Utica Boilers Svb Series Ii Brochure
2015-05-15
: Utica-Boilers Utica-Boilers-Svb-Series-Ii-Brochure-719508 utica-boilers-svb-series-ii-brochure-719508 utica-boilers pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
SVB Series II There Are Some Things You Can Always Depend On... SVB Up to 84.4% AFUE Gas Fired Hot Water Boiler Available in 6 sizes from 42 MBH to 225 MBH. Dependable Cast Iron Heat Exchanger with Cast Iron Push Nipples. The Sections and Push Nipples expand at the same rate when heated. By using similar materials instead of less expensive gaskets the boiler maintains a water tight seal over time. • Honeywell High Limit/Electronic Ignition Control. • • - Recessed under the boiler’s protective jacket - Digital temperature display and diagnostics - Plug in connection for the inducer fan - Plug in connection for the system pump Control monitors the water temperature and delays the burner starting until residual heat has been transferred. This maximizes efficiency by turning on the burner only when needed. • Induced Draft Fan - allows flue gases to be pulled through the boiler and exhausted through a chimney or side-wall vent. • Textured paint Jacket. Small compact design is ideal for low clearance installations. • Limited Lifetime Warranty (Residential Applications) • Made in the USA Utica SVB Series II Gas Fired Hot Water Boiler Dimensional Diagram Front Model Input Rate (MBH) (1) Heating Capacity (MBH) (1) SVB-2 SVB-3 SVB-4 SVB-5 SVB-6 SVB-7 42.5 75 112.5 150 187.5 225 36 63 94 125 155 186 Net AHRI Rating, Water (MBH) (2) 31 55 82 109 135 162 Vent Diameter To Chimney (3) Horizontal Vent AFUE % (Category I) (Category III) 4” 4” 4” 4” 4” 4” 3” 3” 3” 3” 4” 4” 84.4% 83.4% 83.0% 82.7% 82.3% 82.0% 1) 1,000 Btuh = British Thermal Unit Per Hour. Boilers are equipped for altitudes up to 2,000 feet only. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. Heating Capacity based on D.O.E. (Department of Energy) test procedure. 2) Net AHRI Water Ratings indicate amount of remaining heat input that can be used to heat the radiation or terminal units. Net AHRI Ratings shown are based on an allowance of 1.15. Selection of boiler size should be based upon “Net AHRI Rating” being equal to or greater than calculated heat loss of building. Manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements. (3) Boiler is provided with a 3” x 4” increaser for chimney vent applications. This does not infer that the connection to the chimney will always be 4”. Please refer to IOM, National Fuel Gas Code, ANSI Z223.1/NFPA54, or applicable provisions of the local building codes for details concerning proper chimney connections. General Information (See Installation, Operation and Maintenance Manual for complete instructions) Combustible Materials (Required) (4) Clearances (4) Required distances measured from boiler. Left Side Control Panel (Internally Located) *Definition of Alcove is three sided space with no wall in front of boiler. ANSI standard for alcove is 18 inches from appliance to leading edge of side walls as shown in IOM. Connections (All Models) Electrical Water Content Top 6” (152 mm) Rear 6” (152 mm) Control Side 8” (203 mm) Opposite Side 6" (152 mm) Front (Alcove)* 18” (457 mm) Flue/Vent Connector 6” (152 mm) Return/Supply Water 1-1/4”, Gas In 1/2” NPT 120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended) SVB-2 - 1.75 Gallons, SVB-3 - 3.00 Gallons, SVB-4 - 4.25 Gallons, SVB-5 - 5.50 Gallons, SVB-6 - 6.75 Gallons, SVB-7 - 8.00 Gallons Model A (Width) B (Height) C (Depth) Weight SVB-2 SVB-3 Dimensions/ Weights Right Side 231/4" Standard Equipment Options Certifications 17-1/2” SVB-5 20-3/4” SVB-7 27-1/4” SVB-6 3" 29" SVB-4 11” 14-1/4” 24” 29” 29” 29” 29” 29” 29” 225 lbs. 265 lbs. 23-1/4” 370 lbs. 23-1/4” 480 lbs. 23-1/4” 322 lbs. 23-1/4” 431 lbs. Boiler Control Module: Recessed Honeywell Control (High Limit/Electronic Ignition Control). User Display Interface: Digital Temperature Display. Heat Exchanger: Cast Iron Sections with Cast Iron Push Nipples. Combustion: Completely Installed and Wired Gas Control System with Titanium Composite Burners and Manifold consisting of: Automatic Redundant Combination Gas Valve, 24 Volt Intermittent Pilot Control, Continuous Retry 100% Shut Off, Combination Pilot Burner/Electrode/Flame Sensor. Electrical: 24 Volt Transformer, Service Switch. Safety: Flame Roll-Out Safety Shut-Off (Fuse Link) and Pressure Switch (vent safety shutoff) with Spare Fuse Link included. Other: Assembled Boiler with Insulated Jacket, Induced Draft Fan, Combination Temperature/Pressure Gauge, Circulator Pump, ¾” Drain Valve, 30lb. ASME Relief Valve. Natural Gas or Propane, Combustible Floor Plate, Fill-Trol, Thimble, Sidewall Vent Hood C.S.A. Certified For Natural Gas Or Propane Tested for 50 psi ASME Working Pressure PN 240009708 Rev. 1/15 All ratings and specifications subject to change. Contractor Assistance: 800.325.5479 23-1/4” 23-1/4” P.O. Box 4729 Utica, New York 13504 tel: 315.797.1310 • fax: 315.797.3762 www.uticaboilers.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.6-c014 79.156797, 2014/08/20-09:53:02 Instance ID : uuid:8708f95d-8637-ff46-a2c3-c391816969c9 Original Document ID : adobe:docid:indd:512815ae-3bc8-11e1-8bb3-984a65b969d7 Document ID : xmp.id:226e72a1-798e-49d1-9b9d-416df40a2855 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:20199a38-19aa-4824-bc61-ee3890878813 Derived From Document ID : xmp.did:1D22368E072068118083F5314E9C37A5 Derived From Original Document ID: adobe:docid:indd:512815ae-3bc8-11e1-8bb3-984a65b969d7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Macintosh) History Changed : / History When : 2015:01:07 12:35:08-05:00 Create Date : 2015:01:07 12:35:08-05:00 Modify Date : 2015:01:07 12:35:36-05:00 Metadata Date : 2015:01:07 12:35:36-05:00 Creator Tool : Adobe InDesign CC 2014 (Macintosh) Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 2 Creator : Adobe InDesign CC 2014 (Macintosh)EXIF Metadata provided by EXIF.tools