 5 Maximum Allowable Suction Pressure - psi Maximum Allowable Suction Pressure - bar 25 40 2.5 1 0 0.4 0.8 1.2 2 1.6 2 0 2.4 Specific Gravity 27.5 400 25 360 22.5 320 20 17.5 18 280 17 240 15 200 16 12.5 15 10 14 13 7.5 12 11 160 120 80 5 10 3 2.5 40 1 0 0.4 0.8 Maximum Allowable Suction Pressure - psi Maximum Allowable Suction Pressure - bar Figure 3-5b: Suction pressure limits 3 500 r/min 2 1.2 4 5 6 1.6 7 8 2 9 0 2.4 Specific Gravity Page 16 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Figure 3-6: Suction pressure reference numbers Pump size 1 750 1K 1.5x1-6 7 10 1K 3x1.5-6 10 15 1K 3x2-6 10 12 PT 1K 2 x1.5V-6 18 1K 1.5x1-8 7 6 1K 1.5x1.5US-8 PT 1K 2x1.5V-8 16 1K 3x1.5-8 4 4 PT 1K 3x2V-7 11 2K 3x2-8 10 7 2K 4x3-8 10 13 2K 2x1-10A 8 3 2K 2x1.5V-10A 8 3 2K 2x1.5US-10A 2K 3x1.5-10A 10 17 2K 3x2-10A 10 14 2K 3x2V-10 In-Line 11 9 2K 4x3-10 6 2 na 2K 4x3-10H 3 2K 6x4-10 5 8 na 2K 6x4-10H 10 2K 3x1.5-13 9 5 2K 3x2-13 5 1 na 2K 4x3-13/13 1 na 2K 4x3-13/12 1 2K 4x3-13/11 max 1 2 na 2K 4x3-13HH 10 na 2K 6x4-13A 1 ? 2K 6x4-13A/10.25 1 na 3K 8x6-14A 2 PT na 3K 10x8-14 PT na 3K 6x4-16 PT na 3K 8x6-16A PT na 3K 10x8-16 & 16H na 3K 10x8-17 3 PT PT Recessed impellers PT PT Lo-Flo pumps PT PT Open impellers Notes: 1. Self-Primer and In-Line pumps not specifically listed above are to use the standard pump ratings given. For example: 2K 3x2V-13 and 2K 3x2US-13 pumps utilize the standard 2K 3x2-13 ratings. 2. P-T: Only limited by Pressure-Temperature ratings. 3. Open impeller pumps including the Lo-Flo and Recessed Impeller products are limited in suction pressure only by the Pressure-Temperature ratings. 4. Sealmatic pump suction pressure is limited by the repeller. Page 17 of 68 Figure 3-7: Minimum continuous flow 3 500 Pump size 1K3x2-6 1K3x2-7 2K3x2-8 2K4x3-8 2K3x2-10 2K4x3-10 2K6x4-10 2K6x4-10H 2K3x1.5-13 2K3x2-13 2K4x3-13 2K4x3-13HH 2K6x4-13 3K8x6-14 3K10x8-14 3K6x4-16 3K8x6-16 3K10x8-16 3K10x8-17 All other sizes 3 500/2 900 r/min 20% 25% 20% 20% 30% 30% 40% n.a. 30% 40% 40% n.a. 60% n.a. n.a. n.a. n.a. n.a. n.a. 10% MCF % of BEP 1 750/1 450 r/min 10% 10% 10% 10% 10% 10% 10% 20% 10% 10% 20% 50% 40% 40% 40% 50% 50% 50% 50% 10% 1 180/960 r/min 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 30% 10% 15% 10% 10% 10% 10% 10% 10% Figure 3-8: Minimum submergence Figure 3-9: Minimum submergence flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 4 INSTALLATION Zirconium 702 or high chrome iron components If any of the components of the pump have been made of zirconium or high chrome iron, the following precautionary measures should be followed: • Use hand wrenches rather than impact wrenches • This equipment should not be subjected to sudden changes in temperature or pressure • Avoid striking this equipment with any sharp blows Zirconium 705 and high chrome iron components The most advantageous method is the one that permits the pump to move with the piping. This eliminates problems due to thermal expansion, as the pump is designed to withstand forces that the piping is normally capable of transmitting. 4.3.3 Rigid baseplates - overview The function of a baseplate is to provide a rigid foundation under a pump and its driver that maintains alignment between the two. Baseplates may be generally classified into two types: • Foundation-mounted, grouted design. (Figure 4-1.) • Stilt mounted, or free standing. (Figure 4-2.) Figure 4-1 Avoid any repair or fabrication welds on Zirconium 705 and high chrome iron components. 4.1 Location The pump should be located to allow room for access, ventilation, maintenance, and inspection with ample headroom for lifting and should be as close as practicable to the supply of liquid to be pumped. Refer to the general arrangement drawing for the pump set. Figure 4-2 4.2 Part assemblies The supply of motors and baseplates are optional. As a result, it is the responsibility of the installer to ensure that the motor is assembled to the pump and aligned as detailed in section 4.5 and 4.8. 4.3 Foundation 4.3.1 Protection of openings and threads When the pump is shipped, all threads and all openings are covered. This protection/covering should not be removed until installation. If, for any reason, the pump is removed from service, this protection should be reinstalled. 4.3.2 In-Line pump mounting The Mark 3 In-Line can be supported in several ways: • The pump may be supported by the piping; in which case it is recommended that the suction and discharge pipes be supported adjacent to the pump nozzles • The pump may be supported under the casing foot or on the optional “pump stand” The “pump stand” will allow the pump to free stand without the aid of piping. The pump stand may be bolted (and grouted) into place. In this case, the piping loads must be within the limits of the casing and of the “pump stand” as found in section 4.6. Page 18 of 68 Baseplates intended for grouted installation are designed to use the grout as a stiffening member. Stilt mounted baseplates, on the other hand, are designed to provide their own rigidity. Therefore the designs of the two baseplates are usually different. Regardless of the type of baseplate used, it must provide certain functions that ensure a reliable installation. Three of these requirements are: 1. The baseplate must provide sufficient rigidity to assure the assembly can be transported and installed, given reasonable care in handling, without damage. It must also be rigid enough when properly installed to resist operating loads. 2. The baseplate must provide a reasonably flat mounting surface for the pump and driver. Uneven surfaces will result in a soft-foot condition that may make alignment difficult or impossible. Experience indicates that a baseplate with a top surface flatness of 1.25 mm/m (0.015 in./ft) across the diagonal corners of the baseplate provides such a mounting surface. Therefore, this is the tolerance to which we supply our standard baseplate. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Some users may desire an even flatter surface, which can facilitate installation and alignment. Flowserve will supply flatter baseplates upon request at extra cost. For example, mounting surface flatness of 0.17 mm/m (0.002 in./ft) is offered on the Flowserve Type E “Ten Point” baseplate shown in figure 4-1. 3. The baseplate must be designed to allow the user to final field align the pump and driver to within their own particular standards and to compensate for any pump or driver movement that occurred during handling. Normal industry practice is to achieve final alignment by moving the motor to match the pump. Flowserve practice is to confirm in our shop that the pump assembly can be accurately aligned. Before shipment, the factory verifies that there is enough horizontal movement capability at the motor to obtain a “perfect” final alignment when the installer puts the baseplate assembly into its original, top leveled, unstressed condition. 4.3.4 Stilt and spring mounted baseplates Flowserve offers stilt and spring mounted baseplates. (See figure 4-2 for stilt mounted option.) The low vibration levels of Mark 3 pumps allow the use of these baseplates - provided they are of a rigid design. The baseplate is set on a flat surface with no tie down bolts or other means of anchoring it to the floor. General instructions for assembling these baseplates are given below. For dimensional information, please refer to the appropriate Flowserve “Sales print.” 4.3.4.1 Stilt mounted baseplate assembly instructions Refer to figure 4-3. a) Raise or block up baseplate/pump above the floor to allow for the assembly of the stilts. b) Predetermine or measure the approximate desired height for the baseplate above the floor. c) Set the bottom nuts [2] above the stilt bolt head [1] to the desired height. d) Assemble lock washer [3] down over the stilt bolt. e) Assemble the stilt bolt up through hole in the bottom plate and hold in place. f) Assemble the lock washer [3] and nut [2] on the stilt bolt. Tighten the nut down on the lock washer. g) After all four stilts have been assembled, position the baseplate in place, over the floor cups [4] under each stilt location, and lower the baseplate to the floor. h) Level and make final height adjustments to the suction and discharge pipe by first loosening the top nuts and turning the bottom nuts to raise or lower the baseplate. Page 19 of 68 i) j) Tighten the top and bottom nuts at the lock washer [3] first then tighten the other nuts. It should be noted that the connecting pipelines must be individually supported, and that the stilt mounted baseplate is not intended to support total static pipe load. Figure 4-3 4.3.4.2 Stilt/spring mounted baseplate assembly instructions Refer to figure 4-4. a) Raise or block up baseplate/pump above the floor to allow for the assembly of the stilts. b) Set the bottom nuts [4] above the stilt bolt head [1]. This allows for 51 mm (2 in.) upward movement for the final height adjustment of the suction/discharge flange. c) Assemble the lock washer [6] flat washer [5] and bottom spring/cup assembly [2] down over the stilt bolt [1]. d) Assemble the stilt bolt/bottom spring up through hole in the bottom plate and hold in place. e) Assemble top spring/cup assembly [3] down over stilt bolt. f) Assemble flat washer [5], lock washer [6] and nuts [4] on the stilt bolt. g) Tighten down top nuts, compressing the top spring approximately 13 mm (0.5 in.). Additional compression may be required to stabilize the baseplate. h) After all four stilts have been assembled, position the baseplate in place, over the floor cups [7] under each stilt location, and lower the baseplate down to the floor. i) Level and make final height adjustments to the suction and discharge pipe by first loosening the top nuts, and turning the bottom nuts to raise or lower the baseplate. j) Recompress the top spring to the compression established in step g) and lock the nuts. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 k) It should be noted that the connecting pipelines must be individually supported, and that the spring mounted baseplate is not intended to support total static pipe loads. Figure 4-4 4.4 Grouting a) b) c) The pump foundation should be located as close to the source of the fluid to be pumped as practical. There should be adequate space for workers to install, operate, and maintain the pump. The foundation should be sufficient to absorb any vibration and should provide a rigid support for the pump and motor. Recommended mass of a concrete foundation should be three times that of the pump, motor and base. Refer to figure 4-5. Foundation bolts are imbedded in the concrete inside a sleeve to allow some movement of the bolt. Figure 4-5 4.3.4.3 Stilt/spring mounted baseplates - motor alignment The procedure for motor alignment on stilt or spring mounted baseplates is similar to grouted baseplates. The difference is primarily in the way the baseplate is leveled. a) Level the baseplate by using the stilt adjusters. (Shims are not needed as with grouted baseplates.) b) After the base is level, it is locked in place by locking the stilt adjusters. c) Next the initial pump alignment must be checked. The vertical height adjustment provided by the stilts allows the possibility of slightly twisting the baseplate. If there has been no transit damage or twisting of the baseplate during stilt height adjustment, the pump and driver should be within 0.38 mm (0.015 in.) parallel, and 0.0025 mm/mm (0.0025 in./in.) angular alignment. If this is not the case, check to see if the driver mounting fasteners are centered in the driver feet holes. d) If the fasteners are not centered there was likely shipping damage. Re-center the fasteners and perform a preliminary alignment to the above tolerances by shimming under the motor for vertical alignment, and by moving the pump for horizontal alignment. e) If the fasteners are centered, then the baseplate may be twisted. Slightly adjust (one turn of the adjusting nut) the stilts at the driver end of the baseplate and check for alignment to the above tolerances. Repeat as necessary while maintaining a level condition as measured from the pump discharge flange. f) Lock the stilt adjusters. The remaining steps are as listed for new grouted baseplates. Page 20 of 68 d) e) Level the pump baseplate assembly. If the baseplate has machined coplanar mounting surfaces, these machined surfaces are to be referenced when leveling the baseplate. This may require that the pump and motor be removed from the baseplate in order to reference the machined faces. If the baseplate is without machined coplanar mounting surfaces, the pump and motor are to be left on the baseplate. The proper surfaces to reference when leveling the pump baseplate assembly are the pump suction and discharge flanges. DO NOT stress the baseplate. Do not bolt the suction or discharge flanges of the pump to the piping until the baseplate foundation is completely installed. If equipped, use leveling jackscrews to level the baseplate. If jackscrews are not provided, shims and wedges should be used. (See Figure 4-5.) Check for levelness in both the longitudinal and lateral directions. Shims should be placed at all base anchor bolt locations, and in the middle edge of the base if the base is more than 1.5 m (5 ft.) long. Do not rely on the bottom of the baseplate to be flat. Standard baseplate bottoms are not machined, and it is not likely that the field mounting surface is flat. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 f) g) h) i) j) k) After leveling the baseplate, tighten the anchor bolts. If shims were used, make sure that the baseplate was shimmed near each anchor bolt before tightening. Failure to do this may result in a twist of the baseplate, which could make it impossible to obtain final alignment. Check the level of the baseplate to make sure that tightening the anchor bolts did not disturb the level of the baseplate. If the anchor bolts did change the level, adjust the jackscrews or shims as needed to level the baseplate. Continue adjusting the jackscrews or shims and tightening the anchor bolts until the baseplate is level. Check initial alignment. If the pump and motor were removed from the baseplate proceed with step j) first, then the pump and motor should be reinstalled onto the baseplate using Flowserve’s factory preliminary alignment procedure as described in section 4.5, and then continue with the following. As described above, pumps are given a preliminary alignment at the factory. This preliminary alignment is done in a way that ensures that, if the installer duplicates the factory conditions, there will be sufficient clearance between the motor hold down bolts and motor foot holes to move the motor into final alignment. If the pump and motor were properly reinstalled to the baseplate or if they were not removed from the baseplate and there has been no transit damage, and also if the above steps where done properly, the pump and driver should be within 0.38 mm (0.015 in.) FIM (Full Indicator Movement) parallel, and 0.0025 mm/mm (0.0025 in./in.) FIM angular. If this is not the case, first check to see if the driver mounting fasteners are centered in the driver feet holes. If not, re-center the fasteners and perform a preliminary alignment to the above tolerances by shimming under the motor for vertical alignment, and by moving the pump for horizontal alignment. Grout the baseplate. A non-shrinking grout should be used. Make sure that the grout fills the area under the baseplate. After the grout has cured, check for voids and repair them. Jackscrews, shims and wedges should be removed from under the baseplate at this time. If they were to be left in place, they could rust, swell, and cause distortion in the baseplate. Run piping to the suction and discharge of the pump. There should be no piping loads transmitted to the pump after connection is made. Recheck the alignment to verify that there are no significant loads. Page 21 of 68 4.5 Initial alignment 4.5.1 Horizontal initial alignment procedure The purpose of factory alignment is to ensure that the user will have full utilization of the clearance in the motor holes for final job-site alignment. To achieve this, the factory alignment procedure specifies that the pump be aligned in the horizontal plane to the motor, with the motor foot bolts centered in the motor holes. This procedure ensures that there is sufficient clearance in the motor holes for the customer to field align the motor to the pump, to zero tolerance. This philosophy requires that the customer be able to place the base in the same condition as the factory. Thus the factory alignment will be done with the base sitting in an unrestrained condition on a flat and level surface. This standard also emphasizes the need to ensure the shaft spacing is adequate to accept the specified coupling spacer. The factory alignment procedure is summarized below: a) The baseplate is placed on a flat and level workbench in a free and unstressed position. b) The baseplate is leveled as necessary. Leveling is accomplished by placing shims under the rails of the base at the appropriate anchor bolt hole locations. Levelness is checked in both the longitudinal and lateral directions. c) The motor and appropriate motor mounting hardware is placed on the baseplate and the motor is checked for any planar soft-foot condition. If any is present it is eliminated by shimming. d) The motor feet holes are centered on the motor mounting fasteners. This is done by using a centering nut as shown in figure 4-6. Figure 4-6 e) The motor is fastened in place by tightening the nuts on two diagonal motor mounting studs. f) The pump is put onto the baseplate and leveled. The foot piece under the bearing housing is adjustable. It is used to level the pump, if necessary. Mark 3A and ANSI 3A design If an adjustment is necessary, add or remove shims [3126.1] between the foot piece and the bearing housing. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Mark 3 design (old) If an adjustment is necessary, the adjuster nut [6576] is used to move the footpiece up or down. g) The spacer coupling gap is verified. h) The parallel and angular vertical alignment is made by shimming under the motor. i) The motor feet holes are again centered on the motor mounting studs using the centering nut. At this point the centering nut is removed and replaced with a standard nut. This gives maximum potential mobility for the motor to be horizontally moved during final, field alignment. All four motor feet are tightened down. j) The pump and motor shafts are then aligned horizontally, both parallel and angular, by moving the pump to the fixed motor. The pump feet are tightened down. k) Both horizontal and vertical alignment is again final checked as is the coupling spacer gap. See section 4.8, Final shaft alignment. Figure 4-7 Figure 4-8 4.5.2 In-Line initial alignment procedure The factory alignment proceed procedure ensures that the unit may be aligned in the field. The initial alignment is no more than 0.38 mm (0.015 in.) parallel, and 0.0025 mm/mm (0.0025 in./in.) angular misalignment. The Mark 3 In-Line incorporates motor alignment capabilities. Parallel alignment is achieved by moving the motor adapter and motor as an assembly relative to the power end. Four adjustment screws (as shown in figures 4-7 and 4-8) allow for precise changes in parallel alignment. Angular alignment is controlled by machining tolerances, but cannot prevent uneven cover gasket compression. a) Check angular alignment. Additional torque may be applied to the appropriate casing bolts to correct angularity. b) Check parallel alignment within a plane defined by the adjusters at opposite corners of the motor adapter. To make corrections, the motor adapter nuts [6580.3] must be slightly loosened to allow the motor adapter to move. All adjusters except for the one in the desired direction of motor movement should be loosened during adjustment. Tighten the adjuster slowly against the stud until desired alignment numbers are reached. c) Check parallel alignment within a plane 90 degrees from the first. Corrections are made as described in the previous step. d) Several iterations between planes may be necessary. Tighten all fasteners and recheck alignment. Page 22 of 68 4.6 Piping Protective covers are fitted to both the suction and discharge flanges of the casing and must be removed prior to connecting the pump to any pipes. 