Vanguard Managed Solutions Bhdv34Pb Users Manual 106516 01
eb6eafa1-6bf6-caa4-bdbb-90361f23ff69 Vanguard Managed Solutions Outdoor Fireplace BHDV34PB User Guide |
2015-02-03
: Vanguard-Managed-Solutions Vanguard-Managed-Solutions-Bhdv34Pb-Users-Manual-457485 vanguard-managed-solutions-bhdv34pb-users-manual-457485 vanguard-managed-solutions pdf
Open the PDF directly: View PDF .
Page Count: 38
Download | |
Open PDF In Browser | View PDF |
® DIRECT-VENT FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL NATURAL GAS MODEL BHDV34NB PROPANE/LP GAS MODEL BHDV34PB WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier. — Installation and service must be performed by a qualified installer, service agency, or the gas supplier. — This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. Save this manual for future reference. BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® SAFETY INFORMATION WARNINGS IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosions, electrical shock, and carbon monoxide poisoning. 1. 2. 3. DANGER: Carbon monoxide poisoning may lead to death! This fireplace is a vented product. This fireplace will not produce any gas leakage into your home if properly installed. This fireplace must be properly installed by a qualified service person. The glass door must be properly seated and sealed. If this unit is not properly installed by a qualified service person with glass door properly seated and sealed, gas leakage can occur. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace. WARNING: Any change to this fireplace or its controls can be dangerous. 4. 5. 6. 7. 8. 9. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use any phone in your building • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions • if you cannot reach you gas supplier, call the fire department. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 42" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching. Carefully supervise young children when they are in the room with fireplace. Do not modify this fireplace under any circumstances. Any parts removed for servicing must be replaced prior to operating fireplace. Turn fireplace off and let cool before servicing, installing, or repairing. Only a qualified service person should install, service, or repair this fireplace. Have fireplace inspected annually by a qualified service person. You must keep control compartments, burners, and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, pet hair, etc. Turn off the gas valve and pilot light before cleaning fireplace. 2 10. Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 28. 11. Keep the area around your fireplace clear of combustible materials, gasoline, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate. 14. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANS/NFPA 70, or the Canadian Electrical Code, CSA C22.1. 15. Do not obstruct the flow of combustion and ventilation air in any way. Provide adequate clearances around air openings into the combustion chamber along with adequate accessibility clearance for servicing and proper operation. 16. Do not install fireplace directly on carpeting, vinyl tile, or any combustible material other than wood. The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace. 17. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit. 18. Do not operate fireplace if any log is broken. 19. Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this fireplace. 20. Do not operate fireplace with glass door removed, cracked, or broken. 106516 OWNER’S MANUAL PRODUCT IDENTIFICATION Top Louver Panel LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANS Z223.1, also known as NFPA 54* (USA) or the current CAN/CGA-B149[.1 or .2] Installation Codes (Canada). Vent Opening Standoff Nailing Flange *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 Glass Door Assembly Log Set Lower Louver Panel Pilot Assembly Burner Piezo Ignitor National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 PRODUCT FEATURES OPERATION Valve Grate Assembly Glowing Embers Lava Rock Blower Adjustment (Optional Installation) Figure 1 - Vanguard Direct-Vent Fireplace BHDV Series This direct-vent fireplace is clean burning and vents easily through outside walls or vertically using outside air for combustion. Heat is generated by both realistic flames and glowing embers. When used without the blower accessory, the fireplace requires no electricity making it ideal for emergency backup heat. PIEZO IGNITOR This fireplace has a piezo ignitor. This system requires no matches, batteries, or other sources to light fireplace. GLOSSARY OF TERMS Chase - A boxlike enclosure to protect venting from the elements when the venting run is on the outside of a structure. Mastic - A pliable sealant for use around the vent terminal. Snorkel Termination - A box that raises the horizontal termination above ground level clearances. Vent Terminal - Mounted on an outside wall or roof to separate the inlet and outlet of the vent system and protect it from weather. Vinyl Siding Standoff - A metal box that separates the vent cap from vinyl siding. Wall Thimble/Firestop - A metal plate used to secure the vent pipe when it passes through a wall or ceiling. 106516 3 BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® PRE-INSTALLATION PREPARATION LOCATION AND SPACE REQUIREMENTS Determine the safest and most efficient location for your Vanguard direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common locations. Read all venting information in this manual. Be aware of all restrictions and precautions before deciding the exact location for your fireplace. When deciding the location of your fireplace, follow these rules: 1. Do not connect this fireplace to a chimney flue serving a separate solid-fuel burning fireplace or appliance. 2. Due to high temperatures, do not locate this fireplace in high traffic areas or near furniture or draperies. 3. Proper clearances must be maintained. 4. If your fireplace is to be installed directly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3. CLEARANCES Minimum clearances to combustibles for the fireplace are as follows: Back, and sides Perpendicular walls Floor Ceiling to louver opening Front Top of Standoffs Must maintain a minimum 1" clearance to combustibles 0"/mm 6" (152mm) 0"/mm 42" (1067mm) 36" (914mm) 0"/mm See General Venting on page 5 for specific venting clearances. 34" FRAMING AND FINISHING Figures 4 and 5 show typical framing of this fireplace. Figure 6 on page 5 shows framing for corner installation. All minimum clearances must be met. Do not install fireplace directly on carpeting, vinyl tile, or any combustible material other than wood. The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace. See Accessories on pages 34 and 35 for mantel kits available for this fireplace. If you are using a separate combustible mantel piece, refer to Figure 7 on page 5 for proper installation height. You can install noncombustible mantels at any height above the fireplace. Note: Noncombustible mantels may discolor! 20" 5/8" for drywall facing Figure 5 - Framing Clearances for Typical Fireplace Installation Flush with a wall Through exterior wall enclosed in a chase Corner installation 34 1/4" Figure 2 - Common Fireplace Locations RW D 34 3/4" FW 20" Vertical Termination 19" Horizontal Termination Fireplace size D x FW x RW 34" 18 1/2" 34 3/8" 14" Figure 3 - Fireplace Bottom Dimensions Figure 4 - Framing Clearances for Installation Against an Exterior Wall 4 106516 OWNER’S MANUAL PRE-INSTALLATION PREPARATION GENERAL VENTING These models are approved for use with Simpson Dura-Vent 6 5/8" direct-vent pipe components and terminations as well as both flex and rigid Vanguard vent components. Continued 13" 9 1/4" 41" 29" 12 5/8" 34 3/8" Nailing Tabs 35 1/16" 58" Figure 6 - Framing Clearances for Corner Installation 1 2 Note: There must be a minimum clearance of 18" above top of louver opening when installing a television or entertainment center above the fireplace. 3 A 4 B Wall 5 C 6 D E 7 F G LOCATION OF VENT TERMINATION Top of Louver Opening Ref. Mantel Depth Ref. Mantel from Top of Louver Opening 1 14" (356mm) A 16" (406mm) 2 12" (305mm) B 14" (356mm) 3 10" (254mm) C 12" (305mm) 4 8" (203mm) D 10" (254mm) 5 6" (152mm) E 8" (203mm) 6 4" (101mm) F 6" (152mm) 7 2" (51mm) G 4" (101mm) Your fireplace is approved to be vented either through the side wall, or vertically using the following guidelines: • Only use Vanguard or Simpson DuraVent GS venting components or kits specifically approved for this fireplace. • Minimum clearance between vent pipes and combustible materials is 1" (25 mm), except where stated otherwise. • Combustible material may be flush with the top front of fireplace with a maximum thickness of 3/4". • Do not recess venting terminals into a wall or siding. • You must install a vinyl siding standoff if vinyl siding is covering the exterior wall. • Install horizontal venting with a 1/4" rise for every 12" of run toward the termination. • You may paint the vent terminal with 450ºF (232ºC) heat-resistant paint to coordinate with the exterior finish. • There must not be any obstruction such as bushes, garden sheds, fences, decks, or utility buildings within 24" from the front of the termination cap. • Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termination area. When locating vent termination, it is important to observe the minimum clearances shown in Figure 8, page 6. You will avoid extra framing by positioning your fireplace against an already existing framing member. The sides of the fireplace may be positioned directly against combustible walls. *Check with local codes or with the current CAN/CGA B149 [.1 or .2] Installation Codes for Canada or the USA Installations follow the current National Fuel Gas Code, ANS Z223.1, also known as NFPA 54. Figure 7 - Clearances for Combustible Mantels Continued 106516 5 BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® GENERAL VENTING Continued N N D H V L E B C Fixed Closed F B Openable Fixed Closed V Openable V I V G B V B B J X V G G M A V K X V A V TERMINATION CAP A = clearance above grade, veranda, porch, deck, or balcony [*12 inches (305mm) minimum] B = clearance to window or door that may be opened [12 inches (305mm) minimum] C = clearance to permanently closed window [minimum 12 inches (305mm) recommended to prevent condensation on window] D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (610mm) from the center-line of the terminal [18 inches (457mm) minimum] E = clearance to unventilated soffit [12 inches (305mm) minimum] F = clearance to outside corner (see below) G = clearance to inside corner (see below) H = *not to be installed above a meter/regulator assembly within 36 inches (914mm) horizontally from the center-line of the regulator I = J = K = L = M= N = G GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) clearance to service regulator vent outlet [*72 inches (1829mm) minimum] clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12 inches (305mm) minimum] clearance to a mechanical air supply inlet [*72 inches (1829mm) minimum] † clearance above paved side-walk or a paved driveway located on public property [*84 inches (2133mm) minimum] clearance under veranda, porch, deck [*12 inches (305mm) minimum ‡] clearance above a roof shall extend a minimum of 24 inches (610mm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (457mm) X AIR SUPPLY INLET † vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* ‡ only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/SGA B149 (.1 or .2) Installation Codes (1991) for Canada or for U.S.A. installation follow the current National Fuel Gas Code, ANS Z223.1 Note: Local codes or regulations may require different clearances Termination Clearances for Buildings with Combustible and Noncombustible Exteriors Inside Corner Outside Corner Recessed Location D C A C A = 6" (152mm) E V V V B = 6" (152mm) B Balcony with No Side Wall Balcony with Perpendicular Side Wall C = Maximum depth of 48" (1219mm) for recessed location D = Minimum width for back wall of recessed location Combustible - 38" (965mm) Noncombustible - 24" (610mm) E = Clearance from corner in recessed locationCombustible - 6" (152mm) Noncombustible - 2" (51mm) H G V V J G = Combustible 24" (610mm) Noncombustible 18" (457mm) Combustible & Noncombustible H = 24" (610mm) J = 20" (508mm) Figure 8 - Minimum Clearances for Vent Terminations 6 106516 OWNER’S MANUAL VENTING INSTALLATION WARNING: Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life. WARNING: Seal all vent connections. Seal only the outer pipe connections with high temperature silicone (600°F/316° C). Before joining elbows and pipes, apply a bead of high temperature silicone sealant (GE RTV 106/Loctite RTV 81585) to the male end of the elbow or pipe. High temperature silicone must also be used to re-seal any connections after maintenance to venting system. NOTICE: Failure to follow these instructions will void the warranty. INSTALLATION PRECAUTIONS Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this fireplace manual and vent kit instructions. • Installation of any component part not manufactured or approved by DESA International • Installation other than as instructed by these instructions WARNING: This gas fireplace and vent assembly must be vented directly to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate vent system. Do not use common vent systems. WARNING: Horizontal sections of this vent system require a minimum clearance of 2" from the top of the pipe and 1" minimum to the sides and bottom. 1 1/2" clearance is required where the termination penetrates a combustible wall. Vertical sections of this system require a minimum of 1" clearance to combustible materials on all sides of the pipe. INSTALLATION PLANNING There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness. Only a qualified service person should install venting system. The installer must follow these safety rules: • Wear gloves and safety glasses for protection • Use extreme caution when using ladders or when on roof tops • Be aware of electrical wiring locations in walls and ceilings For Horizontal Termination: Select the amount of vertical rise desired. The horizontal run of venting must have 1/4" rise for every 12" of run towards the termination. The following actions will void the warranty on your venting system: • Installation of any damaged venting component • Unauthorized modification of the venting system You may use one or two 90° elbows in this vent configuration. See Horizontal Termination Configurations on pages 10 and 11. 106516 WARNING: Never run the vent downward as this may cause excessive temperatures which could cause a fire. For Vertical Termination: Measure the dis- tance from the fireplace flue outlet to the ceiling. Add the ceiling thickness, the verti7 cal rise in an attic or second story, and allow for sufficient vent height above the roofline. You may use one or two 90° elbows in this vent configuration. See Vertical Termination Configurations on pages 13 and 14. Note: You may use two 45° elbows in place of a 90° elbow. You must follow rise to run ratios when using 45° elbows. For two-story applications, firestops are required at each floor level. If an offset is needed in the attic, additional pipe and elbows will be required. You may use a chase with a vent termination with exposed pipe on the exterior of the house. See Installing Vent System in a Chase, below. Your Vanguard direct-vent fireplace has been tested for a minimum 3' rise with a maximum 10" wall thickness. The maximum horizontal run is 20' with 8' vertical rise (see Installation for Horizontal Termination, page 8). The maximum vertical run is 30' (see Installation for Vertical Termination, page 12). It is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust. Certain limitations apply to vent configurations and must be strictly followed. Installing Vent System in a Chase A chase is a vertical boxlike structure built to enclose venting that runs along the outside of a building. A chase is not required for such venting. NOTICE: Treatment of firestops and construction of the chase may vary from building type to building type. These instructions are not substitutes for the requirements of local building codes. You must follow all local building codes. Note: When installing in a chase, you should insulate the chase as you would the outside walls of your home. This is especially important in cold climates. Minimum clearance between vent pipes and combustible materials such as insulation is 1". After framing the chase (see Framing and Finishing on pages 4 and 5) install the vent system by following the installation instructions. Continued BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® VENTING INSTALLATION Snorkel Continued INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed. 12" Minimum To Ground Level ,,,,, ,,,,, ,,,,, ,,,,, WARNING: Do not recess vent terminal into a wall or siding. 2. Snorkel terminations are available for terminations requiring a vertical rise on the exterior of the building (see Figures 9 and 10). Snorkel kit SVK is also available (see page 15). Follow the same installation procedures used for standard horizontal terminations. If installing the snorkel termination below grade (basement applications), you must provide proper drainage to prevent water from entering the snorkel termination (see Figure 10). Do not back fill around the snorkel termination. Rigid vent pipes and fittings have special twist-lock connections. Assemble the desired combination of pipe and elbows to the appliance adaptor with pipe seams oriented towards the wall or floor. Twist-lock Procedure: The female ends of the pipes and fittings have four locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes and fittings. (All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 7.) Push the pipe sections together and twist one section clockwise approximately one-quarter turn until the sections are fully locked. See Figure 11, page 9. Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose. Flexible vent pipe must be installed with spacer springs every 12". See Figure 11, page 9. All connections must be clamped tightly and sealed with high temperature silicone sealant as specified in the second warning statement on page 7. Figure 9 - Snorkel Termination Snorkel 12" Minimum To Ground Level Adequate drainage ,,,,,,,,,,,,,, ,,,,,,,,,,,,,, ,,,,,,,,,,,,,, ,,,,,,,,,,,,,, ,,,,,,,,,,,,,, ,,,,,,,,,,,,,, ,,,,,,,,,,,,,, Figure 10 - Snorkel Termination with Drainage Pipe 8 106516 OWNER’S MANUAL VENTING INSTALLATION 4. Continued 3. Attach vent pipe assembly to the fireplace. Set fireplace in front of it’s permanent location to insure minimum clearances. Mark the wall for a 10" square hole (for noncombustible material such as masonry block or concrete, a 7 1/2" diameter hole is acceptable). See Figure 12. The center of the hole should line up with the centerline of the horizontal rigid vent pipe. Cut a 10"x10" (254mm x 254mm) square hole through combustible exterior wall (7 1/2" [190mm] diameter hole if noncombustible). Frame as necessary (see Figure 12). WARNING: Do not recess vent termination in to any wall. This will cause a fire hazard. 4" Clamp Female Locking Lugs 7" Clamp Spacer Spring 4" Flex Pipe Male Slots Apply a bead of non-hardening mastic around the outside edge of the vent cap. Position the vent cap in the center of the 7 1/2" or 10" hole on the exterior wall with the arrow on the vent cap pointing up. Insure proper clearance of 1" to combustibles is maintained. Attach the vent cap with four wood screws supplied (see Figure 13). Note: Replace the wood screws with appropriate fasteners for stucco, brick, concrete, or other types of siding. 