Utica Boilers Svb Series Ii Brochure

2015-05-15

: Utica-Boilers Utica-Boilers-Svb-Series-Ii-Brochure-719508 utica-boilers-svb-series-ii-brochure-719508 utica-boilers pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadUtica-Boilers Utica-Boilers-Svb-Series-Ii-Brochure-  Utica-boilers-svb-series-ii-brochure
Open PDF In BrowserView PDF
SVB Series II
There Are Some Things You Can Always Depend On...

SVB

Up to 84.4% AFUE Gas Fired Hot Water Boiler
Available in 6 sizes from 42 MBH to 225 MBH.
Dependable Cast Iron Heat Exchanger with Cast Iron Push Nipples.
The Sections and Push Nipples expand at the same rate when
heated. By using similar materials instead of less expensive
gaskets the boiler maintains a water tight seal over time.
• Honeywell High Limit/Electronic Ignition Control.
•
•

- Recessed under the boiler’s protective jacket
- Digital temperature display and diagnostics
- Plug in connection for the inducer fan
- Plug in connection for the system pump

	 Control monitors the water temperature and delays the burner
starting until residual heat has been transferred. This maximizes
efficiency by turning on the burner only when needed.
• Induced Draft Fan - allows flue gases to be pulled through the boiler
and exhausted through a chimney or side-wall vent.
• Textured paint Jacket. Small compact design is ideal for low
clearance installations.
• Limited Lifetime Warranty (Residential Applications)
• Made in the USA

Utica SVB Series II Gas Fired Hot Water Boiler
Dimensional
Diagram
Front

Model

Input Rate
(MBH) (1)

Heating
Capacity
(MBH) (1)

SVB-2
SVB-3
SVB-4
SVB-5
SVB-6
SVB-7

42.5
75
112.5
150
187.5
225

36
63
94
125
155
186

Net AHRI
Rating,
Water
(MBH) (2)
31
55
82
109
135
162

Vent Diameter

To Chimney (3) Horizontal Vent AFUE %
(Category I)
(Category III)
4”
4”
4”
4”
4”
4”

3”
3”
3”
3”
4”
4”

84.4%
83.4%
83.0%
82.7%
82.3%
82.0%

1) 1,000 Btuh = British Thermal Unit Per Hour. Boilers are equipped for altitudes up to 2,000 feet only. For altitudes above 2,000 feet, ratings should be
reduced at the rate of 4% for each 1,000 feet above sea level. Heating Capacity based on D.O.E. (Department of Energy) test procedure.
2) Net AHRI Water Ratings indicate amount of remaining heat input that can be used to heat the radiation or terminal units. Net AHRI Ratings shown are based
on an allowance of 1.15. Selection of boiler size should be based upon “Net AHRI Rating” being equal to or greater than calculated heat loss of building.
Manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements.
(3) Boiler is provided with a 3” x 4” increaser for chimney vent applications. This does not infer that the connection to the chimney will always be 4”.
Please refer to IOM, National Fuel Gas Code, ANSI Z223.1/NFPA54, or applicable provisions of the local building codes for details concerning proper
chimney connections.

General Information (See Installation, Operation and Maintenance Manual for complete instructions)

Combustible Materials (Required) (4)

Clearances

(4) Required
distances
measured from
boiler.

Left Side

Control Panel
(Internally Located)

*Definition of
Alcove is three
sided space
with no wall in
front of boiler.
ANSI standard
for alcove is
18 inches from
appliance to
leading edge of
side walls as
shown in IOM.

Connections
(All Models)
Electrical
Water
Content

Top

6” (152 mm)

Rear

6” (152 mm)

Control Side

8” (203 mm)

Opposite Side

6" (152 mm)

Front (Alcove)*

18” (457 mm)

Flue/Vent Connector

6” (152 mm)

Return/Supply Water 1-1/4”, Gas In 1/2” NPT
120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended)
SVB-2 - 1.75 Gallons, SVB-3 - 3.00 Gallons, SVB-4 - 4.25 Gallons, SVB-5 - 5.50 Gallons,
SVB-6 - 6.75 Gallons, SVB-7 - 8.00 Gallons
Model
A (Width)
B (Height)
C (Depth)
Weight
SVB-2

SVB-3

Dimensions/
Weights

Right Side
231/4"

Standard
Equipment

Options

Certifications

17-1/2”

SVB-5

20-3/4”

SVB-7

27-1/4”

SVB-6

3"

29"

SVB-4

11”

14-1/4”

24”

29”

29”

29”

29”

29”

29”

225 lbs.

265 lbs.

23-1/4”

370 lbs.

23-1/4”

480 lbs.

23-1/4”

322 lbs.

23-1/4”

431 lbs.

Boiler Control Module: Recessed Honeywell Control (High Limit/Electronic Ignition Control).
User Display Interface: Digital Temperature Display.
Heat Exchanger: Cast Iron Sections with Cast Iron Push Nipples.
Combustion: Completely Installed and Wired Gas Control System with Titanium Composite Burners and
Manifold consisting of: Automatic Redundant Combination Gas Valve, 24 Volt Intermittent Pilot Control,
Continuous Retry 100% Shut Off, Combination Pilot Burner/Electrode/Flame Sensor.
Electrical: 24 Volt Transformer, Service Switch.
Safety: Flame Roll-Out Safety Shut-Off (Fuse Link) and Pressure Switch (vent safety shutoff) with Spare
Fuse Link included.
Other: Assembled Boiler with Insulated Jacket, Induced Draft Fan, Combination Temperature/Pressure
Gauge, Circulator Pump, ¾” Drain Valve, 30lb. ASME Relief Valve.

Natural Gas or Propane, Combustible Floor Plate, Fill-Trol, Thimble, Sidewall Vent Hood

C.S.A. Certified For
Natural Gas Or Propane

Tested for 50 psi
ASME Working Pressure

PN 240009708 Rev. 1/15

All ratings and specifications subject to change.

Contractor
Assistance: 800.325.5479

23-1/4”

23-1/4”

P.O. Box 4729
Utica, New York 13504
tel: 315.797.1310 • fax: 315.797.3762
www.uticaboilers.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c014 79.156797, 2014/08/20-09:53:02
Instance ID                     : uuid:8708f95d-8637-ff46-a2c3-c391816969c9
Original Document ID            : adobe:docid:indd:512815ae-3bc8-11e1-8bb3-984a65b969d7
Document ID                     : xmp.id:226e72a1-798e-49d1-9b9d-416df40a2855
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:20199a38-19aa-4824-bc61-ee3890878813
Derived From Document ID        : xmp.did:1D22368E072068118083F5314E9C37A5
Derived From Original Document ID: adobe:docid:indd:512815ae-3bc8-11e1-8bb3-984a65b969d7
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2014 (Macintosh)
History Changed                 : /
History When                    : 2015:01:07 12:35:08-05:00
Create Date                     : 2015:01:07 12:35:08-05:00
Modify Date                     : 2015:01:07 12:35:36-05:00
Metadata Date                   : 2015:01:07 12:35:36-05:00
Creator Tool                    : Adobe InDesign CC 2014 (Macintosh)
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CC 2014 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu