VALEO Telematik und Akustik PNADB GSM/GPRS/UMTS/HSDPA/HSUPA Module with GPS and GLONASS User Manual
Peiker acustic GmbH & Co. KG GSM/GPRS/UMTS/HSDPA/HSUPA Module with GPS and GLONASS
User manual
NAD6200 Network Access Device Datasheet, Rev. 1.3 september, 2013 PEIKER acustic Confidential and Proprietary ________________________________________________________________________________________________________________________________________ Site 1 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe Revision History Revision 1.0 1.1 1.2 1.3 Date 13.5.2013 17.7.2013 28.8.2013 2.9.2013 Chapter all 10 10 10 Comment Release Insert chapter 10.2 Warning Statements Insert RF Exposure Warning and Notice Insert OEM responsibility to the FCC rules and regulations ________________________________________________________________________________________________________________________________________ Site 2 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe Index of contents Abstract .................................................................................................................................. 9 1. 2. 3. Introduction ................................................................................................................... 10 1.1. Scope ............................................................................................................................. 10 1.2. References ...................................................................................................................... 10 1.3. Audience......................................................................................................................... 10 1.4. Contact information, support ............................................................................................ 10 Overview of the NAD6200 – Module .............................................................................. 11 2.1. Key features .................................................................................................................... 11 2.2. Product variants and Approvals ......................................................................................... 13 Overview HW – Part ....................................................................................................... 14 3.1. Block – Diagram .............................................................................................................. 14 3.2. Pin description of the board to board connector ................................................................. 15 3.3. HW – Features ................................................................................................................ 17 3.3.1. W-WAN connectivity .................................................................................................. 17 3.3.1.1. GSM/EDGE ......................................................................................................... 17 3.3.1.2. UMTS/WCDMA ................................................................................................... 17 3.3.1.3. GNSS ................................................................................................................. 18 3.3.2. Detailed Pin description ............................................................................................. 18 3.3.2.1. Power Supply ..................................................................................................... 18 3.3.2.2. KPD_Power ........................................................................................................ 19 3.3.2.3. RES_IN .............................................................................................................. 19 3.3.2.4. VREG_MSME ...................................................................................................... 20 3.3.2.5. SIM Card ........................................................................................................... 20 3.3.2.6. USB ................................................................................................................... 21 3.3.2.7. GPIOs ................................................................................................................ 22 3.3.2.8. UART................................................................................................................. 24 3.3.2.9. I²C .................................................................................................................... 24 3.3.2.10. I²S ................................................................................................................... 25 3.3.2.11. GPS Pins ........................................................................................................... 26 3.3.3. Antenna ................................................................................................................... 26 3.3.3.1. Antenna connector ............................................................................................. 26 ________________________________________________________________________________________________________________________________________ Site 3 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 3.3.3.2. Antenna Switching .............................................................................................. 27 3.3.3.3. Antenna diagnostics ............................................................................................ 28 3.3.4. Chipset MDM6200 + PM8028 ..................................................................................... 28 3.3.4.1. PM8028 ............................................................................................................. 28 3.3.4.2. MDM6200 .......................................................................................................... 28 3.3.5. Memory.................................................................................................................... 29 4. Application software ...................................................................................................... 30 5. Antenna characteristics ................................................................................................. 31 6. 5.1. Electrical characteristics for the Antenna ............................................................................ 31 5.2. Electrical characteristics for the Bands ............................................................................... 31 5.2.1. Frequencies .............................................................................................................. 31 5.2.2. Power Consumption, Call ........................................................................................... 32 Environmental Specification .......................................................................................... 34 6.1. General information ......................................................................................................... 34 6.2. Temperature Range ......................................................................................................... 34 7. Mechanical Specification ................................................................................................ 35 8. Safety Recommendations according to EN60950-1 ....................................................... 36 9. Evaluation Kit ................................................................................................................. 37 10. Appendix ........................................................................................................................ 39 10.1. AT Command list .......................................................................................................... 39 10.2. Warning Statements ..................................................................................................... 40 ________________________________________________________________________________________________________________________________________ Site 4 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe Index of figures Figure 1: Block diagram of NAD6200 module ....................................................................... 14 Figure 2: board to board pin connector ................................................................................ 16 Figure 3: Mating connector .................................................................................................. 16 Figure 4: Pin description of GSBIs ........................................................................................ 23 Figure 5: Antenna connectors .............................................................................................. 26 Figure 6: FAKRA HF Single connector ................................................................................... 27 Figure 7: FAKRA HF Dual connector ..................................................................................... 27 Figure 8: Mechanical dimensions of the NAD6200 module................................................... 35 Figure 9: Mechanical dimensions of the NAD6200 module (top view) ................................. 35 Figure 10: Evaluation Kit for NAD6200 module .................................................................... 37 ________________________________________________________________________________________________________________________________________ Site 5 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe Index of tables Table 1: References .............................................................................................................. 10 Table 2: Key features of NAD6200 - Module ......................................................................... 11 Table 3: Product variants ..................................................................................................... 13 Table 4: Pin description of the board to board connector .................................................... 15 Table 5: Features of the GPS ................................................................................................ 18 Table 6: Characteristics of GLONASS .................................................................................... 18 Table 7: nominal values of the NAD6200 - module .............................................................. 19 Table 8: Electrical characteristics of KPD_Power ................................................................. 19 Table 9: Electrical characteristics of RES_IN ........................................................................ 20 Table 10: Electrical characteristics of VREG_MSME.............................................................. 20 Table 11: Electrical characteristics of SIM Interface ............................................................ 21 Table 12: Electrical characteristics of USB Interface ............................................................ 21 Table 13: Electrical characteristics of GPIOs ........................................................................ 23 Table 14: Definition of High - and Low - Level for digital inputs and outputs ...................... 24 Table 15: Electrical characteristics of UART Interfaces ........................................................ 24 Table 16: Electrical characteristics of I²C ............................................................................ 25 Table 17: Electrical characteristics of I²S ............................................................................. 25 Table 18: Electrical characteristics of GPS Pins .................................................................... 26 Table 19: switch combinations ............................................................................................. 27 Table 20: Frequencies of supported WCDMA Bands for uplink ............................................. 31 Table 21: Frequencies of supported WCDMA Bands for downlink ........................................ 31 Table 22: Frequencies of supported GSM Bands (Uplink) ..................................................... 31 Table 23: Frequencies of supported GSM Bands (Downlink) ................................................ 31 Table 24: Power Consumption @ TA = +25°C, VPH_PWR = 3.8 V, P = 23 dBm ................... 32 Table 25: Power Consumption @ TA = +25°C, VPH_PWR = 3.8 V, P = 10 dBm ................... 32 Table 26: Power Consumption @ TA = +25°C, VPH_PWR = 3.8 V, P = 0 dBm ..................... 32 Table 27: Power Consumption @ TA = +25°C, VPH_PWR = 3.8 V, Single Slot .................... 32 Table 28: Idle current for GSM and WCDMA......................................................................... 32 Table 29: Operating temperature range ............................................................................... 34 Table 30: AT Command list with description ........................................................................ 