5. For vinyl siding use vinyl siding standoffs between vent cap and exterior wall. The vinyl siding standoff prevents excessive heat from melting the vinyl siding material. Bolt the vent cap to the standoff. Apply non-hardening mastic around outside edge of the standoff instead of the vent cap assembly. Use wood screws provided to attach the standoff. See Figure 14. Slide the wall thimble over the vent pipe before connecting the horizontal run to the vent cap (see Figure 15). 7" Flex Pipe 6. 7. Carefully move the fireplace with vent assembly attached toward the wall and insert the vent pipe into the horizontal termination. The pipe overlap should be a minimum of 1 1/4". Apply silicone to the outer pipe connection. Fasten all vent connections with screws provided. Refer to Fireplace Installation on page 16 for instructions on securing unit to framing or floor. Slide the wall thimble against the interior wall surface and attach with screws provided (see Figure 15). Cut Vinyl Siding Away to Fit Standoff Wood Screw Standoff UP Nut Bolt Apply Mastic to All Four Sides Vent Cap Figure 14 - Installing Vinyl Siding Standoff Apply Mastic to All Four Sides Rigid Vent Pipe Flexible Vent Pipe Figure 11 - Vent Pipe Connections Interior Wall Surface Vent Opening Combustible Wall Wall Thimble UP 10" (254mm) Wood Screw 10" (254mm) Vent Opening Noncombustible Wall Vent Cap (Framing Detail) Figure 13 - Installing Horizontal Vent Cap Vent Cap (Horizontal Termination) Screw Horizontal Vent Pipe Figure 15 - Connecting Vent Cap with Horizontal Vent Pipe 7 1/2" (190mm) Figure 12 - Vent Opening Requirements Continued 106516 9 BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® VENTING INSTALLATION Continued Horizontal Venting UP Horizontal Termination Configurations Figures 16 through 20 show different configurations for venting with horizontal termination. Each figure includes a chart with vertical minimum/maximum and horizontal maximum dimensions which must be met. Seal all connections with high temperature silicone sealant (outer pipe only) as specified in the second warning statement on page 7. All horizontal terminations require 1/4" rise per 12" of horizontal run. Vertical (V) Horizontal (H) 44" min. 29" max. (30° and 90° only, no vertical pipe) 55" min. 41" max. (30° elbow, 1' vertical pipe, 90° elbow) 67" min. 79" min. 96" min. 60" max. 84" max. 20' max. Note: This configuration for use with corner installation. BVK Vent Kit Shown Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One 90° Elbow Horizontal Venting UP BGFVK Vent Kit Shown (recommended for use with cabinet mantels) Horizontal Venting Vertical (V) Horizontal (H) 37" min. 10" max. See information in Figure 17 for Vertical(V) and Horizontal(H) maximums and minimums. The same amounts apply for flexible venting. UP Note: Figure 16 applies to rigid venting only. BFGFVK and FGFVK Vent Kits Shown Figure 16 - Horizontal Termination Configuration for Rigid Venting Figure 18 - Horizontal Termination Using Flexible Venting 10 106516 OWNER’S MANUAL VENTING INSTALLATION Continued Venting with Two 90° Elbows Vertical (V) Horizontal (H1) Horizontal (H1) + Horizontal (H2) 5' min. 6' min. 7' min. 8' min. 2' max. 4' max. 6' max. 8' min. 6' max. 12' max. 18' max. 20' max. 20' max. 8' max. 20' max. UP Figure 19 - Horizontal Termination Configuration for Rigid Venting Using Two 90° Elbows Venting with Two 90° Elbows Vertical (V) Horizontal (H1) + Horizontal (H2) 5' min. 6' min. 7' min. 8' min. 6' max. 12' max. 18' max. 20' max. 20' max. 20' max. Figure 20 - Horizontal Termination Configuration for Rigid Venting Using Two 90° Elbows with Termination at 90° with Fireplace Continued 106516 11 BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® VENTING INSTALLATION Flat Ceiling Installation 1. Continued INSTALLATION FOR VERTICAL TERMINATION NOTICE: Use rigid pipe only. Flex venting is not to be used with a vertical termination. 1. 2. Determine the route your vertical venting will take. If ceiling joists, roof rafters, or other framing will obstruct the venting system, consider an offset (see Figure 21) to avoid cutting load bearing members. Note: Pay special attention to these installation instructions for required clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, etc. Do not pack air spaces with insulation. Also note maximum vertical rise of the venting system and any maximum horizontal offset limitations. Offsets must fall within the parameters shown in Figure 8 on page 6. Set the fireplace in desired location. Drop a plumb line down from the ceiling to the position of the fireplace exit flue. Mark the center point where the vent will penetrate the ceiling. Drill a small locating hole at this point. Drop a plumb line from the inside of the roof to the locating hole in the ceiling. Mark the center point where the vent will penetrate the roof. Drill a small locating hole at this point. 2. 3. Cut a 10" square hole in the ceiling using the locating hole as a center point. The opening should be framed to 10"x10" (254mm x 254mm) inside dimensions, as shown in Figure 12 on page 9 using framing lumber the same size as the ceiling joists. If the area above the ceiling is an insulated ceiling or a room, nail firestop from the top side. This prevents loose insulation from falling into the required clearance space. Otherwise, install firestop below the framed hole. The firestop should be installed with no less than three nails per side (see Figure 22). Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 7. Be sure all pipe and elbow connections are fully twistlocked (see Figure 11, page 9). Cut a hole in the roof using the locating hole as a center point. (Cover any exposed open vent pipes before cutting hole in roof.) The 10"x10" hole must be measured on the horizontal; actual length may be larger depending on the pitch of the roof. There must be a 1" clearance from the vent pipe to combustible materials. Frame the opening as shown in Figure 12 on page 9. If area above is a room, install firestop above framed hole. Roof Flashing 4. Connect a section of pipe and extend up through the hole. Note: If an offset is needed to avoid obstructions, you must support the vent pipe every 3 feet. Use wall straps for this purpose (see Figure 21). Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers less restriction to the flow of the flue gases and intake air. 5. Place the flashing over the pipe section(s) extending through the roof. Secure the base of the flashing to the roof and framing with roofing nails. Be sure roofing material overlaps the top edge of the flashing as shown in Figure 21. There must be a 1" clearance from the vent pipe to combustible materials. 6. Continue to add pipe sections until the height of the vent cap meets the minimum building code requirements described in Figure 8 on page 6. Note: You must increase vent height for steep roof pitches. Nearby trees, adjoining rooflines, steep pitched roofs, and other similar factors may cause poor draft or down-drafting in high winds. Increasing the vent height may solve this problem. 7. Twist-lock the vent cap onto the last section of vent pipe and seal outer pipe connection with high temperature silicone sealant as specified in the second warning statement on page 7. Note: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclosure with standard construction material. Make sure and meet the minimum allowable clearances to combustibles. Do not fill any of the required air spaces with insulation. Cathedral Ceiling Installation 1. Wall Strap 45° Elbow If area above is not a room, install firestop below framed hole. 2. Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box. Mark the outline of the cathedral ceiling support box on the roof sheathing using the locating hole as a center point. Cut the hole 1/8" larger than the support box outline (see Figure 23, page 13). Ceiling Firestop Figure 21 - Offset with Wall Strap and 45° Elbows Figure 22 - Installing Firestop 12 106516 OWNER’S MANUAL VENTING INSTALLATION Continued 3. 4. 5. Vertical Termination Configurations Figures 25 through 28 show four different configurations for vertical termination. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 7. Lower the support box through the hole in the roof until the bottom of the box extends at least 2" below the ceiling (see Figure 23). Align the support box vertically and horizontally using a level. Temporarily tack the support box in place through the inside walls and into the roof sheathing. Using tin snips, cut the support box from the top corners down to the roofline and fold the resulting flaps over the roof sheathing (see Figure 24). Apply a bead of non-hardening mastic around the top edges of the support box to make a seal between the box and the roof. Nail in place with roofing nails. Remove any combustible material that might be inside of the support box. Complete the cathedral ceiling installation by following the same procedures outlined in steps 2 through 7 for Flat Ceiling Installation, page 12. Venting with Two 90° Elbows Vertical (V) Horizontal (H1) + Horizontal (H2) 5' min. 6' min. 7' min. 8' min. 2' max. 4' max. 6' max. 8' max. 20' max. 8' max. Note: Install restrictor into 4" collar of fireplace as shown. Level Cathedral ceiling support box 2" minimum below finished ceiling Figure 25 - Vertical Rigid Venting Configuration Using Two 90° Elbows with Two Horizontal Runs Venting with One 90° Elbow Note: Install restrictor into 4" collar of fireplace as shown. Cut hole 1/8" larger than support box when projected onto roofline Figure 23 - Cathedral Ceiling Support Box Installation Non-hardening Mastic under all edges of support box before nailing Figure 24 - Installed Cathedral Ceiling Support Box 106516 Vertical (V) Horizontal (H) 5' min. 6' min. 7' min. 8' min. 2' max. 4' max. 6' max. 8' max. 20' max. 8' max. Figure 26 - Vertical Rigid Venting Configuration Using One 90° Elbow 13 Continued BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® VENTING INSTALLATION Continued Note: Install restrictor into 4" collar of fireplace as shown. Note: Install