United Integrated Services WCC-120 Wireless Console Controller User Manual UIS Quick Guide WCC120 V0 1 20100709

United Integrated Services CO., LTD. Wireless Console Controller UIS Quick Guide WCC120 V0 1 20100709

user manual

Download: United Integrated Services WCC-120 Wireless Console Controller User Manual UIS Quick Guide WCC120 V0 1 20100709
Mirror Download [FCC.gov]United Integrated Services WCC-120 Wireless Console Controller User Manual UIS Quick Guide WCC120 V0 1 20100709
Document ID1321628
Application ID4dD61DvWDhaw1+/DKy5mLw==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize82.91kB (1036415 bits)
Date Submitted2010-08-04 00:00:00
Date Available2010-08-26 00:00:00
Creation Date2010-07-21 11:40:50
Producing SoftwareGPL Ghostscript 8.63
Document Lastmod2010-08-03 19:01:32
Document TitleUIS-Quick Guide-WCC120_V0 1_20100709
Document CreatorPDFCreator Version 0.9.6
Document Author: Aceruser

WCC-120
Quick Installation Guide
Confidential
WCC-120 / Front View
Layout Introduction
Emergency
key
LCD Display
Configuration
key
Cancel key
Up / Down key
Key to change ARM
mode (Full/Partial)
Key to bypass sensor
error state while arming
Enter key
Set button
Reset button
*Configuration mode could be activated in
disarm mode only.
Confidential
WCC-120 / Rear View
Battery
Adapter Port
Tamper-proof detection once unplugged
from bracket unexpectedly !
Wall-Mount Bracket
Confidential
WCC-120 / Accessory
Adaptor
Bracket
Battery
*Alkaline AA battery x 2, non-chargeable
Confidential
Key Definition
Confidential
Binding...Fail!
Device Binding
SET button
SET button
1.
Press WCC-120 “SET” button for 5 seconds
2.
Press WG-110 “SET” button for 2 seconds
3.
WG-110 Alarm (RED) light ON shortly
4.
Waiting for WCC-120 to show “Binding…OK!”
5.
If WCC-120 shows “ Binding…..Fail!“, please
repeat above steps until binding completed
Alarm light
Binding...OK!
Binding...Fail!
Confidential
Power ON
1.
Please plug in battery or power adapter or both together, the power source is assigned as below:
a. battery only – battery power
b. power adapter only – DC power
c. both – DC power/primary, battery/secondary
2.
Complete the device binding procedure as described on last slide
3.
Press any key to turn on the power, the screen will show “self testing” while starting to connect to
WG-110
Self Testing.
4.
The screen will show “self testing ….OK” to mean the successful connectivity with WG-110
Self Testing.
OK
5.
The screen will be entering into the sleeping (screen save) mode automatically by:
a. idle timeout(20sec) in configuration mode
b. idle timeout(10sec) in non-configuration mode
6.
In sleeping mode, you can recall the system by pressing any key
Confidential
Operation Tips
Press “STAY” key to choose ARM(STAY means Partial ARM, ARM means Full ARM) mode
ARM
STAYPassword
Password
***
***
or
ARM Password
***
key in password to activate !
Waiting !!!
Away, Please !
Press
key to cancel the setting while counting down
Enter Arm (Stay) Mode
20 sec later
A w a y, P l e a s e !
You can choose 0/10/20/30 sec of Alarm Delay Time in Arm/Disarm configuration mode
Confidential
Operation Tips
Deactivate ARM / STAY mode
ARM Mode
or
STAY Mode
Disarm
waiting…
Type in password to deactivate
Password error!
Waiting to Disarm…
Wrong password, please try it again
Waiting to entering into the disarm mode
Confidential
Operation Tips
1. Press “PANIC” to trigger emergency alarm immediately
2. Type in password to turn off and return to disarm mode
PANIC ALARM!
PANIC ALARM!
***
password
Press “FUNC” to entering into the system configuration mode
>System
Network
Press “BYPASS” to ignore the error sensor state
WCS-00001E
Please Check!
( Only for WCS--110 sensor )
Confidential
10
Operation Tips