39 ________________________________________________________________________________________________________________________________________ Site 6 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe Index of abbreviations 3 GPP 3rd Generation Partnership Project ADC Analog – Digital – Converter DAC Digital – Analog - Converter eCall Emergency Call Gb Gigabit GLONASS Global Satellite navigation system GNSS Global Navigation Satellite System GPIO General Purpose Input Output GPRS General Packet Radio Service GSBI General Serial Bus Interface GSM Global System for Mobile Communications HSDPA High Speed Downlink Packet Access HSIC High Speed Inter – chip Interface HSPA High Speed Packet Access HSUPA High Speed Uplink Packet Access HW Hardware IC Integrated Circuit I²C Inter –Integrated Circuit I²S Inter-IC Sound Interface LDO Low Drop-Out Mbit/s Megabit per second MPP Multi Purpose PIN NAD6200 Network Access Device QCT Qualcomm technology PCM Pulse Code Modulation PCB Printed Circuit Board RF Radio Frequency SDIO SD Input / Output ________________________________________________________________________________________________________________________________________ Site 7 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe SMPS Switched Mode Power Supply SPDIF Sony / Philips Digital Interface SPI Serial Peripheral Interface SIM Subscriber Identity Module SSBI Single – wired Serial Bus Interface SW Software UART Universal Asynchronous Receiver Transmitter UIM User Interface Module UMTS Universal Mobile Telecommunications System USB Universal Serial Bus WCDMA Wideband Code Division Multiple Access W-WAN Wireless Wide Area Network ________________________________________________________________________________________________________________________________________ Site 8 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe Abstract Peiker NAD 6200 Network Access Device ERA – GLONASS / eCall enabled Automotive Grade by Design 10 – Layer design for best possible EMC and RF characteristics At the PA – Area and the Antenna Connector – Area is nothing assembled on bottom side Components integrated for antennas diagnostics Temperature sensors included for temperature management of some parameters Automotive Grade by Application A 500 MHz clocked ARM11 application processor is part of the MDM6200 chipset: - It contains all mandatory application software for ERA-GLONASS / eCall support - The complete emergency call procedure as specified in ETSI standards and the EGTS protocol are implemented - Enables different license models for different UMTS data rates Automotive Grade Characteristics Enhanced lifetime of the device (till 2020) GPS / GLONASS receiver and LNA integrated Operational temperature range -40°C to +85°C Shock resistance up to 200g ________________________________________________________________________________________________________________________________________ Site 9 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 1. Introduction 1.1. Scope This document gives an overview about electrical, functional and mechanical details of the peiker NAD6200 module based on the Qualcomm chipset MDM6200 and PM 8028. 1.2. References Table 1: References Ref. Name ASP-162345-02 (samtec) CLP-120-02-F-D-A-K-TR (samtec) 4369.SMBA.1H10.009 (IMS Connector Systems GmbH) 4408.SMBA.1H10.009 (IMS Connector Systems GmbH) Comment Board to board connector 40-pole Revision Date Mating connector FAKRA HF dual connector 10.09.2007 FAKRA HF single connector 30.01.2008 1.3. Audience Information how integrate the NAD6200 module in other applications. 1.4. Contact information, support Peiker acustic GmbH & Co. KG Max-Planck-Street 32 D – 61381 Friedrichsdorf Web page: http:// www.peiker.de E-Mail: info@peiker.de ________________________________________________________________________________________________________________________________________ Site 10 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 2. Overview of the NAD6200 – Module This chapter gives a general overview of approvals, functionality and product variants of the NAD6200 module. 2.1. Key features Table 2: Key features of NAD6200 - Module Feature Processors Memory GSM,GMSK,EDGE WCDMA, HSDPA, HSUPA GNSS Antenna functions/interface Interfaces Data Communication Software Power supply Application Processor: ARM1136 + L2 cache at 480 MHz Modem DSP: QDSP4000 processor at 147.5 MHz Application DSP: QDSP4000 processor at 162 MHz 512 Mb 16 bit DDR SDRAM 1 Gb NAND flash GSM850,900 Class 4 (2W) GSM1800, 1900 Class 1 (1W) EDGE850, EDGE900 Class E2 (0.5W) EDGE1800, EDGE1900 Class E2 (0.4W) GPRS/EDGE Multi slot class 12 DTM Multi slot class 11 BC1, 2, 5, 6, 8 Class 3 (0.25W) HSDPA CAT 10 (14.4Mbps) HSUPA CAT 6 (5.76Mbps) GPS Glonass Connector for one main antenna Connector for one backup antenna Optional connector for one GPS antenna Antenna diagnostics USB2.0 HS UIM SPI I²C UART Digital Audio1 CSD analog (V.32/V.34) and digital (V110) with 2.4/4.8/9.6/14.4 kbit/s Packet switched data PPP-Stack SMS: - Point-to-Point MT and MO - Text and PDU mode (“binary-SMS”) - transmission of SMS alternatively over CSD and GPRS - Support of MO/MT SMS parallel to circuit switched (voice/data) - Packet switched data connections Firmware and application software independently updatable. Single power supply 3.8 V I²S ________________________________________________________________________________________________________________________________________ Site 11 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe Thermal functions Additional operations Operating Temperature: -40 °C to +85 °C2 DTMF after dialing DTMF configurable Multiple PDP contexts Echo Cancellation / Noise suppression VDA Class 2a fulfilled Speech codecs: - Half rate EFR - Full rate FR - Enhanced Full rate EFR - Adaptive Multi – Rate AMR : Automotive ambience fulfilled ________________________________________________________________________________________________________________________________________ Site 12 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 2.2. Product variants and Approvals Table 3: Product variants Variant EU6 Band 2 Band 5 Band 63 China APAC8 EU6 + GNSS China + GNSS APAC8 + GNSS Band 1 NA7 NA7 + GNSS GSM – Quad Band PTCRB5 Yes n/a n/a Yes Yes n/a ?? Country Approval R&TTE n/a MNO Approval Vodafone AT&T Rogers (in progress) China Unicom Vodafone Yes n/a Vodafone R&TTE n/a Yes Yes n/a ?? n/a GCF4 GPS & Glonass Band 8 FCC FCC SRRC, CCC, NAL In progress AT&T Rogers (in progress) China Unicom SRRC, CCC, NAL Vodafone In progress FCC FCC : It is a part of Band 5. : Weblink to the Webpage of GCF: http://www.globalcertificationforum.org/ : Weblink to the Webpage of PTCRB: http://www.ptcrb.org/ : Germany, Benelux, Italy, Spain, France, Austria, Denmark, Czech Republic : USA, Canada : Japan, Singapore ________________________________________________________________________________________________________________________________________ Site 