Utica Boilers Ssc Submittal
2015-05-15
: Utica-Boilers Utica-Boilers-Ssc-Submittal-719503 utica-boilers-ssc-submittal-719503 utica-boilers pdf
Open the PDF directly: View PDF
.
Page Count: 6
| Download | |
| Open PDF In Browser | View PDF |
Engineer:____________________________________________ Project Name:________________________________________ Project Location:______________________________________ Contractor:___________________________________________ APPLICATION: Gas fired hot water heating boiler for indoor installations. Approved for closet or alcove installations. For use with natural or liquefied petroleum gases (LP/propane) LP conversion kit provided with the boiler. Wall mounted, optional floor mount kit available. Constructed and hydrostatically tested for maximum allowable working pressure of 150 PSIG (pounds per square inch gauge) in accordance with ASME boiler and pressure vessel code, section IV, rules for construction of heating boilers. BOILERS INCLUDE: • Wall Mount Bracket • Boiler Control Module XX Line voltage/intermittent direct spark ignition. Replaceable fuse /extra spare fuse shipped with the control. XX Controlling premix modulating gas valve and blower. XX User interface with LCD screen display English text—boiler status indication. XX Function Programming Keys - Reset, Menu, Enter and arrow s (+ - ). XX Central Heating CH and Domestic Hot Water DHW setpoints. Domestic hot water priority with programmable maximum priority time. XX Outdoor air sensor. Programmable reset curves and warm weather shutdown or fixed water temperature operation. XX Boost function temperature setting and adjustable boost time . XX Integral multiple boiler control capability up to 15 boilers. Requires an optional system sensor XX Service reminder status. • Boiler Combustion System XXPremix Gas valve and blower assembly with 20-100% modulating firing rate. Turn down ratio (5:1) gas input. XXStainless Steel Fiber Mesh Burner XXFlame Sensor 2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com P/N 240010478 REV B, [06/2014] • UL listed probe type low water cutoff with status indicator lights and test feature. • Heat Exchanger Assembly XX Vertically mounted single piece helical fin tube coil. Manufactured out of 316L stainless steel tubing with 444 stainless steel fins welded onto the coil with a laser automated process. ASME stamped with a 150 psi maximum allowable working pressure. A 30psi safety relief valve is standard. XX Built-in Primary/Secondary manifold and piping system and heat exchanger pump. XX Non-metallic flue gas collector with built in condensate drain trap . • Electrical XX Removable low voltage terminal strip. XX Line voltage junction box with DWH Pump and CH Pump connections. OPTIONAL EQUIPMENT: • Floor mounting stand • Multiple boiler system sensor Models & Capacities Boiler Input Rate (MBH)(1) Size Heating Capacity (MBH) Net AHRI Rating, Water (MBH)(1)(3) AFUE(2) Maximum Minimum (1)(2) UBSSC-050 50 10 46 40 95.0 UBSSC-075 75 15 69 60 95.0 UBSSC-100 100 20 91 79 95.0 UBSSC-150 150 30 139 121 95.0 UBSSC-200 200 40 185 161 95.0 UBSSC-299 299 60 273 239 95.0 * The UBSSC Models are ENERGY STAR rated products. (1) 1000 Btu/hr (British Thermal Units Per Hour) (2) Heating Capacity and AFUE (Annual Fuel Utilization Efficiency) are based on DOE (Department of Energy) test procedures. (3) Net AHRI Ratings based on piping and pickup allowance of 1.15. Contact Technical Support before selecting boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. 