VALEO Telematik und Akustik V1140-101-1 LTE-NAD V1140-101-1 User Manual v1140 10x 1 usermanual v13

Peiker acustic GmbH & Co. KG LTE-NAD V1140-101-1 v1140 10x 1 usermanual v13

v1140-10x-1_usermanual_v13

Download: VALEO Telematik und Akustik V1140-101-1 LTE-NAD V1140-101-1 User Manual v1140 10x 1 usermanual v13
Mirror Download [FCC.gov]VALEO Telematik und Akustik V1140-101-1 LTE-NAD V1140-101-1 User Manual v1140 10x 1 usermanual v13
Document ID2939197
Application IDUT+LI+J4Y9NDjxCqfb6RCg==
Document Descriptionv1140-10x-1_usermanual_v13
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize96.62kB (1207720 bits)
Date Submitted2016-03-23 00:00:00
Date Available2016-03-23 00:00:00
Creation Date2016-03-22 21:03:58
Document Lastmod2016-03-22 21:03:58
Document Titlev1140-10x-1_usermanual_v13
Document Author: PEIKER acustic

User manual
LTE-NAD V1140-10x-1
Peiker product IDs:
2189-140-133-00
2189-140-170-00
2189-140-174-00
2189-140-176-00
2189-140-181-00
Revision:
Date:
1.3
March 2016
Status:
Release
(V1140-103-1)
(V1140-100-1)
(V1140-104-1)
(V1140-106-1)
(V1140-101-1)
_______________________________________________________________________________________________________________ Seite 1
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
History:
Date
Revision
30.11.2015 1.0
12.01.2016 1.1
20.01.2016 1.2
22.03.2016 1.3
Name Comment
Phse
Initial document based on V1140-xxx documents
Phse
Added some missing Product IDs on the cover page
Corrected the FCC ID and IC ID of V1140-103-1 in section 8.3
Phse
Removed LTE B8 support for V1140-100-1
Phse
Updated sections 2.3 and 8.3
_______________________________________________________________________________________________________________ Seite 2
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Content
Introduction ..........................................................................................................................................4
1.1 Scope ..................................................................................................................................................4
1.2 Audience ............................................................................................................................................4
1.3 Contact information, Support .........................................................................................................4
1.4 Related Documents ..........................................................................................................................4
2 Overview ...............................................................................................................................................5
2.1 Product Variants................................................................................................................................ 5
2.2 Features .............................................................................................................................................6
2.3 Approvals ...........................................................................................................................................6
3 Overview ...............................................................................................................................................7
3.1 HW Features ......................................................................................................................................7
3.2 Connectors .........................................................................................................................................7
3.2.1 Module Signal and RF Connectors ..........................................................................................7
3.2.2 Ground and Heat Dissipation Connectors..............................................................................7
3.3 Main Interfaces .................................................................................................................................8
3.3.1 USB ..............................................................................................................................................8
3.3.2 SIM Interface .............................................................................................................................8
3.3.3 Power on.....................................................................................................................................8
3.3.4 Reset ...........................................................................................................................................8
3.3.5 GPIOs ..........................................................................................................................................9
3.3.6 GSBIs...........................................................................................................................................9
3.3.7 Module Pin-out.........................................................................................................................10
3.4 Supply Voltage ................................................................................................................................ 14
3.5 Power Consumption .......................................................................................................................14
3.8 Environmental Specification ..........................................................................................................15
3.8.1 Temperature Range ................................................................................................................15
4 Evaluation Kit .....................................................................................................................................16
5 AT Command interface .....................................................................................................................19
6 Safety Recommendations according to EN60950-1 .....................................................................21
7 List of Acronyms ................................................................................................................................ 22
8 Regulatory Certifications ..................................................................................................................23
8.1 USA (FCC) ........................................................................................................................................23
8.2 Canada (IC) .....................................................................................................................................23
8.3 OEM Responsibilities ......................................................................................................................24
_______________________________________________________________________________________________________________ Seite 3
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
1
Introduction
1.1 Scope
This document gives an overview about electrical, mechanical and functional detail of the peiker LTENAD V1140-10x-1 modules.
1.2 Audience
Information to integrate the module in other applications.
1.3 Contact information, Support
peiker acustic GmbH & Co KG
Max-Planck Street 32
D-61381 Friedrichsdorf / Ts.
Germany
http://www.peiker.de
info@peiker.de
1.4 Related Documents
None.
_______________________________________________________________________________________________________________ Seite 4
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
2
Overview
2.1 Product Variants
LTE-NAD module is available in multiple variants:
Peiker product #
2189-140-170-00 (V1140-100-1)
2189-140-181-00 (V1140-101-1)
2189-140-133-00 (V1140-103-1)
2189-140-154-00 (V1140-104-1)
2189-140-176-00 (V1140-106-1)
Module configuration
LTE EU configuration
LTE North America configuration
2G/3G EU/RoW configuration
LTE Asia Pacific configuration
2G/3G China configuration
V1140-100-1
GSM Bands
WCDMA Bands
LTE Bands
900MHz and 1800MHz
FDD1 and FDD8
eFDD3, eFDD7 and eFDD20
V1140-101-1
GSM Bands
WCDMA Bands
LTE Bands
850MHz and 1900MHz
FDD2 and FDD5
eFDD2, eFDD4, eFDD5 and eFDD17
V1140-103-1
GSM Bands
WCDMA Bands
LTE Bands
850MHz, 900MHz, 1800MHz and 1900MHz
FDD1, FDD2, FDD5, FDD6 and FDD8
No LTE support
V1140-104-1
GSM Bands
WCDMA Bands
LTE Bands
850MHz, 900MHz, 1800MHz and 1900MHz
FDD1, FDD5, FDD6 and FDD8
eFDD1, eFDD3, eFDD5, eFDD7 and eFDD19
V1140-106-1
GSM Bands
WCDMA Bands
LTE Bands
900MHz and 1800MHz
FDD1
No LTE support
_______________________________________________________________________________________________________________ Seite 5
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
2.2 Features
Features
- Same footprint and pin-out for all modules
- Voice and data calls are supported in all modules
- GSM (R99, GPRS and EDGE) for all modules
- WCDMA (R99, R5 HSDPA, R6 HSUPA and R7 HSPA+) for all modules
- WCDMA (R8 DC-HSPA+) for all modules except for V1140-101-1
- LTE (Rel.9 Cat3 FDD) for LTE capable modules
- DTM/eDTM
- eCall inband modem
- Standalone GPS/GALILEO/GLONASS, A-GPS CP (MS-Assisted and MS-Based)
- IMS/VoLTE supported by V1140-101-1 only
Data rates
- GSM: DL/UL – 14.4kbps / 14.4kbps
GPRS: Multislot class 12, DL/UL – 85.6kbps / 42.8kbps
EDGE: Multislot class 12, DL/UL – 236.8kbps / 118.4kbps
- WCDMA: DL/UL up to 384kbps
HSPA+:
Category 24 in DL using 64 QAM and Dual-Cell; Up to 42 Mbps – Not supported by
V1140-101-1
Category 14 in DL using 64 QAM; Up to 21 Mbps
Category 6 in UL using 16 QAM; Up to 5.76 Mbps
- LTE-FDD Category 3: Up to 100 Mbps in DL, up to 50 Mbps in UL
Power Classes
- LTE: All supported bands, Power Class 3
- WCDMA: All supported bands, Power Class 3
- EDGE: 850/900/1800/1900, Power Class E2
- GSM/GPRS: 850/900, Power Class 4
- GSM/GPRS: 1800/1900, Power Class 1
Dimension and Weight
- Dimensions: 31mm x 46mm x 4mm
- Weight < 10 grams
2.3 Approvals
V1140-100-1
V1140-101-1
V1140-103-1
V1140-104-1
V1140-106-1
GCF
R&TTE
Planned
Planned
Planned
Planned
Planned
Planned
PTCRB
FCC/IC
Planned
Planned
Planned
Planned
AT&T
MNO Approval
Planned
_______________________________________________________________________________________________________________ Seite 6
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
3
Overview
3.1 HW Features
Qualcomm SoC (system on chip)
MDM9215 Baseband / PMIC8018 Power management / WTR1605L
Cortex A5 Core up to 550 MHz
3 DSPs for modem and low power audio sub systems
RPM Resource and power manager
2Gb NAND Flash x16,
2Gb Low Power Mobile DDR SDRAM x32
19.2MHz clock reference
Dedicated heat sink in center area underneath the PCB
GPS/GLONASS operation, GPS antenna biasing and diagnostics
3.2 Connectors
3.2.1 Module Signal and RF Connectors
The LTE-NAD has 172 signal pins (2xAA and 2xBB) connector pads with 1.0mm pitch. The signal pads
are located close to the board edges.