13 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 3. Overview HW – Part 3.1. Block – Diagram Figure 1: Block diagram of NAD6200 module ________________________________________________________________________________________________________________________________________ Site 14 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 3.2. Pin description of the board to board connector The following table describes the pin out of the board to board connector of the NAD6200 Module. For detailed information about the electrical characteristics of every Pin see chapter 3.3.2 Detailed Pin description. Table 4: Pin description of the board to board connector PIN Signal 10 11 12 13 14 15 16 17 18 19 20 21 22 VPH_PWR GND VPH_PWR GND VPH_PWR GND KPD_POWER VREG_MSME USIM_RST USIM_CLK VREG_USIM USIM_DATA GPIO_73 GPIO_69 GPIO_32_GSBI_1_0 RES_IN GPIO_35_GSBI_1_3 GPIO_33_GSBI_1_1 GPIO_30_GSBI_0_2 GPIO_34_GSBI_1_2 GPIO_47_GSBI_4_3 GPIO_31_GSBI_0_3 Direction related to NAD6200 Input Power Input Power Input Power Input Power Input Power Input Power IN / active low Output Power Output Output Output Power IN/OUT I/O I/O Output IN Output Input Input Input Output Output 23 USB_DP IN/OUT 24 USB_VBUS Input Power 25 USB_DM IN/OUT 26 GND_USB Power 27 28 29 30 31 32 33 34 GPIO_38_GSBI_2_2 GPIO_37_GSBI_2_1 GPIO_36_GSBI_2_0 GPIO_39_GSBI_2_3 GPIO_42_GSBI_3_2 GPIO_43_GSBI_3_3 GPIO_40_GSBI_3_0 GPIO_41_GSBI_3_1 Output Output Output Input Input Output Output IN/OUT Comment Main Power Power GND Main Power Power GND Main Power Power GND NAD6200 switch on input Output power SIM – Card reset SIM – Card clock Output power to SIM – Card SIM – Card data GPIO GPIO 4 - Pin – UART – Ready for receive 1 Force a reset, shut down the PMIC 4 - Pin - UART - TX 1 4 - Pin - UART - clear to send 1 2 - Pin - UART - RX 2 4 - Pin - UART - RX 1 I²S - Master Clock 2 - Pin - UART - TX 2 High – Speed USB Device for communication High – Speed USB Device for communication High – Speed USB Device for communication High – Speed USB Device for communication I²S - Master Clock I²S - word select I²S - clock I²S - data input 2 – Pin – UART – RX 3 2 – Pin – UART – TX 3 I²C – seriel clock I²C – serial data ________________________________________________________________________________________________________________________________________ Site 15 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 35 36 37 38 39 40 GPIO_17 GPIO_14 GPIO_46_GSBI_4_2 GPIO_9 Output Output Output Input OUT / active GPS_ANT_OVERVOLT low EXT_5V5 Input Power NAD-WAKEUP Codec Reset I²S – data output NAD-UPDATE Detection of GPS – Antenna short against + 12 V Power for inside GPS – Antenna LNA Information about the pin connector and mating connector: Figure 2: board to board pin connector Figure 3: Mating connector For detailed information about board to board pin connector see reference 1 and for mating connector see reference 2. Both are in the Table 1: References. ________________________________________________________________________________________________________________________________________ Site 16 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe PIN 2 PIN 1 PIN 40 PIN 39 3.3. HW – Features 3.3.1. 3.3.1.1. W-WAN connectivity GSM/EDGE EGSM850,900 Class 4 (2W) GSM1800, 1900 Class 1 (1W) EDGE850, EDGE900 Class E2 (0.5W) EDGE1800, EDGE1900 Class E2 (0.4W) GPRS/EDGE Multi slot class 12 DTM Multi slot class 11 3.3.1.2. UMTS/WCDMA UMTS / WCDMA are the 3rd generation of mobile telecommunication standard worldwide. HSPA are only an extension of UMTS / WCDMA. WCDMA up to 384 kb/s at uplink/downlink UMTS to GSM handover for both voice and data HSPA: HSDPA: Downlink with at least 14.4. Mbit/s HSUPA: Uplink with at least 5.7 Mbit/s Three different license configurations are realizable for Peiker NAD6200: UMTS Standard with Downlink Rate 384 kBit/s as license option (LDR) UMTS HSDPA with Downlink Rate 3.6 MBit/s as license option UMTS HSDPA+ with Downlink Rate 14.4 MBit/s as license option ________________________________________________________________________________________________________________________________________ Site 17 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 3.3.1.3. GNSS GNSS is used for detection of the position and navigation. In the moment two systems are exist the American version GPS and the Russian version GLONASS. The NAD6200 support GPS and GLONASS. The MDM GNSS RF receiver performance is adequate to ensure compliance to the applicable standards. 3.3.1.3.1. GPS Table 5: Features of the GPS Feature Acquisition sensitivity – MSA Asynchronous A-GPS Cold – start sensitivity Tracking sensitivity Standalone or MSB Accuracy in open sky Standalone time to first fix (super hot/warm/cold/weak signal) 3.3.1.3.2. Value -158 dBm Comment -145 dBm -161 dBm <2m CEP-50 Open sky, 1 Hz tracking 1s / 29s / 32s / 50s GLONASS Table 6: Characteristics of GLONASS Feature Tracking sensitivity 98% Value Tracking sensitivity 98 % normalized to 2.5 dB NF Predicted Mission mode tracking sensitivity normalized to 2.5 dB NF, Pdet = 50% 3.3.2. 3.3.2.1. -155.3 dBm -155.3 dBm -158.2 dBm -158.8 dBm -160.3 dBm -160.9 dBm comment Probability of detection (Pdet) = 0.98 Probability of false alarm (Pfa) = 1e-3 Detailed Pin description Power Supply The NAD6200 Module has 3 Pins (PIN 1, PIN 3 and PIN 5) for the Main Power Supply Voltage (VPH_PWR) and 3 Pins (PIN 2, PIN 4, PIN 6) for the Power Ground (GND). 3.3.2.1.1. Absolute maximum values Voltage supply Current supply Temperature range 3.4….4.2 V 2.5 A @ peak -40°C…+85°C ________________________________________________________________________________________________________________________________________ Site 18 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 3.3.2.1.2. Nominal values Table 7: nominal values of the NAD6200 - module Parameter Voltage supply Current supply Voltage drop @ GSM power burst (33 dBm) for an external voltage regulator 3.3.2.2. 3.3.2.2.1. Min 3.7 Typ 3.8 Max 3.9 2.5 Unit 100 mV KPD_Power Description This signal is used to switch on the NAD6200 module. After the main power VPH_Power (3.8V) is applied to the NAD6200 module, the module will not start automatically. To start the power regulators of the module KPD_Power must be pulled against ground for at least 60 ms. KPD_POWER input has an internal weak pull up against VPH_Power. Due to this fact it is recommended to pull the input against GND using an open drain or open collector circuit. Because of EMC constraints it might be necessary to add an additional stronger pull up against the VPH_Power. It is also possible to connect the KPD_Power input directly to Ground. In this case the module will start up immediately after VPH_Power turned on. 3.3.2.2.2. Electrical characteristics Table 8: Electrical characteristics of KPD_Power PIN Parameter KPD_POWER 3.3.2.3. 