restrictor into 4" collar of fireplace as shown. RVF Kit Shown Vertical Venting Venting with Two 90° Elbows Vertical (V1) Horizontal (H) 5' min. 6' min. 7' min. 8' min. 6' max. 12' max. 18' max. 20' max. V = 40' max. Figure 28 - Vertical Rigid Venting Configuration With No Horizontal Run Note: Vertical (V1) + Vertical (V2) = 20' max. Figure 27 - Vertical Rigid Venting Configuration Using Two 90° Elbows 14 106516 OWNER’S MANUAL VENTING INSTALLATION Continued HIGH ALTITUDE INSTALLATION Your Vanguard direct-vent fireplace has been AGA tested and approved for elevations from 0-2000 feet and CGA certified for elevations from 0-4500 feet. When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification. When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities. Consult your local gas company to help determine the proper orifice for your location. For assistance with any high altitude installation contact DESA International’s Technical Service Department at 1-800-DESALOG (1-800-337-2564). PARTS LISTS FOR VENTING KITS AND COMPONENTS Vanguard Rigid Venting Number Description BGFVK CVK BVK SVK 106516 Basic Ground Floor Rigid Vent Kit Includes: 7" x 60° Elbow, Extended Adjustable Horizontal Termination, Wall Thimble and 14 Screws Corner Vent Kit Includes: 7" x 30º Elbow, 7" x 90º Elbow, 7" Adjustable Galvanized Pipe (7-12"), 6" Pipe, Wall Thimble, Horizontal Termination, RTV Silicone and 20 Screws Basement Rigid Vent Kit Includes: 7" x 30° Elbow, 7" x 4' Galvanized Pipe, 7" x 90° Elbow, 7" Adjustable Galvanized Pipe (7-12"), Wall Thimble, Horizontal Termination, RTV Silicone and 20 Screws Snorkel Rigid Vent Kit Includes: 7" x 30° Elbow, 7" x 4' Galvanized Pipe, 7" x 90° Elbow, 7" Adjustable Galvanized Pipe (7-12"), Wall Thimble, 36" Snorkel Termination, RTV Silicone and 28 Screws Vanguard Rigid Venting (Cont.) Vanguard Flexible Venting (Cont.) Number Description Number Description RVF FGFVK Flex Ground Floor Vent Kit Includes: Flex Adapter, 7" x 4' Flexible Pipe, 4" x 4' Flexible Pipe, Wall Thimble, Horizontal Termination, (4) Spacer Springs, (2) 4" Hose Clamps, (2) 7" Hose Clamps, RTV Silicone, and 10 Screws D1040 7" x 25' Coaxial Flex Pipe with Spacer Springs D3080 Rectangular Horizontal Flex Termination Cap Flex Connector (6 pcs.) Flex Wall Thimble (6 pcs.) 4" Hose Clamp (6 pcs.) 7" Hose Clamp (6 pcs.) D1000 D1010 D1020 D1030 D1050 D2000 D2010 D2020 D2030 D3000 D3010 D3020 D3040 D3050 D3060 D3070 D3071 D3090 D4000 D4010 D5000 Roof Rigid Vent Kit Includes: Flue Restrictor, Storm Collar, 7" x 30° Elbow, 7" x 4' Galvanized Pipe, 7" x 2' Galvanized Pipe, 7" Adjustable Galvanized Pipe (7-12"), Firestop Support, Roof Flashing, RTV Silicone, Vertical Termination, and 26 screws 7" x 12" Galvanized Coaxial Pipe (6 pcs.) 7" x 24" Galvanized Coaxial Pipe (6 pcs.) 7" x 48" Galvanized Coaxial Pipe (6 pcs.) 7" Adjustable (7-12") Galvanized Coaxial Pipe (6 pcs.) 7" x 6" Galvanized Coaxial Pipe (6 pcs.) 7" x 90° Elbow (6 pcs.) 7" x 45° Elbow (6 pcs.) 7" x 30° Elbow (6 pcs.) 7" x 60° Elbow (6 pcs.) Wall Strap/Offset Support (6 pcs.) Storm Collar (6 pcs.) Wall Thimble (6 pcs.) Vertical Vent Termination Cap Vertical Restrictor (6 pcs.) Ceiling Firestop/Support (6 pcs.) Rectangular Horizontal Rigid Vent Termination Cap Adjustable Horizontal Rigid Vent Termination Cap Cathedral Ceiling Support Box Roof Flashing 6/12-9/12 Roof Flashing 9/12-12/12 Wood/Vinyl Siding Standoff (6 pcs.) Vanguard Flexible Venting Number Description BFGFVK Basic Flex Ground Floor Vent Kit Includes: Flex Adapter, 7" x 2' Flexible Pipe, 4" x 2' Flexible Pipe, Wall Thimble, Horizontal Termination, (2) Spacer Springs, (2) 4" Hose Clamps, (2) 7" Hose Clamps, and 10 Screws 15 D4020 D4030 D4040 D4050 SIMPSON DURA-VENT GS 4" x 6 5/8 " Number Description Available from DESA International: SD2040 Simpson Dura-Vent GS 30° Elbow (6 pcs.) SD2050 Simpson Dura-Vent GS 60° Elbow (6 pcs.) Available from Simpson Dura-Vent only: 902 903 904 906 907 908 911 940 941 943 943S 945 950 953 963 981 984 988 990 991 7" x 48" Pipe 7" x 36" Pipe 7" x 24" Pipe 7" x 12" Pipe 7" x 9" Pipe 7" x 6" Pipe 7" Adjustable (11"-14 5/8") Pipe Wall Thimble Cathedral Ceiling Support Box Roof Flashing 0/12-6/12 Roof Flashing 7/12-12/12 7" x 45° Elbow Vinyl Siding Standoff Storm Collar Ceiling Firestop 36" Snorkel Termination Horizontal Termination Vent Cap Wall Strap 7" x 90° Elbow Vertical High Wind Termination BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® FIREPLACE INSTALLATION NOTICE: This fireplace is intended for use as supplemental heat. Use this fireplace along with your primary heating system. Do not install this fireplace as your primary heat source. If you have a central heating system, you may run system's circulating blower while using fireplace. This will help circulate the heat throughout the house. In the event of a power outage, you can use this fireplace as a heat source. WARNING: A qualified service person must install fireplace. Follow all local codes. CAUTION: This fireplace creates warm air currents. These currents move heat to wall surfaces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating fireplace where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls. Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing material. See framing details on page 4. CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace according to your gas type. INSTALLING OPTIONAL BLOWER ACCESSORY NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas supply and disconnect heater from gas supply. Contact a qualified service person to do this. Attaching Thermal Switch to DA3610TA ThermostaticallyControlled Blower When installing the DA3610TA thermostatically-controlled blower accessory, you must first secure the thermal switch to the blower. 1. Remove the two hex head screws on the blower assembly as shown in Figure 29. 2. Place the green wire between the bottom hole on the thermal switch bracket and the bottom hole on the blower assembly. Insert one of the hex screws into all three pieces and tighten. 3. Insert the top screw through the thermal switch bracket and into the blower assembly. Tighten screw. 4. Connect the blue wire on the blower assembly to the right side of the thermal switch. 5. Connect the black wire to the left side of the thermal switch. Thermal Switch with Bracket IMPORTANT: For clarity, gas valve assembly and grate/burner assembly are not shown in Figures 30 through 33, page 17. They will, however, be in your fireplace when you are installing the blower. Also for clarity the firebox is shown with dotted lines. 1. Open lower louver panel or remove for easier access. 2. Place the blower against the lower rear wall of firebox outer wrapper with the exhaust port directed upward. Align the holes in the top mounting tabs of blower with holes in wall of wrapper (see Figure 30, page 17). Using the two screws provided, mount blower and tighten screws securely. Note: For DA3610TA, make sure the thermal switch is comfortably under the back of the firebox as shown in Figure 31, page 17. 3. Be sure to securely attach all wire terminals to terminals on blower motor (and thermal switch where applicable) and that the screw retaining the green ground wire is tight. 4. Remove screws securing the plate containing the ON/OFF switch to the bottom of the firebox and set aside. 5. Place speed control against back of this plate and push the plastic control shaft through opening (see Figure 32, page 17). 6. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until tight against the plate. Place control knob provided onto shaft (see Figure 32, page 17). 7. Replace plate containing switches and tighten screws securely. Black Wire Blower Assembly Place the fireplace into position and shim with noncombustible material if needed. Nail the side flanges to the framing to secure the unit in place. There are two floor brackets included with each unit. Use these as an alternative method of securing the fireplace. IMPORTANT: Make sure fireplace is level before securing. If fireplace is not level it will not work properly. White Wire Installing GA3700/DA3610TA Blowers Green Wire Hex Head Screws Blue Wire Figure 29 - Attaching Thermal Switch to DA3610TA Thermostatically-Controlled Blower Accessory 16 106516 OWNER’S MANUAL FIREPLACE INSTALLATION 9. Continued 8. Plug in blower power cord. a. If your fireplace system is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Install one plastic bushing provided into the 1 1/2" hole in the outer casing through which the power cord will exit. Install the second plastic bushing provided into the floor support bracket if exiting through the right side (see Figure 33). Route power cord through (both) plastic bushing(s) and plug the power cord into a properly grounded 3-prong wall receptacle near the firebox. b. If your fireplace system installation is recessed and/or pre-wired, a qualified installer must make all electrical connections for the outlet kit included with the fireplace. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by rotating knob fully counterclockwise before continuing. WARNING: Never touch the blower wheel while in operation. 10. Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 3" to the right of the blower speed control bracket (see Figure 33). WARNING: Failure to position the parts in accordance with supplied diagrams or failure to use only parts specifically approved with this heater may result in damage or personal injury. 