There
are three antenna pads, each collocated by RF GND connectors
Main transmit and receive antenna – pin LGA_PRX_ANT
Diversity antenna for WCDMA respective MIMO antenna for LTE – pin LGA_DRX_ANT_IN
GNSS antenna for both GPS and GLONASS – pin LGA_GPS_DRX_ANT
3.2.2 Ground and Heat Dissipation Connectors
To support the usage of module under complicated thermal conditions, there are a number of large
grounded pads in the center of PCB. These pads are dedicated ground pads to transfer heat dissipation
to a carrier board.
This should be especially considered by customer designs. A reference design showing landing patterns
and PCB stack-up is available on request.
_______________________________________________________________________________________________________________ Seite 7
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
3.3 Main Interfaces
3.3.1 USB
The NAD has one USB2.0 OTG high speed (480MBit) compliant interface including the PHY. The IF
consists of 5 signals:
USB_D_P:
USB_D_M:
USB_ID:
USB_VBUS:
VREG_USB3_3V075
USB Data Plus signal
USB Data Minus signal
Master/Slave Configuration1
USB Voltage Supply
USB Voltage Output
A dynamic reconfiguration between USB-Host or USB-Device is not foreseen, the NAD can be configured
to USB-Host or USB-Device by the insertion of a resistor on the USB_ID line.
3.3.2 SIM Interface
The NADs SIM interface is compatible to 1.8V and 3V SIM Cards, the necessary voltage and level shifting
is handle by LTE-NAD automatically. The IF consists of the following signals:
VREG_USIM
USIM_CLK
USIM_DATA
USIM_RESET
The data speed on the SIM IF is up to 4 Mbps, so HW designers should take care of the length and
routing of the SIM IF to prevent potential EMC problems.
3.3.3 Power on
The signal PON_N is used switch on the NAD-Module. PON_N is pulled against VMAIN on the
LTE-NAD internally.
Due to this fact it is recommended to pull this input against GND using an open collector or
open drain output only.
3.3.4 Reset
EXT_RESIN_N is used to reset the LTE-NAD-Module, see table of LTE-NAD signal pins.
There are further reset signals available, please check.
The LTE-NAD is configured in the slave mode. For other configuration of the USB – Interface please contact
peiker acustic GmbH & Co.KG.
_______________________________________________________________________________________________________________ Seite 8
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
RES_IN is pulled against VMAIN power on the LTE-NAD internally. Therefore, it is
recommended to pull this input against GND using an open collector or open drain output only.
3.3.5 GPIOs
There are 51 GPIOs on the LTE-NAD module available. Most of them are part of the 5 GSBIs provided
in next chapter. They are used for different interfaces (see Table 1 and the following chapters). For
allocation of GPIOs/GSBIs to different configurations please contact peiker acustics GmbH & Co.KG
GPIOs and GSBIs share the same output pins and may not available when used as GSBI configuration.
The following GPIOs are not belonging to a GSBI bundle:
GPIO 47, 72, 82, 25, 28, 26, 27, 84, 80, 21, 23, 22, 24, 20, 1, 78, 79, 85, 86, 69, 0, 77, 65, 61, 68, 51, 54,
73, 48, 49, 53.
The following GPIOs are belonging to a GSBI bundle:
GPIO 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 29, 30.
3.3.6 GSBIs
Each GSBI (General Serial Bus Interface) consists of a bundle of 4 GPIOs. 5 GSBI are available.
The reference voltage is of the GSBIs is 1.8V.
