VISTEON ELECTRONICS FRANCE MI Measurement Interface User Manual MI GB v4

VISTEON ELECTRONICS FRANCE Measurement Interface MI GB v4

Contents

Users Manual 2

 1  MI NOTICE             Johnson Controls Inc. 18, Chaussée Jules César BP 340 – OSNY 95526 CERGY PONTOISE CEDEX - FRANCE !xxxx0!  21837618-7 X0 GB.doc   02/03/06
 2
 3 GENERAL SAFETY PRECAUTIONS  •  Ensure you read the following instructions carefully. •  Follow all the warnings and instructions shown on the products. The International Electrical Symbols used on the device and in this notice are explained in table 1 at the end of this document. •  Disconnect the equipment from the wall socket before cleaning. Do not use cleaning fluids or aerosols. Use a slightly damp cloth for cleaning. •   This equipment must only be used with the battery and mains adapter supplied by us.   •  These instructions contain information and warnings which must be followed by the user to ensure the equipment is used and maintained safely.  •  Equipment category II: 400V overvoltage class II (IEC61010-1 electrical safety). •  Pollution level 2: non conducting pollution with occasional temporary conductivity caused by condensation (IEC61010-1 electrical safety).   IMPORTANT  To avoid the risk of electrocution: •  Live components are accessible when the equipment is open. The unit must be disconnected from the power source before any operation or repair inside the unit. •  Do not use the equipment if the unit or the connections are damaged. •  The battery access cover must be locked during use. •  Do not use the equipment in the rain.  •  Any operation other than replacement of the battery must be carried out by an after sales service technician who is qualified to do so and knows the risks involved.
 4 •  Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:  -  Reorient or relocate the receiving antenna. -  Increase the separation between the equipment and receiver. -  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -  Consult the dealer or an experienced radio/TV technician for help.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
 5  •  IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  Information to User: The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  Canada-Industry Canada(IC) Operation is subject to the following two conditions: 1) this device may not cause interference and 2) this device must accept any interference, including interference that may cause undesired operation of the device.
 6Content  1- Description ........................................................................................................ 8 1-1 Probe..........................................................................................................................8 1-2 Probe supply ..............................................................................................................8 2- Use ..................................................................................................................... 9 2-1 Connection diagram.................................................................................................10 3- technical specifications ................................................................................. 11 3-1 Equipment environment...........................................................................................11 4- Maintenance .................................................................................................... 12 4-1 battery:.....................................................................................................................12 4-1-1 Removing and refitting the battery...................................................................12 4-1-2 Recharging the battery......................................................................................13 4-2 Scrapping the battery ...............................................................................................13 5- Cleaning........................................................................................................... 13 6- Accessories..................................................................................................... 13 8- International electrical symbols.................................................................... 14 7- After sales service .......................................................................................... 14
 7
 81- Description 1-1 Probe           1-2 Probe supply  The probe may be supplied by: -  The battery of the vehicle via the MI synchronization cable -  The self contained battery -  The mains adapter only  to charge the self contained battery   Power LED  Communication LED  Self battery contained LED  Operation in progress LED  USB connector to PC  USB HUB output        Not used Power switchMains adapter connector  MI synchronization cable connector Connectors for measurements Not used
 92- Use  Warning  When working with voltages greater than 33 V RMS, 46 V peak or 70V continuous, take care as these voltages pose a risk of electrocution.  Use MI in accordance with the following instructions: •  ensure it is powered only by the internal battery, •  connect it to the central diagnostic unit using  Bluetooth mode only, •  disconnect all other USB leads, MI synchronization lead… •  cover over all connector openings using the rubber covers provided for this purpose.    Important  To avoid damage to the MI, follow the instructions below: Use the terminals and function corresponding to the measurements to be made. In ohmmeter mode, disconnect the circuit supply before checking its resistance or continuity.  Observe the temperature range for operation; do not expose the unit to heat behind a window or leave it in the cold.
 102-1 Connection diagram                Mains adapter cable USB cable  To vehicle for taking measurementTo vehicle for Power Supply  MI synchronization cable Test pins and crocodile clips  To mains
 113- technical specifications 3-1 Equipment environment  Mains adapter:  Input: 100-240V AC 1A  50-60Hz Output: 12V DC  1.67A The removable plug for the mains power distribution board is used as a breaker device for the mains power source.  This mains adapter is used only to charge the  MI self contained battery.  MI Probe:  Input: 8-16V DC   Imax 2.5A  Battery:  Type Li Ion 3.2V 2200mAH  Battery life: 1hour 30 minutes at 25°C   .  CONDITIONS FOR USE Temperature for operation with internal battery in place:  in internal battery recharge mode: from 0°C to +45°C in "measuring" mode: from -20°C to +60°C in store: from -20°C to +45°C  Temperature for operation with internal battery removed from the unit:  in "measuring" mode: from -30°C to +70°C in store: from -30°C to +80°C  Relative humidity: 0% to 90%   Operating altitude: 2,000 m  Outside of these limits, the unit is not within normal conditions of use and may not operate correctly.
 124- Maintenance Any operation other than replacement of the battery must be carried out by an after sales service technician who is qualified to do so and knows the risks involved  Only use the accessories and consumables supplied by us: measuring cables, connectors, spare battery.  4-1 Battery:  Warning Do not reverse, incinerate or mutilate battery. This can cause toxic material or gas leakage and/or explosion. 4-1-1 Removing and refitting the battery  Removal Disconnect all accessories from the MI, turn it off if it is operating, open the cover on the back of the probe and remove the battery.  Refitting Fit the battery into position, connecting it without forcing it. The battery fitting polarity MUST be observed (connector is fool proofed). Refit the cover.
 134-1-2 Recharging the battery  The battery must ONLY be recharged using the charger integrated into the MI. Just connect the probe to the mains using the mains power adapter or to the car using the MI synchronization cable (refer to the connection diagram). Make sure you observe the recharge temperatures shown in the technical specifications.  4-2 Scrapping the battery  The battery must not be thrown away. It must be returned to the manufacturer for recycling.  5- Cleaning Disconnect the power before any cleaning operation. Use a damp cloth. Do not use solvents.  6- Accessories  Battery Type Li Ion 3.2V 2200mAH  218368073 MI synchronization cable  218365548 Adaptater AC/DC  218365598 Mains adapter cable  xxxxx USB lead  218365556 Measurement leads red, black & blue   218374109 Tests pin red, black & blue  218374120 Crocodile clamps red, black & blue   218374117
 148- International electrical symbols   DC (Direct current)  AC (Alternating current)  AC or DC  Earth ground  Warning, refer to the notice for information  Warning against electrical choc   Double insulated  7- After sales service In the event of any problems, please contact your Johnson Controls Inc. representative.      Johnson Controls Inc. Service après-vente 1, Avenue Pierre-Gilles de Gennes Z.I. des Ajeux 72400 La Ferté-Bernard  France  Tel.:   +33 2 43 60 43 60 Fax:   +33 2 43 60 43 61