11. Connect or reconnect gas supply to fireplace per Connecting Fireplace to Gas Supply on page 19 of this manual. WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes. Firebox Back Firebox Bottom Firebox Flange Blower Thermal Switch Thermal Switch Bracket Thermal Switch Side View Figure 31 - Locating Thermal Switch Against Back of Firebox Lower Rear Wall of Firebox Wrapper Speed Control Control Knob Blower Screws Control Shaft Locknut Figure 32 - Attaching Speed Control to Firebox Lower Louver Panel Exhaust Port Top Mounting Tab Plastic Bushing Wiring Diagram Blower Speed Control Bracket Figure 30 - Mounting Blower to Firebox 106516 Figure 33 - Installing Plastic Bushing and Wiring Diagram Sticker 17 Continued BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® FIREPLACE INSTALLATION Continued INSTALLING GAS PIPING TO FIREPLACE LOCATION WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes. CAUTION: For propane/LP units, never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply. CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of pressure will occur. Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 35). Propane/LP Supply Tank External Regulator Installation Items Needed Before installing fireplace, make sure you have the items listed below. • external regulator (supplied by installer) • piping (check local codes) • sealant (resistant to propane/LP gas) • equipment shutoff valve * • test gauge connection * • sediment trap • tee joint • pipe wrench • approved flexible gas line with gas connector (if allowed by local codes) (not provided) * An CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA/AGA design-certified equipment shutoff valve from your dealer. For propane/LP connections only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 34. Pointing the vent down protects it from freezing rain or sleet. Vent Pointing Down IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves. CAUTION: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas. We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 35. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap/drip leg is not installed or is installed wrong, fireplace may not run properly. Figure 34 - External Regulator with Vent Pointing Down (Propane/LP Only) CSA/AGA Design-Certified Equipment Shutoff Valve with 1/8" NPT Tap* Approved Flexible Gas Line Natural - From Gas Meter (5" W.C. to 10.5" W.C. Pressure ) Propane/LP - From External Regulator (11" W.C. to 14" W.C. Pressure) 3" Minimum Cap Pipe Nipple Tee Joint Sediment Trap/Drip Leg Figure 35 - Gas Connection * The CSA/AGA design-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your dealer. 18 106516 OWNER’S MANUAL FIREPLACE INSTALLATION CHECKING GAS CONNECTIONS Continued CONNECTING FIREPLACE TO GAS SUPPLY WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once. 3. 4. Installation Items Needed • 5/16" hex socket wrench or nut-driver • sealant (resistant to propane/LP gas, not provided) 1. Open lower louver door panel by gently pulling forward. 2. Route flexible gas line (provided by installer) from equipment shutoff valve to fireplace. Route flexible gas supply line through one of the access holes on side of fireplace. 3. Attach flexible gas line from gas supply to control valve (see Figure 36). 4. Check all gas connections for leaks. See Checking Gas Connections. WARNING: Never use an open flame to check for a leak. Apply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once. Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. 2. To Gas Supply (Natural) 5. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air. Check all joints of gas supply piping system. Apply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once. Reconnect fireplace and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage heater regulator. Cap off open end of gas pipe where equipment shutoff valve was connected. Equipment Shutoff Valve To External Regulator (Propane/LP) Control Valve Flexible Gas Line from Equipment Shutoff Valve Provided by Installer Figure 36 - Attaching Flexible Gas Line To Control Valve Continued 106516 19 BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® FIREPLACE INSTALLATION Continued Open ON POSITION Equipment Shutoff Valve Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. 2. 3. Close equipment shutoff valve (see Figure 37). Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air. Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 38 for propane/LP or Figure 39 for natural). Apply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once. Pressure Testing Fireplace Gas Connections 1. 2. 3. 4. 5. 6. Open equipment shutoff valve (see Figure 37). Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace. Make sure control knob of fireplace is in the OFF position. Check all joints from equipment shutoff valve to thermostat gas valve (see Figure 38 for propane/LP or Figure 39 for natural). Apply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once. Light fireplace (see Operating Fireplace, pages 25 through 27). Check all other internal joints for leaks. Turn off fireplace (see To Turn Off Gas to Appliance, page 25). OFF POSITION Closed Figure 37 - Equipment Shutoff Valve Propane/LP Supply Tank Equipment Shutoff Valve Gas Valve Figure 38 - Checking Gas Joints for Propane/LP Gas Fireplace Equipment Shutoff Valve Gas Meter Gas Valve Figure 39 - Checking Gas Joints for Natural Gas Fireplace 20 106516 OWNER’S MANUAL FIREPLACE INSTALLATION Continued INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1 5. WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures. 6. WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur. NOTICE: The GWMT1 includes 25' of wire for installation. Your fireplace includes 15' of wire for accessory installation. Choose the length that best fits your needs when installing this accessory. 1. 2. 3. 4. Open lower louver panel. The valve is attached to the underside of the firebox assembly. Disconnect the wire that runs from TH to TPTH from the valve as shown in Figure 40. Connect one terminal of the provided wire for the wall thermostat to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 41. If wires are not connected as shown the thermostat will not work. Route the wire through openings provided on the sides of the fireplace to a convenient location to mount your thermostat (no outside wall). IMPORTANT: The wire may be shortened but must not be lengthened. The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air conditioning ducts. Gently remove the cover of the thermostat from the base. Grasp the sides of the cover firmly and pull to separate from the base. Feed the electrical wires through the rectangular slots (from the back) on each side of the base (see Figure 42). Feed wires through rectangular slots Figure 42 - Back View of Thermostat Base WARNING: Do not connect this thermostat to a power source. Electrical shock and/or fire hazard will occur. Connect one bare wire end to each terminal (“W” and “R”) of the thermostat base (see Figure 43). 8. Install the base to the wall with screws provided with thermostat. 9. Move the temperature adjustment back and forth to insure the bimetal is free from restrictions. 10. Replace the cover onto the base. (Upon installation, the thermostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper operation.) 11. Set the temperature adjustment to the desired setting. This thermostat has been electronically calibrated at the factory. No adjustment or leveling is necessary. W 7. R INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2 NOTICE: The GWMS2 includes 25' of wire for installation. Your fireplace includes 15' of wire for accessory installation. Choose the length that best fits your needs when installing this accessory. 1. To Wall Optional Remote Accessory t Figure 41 - Control Valve Terminals 3. 4. Figure 40 - Disconnecting TH to TPTH Wire Terminal “R” Figure 43 - Thermostat Base Terminals “W” and “R” 2. 106516 Terminal “W” Connect one terminal of the provided wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 41. If wires are not connected as shown the switch will not work. Route the wire through openings provided on the sides of the fireplace to a convenient location to mount your switch. Connect one bare wire end to each of the terminals of the GWMS2 wall switch. Install the wall switch and cover in the wall. Continued 21 BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® FIREPLACE INSTALLATION Continued INSTALLING OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES - GHRC AND GHRCT NOTICE: Use only alkaline batteries (not included). Installing 9-Volt Alkaline Battery into Receiver 1. 2. 3. 4. 5. 6. 7. Open bottom louver and locate the switch bracket on the left. Unscrew the switch bracket. Lean bracket forward so you are able to access the back of the remote receiver. Locate the battery clip mounted on the back of the receiver. Slide a 9-volt alkaline battery (not included) through the clip. Attach the terminal wires to the battery. Remove the wire that runs from TH to TPTH from the valve (see Figure 40, page 21). Connect wires from receiver to TH and TPTH on the valve (see Figure 41, page 21). Replace the switch bracket. Installing 9-Volt Battery in HandHeld Remote Control Unit Remove battery cover on back of remote control unit. 2. Attach terminal wires to a 9-volt alkaline battery (not included). Place battery into the battery housing. 3. Replace battery cover onto remote control unit. Terminal Wires Figure 44 - Attaching Alkaline Battery to Receiver Remote Control Unit Battery Housing Figure 45 - Installing Alkaline Battery in Hand-Held Remote Control Unit REMOVING/REPLACING GLASS DOOR Figure 46 - Removing Top Louver Panel Screw You must remove glass door to install optional brick liners, logs, lava rock, and ember material. Glass Door Assembly CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part information see Replacement Parts, page 32. 1. 9-Volt Battery Battery Cover 9-Volt Battery Receiver Terminal Wires Battery Clip Top Louver Panel 1. 2. 3. 4. Remove the upper louver panel by lifting upward and out (see Figure 46). Remove the screws from the three tabs at the top of the glass door while holding door securely keeping it from falling forward. Grasp door by both sides and ease it upward off of the lower bracket (see Figure 47). To replace glass door, follow the above instructions in reverse. 