Available signals on GSBI bundles at the board to board connector:
GSBI1:
GSBI2:
GSBI3:
GSBI4:
GSBI5:
GSBI1_0, GSBI1_1, GSBI1_2, GSBI1_3 (GPIO_29, 30, 2, 3)
GSBI2_0, GSBI2_1, GSBI2_2, GSBI2_3 (GPIO_4, 5, 6, 7)
GSBI3_0, GSBI3_1, GSBI3_2, GSBI3_3 (GPIO_8, 9, 10, 11)
GSBI4_0, GSBI4_1, GSBI4_2, GSBI4_3 (GPIO_12, 13, 14, 15)
GSBI5_0, GSBI5_1, GSBI5_2, GSBI5_3 (GPIO_16, 17, 18, 19)
_______________________________________________________________________________________________________________ Seite 9
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Figure 1 V1140-xxx General Serial Bus Interface GSBI interface configuration
3.3.7 Module Pin-out
Table 1
Module Pin-out
PIN
Signal
2 – 22
23
24
25
26
27
28
GND
GND
GPIO47
JTAG_TDI
JTAG_TDO
GPIO_72
JTAGTMS
JTAG_TRST_N
Direction related
to LTE-NAD
Input Power
Input Power
Input
Input
Output
IN/OUT
Input
Input
Comment
Main ground connection, Corner pad
Main ground connection
WDOG_DISABLE
JTAG Interface
JTAG Interface
JTAG Interface
JTAG Interface
_______________________________________________________________________________________________________________ Seite 10
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
PIN
Signal
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
JTAG_RTCK
GND
JTAG_TCK
JTAG_RESOUT_N
GPIO82
JTAG_PS_HOLD
EXT_RESIN_N
GND
RESOUT_N
GPIO29_ SDC2_CMD
GPIO25_ SDC2_D0
GPIO28_ SDC2_D3
GPIO30_ SDC2_CLK
GND
GPIO26_ SDC2_D1
GPIO27_ SDC2_D2
PM_GPIO4
GPIO84
GND
SDC1_CMD
SDC1_DATA0
SDC1_DATA3
SDC1_CLK
GPIO80_SDC1_DET_N
GND
SDC1_DATA2
SDC1_DATA1
GPIO21_ I2S_WS
GPIO23_ I2S_DOUT
GPIO22_ I2S_DIN
GPIO24_ I2S_MCLK
GND
GPIO20_ I2S_CLK
GPIO19_GSBI5_3
GPIO17_GSBI5_1
GPIO18_GSBI5_2
GPIO15_GSBI4_3
GND
Direction related
to LTE-NAD
Output
Input Power
Input
Input
Output
Input
Input
Input Power
Output
IN/OUT
IN/OUT
IN/OUT
Output
Input Power
IN/OUT
IN/OUT
IN/OUT
Output
Input Power
IN/OUT
IN/OUT
IN/OUT
Output
IN/OUT
Input Power
IN/OUT
IN/OUT
Output
Output
Input
Output
Input Power
Output
Output
IN/OUT
Input
Output
Input Power
67
USB_D_P
IN/OUT
68
USB_D_M
IN/OUT
69
70
GND
Input Power
Input
GPIO14_GSBI4_2
Comment
JTAG Interface
Main ground connection
JTAG Interface
JTAG Interface
NAD – Runnig, Controll signal
JTAG Interface
Input Reset for LTE-NAD module
Main ground connection
Output Reset
SD Card CMD
SD Card Data 0
SD Card Data 3
SD Card Clock
Main ground connection
SD Card Data 1
SD Card Data 2
Reset of the Codec
Main ground connection
SD Card CMD
SD Card Data 0
SD Card Data 3
SD Card Clock
Main ground connection, Corner pad
SD Card Data 2
SD Card Data 1
I²S - Word Select
I²S – Data Output
I²S - Data Input
I²S - Master Clock
Main ground connection
I²S - Clock
2 – Pin – UART TXD 3
I²C – Serial Data
2 – Pin – UART RXD 3
4 – Pin – UART TXD 1
Main ground connection
High – Speed USB Device for
communication
High – Speed USB Device for
communication
Main ground connection
4 – Pin – UART RXD 1
_______________________________________________________________________________________________________________ Seite 11
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
PIN
Signal
71
72
73
74
75
GPIO13_GSBI4_1
GPIO16_GSBI5_0
USB_ID
GPIO12_GSBI4_0
GND
Direction related
to LTE-NAD
Input
Output
Input
Output
Input Power
76
USB_VBUS
Input
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
GPIO11_GSBI3_3
GPIO10_GSBI3_2
GPIO9_GSBI3_1
GPIO8_GSBI3_0
GPIO6_ UIM2_CLK
GND
GPIO2_ UIM1_CLK
GPIO5_ UIM2_RST
GPIO7_ UIM2_DATA
GPIO4_ UIM2_DET
GND
HSIC_DATA
GND
HSIC_STROBE
GND
GPIO3_ UIM1_DATA
GPIO1_ UIM1_RST