3.3.2.3.1. Comment Pull down with open Collector RES_IN Description The reset input can be used either to switch off the module or to reset the module. In case that the module is already powered on and the KPD_Power is in pull up state this signal must be driven against ground for 250 ms to switch off the module. The module will remain switched off until the reset signal is released to pull up state and until there is no new KPD_Power on sequence. In case of that the KPD_Power pin is connected directly to ground the internal regulators of the module will also switch off, but only for a few ms and then a new power on sequence starts automatically. RES_IN input has an internal weak pull up against VREG_MSME (1.8V). Due to this fact it is recommended to pull the input against GND using an open drain or open collector circuit. Because of EMC constraints it might be necessary to add an additional stronger pull up against the VREG_MSME (1.8V). ________________________________________________________________________________________________________________________________________ Site 19 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 3.3.2.3.2. Electrical characteristics Table 9: Electrical characteristics of RES_IN PIN Parameter 16 RES_IN 3.3.2.4. Comment Pull down with open Collector VREG_MSME 3.3.2.4.1. Description VREG_MSME is provided by an internal regulator of the NAD6200 module. VREG_MSME can be used to source interface circuits like level shifters which are connected to the interfaces or GPIOs of the NAD6200 module. The current drawn on VREG_MSME shall not exceed 30 mA. When using VREG_MSME it is recommended to decouple the signal with a combination of 1 µF and 22 pF directly at the board to board connector. 3.3.2.4.2. Electrical characteristics Table 10: Electrical characteristics of VREG_MSME PIN Parameter VREG_MSME 3.3.2.5. Min Max 1.8 30 Unit mA Comment SIM Card 3.3.2.5.1. Description The SIM interface of the NAD6200 module is compatible to 1.8 V and 3 V SIM Cards. Necessary voltage and level shifting is handled by NAD6200 module automatically. The SIM interface consists of the following signals: VREG_USIM: USIM_CLK: USIM_DATA: USIM_RESET: GPIO69: SIM SIM SIM SIM SIM Supply Voltage clock signal data signal reset signal Present Signal9 The data speed on the SIM interface is up to 4 Mbit. Hardware designer should take care of the length and routing of the SIM interface to prevent potential problems. : Software doesn´t support this feature at the moment. ________________________________________________________________________________________________________________________________________ Site 20 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 3.3.2.5.2. Electrical characteristics Table 11: Electrical characteristics of SIM Interface PIN Parameter 11 VREG_USIM Min Max 2.85 / 1.8 150 2.85 /1.8 Unit mA 10 USIM_CLK 12 USIM_DATA 2.85 /1.8 USIM_RESET 2.85 /1.8 14 SIM Present Signal – GPIO69 1.8 3.3.2.6. 3.3.2.6.1. Comments Pull up 22 kΩ against VREG_USIM is required Is not supported yet USB Description The NAD6200 module has one USB 2.0 high speed compliant interface with built-in PHY. The USB Interface consists of 4 signals: USB_DP: USB Data Plus signal USB_DM: USB Data Minus signal USB_VBUS: USB Voltage Supply USB_GND: USB Ground The NAD6200 module is configured as USB – Device on the NAD6200 PCB. This Interface supports the following data rates: At low – speed: 1.5 Mbit/s At full – speed: 12 Mbit/s At high – speed: 480 Mbit/s 3.3.2.6.2. Electrical characteristics Table 12: Electrical characteristics of USB Interface PIN 23 25 Parameter USB_DP USB_DM 24 USB_VBUS 26 USB_GND Min Max 3.3 3.3 5.25 Unit mA Comment It is impossible to supply the module with USB_VBUS only. If there is a requirement that the system must power the USB_VBUS while the module is not switched on, it is strictly recommended to limit the USB_VBUS current to the module by a serial resistor of 22 KΩ. ________________________________________________________________________________________________________________________________________ Site 21 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe The Pin USB_VBUS must be supply a Minimum voltage about 2 V with the serial resistor. 3.3.2.7. 3.3.2.7.1. GPIOs Description There are 21 GPIOs on the board to board connector of the NAD6200 module. Most of them are part of 5 GSBIs and are used for different interfaces (see Table 4 and the following chapters). For dissenting configurations of the GPIOs/GSBIs please contact Peiker acustics GmbH & Co.KG GPIOs and GSBIs share the same output pins and may not available when used as GSBI configuration. The following GPIOs are not belonging to a GSBI bundle: GPIO 9, 14, 69, 17, 73 The following GPIOs are belonging to a GSBI bundle: GPIO 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 46, 47 Available signals on GSBI bundles at the board to board connector: GSBI0: GSBI1: GSBI2: GSBI3: GSBI4: GSBI0_2, GSBI1_0, GSBI2_0, GSBI3_0, GSBI4_2, GSBI0_3 (GPIO_30, 31) GSBI1_1, GSBI1_2, GSBI1_3 (GPIO_32, 33, 34, 35) GSBI2_1, GSBI2_2, GSBI2_3 (GPIO_36, 37, 38, 39) GSBI3_1, GSBI3_2, GSBI3_3 (GPIO_40, 41, 42, 43) GSBI4_3 (GPIO_46, 47) ________________________________________________________________________________________________________________________________________ Site 22 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe For the standard configuration of the GSBIs see the following Figure 4. Figure 4: Pin description of GSBIs For other configuration of the GSBIs please contact Peiker acustics GmbH & Co.KG. 3.3.2.7.2. Electrical characteristics Table 13: Electrical characteristics of GPIOs PIN 13 Parameter GPIO_73 14 GPIO_69 SIM Present Signal 35 36 GPIO_17 – NAD-WAKEUP GPIO_14 – Codec reset Min Max 1.8 Unit 1.8 1.8 1.8 Comment Not implemented yet. Pull down 1 kΩ against Ground ________________________________________________________________________________________________________________________________________ Site 23 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe GPIO_9 – NAD-UPDATE 38 1.8 Pull up 10 kΩ against 1.8 V The following table is valid for all GPIOs and digital inputs and outputs. Table 14: Definition of High - and Low - Level for digital inputs and outputs VIH VIL VSHYS VOH VOL Parameter High-level input voltage Low-level input voltage Hysteresis voltage High-level output voltage Low-level output voltage 3.3.2.8. 