Venture Global PB-SDX Wireless transmitter User Manual 2
Venture Global Limited Wireless transmitter 2
Users Manual
USER MANUAL 1000-638 Installation Parts & Function Test Button/ LED Indicator Cable duct Take away the wire hole cover Insert the cable duct to the base Wiring Hole Connection wire Wiring hole cover Battery compartment Wire Socket Place the wires in the cable duct and replace the cable duct cover Plug the connection wire to the wire socket Cover Double-sided adhesive tape Power This unit using a long life battery CR123A. / 7mm 25mm Battery installation 1. Open the front cover using a small flat screw driver 2. Take out the connection wire in the battery compartment. 3. Install a CR123A battery to the battery compartment Mark the mounting holes on the celling using a pencil close to the alarm device. Requires an electric drill for holes to fix the transmitter with the provided ram plug and screws. Mount the transmitter beside the alarm device with the screws provided. Connect the two connection wires to the output of alarm device according to the user manual of the alarm device. Red connected to '+' Black connected to '-' CODE PAIRING & MELODY SELECTION Code Conflict Step 5: Once the zone and melody are selected, press the test button on the transmitter once to pair. If successful, the receiver (chime) will generate a short tone. Press the button to exit pairing mode, the system is ready to use. To stop the Chime whilst it is alerting press the reset button Test the transmitter To test the transmitter, press the test button once. the LED indicator will lit and will send a trigger signal to the receiver. Recommended test the transmitter once a month Test the connection To test the connection between the transmitter and smoke alarm, press the test button on the smoke alarm. the LED indicator on the transmitter will lit and will send a trigger signal to the receiver. Battery low indication LIGHT & CHIME LIGHT CHIME Step 1: Insert battery to the transmitter to be used. ID Step 2: Insert batteries to the receiver to be used (chime unit). Step 3: Enter pairing mode for receiver (chime unit). Press and hold the zone Select button for 3 seconds. The LED #1 will flash. Zone select button Step 4: Press the button again to Melody selector button move to the zone you wish to pair with. Press melody selector to scroll through the melodies. Once you hear your preferred melody, do not press again as it is now selected. If the transmitter coding is the same as another transmitter you must change the code. When you have changed the code re-pair the transmitter is needed. Open the cover Remove the battery Remark: Press and hold the test button, insert the battery whilst holding the button for 5 seconds. The LED will flash 5 times when a new code is generated This relay transmitter can work any devices with 3 to 9V output relay terminal. Assume to connect with alarm device has built-in output terminal with 3 to 9 volt output when the alarm device is activated. Red Black Transmitter Alarm device Connection wire needs correct with right polarity, connection will cause the transmitter does not work. wrong FCC Statement: Once the transmitter unit detect battery voltage is low, the LED indicator will blink every 10 second. If the transmitter is activated, The battery low information will be sent to the receiver for display. R&TTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: * Reorient or relocate the receiving antenna. * Increase the separation between the equipment and receiver. * Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: Modifications to this product will void the user's authority to operate this equipment.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Page Count : 1 Create Date : 2016:06:03 15:28:09+08:00 Modify Date : 2016:06:03 15:28:09+08:00 Producer : Corel PDF Engine Version 16.1.0.843 Author : wwliu Creator : CorelDRAW X6 Title : 無標題-2EXIF Metadata provided by EXIF.tools