GPIO78
GPIO79_ HSIC_RDY
GPIO85
GPIO86_
GPS_EXT_LNA_EN
GND
VREG_USB3_3V075
GND
VREG_MSME_1V8
GND
VREG_UIM2
VREG_SDC1_2V95
GND
VREG_UIM1
GND
GND
VMAIN
VMAIN
VMAIN
VMAIN
Output
Input
IN/OUT
IN/OUT
IN/OUT
Input Power
Output
IN/OUT
IN/OUT
IN/OUT
Input Power
IN/OUT
Input Power
IN/OUT
Input Power
Output
Output
IN/OUT
Output
Output
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
Comment
4 – Pin – UART Clear To Send 1
I²C - Clock
4 – Pin – UART Ready For Receive 1
Main ground connection
High – Speed USB Device for
communication
2 – Pin – UART TXD 2
2 – Pin – UART RXD 2
Main ground connection
SIM Card - Clock
Main ground connection, Corner pad
Connection to Ethernet Controller
Main ground connection
Connection to Ethernet Controller
Main ground connection
SIM Card – Data 1
SIM Card – Reset 1
Reset of Ethernet Controller
Time synchronization
IN/OUT
Input Power
Output Power
Input Power
Output Power
Input Power
Output Power
Output Power
Input Power
Output Power
Input Power
Input Power
Input Power
Input Power
Input Power
Input Power
Main ground connection
Output Power to USB
Main ground connection
Output Power
Main ground connection
Output Power to SIM Card 2
Output Power to SD Card 1
Main ground connection
Output Power to SIM Card 1
Main ground connection
Main ground connection
Main power
Main power
Main power
Main power
_______________________________________________________________________________________________________________ Seite 12
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
PIN
Signal
113
114
115
116
117
118
119
120
121
GND
GND
PON
HW-REV-RESISTOR
PM_GPIO3
GND
PM_MPP5
PM_MPP1
GND
Direction related
to LTE-NAD
Input Power
Input Power
Input
Output
IN/OUT
Input Power
Input
Input
Input Power
122
GPIO69
Output
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143 –
152
153
154 –
160
161
162 –
164
165
166
167 –
172
GPIO0_ UIM1_DET
GPIO77
GPIO65
GPIO61
PON_N
GND
GPIO68
GPIO51
GPIO54
GND
PM_MPP2
PM_GPIO2
PM_GPIO1
PM_GPIO6
GND
GPIO73
GND
GPIO48
GPIO49
GPIO53
Input
Output
Output
Input
Input
Input Power
Output
Input
Input
Input Power
Input
IN/OUT
IN/OUT
IN/OUT
Input Power
IN/OUT
Input Power
Input
Input
Input
GND
Input Power
Main ground connection
Main ground connection
Power On
Main ground connection
PM – ADC – channel
PM – ADC – channel
Main ground connection
Switch between main and back up
antenna
SIM Card – Detection 1
Reset signal of SDC2
NAD – Wake up
NAD – Update
Power On
Main ground connection
PS-3V8-Hold
BOOT_CONFIG3
BOOT_CONFIG0
Main ground connection
PM – ADC - channel
Main ground connection
Main ground connection, Corner pad
BOOT_CONFIG6
BOOT_CONFIG5
BOOT_CONFIG1
Main ground connection
Connection to the antenna switch
LGA_PRX_ANT
GND
Comment
Input Power
Main ground connection
Connection to the antenna connector
LGA_GPS_DRX_ANT
GND
Input Power
Main ground connection
LGA_DRX_ANT_IN
LGA_DRX_ANT_OUT
Input
Connection to the antenna switch
GND
Input Power
Main ground connection
_______________________________________________________________________________________________________________ Seite 13
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Note: Pins should be grounded when not used in design.
3.4 Supply Voltage
The external supply voltage is applied to LTE-NAD by 8 Pins on modules signal connectors.
PINs 109, 110, 111, 112 for VMAIN
PINs 107, 108, 113, 114 for the corresponding GND
Please note that there are further main ground connections that should be connected to ensure
proper NAD function.