3.3.2.8.1. Min Typ Max Unit 0.65*1.8 1.8+0.3 -0.3 0.35*1.8 100 mV 1.8-0.45 1.8 0.45 UART Description The GPIOs 30, 31 and 42, 43 are configured as a 2 – Pin - UART and the GSBI1 are configured as a 4 – Pin - UART. It is used for the following applications: The UART 1 is used for the communication between the NAD6200 module and a CAN Controller The UART 2 is used for log and trace The UART 3 is used for test and debug of the NAD6200 module 3.3.2.8.2. Electrical characteristics Table 15: Electrical characteristics of UART Interfaces PIN 19 22 31 32 15 17 18 20 3.3.2.9. 3.3.2.9.1. Parameter UART – RX2 UART – TX2 UART – RX3 UART – TX3 UART – RFR1 UART – TX1 UART – CTS1 UART – RX1 Min Max 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 Unit I²C Description The I²C – Interface is used for the communication between the CODEC and NAD6200 Module. ________________________________________________________________________________________________________________________________________ Site 24 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 3.3.2.9.2. Electrical characteristics Table 16: Electrical characteristics of I²C PIN 33 34 Parameter Seriel clock Seriel data 3.3.2.10. Min Max 1.8 1.8 Unit I²S 3.3.2.10.1. Description The I²S interface is used to transfer serial digital audio to/from an external stereo DAC/ADC. This interface is a 3 – wire interface: Serial clock Word select Serial data I²S supports all the Tx/Rx slave/master modes: Transmitter – master Transmitter – slave Receiver – master Receiver – slave Master or slave is determined by the device driving the serial clock and word select. The transmitter sends data to the receiver. Bidirectional I²S support is supported by configuring two of the five GSBI ports as I²S; one GSBI as transmitter and the second GSBI as receiver. Two options are possible: Option 1: MDM as master (transmitter or receiver) and slave (transmitter or receiver); external device as slave. The MDM transmitter and receiver cannot both be the master at the same time as there will be data contention. Option 2: Both MDM transmitter and receiver are slave; external device as master. At the standard configuration the NAD6200 module is master and the Codec slave. For other configuration please contact Peiker acustics GmbH & Co.KG. 3.3.2.10.2. Electrical characteristics Table 17: Electrical characteristics of I²S PIN 27 / 21 28 29 30 37 36 Parameter Min Max Unit Master Clock 1.8 Word Select Clock Data input Data output GPIO_14 – codec reset 1.8 1.8 1.8 1.8 1.8 ________________________________________________________________________________________________________________________________________ Site 25 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 3.3.2.11. GPS Pins 3.3.2.11.1. Description The PIN GPS_ANT_OVERVOLT and EXT_5V5 are reserved for use of the internal GPS of the NAD6200 module. The PINs should be grounded when not used in the design. 3.3.2.11.2. Electrical characteristics Table 18: Electrical characteristics of GPS Pins PIN Parameter Min Max Unit 39 GPS_ANT_OVERVOLT 40 EXT_5V5 5.5 100 mA 3.3.3. 3.3.3.1. Comment Open Collector, Pull up 47 kΩ against 3.3 V Antenna Antenna connector The NAD6200 - module can be equipped with three antenna connectors. One connector is for the main antenna, second connector is for the backup antenna and third connector is for the GNSS antenna. See the following Figure 5: Antenna connectors. SPDT Main antenna connector Backup antenna connector Prepared GNSS antenna connector optional Figure 5: Antenna connectors ________________________________________________________________________________________________________________________________________ Site 26 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe Figure 6: FAKRA HF Single connector Figure 7: FAKRA HF Dual connector For detailed information see the datasheet of those connectors. The device numbers of connectors see the reference 3 and 4 at the Table 1: References. 3.3.3.2. Antenna Switching For switching between main and backup antenna a RF – switch SPDT is soldered on the PCB of the NAD6200 – module. The switch is controlled by two GPIO´s. The following Table 19 shows 4 switch combinations. Table 19: switch combinations GPIO_55 Low Low Hi Hi GPIO_56 Low Hi Low Hi Antenna None Main Backup Both Comment Whole transmission power would be reflected Outside antenna connector Inside antenna connector Mismatching The switching between different states must be synchronized with QCT software, because it is not allowed to switch between main and backup antenna during the GSM transmission pulse. The state GPIO_55 = Hi and GPIO_56 = Hi is not allowed and have to avoid via software. At the moment the main antenna is switched on by default. The main antenna is mapped to SMB connector close to outer dimension of the NAD6200 – module. ________________________________________________________________________________________________________________________________________ Site 27 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 3.3.3.3. Antenna diagnostics The diagnostic is supported for the main and backup antenna. The following states have to diagnose: a) Antenna connected b) No antenna connected c) Antenna has a short-circuit against ground d) Antenna has a short-cicuit against +Ubatt The hardware is implemented for the diagnostic for both antenna on the PCB of the NAD6200 – module. This hardware is connected to the PM8028. Main antenna is connected to MPP_08 and backup antenna is connected to MPP_07. The following expected voltage level is see at the ADC input with an external resistor R = 10 kOhm: (ADCref = 2.2 V) For For For For a) about 850 mV b) about 1150 mV c) about 390 mV d) about 1900 mV 3.3.4. Chipset MDM6200 + PM8028 The NAD Module included a Chipset from Qualcomm. This Chipset consist of the power manager PM8028 and mobile data modem MDM6200. 3.3.4.1. PM8028 The PMIC monitors and controls the power sources, detecting which sources are applied and verifying that they are within acceptable operational limits. Thermal conditions of the integrated pass transistor and its total current are monitored and reported to a state machine that coordinates PM operations. Other input power management circuits provide VDD or VBAT voltage regulation, current monitoring and over – current protection, VDD collapse protection, under – voltage lockout protection, and automated recovery from sudden momentary power loss (SMPL). On – chip voltage regulators generate 24 programmable output voltages using a combination of four switched – mode power supplies, 19 low – dropout linear regulators. 