Vantage Controls RFE1000 Home automation transmitter User Manual Enabler Instructions

Vantage Controls Inc. Home automation transmitter Enabler Instructions

User Manual

Download: Vantage Controls RFE1000 Home automation transmitter User Manual Enabler Instructions
Mirror Download [FCC.gov]Vantage Controls RFE1000 Home automation transmitter User Manual Enabler Instructions
Document ID163951
Application IDNMRRneB29I7qFXuZiKh9/Q==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize11.49kB (143608 bits)
Date Submitted2001-08-10 00:00:00
Date Available2001-08-01 00:00:00
Creation Date2001-07-03 08:16:15
Producing SoftwareAcrobat PDFWriter 4.0 for Windows NT
Document Lastmod2001-07-03 08:20:21
Document TitleEnabler Instructions.PDF
Document CreatorEnabler Instructions.doc - Microsoft Word
Document Author: jaredl

I n s t a l l a t i o n
1 0 6 1 SOUTH 8 0 0 EA S T • OR E M , U TAH 8 4 0 9 7 • TELEPHONE 8 0 1 . 2 2 9 . 2 8 0 0 • FACSIMILE 8 0 1 . 2 2 4 . 0 3 5 5 • W E B S I T E
www.vantageinc.com
RadioPoint- Enabler
Introduction
Connections
The RadioPoint Enabler adds RF communications ability to the
Vantage Master Controller. It allows Vantage RF products to
be installed within 100 feet of the Master Controller without
running station bus or other wiring between them. The
Enabler easily connects to the existing RS-232 and Power
connections on the master terminal board.
Connections to the Enabler are all made to the 5-position
removable screw terminal. The chart and figure below show how
the connections from the Master Power Enclosure to the Enabler
are made.
RF Enabler
+12V
GND
TX
RX
/RST
Mounting
For best performance, the Enabler should be mounted at least
6 inches away from the Master Power Enclosure and any other
metal enclosures or devices. Normally the Enabler should be
mounted to the wall or a stud above the Master Power
Enclosure. It may be mounted using Velcro or by hanging it on
two screws using the keyhole slots on the back.
Connection
Master Power Enclosure +12V
Master Power Enclosure GND
Master Power Enclosure TX
Master Power Enclosure RX
Master Power Enclosure RTS
IMPORTANT: In order to comply with the FCC RF exposure
requirements, this product must be installed and operated in
such a way that a minimum separation distance of 20 cm
(approximately 8 inches) is maintained from the antenna to any
persons. Operations that do not meet these requirements
must be avoided.
Indicators
LED
TX
RX
Function
Indicates the RF Enabler is transmitting
data.
Indicates the RF Enabler is receiving data.
Setup
When the connections have been made as described above,
insert the Master Controller (MC) into the Master Power
Enclosure (MPE).
Using the RadioPoint Enabler
The Enabler is used to enable the Master Controller to
communicate by wireless link with Vantage RF products. Once
the Enabler is installed, Q-Link can be used to configure
Vantage RF Products as they are installed on the network.
Trouble shooting
Wiring
6 conductor, 22 gauge wire or larger should be used between
the Enabler and the Master Power Enclosure. No more than
20 feet of wire may be used between Enabler and the Master
Power Enclosure. Run the wires through one of the knock-out
holes in the bottom of the Master Power Enclosure to keep the
low-voltage wiring away from the high-voltage portion of the
Master Power Enclosure. Verify that station
bus wiring conforms to Vantage guidelines.
−−
−−
Double check wiring using the chart to the left.
Is the Master Controller in place in the Master Power
Enclosure?
−− Make sure the Master Controller is not addressed to 0.
FCC ID: PII-RFE1000
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Radio Specifications
FCC ID# ............................................................. PII-RFE1000
Frequency Range .............................. 902-928 MHz ISM Band
Power Supply .............................................................. 12 VDC
Current required while transmitting................................180mA
Current required while receiving..................................... 70mA
Antenna Connection ................................. Permanent (Solder)
Antenna Gain ...................................................................2dBi
NOTE: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from
Transmit Power ...........................................................140mW
RF Technology ............ Frequency Hopping Spread Spectrum
Number of Hop Channels .....................................................25
RF Data Rate ........................................................ 19,200 bps
Interface Data Rate ............................................... 19,200 bps
Operating Temperature Range.................................. -40-70°C
that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for
help.
Changes or modifications to this product not expressly approved by
Vantage Controls could void the user’s authority to operate this
product.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Creator                         : Enabler Instructions.doc - Microsoft Word
Create Date                     : 2001:07:03 08:16:15
Title                           : Enabler Instructions.PDF
Author                          : jaredl
Producer                        : Acrobat PDFWriter 4.0 for Windows NT
Modify Date                     : 2001:07:03 08:20:21-06:00
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PII-RFE1000

Navigation menu