4.6.1 Suction and discharge piping All piping must be independently supported, accurately aligned and preferably connected to the pump by a short length of flexible piping. The pump should not have to support the weight of the pipe or compensate for misalignment. It should be possible to install suction and discharge bolts through mating flanges without pulling or prying either of the flanges. All piping must be tight. Pumps may air-bind if air is allowed to leak into the piping. If the pump flange(s) have tapped holes, select flange fasteners with thread engagement at least equal to the fastener diameter but that do not bottom out in the tapped holes before the joint is tight. 4.6.2 Suction piping To avoid NPSH and suction problems, suction piping must be at least as large as the pump suction connection. Never use pipe or fittings on the suction that are smaller in diameter than the pump suction size. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Figure 4-9 illustrates the ideal piping configuration with a minimum of 10 pipe diameters between the source and the pump suction. In most cases, horizontal reducers should be eccentric and mounted with the flat side up as shown in figure 4-10 with a maximum of one pipe size reduction. Never mount eccentric reducers with the flat side down. Horizontally mounted concentric reducers should not be used if there is any possibility of entrained air in the process fluid. Vertically mounted concentric reducers are acceptable. In applications where the fluid is completely de-aerated and free of any vapor or suspended solids, concentric reducers are preferable to eccentric reducers. Figure 4-9 Figure 4-10 Avoid the use of throttling valves and strainers in the suction line. Start up strainers must be removed shortly before start up. When the pump is installed below the source of supply, a valve should be installed in the suction line to isolate the pump and permit pump inspection and maintenance. However, never place a valve directly on the suction nozzle of the pump. Refer to the Durco Pump Engineering Manual and the Centrifugal Pump IOM Section of the Hydraulic Institute Standards for additional recommendations on suction piping. (See section 10.) Refer to section 3.4 for performance and operating limits. 4.6.2.1 Mark 3 Self-Priming Pumps The suction piping must be as short as possible and be as close to the diameter of the suction nozzle as is practical. The pump works by removing the air contained in the suction piping. Once removed, it operates exactly the same as a flooded suction standard pump. Longer and larger the suction pipe have a greater volume of air that has to be removed, resulting in longer priming time. The suction piping and seal chamber must be airtight to allow priming to occur. When possible, it is recommended that suction piping be sloped slightly towards the casing to limit priming fluid loss down the suction line during priming and shutdown. Page 23 of 68 4.6.3 Discharge piping Install a valve in the discharge line. This valve is required for regulating flow and/or to isolate the pump for inspection and maintenance. When fluid velocity in the pipe is high, for example, 3 m/s (10 ft/sec) or higher, a rapidly closing discharge valve can cause a damaging pressure surge. A dampening arrangement should be provided in the piping. 4.6.3.1 Mark 3 Self-Priming Pumps During the priming cycle, air from the suction piping is evacuated into the discharge piping. There must be a way for this air to vent. If air is not able to freely vent out the discharge pipe, it is typically recommended to install an air bleed line. The air bleed line is typically connected from the discharge pipe to the sump. Car must be taken to prevent air from re-entering suction pipe. 4.6.4 Allowable nozzle loads Flowserve chemical process pumps meet or exceed the allowable nozzle loads given by ANSI/HI 9.6.2. The following paragraphs describe how to calculate the allowable loads for each pump type and how to determine if the applied loads are acceptable. The first configuration covered is ASME B73.1M pumps, including the Mark 3 Standard, Sealmatic, Lo-Flo, Recessed Impeller, and Unitized Self-Priming pumps. The second configuration covered is the ASME B73.2M vertical, Mark 3 In-Line pump. 4.6.4.1 Mark 3 horizontal pumps (ASME B73.1M) The following steps are based upon ANSI/HI 9.6.2. All information necessary to complete the evaluation is given below. For complete details please review the standard. a) Determine the appropriate casing “Material Group No.” from figure 3-2. b) Find the “Casing material correction factor” in Figure 4-11 based upon the “Material Group No.” and operating temperature. Interpolation may be used to determine the correction factor for a specific temperature. c) Find the “Baseplate correction factor” in Figure 4-12. The correction factor depends upon how the baseplate is to be installed. d) Locate the pump model being evaluated in Figure 4-16 and multiply each load rating by the casing correction factor. Record the ”adjusted Figure 4-16 loads”. e) Locate the pump model being evaluated in Figures 4-17 and 4-18 and multiply each load rating by the baseplate correction factor. Record the adjusted Figure 4-17 and 4-18 loads. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 f) Compare the “adjusted Figure 4-16 loads” to the values shown in figure 4-15. The lower of these two values should be used as the adjusted figure 415 values. (The HI standard also asks that figure 415 loads be reduced if figure 4-17 or 4-18 values are lower. Flowserve does not follow this step.) g) Calculate the applied loads at the casing flanges according to the coordinate system found in figure 4-13. The 12 forces and moments possible are Fxs, Fys, Fzs, Mxs, Mys, Mzs, Fxd, Fyd, Fzd, Mxd, Myd and Mzd. For example, Fxd designates Force in the “x” direction on the discharge flange. Mys designates the Moment about the “y”-axis on the suction flange. h) Figure 4-14 gives the acceptance criteria equations. For long coupled pumps, equation sets 1 through 5 must be satisfied. For close coupled and C-face pumps, only equation sets 1 and 2 must be satisfied. i) Equation set 1. Each applied load is divided by the corresponding adjusted figure 4-15 value. The absolute value of each ratio must be less than or equal to one. j) Equation set 2. The summation of the absolute values of each ratio must be less than or equal to two. The ratios are the applied load divided by the adjusted figure 4-16 values. k) Equation sets 3 and 4. These equations are checking for coupling misalignment due to nozzle loading in each axis. Each applied load is divided by the corresponding adjusted load from figure 4-17 and 4-18. The result of each equation must be between one and negative one. l) Equation set 5. This equation calculates the total shaft movement from the results of equations 3 and 4. The result must be less than or equal to one. Figure 4-11: Casing material correction factors Material Group No. 1.0 Temp Temp -129 -73 -29 38 93 150 205 260 315 344 370 -200 -100 -20 100 200 300 400 500 600 650 700 Page 24 of 68 DCI – – 0.89 0.89 0.83 0.78 0.73 0.69 0.65 0.63 – 1.1 2.1 Carbon Steel – – 1.00 1.00 0.94 0.91 0.88 0.83 0.76 0.74 0.74 Type 304 and 304L 1.00 1.00 1.00 1.00 0.83 0.75 0.69 0.63 0.60 0.60 0.59 2.2 2.4 Austenitic steels Type 316 Type and 316L 321 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.86 0.93 0.78 0.83 0.72 0.69 0.67 0.64 0.63 0.60 0.62 0.60 0.60 0.58 2.8 3.2 3.4 3.5 3.7 3.8 3.17 Ti Cr Alloy 20 0.83 0.83 0.83 0.83 0.72 0.65 0.58 0.54 0.50 – – Ti, TiPd, Zr – 0.89 0.89 0.89 0.86 0.81 0.69 0.57 0.45 0.39 0.33 High Chrome -18 to 171 340 – – 0.65 0.65 0.65 0.65 0.65 – – – – Nickel and nickel alloys CD4MCu – 1.00 1.00 1.00 1.00 0.92 0.85 0.80 0.77 – – Nickel 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 – – Monel – 0.83 0.83 0.83 0.74 0.69 0.67 0.66 0.66 0.66 0.66 Inconel – 0.93 0.93 0.93 0.88 0.82 0.77 0.74 0.74 0.73 0.73 Hast B – 1.00 1.00 1.00 1.00 1.01 0.98 0.92 0.84 0.82 0.79 Hast C – 1.00 1.00 1.00 1.00 1.01 0.98 0.92 0.84 0.82 0.79 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Figure 4-12: Baseplate correction factors Base type Type A Type B - Polybase Type C Type D Type E - PIP Polyshield - baseplate/ foundation Figure 4-13: Coordinate system Grouted 1.0 1.0 n/a 1.0 1.0 Bolted 0.7 n/a 1.0 0.8 0.95 Stilt mounted 0.65 0.95 1.0 0.75 n/a 1.0 n/a n/a Figure 4-14: Acceptance criteria equations Set 1 Equations Fys M ys Fxs Fzs M xs M zs ≤ 1.0, ≤ 1.0, ≤ 1.0, ≤ 1.0, ≤ 1.0, ≤ 1.0, Fxs _ adj Fys _ adj Fzs _ adj M xs _ adj M ys _ adj M zs _ adj Fyd M yd Fxd Fzd M xd M zd ≤ 1.0, ≤ 1.0, ≤ 1.0, ≤ 1.0, ≤ 1.0, ≤ 1.0 Fxd _ adj Fyd _ adj Fzd _ adj M xd _ adj M yd _ adj M zd _ adj Fxs 2 Fxs _ adj Fys + Fys _ adj Fzs Fzs _ adj + M xs M xs _ adj + M ys M ys _ adj + M zs + M zs _ adj Fyd M yd Fxd Fzd M xd M zd + + + + + ≤ 2.0 Fxd _ adj Fyd _ adj Fzd _ adj M xd _ adj M yd _ adj M zd _ adj A= 3 + Fys + Fys _ adj Fyd Fyd _ adj + Figure Remarks Adjusted 4-15 Maximum individual loading Adjusted 4-16 Nozzle stress, bolt stress, pump slippage Adjusted 4-17 y-axis movement Adjusted 4-18 z-axis movement - Combined axis movement M ys M xs M zs + + + M xs _ adj M ys _ adj M zs _ adj M yd M xd M zd + + M xd _ adj M yd _ adj M zd _ adj −1.0 ≤ A ≤ 1.0 B= 4 Fxs + Fxs _ adj Fxd Fxd _ adj + Fzs Fzs _ adj Fyd Fyd _ adj + + M ys M xs M zs + + + M xs _ adj M ys _ adj M zs _ adj Fzd Fzd _ adj M yd M xd M zd + + + M xd _ adj M yd _ adj M zd _ adj − 1 .0 ≤ B ≤ 1 .0 5 A2 + B 2 ≤ 1.0 Note: All of the above equations are found by dividing the applied piping loads by the adjusted figure values. Page 25 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Figure 4-15: Maximum individual loading Suction flange Pump size 1K 1.5x1-LF4 1K 1.5x1-6 1K 3x1.5-6 1K 3x2-6 1K 1.5x1-8 and LF8 1K 1.5x1.5US-8 1K 3x1.5-8 2K 3x2-8 2K 4x3-8 2K 2x1-10A and LF10 2K 2x1.5US-10A 2K 2x2R-10 2K 3x1.5-10A 2K 3x2-10A 2K 3x2US-10 2K 3x3R-10 2K 4x3-10 and 10H 2K 4x3US-10H 2K 6x4-10 and 10H 2K 3x1.5-13 and LF13 2K 3x2-13 2K 3x2US-13 2K 4x3-13 and 13HH 2K 4x3US-13 2K 4x3R-13 2K 6x4-13A 2K 6x4US-13A 2K 6x4R-13 3K 8x6-14A 3K 10x8-14 3K 6x4-16 3K 8x6-16A 3K 10x8-16 and 16H 3K 10x8-17 Page 26 of 68 Forces N (lbf) Fxs Fys Fzs 4 670 (1 050) 4 670 (1 050) 4 670 (1 050) 4 670 (1 050) 4 670 (1 050) 4 670 (1 050) 4 670 (1 050) 12 010 (2 700) 12 010 (2 700) 10 408 (2 340) 10 408 (2 340) 10 408 (2 340) 12 010 (2 700) 12 010 (2 700) 12 010 (2 700) 12 010 (2 700) 10 230 (2 300) 10 230 (2 300) 12 010 (2 700) 12 010 (2 700) 8 540 (1 920) 8 540 (1 920) 12 010 (2 700) 12 010 (2 700) 12 010 (2 700) 12 010 (2 700) 12 010 (2 700) 12 010 (2 700) 15 568 (3 500) 15 568 (3 500) 15 568 (3 500) 15 568 (3 500) 15 568 (3 500) 15 568 (3 500) 3 336 (750) 3 336 (750) 5 516 (1 240) 4 670 (1 050) 5 382 (1 210) 5 382 (1 210) 5 516 (1 240) 6 005 (1 350) 6 005 (1 350) 4 270 (960) 4 270 (960) 4 270 (960) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 5 471 (1 230) 5 471 (1 230) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 14 145 (3 180) 14 145 (3 180) 12 721 (2 860) 14 145 (3 180) 14 145 (3 180) 14 145 (3 180) 3 336 (750) 3 336 (750) 5 560 (1 250) 4 670 (1 050) 5 382 (1 210) 5 382 (1 210) 5 560 (1 250) 6 672 (1 500) 6 672 (1 500) 4 270 (960) 4 270 (960) 4 270 (960) 6 672 (1 500) 6 583 (1 480) 6 583 (1 480) 6 583 (1 480) 6 672 (1 500) 6 672 (1 500) 6 672 (1 500) 6 672 (1 500) 5 471 (1 230) 5 471 (1 230) 6 672 (1 500) 6 672 (1 500) 6 672 (1 500) 6 672 (1 500) 6 672 (1 500) 6 672 (1 500) 8 896 (2 000) 8 896 (2 000) 8 006 (1 800) 8 896 (2 000) 8 896 (2 000) 8 896 (2 000) Discharge flange Moments Nm (lbf•ft) Mxs Mys Mzs 976 (720) 976 (720) 1 220 (900) 1 220 (900) 976 (720) 976 (720) 1 220 (900) 1 763 (1 300) 1 763 (1 300) 1 722 (1 270) 1 722 (1 270) 1 722 (1 270) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 2 034 (1 500) 2 034 (1 500) 1 831 (1 350) 2 034 (1 500) 2 034 (1 500) 2 034 (1 500) 231 (170) 231 (170) 664 (490) 298 (220) 258 (190) 258 (190) 664 (490) 814 (600) 475 (350) 298 (220) 298 (220) 298 (220) 570 (420) 420 (310) 420 (310) 420 (310) 420 (310) 420 (310) 1 492 (1 100) 909 (670) 475 (350) 475 (350) 542 (400) 542 (400) 542 (400) 1 763 (1 300) 1 763 (1 300) 1 763 (1 300) 1 587 (1 170) 2 712 (2 000) 1 431 (1 055) 2 007 (1 480) 1 532 (1 130) 1 532 (1 130) 231 (170) 231 (170) 664 (490) 298 (220) 258 (190) 258 (190) 664 (490) 814 (600) 475 (350) 298 (220) 298 (220) 298 (220) 570 (420) 420 (310) 420 (310) 420 (310) 420 (310) 420 (310) 1 492 (1 100) 909 (670) 475 (350) 475 (350) 542 (400) 542 (400) 542 (400) 1 492 (1 100) 1 492 (1 100) 1 492 (1 100) 1 587 (1 170) 2 915 (2 150) 1 431 (1 055) 2 007 (1 480) 1 532 (1 130) 1 532 (1 130) Forces N (lbf) Fxd Fyd Fzd 3 558 (800) 3 558 (800) 3 558 (800) 3 558 (800) 3 558 (800) 3 558 (800) 3 558 (800) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 227 (1 400) 6 672 (1 500) 6 672 (1 500) 6 005 (1 350) 6 672 (1 500) 6 672 (1 500) 6 672 (1 500) 6 005 (1350) 6 005 (1350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 13 344 (3 000) 13 344 (3 000) 12 010 (2 700) 13 344 (3 000) 13 344 (3 000) 13 344 (3 000) 13 344 (3 000) 13 344 (3 000) 13 344 (3 000) 13 344 (3 000) 13 344 (3 000) 13 344 (3 000) 13 344 (3 000) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 14 456 (3 250) 15 568 (3 500) 15 568 (3 500) 14 011 (3 150) 15 568 (3 500) 15 568 (3 500) 15 568 (3 500) Moments Nm (lbf•ft) Mxd Myd Mzd 556 (410) 556 (410) 678 (500) 678 (500) 488 (360) 488 (360) 597 (440) 895 (660) 1 627 (1 200) 895 (660) 895 (660) 895 (660) 502 (370) 759 (560) 759 (560) 759 (560) 1 627 (1 200) 1 627 (1 200) 1 627 (1 200) 719 (530) 1 627 (1 200) 1 627 (1 200) 1 627 (1 200) 1 627 (1 200) 1 627 (1 200) 1 627 (1 200) 1 627 (1 200) 1 627 (1 200) 1 695 (1 250) 1 695 (1 250) 1 526 (1 125) 1 695 (1 250) 1 695 (1 250) 1 695 (1 250) 556 (410) 556 (410) 746 (550) 1 356 (1 000) 488 (360) 488 (360) 597 (440) 895 (660) 1 980 (1 460) 895 (660) 895 (660) 895 (660) 502 (370) 759 (560) 759 (560) 759 (560) 1 980 (1 460) 1 980 (1 460) 2 034 (1 500) 719 (530) 1 722 (1 270) 1 722 (1 270) 2 034 (1 500) 2 034 (1 500) 2 034 (1 500) 2 034 (1 500) 2 034 (1 500) 2 034 (1 500) 3 851 (2 840) 3 851 (2 840) 3 465 (2 555) 3 851 (2 840) 3 851 (2 840) 3 851 (2 840) 556 (410) 556 (410) 692 (510) 692 (510) 488 (360) 488 (360) 597 (440) 895 (660) 936 (690) 895 (660) 895 (660) 895 (660) 502 (370) 759 (560) 759 (560) 759 (560) 936 (690) 936 (690) 936 (690) 719 (530) 936 (690) 936 (690) 936 (690) 936 (690) 936 (690) 936 (690) 936 (690) 936 (690) 3 851 (2 840) 3 851 (2 840) 3 465 (2 555) 3 851 (2 840) 3 851 (2 840) 3 851 (2 840) flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Figure 4-16: Maximum combined loading Suction flange Pump size 1K 1.5x1-LF4 1K 1.5x1-6 1K 3x1.5-6 1K 3x2-6 1K 1.5x1-8 and LF-8 1K 1.5x1.5US-8 1K 3x1.5-8 2K 3x2-8 2K 4x3-8 2K 2x1-10A and LF10 2K 2x1.5US-10A 2K 2x2R-10 2K 3x1.5-10A 2K 3x2-10A 2K 3x2US-10 2K 3x3R-10 2K 4x3-10 and 10H 2K 4x3US-10H 2K 6x4-10 and 10H 2K 3x1.5-13 and LF13 2K 3x2-13 2K 3x2US-13 2K 4x3-13 and 13HH 2K 4x3US-13 2K 4x3R-13 2K 6x4-13A 2K 6x4US-13A 2K 6x4R-13 3K 8x6-14A 3K 10x8-14 3K 6x4-16 3K 8x6-16A 3K 10x8-16 & 16HH 3K 10x8-17 Page 27 of 68 Forces N (lbf) Fxs Fys Fzs 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 12 010 (2 700) 12 010 (2 700) 10 408 (2 340) 10 408 (2 340) 10 408 (2 340) 12 010 (2 700) 12 010 (2 700) 12 010 (2 700) 12 010 (2 700) 10 230 (2 300) 10 230 (2 300) 12 010 (2 700) 12 010 (2 700) 8 540 (1 920) 8 540 (1 920) 12 010 (2 700) 12 010 (2 700) 12 010 (2 700) 12 010 (2 700) 12 010 (2 700) 12 010 (2 700) 28 289 (6 360) 28 289 (6 360) 28 289 (6 360) 28 289 (6 360) 28 289 (6 360) 28 289 (6 360) 3 336 (750) 3 336 (750) 5 516 (1 240) 4 670 (1 050) 5 382 (1 210) 5 382 (1 210) 5 516 (1 240) 6 005 (1 350) 6 005 (1 350) 4 270 (960) 4 270 (960) 4 270 (960) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 5 471 (1 230) 5 471 (1 230) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 14 145 (3 180) 14 145 (3 180) 14 145 (3 180) 14 145 (3 180) 14 145 (3 180) 14 145 (3 180) 3 336 (750) 3 336 (750) 9 385 (2 110) 4 670 (1 050) 5 382 (1 210) 5 382 (1 210) 7 295 (1 640) 11 076 (2 490) 8 184 (1 840) 4 270 (960) 4 270 (960) 4 270 (960) 8 496 (1 910) 6 583 (1 480) 6 583 (1 480) 6 583 (1 480) 7 295 (1 640) 7 295 (1 640) 27 756 (6 240) 13 611 (3 060) 5 471 (1 230) 5 471 (1 230) 10 631 (2 390) 10 631 (2 390) 10 631 (2 390) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 22 596 (5 080) 59 870 (13 460) 20 327 (4 570) 29 713 (6 680) 22 818 (5 130) 22 818 (5 130) Discharge flange Moments Nm (lbf•ft) Mxs Mys Mzs 2 481 (1 830) 2 481 (1 830) 3 105 (2 290) 3 105 (2 290) 2 481 (1 830) 2 481 (1 830) 3 105 (2 290) 5 058 (3 730) 5 058 (3 730) 4 936 (3 640) 4 936 (3 640) 4 936 (3 640) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 5 058 (3 730) 12 163 (8 970) 12 163 (8 970) 12 163 (8 970) 12 163 (8 970) 12 163 (8 970) 12 163 (8 970) 231 (170) 231 (170) 664 (490) 298 (220) 258 (190) 258 (190) 664 (490) 814 (600) 475 (350) 298 (220) 298 (220) 298 (220) 570 (420) 420 (310) 420 (310) 420 (310) 420 (310) 420 (310) 1 492 (1 100) 909 (670) 475 (350) 475 (350) 542 (400) 542 (400) 542 (400) 6 753 (4 980) 6 753 (4 980) 6 753 (4 980) 1 587 (1 170) 3 322 (2 450) 1 431 (1 055) 2 007 (1 480) 1 532 (1 130) 1 532 (1 130) 231 (170) 231 (170) 664 (490) 298 (220) 258 (190) 258 (190) 664 (490) 814 (600) 475 (350) 298 (220) 298 (220) 298 (220) 570 (420) 420 (310) 420 (310) 420 (310) 420 (310) 420 (310) 1 492 (1 100) 909 (670) 475 (350) 475 (350) 542 (400) 542 (400) 542 (400) 1 492 (1 100) 1 492 (1 100) 1 492 (1 100) 1 587 (1 170) 2 915 (2 150) 1 431 (1 055) 2 007 (1 480) 1 532 (1 130) 1 532 (1 130) Forces N (lbf) Fxd Fyd Fzd 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 763 (1 970) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 629 (1 940) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 8 985 (2 020) 28 289 (6 360) 28 289 (6 360) 25 465 (5 725) 28 289 (6 360) 28 289 (6 360) 28 289 (6 360) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 6 005 (1 350) 14 145 (3 180) 14 145 (3 180) 12 720 (2 860) 14 145 (3 180) 14 145 (3 180) 14 145 (3 180) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 27 756 (6 240) 59 870 (13 460) 59 870 (13 460) 53 888 (12 115) 59 870 (13 460) 59 870 (13 460) 59 870 (13 460) Moments Nm (lbf•ft) Mxd Myd Mzd 556 (410) 556 (410) 746 (550) 1 397 (1 030) 488 (360) 488 (360) 597 (440) 895 (660) 1 980 (1 460) 895 (660) 895 (660) 895 (660) 502 (370) 759 (560) 759 (560) 759 (560) 1 980 (1 460) 1 980 (1 460) 4 204 (3 100) 719 (530) 1 980 (1 460) 1 980 (1 460) 2 346 (1 730) 2 346 (1 730) 2 346 (1 730) 2 915 (2 150) 2 915 (2 150) 2 915 (2 150) 9 194 (6 780) 12 163 (8 970) 8 272 (6 100) 8 895 (6 560) 12 163 (8 970) 12 163 (8 970) 556 (410) 556 (410) 746 (550) 1 397 (1 030) 488 (360) 488 (360) 597 (440) 895 (660) 1 980 (1 460) 895 (660) 895 (660) 895 (660) 502 (370) 759 (560) 759 (560) 759 (560) 1 980 (1 460) 1 980 (1 460) 4 204 (3 100) 719 (530) 1 980 (1 460) 1 980 (1 460) 2 346 (1 730) 2 346 (1 730) 2 346 (1 730) 2 915 (2 150) 2 915 (2 150) 2 915 (2 150) 5 221 (3 850) 9 790 (7 220) 4 699 (3 465) 5 044 (3 720) 12 285 (9 060) 12 285 (9 060) 556 (410) 556 (410) 692 (510) 692 (510) 488 (360) 488 (360) 597 (440) 895 (660) 936 (690) 895 (660) 895 (660) 895 (660) 502 (370) 759 (560) 759 (560) 759 (560) 936 (690) 936 (690) 936 (690) 719 (530) 936 (690) 936 (690) 936 (690) 936 (690) 936 (690) 936 (690) 936 (690) 936 (690) 3 851 (2 840) 3 851 (2 840) 3 465 (2 555) 3 851 (2 840) 3 851 (2 840) 3 851 (2 840) flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Figure 4-17: Maximum Y-axis loading for shaft deflection Suction flange Pump size Group 1 Group 2 Group 3 Forces N (lbf) Fxs Fys Fzs -8 896 – – (-2 000) -15 568 – – (-3 500) -22 240 – – (-5 000) Discharge flange Moments Nm (lbf•ft) Mxs Mys Mzs 1 220.4 1 627.2 1 695 (900) (1 200) (1 250) 1 762.8 1 762.8 4 068 (1 300) (1 300) (3 000) 2 034 2 712 5 424 (1 500) (2 000) (4 000) Forces N (lbf) Fxd Fyd Fzd 6 672 – – (1 500) 11 120 – – (2 500) 13 344 – – (3 000) Moments Nm (lbf•ft) Mxd Myd Mzd -678 2 034 1 695 (-500) (1 500) (1 250) -1 627 2 034 4 068 (-1 200) (1 500) (3 000) -1 695 6 780 5 424 (-1 250) (5 000) (4 000) Figure 4-18: Maximum Z-axis loading for shaft deflection Suction flange Pump size Group 1 Group 2 Group 3 Forces N (lbf) Fxs Fys Fzs -5 560 4 670 – (-1 250) (1 050) -6 672 15 568 – (-1 500) (3 500) -8 896 15 568 – (-2 000) (3 500) 4.6.4.2 Mark 3 In-Line pumps (ASME B73.2M) 4.6.4.2a Pump mounting Review Pump mounting, section 4.3. The pump may be mounted such that it is free to move with the piping. The pump may be supported by the piping, so that it is free to move in all directions. The pump may also be supported underneath the casing or by the optional pump stand which is not bolted to the foundation. In these cases, the pump is free to move with the piping in all directions except for vertically downward. The above mounting methods are recommended as they reduce the piping loads applied to the pump. In these cases, nozzle loads are limited only by the casing limitations. The pump may also be rigidly mounted, with the optional pump stand bolted to the foundation. In this case pump movement is restricted and piping loads are applied to both the pump and stand. In this case, nozzle loads are limited by both the casing and pump stand limitations. 