3.3.4.2. MDM6200 The MDM6200 is a mobile data modem IC. They have the following functions: Baseband functions: Processors Memory support Connectivity Air interfaces Internal BB functions Interfaces with other functions ________________________________________________________________________________________________________________________________________ Site 28 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe - General – purpose I/Os RF functions: RF transmitter (including supporting analog and LO circuits) RF receiver (including supporting analog and LO circuits) 3.3.5. Memory The NAD6200 – module has one 1 Gb NAND Flash + 512 Mb Mobile DDR SDRAM memory. For more detailed information about the memory device see the datasheet of K521H12ACI-B050. ________________________________________________________________________________________________________________________________________ Site 29 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 4. Application software Tbd ________________________________________________________________________________________________________________________________________ Site 30 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 5. Antenna characteristics 5.1. Electrical characteristics for the Antenna The end user is responsible to take care of the fulfillment of the “over the air performance” (OTA) of his end product. OTA performance will be influenced mainly by the RF routing from the module to the antenna and antenna choice. If external switches or splitters are necessary signal attenuation and degradation has to be considered. Regulatory requirements will give details on measurements and the corresponding limits. As an example 3GPP requirements are found in TS34.114 (user equipment/mobile station Over The Air antenna performance; Conformance testing). 5.2. Electrical characteristics for the Bands 5.2.1. Frequencies Table 20: Frequencies of supported WCDMA Bands for uplink Band WCDMA WCDMA WCDMA WCDMA BC1 BC2 BC5 BC8 Min 1920 1850 824 880 Typ Max 1980 1910 849 915 Unit MHz MHz MHz MHz Max 2170 1990 894 960 Unit MHz MHz MHz MHz Max 849 915 1785 1910 Unit MHz MHz MHz MHz Max 894 960 1880 1990 Unit MHz MHz MHz MHz Table 21: Frequencies of supported WCDMA Bands for downlink Band WCDMA WCDMA WCDMA WCDMA BC1 BC2 BC5 BC8 Min 2110 1930 869 925 Typ Table 22: Frequencies of supported GSM Bands (Uplink) Band GSM 850 GSM 900 GSM 1800 GSM 1900 Min 824 876 1710 1850 Typ Table 23: Frequencies of supported GSM Bands (Downlink) Band GSM 850 GSM 900 GSM 1800 GSM 1900 Min 869 921 1805 1930 Typ ________________________________________________________________________________________________________________________________________ Site 31 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 5.2.2. Power Consumption, Call Table 24: Power Consumption @ TA = +25°C, VPH_PWR = 3.8 V, P = 23 dBm Band WCDMA WCDMA WCDMA WCDMA Condition BC1 BC2 BC5 BC8 REL 99 Min Typ 584 607 620 607 Max Unit mA mA mA mA Table 25: Power Consumption @ TA = +25°C, VPH_PWR = 3.8 V, P = 10 dBm Band WCDMA WCDMA WCDMA WCDMA Condition BC1 BC2 BC5 BC8 REL 99 Min Typ 192 196 184 297 Max Unit mA mA mA mA Table 26: Power Consumption @ TA = +25°C, VPH_PWR = 3.8 V, P = 0 dBm Band WCDMA WCDMA WCDMA WCDMA Condition BC1 BC2 BC5 BC8 REL 99 Min Typ 145 147 139 143 Max Unit mA mA mA mA Table 27: Power Consumption @ TA = +25°C, VPH_PWR = 3.8 V, Single Slot Band GSM 850 GSM 900 GSM 1800 GSM 1900 Condition PCL = 5, P = 33 dBm PCL = 19, P = 5 dBm PCL = 5, P = 33 dBm PCL = 19 P = 5 dBm PCL = 0 P = 30 dBm PCL = 15 P = 0 dBm PCL = 0 P = 30 dBm PCL = 15 P = 0 dBm Min Typ Max 324 117 332 118 223 117 223 117 Unit mA mA mA mA Table 28: Idle current for GSM and WCDMA Parameter Idle current Condition GSM 900, DRX = 5, Vdd = 3.8 V Min Typ Max 2.7 Unit mA ________________________________________________________________________________________________________________________________________ Site 32 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe Idle current WCDMA BC1, DRX = 8, Vdd = 3.8 V 2.2 mA ________________________________________________________________________________________________________________________________________ Site 33 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 6. Environmental Specification 6.1. General information Storage Temperature Handling -40°C - +85°C ESD – human body rating specified with max. 2 KV 6.2. Temperature Range Table 29: Operating temperature range Range Operating temp. range Operating temp. range -30°C … +70°C -40°C … +85°C 10 3GPP spec. conform Operational Performance might slightly deviate from 3GPP spec. 10 : Due to temperature specification of the chipset, the temperature of the power manager and the temperature of the modem chip shall not exceed +85°C. ________________________________________________________________________________________________________________________________________ Site 34 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 7. Mechanical Specification Figure 8: Mechanical dimensions of the NAD6200 module Figure 9: Mechanical dimensions of the NAD6200 module (top view) ________________________________________________________________________________________________________________________________________ Site 35 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 8. Safety Recommendations according to EN60950-1 This device must be supplied by a limited power source according to EN 60950-1. The clearance and creep age distances required by the end product must be withheld when the module is installed. The cooling of the end product shall not negatively be influenced by the installation of the module. ________________________________________________________________________________________________________________________________________ Site 36 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 9. Evaluation Kit For the NAD6200 – module there is an evaluation board available. They have the following features: On beard 12 V DC power Supply or 3.8 V DC direct connected (unbuffered) USB 2.0 port type B SIM card tray 40 pin header connected to the board to board connector of the NAD6200 – module. 