22 Lower Bracket for Glass Door Assembly Figure 47 - Removing/Replacing Glass Door 106516 OWNER’S MANUAL FIREPLACE INSTALLATION Continued INSTALLING OPTIONAL BRICK LINER D8037A Left Side Brick Panel WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before installing brick liner. This brick liner kit is optional. You may purchase brick liner from your local dealer or see Accessories, pages 34 and 35. CAUTION: Always handle brick panels with two hands. Do not force brick panels into place. Excessive force will break brick panels. Remove glass door. See Removing/Replacing Glass Door, page 22. 2. If installing brick liner in new fireplace, go to step 3. If installing brick liner in an existing fireplace, carefully remove logs, lava rock, and ember material. 3. Install left side brick panel first by sliding it between the grate and the side of the firebox (see Figure 48). 4. Slide the left retainer bracket against the left side brick panel. Loosely secure the bracket screw. This secures the left side brick panel. 5. Install the right brick panel using the same method described in step 3. 6. Slide the right retainer bracket against the right side brick panel. Loosely secure the bracket screw. This secures the right side brick panel. 7. Install rear brick panel. Rest bottom edge of panel on back edge of grate (see Figure 49). 8. Loosely secure retainer brackets to grate. Brackets are adjustable left to right to allow proper placement of panel. These will hold rear panel in place. 9. Tighten all bracket screws. 10. Follow instructions on page 24 to install logs, lava rock, and ember material. 11. Replace glass door (see page 22). Figure 48 - Installing Left Side Brick Panel 1. 106516 Rear Brick Panel Retaining Brackets Figure 49 - Installing Rear Brick Panel and Retainer Brackets Continued 23 BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® FIREPLACE INSTALLATION 7. Continued INSTALLING LOGS, LAVA ROCK AND GLOWING EMBERS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with fireplace. 8. Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto the exposed section of the front burner and along the space between the burner and grate prongs (see Figure 55). This will create the glowing ember appearance as the flame touches the ember material. Do not block air slots by using too much ember material in one area. It is not necessary to use all of the ember material provided. Replace the glass door. See Removing/ Replacing Glass Door, page 22. 2. 3. 4. 5. 6. Place log #1 (back log) on top of grate. Make sure the notches in the bottom of the log fit over the grate (see Figure 50). Rest log #2 (large front log) on the pins on the front part of the grate (see Figure 51). Place log #3 (“C”-shaped crossover log) onto the rear and front logs. Make sure it is seated properly on the smooth surface on the front log and on the pin on the back log as shown in Figure 52. Place log #4 (small, round log) on the pin on the right side of front log as shown in Figure 53 Place log #5 (small log) onto the front left part of the grate making sure the notches fit over the prongs of the grate . See Figure 54. Place lava rock along sides and front of firebox bottom in areas that are visible only. It is not necessary to use all of the lava rock provided. Figure 52 - Installing Log No. 3 WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken. Remove glass door. See Removing/Replacing Glass Door, page 22. Install logs according to the following instructions. 1. 3 4 1 Figure 53 - Installing Log No. 4 5 Figure 50 - Installing Log No. 1 Figure 54 - Installing Log No. 5 2 NOTICE: Do not put lava rock on burner or under burner. Placing lava rock on burner could cause performance problems. Ember Material Figure 51 - Installing Log No. 2 24 Figure 55 - Placing Ember Material on Burner 106516 OWNER’S MANUAL FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. LIGHTING INSTRUCTIONS 1. 2. 3. 5. 106516 7. 8. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information in column one. If you don't smell gas, go to the next step. The pilot is located by the main burner and should not require accessing for lighting. Turn gas control knob counterclockto “PILOT”. wise 9. Push in gas control knob all the way and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8. • If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier. • If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 10. Reconnect the wire that runs from TH to TPTH from the valve. 11. Turn on all electric power to the fireplace. 12. Turn gas control knob counterclockto “ON”. wise 13. This valve is equipped with a HI/LO feature. Set fireplace input as desired. 14. Close lower louver panel. TO TURN OFF GAS TO APPLIANCE 1. Open lower louver panel. 2a. If Using Optional ON/OFF Switch: Turn ON/OFF switch to “OFF”. 2b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to prevent draining battery. Gas Control Knob Variable Control Knob Piezo Ignitor LOT PI IH ON 4. STOP! Read the safety information in column one. Open lower louver panel. Disconnect the wire that runs from TH to TPTH from the valve. Turn off all electric power to the fireplace. Push in gas control knob slightly and to “OFF”. turn clockwise 6. OFF OPERATING FIREPLACE LO Figure 56 - Control Valve 25 3. 4. 5. Turn off all electrical power to the appliance if service is to be performed. Push in gas control knob slightly and to “OFF”. turn clockwise Close lower louver panel. Shutting Off Burners Only (pilot stays lit) You may shut off the burners and keep the pilot lit by doing one of the following: 1. Turn gas control knob clockwise to the PILOT position. 2. Set selector switch in the OFF position. MANUAL LIGHTING PROCEDURE 1. 2. 3. 4. 5. Remove glass door (see Removing/Replacing Glass Door, page 22). Follow steps 1 through 8 under Lighting Instructions. Depress gas control knob and light pilot with match. Keep gas control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release gas control knob. Now follow steps 10 through 14, column 2. Replace glass door (see Removing/Replacing Glass Door, page 22). OPTIONAL REMOTE OPERATION Note: All remote control accessories must be purchased separately (See Accessories on pages 34 and 35). Follow instructions included with the remote control. Thermostat Control Operation (Optional GHRCT Only) The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The burners will turn on and off automatically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc. NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instructions. Continued BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® Continued GHRCTA Series Operation: 2b. Press the AUTO/ON/OFF button on the hand-held remote control (see Figure 58). The lights to the left of the button will show AUTO, ON, or OFF. • In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit. • In the AUTO mode, the thermostat in the hand-held remote unit controls the room temperature. To increase the room temperature, press the top arrow of the TEMP button. To lower the room temperature, press the bottom arrow of the TEMP button. At higher settings the heater will run longer. ON T ON OFF REMOTE ON OFF Variable Control Knob LO 2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit. Blower Control Knob (Optional Accessory) OF GHRC Series Operation: 3. PILO After lighting, let pilot flame burn for about one minute. Turn gas control knob on the control valve to ON position. Turn variable control knob anywhere between WARMER and COOLER. Slide the selector switch to the REMOTE position. Note: The burners may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burners on and off with either optional hand-held remote control unit. IMPORTANT: Do not leave the selector switch in the REMOTE position when the pilot is not lit. This will drain the battery. IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation. F 1. IMPORTANT: This remote control has been specially engineered to take an air temperature sample every 5.5 minutes in the auto mode. It will not respond immediately to the temperature setting being turned up or down. IMPORTANT: The hand-held remote control unit must be near the heater. Do not keep the hand-held remote control unit too close to the heater. The thermostat on the hand-held remote control unit will heat up too quickly and turn the heater off. To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position. HI OPERATING FIREPLACE Gas Control Knob in On Position Selector Switch in Remote Position OPERATING OPTIONAL BLOWER ACCESSORY Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel. Both the GA3700 manual blower and the DA3610TA thermostatically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate. Note for DA3610TA Only: If you are using DA3610TA blower with optional thermostat (wall mount or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases. The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air. Figure 57 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation Increases Room Temperature in AUTO Mode Shows Temperature Setting Decreases Room Temperature in AUTO Mode The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected Turns Burners On or Off and Allows You to Choose the Auto Setting Figure 58 - Hand-Held Thermostat Remote Control Unit Selections (GHRCTA Only) 26 106516 OWNER’S MANUAL OPERATING FIREPLACE Continued OPERATING OPTIONAL GWMT1 WALL MOUNTED THERMOSTAT WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire hazard will occur. Light the fireplace as instructed in Lighting Instructions on page 25. Set wall thermostat to desired temperature. This thermostat has been electronically calibrated at the factory and requires no adjustment or leveling. Upon installation, the thermostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper operation. To turn the fireplace off, adjust thermostat to the lowest setting and turn the gas control knob back to PILOT. The pilot will remain lit. Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary. The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure 59. The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile. Make sure the heater switch is on AUTO. This wall switch works just like the conventional light switch. Flip the switch up for on and down for off. If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after installation to ensure proper installation and performance. Figure 60 shows a typical flame pattern for BHDV34NB and BHDV34PB. If burner flame pattern differs from that described: • turn fireplace off (see To Turn Off Gas to Appliance, page 25) • see Troubleshooting, pages 29 through 31 Thermopile 3/8" to 1/2" Pilot Burner 1/8" Thermocouple Piezo Ignitor Figure 59 - Pilot Assembly Note: Make sure that this switch is not in a position to be mistaken for a light switch. This may result in the heater being inadvertently turned on without the proper precautions being taken. See installation instructions on page 21 of this manual. 106516 Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions. If your pilot assembly does not meet these requirements: • turn fireplace off (see To Turn Off Gas to Appliance, page 25) • see Troubleshooting, pages 29 through 31 IMPORTANT: To turn the pilot off, turn the gas control knob on the heater to the OFF position. OPERATING OPTIONAL GWMS2 WALL MOUNTED SWITCH BURNER FLAME PATTERN INSPECTING BURNERS 27 Figure 60 - Typical Flame Pattern for models BHDV34NB and BHDV34PB BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® CLEANING AND MAINTENANCE WARNING: Turn off fireplace and let cool before cleaning. CAUTION: You must keep control areas, burners, and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc. GLASS DOOR WARNING: Handle glass door panel with care. Do not strike, slam, or otherwise abuse glass. Do not operate fireplace with the glass door removed, cracked, or broken. WARNING: Do not use abrasive cleaners as this may damage glass. Use a nonabrasive household glass cleaner to clean glass. Do not clean glass when hot. Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, nonabrasive household cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door on page 22 of this manual when removing glass door for cleaning. WARNING: Only parts supplied by the manufacturer should be used when replacing broken or damaged glass door panel (see Replacement Parts, page 32). This glass door panel is a complete unit. No substitute materials may be used. CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass. If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 22). Vacuum all glass pieces with a shop vac. CAUTION: Do not vacuum if pieces are hot. Use only the ceramic glass door replacement intended for this fireplace (see Replacement Parts, page 32 for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 22 for instructions for replacing glass door. WARNING: Do not operate fireplace with the glass door removed, cracked, or broken. • If you remove logs for cleaning, refer to Installing Logs, Lava Rock, and Glowing Embers, page 24, to properly replace logs. • Use a vacuum cleaner to remove any carbon buildup on logs. • Replace log(s) if broken. See Replacement Parts on page 32. • Replace ember material periodically as needed. See Replacement Parts on page 32. VENTING SYSTEM Conduct annual inspection of the venting system following these guidelines: 1. Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced immediately by a qualified service person. 2. Remove the vent cap and shine a flashlight into the vent. Remove any foreign material. 3. Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes, and fittings and can be caused by having excessive lateral runs, too many elbows, or exterior portions of the system being exposed to cold weather. 4. Inspect joints to verify that no pipe section or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity. PILOT AND BURNERS • Remove ember material before cleaning burners and replace when cleaning is complete. • Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint. • Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint. 28 106516 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. Note: For additional help, visit DESA International’s technical service web site at www.desatech.com. CAUTION: Never use a wire, needle, or similar object to clean pilot. This can damage pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed, there is no spark at pilot 1. Ignitor electrode not connected to ignitor cable 2. Ignitor cable pinched or wet 1. Reconnect ignitor cable 3. Piezo ignitor nut is loose 4. 5. 6. 7. When ignitor button is pressed, there is spark at pilot but no ignition Broken ignitor cable Bad piezo ignitor Ignitor electrode broken Ignitor electrode positioned wrong 1. Gas supply turned off or equipment shutoff valve closed 2. Gas control knob not in PILOT position 3. Gas control knob not pressed in while in PILOT position 4. Air in gas lines when installed 5. Depleted gas supply (propane/LP models only) 6. Pilot is clogged 7. Gas regulator setting is not correct Pilot lights but flame goes out when control knob is released 1. Gas control knob not fully pressed in 2. Gas control knob not pressed in long enough 3. Equipment shutoff valve not fully open 4. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged pilot 5. Thermocouple connection loose at control valve 6. Thermocouple damaged 7. Control valve damaged www.desatech.com 106516 29 2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 3. Tighten nut holding piezo ignitor. Nut is located behind the mounting bracket 4. Replace ignitor cable 5. Replace piezo ignitor 6. Replace pilot assembly 7. Replace pilot assembly 1. Turn on gas supply or open equipment shutoff valve 2. Turn gas control knob to PILOT position 3. Press in gas control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Contact local propane/LP gas company 6. Clean pilot (see Cleaning and Maintenance, page 28) or replace pilot assembly 7. Replace gas control 1. Press in gas control knob fully 2. After pilot lights, keep gas control knob pressed in 30 seconds 3. Fully open equipment shutoff valve 4. A) Contact local gas company B) Clean pilot (see Cleaning and Maintenance, page 28) or replace pilot assembly 5. Hand tighten until snug, then tighten 1/4 turn more 6. Replace thermocouple 7. Replace control valve Continued BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner does not light after pilot is lit 1. Burner orifice clogged 1. Clean burner (see Cleaning and Maintenance, page 28) or replace burner orifice 2. Contact local propane/LP or natural gas company 3. Reconnect leads (see Wiring Diagram, page 32) 4. Replace thermopile 2. Inlet gas pressure is too low 3. Thermopile leads disconnected or improperly connected 4. Thermopile is defective Delayed ignition burner 1. Manifold pressure is too low 2. Burner porting or orifice clogged 1. Contact local propane/LP or natural gas company 2. Clean burner (see Cleaning and Maintenance, page 28) or replace burner orifice 2. Damaged burner 3. Gas regulator defective 1. Clean burner (see Cleaning and Maintenance, page 28) or replace burner orifice 2. Replace damaged burner 3. Replace gas control Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing 1. Problem will stop after a few hours of operation Heater produces a whistling noise when burner is lit 1. Turning gas control knob to HI position when burner is cold 2. Air in gas line 1. Turn gas control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by local propane/LP or natural gas company 3. Clean burner (see Cleaning and Maintenance, page 28) or replace burner orifice Burner backfiring during combustion 1. Burner orifice is clogged or damaged 3. Dirty or partially clogged burner orifice Glass soots 1. Flame impingement on logs 2. Debris around burner air mixer 1. Adjust the log set so that the flame does not excessively impinge on it 2. Inspect the opening at the base of the burner to see that it is NOT packed with any type of material Fireplace produces a clicking/ticking noise just after burners are lit or shut off 1. Metal expanding while heating or contracting while cooling 1. This is common. If noise is excessive, contact qualified service person Remote does not function 1. Battery is not installed or battery power is low 1. Replace 9-volt batteries in receiver and remote control www.desatech.com 30 106516 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. • • • • IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Fireplace produces unwanted odors 1. Gas leak. See Warning statement above 1. Locate and correct all leaks (see Checking Gas Connections, pages 19 and 20) Fireplace shuts off in use 1. High or gusting winds 1. Fireplace has been tested for up to 40mph winds. However, extreme conditions may occur. See Lighting Instructions on page 25 2. Contact local propane/LP or natural gas company 3. Clean pilot (see Cleaning and Maintenance, page 28) 4. Locate and correct all leaks (see Checking Gas Connections, pages 19 and 20) 5. Horizontal vent termination should slope down only enough to prevent any water from entering the unit. The maximum downward slope of the vent termination is 1/4" for any horizontal run 6. Tighten glass 2. Low line pressure 3. Pilot is partially clogged 4. Inner vent pipe leaking exhaust gasses into system 5. Horizontal vent improperly pitched 6. Glass too loose and air tight gasket leaks in corners after usage 7. Bad thermopile or thermocouple 8. Improper vent cap installation 7. Replace faulty component 8. Check for proper installation and freedom from debris or blockage Gas odor even when control knob is in OFF position 1. Gas leak. See Warning statement above 2. Control valve defective 1. Locate and correct all leaks (see Checking Gas Connections, pages 19 and 20) 2. Replace control valve Gas odor during combustion 1. Gas leak. See Warning statement above 1. Locate and correct all leaks (see Checking Gas Connections, pages 19 and 20) Dark residue on logs or inside of fireplace 