4.6.4.2b Casing limitations To simplify or eliminate additional calculations, the In-Line casing may be treated as a spool of schedule 40 pipe with a diameter equal to the discharge, length equal to the face to face dimension (SD) and material equal to that of the casing. In cases where pump movement is limited, the constraint may be placed at the center of the spool. Stress in the pump flanges and bolting should not be ignored. This method Page 28 of 68 Discharge flange Moments Nm (lbf•ft) Mxs Mys Mzs 2 034 1 627 -3 390 (1 500) (1 200) (-2 500) 2 034 1 763 -4 746 (1 500) (1 300) (-3 500) 2 034 5 560 -5 424 (1 500) (4 100) (-4 000) Forces N (lbf) Fxd Fyd Fzd 3 558 8 896 -13 344 (800) (2 000) (-3 000) 6 227 11 120 -14 456 (1 400) (2 500) (-3 250) 6 672 17 792 -15 568 (1 500) (4 000) (-3 500) Moments Nm (lbf•ft) Mxd Myd Mzd -2 034 1 356 -3 390 (-1 500) (1 000) (-2 500) -2 034 2 915 -4 746 (-1 500) (2 150) (-3 500) -2 034 6 780 -5 424 (-1 500) (5 000) (-4 000) allows for the use of automated piping programs to determine the acceptability of loads. The casing limitations can also be determined by ANSI/HI 9.6.2. All information necessary to complete the evaluation is given below. For complete details please review the standard. a) Determine the appropriate casing “Nozzle load material group” from figure 3-2. b) Find the “Casing material correction factor” in figure 4-11 based upon the “Nozzle load material group” and operating temperature. Interpolation may be used to determine the correction factor for a specific temperature. c) Multiply the allowable loads found in figure 4-20 by the material correction factor. Record the adjusted loads. d) Calculate the applied piping loads at the center of the casing flanges according to the coordinate system found in figure 4-19. The 12 forces and moments possible are Fxs, Fys, Fzs, Mxs, Mys, Mzs, Fxd, Fyd, Fzd, Mxd, Myd and Mzd. For example, Fxd designates force in the “x” direction on the discharge flange. Mys designates the moment about the “y”-axis on the suction flange. e) The absolute value of the applied suction load divided by the corresponding adjusted load must be less than or equal to one. Also, the absolute value of the applied discharge load divided by the corresponding adjusted load must be less than or equal to one. For example: Fyd Fxs M zd ≤ 1.0, ≤ 1.0.......... .......... ..... ≤ 1.0, Fx _ adj Fy _ adj M z _ adj flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Figure 4-19 4.6.4.2c Pump stand limitations In cases where the pump is rigidly mounted by the pump stand, both the casing limitations and the pump stand limitations must be satisfied. Due to the limited load capacity of the pump stands, it may be necessary to restrain the piping to prevent loads. a) Ensure all applied loads are within the allowable limits of the casing. b) Translate the flange loads using the formulae found in figure 4-21. Dimensional variables SRS, SRD and RS can be found in figure 4-20. c) Calculate FT and FN using the formulae found in figure 4-21. d) FT and FN must be less than FTMAX and FNMAX found in figure 4-22. e) FT and FN must meet the combination formulae found in figure 4-22. Figure 4-20: Dimensional data and casing limitations Dimensions m (ft) 2x1.5V-6 2x1.5V-8 3x2V-7 3x1.5V-8 2x1.5V-10A 3x2V-10 4x3V-10 3x1.5V-13 3x2V-13 4x3V-13 6x4V-13 SD 0.381 (1.25) 0.432 (1.42) 0.432 (1.42) 0.483 (1.58) 0.483 (1.58) 0.508 (1.67) 0.635 (2.08) 0.61 (2.00) 0.61 (2.00) 0.711 (2.33) 0.762 (2.50) SRd 0.191 (0.625) 0.229 (0.75) 0.203 (0.67) 0.226 (0.74) 0.229 (0.75) 0.241 (0.79) 0.292 (0.96) 0.292 (0.96) 0.292 (0.96) 0.33 (1.08) 0.356 (1.17) SRs 0.191 (0.625) 0.203 (0.67) 0.229 (0.75) 0.254 (0.83) 0.254 (0.83) 0.267 (0.88) 0.343 (1.13) 0.318 (1.04) 0.318 (1.04) 0.381 (1.25) 0.406 (1.33) Rs 0.163 (0.53) 0.163 (0.53) 0.163 (0.53) 0.163 (0.53) 0.197 (0.65) 0.197 (0.65) 0.197 (0.65) 0.248 (0.81) 0.248 (0.81) 0.248 (0.81) 0.248 (0.81) Fx 1 824 (410) 1 601 (360) 2 824 (635) 1 601 (360) 1 423 (320) 2 402 (540) 2 823 (638) 1 134 (255) 2 002 (450) 2 535 (570) 2 891 (650) Allowable casing loads (suction or discharge) Forces N (lbf) Moments Nm (lbf•ft) Fy Fz Mx My Mz 17 685 1 824 692 976 692 (3 976) (410) (510) (720) (510) 17 685 1 601 692 976 692 (3 976) (360) (510) (720) (510) 28 147 2 824 1 120 1 722 1 120 (6 328) (635) (900) (1 270) (900) 17 685 1 601 692 976 692 (3 976) (360) (510) (720) (510) 17 685 1 423 692 976 692 (3 976) (320) (510) (720) (510) 28 147 2 402 1 120 1 722 1 120 (6 328) (540) (900) (1 270) (900) 28 147 2 823 1 803 2 549 1 803 (6 328) (638) (1 330) (1 880) (1 330) 17 685 1 134 692 976 692 (3 976) (255) (510) (720) (510) 28 147 2 002 1 120 1 722 1 120 (6 328) (450) (900) (1 270) (900) 28 147 2 535 1 803 2 549 1 803 (6 328) (570) (1 330) (1 880) (1 330) 83 195 2 891 2 210 3 119 2 210 (18 704) (650) (1 630) (2 300) (1 630) Figure 4-21: Pump stand load translation formulae Forces FXC = FXS + FXD FYC = FYS + FYD FZC = FZS + FZD Moments MXC = MXS + MXD + (FZS × SRS) - (FZD × SRD) MYC = MYS + MYD MZC = MZS + MZD - (FXS × SRS) + (FXD × SRD) M FT = Fxc + 0.707 × zc Rs FN = Fzc + Page 29 of 68 2 M + Fyc + 0.707 × zc Rs 2 ≤ FTMax M xc + M yc ≤ FN _ MAX 0.707Rs flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Figure 4-22: Allowable stand loads GP1 pumps GP2 V-10 pumps GP2 V-13 pumps FT MAX in N (lbf) 8 020 (1 800) 8 129 (1 827) 6 792 (1 535) FN MAX in N (lbf) 108 531 (24 400) 120 115 (27 004) 140 461 (31 579) 4.6.5 Pump and shaft alignment check After connecting the piping, rotate the pump drive shaft clockwise (viewed from motor end) by hand several complete revolutions to be sure there is no binding and that all parts are free. Recheck shaft alignment (see section 4.5). If piping caused unit to be out of alignment, correct piping to relieve strain on the pump. 4.6.6 Auxiliary piping 4.6.6.1 Mechanical seal When the pump is intended to be equipped with a mechanical seal, it is Flowserve standard practice to install the mechanical seal in the pump prior to shipment. Specific order requirements may specify that the seal be shipped separately, or none be supplied. It is the pump installer’s responsibility to determine if a seal was installed. If a seal was supplied but not installed, the seal and installation instructions will be shipped with the pump. Failure to ensure that a seal is installed may result in serious leakage of the pumped fluid. Seal and seal support system must be installed and operational as specified by the seal manufacturer. The stuffing box/seal chamber/gland may have ports that have been temporarily plugged at the factory to keep out foreign matter. It is the installer’s responsibility to determine if these plugs should be removed and external piping connected. Refer to the seal drawings and or the local Flowserve representative for the proper connections. 4.6.6.2 Packing When the pump is intended to be equipped with shaft packing, it is not Flowserve standard practice to install the packing in the stuffing box prior to shipment. The packing is shipped with the pump. It is the pump installer’s responsibility to install the packing in the stuffing box. Combination loading in N (lbf) FN + (13.556) FT !#"%$&(')" FN + (13.556) FT !+*,(,-$$ FN + (0.0019) FT2 - (0.941) FT !#"*$.""%' FN + (0.0086) FT2 - (0.941) FT !+*/($$, FN + (0.0018) FT2 + (8.453) FT !0"1,-$2,3" FN + (0.0079) FT2 + (8.453) FT !+)"'/4 4.6.6.3 Piping connection – seal/packing support system If the pump has a seal support system it is mandatory that this system be fully installed and operational before the pump is started. If packing is used: 4.6.6.3a Packing lubrication Water, when compatible with the pumpage, should be introduced into tap V (figure 4-23) at pressure 69 to 103 kPa (10 to 15 lbf/in.2) above the stuffing box pressure. The gland should be adjusted to give a flow rate of 20 to 30 drops per minute for clean fluid. For abrasive applications, the regulated flow rate should be 0.06 to 0.13 l/s (1 to 2 US gpm). Figure 4-23 Grease lubrication, when compatible with the liquid being pumped, may be used. Again, introduced into tap V. In non-abrasive applications the liquid being pumped may be sufficient to lubricate the packing without need for external lines. Tap V should be plugged. 4.6.6.3b Abrasive packing arrangement The installation procedures are the same as the standard packing with some exceptions. A special lip seal is installed first, followed by two seal cage assemblies, then two of the packing rings provided (figure 4-24). A flush line from a clean external source should be connected via tap V, in the top of the stuffing box. Failure to ensure that the packing is installed may result in serious leakage of the pumped fluid. Figure 4-24 Page 30 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 4.6.6.4 Piping connection - bearing housing cooling system Make connections as shown below. Liquid at less than 32 °C (90 °F) should be supplied at a regulated flow rate of at least 0.06 l/s (1 US gpm). Notes: 1. When circulating steam, use top hole for inlet. Both bottom holes must be plumbed together for outlet, to ensure draining both sides of jacket. 2. When circulating liquid use both bottom holes as inlets. Use top hole as outlet. 4.6.6.7 Piping connection - Oil mist lubrication system The piping connections for an oil mist lubrication system are shown below. Figure 4-25 4.6.6.5 Piping connection - support leg cooling for centerline mounting option If the casing is centerline mounted, and the process temperature is over 178 °C (350 °F), then the casing support legs may need to be cooled. Cool water - less than 32 °C (90 °F) - should be run through the legs at a flow rate of at least 0.06 l/s (1 US gpm) as shown below. Figure 4-29 Figure 4-26 4.6.6.6 Piping connection - heating/cooling fluid for jacketed cover/casing The piping connections for jacketed covers and casings are shown below. The flow rate of the cooling water - less than 32 °C (90 °F) - should be at least 0.13 l/s (2 US gpm). Figure 4-30 4.7 Electrical connections Electrical connections must be made by a qualified Electrician in accordance with relevant local national and international regulations. It is important to be aware of the EUROPEAN DIRECTIVE on potentially explosive areas where compliance with IEC60079-14 is an additional requirement for making electrical connections. Figure 4-27 Figure 4-28 Page 31 of 68 It is important to be aware of the EUROPEAN DIRECTIVE on electromagnetic compatibility when wiring up and installing equipment on site. Attention must be paid to ensure that the techniques used during wiring/installation do not increase electromagnetic emissions or decrease the electromagnetic immunity of the equipment, wiring or any connected devices. If in any doubt contact Flowserve for advice. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 The motor must be wired up in accordance with the motor manufacturer’s instructions (normally supplied within the terminal box) including any temperature, earth leakage, current and other protective devices as appropriate. The identification nameplate should be checked to ensure the power supply is appropriate. See section 5.4, Direction of rotation, before connecting the motor to the electrical supply. For close coupled pumps it is necessary to wire the motor with flexible conduit of sufficient length to allow the motor/power end assembly to be moved back from the casing for maintenance. 4.8 Final shaft alignment check 4.8.1 Horizontal pumps a) Level baseplate if appropriate. b) Mount and level pump if appropriate. Level the pump by putting a level on the discharge flange. If not level, adjust the footpiece as follows: Mark 3A and ANSI 3 design Add or delete shims [3126.1] between the footpiece and the bearing housing. Mark 3 design Use the adjuster nut [6576] to adjust the footpiece up or down. c) Check initial alignment. If pump and driver have been remounted or the specifications given below are not met, perform an initial alignment as described in section 4.5. This ensures there will be sufficient clearance between the motor hold down bolts and motor foot holes to move the motor into final alignment. The pump and driver should be within 0.38 mm (0.015 in.) FIM (full indicator movement) parallel, and 0.0025 mm/mm (0.0025 in./in.) FIM angular. Stilt mounted baseplates If initial alignment cannot be achieved with the motor fasteners centered, the baseplate may be twisted. Slightly adjust (one turn of the adjusting nut) the stilts at the driver end of the baseplate and check for alignment to the above tolerances. Repeat as necessary while maintaining a level condition as measured from the pump discharge flange. d) Run piping to the suction and discharge to the pump. There should be no piping loads transmitted to the pump after connection is made. Recheck the alignment to verify that there are no significant changes. e) Perform final alignment. Check for soft-foot under the driver. An indicator placed on the coupling, reading in the vertical direction, should not indicate Page 32 of 68 more than 0.05 mm (0.002 in.) movement when any driver fastener is loosened. Align the driver first in the vertical direction by shimming underneath its feet. f) When satisfactory alignment is obtained the number of shims in the pack should be minimized. It is recommended that no more than five shims be used under any foot. Final horizontal alignment is made by moving the driver. Maximum pump reliability is obtained by having near perfect alignment. Flowserve recommends no more than 0.05 mm (0.002 in.) parallel, and 0.0005 mm/mm (0.0005 in./in.) angular misalignment. (See section 6.8.4.7.) g) Operate the pump for at least an hour or until it reaches final operating temperature. Shut the pump down and recheck alignment while the pump is hot. Piping thermal expansion may change the alignment. Realign pump as necessary. 4.8.2 Close coupled pumps Alignment between the pump shaft and motor shaft is built in by precise machining of the parts that position these shafts. Parallel alignment of 0.018 mm (0.007 in.) and angular alignment of 0.002 mm/mm (0.002 in/in) can be expected. If a more refined alignment is desired, it can be accomplished with the “C-Plus” optional alignment feature. The C-Plus option requires that a spacer as shown in section 8.9 be installed. Four adjusting screws are used to push on the motor mounting studs to achieve parallel alignment. The motor mounting fasteners must be snug, but not tight during alignment. It may be necessary to check the motor alignment with motor fasteners tight. Corrections may be made until the desired alignment is achieved. The motor fasteners, adjusters and jam nuts should be tight. 4.8.3 In-Line pumps The final field alignment follows the same procedure as the initial alignment as described in section 4.5.2. Maximum pump reliability is obtained by having near perfect alignment. Flowserve recommends no more than 0.05 mm (0.002 in.) parallel, and 0.0005 mm/mm (0.0005 in./in.) angular misalignment. 4.9 Protection systems The following protection systems are recommended particularly if the pump is installed in a potentially explosive area or is handling a hazardous liquid. If in doubt consult Flowserve. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 If there is any possibility of the system allowing the pump to run against a closed valve or below minimum continuous safe flow a protection device should be installed to ensure the temperature of the liquid does not rise to an unsafe level. If there are any circumstances in which the system can allow the pump to run dry, or start up empty, a power monitor should be fitted to stop the pump or prevent it from being started. This is particularly relevant if the pump is handling a flammable liquid. If leakage of product from the pump or its associated sealing system can cause a hazard it is recommended that an appropriate leakage detection system is installed. To prevent excessive surface temperatures at bearings it is recommended that temperature or vibration monitoring is carried out. 5 COMMISSIONING, STARTUP, OPERATION AND SHUTDOWN These operations must be carried out by fully qualified personnel. 5.1 Pre-commissioning procedure 5.1.1 Pre start-up checks Prior to starting the pump it is essential that the following checks be made. These checks are all described in detail in the Maintenance section of this manual. • Pump and motor properly secured to the baseplate • Remove the temporary motor supports installed for shipping close coupled pumps • All fasteners tightened to the correct torque • Coupling guard in place and not rubbing • Rotation check, see section 5.4. This is absolutely essential • Impeller clearance setting • Shaft seal properly installed • Seal support system operational • Bearing lubrication • Bearing housing cooling system operational • Support leg cooling for centerline mounting option operational • Heating/cooling for jacketed casing/cover operational • Pump instrumentation is operational • Pump is primed • Rotation of shaft by hand As a final step in preparation for operation, it is important to rotate the shaft by hand to be certain that all rotating parts move freely, and that there are no foreign objects in the pump casing. 