TA = -40°C … +85°C
Absolute minimum/maximum supply voltages
Nominal supply voltage
Recommended supply voltage
Voltage drop @ GSM power burst (33dBm)
3.6V ~ 4.0V
3.8V
3.8V
<100mV
During Hi RF Power GSM bursts the power amplifier can draw peak currents > 2Amps at
VMAIN. The voltage drop during the GSM burst shall not exceed 100mV.
3.5 Power Consumption
TA = +25°C, VPH_PWR =3.8V
Voice
Voice
Voice
Voice
call
call
call
call
WCDMA
WCDMA
WCDMA
WCDMA
BC1
BC2
BC5
BC8
Voice call GSM850
Voice call GSM900
Voice call GSM1800
Voice call GSM1900
Standby current GSM
Standby current WCDMA
Standby current LTE
DRX = 5
DRX = 7
DRX = 7
Output Power
max. (typ. 23dBm)
~530mA
~570mA
~630mA
~580mA
Output Power
0 dBm
~145mA
~145mA
~140mA
~140mA
PCL 5 (typ. 32.5 dBm)
~260mA
~270mA
PCL 0 (typ.30.5dBm)
~165mA
~165mA
PCL 19 (typ. 5dBm)
~65mA
~65mA
PCL 15 (typ.0dBm)
~65mA
~65mA
Tbd mA
Tbd mA
_______________________________________________________________________________________________________________ Seite 14
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Output Power
Output Power
LTE data call B3
LTE data call B7
LTE data call B20
3.8 Environmental Specification
3.8.1 Temperature Range
Range
Operating temp. range
Operating temp. range
-20°C … +65°C
-40°C … +85°C
Storage temp. range
-40°C … +85°C
Note 1
3GPP spec. conform
Operational
Performance might slightly
deviate from 3GPP spec.
Note 1: Due to temperature specification of the chipset, the temperature of the power manager and the
temperature of the modem chip shall not exceed +85°C.
_______________________________________________________________________________________________________________ Seite 15
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
4
Evaluation Kit
For the NAD V1140-10x-1, there is an evaluation board available.
Features:
- On board 12V DC power supply (alternatively 3,8V DC direct connected, unbuffered).
- USB port type B
- SIM card tray
- 20 pin JTAG header for debugging
- 2 UART ports connected to DB9
- CODEC supported by I2S and I2C interfaces
Using the evaluation board with an external power supply
By default the module can be supplied by a switching regulator at 12V DC input voltage or by the module
VCC at 3.8V.
3.8V supply should be able to deliver 3.5A max. Sense contacts are for supplies which support the
corresponding feature.
Using the evaluation board with on board 3.8V regulator
For use at 3.8V simply disconnect the 12V supply and plug on 3.8V.
Note: Make sure that the external power supply is not generating spikes or
hazards higher than 4.0V. LTE-NAD Module gets damaged when spikes or
hazards above 4.0V are applied
RF Connector
For RF measurements use main antenna connector
_______________________________________________________________________________________________________________ Seite 16
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Figure 2 Evaluation Kit for V1140-10x-1.
_______________________________________________________________________________________________________________ Seite 17
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Figure 3 Power supply for Evaluation Kit for V1140-xxx.
Figure 4 SIM card and USB interfaces for Evaluation Kit for V1140-xxx.
_______________________________________________________________________________________________________________ Seite 18
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Figure 5 RF interfaces for Evaluation Kit for V1140-xxx.
AT Command interface
The modules supports standard AT command as listed below. Commands are compliant to 3GPP TS
27.007 and TS 27.005
Command
Description
AT+CMGF
AT+CSCA
AT+CMGS
AT+CGMI
AT+CGMM
AT+CGMR
AT+CGSN
Message Format
Service Centre Address
Send Message
Manufacturer Identification
Request model identification
Request revision identification
Request product serial number
Request international mobile subscriber
identification
Call mode
AT+CIMI
AT+CMOD
AT+CHUP
ATD
ATA
ATH
AT+CBST
AT+CEER
AT+CVHU
AT+CREG
AT+COPS
AT+CLCK
AT+CPWD
Comment
Only one Parameter is supported by the
device.