LOW Battery ! : When the battery power is below 2.7V, the screen will auto display “ Low Battery! “ to alert.
Low Battery!
TAMPER ALARM ! : While taking off the wall-mount bracket during ARM / STAY mode, the siren will
be triggered automatically. Type in password directly to turn it off.
TAMPER ALARM!
TAMPER ALARM!
Password
***
Connect Failed : After the power turned on and doing the self-testing, it will try to connect to the gateway
automatically. The screen will display “Timeout” once failed and going into the sleeping
mode.
Self Testing…
Join WG-110
Timeout!
Confidential
11
Main Menu
WCC-120 Configuration
Main Function
Sub-Menu
Password
System
Clock
Language
Reset
Network
Description
The default password is “123”, you may change it once
required.
System Date/Time
English/Chinese
Restore to the factory default
Reboot
Re-start the system
WAN
Configure the WAN interface
WLAN
Configure the WLAN interface
Arm/Disarm
Arm Delay Time
Repeater
Repeater list
Set the Arm Delay Time while arming the system
Display the connected repeater list
Confidential
12
Main Menu
WCC-120 Configuration
Main Function
Sub-Menu
Sensor
Sensor list
Display and configure the sensors
Delay Time
Set the alarm delay time while triggering the selected
sensors
Sensor AL Delay
Description
Sensor List
Sensor Remove
SMS
Configure SMS notification setting
Email
Configure E-mail notification setting
Notification
Confidential
13
Breakdown Menu
WCC-120 Configuration
Main Function
Sub-Tree1
Sub-Tree2
Sub-Tree3
Title (Display)
Value (key in)
Old Password
Old Password
Number
New Password
New Password
Number
Clock
System Time
2010/05/20 15:48 (up/down/bypass key)
Language
Language
English/Chinese (up/down key)
Reset
Reset
Yes >Cancel
Reboot
Reboot
Yes >Cancel
Password
System
Confidential
14
Breakdown Menu
WCC-120 Configuration
Main
Function
SubTree1
SubTree2
Sub-Tree3
Title (Display)
Value (key in)
WAN Mode
DHCP/PPPoE/Static/3GPP
(up/down key)
PPPoE
UserName
PPPoE
UserName
Text/Number
PPPoE Password
PPPoE Password
Text/Number
Static IP
Static IP
0.0.0.0
Static Mask
Static Mask
255.255.255.0
Gateway
Gateway
0.0.0.0
DNS
DNS
0.0.0.0
ISP
ISP
Text/Number
APN
APN
Text/Number
SSID
SSID
Text/Number
Network
Key
Network Key
Number
WAN Mode
PPPoE
WAN
Static
Network
3GPP
WLAN
Confidential
15
Breakdown Menu
WCC-120 Configuration
Main Function
Sub-Tree1
Arm/Disarm
Sub-Tree2
Sub-Tree3
Title (Display)
Value (key in)
Arm Delay Time
Arm Delay Time
0/10/20/30 (up/down key)
RP-00000000002A
Del?00000000002A
Yes >Cancel
RP-00000000002C
Del?00000000002C
Yes >Cancel
Repeater
Confidential
16
Breakdown Menu
WCC-120 Configuration
Main Function
Sub-Tree1
Sub-Tree2
Sub-Tree3
Title (Display)
Value (key in)
WMS Name
Name:WMS-000001
Text/Number
WMS Partial Arm
WMS Partial Arm
Enable >Disable
WMS Alarm Timer
WMS Alarm Timer
0/10/20/30 (up/down key)
Add?WLC-000001
Yes >Cancel
...
...
WLC-000005
Add?WLC-000005
Yes >Cancel
WPC-000002
Remove?WPC000002
Yes >Cancel
...
...
...
WLC-000004
Remove?WPC000004
Yes >Cancel
Del?WMS-000001
Yes >Cancel
WLC-000001
WPC-000002
WMS Link
Sensor
...
WMS-000001
WPC-000004
WMS Linked
WMS Del
Confidential
17
Breakdown Menu
WCC-120 Configuration
Main Function
Sub-Tree1
Sub-Tree2
Sub-Tree3
Title (Display)
Value (key in)
WTS Name
Name:WTS-000002
Text/Number
WTS Siren Alarm
WTS Siren Alarm
Enable >Disable
WTS F/C
WTS F/C
oC >oF
WTS Value
WTS Value
81<=26<=140
(up/down/bypass key)
Add?WLC-000001
Yes >Cancel
...
...
WPC-000005
Add?WLC-000005
Yes >Cancel
WPC-000002
Remove?WPC-000002
Yes >Cancel
...
...
...
WLC-000004
Remove?WPC-000004
Yes >Cancel
Del?WTS-000002
Yes >Cancel
WLC-000001
WPC-000002
Sensor
WTS-000002
WTS Link
...
WLC-000004
WTS Linked
WTS Del
Confidential
18
Breakdown Menu
WCC-120 Configuration