5.2 Pump lubricants 5.2.1 Oil bath Oil bath is available on all product lines with the exception of the In-Line pump. The standard bearing housing bearings are oil bath lubricated and are not lubricated by Flowserve. Before operating the pump, fill the bearing housing to the center of the oil sight glass with the proper type oil. (See figure 5-2 for approximate amount of oil required - do not overfill.) On the Mark 3A design, an optional oil slinger is available. The oil slinger is not necessary; however, if used, it provides an advantage by allowing a larger tolerance in acceptable oil level. Without an oil slinger, the oil level in the bearing housing must be 1 maintained at ±3 mm (± /8 in.) from the center of the sight glass. The sight glass has a 6 mm (¼ in.) hole in the center of its reflector. The bearing housing oil level must be within the circumference of the center hole to ensure adequate lubrication of the bearings. See figure 5-3 for recommended lubricants. DO NOT USE DETERGENT OILS. The oil must be free of water, sediment, resin, soaps, acid and fillers of any kind. It should contain rust and oxidation inhibitors. The proper oil viscosity is determined by the bearing housing operating temperature as given in figure 5-4. To add oil to the housing, clean and then remove the vent plug [6521] at the top of the bearing housing, pour in oil until it is visually half way up in the sight glass [3856]. Fill the constant level oiler bottle, if used, and return it to its position. The correct oil level is obtained with the constant level oiler in its lowest position, which results in the oil level being at the top of the oil inlet pipe nipple, or half way up in the sight glass window. Oil must be visible in the bottle at all times. Note that on ANSI 3A™ power ends there is no constant level oiler. As stated above, proper oil level is the center of the “bull’s eye” sight glass [3856]. (See figure 5-1.) Figure 5-1 Page 33 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 In many pumping applications lubricating oil becomes contaminated before it loses its lubricating qualities or breaks down. For this reason it is recommended that the first oil change take place after approximately 160 hours of operation, at which time, the used oil should be examined carefully for contaminants. During the initial operating period monitor the bearing housing operating temperature. Record the external bearing housing temperature. See figure 5-5 for maximum acceptable temperatures. The normal oil change interval is based on temperature and is shown in figure 5-6. Figure 5-2: Amount of oil required Pump Group 1 Group 2 Group 3 Mark 3 148 ml (5 fl. oz.) 560 ml (19 fl. oz.) 1419 ml (48 fl. oz.) Mark 3A 251 ml (8.5 fl. oz.) 946 ml (32 fl. oz.) 1419 ml (48 fl. oz.) The maximum temperature that the bearing can be exposed to is 105 °C (220 °F). Centrifugal pump lubrication Figure 5-3a: Recommended oil lubricants Oil Splash / force feed / oil mist lubrication Viscosity cSt at 40 ºC Oil temp. range * ºC (ºF) Designation according to DIN51502 ISO VG 32 46 68 -5 to 65 (-23 to 149) -5 to 78 (-23 to 172) -5 to 80 (-23 to 176) HL/HLP 32 HL/HLP 46 HL/HLP 68 BP Energol HL32 BP Energol HL46 BP Energol HL68 BP Energol HLP32 BP Energol HLP46 BP Energol HLP68 Anstron HL32 Anstron HL46 Anstron HL68 DEA Anstron HLP32 Anstron HLP46 Anstron HLP68 OLNA 32 HYDRELEF 32 TURBELF SA46 TURBELF SA68 Elf TURBELF 32 ELFOLNA DS32 ELFOLNA DS46 ELFOLNA DS68 TERESSO 32 TERESSO 46 TERESSO 68 Esso NUTO H32 NUTO H46 NUTO H68 Mobil DTE oil light Mobil DTE oil medium Mobil DTE oil heavy medium Mobil Mobil DTE13M Mobil DTE15M Mobil DTE26 MobilDTE24 Mobil DTE25 Q8 Verdi 32 Q8 Verdi 46 Q8 Verdi 68 Q8 Q8 Haydn 32 Q8 Haydn 46 Q8 Haydn 68 Shell Tellus 32 Shell Tellus 01 C 46 Shell Tellus 01 C 68 Shell Shell Tellus 37 Shell Tellus 01 46 Shell Tellus 01 68 Rando Oil HD 32 Rando Oil 46 Rando Oil 68 Texaco Rando Oil HD-AZ-32 Rando Oil HD B-46 Rando Oil HD C-68 Wintershall Wiolan HN32 Wiolan HN46 Wiolan HN68 (BASF Group) Wiolan HS32 Wiolan HS46 Wiolan HS68 * Note that some oils have a greater Viscosity Index than the minimum acceptable of 95 (eg Mobil DTE13M) which may extend the minimum temperature capability of the oil. Always check the grade capability where the ambient is less than -5 ºC (-23 ºF). Oil companies and lubricants BP Figure 5-3b: Recommended lubricants Mineral oil Synthetic Grease Quality mineral oil with rust and oxidation inhibitors. Mobil DTE heavy/medium (or equivalent) Royal Purple or Conoco SYNCON (or equivalent). Some synthetic lubricants require Viton O-rings. EXXON POLYREX EM (or compatible) – horizontal Polyurea with mineral oil EXXON Unirex N3 (or compatible) – In-Line Lithium Complex with mineral oil Figure 5-4: Oil viscosity grades Maximum oil temperature Up to 71 °C (160 °F) 71-80 °C (160-175 °F) 80-94 °C (175-200 °F) Page 34 of 68 ISO viscosity grade 46 68 100 Minimum viscosity index 95 95 95 Figure 5-5: Maximum external housing temperatures Lubrication Oil bath Oil mist Grease Temperature 82 °C (180 °F) 82 °C (180 °F) 94 °C (200 °F) Figure 5-6: Lubrication intervals * Under 71 °C 71-80 °C 80-94 °C (160 °F) (160-175 °F) (175-200 °F) Grease 6 months 3 months 1.5 months Mineral oil 6 months 3 months 1.5 months Synthetic oil** 18 months 18 months 18 months * Assuming good maintenance and operation practices, and no contamination. ** May be increased to 36 months with ANSI 3A™ power end. *** Bearing temperatures up to 16 °C (30 °F) higher than housing. Lubricant flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 5.2.2 Grease Figure 5-9: Regreasable configuration 5.2.2.1 Regreasable Single shielded regreasable bearings When the grease lubrication option is specified, single shielded bearings, grease fittings and vent pipe plugs are installed inboard and outboard. The orientation of the bearing shields is different for horizontal pumps (Standard, Sealmatic, Unitized, Recessed, and Lo-Flo - see figure 5-7) and In-Line pumps (see figure 5-8). Figure 5-7: Horizontal pump shield orientation Figure 5-10: Horizontal lubrication amounts Housing Figure 5-8: In-Line pump shield orientation Group 1 inboard Group 1 outboard Group 1 duplex Group 2 inboard Group 2 outboard Group 2 duplex Horizontal pump bearings are packed with Exxon POLYREX EM grease prior to assembly. For relubrication, a grease with the same type base (polyurea) and oil (mineral) should be used. In the case of the In-Line pump the bearings are packed with Exxon Unirex N3 grease. For relubrication, a grease with the same type base (lithium) and oil (mineral) should be used. To regrease, remove the pipe plug from both the inboard and outboard bearing location. (See figure 5-9.) After relubricating the bearings three times, it is typically recommended that the bearing housing is cleaned out. To regrease bearings under coupling guard, stop pump, lock the motor, remove coupling guard, and then regrease the bearings. The amount of grease required for horizontal pumps is shown in figure 5-10 and for In-Line pumps in figure 5-11. Group 3 inboard Group 3 outboard Group 3 duplex Initial lube Relubrication Until grease comes out of plug Until grease comes out of plug 34 cm3 (2.1 in.3) Until grease comes out of plug Until grease comes out of plug 68 cm3 (4.1 in.3) Until grease comes out of plug Until grease comes out of plug 115 cm3 (7.0 in.3) 7.5 cm3 (0.46 in.3) 14 cm3 (0.85 in.3) 17 cm3 (1.0 in.3) 17 cm3 (1.0 in.3) 28 cm3 (1.7 in.3) 34 cm3 (2.1 in.3) 30 cm3 (1.8 in.3) 54 cm3 (3.3 in.3) 60 cm3 (3.7 in.3) Figure 5-11: In-Line lubrication amounts Housing location New bearing Relubrication Group 1 inboard 10 cm3 (0.6 in.3) 7.5 cm3 (0.46 in.3) 3 3 Group 1 outboard 20.5 cm (1.3 in. ) 14 cm3 (0.85 in.3) 3 3 Group 2 inboard 16.4 cm (1.0 in. ) 17 cm3 (1.0 in.3) 3 3 Group 2 outboard 47.4 cm (2.9 in. ) 28 cm3 (1.7 in.3) *If new bearings are not lubricated, they should be packed prior to installation and the housing lubricated as described above. Do not fill the housing with oil when greased bearings are used. The oil will leach the grease out of the bearings and the life of the bearings may be drastically reduced. 5.2.2.1 Grease for life Double shielded or double sealed bearings These bearings are packed with grease by the bearing manufacturer and should not be relubricated. The replacement interval for these bearings is greatly affected by their operating temperature and speed. Shielded bearings typically operate cooler. Page 35 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 5.2.3 Oil mist The inlet port for all horizontal pumps is the plugged ½ in. NPT located at the top of the bearing housing. A vent fitting has been supplied on the bearing carrier as well as a plugged ¼ in. NPT bottom drain on the bearing housing. See section 4.6.6.7, Oil mist lubrication system. Do not allow oil level to remain above the center of the bearing housing sight glass window with purge mist (wet sump) systems. A direction arrow is cast on the front of the casing as shown in figure 5-13. Make sure the motor rotates in the same direction. The optional oil slinger must not be used with an oil mist system. There are two inlet ports for In-Line pumps. In addition to the connection described above a second inlet is made at the LQ137SOXJJHGSRUWRQWKHEHDULQJ carrier [3240]. A vent fitting has been supplied on the bearing carrier as well as a plugged LQ137ERWWRP drain on the bearing housing for Group 1 pumps and on the adapter [1340] for Group 2 pumps. 5.3 Impeller clearance The impeller clearance was set at the factory based on the application temperature at the time the pump was purchased. (See figure 5-12.) For a reverse vane impeller the clearance is set to the cover while the open impeller clearance is set to the casing. If the process temperature changes the impeller clearance must be reset. (See section 6.6.) Figure 5-13 5.4.2 Coupling installation The coupling (figure 5-14) should be installed as advised by the coupling manufacturer. Pumps are shipped without the spacer installed. If the spacer has been installed to facilitate alignment, then it must be removed prior to checking rotation. Remove all protective material from the coupling and shaft before installing the coupling. Figure 5-12: Impeller clearance settings Temperature °C (°F) Clearance mm (in.) < 93 (200) 0.46 ± 0.08 (0.018 ± 0.003) 93 to 121 (200 to 250) 0.53 (0.021) 122 to 149 (251 to 300) 0.61 (0.024) 150 to 176 (301 to 350) 0.69 (0.027) 177 to 204 (351 to 400) 0.76 (0.030) 205 to 232 (401 to 450) 0.84 (0.033) >232 (450) 0.91 (0.036) Notes: 1. For 3x1.5-13 and 3x2-13 at 3500 rpm add 0.08 mm (0.003 in.). 2. Rotation of bearing carrier from center of one lug to center of next results in axial shaft movement of 0.1 mm (0.004 in.). 3. Reverse vane impeller set to cover, open impeller to casing. 5.4 Direction of rotation 5.4.1 Rotation check It is absolutely essential that the rotation of the motor be checked before connecting the shaft coupling. Incorrect rotation of the pump, for even a short time, can dislodge and damage the impeller, casing, shaft and shaft seal. All Mark 3 pumps turn clockwise as viewed from the motor end. Page 36 of 68 Figure 5-14 5.5 Guarding Power must never be applied to the driver when the coupling guard is not installed. Flowserve coupling guards are safety devices intended to protect workers from inherent dangers of the rotating pump shaft, motor shaft and coupling. It is intended to prevent entry of hands, fingers or other body parts into a point of hazard by reaching through, over, under or around the guard. No standard coupling guard provides complete protection from a disintegrating coupling. Flowserve cannot guarantee their guards will completely contain an exploding coupling. 5.5.1 Clam shell guard - standard The standard coupling guard for all Mark 3 pumps is the “clam shell” design and is shown in figure 5-15. It is hinged at the top and it can be removed by loosening one of the foot bolts and sliding the support leg out from under the cap screw. Note that the foot is slotted. The leg can then be rotated upward and half of the guard can be disengaged (unhinged) from the other. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Only one side of the guard needs to be removed. To reassemble simply reverse the above procedure. d) e) If motor diameter is smaller than guard diameter, trim guard so that it extends over the end of the motor as far as possible. Deburr the trimmed end with a file or a sharp knife if ClearGuard™. Care must be taken to eliminate all sharp edges. Reference center Trim this end Figure 5-15 The coupling guard shown in figure 5-15 conforms to the USA standard ASME B15.1, “Safety standard for mechanical power transmission apparatus.” Flowserve manufacturing facilities worldwide conform to local coupling guard regulations. 5.5.2 ClearGuard™ - optional Flowserve offers as an option a ClearGuard™, which allows you to see the condition of the coupling (see figure 5-16). This guard can be used in place of the existing clamshell guard described above. Disassembly of the ClearGuard™ is accomplished by removing the fasteners that hold the two guard halves together followed by removing the foot bolts and rotating the support leg out of the slot on the guard. Figure 5-16 5.5.3 Trimming instructions In order to correctly fit the pump/motor configuration, each guard must be trimmed to a specific length. This trimming is done on the motor end of the guard. a) Measure minimum distance from the center of mounting hole in the baseplate to the motor. (If clam shell guard proceed to step c.) b) Locate a reference center in the slot of the ClearGuard™ coupling guard flange, see figure 5-17. Transfer the length measurement to the guard using this reference center. c) Trim the motor end of the guard according to the above measurement. Trimming is best done with a band saw, but most other types of manual or power saws give acceptable results. Care must be taken to ensure that there is no gap larger than 6 mm (0.24 in.) between the motor and the coupling guard. Page 37 of 68 Measurement step a) Figure 5-17 5.5.4 Assembly instructions Clam shell guard a) Mount support leg to each clam shell, figure 5-15. b) Attach one half of the guard to the baseplate. c) Engage the tabs of guard halves together. d) Attach the second support leg to the baseplate. ClearGuard™ a) Place the bottom and top halves of the guard around the coupling. b) Install the support legs by inserting and then rotating the tab on the leg through the slot in the guard until it comes through and locks the top and bottom halves of the guard together. c) Attach the support legs to the baseplate using the fasteners and washers provided. d) Install fasteners in the holes provided to secure the guard flanges together. 5.6 Priming and auxiliary supplies The Mark 3 standard, Sealmatic, Recessed Impeller, Lo-Flo, and In-Line centrifugal pump will not move liquid unless the pump is primed. A pump is said to be “primed” when the casing and the suction piping are completely filled with liquid. Open discharge valves a slight amount. This will allow any entrapped air to escape and will normally allow the pump to prime, if the suction source is above the pump. When a condition exists where the suction pressure may drop below the pump’s capability, it is advisable to add a low-pressure control device to shut the pump down when the pressure drops below a predetermined minimum. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 The Mark 3 Unitized self-priming centrifugal pumps have a slightly different requirement regarding priming. The initial priming liquid must be added to the pump casing until the liquid has reached the bottom of the suction nozzle. Once the initial prime is in place, the pump will automatically replenish itself and additional priming liquids are not normally needed. If liquid is lost, additional priming liquid may be needed. 5.7 Starting the pump a) Open the suction valve to full open position. It is very important to leave the suction valve open while the pump is operating. Any throttling or adjusting of flow must be done through the discharge valve. Partially closing the suction valve can create serious NPSH and pump performance problems. b) Never operate pump with both the suction and discharge valves closed. This could cause an explosion. c) Ensure the pump is primed. (See section 5.6.) d) All cooling, heating, and flush lines must be started and regulated. e) Start the driver (typically, the electric motor). f) Slowly open the discharge valve until the desired flow is reached, keeping in mind the minimum continuous flow listed in section 3.4. g) It is important that the discharge valve be opened within a short interval after starting the driver. Failure to do this could cause a dangerous build up of heat, and possibly an explosion. 5.8 Running or operation 5.8.1 Minimum continuous flow Minimum continuous stable flow is the lowest flow at which the pump can operate and still meet the bearing life, shaft deflection and bearing housing vibration limits documented in the latest version of ASME B73.1M. Pumps may be operated at lower flows, but it must be recognized that the pump may exceed one or more of these limits. For example, vibration may exceed the limit set by the ASME standard. The size of the pump, the energy absorbed, and the liquid pumped are some of the considerations in determining the minimum continuous flow (MCF). The minimum continuous flow (capacity) is established as a percentage of the best efficiency point (BEP). (See section 3.4.4.) Page 38 of 68 5.8.2 Minimum thermal flow All Mark 3 pumps also have a minimum thermal flow. This is defined as the minimum flow that will not cause an excessive temperature rise. Minimum thermal flow is application dependent. Do not operate the pump below minimum thermal flow, as this could cause an excessive temperature rise. Contact a Flowserve sales engineer for determination of minimum thermal flow. Avoid running a centrifugal pump at drastically reduced capacities or with discharge valve closed for extended periods of time. This can cause severe temperature rise and the liquid in the pump may reach its boiling point. If this occurs, the mechanical seal will be exposed to vapor, with no lubrication, and may score or seize to the stationary parts. Continued running under these conditions when the suction valve is also closed can create an explosive condition due to the confined vapor at high pressure and temperature. Thermostats may be used to safeguard against over heating by shutting down the pump at a predetermined temperature. Safeguards should also be taken against possible operation with a closed discharge valve, such as installing a bypass back to the suction source. The size of the bypass line and the required bypass flow rate is a function of the input horsepower and the allowable temperature rise. 5.8.3 Reduced head Note that when discharge head drops, the pump’s flow rate usually increases rapidly. Check motor for temperature rise as this may cause overload. If overloading occurs, throttle the discharge. 5.8.4 Surging condition A rapidly closing discharge valve can cause a damaging pressure surge. A dampening arrangement should be provided in the piping. 5.8.5 Operation in sub-freezing conditions When using the pump in sub-freezing conditions where the pump is periodically idle, the pump should be properly drained or protected with thermal devices which will keep the liquid in the pump from freezing. High chrome iron pumps are not recommended for applications below -18 °C (0 °F). flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 5.9 Stopping and shutdown 5.9.1 Shutdown considerations When the pump is being shutdown, the procedure should be the reverse of the start-up procedure. First, slowly close the discharge valve, shut down the driver, and then close the suction valve. Remember that closing the suction valve while the pump is running is a safety hazard and could seriously damage the pump and other equipment. 5.9.2 Shutdown - Mark 3 Self-Priming At shutdown, the liquid in the discharge piping falls back into the priming chamber and washes through the impeller into the suction. The backflow creates a siphon effect in the casing until the liquid level falls below the bottom of the suction nozzle. The inertia of the flow pulls fluid from the priming chamber to a level lower than the initial priming fill. Though the level is lower, there is still sufficient fluid in the priming chamber to allow the pump to reprime itself. 5.10 Hydraulic, mechanical and electrical duty 5.10.1 Net positive suction head (NPSH) Net positive suction head - available (NPSHA) is the measure of the energy in a liquid above the vapor pressure. It is used to determine the likelihood that a fluid will vaporize in the pump. It is critical because a centrifugal pump is designed to pump a liquid, not a vapor. Vaporization in a pump will result in damage to the pump, deterioration of the Total differential head (TDH), and possibly a complete stopping of pumping. Net positive suction head - required (NPSHR) is the decrease of fluid energy between the inlet of the pump, and the point of lowest pressure in the pump. This decrease occurs because of friction losses and fluid accelerations in the inlet region of the pump and particularly accelerations as the fluid enters the impeller vanes. The value for NPSHR for the specific pump purchased is given in the pump data sheet, and on the pump performance curve. For a pump to operate properly the NPSHA must be greater than the NPSHR. Good practice dictates that this margin should be at least 1.5 m (5 ft) or 20%, whichever is greater. Ensuring that NPSHA is larger than NPSHR by the suggested margin will greatly enhance pump performance and reliability. It will also reduce the likelihood of cavitation, which can severely damage the pump. Page 39 of 68 5.10.2 Specific gravity (SG) Pump capacity and total head in meters (feet) of liquid do not change with SG, however pressure displayed on a pressure gauge is directly proportional to SG. Power absorbed is also directly proportional to SG. It is therefore important to check that any change in SG will not overload the pump driver or overpressurize the pump. 5.10.3 Viscosity For a given flow rate the total head reduces with increased viscosity and increases with reduced viscosity. Also for a given flow rate the power absorbed increases with the increased viscosity, and reduces with reduced viscosity. It is important that checks are made with your nearest Flowserve office if changes in viscosity are planned. 5.10.4 Pump speed Changing the pump speed affects flow, total head, power absorbed, NPSHR, noise and vibration levels. Flow varies in direct proportion to pump speed. Head varies as speed ratio squared. Power varies as speed ratio cubed. If increasing speed it is important to ensure the maximum pump working pressure is not exceeded, the driver is not overloaded, NPSHA > NPSHR and that noise and vibration are within local requirements and regulations. 