2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com P/N 240010478 REV B, [06/2014] Physical Data Models 050/075/100 Width (A) 20" (508mm) 23" (584mm) Height (B) 30" (762mm) 41" (1041mm) Depth (C) 14" (356mm) Bracket (D) 28" (711mm) 40" (1016mm) Height (E) 31" (787mm) 42" (1092mm) Size (F) 1-1/4" NPT 1-1/4" NPT Location (G) 2" (51mm) 2" (51mm) Location (H) 5" (127mm) 3" (76mm) Location (I) 3" (76mm) 4-½" (114mm) Location (J) 4-1/2" (114mm) 4-1/2" (114mm) Size (K) 1/2" NPT 3/4" NPT 3/4" NPT 3/4" NPT Water Connections Gas Connection Condensate Drain Connection (L) Weight 150/200 16.0" (406mm) 18.3" (465mm) Shipping 111 lb (50 kg) ~182 lb (83 kg) ~225 lb (102 kg) Unit 91 lb (41 kg) ~157 lb (71kg) ~195 lb (89 kg) Vent Connector 2" (51mm) 3" (76mm) Vent Connector (J) (C) (G) (H) 299 (D) (E) Combustion Air Safety Relief Valve Connection (¾ NPT) (I) Wall Hanging Bracket (D) (A) Supply Water (F) Gas Connection (B) (K) Return Water (F) Condensate Drain Connection (L) 2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com P/N 240010478 REV B, [06/2014] CLEARANCES Dimension Combustible Materials 050/075/100/150/200/299 Model Top (A) 0" (0 cm) Left Side (B) 0" (0 cm) Right Side (C) 0" (0 cm) Front (D) 0" (0 cm) Back (E) 0" (0 cm) Bottom (F) 0" (0 cm) Combustion Air/Vent Piping 0" (0 cm) Hot Water Piping See local code (1) (2) Service(1)(2) (1) 050/075/100/150/200/299 14" (36 cm) 0" (0 cm) 0" (0 cm) 6" (16 cm) 0" (0 cm) 12" (32 cm) 6" (16 cm) 6" (16 cm) Required distances measured from boiler jacket. Service, proper operation clearance recommendation. A A B C F E E F F FLOOR Utica, NY 13501 F FLOOR Front View 2201 Dwyer Ave. D Side View www.UticaBoilers.com P/N 240010478 REV B, [06/2014] VENTING Flue Gas Location Combustion Air Location Flue Gas Terminals Two Pipe Roof Roof Concentric Side Wall Single Pipe Inside Air Single Pipe Roof Single Pipe Side Wall Two Pipe Side Wall Concentric Inside Air Single Pipe Minimum/Maximum Vent Lengths 2” Pipe 3” Pipe 4” Pipe Model 050 075/100 075/100 150/200 299 299 Minimum 6 ft. (1.8 m) 6 ft. (1.8 m) 6 ft. (1.8 m) 6 ft. (1.8 m) 6 ft. (1.8 m) 6 ft. (1.8 m) Maximum 100 ft. (30.5 m) 50 ft. (15.2 m) 100 ft. (30.5 m) 100 ft. (30.5 m) 25 ft. (7.7 m) 100 ft. (30.5 m) Equivalent Length of Venting Components Component Feet Meters 90° Elbow 5 1.6 45° Elbow 3½ 1.1 2" x 4" Adapter 0 0 3" x 4" Adapter 0 0 Concentric Vent Kit 5 1.6 Polypropylene Flexible Pipe per Foot 2 5/8 0.8 Note: Allowable Venting Materials - Polypropylene, PVC, CPVC and ABS. Tables shown are for vent systems utilizing PVC . Refer to IOM and vent pipe manufacturer’s instructions for equivalent vent lengths and additional information. 2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com P/N 240010478 REV B, [06/2014] 2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com P/N 240010478 REV B, [06/2014]
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2014:02:10 08:58:09-05:00 Creator : Adobe InDesign CS6 (Windows) Modify Date : 2014:06:10 10:16:02-04:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2014:06:10 10:16:02-04:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:35cf4270-f34f-4263-a885-6e317941f198 Original Document ID : xmp.did:ED26EFB1778EE311BC0DEE3BF8290C38 Document ID : xmp.id:247826565B92E3119FCB92E80F0CE442 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:237826565B92E3119FCB92E80F0CE442 Derived From Document ID : xmp.did:BE35C00D918EE311BC0DEE3BF8290C38 Derived From Original Document ID: xmp.did:ED26EFB1778EE311BC0DEE3BF8290C38 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2014:02:10 08:58:10-05:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 6EXIF Metadata provided by EXIF.tools