1. Improper log placement 1. Properly locate logs (see Installing Logs, Lava Rock, and Glowing Embers, page 24) 2. Clean out air holes at burner inlets. Periodically repeat as needed 3. Remove blockage or replace burner 2. Air holes at burner inlet blocked 3. Burner flame holes blocked www.desatech.com 106516 31 BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® REPLACEMENT PARTS WIRING DIAGRAM CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can not supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564). When calling DESA International, have ready • your name • your address • model and serial numbers of your fireplace • how fireplace was malfunctioning • type of gas used (propane/LP or natural gas) • purchase date Usually, we will ask you to return the defective part to the factory. PARTS NOT UNDER WARRANTY Contact authorized dealers of this product. If they can not supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information. When calling DESA International, have ready • model number of your fireplace • the replacement part number TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564). You can also visit DESA International’s technical service web site at www.desatech.com. Variable Fan Switch Off Fan Switch (N.O.) 1 2 Black On Blue 110/115 V.A.C. Black Blower Motor White Green Figure 61 - Blower Wiring Diagram for Thermostat-Controlled Models SERVICE HINTS When Gas Pressure Is Too Low • • • • pilot will not stay lit burners will have delayed ignition fireplace will not produce specified heat propane/LP gas supply might be low (propane/LP units only) When Gas Quality Is Bad • pilot will not stay lit • burners will produce flames and soot • fireplace will backfire when lit If you feel your gas pressure is too low or gas quality is bad, contact your local natural or propane/LP gas supplier. 32 106516 OWNER’S MANUAL SPECIFICATIONS BHDV34NB BHDV34PB 17,000/24,000 Btu/hr 17,000/22,000 Btu/hr Natural Propane/LP Piezo Piezo Manifold Pressure 3.5" w.c. 10.0" w.c. Minimum Inlet Supply Pressure 4.5" w.c. 11.0" w.c. 70% 70% Gas Type Ignition Thermal Efficiency Dimension, Inches/mm (HxWxD) Fireplace (Actual size of firebox. Measurements do not 32 3/16" x 34 3/8" x 18 1/2" include nailing flanges or 817 x 873 x 470mm stand-offs). Carton Weight, lbs/kg Fireplace Shipping 106516 32 3/16" x 34 3/8" x 18 1/2" 817 x 873 x 470mm 37" x 40" x 21" 940 x 1016 x 533mm 37" x 40" x 21" 940 x 1016 x 533mm 123 lbs/56 kg 126 lbs/57 kg 123 lbs/56 kg 126 lbs/57 kg 33 BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® ACCESSORIES Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382 for information. You can also write to the address listed on the back page of this manual. ¢¢¢¢¢¢ ,,,,,, QQQQQQ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,,,,,, QQQQQQQQQQ ¢¢¢¢¢¢¢¢¢¢ ,,, QQQ ¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,,,,,, QQQQQQQQQQ ¢¢¢¢¢¢¢¢¢¢ ,,, QQQ ¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,,,,,, QQQQQQQQQQ ¢¢¢¢¢¢¢¢¢¢ ,,, QQQ ¢¢¢ CABINET MANTEL GM100FC Series - Walnut Finished GM101UC Series - Unfinished GM106FC Series - Oak Finished with Medium Stain GM107UC Series - Unfinished GM102WC Series - Off White Paint Shown with optional base and laminate hearth and mantel trim accessories. Dimensions (WxHxD): 56 3/4" x 48 3/4" x 22 3/4" IMPORTANT: The above mantel model numbers must end with the letter "C" to fit this fireplace. HEARTH BASE TRIM KIT (Not Shown) - For Use With Hardwood Hearth Base ¢¢¢¢¢¢ ,,,,,, QQQQQQ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ ,,,,,, QQQQQQ ¢¢¢¢¢¢ CORNER MANTEL G3003J Series - Jade Marble Laminate G3003S Series - Sandstone Marble Laminate G3003B Series - Black Onyx Marble Laminate GM200F Series - Walnut Stained Hardwood Veneer GM201U Series - Unfinished GM202F Series - Stained Oak Veneer Shown with optional laminate mantel trim accessory. Dimensions (WxHxD): 60 7/8" x 48 3/4" x 34 5/8" SLIM HEARTH BASE (Not Shown) G3005J Series - Jade Marble Laminate G3005S Series - Sandstone Marble Laminate G3005B Series - Black Onyx Marble Laminate The slim hearth base allows you to further customize your fireplace. Can be used with cabinet or corner mantels. Dimensions (WxHxD): 41 7/8" x 5/8" x 10" HARDWOOD HEARTH BASE G3000F Series- Walnut Finished G3001U Series - Unfinished G3006F Series - Oak Finished with Medium Stain G3007U Series - Unfinished Oak G3004W Series- Off White Paint The hearth base creates a handsome riser for the fireplace (cannot be used with corner mantel). 1 9 Dimensions (WxHxD): 58" x 6 /2" x 28 /16" HARDWOOD CORNER HEARTH BASE (Not Shown) - For Use With Corner Mantels G3008F Series - Walnut Stained Hardwood Veneer G3009U Series - Unfinished G3010F Series - Stained Oak Veneer The hearth base creates a handsome riser for the fireplace. Dimensions (WxHxD): 52 1/2" x 6" x 23 3/4" MANTEL TRIM (Not Shown) G3002J Series - Jade Marble Laminate G3002S Series - Sandstone Marble Laminate G3002B Series - Black Onyx Marble Laminate 34 106516 OWNER’S MANUAL ACCESSORIES Continued DUPLEX OUTLET KIT GA3555 (Not Shown) ON/OFF WALL MOUNT SWITCH - GWMS2 (Not Shown) For all models. Allows the heater to be manually turned on and off. For recessed installation when accessory blowers are used. BRASS PERIMETER TRIM KIT - GA6090 (Not Shown) RECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC SERIES Optional three sided brass trim kit covers unfinished edges around fireplace. Provides a finished appearance with the class of brass. BRASS LOUVER KIT D6034 (Not Shown) MANUAL BLOWER KIT GA3700 These louvers will give your fireplace an elegant look and allows you to customize your fireplace. They easily replace the standard black louvers by screwing into place. Manual-variable control blower accessory. For all models. Allows the heater to be turned on and off conveniently. WA R ME R DECORATIVE 2-PIECE BRASS ACCENT TRIM D5037 (Not Shown) These strips have a magnetic backing which makes installation and removal quick and easy. They are designed to go at the top and bottom of the glass door on BHDV units. Note: Remove the plastic film covering on strips before installing on fireplace. BRICK LINER D8037A (Not Shown) This brick liner adds a touch of style to your direct-vent fireplace and comes with easy to follow instructions for installation. TE OLE ON OFF R MP RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - GHRCTA SERIES THERMOSTATICALLYCONTROLLED BLOWER KIT DA3610TA Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instructions included in this manual. WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 (Not Shown) Allows easy wall access to the operation of your fireplace. This will allow you thermostatic control with the convenience of a wall switch. 106516 CO AU TO 35 Allows the fireplace to be operated in a manually or thermostatically-controlled mode. You can adjust your heat settings and turn the heater on or off without leaving the comfort of your easy chair. BHDV34NB AND BHDV34PB DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP) ® ILLUSTRATED PARTS BREAKDOWN BHDV34NB BHDV34PB 33 2 7 11 (Included in Hardware Pack) 46 38 31-3 31-5 6 25 48 31-1 45 31-2 44 26 27 31-4 29 1 39 6 20 18 32 34 6 4 19 16 24 37 30 28 21 22 36 6 14 17 28 35 15 9 5 8 23 40 41 13 12 5 47 5 32 10 42 32 3 7 43 36 106516 OWNER’S MANUAL PARTS LIST This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 32 of this manual. DIRECT-VENT FIREPLACE BHDV34NB BHDV34PB KEY NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 106516 PART NUMBER DESCRIPTION 104445-01 105278-01 105297-01 104479-10BR M11084-26 M11084-46 105394-01 104443-01 104486-01 104482-01 104483-01 104491-01 104518-01 104527-01 104528-01 104537-01 104496-01 104496-02 104497-01 104497-02 104498-01 104499-01 104500-01 104501-01 104502-01 104503-01 104504-01 104504-02 104506-01 104506-02 104507-01 Top Outer Casing Outer Casing Bottom Outer Casing Firebox Assembly Screw, Hex Screw, Hex Louver, Extruded Firebox Support, Right Firebox Support, Left Switch Bracket Floor Mounting Bracket Relief Cover Relief Cover Gasket Relief Spring Relief Washer Valve Bracket SIT Valve, Natural SIT Valve, Propane/LP SIT Pilot, Natural SIT Pilot, Propane/LP Thermocouple Thermopile Ignitor Ignitor Bracket Ignitor Screw Ignitor Wire Burner, Natural Burner, Propane/LP Orifice, Natural Orifice, Propane/LP Brass Elbow QTY. 1 1 1 1 50 13 2 1 1 1 2 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 KEY NO. PART NUMBER DESCRIPTION 28 29 30 31 31-1 31-2 31-3 31-4 31-5 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 104508-01 104509-01 104510-01 107165-01 107344-02 107345-02 107346-01 107347-02 107348-01 M10908-2 M12461-65 H5C4-20B NTC-4C M12461-26 104555-02CJ 105775-14 104615-02 104490-02CJ 105450-01CK 104313-01 104313-02 104954-01 104963-01 104955-01 105575-01 105325-01 Brass Fitting Aluminum Tubing Assy Pilot Tubing Assy Log Set Rear Log Front Log Crossover Log Log Piece Top Log Screw Screw Bolt Locknut Screw Grate Assembly Glass Door Assy Insulation Baffle Front Assembly Hinge, Pin Hinge, Pin Screw Washer Nut Wire Harness Burner Baffle QTY. 2 1 1 1 1 1 1 1 6 3 2 2 4 1 1 1 1 1 1 1 3 3 3 1 1 PARTS AVAILABLE - NOT SHOWN GA6060 104529-01 37 Lava Rock Ember Material 1 1 WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY DIRECT-VENT FIREPLACE DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented. This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit. This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner. TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. For information about this warranty write: INTERNATIONAL 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com 106516 01 NOT A UPC 106516-01 Rev. A 03/00
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.1 Linearized : No Page Count : 38 Create Date : 2000:03:31 14:32:47 Producer : Acrobat Distiller 3.0 for Power Macintosh Subject : 106516-01 Creator : Adobe PageMaker 6.52 Title : 106516-01 Author : mac3EXIF Metadata provided by EXIF.tools