6 MAINTENANCE It is the plant operator’s responsibility to ensure that all maintenance, inspection and assembly work is carried out by authorized and qualified personnel who have adequately familiarized themselves with the subject matter by studying this manual in detail. (See also section 1.6.2.) Any work on the machine must be performed when it is at a standstill. It is imperative that the procedure for shutting down the machine is followed, as described in section 5.9. On completion of work all guards and safety devices must be re-installed and made operative again. Before restarting the machine, the relevant instructions listed in section 5, Commissioning, start up, operation and shut down must be observed. Oil and grease leaks may make the ground slippery. Machine maintenance must always begin and finish by cleaning the ground and the exterior of the machine. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 If platforms, stairs and guard rails are required for maintenance, they must be placed for easy access to areas where maintenance and inspection are to be carried out. The positioning of these accessories must not limit access or hinder the lifting of the part to be serviced. When air or compressed inert gas is used in the maintenance process, the operator and anyone in the vicinity must be careful and have the appropriate protection. Do not spray air or compressed inert gas on skin. Do not direct an air or gas jet towards other people. Never use air or compressed inert gas to clean clothes. Before working on the pump, take measures to prevent the pump from being accidentally started. Place a warning sign on the starting device: "Machine under repair: do not start." With electric drive equipment, lock the main switch open and withdraw any fuses. Put a warning sign on the fuse box or main switch: "Machine under repair: do not connect." Never clean equipment with flammable solvents or carbon tetrachloride. Protect yourself against toxic fumes when using cleaning agents. Refer to the parts list shown in section 8 for item number references used throughout this section. 6.1 Maintenance schedule It is recommended that a maintenance plan and schedule be implemented, in accordance with these User Instructions, to include the following: a) Any auxiliary systems installed must be monitored, if necessary, to ensure they function correctly. b) Gland packing must be adjusted correctly to give visible leakage and concentric alignment of the gland follower to prevent excessive temperature of the packing or follower. c) Check for any leaks from gaskets and seals. The correct functioning of the shaft seal must be checked regularly. d) Check bearing lubricant level, and the remaining hours before a lubricant change is required. e) Check that the duty condition is in the safe operating range for the pump. Page 40 of 68 f) Check vibration, noise level and surface temperature at the bearings to confirm satisfactory operation. g) Check dirt and dust is removed from areas around close clearances, bearing housings and motors. h) Check coupling alignment and re-align if necessary 6.1.1 Preventive maintenance The following sections of this manual give instructions on how to perform a complete maintenance overhaul. However, it is also important to periodically repeat the Pre start-up checks listed in section 5.1. These checks will help extend pump life as well as the length of time between major overhauls. 6.1.2 Need for maintenance records A procedure for keeping accurate maintenance records is a critical part of any program to improve pump reliability. There are many variables that can contribute to pump failures. Often long term and repetitive problems can only be solved by analyzing these variables through pump maintenance records. 6.1.3 Cleanliness One of the major causes of pump failure is the presence of contaminants in the bearing housing. This contamination can be in the form of moisture, dust, dirt and other solid particles such as metal chips. Contamination can also be harmful to the mechanical seal (especially the seal faces) as well as other parts of the pump. For example, dirt in the impeller threads could cause the impeller to not be seated properly against the shaft. This, in turn, could cause a series of other problems. For these reasons, it is very important that proper cleanliness be maintained. Some guidelines are listed below. • After draining the oil from the bearing housing, periodically send it out for analysis. If it is contaminated, determine the cause and correct • The work area should be clean and free from dust, dirt, oil, grease etc • Hands and gloves should be clean • Only clean towels, rags and tools should be used 6.2 Spare parts The decision on what spare parts to stock varies greatly depending on many factors such as the criticality of the application, the time required to buy and receive new spares, the erosive/corrosive nature of the application, and the cost of the spare part. Section 8 identifies all of the components that make up each pump addressed in this manual. Please refer to the Flowserve Mark 3 Pump Parts Catalog for more information. A copy of this book can be obtained from your local Flowserve sales engineer or distributor/representative. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Prior to resizing impellers in high chrome iron and nickel, please consult your local Flowserve sales representative. 6.2.1 Ordering of spare parts Flowserve keeps records of all pumps that have been supplied. Spare parts can be ordered from your local Flowserve sales engineer or from a Flowserve distributor or representative. When ordering spare parts the following information should be supplied: 1) Pump serial number 2) Pump size and type 3) Part name – see section 8 4) Part item number – see section 8 5) Material of construction (alloy) 6) Number of parts required The pump size and serial number can be found on the nameplate located on the bearing housing. (See figure 3-1.) 6.3 Recommended spares and consumable items Standard hand tools SAE • Hand wrenches • Socket wrenches • Allen wrenches • Soft mallet • Screwdrivers Specialized equipment • Bearing pullers • Bearing induction heaters • Dial indicators • Spanner wrench • Flowserve Mark 3 tool kit (see below) To simplify maintenance, it is recommended that the Flowserve Mark 3 tool kit (shown in figure 6-1) is used. This tool kit includes a handy impeller wrench, which simplifies installation and removal of the impeller. It also contains “nose cones” which protect shaft threads and O-rings during maintenance. This tool kit can be ordered from your local Flowserve sales engineer or from a Flowserve distributor or representative. Mechanical process fluid seals, bearing housing lip seals, bearings, shafting, impeller, and gaskets. 6.4 Tools required A typical range of tools that will be required to maintain these pumps is listed below. Figure 6-1 6.5 Fastener torques Figure 6-2: Recommended bolt torques Item Description Group 1 non-lubricated [6570.12] [6570.12] [6570.5] [6580.2] [6580.2] Bearing retainer cap screws - standard bearings n/a 3 Bearing retainer cap screws - duplex bearings /16 in. – 6 Nm (4 lbf•ft) Bearing housing/adapter cap screws and nuts n/a 5 67 – 16 Nm (12 lbf•ft) Mechanical seal gland studs/nuts, with gasket 5 67 – 27 Nm (20 lbf•ft) Mechanical seal gland studs/nuts, with O-ring [6580.1] Casing studs/nuts [6570.2] [6570.3] [6570.4] [6570.13] [6570.15] [3712] Notes: 1. 2. ½ in. – 41 Nm (30 lbf•ft) Group 2 non-lubricated n/a /16 in. – 6 Nm (4 lbf•ft) ½ in. – 54 Nm (40 lbf•ft) 5 67 – 16 Nm (12 lbf•ft) 5 67 – 27 Nm (20 lbf•ft) ½ in. – 41 Nm (30 lbf•ft) 5 67 – 81 Nm (60 lbf•ft) 5 67 – 27 Nm (20 lbf•ft) ½ in. – 41 Nm (30 lbf•ft) ¾ in. – 217 Nm (160 lbf•ft) 5 67 – 16 Nm (12 lbf•ft) ½ in. – 54 Nm (40 lbf•ft) 3 Group 3 non-lubricated 5 /16 in. – 16 Nm (12 lbf•ft) /16 in. –16 Nm (12 lbf•ft) 5 67 – 122 Nm (90 lbf•ft) ½ in. – 41 Nm (30 lbf•ft) ½ in. – 54 Nm (40 lbf•ft) ¾ in. – 136 Nm (100 lbf•ft) 5 67 – 217 Nm (160 lbf•ft) ½ in. – 54 Nm (40 lbf•ft) ½ in. – 41 Nm (30 lbf•ft) 1 in. – 300 Nm (228 lbf•ft) ½ in. – 41 Nm (30 lbf•ft) n/a 5 5 67 – 27 Nm (20 lbf•ft) Cap screw cover/adapter (token bolts) 5 67 – 16 Nm (12 lbf•ft) Bearing carrier set screws Cap screw foot ½ in. – 54 Nm (40 lbf•ft) Cap screws - repeller cover to cover n/a Cap screw – bearing housing ½ in. – 54 Nm (40 lbf•ft) 27 +4/-0 Nm (20 +5/-0 lbf•ft) 54 +7 / -0 Nm (40 +5 / -0 lbf•ft) 95 +7 / -0 Nm (70 +5 / -0 lbf•ft) Bearing Locknut For lubricated or PTFE-coated threads, use 75% of the values given. Gasket joint torque values are for unfilled PTFE gaskets. Other gasket materials may require additional torque to seal. Exceeding metal joint torque values is not recommended. Page 41 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 6.6 Setting impeller clearance and impeller replacement A new impeller gasket [4590.2] must be installed whenever the impeller has been removed from the shaft. Impeller clearance settings may be found in section 5.3. Impeller balancing instruction may be found in section 6.8. Mark 3 Unitized Self-Priming pumps require that the outside diameter of the impeller be 3 mm (0.125 in.) from the casing cutwater. If this close clearance is not maintained the pump may not prime. Do not adjust the impeller clearance with the seal set. Doing so may result in seal leakage and/or damage. The impeller could have sharp edges, which could cause an injury. It is very important to wear heavy gloves. It is recommended that two people install a Group 3 impeller. The weight of a Group 3 impeller greatly increases the chance of thread damage and subsequent lock-up concerns. Do not attempt to tighten the impeller on the shaft by hitting the impeller with a hammer or any other object or by inserting a pry bar between the impeller vanes. Serious damage to the impeller may result from such actions. Care should be taken in the handling of high chrome iron impellers Figure 6-4 6.6.1 Installation and clearance setting for reverse vane impellers on Mark 3 Standard, Unitized self-priming, In-Line and open vane impeller on the recessed impeller pump Flowserve reverse vane impellers and recessed open impellers are set off the cover. This allows the impeller to be set without the casing. Set the impeller clearance by loosening the set screws [6570.3] and rotating the bearing carrier [3240] to obtain the proper clearance. Turn the bearing carrier counter-clockwise until the impeller comes into light rubbing contact with the rear cover. Rotating the shaft at the same time will accurately determine this zero setting. Now, rotate the bearing carrier clockwise to get the proper clearance. Refer to figure 5-12 for the proper impeller clearance based on the operating temperature for the application. Rotating the bearing carrier the width of one of the indicator patterns cast into the bearing carrier moves the impeller axially 0.1 mm (0.004 in.). (See figure 6-5.) Install the impeller [2200] by screwing it onto the shaft (use heavy gloves) until it firmly seats against the shaft shoulder. Tighten the impeller with the impeller wrench from the Flowserve Mark 3 tool kit. To do this, grasp the impeller in both hands and, with the impeller wrench handle to the left (viewed from the impeller end of the shaft - figure 6-3) spin the impeller forcefully in a clockwise direction to impact the impeller wrench handle on the work surface to the right (figure 6-4). Figure 6-3 Page 42 of 68 Indicator pattern Rotation equivalent to 0.1 mm (0.004 in) axial movement Figure 6-5 Determine how far to rotate the bearing carrier by dividing the desired impeller clearance by 0.1 mm (0.004 in) (one indicator pattern). Tightening the set screws [6570.3] will cause the impeller to move 0.05 mm (0.002 in.) closer to the rear cover because of the internal looseness in the bearing carrier threads. This must be considered when setting the impeller clearance. Rotate the bearing carrier clockwise the required amount to get the desired clearance to the cover. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Lastly, uniformly tighten the set screws [6570.3] in incremental steps up to the final torque value to lock the bearing carrier in place. bearing carrier [3240] to obtain the proper clearance. Turn the bearing carrier clockwise until the impeller comes into light rubbing contact with the casing. Rotating the shaft at the same time will accurately determine this zero setting. Now, rotate the bearing carrier counter-clockwise to get the proper clearance. Refer to figure 5-12 for the proper impeller clearance. Rotating the bearing carrier the width of one of the indicator patterns cast into the bearing carrier moves the impeller axially 0.1 mm (0.004 in.). (See figure 6-5.) Figure 6.6 Example: If a pump was to be placed in a service with an operating temperature of 100 °C (212 °F) the impeller setting would be 0.53 mm (0.021 in.) off the rear cover plate. Since it is necessary to add 0.05 mm (0.002 in.) for the movement caused by tightening the set screws an adjustment of 0.58 mm (0.023 in.) is needed. First turn the bearing carrier counter-clockwise until the impeller comes into light rubbing contact with the rear cover. To determine the number of indicator patterns that you will need to rotate the carrier, divide 0.10 into the desired setting; 0.58 / 0.10 = 5.8 (0.023 / 0.004 = 5.8). Rotate the bearing carrier clockwise 6 indicator patterns which will give a clearance of 0.60 mm (0.024 in.). Flowserve suggests that a felt tip pen be used to mark an initial reference point on the bearing housing and the bearing carrier as shown in figure 6-6. Then make a second mark on the bearing carrier 6 indicator patterns counter-clockwise from the initial reference point. Rotate the bearing carrier clockwise until the second mark on the bearing carrier lines up with the initial reference point mark on the bearing housing. Lastly, uniformly tighten the set screws [6570.3] in incremental steps up to the final torque value to lock the bearing carrier in place. 6.6.2 Installation and clearance setting for front vane open style impeller on Mark 3 Standard, Unitized self-priming, Lo-Flo, and In-Line pumps Like all front vane open style impellers, the Flowserve open impeller clearance must be set off the casing. The casing must be installed to accurately set the impeller clearance. (Realizing that this can be very difficult, Flowserve strongly promotes the use of reverse vane impellers, which do not require the presence of the casing to be properly set.) Attach the power end/rear cover plate assembly to the casing. Now set the impeller clearance by loosening the set screws [6570.3] and rotating the Page 43 of 68 Determine how far to rotate the bearing carrier by dividing the desired impeller clearance by 0.1 mm (0.004 in.) (one indicator pattern). Tightening the set screws [6570.3] will cause the impeller to move 0.05 mm (0.002 in.) away from the casing because of the internal looseness in the bearing carrier threads. This must be considered when setting the impeller clearance. Rotate the bearing carrier counterclockwise the required amount to get the desired clearance to the casing. Lastly, uniformly tighten the set screws [6570.3] in incremental steps up to the final torque value to lock the bearing carrier in place. See section 5.3 for impeller clearance settings. Example: If a pump was to be placed in a service with an operating temperature of 150 °C (302 °F) the impeller setting would be 0.69 mm (0.027 in.) off the casing. Since it is necessary to subtract 0.05 mm (0.002 in.) for the movement caused by tightening the set screws an adjustment of 0.64 mm (0.025 in.) is needed. First, turn the bearing carrier clockwise until the impeller comes into light rubbing contact with the casing. To determine the number of indicator patterns that you will need to rotate the carrier, divide 0.10 into the desired setting; 0.64 / 0.10 = 6.4 (.025 / 0.004 = 6.3). Rotate the bearing carrier counter-clockwise 6.5 indicator patterns which will give a clearance of 0.65 mm (0.026 in.). Flowserve suggests that a felt tip pen be used to mark an initial reference point on the bearing housing and the bearing carrier as shown in figure 6-6. Then make a second mark on the bearing carrier 6.5 indicator patterns clockwise from the initial reference point. Rotate the bearing carrier counter-clockwise until the second mark on the bearing carrier lines up with the initial reference point mark on the bearing housing. Lastly, uniformly tighten the set screws [6570.3] in incremental steps up to the final torque value to lock the bearing carrier in place. The impeller is now set for an impeller setting of 0.7 mm (0.028 in.) off the casing. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 The above procedure is fairly straightforward when doing the final setting of the impeller. However it can be quite laborious when doing the preliminary setting in order to establish the location of the mechanical seal. For this reason, the following practice is recommended. Before the pump is taken out of service, adjust the impeller until it touches the casing and then rotate the bearing carrier until the desired impeller clearance is obtained. Identify this location on the bearing carrier and then rotate the bearing carrier until the impeller contacts the rear cover. Record the distance from the desired impeller clearance setting to when the impeller contacts the rear cover. The pump is now removed from the casing and taken to the shop for maintenance. When it is time to set the seal, the impeller is simply set off the rear cover by the same distance recorded earlier. The above technique is only applicable if all of the original pump components are reinstalled. If the casing, cover, impeller or shaft is replaced this method must not be used. 6.6.3 Installation and clearance setting for Sealmatic pumps Install the repeller [2000.1] and covers [1220 and 1220.1] as described in section 6.9.3. Install a seal guide from the Mark 3 tool kit to hold the repeller in place. Set the repeller 0.38 to 0.51 mm (0.015 to 0.020 in.) off the cover following the instruction above in section 6.6.1. Uniformly tighten the set screws [6570.3] in incremental steps up to the final torque value to lock the bearing carrier in place. Remove the seal guide and install the impeller. Check the impeller setting with a feeler gage. The gap should be 0.38 to 0.51 mm (0.015 to 0.020 in.). If the gap is outside of the correct setting, it may be readjusted to get the beat gap at the repeller and impeller. e) Remove the coupling guard. (See section 5.5.) f) Remove the spacer from the coupling. Close coupled pumps required that the motor be removed from the pump assembly. The motor must be fully supported and the jackscrews [6575] loose before removal. g) Remove casing fasteners [6580.1]. On Group 1 In-Line pumps the studs [6572.1] must be removed. h) Remove the fasteners holding the bearing housing foot to the baseplate. (Not applicable on In-Line pumps). i) Move the power end, rear cover, and seal chamber assembly away from the casing. On In-Line pumps the simplest method of power end removal is to first remove the motor and motor adapter with a crane. However this is often not practical and the power end must be removed by hand. This operation is illustrated in figures 6-7, 6-8 and 6-9. Discard the casing/cover gasket [4590.1]. j) The power end and rear cover assembly is heavy. It is important to follow plant safety guidelines when lifting it. Transport the assembly to the maintenance shop. Figure 6-7 6.7 Disassembly 6.7.1 Power end removal a) Before performing any maintenance, disconnect the driver from its power supply and lock it off line. Lock out power to driver to prevent personal injury. b) Close the discharge and suction valves, and drain all liquid from the pump. c) Close all valves on auxiliary equipment and piping, then disconnect all auxiliary piping. d) Decontaminate the pump as necessary. If Flowserve Mark 3 pumps contain dangerous chemicals, it is important to follow plant safety guidelines to avoid personal injury or death. Page 44 of 68 Figure 6-8 Figure 6-9 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 6.7.2 Pump disassembly k) Remove the coupling hub from the pump shaft [2100]. Close coupled pumps require the motor adapter [3160] be removed. l) Using the shaft key [6700], mount the impeller wrench from the Flowserve Mark 3 tool kit (figure 6-1) to the end of the shaft. With the wrench handle pointing to the left when viewed from the impeller end, grasp the impeller [2200] firmly with both hands (wear heavy gloves). By turning the impeller in the clockwise direction move the wrench handle to the 11 o’clock position and then spin the impeller quickly in a counter-clockwise direction so that the wrench makes a sudden impact with a hard surface on the bench. After several sharp raps, the impeller should be free. Unscrew the impeller and remove from the shaft. Discard the impeller gasket [4590.2]. p) If a component type inside mechanical seal [4200] is used, loosen the set screws on the rotating unit and remove it from the shaft (see figure 6-11). Then pull the gland [4120] and stationary seat off the shaft. Remove the stationary seat from the gland. Discard all O-rings and gaskets. Do not apply heat to the impeller. If liquid is entrapped in the hub, an explosion could occur. m) If a cartridge type mechanical seal [4200] is used (figure 6-10), the spacing clips or tabs should be installed prior to loosening the set screws which attaches the seal to the shaft or removing it from the cover. This will ensure that the proper seal compression is maintained. Figure 6-11 q) If a component type outside mechanical seal is used, remove the gland and the stationary seat. Remove the stationary seat from the gland. Loosen the set screws in the rotating unit and remove it from the shaft. Discard all O-rings and gaskets. r) If packing [4130] is used, remove it and the seal cage [lantern ring, 4134]. Remove the gland [4120]. s) If the pump has a hook type sleeve [2400] it can now be removed. Unit now appears as shown in figure 6-12. Figure 6-10 n) Remove the seal or packing gland nuts [6580.2] if so equipped. o) Remove the cover. All pumps except Sealmatic Remove the two cap screws [6570.2] which attach the rear cover [1220] to the adapter. Carefully remove this part. Sealmatic pump only Remove the cap screws that hold the rear cover [1220] to the repeller cover [1220.1]. For Group 3 pumps remove the capscrews [6570.2] that hold the rear cover [1220] to the adapter [1340]. Remove the cover. The repeller is now exposed [2200.1] and should be free to slip from the shaft. In the event it is stuck, the repeller can be pried off by the use of 2 screwdrivers wedged between the repeller [2200.1] and the repeller cover [1220.1]. Page 45 of 68 Figure 6-12 If the power end is oil lubricated, remove the drain plug [6569.1] and drain the oil from the bearing housing [3200]. u) If the pump has lip seals, a deflector [2540] will be present. Remove it. v) Loosen the three set screws [6570.3] on the bearing carrier [3240]. The bearing carrier must be completely unscrewed from the bearing housing. t) Do not pry against the shaft. Mark 3A and ANSI 3A design The face of the bearing carrier has three square lugs that protrude from the surface. The bearing carrier is turned by using an open end wrench on one of the square lugs as shown in figure 6-13. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Mark 3 design On Group 1 and 2 pumps the bearing carrier is turned by using a strap wrench, with the strap located around the outside diameter of the carrier face. On Group 3 pumps, the bearing carrier is turned by using a spanner wrench to engage the cogs on the outside diameter of the bearing carrier. Figure 6-13 w) Because the O-rings [4610.2] will cause some resistance in removing the bearing carrier assembly from the housing, hold the bearing carrier flange firmly and with slight rotation, pull it out of the bearing housing. The bearing carrier assembly with the shaft and bearings should come free. This unit will appear as shown in figure 6-14. Further disassembly is not required unless the bearings are to be replaced. Figure 6-14 x) Remove the snap ring [2530] (see figure 6-15) on Group 1 and 2 pumps, or the bearing retainer [2530.1] on Group 3 pumps. Figure 6-15 Group 1 and 2 pumps equipped with duplex angular contact bearings use a bearing retainer [2530.1] instead of the snap ring. Remove the carrier from the bearing. y) The bearing locknut [3712] and lockwasher [6541.1] may now be removed from the shaft [2100]. Discard the lockwasher. z) An arbor or hydraulic press may be used to remove the bearings [3011 and 3013] from the shaft. It is extremely important to apply even Page 46 of 68 pressure to the inner bearing race only. Never apply pressure to the outer race as this exerts excess load on the balls and causes damage. Applying pressure to the outer race could permanently damage the bearings. aa) The Mark 3A design has an optional oil slinger [2541] located between the bearings. If present, inspect it for damage or looseness. Remove if it needs to be replaced. bb) On Group 2 and 3 pumps, the bearing housing [3200] must be separated from the bearing housing adapter [1340]. The adapter O-ring [4610.1] should be discarded. Mark 3A and ANSI 3A design This is accomplished by removing the cap screws [6570.5], which thread into the bearing housing. Mark 3 In-Line design There is no adapter o-ring [4610.1] when an oil drain tap is supplied in the adapter. Mark 3 design This is accomplished by removing the hex nuts [6580.8] and the cap screws [6570.5]. cc) If lip seals [4310.1 and 4310.2] (see figure 6-16) are used, they should be removed from the bearing carrier and adapter and discarded. Figure 6-16 dd) If the bearing isolators are removed from either the bearing carrier or adapter they must not be reused, discard appropriately. ee) If magnetic seals are used, maintain the seals as specified by the manufacturer. Mark 3 and Mark 3A design Remove the Trico oiler/site gage [3855] (figure 6-17) and oil level tag (figure 6-18) from the bearing housing. ANSI 3A design Remove the site gage [3856] (figure 5-1) and oil level tag (figure 6-18) from the bearing housing. Save these parts for reuse. Figure 6-17 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Diameter/tolerance, under bearings In order to ensure proper fit between the shaft and bearings, verify that both the inboard (IB) and outboard (OB) shaft diameter is consistently within the minimum/maximum values shown in figure 6-20. A micrometer should be used to check these outside diameter (OD) dimensions on the shaft. Figure 6-18 6.8 Examination of parts 6.8.1 Cleaning/inspection All parts should now be thoroughly cleaned and inspected. New bearings, O-rings, gaskets, and lip seals should be used. Any parts that show wear or corrosion should be replaced with new genuine Flowserve parts. It is important that only non-flammable, non-contaminated cleaning fluids are used. These fluids must comply with plant safety and environmental guidelines. 6.8.2 Critical measurements and tolerances To maximize reliability of pumps, it is important that certain parameters and dimensions are measured and maintained within specified tolerances. It is important that all parts be checked. Any parts that do not conform to the specifications should be replaced with new Flowserve parts. 6.8.3 Parameters that should be checked by users Flowserve recommends that the user check the measurements and tolerances in figure 6-19 whenever pump maintenance is performed. Each of these measurements is described in more detail on the following pages. 6.8.4 Additional parameters checked by Flowserve The parameters listed below are somewhat more difficult to measure and/or may require specialized equipment. For this reason, they are not typically checked by our customers, although they are monitored by Flowserve during the manufacturing and/or design process. 6.8.4.1 Shaft and sleeve (if fitted) Replace if grooved, pitted or worn. Prior to mounting bearings or installing the shaft into the bearing housing, check the following parameters: Page 47 of 68 6.8.4.2 Bearings It is recommended that bearings not be re-used after removal from the shaft. Prior to mounting bearings, check the following parameters: Diameter/tolerance, inside diameter In order to ensure proper fit between bearings and the shaft, verify that the inside diameter (ID) of both the IB and OB bearing are consistently within the minimum/maximum values shown in figure 6-20. An inside caliper should be used to check these ID diameters on the bearings. Diameter/tolerance, outside diameter In order to ensure proper fit between bearings and the bearing housing, verify that the OD on both the IB and OB bearings are consistently within the minimum/maximum values shown in figure 6-21. A micrometer should be used to check these outside diameter (OD) dimensions on the bearings. 6.8.4.3 Impeller balancing Shaft whip is deflection where the centerline of the impeller is moving around the true axis of the pump. It is not caused by hydraulic force but rather by an imbalance with the rotating element. Shaft whip is very hard on the mechanical seal because the faces must flex with each revolution in order to maintain contact. To minimize shaft whip it is imperative that the impeller is balanced. All impellers manufactured by Flowserve are balanced after they are trimmed. If for any reason, a customer trims an impeller, it must be re-balanced. See note 1 under figure 6-19 regarding acceptance criteria. 6.8.4.4 Bearing housing/carrier Prior to installing the shaft into the bearing housing, check the following parameters: Diameter/tolerance, at bearing surface In order to ensure proper fit between the bearing housing/carrier and the bearings, verify that the ID of both the IB and OB bearing surfaces are consistently within the minimum/maximum values shown in figure 6-21. An inside caliper should be used to check these ID dimensions in the bearing housing. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Figure 6-19 Figure 6-21 ASME B73.1M standard mm (in.) Topic Suggested by major seal vendors mm (in.) Suggested and/or provided by Flowserve mm (in.) Shaft Diameter tolerance, n/s 0.005 (0.0002) under bearings Impeller Balance See note 1 Bearing housing Diameter (ID) tolerance n/s 0.013 (0.0005) at bearings Power end assembly 0.05 (0.002) 0.03 (0.001) Shaft runout 0.05 (0.002) 0.05 (0.002) 0.05 (0.002) Shaft sleeve runout n/s 0.076 (0.003) 0.05 (0.002) Radial deflection - static Shaft endplay n/s 0.05 (0.002) 0.05 (0.002) Seal chamber Face squareness to shaft 0.08 (0.003) 0.03 (0.001) 0.08 (0.003) Register concentricity 0.13 (0.005) 0.13 (0.005) Complete pump Shaft movement caused n/s 0.05 (0.002) 0.05 (0.002) by pipe strain n/s See note 2 Alignment See note 3 Vibration at bearing housing See note 3 n/s = not specified. 1. The maximum values of acceptable unbalance are: 1 500 r/min: 40 g 8 mm/kg (1 800 r/min: 0.021 oz-in/lb) of mass. 2 900 rpm: 20 g 8 mm/kg (3 600 rpm: 0.011 oz-in/lb) of mass. Flowserve performs a single plane spin balance on most impellers. The following impellers are exceptions: 10X8-14, 10X8-16 and 10X8-16H. On these Flowserve performs a two plane dynamic balance, as required by the ASME B73.1M standard. All balancing, whether single or two plane, is performed to the ISO 1940 Grade 6.3 tolerance criteria. 2. The ASME B73.1M standard does not specify a recommended level of alignment. Flowserve recommends that the pump and motor shafts be aligned to within 0.05 mm (0.002 in.) parallel FIM (full indicator movement) and 0.0005 mm/mm (0.0005 in./in.) angular FIM. Closer alignment will extend MTBPM. For a detailed discussion of this subject see the Alignment section of this manual. 3. The ASME B73.1M, paragraph 5.1.4. Group 1 Group 2 71.999/71.986 110.000/109.985 OB Bearing (2.8346/2.8341) (4.3307/4.3301) bearing/ 71.999/72.017 110.007/110.022 carrier Carrier (2.8346/2.8353) (4.3310/4.3316) mm (in.) 0.031L/0.000L 0.037L/0.007L Fit (0.0012L/0.0000L) (0.0015/0.0003L) 71.999/71.986 110.000/109.985 IB Bearing (2.8346/2.8341) (4.3307/4.3301) bearing/ 71.999/72.017 110.007/110.022 housing Housing (2.8346/2.8353) (4.3310/4.3316) mm (in.) 0.037L/0.007L 0.031L/0.000L Fit (0.0012L/0.0000L) (0.0015L/0.0003L) Group 3 150.000/149.979 (5.9055/5.9047) 150.002/150.030 (5.9056/5.9067) 0.051L/0.002L (0.0020L/0.0001L) 150.000/149.979 (5.9055/5.9047) 150.007/150.025 (5.9058/5.9065) 0.046L/0.007L (0.0018L/0.0003L) 6.8.4.5 Power end Assembled bearing housing, carrier, bearings, and shaft. Shaft/shaft sleeve run-out Shaft run-out is the amount the shaft is “out of true” when rotated in the pump. It is measured by attaching a dial indicator to a stationary part of the pump so that its contact point indicates the radial movement of the shaft surface as the shaft is rotated slowly. If a shaft sleeve is used then shaft sleeve run-out must be checked. It is analogous to shaft run-out. Measurement of shaft runout/shaft sleeve run-out will disclose any out of roundness of the shaft, any eccentricity between the shaft and the sleeve, any permanent bend in the shaft, and/or any eccentricity in the way the shaft or bearings are mounted in the bearing housing. Shaft run-out can shorten the life of the bearings and the mechanical seal. The following diagram shows how to measure shaft/shaft sleeve run-out. Note that both ends need to be checked. The run-out should be 0.025 mm (0.001 in.) FIM or less. Figure 6-20 OB bearing/ shaft mm (in.) IB bearing/ shaft mm (in.) Group 1 Group 2 Group 3 30.000/29.990 50.000/49.987 70.000/69.985 Bearing (1.1811/1.1807) (1.9685/1.9680) (2.7559/2.7553) 30.013/30.003 50.013/50.003 70.015/70.002 Shaft (1.1816/1.1812) (1.9690/1.9686) (2.7565/2.7560) 0.023T/0.003T 0.026T/0.003T 0.030T/0.002T Fit (0.0009T/0.0001T) (0.0010T/0.0001T) (0.0012T/0.0001T) 35.000/34.989 50.000/49.987 70.000/69.985 Bearing (1.3780/1.3775) (1.9685/1.9680) (2.7559/2.7553) 50.013/50.003 70.015/70.002 35.014/35.004 Shaft (1.3785/1.3781) (1.9690/1.9686) (2.7565/2.7560) 0.025T/0.004T 0.026T/0.003T 0.030T/0.002T Fit (0.0010T/0.0001T) (0.0010T/0.0001T) (0.0012T/0.0001T) Page 48 of 68 Runout Radial deflection - static Radial movement of the shaft can be caused by a loose fit between the shaft and the bearing and/or the bearing and the housing. This movement is measured by attempting to displace the shaft vertically by applying an upward force of approximately 4.5 kg (10 lb) to the impeller end of the shaft. While applying this force, the movement of an indicator is observed as shown in the following diagram. The movement should be checked at a point as near as possible to the location of the seal faces. A movement of more than 0.05 mm (0.002 in.) is not acceptable. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Deflection Shaft endplay The maximum amount of axial shaft movement, or endplay, on a Durco pump should be 0.03 mm (0.001 in.) and is measured as shown below. Observe indicator movement while tapping the shaft from each end in turn with a soft mallet. Shaft endplay can cause several problems. It can cause fretting or wear at the point of contact between the shaft and the secondary sealing element. It can also cause seal overloading or underloading and possibly chipping of the seal faces. It can also cause the faces to separate if significant axial vibration occurs. Concentricity 6.8.4.7 Installed pump Complete pump installed. Shaft movement caused by pipe strain Pipe strain is any force put on the pump casing by the piping. Pipe strain should be measured as shown below. Install the indicators as shown before attaching the piping to the pump. The suction and discharge flanges should now be bolted to the piping separately while continuously observing the indicators. Indicator movement should not exceed 0.05 mm (0.002 in.). Endplay 6.8.4.6 Seal chamber Assembled power end and rear cover. Face squareness to shaft Also referred to as “Seal chamber face run-out.” This run-out occurs when the seal chamber face is not perpendicular to the shaft axis. This will cause the gland to cock, which causes the stationary seat to be cocked, which causes the seal to wobble. This runout should be less than 0.08 mm (0.003 in) and should be measured as shown below: Face squareness Register concentricity An eccentric seal chamber bore or gland register can interfere with the piloting and centering of the seal components and alter the hydraulic loading of the seal faces, resulting in reduction of seal life and performance. The seal chamber register concentricity should be less than 0.13 mm (0.005 in.). The diagram below shows how to measure this concentricity. Page 49 of 68 Pipe strain movement Alignment Misalignment of the pump and motor shafts can cause the following problems: • Failure of the mechanical seal • Failure of the motor and/or pump bearings • Failure of the coupling • Excessive vibration/noise The schematics below show the technique for a typical rim and face alignment using a dial indicator. It is important that this alignment be done after the flanges are loaded, and at typical operating temperatures. If proper alignment cannot be maintained a C-flange motor adapter and/or stilt/spring mounting should be considered. Alignment flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Many companies today are using laser alignment which is a more sophisticated and accurate technique. With this method a laser and sensor measure misalignment. This is fed to a computer with a graphic display that shows the required adjustment for each of the motor feet. Full thread length engagement is required for all fasteners. See section 4.8 for recommended final shaft alignment limits. torques. Vibration analysis Vibration analysis is a type of condition monitoring where a pump’s vibration “signature” is monitored on a regular, periodic basis. The primary goal of vibration analysis is extension on MTBPM. By using this tool Flowserve can often determine not only the existence of a problem before it becomes serious, but also the root cause and possible solution. Modern vibration analysis equipment not only detects if a vibration problem exists, but can also suggest the cause of the problem. On a centrifugal pump, these causes can include the following: unbalance, misalignment, defective bearings, resonance, hydraulic forces, cavitation and recirculation. Once identified, the problem can be corrected, leading to increased MTBPM for the pump. Flowserve does not make vibration analysis equipment, however Flowserve strongly urges customers to work with an equipment supplier or consultant to establish an on-going vibration analysis program. See note 3 under figure 6-19 regarding acceptance criteria. 6.9 Assembly of pump and seal It is important that all pipe threads be sealed properly. PTFE tape provides a very reliable seal over a wide range of fluids, but it has a serious shortcoming if not installed properly. If, during application to the threads, the tape is wrapped over the end of the male thread, strings of the tape will be formed when threaded into the female fitting. These strings can then tear away and lodge in the piping system. If this occurs in the seal flush system, small orifices can become blocked effectively shutting off flow. For this reason, Flowserve does not recommend the use of PTFE tape as a thread sealant. Flowserve has investigated and tested alternate sealants and has identified two that provide an effective seal, have the same chemical resistance as the tape, and will not plug flush systems. These are La-co Slic-Tite and Bakerseal. Both products contain finely ground PTFE particles in an oil based carrier. Page 50 of 68 They are supplied in a paste form which is brushed onto the male pipe threads. Flowserve recommends using one of these paste sealants. Refer to figure 6-2 for recommended bolt 6.9.1 Power end assembly The Mark 3A design has an optional oil slinger. If the slinger was removed during disassembly, install a new slinger [2541]. (See figure 6-22.) Figure 6-22 6.9.1.1 Bearing installation Mounting of bearings on shafts must be done in a clean environment. Bearing and power end life can be drastically reduced if even very small foreign particles work their way into the bearings. Wear clean gloves. Bearings should be removed from their protective packaging only immediately before assembly to limit exposure to possible contamination. After removing the packaging they should only come in contact with clean hands, fixtures, tools and work surfaces. The chart shown in figure 6-23 gives the SKF part numbers for bearings in Flowserve Mark 3 pumps. Note that the term “inboard bearing” refers to the bearing nearest to the casing. “Outboard bearing” refers to the bearing nearest to the motor. (See figure 6-22.) Both bearings have a slight interference fit which requires that they be pressed on the shaft with an arbor or hydraulic press. Figure 6-20 identifies the bearing fits. Even force should be applied to only the inner race. Never press on the outer race, as the force will damage the balls and races. An alternate method of installing bearings is to heat the bearings to 93 °C (200 °F) by means of an oven or induction heater. With this approach the bearing must be quickly positioned on the shaft. Never heat the bearings above 110 °C (230 °F). To do so will likely cause the bearing fits to permanently change, leading to early failure. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 a) Install the inboard bearing [3011] on the shaft [2100]. Mark 3A and ANSI 3A design The inboard bearing must be positioned against the shoulder as shown in figure 6-22. Mark 3 design On Group 1 and Group 2 shafts, the inboard bearing must be located as shown in figure 6-24. On Group 3 shafts position the inboard bearing against the shoulder. Figure 6-24: Bearing position - Mark 3 design Mark 3 standard shaft Group A Mark 3 duplex bearing shaft Group A 1 1 68 mm (211/16 in.) 61 mm (23/8 in.) 15 2 2 139 mm (5 /32 in.) 129 mm (53/32 in.) 3 3 * * * Inboard bearing located against shoulder. If the power end is equipped with single shielded regreasable bearings, see figures 5-7 and 5-8 for proper orientation of the shields The orientation of the bearing shields is different for horizontal pumps (figure 5-7) and In-Line pumps (figure 5-8). b) Install the outboard bearing retaining device onto the shaft. Double row bearings Place the snap ring [2530] onto the outboard end of the shaft and slide down to the inboard bearing. The proper orientation of the snap ring must be assured in this step. The flat side of the snap ring must face away from the inboard bearing. Duplex angular contact bearings Place the bearing retainer [2530.1] onto the outboard end of the shaft and slide down to the inboard bearing. The proper orientation of the bearing retainer must be assured in this step. The small side of the retainer must face away from the inboard bearing. Figure 6-23: Flowserve Mark 3 bearings Group Type of bearing 1 2 3 Oil bath/mist - open 1 Regreasable - single shielded 2 Greased for life - double shielded 3 Sealed for life - double sealed 4 Oil bath/mist - open 1 Regreasable – single shielded 2 Greased for life - double shielded 3 Sealed for life - double sealed 4 Oil bath/mist - open 1 Regreasable - single shielded 2 Greased for life - double shielded 3 Sealed for life - double sealed 4 Inboard single row, deep groove 5 Outboard double row, angular contact, deep groove 5 & 9 Optional outboard duplex angular contact 5 6207-C3 6207-ZC3 6207-2ZC3 6207-2RS1C3 6310-C3 6310-ZC3 6310-2ZC3 6310-2RS1C3 6314-C3 6314-ZC3 6314-2ZC3 6314-2RS1C3 5306-AC3 or 3306-AC3 5306-AZC3 or 3306-AZC3 5306-A2ZC3 or 3306-A2ZC3 5306-A2RSC3 or 3306-A2RS1C3 5310-AC3 (AHC3) or 3310-AC3 5310-AZC3 or 3310-AZC3 5310-A2ZC3 or 3310-A2ZC3 5310-A2RSC3 or 3310-A2RS1C3 5314-AC3 or 3314-AC3 5314-AZC3 or 3314-AZC3 5314-A2ZC3 or 3314-A2ZC3 5314-A2RSC3 or 3314-A2RS1C3 7306-BECBY NA 6 NA 7 NA 7 7310-BECBY NA 6 NA 7 NA 7 7314-BECBY NA 6 NA 7 NA 7 Notes: 1. These bearings are open on both sides. They are lubricated by oil bath or oil mist. 2. These bearings are pre-greased by Flowserve. Replacement bearings will generally not be pre-greased, so grease must be applied by the user. They have a single shield, which is located on the side next to the grease buffer, or reservoir. The bearings draw grease from the reservoir as it is needed. The shield protects the bearing from getting too much grease, which would generate heat. The grease reservoir is initially filled with grease by Flowserve. Lubrication fittings are provided, to allow the customer to periodically replenish the grease, as recommended by the bearing and/or grease manufacturer. 3. These bearings are shielded on both sides. They come pre-greased by the bearing manufacturer. The user does not need to regrease these bearings. The shields do not actually contact the bearing race, so no heat is generated. 4. These bearings are sealed on both sides. They come pre-greased by the bearing manufacturer. The user does not need to regrease these bearings. The seals physically contact and rub against the bearing race, which generates heat. These bearings are not recommended at speeds above 1750 r/min. 5. The codes shown are SKF codes. Inboard and outboard bearings have the C3, greater than “normal” clearance. These clearances are recommended by SKF to maximize bearing life. 6. Regreasable - single shielded bearings are not available in the duplex configuration; however, open oil bath-type bearings can be used for the regreasable configuration. These bearings must be pre-greased during assembly. Lubrication fittings are provided, to allow the user to periodically replenish the grease, as recommended by the bearing and/or grease manufacturer. 7. Not available. 8. All bearing configurations are supplied only with steel cages 9. SKF - the 5300 and 3300 bearing series are identical and therefore can be used interchangeably. Page 51 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 c) Install the outboard bearing. Double row bearings Install the outboard bearing [3013] firmly against the shoulder as shown in figure 6-22. If hot bearing mounting techniques are used, steps must be taken to ensure the outboard bearing is firmly positioned against the shaft shoulder. The outboard bearing, while still hot, is to be positioned against the shaft shoulder. Duplex angular contact bearings Duplex angular contact bearings must be mounted back-to-back with the wider thrust sides of the outer races in contact with each other as shown in figure 6-25. Only bearings designed for universal mounting should be used. The SKF designation is “BECB”. NTN’s designation is “G”. A special shaft is required when using duplex angular contact bearings.) Figure 25 The orientation of the bearing shields is different for horizontal pumps (figure 5-7) and In-Line pumps (figure 5-8). It must be understood that fixtures and equipment used to press the bearing must be designed so no load is ever transmitted through the bearing balls. This would damage the bearing. d) After the bearing has cooled below 38 °C (100 °F) the bearing should be pressed against the shaft shoulder. Figure 6-26 identifies the approximate force needed to seat the bearing against the shaft shoulder. If a press is not available the locknut [3712] should be installed immediately after the bearing is placed on the shaft and tightened to ensure the bearing remains in contact with the shaft shoulder. The locknut should then be retightened repeatedly during the time the bearing is cooling. Once cool the locknut should be removed. Figure 6-26 Pump Group 1 Group 2 Group 3 Press force N (lbf) 5 780 (1 300) 11 100 (2 500) 20 000 (4 500) Locknut torque Nm (lbf 8 9 : ; 27 +4/-0 (20 +5/-0) 54 +7/-0 (40 +5/-0) 95 +7/-0 (70 +5/-0) e) Install lockwasher [6541.1] and locknut [3712]. The locknut should be torqued to the value shown in figure 6-26. One tang on the lockwasher must be bent into a corresponding groove on the locknut. Page 52 of 68 6.9.1.2 Bearing housing seals Lip seals If lip seals were used (see figure 6-16), install new lip seals in the bearing carrier [3240] and the housing [3200 - Group 1] or the adapter [1340 - Group 2 and 3]. The lip seals [4310.1 and 4310.2] are double lip style, the cavity between these two lips should be 1/2 to 2/3 filled with grease. When installing this part, the large metal face on the lip seal must face away from the bearings. Labyrinth seals The following are general installation instructions regarding the VBXX Inpro seal. Follow the instructions provided with the seal by the manufacturer. The elastomer O-ring located on the OD of the seal has been sized to overfill the groove in which it is located. When installing the seal into its corresponding housing, in addition to compressing the O-ring a certain amount of material may shear off. This sheared material should be removed. An arbor press should be used to install the seal. Install the inboard seal in the bore of the bearing housing (Group 1) or adapter (Group 2 and Group 3) with the single expulsion port positioned at the 6 o’clock position. Install the outboard seal in the bore of the bearing carrier. There are no orientation issues since this is a multiport design seal. Magnetic seals Follow the installation instructions provided by the manufacturer. 6.9.1.3 Bearing carrier/power end assembly a) Install new O-rings [4610.2] onto the bearing carrier. Be sure to use the correct size O-rings. (The Mark 3 and Mark 3A bearing carriers use different O-rings.) b) Slide the bearing carrier [3240] over the outboard bearing [3013]. c) Install the outboard bearing retaining device. Double row bearings on Group 1 and 2 pumps Slide the snap ring [2530] in place with its flat side against the outboard bearing and snap it into its groove in the bearing carrier. Duplex angular contact bearings on Group 1 and 2 pumps; all bearings on Group 3 pumps Slide the bearing retainer [2530.1] against the outboard bearing and install and tighten the socket head capscrews [6570.12]. See figure 6-2 for correct torque values. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 d) e) f) g) h) Never compress the snap ring unless it is positioned around the shaft and between the bearings. In this configuration, it is contained therefore if it should slip off the compression tool it is unlikely to cause serious injury. The shaft, bearings, and bearing carrier assembly (figure 6-14) can now be installed into the bearing housing [3200]. The bearing carrier [3240] should be lubricated with oil on the O-rings and threads before installing the assembly into the bearing housing. Thread the bearing carrier into the bearing housing by turning it clockwise to engage the threads. Thread the carrier onto the housing until the carrier flange is approximately 3 mm (1/8 in.) from the housing. Install the set screws [6570.3] loosely. Reinstall any tags, plugs, site gages and oiler. Mark 3 and Mark 3A design Install the following items onto the bearing housing; oil level tag (figure 6-18) and combination Trico oiler/site gage [3855], vent/breather [6521] and drain plug [6569.1]. ANSI 3A design Install the following items onto the bearing housing; oil level tag (figure 6-18) and site gage [3855], plug [6521] and magnetic drain plug [6569.4]. On Group 2 and 3 pumps, assemble the bearing housing adapter [1340] to the bearing housing [3200]. Be sure to install a new O-ring [4610.1]. Mark 3 In-Line design The adapter O-ring [4610.1] should not be installed if there is a drain tap in the adapter [1340]. This tap is present on pumps with regreasable bearings and most oil mist applications. Mark 3A and ANSI 3A design Thread the capscrews [6570.5] through the adapter and into the tapped holes in the bearing housing. Mark 3 design Use the capscrews [6570.5] and hexnuts [6580.8]. Orient the bearing housing adapter with the two holes for capscrews [6570.5] on a horizontal line. If the pump has lip seals, install the deflector [2540]. If the pump is equipped with a hook type sleeve [2400], slip it into place over the impeller end of the shaft [2100]. b) Install the rear cover plate [1220] to the bearing housing (Group 1) or the bearing housing adapter (Group 2 and 3) by using the capscrews [6570.2]. Now install the cartridge seal gland to the rear cover plate [1220] using studs [6572.2] and nuts [6580.2]. c) Install the impeller [2200] as instructed in section 6.6. Care should be taken in the handling of high chrome iron impellers. d) Tighten set screws on the seal to lock the rotating unit to the shaft. Finally, remove centering clips from the seal. 6.9.2.2 Component type mechanical seal Review the seal assembly instructions and drawings (seal set dimension) provided by the seal manufacturer. In order to properly set a component seal it is necessary to first locate the shaft in its final axial position. This is accomplished in the following manner. a) Install the rear cover plate [1220] to the bearing housing (Group 1) or the bearing housing adapter (Group 2 and 3) by using the capscrews [6570.2]. b) Install and set the impeller [2200] clearance as outlined in section 6.6. Put blueing on the shaft/ sleeve in the area near the face of the seal chamber (rear cover 1220]. Scribe a mark on the shaft at the face of the seal chamber (figure 6-27). Figure 6-27 c) Remove the impeller and seal chamber (rear cover) following the instructions given in section 6.7 and install a nose cone onto the end of the shaft. Single internal seal installation d) Place the gland [4120] and stationary seat onto the shaft until it lightly touches the bearing housing (Group 1) or adapter (Group 2 and 3). e) Install a gland gasket [4590.3] into the gland. (See figure 6-28.) 6.9.2 Wet end assembly 6.9.2.1 Cartridge mechanical seals Review the seal assembly instructions and drawings provided by the seal manufacturer. a) Install a nose cone on the end of the shaft and then slide the cartridge seal [4200] onto the shaft until it lightly touches the bearing housing [3200] or adapter [1340]. (See figure 6-10.) Page 53 of 68 Figure 6-28 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 f) Locate the rotary seal unit onto the shaft (or sleeve) according to the set dimension provided by the seal manufacture. Tighten set screws on the seal to lock the rotating unit to the shaft/sleeve. g) Install the rear cover plate [1220] to the bearing housing (Group 1) or the bearing housing adapter (Group 2 and 3) by using the capscrews [6570.2]. h) Attach the gland/seat to the rear cover plate [1220] using studs [6572.2] and nuts [6580.2]. Single external seal installation Carry out steps a) to c), above. d) Locate the rotary seal unit onto the shaft/sleeve according to the set dimension provided by the seal manufacturer. Tighten set screws on the seal to lock the rotating unit to the shaft/sleeve. e) Attach the gland [4120] and stationary seat onto rear cover plate [1220] using studs [6572.2] and nuts [6580.2] f) Install the rear cover plate [1220] to the bearing housing (Group 1) or the bearing housing adapter (Group 2 and 3) by using the capscrews [6570.2]. Double seal installation Carry out steps a) to c), above. d) Place the gland [4120] and stationary seat onto the shaft until it lightly touches the bearing housing (Group 1) or adapter (Group 2 and 3). Install a gland gasket [4590.3] into the gland. (See figure 6-28.) e) Locate the rotary seal unit onto the shaft/sleeve according to the set dimension provided by the seal manufacturer. Tighten set screws on the seal to lock the rotating unit to the shaft/sleeve. Install a stationary seat into the rear cover plate [1220]. f) Install the rear cover plate [1220] to the bearing housing (Group 1) or the bearing housing adapter (Group 2 and 3) by using the capscrews [6570.2]. g) Attach the gland/seat to the rear cover plate [1220] using studs [6572.2] and nuts [6580.2]. h) Install the impeller [2200] as instructed in section 6.6. Remember that the impeller clearance is already set. It cannot be changed at this point without resetting the seal. 6.9.2.3 Packing Split gland installation a) Install the rear cover plate [1220] to the bearing housing (Group 1) or the bearing housing adapter (Group 2 and 3) by using the capscrews [6570.2]. b) Install and set the impeller [2200] clearance as outlined in section 6.6. c) Install the packing rings [4130] and seal cage halves [4134] into the stuffing box as shown in figures 4-23 and 4-24. Always stagger the end gaps 90 degrees to ensure a better seal. To speed Page 54 of 68 installation of each ring, have an assistant turn the pump shaft in one direction. This movement of the shaft will tend to draw the rings into the stuffing box. d) A split gland [4120] is an assembly of two matched gland halves that are bolted together. Unbolt the gland halves and install the gland halves around the shaft. Bolt the halves together to form a gland assembly. e) Now install the gland assembly [4120] using studs [6572.2] and nuts [6580.2]. f) Lightly snug up the gland. Final adjustments must be made after the pump has begun operation. One piece gland installation a) Install the gland [4120] over shaft until it lightly touches the bearing housing (Group 1) or adapter (Group 2 and 3). b) Install the rear cover plate [1220] to the bearing housing (Group 1) or the bearing housing adapter (Group 2 and 3) by using the capscrews [6570.2]. c) Install and set the impeller [2200] clearance as outlined in section 6.6. d) Install the packing rings [4130] and seal cage halves [4134] into the stuffing box as shown in figure 4-24. Always stagger the end gaps 90 degrees to ensure a better seal. To speed installation of each ring, have an assistant turn the pump shaft in one direction. This movement of the shaft will tend to draw the rings into the stuffing box. e) Now attach the gland [4120] to the cover using studs [6572.2] and nuts [6580.2]. f) Lightly snug up the gland. Final adjustments must be made after the pump has begun operation. 6.9.2.4 Reassembly - Sealmatic with Checkmatic seal a) Remove any sharpness of edge at wet end of shaft with #400 emery cloth. b) Clean all exposed surfaces of the wet end of the shaft. c) Install a shaft guide tool from the Flowserve tool kit (see figure 6-1). Do not lubricate surfaces. d) Slide one lip seal onto the shaft with a lip facing away from the bearing housing. e) Position the O-ring [4610.10] over the tail of the lip seal (see section 8-3). Slide it all the way to the bearing housing. f) Clean all surfaces of the gland, and install the ceramic into the gland. g) Slide gland/ceramic seat assembly onto the shaft and move it back to the lip seal. h) Slide a second lip seal onto the shaft, with the lip facing the bearing housing, all the way to the ceramic seat. Position the O-ring [4610.10] over the tail of the lip seal. (See section 8-3.) flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 i) Reinstall the repeller cover, repeller, rear cover, and impeller as instructed in section 6.9.3. j) The Checkmatic gland must now be moved forward toward the impeller, pushing the forward lip ahead of it. It is important that the forward lip be firmly loaded against the seat when the gland is seated. Care must be taken to maintain even pressure on both sides of the gland, keeping the lip seal/ceramic seal faces perpendicular to the shaft. k) Tighten the gland nuts evenly. l) Finally, the rear lip must be slipped forward and tight against the seat. Care should be taken so as not to damage the seal face. 6.9.2.5 Reassembly - Sealmatic with dry running seal Component seals will generally require that the wet end is assembled as described in 6.9.3 so that the impeller may be set prior to seal installation. Review the seal assembly instructions and drawings provided by the seal manufacturer. Section 6.9.2.2 contains the general assembly sequences for component seals. 