Hang up call
Initiate a CS or PS call or supplementary service
Answer incoming CS call command
Hangup CS call command
Select bearer service type
Extended error report
Voice hangup control
Network registration
PLMN selection
Facility lock
Change password
_______________________________________________________________________________________________________________ Seite 19
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
Command
Description
AT+CLIP
AT+CLIR
AT+CCWA
AT+CHLD
AT+CUSD
AT+CLCC
AT+CPOL
AT+CPAS
AT+CFUN
AT+CPIN
AT+CSQ
AT+CMER
AT+CSIM
AT+CRSM
AT+CMEE
AT+CGDCONT
AT+CGEQREQ
AT-CGATT
AT+CGACT
AT+CGPADDR
AT+CGSMS
ATE
Calling line identification presentation
Calling line identification restriction
Call waiting
Call related supplementary services
Unstructured supplementary service data
List current calls
Preferred PLMN list
Phone active status
Set phone functionality
Enter PIN
Signal quality
Mobile termination event reporting
Generic SIM access
Restricted SIM access
Report mobile termination error
Define PDP context
Request 3G quality of service profile
PS attach or detach
PDP context activate or deactivate
Show PDP address
Select service for MO SMS messages
Character Echo ON/OFF
AT+CSMS
AT+CSMP
AT+CSDH
AT+CSCB
Check Message Service support
Set Text Mode Parameters
Show Text Mode Parameters
Select Cell Broadcast Message Types
Save Settings
AT+CSAS
AT+CRES
AT+CMGL
AT+CNMA
AT+CMGC
AT+CMMS
AT+ATV
AT+ATX
AT+CNMI
AT+CPMS
AT+CMGW
AT+CMSS
AT+CMGD
AT+CNUM
AT+CPBS
AT+CPBR
AT+CPBW
Comment
Restore Settings
Only one Parameter is supported by the
device.
Only one Parameter is supported by the
device.
List messages
New message acknowledgement
Send Command
More Messages to Send
DCE response format
Result code selection and call progress
monitoring control
New Message Indications to TE
Preferred Message Storage
Write Message to Memory
Send Message from Storage
Delete Messages
Get MSISDN
Select phonebook memory storage
Read phonebook entries
Writephonebook entry
_______________________________________________________________________________________________________________ Seite 20
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
6
Safety Recommendations according to EN60950-1
This device must be supplied by a limited power source according to EN 60950-1.
The clearance and creepage distances required by the end product must be withheld when the
module is installed.
The cooling of the end product shall not negatively be influenced by the installation of the
module.
_______________________________________________________________________________________________________________ Seite 21
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
7
List of Acronyms
3GPP
ADC
ADN
A-GPS
3 rd Generation Partnership Project
Analog Digital Converter
Abbreviated Dialing Number
Assisted GPS
AMR
Adaptive Multi Rate
AT
AWS
BER
CLIP
CLIR
CSD
DARP
DTMF
FDN
FTP
GSM
GPIO
GPRS
GPS
HSPA
HW
LED
MO
MT
OEM
PCB
PCM
PDU
PIN
RF
RoHs
UART
USB
USIM
UMTS
WCDMA
Attention Command
Advanced Wireless Services
Bit Error Rate
Calling Line Identification Presentation
Calling Line Identification Restriction
Circuit Switch Data
Downlink Advanced Receiver Performance
Dual Tone Multi Frequency
Fixed Dialing Number
File Transfer Protocol
Global System for Mobile communication
General Purpose Input Output
General Packet Radio Service
Global Positioning System
High Speed Uplink Packet Access
Hardware
Led Emitting Diode
Mobile Originated
Mobile Terminated
Original Equipment Manufacturer
Printed Circuit Board
Pulse Code Modulation
Protocol Data Unit
Personal Identification Number
Radio Frequency
Restriction of Hazardous Substances
Universal Asynchronous Receiver and Transmitter
Universal Serial Bus
Universal Subscriber Identity Module
Universal Mobile Telecommunications System
Wideband Code Division Multiple Access
_______________________________________________________________________________________________________________ Seite 22
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
8
Regulatory Certifications
8.1 USA (FCC)
This device complies with Part 15 of the FCC rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may
cause undesired operation.
8.1.2
FCC Warnings and Notices
WARNING: The FCC requires the user to be notified that any changes or modifications
made to this device that are not expressly approved by peiker acustic GmbH & Co. KG
could void the user's authority to operate the equipment.
NOTICE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
8.2 Canada (IC)
This Class b digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe b est conforme à la norme NMB-003 du Canada.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre
le fonctionnement.