Main Function
Sub-Tree1
Sub-Tree2
Sub-Tree3
Title (Display)
Value (key in)
WCS Status
WCS Status
>Open Close
WCS Name
Name:WCS-000003
Text/Number
WCS Partial Arm
WCS Partial Arm
Enable >Disable
Add?WLC-000001
Yes >Cancel
...
...
WPC-000005
Add?WLC-000005
Yes >Cancel
WPC-000002
Remove?WPC-000002
Yes >Cancel
...
...
...
WLC-000004
Remove?WPC-000004
Yes >Cancel
Del?WCS-000003
Yes >Cancel
WLC-000001
WPC-000002
WCS Link
Sensor
...
WCS-000003
WLC-000004
WCS Linked
WCS Del
Confidential
19
Breakdown Menu
WCC-120 Configuration
Main Function
Sub-Tree1
Sub-Tree2
Sub-Tree3
Title (Display)
Value (key in)
WAT Name
Name:WAT-000003
Text/Number
WAT Siren Alarm
WAT Siren Alarm
Enable >Disable
WAT Value
WAT Value
12<= 11<=52
(up/down/bypass key)
WAT Threshold
WAT Threshold
Number
Add?WLC-000001
Yes >Cancel
...
...
WPC-000005
Add?WLC-000005
Yes >Cancel
WPC-000002
Remove?WPC-000002
Yes >Cancel
...
...
...
WLC-000004
Remove?WPC-000004
Yes >Cancel
Del?WAT-000004
Yes >Cancel
WLC-000001
WPC-000002
Sensor
WAT-000004
WAT Link
...
WLC-000004
WAT Linked
WAT Del
Confidential
20
Breakdown Menu
WCC-120 Configuration
Main Function
Sub-Tree1
Sub-Tree2
Sub-Tree3
Title (Display)
Value (key in)
WDT Name
Name:WDT-000005
Text/Number
WDT Siren Alarm
WDT Siren Alarm
Enable >Disable
Add?WLC-000001
Yes >Cancel
...
...
WPC-000005
Add?WPC-000005
Yes >Cancel
WPC-000002
Remove?WPC-000002
Yes >Cancel
...
...
...
WLC-000004
Remove?WLC-000004
Yes >Cancel
Del?WDT-000005
Yes >Cancel
WLC-000001
WPC-000002
WDT Link
Sensor
WDT-000005
...
WLC-000004
WDT Linked
WDT Del
Confidential
21
Breakdown Menu
WCC-120 Configuration
Main Function
Sub-Tree1
Sub-Tree2
Sub-Tree3
Title (Display)
Value (key in)
Name:WSS-000006
Text/Number
Add?WLC-000001
Yes >Cancel
...
...
WPC-000005
Add?WPC-000005
Yes >Cancel
WPC-000002
Remove?WPC-000002
Yes >Cancel
...
...
...
WLC-000004
Remove?WLC-000004
Yes >Cancel
Del?WSS-000006
Yes >Cancel
Delay Time
0/30/45/60 (up/down key)
WCS-000003
Add?WCS-000003
Yes >Cancel
WMS-000001
Remove?WMS000001
Yes >Cancel
WSS Name
WLC-000001
WPC-000002
...
WSS Link
WLC-000004
Sensor
WSS-000006
WSS Linked
WSS Del
Delay Time
WMS-000001
Sensor AL Delay
Sensor List
Sensor Remove
Confidential
22
Breakdown Menu
WCC-120 Configuration
Main Function
Sub-Tree1
SMS
Sub-Tree2
Title (Display)
Value (key in)
SMS Enable
SMS Enable
Enable >Disable
PhoneNo.1
PhoneNo.1
Number
PhoneNo.2
PhoneNo.2
Number
PhoneNo.3
PhoneNo.3
Number
PhoneNo.4
PhoneNo.4
Number
Service
Service
Enable >Disable
SMTP Server
SMTP Server
Text/Number
Authentication
Authentication
Enable >Disable
User Name
User Name
Text/Number
Password
Password
Text/Number
Email Address
Email Address
Text/Number
Notification
Sub-Tree3
Email 1
Email
Email 2
Email 3
Email 4
Confidential
23


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
About                           : 599685a4-96d5-11df-0000-2f3ca39f52ac
Producer                        : GPL Ghostscript 8.63
Keywords                        : 
Modify Date                     : 2010:08:03 19:01:32+08:00
Create Date                     : 2010:07:21 11:40:50+08:00
Creator Tool                    : PDFCreator Version 0.9.6
Metadata Date                   : 2010:08:03 19:01:32+08:00
Document ID                     : 599685a4-96d5-11df-0000-2f3ca39f52ac
Instance ID                     : uuid:f2da5056-39a1-4239-8541-69b180fceb87
Format                          : application/pdf
Title                           : UIS-Quick Guide-WCC120_V0 1_20100709
Creator                         : Aceruser
Description                     : 
Page Count                      : 24
Subject                         : 
Author                          : Aceruser
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XBTWCC-120

Navigation menu