6.9.2.6 Reassembly - Sealmatic with FXP seal a) Remove any sharpness of edge at wet end of shaft with #400 emery cloth. b) Clean all exposed surfaces of the wet end of the shaft. c) Install a shaft guide tool from the Flowserve tool kit. (See figure 6-1.) d) Insert the O-rings into the grooves on the inside diameter of the seal rotor. e) Slide the drive collar onto the shaft until it contacts the bearing housing (pins facing away from bearing housing). f) Lubricate the O-rings and shaft with non-abrasive liquid hand soap and slide the seal rotor onto the shaft until it contacts the rotor drive collar. The notches on the back side of the rotor should face toward the bearing housing. g) Place repeller cover face down on workbench and set the Teflon disk against the gland surface (i.e. end of stuffing box). Attach gland to repeller cover and screw on gland nuts finger-tight. h) Reinstall the repeller cover, repeller, rear cover, and impeller as instructed in section 6.9.3. i) Tighten gland nuts fully. Slide the seal rotor forward until it contacts the Teflon disk. Slide the drive collar forward until its pins are fully engaged in the slots on the back side of the seal rotor. j) Preload the seal by applying even pressure on the back of the drive collar in order to push it and the seal rotor into the Teflon disk. The rotor and drive collar should be moved approximately 3mm ( LQLQWRWKH7HIORQGLVN7LJKWHQWKHGULYH Page 55 of 68 collar setscrews while maintaining pressure on the back of the drive collar. k) Once the pump is flooded, check the seal to ensure it is not leaking. If the seal leaks, repeat step j) above, applying only enough pressure to the drive collar to stop the leak. Do not over tighten the seal. 6.9.3 Sealmatic pump: installation of repeller cover, repeller, cover, and impeller Group 2 pumps - see figure in section 8-3. Group 3 pumps - see figure 6-29. a) For Group 2 pumps, install the repeller cover to the adapter using capscrews [6570.2]. For Group 3 pumps install the repeller cover [1220.1] over the shaft and push it all the way back until it touches the bearing housing. b) Install a new repeller O-ring [4610.11] into the repeller groove. Lubricate the O-ring with liquid soap. c) Install the slip-on repeller [2200.1] onto the shaft. d) Install the repeller cover/cover gasket [4590.9]. e) For Group 2 pumps, install the cover [1220] to the repeller cover using capscrews [6570.13]. For Group 3 pumps, install the cover [1220] to the adapter. Attach to the adapter using capscrews [6570.2]. Attach the repeller cover to the cover using the capscrews [6570.13]. f) The repeller and impeller may now be set following the instructions given in section 6.6.3. 4610.11 4590.9 6570.13 Figure 6-29 - Group 3 Sealmatic Item 4610.11 4590.9 6570.13 Part name Repeller O-ring Gasket – repeller cover Capscrew flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 6.9.4 Close coupled final assembly a) Install the motor adapter [3160] onto the bearing housing using three screws [6570.15]. b) Install unit into casing as described in section 6.9.5. c) Level the unit with the adjustable support feet [3134]. Eliminate soft foot with by adjusting the support feet and or rotating the motor adapter slightly. Bolt the unit to the baseplate and tighten the support feet set screws [6570.17]. d) Reinstall the motor, coupling and coupling guard. 6.9.5 Reassemble to casing a) Install a new rear cover gasket [4590.1] between the rear cover plate [1220] and the casing [1100]. b) Use studs [6572.1] and nuts [6580.1] to complete the rebuild of your Flowserve Mark 3 pump. Page 56 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 7 FAULTS; CAUSES AND REMEDIES The following is a guide to troubleshooting problems with Flowserve Mark 3 pumps. Common problems are analyzed and solutions offered. Obviously, it is impossible to cover every possible scenario. If a problem exists that is not covered by one of the examples, then refer to one of the books listed in section 10, Additional sources of information, or contact a Flowserve sales engineer or distributor/representative for assistance. FAULT SYMPTOM < Pump not reaching design flow rate Pump not reaching design head (TDH) < No discharge or flow with pump running < Pump operates for short period, then loses prime < Excessive noise from wet end < Excessive noise from power end < < < < < = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Page 57 of 68 PROBABLE CAUSES POSSIBLE REMEDIES Recalculate NPSH available. It must be greater than the NPSH Insufficient NPSH. (Noise may not be required by pump at desired flow. If not, redesign suction piping, present.) holding number of elbows and number of planes to a minimum to avoid adverse flow rotation as it approaches the impeller. Reduce system head by increasing pipe size and/or reducing System head greater than anticipated. number of fittings. Increase impeller diameter. (note: Increasing impeller diameter may require use of a larger motor.) 1. Check suction line gaskets and threads for tightness. Entrained air. Air leak from 2. If vortex formation is observed in suction tank, install vortex atmosphere on suction side. breaker. 3. Check for minimum submergence Entrained gas from process. Process generated gases may require larger pumps. Speed too low. Check motor speed against design speed. After confirming wrong rotation, reverse any two of three leads on Direction of rotation wrong. a three phase motor. The pump should be disassembled and inspected before it is restarted. Replace with proper diameter impeller. (NOTE: Increasing Impeller too small. impeller diameter may require use of a larger motor.) Impeller clearance too large. Reset impeller clearance. Plugged impeller, suction line or 1. Reduce length of fiber when possible. casing which may be due to a product 2. Reduce solids in the process fluid when possible. or large solids. 3. Consider larger pump. Wet end parts (casing cover, impeller) Replace part or parts. worn, corroded or missing. Repeat priming operation, recheck instructions. If pump has run Not properly primed. dry, disassemble and inspect the pump before operation. 1. Check and reset impeller clearance. Impeller rubbing. 2. Check outboard bearing assembly for axial end play. Damaged pump shaft, impeller. Replace damaged parts. Redesign suction piping, holding the number of elbows and planes Abnormal fluid rotation due to to a minimum to avoid adverse fluid rotation as it approaches the complex suction piping. impeller. 1. Work with clean tools in clean surroundings. Bearing contamination appearing on 2. Remove all outside dirt from housing before exposing bearings. the raceways as scoring, pitting, 3. Handle with clean dry hands. scratching or rusting caused by 4. Treat a used bearing as carefully as a new one. adverse environment and entrance of 5. Use clean solvent and flushing oil. abrasive contaminants from 6. Protect disassembled bearing from dirt and moisture. atmosphere. 7. Keep bearings wrapped in paper or clean cloth while not in use. 8. Clean inside of housing before replacing bearings. 9. Check oil seals and replace as required. 10. Check all plugs and tapped openings to make sure that they are tight. flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 < Pump not reaching design flow rate Pump not reaching design head (TDH) < No discharge or flow with pump running < Pump operates for short period, then loses prime < Excessive noise from wet end < Excessive noise from power end < < < < < = = = = = PROBABLE CAUSES Brinelling of bearing identified by indentation on the ball races, usually caused by incorrectly applied forces in assembling the bearing or by shock loading such as hitting the bearing or drive shaft with a hammer. False brinelling of bearing identified again by either axial or circumferential indentations usually caused by vibration of the balls between the races in a stationary bearing. Thrust overload on bearing identified by flaking ball path on one side of the outer race or in the case of maximum capacity bearings, may appear as a spalling of the races in the vicinity of the loading slot. (Please note: maximum capacity bearings are not recommended in Mark 3 pumps.) These thrust failures are caused by improper mounting of the bearing or excessive thrust loads. Misalignment identified by fracture of ball retainer or a wide ball path on the inner race and a narrower cocked ball path on the outer race. Misalignment is caused by poor mounting practices or defective drive shaft. For example, bearing not square with the centerline or possibly a bent shaft due to improper handling. POSSIBLE REMEDIES When mounting the bearing on the drive shaft use a proper size ring and apply the pressure against the inner ring only. Be sure when mounting a bearing to apply the mounting pressure slowly and evenly. 1. Correct the source of vibration. 2. Where bearings are oil lubricated and employed in units that may be out of service for extended periods, the drive shaft should be turned over periodically to relubricate all bearing surfaces at intervals of one to three months. Follow correct mounting procedures for bearings. Handle parts carefully and follow recommended mounting procedures. Check all parts for proper fit and alignment. 1. Where current shunting through the bearing cannot be corrected, a shunt in the form of a slip ring assembly should be incorporated. 2. Check all wiring, insulation and rotor windings to be sure that they are sound and all connections are properly made. 3. Where pumps are belt driven, consider the elimination of static charges by proper grounding or consider belt material that is less generative. Bearing damage due to improper 1. Be sure the lubricant is clean. lubrication, identified by one or more 2. Be sure proper amount of lubricant is used. The constant level of the following: oiler supplied with Durco pumps will maintain the proper oil level if 1. Abnormal bearing temperature it is installed and operating properly. In the case of greased rise. lubricated bearings, be sure that there is space adjacent to the 2. A stiff cracked grease appearance. bearing into which it can rid itself of excessive lubricant, otherwise 3. A brown or bluish discoloration of the bearing may overheat and fail prematurely. the bearing races. 3. Be sure the proper grade of lubricant is used. Bearing damaged by electric arcing identified as electro- etching of both inner and outer ring as a pitting or cratering. Electrical arcing is caused by a static electrical charge emanating from belt drives, electrical leakage or short circuiting. = Page 58 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 8 PARTS LIST AND DRAWINGS 8.1 Standard Mark 3 pump, Group 1 Optional duplex arrangement Item 1100 1220 1340 2100 2200 2400 2530.1 2530.2 2540 2541 3011 3013 3126.1 3134 Description Casing Cover Adapter - bearing housing Shaft Impeller Sleeve, optional Retaining ring - bearing Retaining ring - clamp type Deflector - inboard optional Oil flinger - optional Ball bearing - inboard Ball bearing - outboard Shim Support foot Page 59 of 68 3200 3240 3712 3855 3856 4120 4130 4134 4200 4310.1 4310.2 4590.1 4590.2 4590.3 4610.1 Bearing housing Bearing carrier Bearing locknut Constant level oiler (not shown) Sight gage - bearing housing Gland Packing - optional Seal cage – packing optional, Mechanical seal Oil seal inboard Oil seal outboard Gasket - cover Gasket - impeller Gasket - Gland O-ring - adapter 4610.2 6521 6541.1 6569.1 6570.12 6570.2 6570.3 6570.4 6570.5 6572.1 6572.2 6580.1 6580.2 6700 O-ring - bearing carrier Plug - bearing housing vent Lockwasher - bearing Plug - bearing housing drain Screw - clamp Screw - cover/adapter Screw - bearing carrier set Screw - foot Screw - bearing housing Stud - casing Stud - gland Nut - casing Nut - gland Key - shaft/coupling flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 8.2 Standard Mark 3 pump, Group 2 and Group 3 Group 2 Optional duplex bearing arrangement Group 3 Standard bearing clamp arrangement Item 1100 1220 1340 2100 2200 2400 2530.1 2530.2 2540 2541 3011 3013 3126.1 3134 Description Casing Cover Adapter - bearing housing Shaft Impeller Sleeve, optional Retaining ring - bearing Retaining ring - clamp type Deflector - inboard optional Oil flinger - optional Ball bearing - inboard Ball bearing - outboard Shim Support foot Page 60 of 68 3200 3240 3712 3855 3856 4120 4130 4134 4200 4310.1 4310.2 4590.1 4590.2 4590.3 4610.1 Bearing housing Bearing carrier Bearing locknut Constant level oiler (not shown) Sight gage - bearing housing Gland Packing - optional Seal cage – packing optional, Mechanical seal Oil seal inboard Oil seal outboard Gasket - cover Gasket - impeller Gasket - gland O-ring - adapter 4610.2 6521 6541.1 6569.1 6570.12 6570.2 6570.3 6570.4 6570.5 6572.1 6572.2 6580.1 6580.2 6700 O-ring - bearing carrier Plug - bearing housing vent Lockwasher - bearing Plug - bearing housing drain Screw - clamp Screw - cover/adapter Screw - bearing carrier set Screw - foot Screw - bearing housing Stud - casing Stud - gland Nut - casing Nut - gland Key - shaft/coupling flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 8.3 Mark 3 Sealmatic pump, Group 2 Item Description 297 Seat 298 Lipseal 1100 Casing 1220 Cover 1220.1 Cover - repeller 2200 Impeller 2200.1 Repeller 4120 Gland 4200 Mechanical seal 4590.1 Gasket – cover 4590.2 Gasket – impeller 4590.9 Gasket – repeller cover 4610.10 O-ring - lipseal 4610.11 O-ring - repeller 6570.13 Screw – repeller cover 6572.2 Stud - gland 6580.2 Nut - gland Notes: See figure 6-30, GP3 Sealmatic wet end. 8.4 Mark 3 Lo-Flo, Group 2 Item 1100 1220 Page 61 of 68 Description Casing Cover flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 8.5 Mark 3 Unitized Self Priming pump, Group 2 8.6 Mark 3 Recessed Impeller pump, Group 2 Page 62 of 68 Item 1100 2200 4590.1 4590.2 6572.1 6580.1 Description Casing Impeller Gasket – cover Gasket - impeller Stud - casing Nut - casing flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 8.7 Mark 3 In-Line pump, Group 1 Item 1100 1220 2100 2200 2400 2530.1 2530.2 2540 3011 3013 3160 3170* 3200 3240 3712 * Not shown Description Casing Cover Shaft Impeller Sleeve, optional Retaining ring - bearing Retaining ring - clamp type Deflector - inboard optional Ball bearing - inboard Ball bearing - outboard Motor pedestal Pump stand Bearing housing Bearing carrier Bearing locknut Page 63 of 68 4120 4130 4134 4200 4310.1 4310.2 4590.1 4590.2 4590.3 4610.2 6521 6541.1 6541.3 6569.1 6569.3 6570.2 Gland Packing - optional Seal cage – packing optional, Mechanical seal Oil seal inboard Oil seal outboard Gasket - cover Gasket - impeller Gasket - Gland O-ring - bearing carrier Plug - bearing housing vent Lockwasher - bearing Washer Plug Plug – sight gage Screw - cover/adapter 6570.3 6570.12 6570.15* 6572.1 6572.2 6572.3 6575 6580.1 6580.2 6580.3 6580.4 6700 Screw - bearing carrier set Screw - clamp Screw – pump stand Stud - casing Stud - gland Stud – pedestal casing Jackscrew Nut - casing Nut - gland Nut – pedestal casing Nut – jackscrew jam nut Key - shaft/coupling flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 8.8 Mark 3 In-Line pump, Group 2 Item 1100 1220 1340 2100 2200 2400 2530.1 2530.2 2540 3011 3013 3160 3170* 3200 3240 * Not shown Description Casing Cover Adapter - bearing housing Shaft Impeller Sleeve, optional Retaining ring - bearing Retaining ring - clamp type Deflector - inboard optional Ball bearing - inboard Ball bearing - outboard Motor pedestal Pump stand Bearing housing Bearing carrier Page 64 of 68 3712 4120 4130 4134 4200 4310.1 4310.2 4590.1 4590.2 4590.3 4610.1 4610.2 6521 6541.1 6541.3 6569.1 Bearing locknut Gland Packing - optional Seal cage – packing optional, Mechanical seal Oil seal inboard Oil seal outboard Gasket - cover Gasket - impeller Gasket - gland O-ring - adapter O-ring - bearing carrier Plug - bearing housing vent Lockwasher - bearing Washer Plug 6569.3 6570.1 6570.2 6570.3 6570.5 6570.12 6570.15* 6572.2 6572.3 6575 6580.2 6580.3 6580.4 6700 Plug – sight gage Screw - casing Screw - cover/adapter Screw - bearing carrier set Screw - bearing housing Screw - clamp Screw – pump stand Stud - gland Stud – pedestal casing Jackscrew Nut - gland Nut – pedestal casing Nut – jackscrew jam nut Key - shaft/coupling flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 8.9 Mark 3 C-Face Adapter, Group 1 and Group 2 Item 3134 3160 3200 6570.15 6570.16 Description Support foot Motor pedestal – C-Face Bearing housing Screw – bearing housing Screw – coupling guard 6570.17 6572.4 6575 6580.4 6580.5 Screw – foot set screw Stud - motor Jackscrew Nut - jackscrew Nut - motor 8.10 General arrangement drawing The typical general arrangement drawing and any specific drawings required by the contract will be sent to the Purchaser separately unless the contract specifically calls for these to be included into the User Instructions. If required, copies of other drawings sent separately to the Purchaser should be obtained from the Purchaser and retained with these User Instructions. Page 65 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 9 CERTIFICATION Certificates, determined from the contract requirements are provided with these instructions where applicable. Examples are certificates for CE marking and ATEX marking etc. If required, copies of other certificates sent separately to the Purchaser should be obtained from Purchaser for retention with these User Instructions. 10 OTHER RELEVANT DOCUMENTATION AND MANUALS 10.1 Supplementary User Instructions Supplementary instructions such as for a driver, instrumentation, controller, seals, sealant systems etc are provided as separate documents in their original format. If further copies of these are required they should be obtained from the supplier for retention with these User Instructions. 10.2 Change notes If any changes, agreed with Flowserve Pump Division, are made to the product after it is supplied, a record of the details should be maintained with these User Instructions. 10.3 Additional sources of information The following are excellent sources for additional information on Flowserve Mark 3 pumps, and centrifugal pumps in general. Pump Engineering Manual R.E. Syska, J.R. Birk, Flowserve Corporation, Dayton, Ohio, 1980. American National Standard for Vertical Pumps for Nomenclature, Definitions, Design and Application (ANSI/HI 2.1-2.3) Hydraulic Institute, 9 Sylvan Way, Parsippany, New Jersey 07054-3802. American National Standard for Centrifugal Pumps for Installation, Operation, and Maintenance (ANSI/HI 1.4) Hydraulic Institute, 9 Sylvan Way, Parsippany, New Jersey 07054-3802. Flowserve Durco Pump Parts Catalog. Flowserve Mark 3 Sales Bulletin. Flowserve Mark 3 Technical Bulletin (P-10-501). RESP73H Application of ASME B73.1M-1991, Specification for Horizontal End Suction Centrifugal Pumps for Chemical Process, Process Industries Practices Construction Industry Institute, The University of Texas at Austin, 3208 Red River Street, Suite 300, Austin, Texas 78705. Pump Handbook 2nd edition, Igor J. Karassik et al, McGraw-Hill, Inc., New York, NY, 1986. Centrifugal Pump Sourcebook John W. Dufour and William E. Nelson, McGraw-Hill, Inc., New York, NY, 1993. Pumping Manual, 9th edition T.C. Dickenson, Elsevier Advanced Technology, Kidlington, United Kingdom, 1995. Specification for Horizontal End Suction Centrifugal Pumps for Chemical Process, ASME B73.1M The American Society of Mechanical Engineers, New York, NY. Specification for Vertical In-Line Centrifugal Pumps for Chemical Process, ASME B73.2M The American Society of Mechanical Engineers, New York, NY. American National Standard for Centrifugal Pumps for Nomenclature, Definitions, Design and Application (ANSI/HI 1.1-1.3) Hydraulic Institute, 9 Sylvan Way, Parsippany, New Jersey 07054-3802. Page 66 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Notes: Page 67 of 68 flowserve.com MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06 Your Flowserve factory contacts: Flowserve Pump Division 3900 Cook Boulevard Chesapeake, VA 23323-1626 USA Telephone +1 757 485 8000 Fax +1 757 485 8149 Flowserve Pumps Limited PO Box 17, Newark, Notts NG24 3EN United Kingdom Telephone (24 hours) +44 (0)1636 494 600 Sales & Admin Fax +44 (0)1636 705 991 Repair & Service Fax +44 (0)1636 494 833 E.mail inewark@flowserve.com FLOWSERVE REGIONAL SALES OFFICES: USA and Canada Flowserve Corporation 5215 North O’Connor Blvd., Suite 2300 Irving, Texas 75039-5421, USA Telephone +1 972 443 6500 Fax +1 972 443 6800 Europe, Middle East, Africa Worthing S.P.A. Flowserve Corporation Via Rossini 90/92 20033 Desio (Milan), Italy Telephone +39 0362 6121 Fax +39 0362 303 396 Latin America and Caribbean Flowserve Corporation Your local Flowserve representative: 6840 Wynnwood Lane Houston, Texas 77008, USA Telephone +1 713 803 4434 Fax +1 713 803 4497 Asia Pacific Flowserve Pte. Ltd 200 Pandan Loop #06-03/04 Pantech 21 Singapore 128388 Telephone +65 6775 3003 Fax +65 6779 4607 To find your local Flowserve representative please use the Sales Support Locator System found at www.flowserve.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Extract, Print high-res Page Count : 68 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:a58294a5-83d2-47c6-8506-f25d6226220e Creation Date--Text : 16:44 8/30/2006 Producer : GNU Ghostscript 7.05 Creator Tool : Windows NT 4.0 Modify Date : 2007:01:17 11:35:22-05:00 Metadata Date : 2007:01:17 11:35:22-05:00 Document ID : uuid:3966ee6a-a647-11db-b870-00039366f930 Instance ID : uuid:3966f7fc-a647-11db-b870-00039366f930 Format : application/pdf Title : Untitled Document Create Date : 16:44 8/30/2006 Creator : Windows NT 4.0EXIF Metadata provided by EXIF.tools