3 GSBI ports connected to DB9 or pin header. Figure 10: Evaluation Kit for NAD6200 module Using the evaluation board with on board 3.8 V regulator: Connect between 11 and 14 V DC to power connector 1) by using delivered cable Power up on the board with switch 2) Using the evaluation board with an external power supply: Remove Jumper 3) Switch 2) to off condition Connect external supply between 3.6 and 4.0 V DC to connector 4) Connector 4) Pin out: Pin 1: GND Pin 2: Sense GND Pin 3: Sense V+ Pin 4: V+ Note: Make sure that the external power supply is not generating spikes or hazards higher than 4.2 V. NAD6200 module gets damaged when spikes or hazards are above 4.2 V. RF Connector: ________________________________________________________________________________________________________________________________________ Site 37 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe For RF measurements use main antenna connector 5) AT Command interface: The module supports standard AT command as listed in the chapter 10.1 AT Command list. Commands are compliant to: 3GPP TS 27.007 3GPP TS 27.005 ________________________________________________________________________________________________________________________________________ Site 38 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe 10. Appendix 10.1. AT Command list Table 30: AT Command list with description Command Description AT+CMGF AT+CSCA AT+CMGS AT+CGMI AT+CGMM AT+CGMR AT+CGSN Message Format Service Centre Address Send Message Manufacturer Identification Request model identification Request revision identification Request product serial number Request international mobile subscriber identification Call mode AT+CIMI AT+CMOD AT+CHUP ATD ATA ATH AT+CBST AT+CEER AT+CVHU AT+CREG AT+COPS AT+CLCK AT+CPWD AT+CLIP AT+CLIR AT+CCWA AT+CHLD AT+CUSD AT+CLCC AT+CPOL AT+CPAS AT+CFUN AT+CPIN AT+CSQ AT+CMER AT+CSIM AT+CRSM AT+CMEE AT+CGDCONT AT+CGEQREQ AT-CGATT Comment Only one Parameter is supported by the device. Hang up call Initiate a CS or PS call or supplementary service Answer incoming CS call command Hang-up CS call command Select bearer service type Extended error report Voice hang-up control Network registration PLMN selection Facility lock Change password Calling line identification presentation Calling line identification restriction Call waiting Call related supplementary services Unstructured supplementary service data List current calls Preferred PLMN list Phone active status Set phone functionality Enter PIN Signal quality Mobile termination event reporting Generic SIM access Restricted SIM access Report mobile termination error Define PDP context Request 3G quality of service profile PS attach or detach ________________________________________________________________________________________________________________________________________ Site 39 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe Command Description AT+CGACT AT+CGPADDR AT+CGSMS ATE PDP context activate or deactivate Show PDP address Select service for MO SMS messages Character Echo ON/OFF AT+CSMS AT+CSMP AT+CSDH AT+CSCB Check Message Service support Set Text Mode Parameters Show Text Mode Parameters Select Cell Broadcast Message Types Save Settings AT+CSAS AT+CRES AT+CMGL AT+CNMA AT+CMGC AT+CMMS AT+ATV AT+ATX AT+CNMI AT+CPMS AT+CMGW AT+CMSS AT+CMGD AT+CNUM AT+CPBS AT+CPBR AT+CPBW Comment Restore Settings Only one Parameter is supported by the device. Only one Parameter is supported by the device. List messages New message acknowledgement Send Command More Messages to Send DCE response format Result code selection and call progress monitoring control New Message Indications to TE Preferred Message Storage Write Message to Memory Send Message from Storage Delete Messages Get MSISDN Select phonebook memory storage Read phonebook entries Write phonebook entry 10.2. Warning Statements FCC NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. ________________________________________________________________________________________________________________________________________ Site 40 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe (c) The provisions of paragraphs (a) and (b) of this section do not apply to digital devices exempted from the technical standards under the provisions of § 15.103. (d) For systems incorporating several digital devices, the statement shown in paragraph (a) or (b) of this section needs to be contained only in the instruction manual for the main control unit. (e) In cases where the manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the information required by this section may be included in the manual in that alternative form, provided the user can reasonably be expected to have the capability to access information in that form. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. OEM responsibility to the FCC rules and regulations The US variant without GNSS of the NAD 6200 module is labeled with its own FCC ID Number and IC ID Number. If the FCC ID is not visible when the NAD6200 module is installed inside another device, then the host device must contain the FCC ID number with the statement such as the following: “Contains Transmitter Module FCC ID: QWY-PNADA or Contains FCC ID: QWY-PNADA”. The US variant with GNSS of the NAD 6200 module is labeled with its own FCC ID Number and IC ID Number. If the FCC ID is not visible when the NAD6200 module is installed inside another device, then the host device must contain the FCC ID number with the statement such as the following: “Contains Transmitter Module FCC ID: QWY-PNADB or Contains FCC ID: QWY-PNADB”. Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by peiker acustic GmbH & Co. KG could void the user's authority to operate the equipment. RF Exposure Warning: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minium distance 20 cm between the radiator and your body. This transmitter must not be co-located or Operating in conjunction with any other antenna or transmitter. Notice: The preceding statement must be included as a Caution statement in OEM product manuals in order to alert users of FCC RF Exposure compliance. ________________________________________________________________________________________________________________________________________ Site 41 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe IC Canada This Class b digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe b est conforme à la norme NMB-003 du Canada. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. ________________________________________________________________________________________________________________________________________ Site 42 peiker acustic GmbH & Co. KG, Max-Planck-Straße 28-32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897 phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Reinhard Kromer-von Baerle, Amtsgericht Bad Homburg HRB 1369 Vorsitzender des Aufsichtsrates: Dr. Helmut Rothenberger Ein Unternehmen der peiker Firmengruppe
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 42 Language : de-DE Tagged PDF : Yes Author : Artur Rau Creator : Microsoft® Office Word 2007 Create Date : 2013:09:02 15:15:47+02:00 Modify Date : 2013:09:02 15:15:47+02:00 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools