United Integrated Services WCC-120 Wireless Console Controller User Manual UIS Quick Guide WCC120 V0 1 20100709
United Integrated Services CO., LTD. Wireless Console Controller UIS Quick Guide WCC120 V0 1 20100709
user manual
WCC-120 Quick Installation Guide Confidential WCC-120 / Front View Layout Introduction Emergency key LCD Display Configuration key Cancel key Up / Down key Key to change ARM mode (Full/Partial) Key to bypass sensor error state while arming Enter key Set button Reset button *Configuration mode could be activated in disarm mode only. Confidential WCC-120 / Rear View Battery Adapter Port Tamper-proof detection once unplugged from bracket unexpectedly ! Wall-Mount Bracket Confidential WCC-120 / Accessory Adaptor Bracket Battery *Alkaline AA battery x 2, non-chargeable Confidential Key Definition Confidential Binding...Fail! Device Binding SET button SET button 1. Press WCC-120 “SET” button for 5 seconds 2. Press WG-110 “SET” button for 2 seconds 3. WG-110 Alarm (RED) light ON shortly 4. Waiting for WCC-120 to show “Binding…OK!” 5. If WCC-120 shows “ Binding…..Fail!“, please repeat above steps until binding completed Alarm light Binding...OK! Binding...Fail! Confidential Power ON 1. Please plug in battery or power adapter or both together, the power source is assigned as below: a. battery only – battery power b. power adapter only – DC power c. both – DC power/primary, battery/secondary 2. Complete the device binding procedure as described on last slide 3. Press any key to turn on the power, the screen will show “self testing” while starting to connect to WG-110 Self Testing. 4. The screen will show “self testing ….OK” to mean the successful connectivity with WG-110 Self Testing. OK 5. The screen will be entering into the sleeping (screen save) mode automatically by: a. idle timeout(20sec) in configuration mode b. idle timeout(10sec) in non-configuration mode 6. In sleeping mode, you can recall the system by pressing any key Confidential Operation Tips Press “STAY” key to choose ARM(STAY means Partial ARM, ARM means Full ARM) mode ARM STAYPassword Password *** *** or ARM Password *** key in password to activate ! Waiting !!! Away, Please ! Press key to cancel the setting while counting down Enter Arm (Stay) Mode 20 sec later A w a y, P l e a s e ! You can choose 0/10/20/30 sec of Alarm Delay Time in Arm/Disarm configuration mode Confidential Operation Tips Deactivate ARM / STAY mode ARM Mode or STAY Mode Disarm waiting… Type in password to deactivate Password error! Waiting to Disarm… Wrong password, please try it again Waiting to entering into the disarm mode Confidential Operation Tips 1. Press “PANIC” to trigger emergency alarm immediately 2. Type in password to turn off and return to disarm mode PANIC ALARM! PANIC ALARM! *** password Press “FUNC” to entering into the system configuration mode >System Network Press “BYPASS” to ignore the error sensor state WCS-00001E Please Check! ( Only for WCS--110 sensor ) Confidential 10 Operation Tips LOW Battery ! : When the battery power is below 2.7V, the screen will auto display “ Low Battery! “ to alert. Low Battery! TAMPER ALARM ! : While taking off the wall-mount bracket during ARM / STAY mode, the siren will be triggered automatically. Type in password directly to turn it off. TAMPER ALARM! TAMPER ALARM! Password *** Connect Failed : After the power turned on and doing the self-testing, it will try to connect to the gateway automatically. The screen will display “Timeout” once failed and going into the sleeping mode. Self Testing… Join WG-110 Timeout! Confidential 11 Main Menu WCC-120 Configuration Main Function Sub-Menu Password System Clock Language Reset Network Description The default password is “123”, you may change it once required. System Date/Time English/Chinese Restore to the factory default Reboot Re-start the system WAN Configure the WAN interface WLAN Configure the WLAN interface Arm/Disarm Arm Delay Time Repeater Repeater list Set the Arm Delay Time while arming the system Display the connected repeater list Confidential 12 Main Menu WCC-120 Configuration Main Function Sub-Menu Sensor Sensor list Display and configure the sensors Delay Time Set the alarm delay time while triggering the selected sensors Sensor AL Delay Description Sensor List Sensor Remove SMS Configure SMS notification setting Email Configure E-mail notification setting Notification Confidential 13 Breakdown Menu WCC-120 Configuration Main Function Sub-Tree1 Sub-Tree2 Sub-Tree3 Title (Display) Value (key in) Old Password Old Password Number New Password New Password Number Clock System Time 2010/05/20 15:48 (up/down/bypass key) Language Language English/Chinese (up/down key) Reset Reset Yes >Cancel Reboot Reboot Yes >Cancel Password System Confidential 14 Breakdown Menu WCC-120 Configuration Main Function SubTree1 SubTree2 Sub-Tree3 Title (Display) Value (key in) WAN Mode DHCP/PPPoE/Static/3GPP (up/down key) PPPoE UserName PPPoE UserName Text/Number PPPoE Password PPPoE Password Text/Number Static IP Static IP 0.0.0.0 Static Mask Static Mask 255.255.255.0 Gateway Gateway 0.0.0.0 DNS DNS 0.0.0.0 ISP ISP Text/Number APN APN Text/Number SSID SSID Text/Number Network Key Network Key Number WAN Mode PPPoE WAN Static Network 3GPP WLAN Confidential 15 Breakdown Menu WCC-120 Configuration Main Function Sub-Tree1 Arm/Disarm Sub-Tree2 Sub-Tree3 Title (Display) Value (key in) Arm Delay Time Arm Delay Time 0/10/20/30 (up/down key) RP-00000000002A Del?00000000002A Yes >Cancel RP-00000000002C Del?00000000002C Yes >Cancel Repeater Confidential 16 Breakdown Menu WCC-120 Configuration Main Function Sub-Tree1 Sub-Tree2 Sub-Tree3 Title (Display) Value (key in) WMS Name Name:WMS-000001 Text/Number WMS Partial Arm WMS Partial Arm Enable >Disable WMS Alarm Timer WMS Alarm Timer 0/10/20/30 (up/down key) Add?WLC-000001 Yes >Cancel ... ... WLC-000005 Add?WLC-000005 Yes >Cancel WPC-000002 Remove?WPC000002 Yes >Cancel ... ... ... WLC-000004 Remove?WPC000004 Yes >Cancel Del?WMS-000001 Yes >Cancel WLC-000001 WPC-000002 WMS Link Sensor ... WMS-000001 WPC-000004 WMS Linked WMS Del Confidential 17 Breakdown Menu WCC-120 Configuration Main Function Sub-Tree1 Sub-Tree2 Sub-Tree3 Title (Display) Value (key in) WTS Name Name:WTS-000002 Text/Number WTS Siren Alarm WTS Siren Alarm Enable >Disable WTS F/C WTS F/C oC >oF WTS Value WTS Value 81<=26<=140 (up/down/bypass key) Add?WLC-000001 Yes >Cancel ... ... WPC-000005 Add?WLC-000005 Yes >Cancel WPC-000002 Remove?WPC-000002 Yes >Cancel ... ... ... WLC-000004 Remove?WPC-000004 Yes >Cancel Del?WTS-000002 Yes >Cancel WLC-000001 WPC-000002 Sensor WTS-000002 WTS Link ... WLC-000004 WTS Linked WTS Del Confidential 18 Breakdown Menu WCC-120 Configuration Main Function Sub-Tree1 Sub-Tree2 Sub-Tree3 Title (Display) Value (key in) WCS Status WCS Status >Open Close WCS Name Name:WCS-000003 Text/Number WCS Partial Arm WCS Partial Arm Enable >Disable Add?WLC-000001 Yes >Cancel ... ... WPC-000005 Add?WLC-000005 Yes >Cancel WPC-000002 Remove?WPC-000002 Yes >Cancel ... ... ... WLC-000004 Remove?WPC-000004 Yes >Cancel Del?WCS-000003 Yes >Cancel WLC-000001 WPC-000002 WCS Link Sensor ... WCS-000003 WLC-000004 WCS Linked WCS Del Confidential 19 Breakdown Menu WCC-120 Configuration Main Function Sub-Tree1 Sub-Tree2 Sub-Tree3 Title (Display) Value (key in) WAT Name Name:WAT-000003 Text/Number WAT Siren Alarm WAT Siren Alarm Enable >Disable WAT Value WAT Value 12<= 11<=52 (up/down/bypass key) WAT Threshold WAT Threshold Number Add?WLC-000001 Yes >Cancel ... ... WPC-000005 Add?WLC-000005 Yes >Cancel WPC-000002 Remove?WPC-000002 Yes >Cancel ... ... ... WLC-000004 Remove?WPC-000004 Yes >Cancel Del?WAT-000004 Yes >Cancel WLC-000001 WPC-000002 Sensor WAT-000004 WAT Link ... WLC-000004 WAT Linked WAT Del Confidential 20 Breakdown Menu WCC-120 Configuration Main Function Sub-Tree1 Sub-Tree2 Sub-Tree3 Title (Display) Value (key in) WDT Name Name:WDT-000005 Text/Number WDT Siren Alarm WDT Siren Alarm Enable >Disable Add?WLC-000001 Yes >Cancel ... ... WPC-000005 Add?WPC-000005 Yes >Cancel WPC-000002 Remove?WPC-000002 Yes >Cancel ... ... ... WLC-000004 Remove?WLC-000004 Yes >Cancel Del?WDT-000005 Yes >Cancel WLC-000001 WPC-000002 WDT Link Sensor WDT-000005 ... WLC-000004 WDT Linked WDT Del Confidential 21 Breakdown Menu WCC-120 Configuration Main Function Sub-Tree1 Sub-Tree2 Sub-Tree3 Title (Display) Value (key in) Name:WSS-000006 Text/Number Add?WLC-000001 Yes >Cancel ... ... WPC-000005 Add?WPC-000005 Yes >Cancel WPC-000002 Remove?WPC-000002 Yes >Cancel ... ... ... WLC-000004 Remove?WLC-000004 Yes >Cancel Del?WSS-000006 Yes >Cancel Delay Time 0/30/45/60 (up/down key) WCS-000003 Add?WCS-000003 Yes >Cancel WMS-000001 Remove?WMS000001 Yes >Cancel WSS Name WLC-000001 WPC-000002 ... WSS Link WLC-000004 Sensor WSS-000006 WSS Linked WSS Del Delay Time WMS-000001 Sensor AL Delay Sensor List Sensor Remove Confidential 22 Breakdown Menu WCC-120 Configuration Main Function Sub-Tree1 SMS Sub-Tree2 Title (Display) Value (key in) SMS Enable SMS Enable Enable >Disable PhoneNo.1 PhoneNo.1 Number PhoneNo.2 PhoneNo.2 Number PhoneNo.3 PhoneNo.3 Number PhoneNo.4 PhoneNo.4 Number Service Service Enable >Disable SMTP Server SMTP Server Text/Number Authentication Authentication Enable >Disable User Name User Name Text/Number Password Password Text/Number Email Address Email Address Text/Number Notification Sub-Tree3 Email 1 Email Email 2 Email 3 Email 4 Confidential 23
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 About : 599685a4-96d5-11df-0000-2f3ca39f52ac Producer : GPL Ghostscript 8.63 Keywords : Modify Date : 2010:08:03 19:01:32+08:00 Create Date : 2010:07:21 11:40:50+08:00 Creator Tool : PDFCreator Version 0.9.6 Metadata Date : 2010:08:03 19:01:32+08:00 Document ID : 599685a4-96d5-11df-0000-2f3ca39f52ac Instance ID : uuid:f2da5056-39a1-4239-8541-69b180fceb87 Format : application/pdf Title : UIS-Quick Guide-WCC120_V0 1_20100709 Creator : Aceruser Description : Page Count : 24 Subject : Author : AceruserEXIF Metadata provided by EXIF.tools