_______________________________________________________________________________________________________________ Seite 23
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
8.3 OEM Responsibilities
Antenna
The gain of the internal antenna to be used in conjunction with the ATM-01 R2-US-4G
host, including cable loss, must not exceed -1,05 dBd at 700 MHz, -0,85 dBd at 850
MHz, 1,8dBi at 1700 MHz and 2,0 dBi at 1900 MHz.
The gain of the external antenna to be used in conjunction with the ATM-01 R2-US4G host, including cable loss, must not exceed -0,34 dBd at 700 MHz, 0,64 dBd at 850
MHz, 2,4 dBi at 1700 MHz and 1,9 dBi at 1900 MHz.
The gain of the external antenna to be used in conjunction with the ATM-01 T2-US4G and TCB4G-01 T2-US-4G hosts, including cable loss, must not exceed -1,15 dBd at
700 MHz & 850 MHz and 1 dBi at 1700MHz & 1900 MHz
The systems antenna(s) must be installed such that 20 cm is maintained between the
antenna(s) and the body of the user or nearby persons.
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter. The preceding statement must be included as a Caution
statement in OEM product manuals in order to alert users of FCC RF Exposure
compliance.
Power Regulation
The host equipment must provide power regulation circuitry to ensure that the
module is supplied with stable 3.8VDC.
FCC Labeling
FCC labeling of V1140-101-1:
V1140-101-1 is labeled with its own FCC ID Number. If the FCC ID is not visible
when V1140-101-1 is installed inside another device, then the host device must
contain the FCC ID number with the statement such as the following: "Contains
Transmitter Module FCC ID: QWY-V1140-101-1" or "Contains FCC ID: QWYV1140-101-1"
FCC labeling of V1140-103-1:
V1140-103-1 is labeled with its own FCC ID Number. If the FCC ID is not visible
when V1140-103-1 is installed inside another device, then the host device must
contain the FCC ID number with the statement such as the following: "Contains
Transmitter Module FCC ID: QWY-V1140-103" or "Contains FCC ID: QWY-V1140103"
_______________________________________________________________________________________________________________ Seite 24
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe
FCC labeling of V1140-104-1:
V1140-104-1 is labeled with its own FCC ID Number. If the FCC ID is not visible
when V1140-101-1 is installed inside another device, then the host device must
contain the FCC ID number with the statement such as the following: "Contains
Transmitter Module FCC ID: QWY-V1140-104-1" or "Contains FCC ID: QWYV1140-104-1"
IC Labeling
IC labeling of V1140-101-1:
V1140-101-1 is labeled with its own IC ID Number. If the IC ID is not visible when
V1140-101-1 is installed inside another device, then the host device must contain
the IC ID number with the statement such as the following: "Contains Transmitter
Module IC 6588A-V11401011" or "Contains IC 6588A-V11401011".
IC labeling of V1140-103-1:
V1140-103-1 is labeled with its own IC ID Number. If the IC ID is not visible when
V1140-103-1 is installed inside another device, then the host device must contain
the IC ID number with the statement such as the following: "Contains Transmitter
Module IC 6588A-V1140103" or "Contains IC 6588A-V1140103".
IC labeling of V1140-104-1:
V1140-104-1 is labeled with its own IC ID Number. If the IC ID is not visible when
V1140-104-1 is installed inside another device, then the host device must contain
the IC ID number with the statement such as the following: "Contains Transmitter
Module IC 6588A-V11401041" or "Contains IC 6588A-V11401041".
_______________________________________________________________________________________________________________ Seite 25
peiker acustic GmbH & Co. KG, Max-Planck-Straße 32, D-61381 Friedrichsdorf, Amtsgericht Bad Homburg HRA 1897
phG: peiker Verwaltungs GmbH, Vorsitzender der Geschäftsführung: Andreas Peiker, Geschäftsführer: Stephan Graf von der Schulenburg, Amtsgericht Bad Homburg 1369
Vorsitzender des Aufsichtsrates: Prof. Dr. Agilolf Lamperstorfer Ein Unternehmen der peiker Firmengruppe

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 25
Language                        : en-US
Tagged PDF                      : Yes
Author                          : PEIKER acustic
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2016:03:22 21:03:58+01:00
Modify Date                     : 2016:03:22 21:03:58+01:00
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QWY-V1140-101-1

Navigation menu