Vermont Castings Dv580 Dv360 Operation Manual ManualsLib Makes It Easy To Find Manuals Online!
2014-12-11
: Vermont-Castings Vermont-Castings-Dv580-Dv360-Operation-Manual-121755 vermont-castings-dv580-dv360-operation-manual-121755 vermont-castings pdf
Open the PDF directly: View PDF .
Page Count: 56
Download | |
Open PDF In Browser | View PDF |
Direct Vent Gas Fireplace Models: DV360, DV580 INSTALLER / CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR OUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas supplier. Homeowner’s Installation and Operating Manual 6357 DV360/580 2/04 WHAT TO DO IF YOU SMELL GAS: • • • • Do not try to light any appliance. Do not touch any electric switch; do not sue any phone in your building. Immediately call your gas supplier from your neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. DE S I GN CE C E RT I F I E D RTIFI E D INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. 20010667 12/06 Rev. 5 DV360/580 Series Direct Vent Gas Fireplace Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions 2 .....................................................................................................................................3 Locating Your Fireplace ...............................................................................................3 Fireplace Dimensions ..................................................................................................4 Clearance to Combustibles ..........................................................................................6 Mantels ........................................................................................................................6 Hearth ..........................................................................................................................6 Framing & Finishing .....................................................................................................7 Final Finishing ..............................................................................................................7 Gas Specifications .......................................................................................................7 Gas Inlet and Manifold Pressures ................................................................................7 High Elevations ............................................................................................................8 Gas Line Installation ....................................................................................................8 Remote ON/OFF Switch Installation ............................................................................8 Alternate Switch Location ............................................................................................8 EB-1 Electrical Box ......................................................................................................9 Electronic Gas Control Valve .......................................................................................9 Optional Top Vent Application ....................................................................................10 General Venting General Venting ......................................................................................................... 11 General Venting Information - Termination Location ..................................................12 General Information Assembling Vent Pipes .............................................................13 How to Use the Vent Graph .......................................................................................14 Rear Wall Vent Application & Installation ...................................................................14 Vertical Sidewall Application & Installation .................................................................16 Below Grade Installation ............................................................................................20 Vertical Through-the-Roof Application & Installation ..................................................20 Venting Components .................................................................................................23 Operating Instructions Glass Information .......................................................................................................24 Louvre Removal .........................................................................................................24 Window Frame Assembly Removal ...........................................................................24 Glass Cleaning...........................................................................................................24 Installation of Optional Ceramic Panels .....................................................................24 Replacement of Ceramic Hearth Panels ...................................................................24 Installation of Logs .....................................................................................................25 Burner Lava Rock Placement ....................................................................................28 Large Lava Rock ........................................................................................................28 Flame & Temperature Adjustment..............................................................................28 Flame Characteristics ................................................................................................28 Inspecting the Venting System ..................................................................................28 Lighting and Operating Instructions (Honeywell Gas Valve) ......................................30 Lighting and Operating Instructions (SIT Valve) ........................................................31 Instructions for RF Comfort Valve ..............................................................................32 Troubleshooting Gas Control (Honeywell Gas Valve) ................................................36 Troubleshooting Gas Control (SIT 820 Millivolt Gas Valve) .......................................37 Troubleshooting Gas Control (SIT 822 Valve) ...........................................................38 Troubleshooting Gas Cotnrol (SIT 822 w/Synetek Electronic Control) ......................39 Fuel Conversion Instructions .....................................................................................40 Maintenance Cleaning the Standing Pilot Control System ..............................................................44 Replacement Parts ...................................................................................................................................45 Optional Accessories Fan Kits ......................................................................................................................49 Hard (Direct) Wire Hook Up .......................................................................................49 Remote Controls ........................................................................................................50 Ceramic Refractory Panels ........................................................................................50 Decorative Bay Windows ...........................................................................................50 Decorative Frame Trim ..............................................................................................50 Arch/Square Face Kit .................................................................................................51 For Use in Mobile Homes: Model DV360RMH ...................................................................................................52 Warranty ...................................................................................................................................55 Energuide ...................................................................................................................................56 20010667 DV360/580 Series Direct Vent Gas Fireplace Installation & Operating Instructions This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSAB149.1 Installation codes for Gas Burning Appliances and Equipment. If the unit is being installed in a mobile home, the installation should comply with the current CAN/CSA Z 240.4 code. For U.S.A Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1/NFPA 54. In the Commonwealth of Massachusetts, all gas fittings and installation of this appliance shall be done by a licensed gas fitter or licensed plumber. FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING: 1 . This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies. 2. Children and adults should be alerted to the hazards of the high surface temperatures of this fireplace and should stay away to avoid burns or ignition of clothing. 3. Children should be carefully supervised when in the same room as your fireplace. 4. Under no circumstances should this fireplace be modified. Parts removed for servicing should be replaced prior to operating this fireplace again. 5. Installation and any repairs to this fireplace must be performed by a qualified installer, service agency or gas supplier. A professional service person should be contacted to inspect this fireplace annually. Make it a practice to have all of your gas fireplaces checked annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc. 6. Control compartments, burners and air passages in this fireplace should be kept clean and free of dust and lint. Make sure the gas valve and pilot light are turned off before you attempt to clean this fireplace. 7. The venting system (chimney) of this fireplace should be checked at least once a year and if needed your venting system should be cleaned. 8. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. This fireplace should not be used as a drying rack for clothing, nor should Christmas stocking or decorations be hung in the area of it. 9. Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this fireplace. 10. The flow of combustion and ventilation air must not be obstructed in any way. 11. When fireplace is installed directly on carpeting, vinyl tile or any combustible material other than wood, this fireplace must be installed on a metal or wood panel extending the full width and depth of the fireplace. 12. This fireplace requires adequate ventilation and combustion air to operate properly. 13. This fireplace must not be connected to a chimney flue serving a separate solid fuel burning fireplace. 14. When the fireplace is not in use it is recommended that the gas valve be left in the OFF position. Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6 20010667 WARNING: Check with your electronics manufacturer before installing a television or other electronic device above this fireplace. This appliance may be installed in an aftermarket permanently located, manufactured home or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indi-cated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY Remove any plastic from trim parts before turning the fireplace ON. It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. It is not unusual for your CFM Corporation gas fireplace to give off some odor the first time it is burned. This is due to the manufacturing process. Please ensure that your room is well ventilated -open all windows. It is recommended that you burn your fireplace for at least ten (10) hours the first time you use it. If the optional fan kit has been installed, place the fan switch in the “OFF” position during this time. Locating Your Fireplace Y E A B C Y X D B F LU584-1 Fig. 1 Locating gas fireplace. LU584-1 Locating unit C) **Island 2/4/99 installation djt F) Chase A) Flat on wall B) Cross corner D) *Room divider E) *Flat on wall corner Y) 6” minimum Note (Fig. 1): ** Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent system (X) does not exceed 20’ (6 m). See details in Venting Section. * When you install your fireplace in(D) Room divider or (E) Flat on wall corner positions (Y), a minimum of 6“ (152 mm) clearance must be maintained from the perpendicular wall and the front of the fireplace. 3 DV360/580 Series Direct Vent Gas Fireplace Fireplace Dimensions (Installed as Top Vent) Rough Opening Depth V J P I T Q H V Nailing Flange K W K Recessed S - Rough Opening Width Rough Opening Height U G F R B D C Electrical Access Gas Line Access E L M A G N O Fig. 2 Fireplace specifications and framing dimensions. Ref. A B C D E F G H I J K L M N O P Q R S T U V W 4 2261b DV360 DV580 DV360 41” (1041 mm) 47”vent (1194 mm) Specs - top 1/25/00 41¹⁄₄” djt 37” (940 mm) (1048 mm) (914 mm) 42” (1067 mm) 36” 24¹⁄₂” (622 mm) 28¹⁄₂” (724 mm) 7” (178 mm) 7” (178 mm) 6” (152 mm) 6” (152 mm) 1¹⁄₄” (32 mm) 1¹⁄₄” (32 mm) 19¹⁄₄” (489 mm) 23¹⁄₂” (591 mm) 5¹⁄₂” (140 mm) 5¹⁄₂” (140 mm) 25” (635 mm) 31” (787 mm) 5/8” (16 mm) 5/8” (16 mm) 10³⁄₄” (273 mm) 10³⁄₄” (273 mm) 2” (51 mm) 2” (51 mm) 7⁵⁄₈” (194 mm) 11¹⁄₄” (286 mm) 1⁷⁄₈” (48 mm) 1⁷⁄₈” (48 mm) 7” (178 mm) Dia. 7” (178 mm) Dia. 4” (102 mm) Dia. 4” (102 mm) Dia. Framing Dimensions 38¹⁄₂” (978 mm) 42¹⁄₂” (1080 mm) 41¹⁄₄” (1048 mm) 47¹⁄₄” (1200 mm) 19¹⁄₄” (489 mm) 23¹⁄₂” (597 mm) 62¹⁄₄” (1581 mm) 75” (1905 mm) 44” (1118 mm) 53” (1346 mm) 31³⁄₄” (807 mm) 38” (965 mm) 20010667 DV360/580 Series Direct Vent Gas Fireplace Fireplace Dimensions (Installed as Rear Vent) Rough Opening Depth U I S H U Nailing Flange J V J Recessed R - Rough Opening Width Rough Opening Height T G F Q B Electrical Access P D C Gas Line Access O E K L A G M N Fig. 3 Fireplace specifications and framing dimensions. Ref. A B C D E F G H I J K L M N O P Q R S T U V 20010667 2261a DV360 DV580 DV360 41” (1041 mm) (1194 mm) Specs rear 47” vent 1/25/00 djt 37” (940 mm) 41¹⁄₄” (1048 mm) (914 mm) 42” (1067 mm) 36” 24¹⁄₂” (622 mm) 28¹⁄₂” (724 mm) 7” (178 mm) 7” (178 mm) 6” (152 mm) 6” (152 mm) 1¹⁄₄” (32 mm) 1¹⁄₄” (32 mm) 19¹⁄₄” (489 mm) 23¹⁄₂” (591 mm) 25” (635 mm) 31” (787 mm) 5/8” (16 mm) 5/8” (16 mm) 10³⁄₄” (273 mm) 10³⁄₄” (273 mm) 2” (51 mm) 2” (51 mm) 7⁵⁄₈” (194 mm) 11¹⁄₄” (286 mm) 1⁷⁄₈” (48 mm) 1⁷⁄₈” (48 mm) 31¹³⁄₁₆” (808 mm) 35³⁄₄” (908 mm) 32⁹⁄₁₆” (827 mm) 36⁹⁄₁₆” (928 mm) Framing Dimensions 38¹⁄₂” (978 mm) 42¹⁄₂” (1080 mm) 41¹⁄₄” (1048 mm) 47¹⁄₄” (1200 mm) 19¹⁄₄” (489 mm) 23¹⁄₂” (597 mm) 62¹⁄₄” (1581 mm) 75” (1905 mm) 44” (1118 mm) 53” (1346 mm) 31³⁄₄” (807 mm) 38” (965 mm) 5 DV360/580 Series Direct Vent Gas Fireplace Clearance to Combustibles Top of unit to ceiling ................................. 36” (914 mm) Front of unit to combustibles ................... 36” (914 mm) Appliance Top of standoff ....................................... 0” (0 mm) Bottom ..................................................... 0” (0 mm) Side ......................................................... 0” (0 mm) Back ........................................................ 0” (0 mm) Venting Concentric sections of DV Vent ................... 1” (25 mm) Nonconcentric sections of DV Vent Sides and bottom .................................. 1” (25 mm) Top ........................................................ 2” (51 mm) Mantels The height that a combustible mantel is fitted above the fireplace is dependent on the depth of the mantel. This also applies to the distance between the mantel leg (if fitted) and the fireplace. J Black Surround Face CFM164a I H G Mantel Leg Side of Combustion Chamber M N O CFM164a Mantel Leg Chart 06/22/01 sta F K L For the correct mounting height and widths, refer to Figures 4a, 4b and the Mantel Chart below. The distances and reference points are not affected by the fitting of a bay window front trim kit. Noncombustible mantels and legs may be installed at any height and width around the appliance. When using paint or lacquer, it must be heat resistant to prevent discoloration. Ref. F G H I J V W X Y Z A B C D CFM170 Maintain minimum 3/4” (19 mm) clearance to combustibles E Fig. 4b Combustible mantel leg minimum installation. Hearth A hearth is not mandatory, but is recommended for aesthetic purposes. We recommend a noncombustible hearth which projects out 12” (305 mm) or more from the front of the fireplace. Fireplace Louvre Assembly top Top of Combustion Chamber Bottom of Door Trim Mantel Mantel Leg from Side Leg Depth Ref. of Comb. Opening 10” (254 mm) K 11¹⁄₂” (292 mm) CFM170 DV Builder 8” (203 mm) FrontL 9¹⁄₂” (241 mm) View 6” (152 mm) M 7¹⁄₂” (191 mm) 4” (101 mm) N 5¹⁄₂” (140 mm) 2” (51 mm) O 3¹⁄₂” (89 mm) Cold climate installation recommendation: CFM146 Mantel Chart Mantel CFM146 Shelf Mantel from Top DV Mantel Chart sta Ref. or Breast7/5/01 Plate Ref. of Comb. Chamber Depth V 10” (254 mm) A 19” (483 mm) W 8” (203 mm) B 17” (432 mm) X 6” (152 mm) C 15” (381 mm) Y 4” (101 mm) D 13” (330 mm) Z 2” (51 mm) E 11” (279 mm) When installing this unit against a non-insulated exterior wall or chase, it is mandatory that the outer walls be insulated to conform to applicable insulation codes. Fig. 4a Combustible mantel minimum installation. 6 20010667 DV360/580 Series Direct Vent Gas Fireplace Framing And Finishing C Adjustable Drywall Strip (Nailing Flange) A Check fireplace to make sure it is levelled and properly positioned. B Flange Position A B C To mount the appliance: Choose the location. DV360 (Fig. 5) 1. This unit comes with four (4) flanges pre-mounted on both sides of the fireplace to allow two different drywall thicknesses to be used. Flange “A” is for 1/2” drywall while flange “B“ is for 5/8” drywall. 2. Bend the desired flanges out 90° on both sides of the fireplace. Slide the fireplace into the framed opening until the flanges contact the front surfaces of the framing. Level the unit and secure it firmly in place. Flange Position A B Drywall Depth 1/2” / 13 mm 5/8” / 16 mm Flange Location for Desired Drywall Depth Drywall Depth 1/2” / 13 mm 5/8” / 16 mm 3/4” / 19 mm Adjustable 1/2”, 5/8” & 3/4” Spacing FP1023 Fig. 5a Adjustable drywall strip (nailing flange) for DV580. A DV360 / DV580 Certified To ANSI Z21.88-2005 / CSA 2.33-2005 FP1023 Vented Gas Fireplace Heater side nailing flange B For units: 1/27/00 djt GFDN4L2, GFDE4L2, GFDI4L2, GFDL4L2 GFDN4P0, GFDE4P0, GFDI4P0 Gas Specifications FP1539 Fig. 5 Drywall flange location for DV360. DV580 (Fig. 5a) 1. Nailing flanges are supplied with the fireplace (found on the fireplace hearth). To level the box and secure FP1539 it firmly in place, remove the nailing flanges from flange location the hearth and install at the sides of the fireplace as 12/04 shown in Figure 5a. 2. Screw through the slotted holes in the drywall strip and into pre-drilled holes in fireplace side. Measure from face of fireplace to the face of the drywall strip to confirm the final depth. Final Finishing Noncombustible materials such as brick or tile can be extended over the edges of the face of the fireplace. Do not cover the window frame assembly, any vent, louvre assembly top or louvre assembly bottom. If a Trim Kit is to be installed, brick and tile will have to be installed flush with the side of this appliance. 20010667 MODEL DV360RN DV360RP DV360EN DV360EP DV360RFN DV360RFP DV580RN DV580RP DV580EN DV580EP DV580RFN DV580RFP FUEL Natural Gas Propane Natural Gas Propane Natural Gas Propane Natural Gas Propane Natural Gas Propane Natural Gas Propane GAS CONTROL Millivolt Hi/Lo Millivolt Hi/Lo 24 Volt Hi/Lo 24 Volt Hi/Lo Comfort Control Comfort Control Millivolt Hi/Lo Millivolt Hi/Lo 24 Volt Hi/Lo 24 Volt Hi/Lo Comfort Control Comfort Control MAX. MIN. INPUT INPUT B.T.U.H B.T.U.H. 30,000 18,500 30,000 17,000 30,000 18,500 30,000 20,000 30,000 20,000 30,000 21,000 38,000 26,500 38,000 27,000 38,000 26,500 38,000 27,000 38,000 26,500 38,000 27,000 Gas Inlet and Manifold Pressures Minimum Inlet Pressure Maximum Inlet Pressure Manifold Pressure Natural LP (Propane) 5.5” w.c. 11.0” w.c. 14.0” w.c. 14.0” w.c. 3.5” w.c. 10.0” w.c. 7 DV360/580 Series Direct Vent Gas Fireplace High Elevations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level. For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction. In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m). Gas Line Installation When purging gas line the front glass must be removed. The gas pipeline can be brought in through the right side of the appliance. Knockouts are provided at convenient locations to allow for the gas pipe installation and testing of any gas connection. When using copper or flex connector use only approved fittings. Always provide a union when using black iron pipe so that the gas line can be easily disconnected for burner or fan servicing. (Fig. 6) See the gas specifications for pressure details and ratings. Remote ON/OFF Switch Installation Do not wire the remote ON/OFF wall switch for this gas appliance into a 120v power supply. 1. Thread wire through the electrical knockout located on either side of the unit. Take care not to cut the wire or insulation on metal edges. Ensure the wire is secured and protected from possible damage. Run one end of the gas control valve and the other end to the conveniently located wall switch. 2. Attach the wire to the ON/OFF switch and install switch into receptacle box. Attach cover plate to switch. 3. Connect wiring to gas valve. (Fig. 7) Remote ON/OFF Switch TPTH The gas line connection can be made with properly tinned 3/8” copper tubing, 1/2” rigid pipe or an approved flex connector. Since some municipalities have additional local codes, it is always best to consult your local authority and the CSA-B149.1 installation codes. The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8” test point up stream of the control. TP For USA installations consult the current National Fuel Gas Code, ANSI Z223.1/NFPA 54. 1/2” Gas Supply TH 1/2” NPT x 3/8” Flare Shutoff Valve 3/8” Flex Line (from valve) FP297a Fig. 6 Typical gas supply installation. Always check for gas leaks with a mild soap and water solution applied with a brush no larger than 1” (25 mm). Never FP297A INSTA VENT FREE apply soap and water solution with a spray UVHB26 GAS SUPPLY bottle. Do not use an open flame for leak 7/1/98 testing. FP1218 Fig. 7 Remote switch wiring diagram for R models. Alternate Switch Location The remote switch can be installed on either side of the access door. Mount the switch to the switch bracket provided. Screw the bracket on either side of the frame, line up the screws FP1218 with the prepunched holes. (Fig. 8) Remote switch wiring 8/02 The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or disconnect this or any other gas appliance control from the gas line when pressure testing. FP1024 Fig. 8 Alternate switch location. 8 FP1024 alternate remote switch location 1/27/00 djt 20010667 DV360/580 Series Direct Vent Gas Fireplace EB-1 Electrical Box INSIDE Electrical Box The fireplace, when installed, must be FRONT OF electrically connected and grounded in UNIT accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code. OUTSIDE For USA installations, follow the local codes and the national Electrical Code ANSI/NFPA No. 70. IT F UN It is strongly suggested that the wiring of NT O FP580 FRO the EB-1 Electrical Junction Box be carried Fig. 9 EB-1 receptacle. out by a licensed electrician. FP580 Electronic Gas Control Valve Ensure that the power to the supply line INSTA VENT FREE EB1 JUNCTION BOX has been disconnected before commencThis appliance may be fitted with 11/18/97 a Synetek ignition ing this procedure. module. The EB-1 electrical junction box has been Installation of the remote on/off starter switch or supplied standard on the DV360/580 models to allow wall thermostat on electronic ignition units. for the easy installation of an optional fan kit. 1. Thread the wiring through the holes on the side To connect the EB-1 box to the house electrical supply, panels of the appliance. Take care not to cut the wire follow the steps below. or insulation on metal edges. Route the wire to a 1. Unscrew the retaining screw from the EB-1 base conveniently located receptacle box. plate (Fig. 9) and remove the EB-1 assembly from 2. Attach the wire to the ON/OFF switch and install the the fireplace. switch into the receptacle box. 2. Remove the front cover of the EB-1 box. 3. Remove the plug socket assembly from the EB-1 BLACK L1 box. WHITE L2 4. Feed the supply line in POWER CORD GREEN from the outside through the cable clamp. (Fig. 9) PURPLE 5. Connect black wire of PILOT SENSING the power supply line to PILOT IGNITER the brass screw (polarized) of the socket asYELLOW sembly. 6. Connect the white wire P M of the power line to the O O chrome screw of the socket assembly. 7. Connect the ground wire of the supply line to VALVE the green screw of the CIRCUIT BOARD socket assembly. BLUE 8. Refit the socket assemORANGE bly back into the electriRED cal box and replace the ON/OFF SWITCH OR cover plate. Secure the WHITE WALL THERMOSTAT cable with the clamp on FP1571 the outside of the unit to prevent strain on the Fig. 10 SIT822 Valve with Synetek electronic control wiring diagram. connections. 9. The EB-1 electrical junction box is now ready to supply power to the FK12 or FK24 fan kits if fitted. 20010667 FP1571 SIT822 Synetek wiring 4/05 9 DV360/580 Series Direct Vent Gas Fireplace Optional Top Vent Application The DV360/580 fireplace is shipped as a rear vent unit. If the layout requires a top vent, convert the unit following the steps below. 1. Remove the 10 screws securing outer collar adapter to fireplace. (Fig. 11) 2. Set outer collar adapter aside. 3. Remove insulation from top of unit and discard. Remove the four (4) screws securing flue cover to top of unit and remove flue cover. (Fig. 12) 4. Remove the four (4) screws securing flue pipe to back of unit. Remove flue pipe. (Fig. 12) 5. Secure flue cover to back of flue outlet. Be sure to replace gasket. (Fig. 14) 6. Install flue pipe and gasket removed in step 4 to top of unit with four (4) screws. Be sure to replace gasket. (Fig. 14) 7. Secure outer collar adapter to unit with the round collar on top, secure with 10 screws. NOTE: Be sure not to damage any gasket material. CAUTION: Remove insulation. Insulation extends beyond opening in top of unit. Be sure to remove all insulation before completing conversion. Insulation measures 9¹⁄₄” x 22³⁄₄” (23.5 cm x 57.8 cm). If the unit is converted back to a rear vent, the insulation (Part number 20003129) must be replaced. Flue Pipe Replace Screws (4) Replace Screws (4) Flue Cover FP1028 Fig. 13 Replace flue cover and flue pipe. Outer Collar Adapter DVT584-604 Outer Collar Adapter Flue Pipe 3/11/99 djt Flue Pipe Remove Screws (5) Remove Screws (5) FP1030 Fig. 11 Remove screws from outer collar adapter. Insulation Flue Cover Flue Pipe FP1030 Outer Collar Adapter Flue Pipe 2/16/00 djt Remove Screws (4) Remove Screws (4) FP1031 Fig. 14 Complete conversion. After conversion to top vent configuration, the 4” (102 mm) flue pipe should be conFP1031 centric within the 7” (175 mm) outer collar. Outer Collar Adapter Flue Pipe completed 2/16/00 djt FP1027 Fig. 12 Remove flue cover and flue pipe. 10 FP1027 DV360/580 Outer Collar Adapter Flue Pipe 1/27/00 djt 20010667 DV360/580 Series Direct Vent Gas Fireplace General Venting Your fireplace is approved to be vented either through the side wall, or vertical through the roof. • • • • Only CFM Corporation venting components specifically approved and labelled for this fireplace may be used. Venting terminals shall not be recessed into a wall or siding. Horizontal venting which incorporates the twist lock pipe must be installed on a level plane without an inclining or declining slope. Horizontal venting which incorporates the use of flex venting shall have an inclining slope from the unit of 1” (25 mm) per 24” (610 mm). 20010667 There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24” (610 mm) from the front of the termination hood. Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area. Location of Vent Termination It is imperative the vent termination be located observing the minimum clearances as shown on following page. 11 DV360/580 Series Direct Vent Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL G V H A N N D L V E C B V F B ����� ������ Ope V B Operable B V V Fixed Closed B J X X AIR SUPPLY INLET M I A CFM145a V VENT TERMINATION B V rable C = Clearance to permanently closed window D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2’ (610mm) from the center line of the terminal E = Clearance to unventilated soffit F = Clearance to outside corner G = Clearance to inside corner (see next page) H = Clearance to each inside of center line extended above meter/regulator assembly K X AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installations1 A = Clearance above grade, veranda, porch, deck, or balcony B = Clearance to window or door that may be opened V CFM145a 12” (30cm) DV Termin Location 5/01/01 Rev. 12/05/01 sta 6” (15cm) for appliances < 10,000Btuh (3kW), 12” (30cm) for appliances > 10,000 Btuh (3kW) and < 100,000 Btuh (30kW), 36” (91cm) for appliances > 100,000 Btuh (30kW) US Installations2 12” (30cm) 12” (305mm) recommended to prevent window condensation 6” (15cm) for appliances < 10,000 Btuh (3kW), 9” (23cm) for appliances > 10,000 Btuh (3kW) and < 50,000 Btuh (15kW), 12” (30cm) for appliances > 50,000 Btuh (15kW) 12” (305mm) recommended to prevent window condensation 18” (458mm) 18” (458mm) 12” (305mm) see next page see next page 3’ (91cm) within a height of 15’ (5m) above the meter/regulator assembly 12” (305mm) see next page see next page 3’ (91cm) within a height of 15’ (5m) above the meter/regulator assy 3’ (91cm) 6” (15cm) for appliances < 10,000 Btuh (3kW), 9” (23cm) for appliances > 10,000 Btuh (3kW) and < 50,000 Btuh (15kW), 12” (30cm) for appliances > 50,000 Btuh (15kW) 3’ (91cm) above if within 10 feet (3m) horizontally 7’ (2.13m)† I = Clearance to service regulator vent outlet J = Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliances 3’ (91cm) 6” (15cm) for appliances < 10,000 Btuh (3kW), 12” (30cm) for appliances > 10,000 Btuh (3kW) and < 100,000 Btuh (30kW), 36” (91cm) for appliances > 100,000 Btuh (30kW) K = Clearance to a mechanical air supply inlet 6’ (1.83m) L = Clearance above paved sidewalk or paved 7’ (2.13m)† driveway located on public property M = Clearance under veranda, porch, deck or 12” (30cm)‡ 12” (30cm)‡ balcony N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450mm). 1 In accordance with the current CSA-B149 Installation Codes 2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes † A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings ‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: NOTE: 1. Local codes or regulations may require different clearances. 2. The special venting system used on Direct Vent Fireplaces are certified as part of the appliance, with clearances tested and approved by the listing agency. 3. CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements. Fig. 15 Vent termination locations. 12 20010667 DV360/580 Series Direct Vent Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner G= Combustible 6" (152 mm) G F= Combustible 6" (152 mm) Noncombustible 2" (51 mm) V Noncombustible 2" (51 mm) V C V E O F Balcony with perpendicular side wall Balcony with no side wall D C E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.4 m) Min. M M V V P M= Combustible & Noncombustible 12" (305 mm) Combustible & Noncombustible M = 24" (610 mm) P = 20” (508 mm) No. of Caps 1 2 3 4 DMin. 3’ (.9 mm) 6’ (1.8 m) 9’ (2.7 m) 12’ (3.7 m) CMax. 2 x DActual 1 x DActual 2/3 x DActual 1/2 x DActual DMin. = # of Termination caps x 3 CMax. = (2 / # termination caps) x DActual 584-15 *NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap. Fig. 16 Termination clearances. General Information Assembling Vent Pipes Canadian Installations The venting system must be installed in accordance with the current CSA-B149.1 installation code. USA Installations The venting system must conform to local codes and/or the current National Fuel Code ANSI Z223.1/NFPA 54. Only venting components manufactured by CFM Corporation may be used in Direct Vent systems. * Be sure the vent is actually crushed before proceeding. Apply a tug to be sure the vent will not slip off the collars. Repeat process with 7” flex vent pipe. The same procedure must be performed on the vent side. Apply High Temperature Sealant Flex Vent Pipes Before joining the flex vent pipe to the unit, apply a bead of high temperature sealant* (provided) to the 4” pipe exiting the fireplace. Secure flex vent piep in place with a hose clamp (provided). *Be sure the flex pipe overlaps at least 1” (25mm) onto the collars of the fireplace and termination. If the termination has an internal bead, be sure to overlap and secure 1” (25 mm) past the bead. 20010667 Hose Clamp FP1471 Fig. 17 Apply high temperature sealant to 4” and 7” pipes. 13 DV360/580 Series Direct Vent Gas Fireplace Twist Lock Pipes 30 When using twist lock pipe it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the sliding joints of any telescopic vent section used in the system. 29 28 Vertical dimension form the floor of the unit to the center of the horizontal vent pipe 27 To join twist lock pipes together, simply align the beads of the male end with the grooves of the female end, twisting the pipe until the flange on the female end contacts external flange on the male end. It is recommended that you secure the joints with three (3) sheet metal screws, however, this is not mandatory with twist lock pipe. (Fig. 18) To make it easier to assembly the joints, we suggest putting a lubricant (Vaseline or similar) on the male end of the twist lock pipe prior to assembly. Male End Female End 26 25 24 23 22 21 20 19 18 17 16 15 14 13 eg: A 12 11 10 9 8 7 eg: B 6 5 4 Screw Holes 3 TWL100 Fig. 18 Twist-lock pipe joints. 3 1. Determine the height of the center of the horizontal vent pipe exiting through the outer wall. Using this dimension on the Sidewall Vent Graph (Fig. 19), locate the point intersecting with the slanted graph line. 2. From the point of this intersection, draw a vertical line to the bottom of the graph. 3. Select the indicated dimension, and position the fireplace in accordance with same. 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Fig. 19 Sidewall venting graph. (Dimensions in feet) Refer to Page 20 for venting requirements for snorkels. Rear Wall Vent Application When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance. • EXAMPLE A: If the vertical dimension from the floor of the unit is 11’ (3.4m) the horizontal run to the face of the outer wall must not exceed 14’ (4.3m). • EXAMPLE B: If the vertical dimension from the floor of the unit is 7’ (2.1m), the horizontal run to the face of the outer wall must not exceed 8¹⁄₂’ (2.6m). • • 14 5 6 Horizontal dimension from the outside face of the wall to the center of the fireplace vent flange How to Use the Vent Graph TWL100 The Vent Graph should be read in conjunction with the Twist Lock Pipe following vent installation instructions to determine the 3/12/99 djt relationship between the vertical and horizontal dimensions fo the vent system. 4 Only CFM Corporation venting components are approved to be used in these applications (See ‘Venting Components’ listed for different installation requirements). The maximum horizontal distance between the rear of the appliance (or end of the transition elbow in a corner application) and the outside face of the rear wall is 20” (508mm). (Fig. 20, 21) Only one 45° elbow is allowed in these installations. Minimum clearances between vent pipe and combustible materials are as follows: Top - 2” (51 mm) Sides - 1” (25 mm) Bottom - 1” (25 mm) 20010667 DV360/580 Series Direct Vent Gas Fireplace Vent Opening for Combustible Walls 9³⁄₈” (240 mm) 20” (508 mm) Max. Rear Vent Top View 10³⁄₈” (265 mm) DVR584-600 20” DVR584-600 (508 mm) Max. vent no Rear 2/99 djt Framing Detail Fireplace Hearth Fig. 20 Rear vent application, no elbows. 20” (508 mm) Max. Opening for Noncombustible Wall elbows 7¹⁄₂” (190 mm) 45° 45° Fireplace Hearth VO584-100 Fig. 22 Locate vent opening on wall. Rear Vent Top View, Corner Installation FP836 Adjustable Zero Clearance Sleeve Fig. 21 Rear vent application, one 45° elbow. FP836 Rear Wall Vent Installation Vent-Top View Twist LockRear Pipe 11/21/98 VO584-100 Vent Opening 2/99 djt Max. Length 12” (305 mm) #8 Screws (2) #8 Screws (2) #8 Screws (2) Step 1 Locate and cut the vent opening in the wall. For combustible walls first frame in opening. (Fig. 22) NOTE: When using flex vent, the opening will have to be measured according to the 1” (25mm) rise in 24” (610mm) vertical run. Combustible Walls: Cut a 10³⁄₈”H x 9³⁄₈” W (265 mm x 240 mm) hole through the exterior wall and frame as shown. (Fig. 22) Noncombustible Walls: Hole opening should be 7¹⁄₂” (191mm) diameter. Zero clearance sleeve is only required for combustible walls. Step 2 Measure wall thickness and cut zero clearance sleeve parts to proper length (Maximum 12” / 305 mm). Assemble sleeve to its maximum opening (10³⁄₈” x 9³₈”) and attach to firestop assembly. (Fig. 23) Step 3 Measure the horizontal length requirement for the venting including a 2” (51 mm) overlap, i.e. from the elbow to the outside wall face plus 2” (51 mm). (Fig. 21) 20010667 Firestop Adjustable Zero Clearance Sleeve ZCS101 Fig. 23 Adjustable ZCS101 zero clearance sleeve. Step 4 Zero Clearance Sleeve 3/11/99 djt Install the 4” (102 mm) vent to the appliance collar and secure with 3 sheet metal screws. Install the 7” (178 mm) vent pipe to the appliance collar and secure with 3 sheet metal screws. It is not necessary to seal this connection. If a 45° elbow is being used attach the elbow to the appliance in the same manner then attach the venting to the elbow. It is critical that there is no downward slope away from the appliance when connecting the vent or elbow. Step 5 Guide the venting through the vent hole as you place the appliance in its installed position. Guide the 4” (102 mm) and 7” (178 mm) collar of the vent termination into the outer ends of the venting. Do not force the termination. If the vent pipes do not align with the termination, remove and realign the venting at the appliance flue collars. (Fig. 24) Attach the termination to the wall as outlined in the instruction sheet supplied with the termination. 15 DV360/580 Series Direct Vent Gas Fireplace Finished Wall Rise Vent Termination FP1472 Fig. 26 There must be a 1/2” rise per foot length. Vertical Sidewall Application FP1005 Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations FP1472apply and must be strictly as to vent configurations rise in length adhered to. 4/04 djt The Vent Graph, showing the relationship between vertical and horizontal side wall venting, will help to determine the various dimensions allowable. Fig. 24 Side view of final unit location. Rear WallFP1005 Vent Installations Side View Vent Termination Flex Vent Pipe Minimum clearance between vent pipes and combustible materials is one inch (25 mm) on top, bottom and sides unless otherwise noted. 1/25/00 djt Follow Steps 1 and 2 on Page 15. Step 3 Install the 4” (102 mm) flex vent pipe to the appliance collars described in “General Information Assembling Vent Pipes”, Page 12. If the installation requires a 45° angle, grasp the vent pipe close to the appliance collar and bend to 45°. DO NOT exceed 45°. (Fig. 25) Install the 7” vent pipe in the same manner as Step 2. Termination When vent termination exits through foundations less than 20” (508 mm) below siding outcrop, the vent pipe must flush up with the siding. It is best to locate the fireplace in such a way that minimizes the number of offsets and horizontal vent length. The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace (or the top of the Transition Elbow) to the face of the outer wall. Horizontal plane means no vertical rise exists on this portion of the vent assembly. Flex Section Appliance Collars When installing the appliance as a rear vent unit, the 90° or 45° Transition Elbow attached directly to the rear of the unit is NOT INCLUDED in the following criteria and calculations, and unless specifically mentioned should be ignored when calculating venting layouts. • FP1473 Fig. 25 Grasp the vent pipe close to the collar and bend to 45° angle. Do not exceed 45°. NOTE: There must be a 1/2” (13 mm) rise in a 12” (305 mm) length of flex vent. • The maximum number of 90° elbows per side wall installation is three (3). (Fig. 27) If a 90° elbow is fitted directly on top of the fireplace flange the maximum horizontal vent run before the termination or a vertical rise is 36” (914 mm). (Fig. 28) Step 4 Assemble the flex vent to the collars on the termination FP1473 as you did on the appliance. corner flex install 4/04 djt 16 20010667 DV360/580 Series Direct Vent Gas Fireplace 7’ (2.1 m) 3 x 90° Elbows 3 x 90° Elbows A FP1176 10’ (3 m) B 8’ (2.4 m) Fig. 27 Maximum three (3) 90° elbows per installation. 36" (914mm) Max. 36" (914mm) Max. V584-201 Fig. 30 Maximum vent run with elbows. In Figures 29 & 30, dimension V584-201 A plus B must not be greater than 17’ (5.2m) Horizontal Run 2/99 djt The maximum number of 45° elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run. • For each 45° elbow installed in the horizontal run, the length of the horizontal run MUST be reduced by 18” (457 mm). This does not apply if the 45° elbows are installed on the vertical part of the vent system. • The maximum number of elbow degrees in a system is 270°. (Fig. 31) Example: Elbow 1 = 90° Elbow 2 = 45° Elbow 3 = 45° Elbow 4 = 90° Total angular variation = 270° • FP1177 Fig. 28 Maximum horizontal run with no rise. • If a 90° elbow is used in the horizontal vent run (level height maintained) the horizontal vent length is reduced by 36” (914 mm). (Fig. 29, 30) This does 20" are used to increase or not apply if the 90°Max elbows redirect a vertical rise. (Fig. 27) Example: According to the vent graph (Page 14) the maximum horizontal vent length in a system with a 7¹⁄₂’ (2.3 m) rise is 20’ (6 m) and if a 90° elbow is required in the horizontal vent it must be reduced to 17’ (5.2 m). B Max 20" A 1 2 A + B = 17' (Max.) (5.2m) 3 4 1 2 3 4 7'6" (2.3m) FP1178 1 + 2 + 3 + 4 = 270° Fig. 31 Maximum elbow usage. FP1180 Fig. 29 Horizontal run reduction. 20010667 17 DV360/580 Series Direct Vent Gas Fireplace Vertical Sidewall Installation Twist Lock Pipe Max. Length 12” (305 mm) Adjustable Zero Clearance Sleeve Step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size. (Fig. 32) (For combustible walls first frame in opening.) NOTE: When using flex vent, the opening will have to be measured according to the 1/2” (13 mm) rise in 12” (305 mm) vent run. Combustible Walls: Cut a 9³⁄₈”H x 9³⁄₈”W (240 mm x 240 mm) hole through the exterior wall and frame as shown. (Fig. 32) Noncombustible Walls: Hole opening must be 7¹⁄₂” (191mm) in diameter. Vent Opening for Combustible Walls #8 Screws (2) #8 Screws (2) #8 Screws (2) Firestop Adjustable Zero Clearance Sleeve X 9³⁄₈” (240 mm) ZCS101 Fig. 33 Adjustable ZCS101 zero clearance sleeve. Zero Clearance Sleeve 3/11/99 djt X 9³⁄₈” (240 mm) FP1181 Fireplace Hearth Framing Detail Fig. 34 Vertical height requirements. Step 4 Opening for Noncombustible Wall 7¹⁄₂” (190 mm) Fireplace Hearth VO584-100 Fig. 32 Locate vent opening on wall. Step 2 Measure wall thickness and cut zero clearance sleeve VO584-10012” / 305 mm). parts to proper length (MAXIMUM Vent Opening Assemble sleeve and attach to firestop with #8 sheet 2/99 djtfirestop assembly. (Fig. metal screws (supplied). Install 33) Zero clearance sleeve is only required for combustible walls. Step 3 Place fireplace into position. Measure the vertical height (X) required from the base of the flue collars to the center of the wall opening. (Fig. 34) 18 Apply a band of silicone to the inner and outer flue collars of the fireplace and using appropriate length of pipe section(s) attach to fireplace with three (3) screws. Follow with the installation of the inner and outer elbow, again secure joints with three (3) sheet metal screws. Wipe off any excess high temperature sealant. Step 5 Measure the horizontal length requirement including a 2” (51mm) overlap, i.e. from the elbow to the outside wall face plus 2” (51mm) (or the distance required if installing a second 90° elbow). (Fig. 35) Always install horizontal venting on a level plane. Step 6 Use appropriate length of pipe sections - telescopic or fixed - and install. The sections which go through the wall are packaged with the starter kit, and can be cut to suit if necessary. Sealing vent pipe and firestop gaps with high temperature sealant will restrict cold air being drawn in around fireplace. 20010667 DV360/580 Series Direct Vent Gas Fireplace X 4” Flex Vent Pipe 12" (305mm) X Spacer Spring 6" (152mm) 5" (127mm) 6³⁄₄" (172mm) FP1182 FP1474 Fig. 36 Install spacer springs. Fig. 35 Horizontal length requirement. Step 4 Step 7 Apply high temperature sealant to 4” (102 mm) and 7” (178 mm) collars or the termination one inch away from crimped end. Guide the vent terminations 4” and 7” collard into their respective vent pipes. Double check that the vent pipes overlap the collars by 2” (51 mm). Secure the termination to the wall with screws provided and caulk around the wall plate to weatherproof. As an alternative to screwing the termination directly to the wall, you may also use expanding plugs or an approved exterior construction adhesive. You may also attach the termination with screws through the inner body into the 4” vent pipe, however for this method, you must extend the 4” pipe approximately 6” (152 mm) beyond the outer face of the wall. Support horizontal pipes every 36” (914 mm) with metal pipe straps. Install the 4” (102 mm) flexFP1474 vent pipe to the appliance collar as described on Page 13. Secure spacer springsthe end with the first spring 6³⁄₄” (172 mm) 4/04 from the djt flex pipe end to the unit. Step 5 Slide the 7” (178 mm) flex vent pipe over the 4” flex vent pipe and secure the 7” collar as described on Page 13. Step 6 Bend the flex pipe horizontal so the bottom of the horizontal pipe measure 6¹⁄₂” (165 mm) from the top of the unit immediately after the 90° formation. (Fig. 37) Be sure to follow the 1/2” (13 mm) rise in a 12” (305 mm) horizontal run rule. Step 7 Install the 4” flex then 7” flex to the termination. Vertical Sidewall Installation Flex Vent Pipe NOTE: The 40” (1016 mm) flex vent is used for 90° off the top of the unit then out the back wall. Follow Step 1 and 2 on Page 18. 6¹⁄₂" (165mm) Step 3 Install the four (4) spacer springs on the 4” flex vent pipe. When installing the spacer springs around the 4” pipe, stretch the spring to approximately 15” (381 mm), wrap the spring around the pipe and interlock the ends of the spacer spring approximately 2” (51 mm). Measure 6³⁄₄” (172 mm) from the end of the pipe. Place the next spring 5” (127 mm) from the previously installed spring. Place the next spring 6” (152 mm) from the last spring. Finally place the last spring 12” (305 mm) from the last spring installed. (Fig. 36) 20010667 FP1475 Fig. 37 Bend flex vent at 90° so horizontal portion is 6¹⁄₂” (165 mm) off top of unit. FP1475 flex 90 bend 4/04 djt 19 DV360/580 Series Direct Vent Gas Fireplace Do not back fill around snorkel. Below Grade Installation When it is not possible to meet the required vent terminal clearances of 12” (305 mm) above grade level, a snorkel kit is recommended. It allows installation depth down to 7” (178 mm) below grade level. The 7” (178 mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall. Ensure the sidewall venting clearances are observed. If venting system is installed below ground, we recommend a window well with adequate and proper drainage to be installed around the termination area. A clearance of at least 4” must be maintained between the snorkel and the soil. If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first, then secure to snorkel with self drilling #8 x 1/2 sheet metal screws. It will be necessary to extend vent pipes out as far as the protruding wall face. (Fig. 39) If installing a snorkel, a minimum 24” (610 mm) vertical rise is necessary. The maximum horizontal run with the 24” vertical pipe is 36” (914 mm). This measurement is taken from the collar of the fireplace (or transition elbow) to the face of the exterior wall. See the Sidewall Venting Graph for extended horizontal run if the vertical exceeds 24” (610 mm). 1. Establish vent hole through the wall (Fig. 32) 2. Remove soil to a depth of approximately 16” (406mm) below base of snorkel. Install drain pipe. Install window well (not supplied). Refill hole with 12” (305 mm) of coarse gravel leaving a clearance of approximately 4” (102 mm) below snorkel. (Fig. 38) 3. Install vent system. 4. Ensure a watertight seal is made around the vent pipe coming through the wall. 5. Apply high temperature sealant caulking (supplied) around the 4” and 7” snorkel collars. 6. Slide the snorkel into the vent pipes and secure to the wall. 7. Level the soil so as to maintain a 4” (102 mm) clearance below snorkel. (Fig. 38) Zero Clearance Sleeve (if required) Screws 7TDVSNORK (Snorkel) Firestop 4” (102mm) Clearance Min. 7” Pipe Window Well 24” (610mm) Minimum* Snorkel Foundation Recess Watertight Seal Around PIpe Sheet Metal Screws BG401 Fig. 39 Snorkel installation, recessed foundation. BG401 Vertical Through-the-Roof Application Snorkel This gas fireplace has been approved for: 2/10/99 • Vertical installations updjt to 40’ (12 m) in height. Up to a 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. (Fig. 40) • Up to two 45° elbows may be used within the horizontal run. For each 45° elbow used on the horizontal plane, the maximum horizontal length must be reduced by 18” (450 mm). Example: Maximum horizontal length: No elbows = 10’ (3 m) 1 x 45° elbow = 8.5’ (2.6 m) 2 x 45° elbows = 7’ (2.1 m) • • • Gravel Drain • Foundation Wall *A minimum of 24” (610 mm) vertical pipe must be installed when using the 7TDVSNORK Kit. Wall Screws • A minimum of an 8’ (2.5 m) vertical rise is required. Two sets of 45° elbow offsets may be used within the vertical sections. From 0 to a maximum of 8’ (2.5 m) of vent pipe can be used between elbows. (Fig. 41) 7DVCS supports offsets. (Fig. 43) This application will require that you first determine the roof pitch and use the appropriate starter kit. (Refer to Venting Components List) The maximum angular variation allowed in the system is 270°. (Fig. 41) The minimum height of the vent above the highest point of penetration through the roof is 2’ (610 mm). (Fig. 44) Refer to note 2, Page 14. BG402a Fig. 38 Below grade installation. 20 BG402a Top Vent 20010667 DV360/580 Series Direct Vent Gas Fireplace Vertical Through-the-Roof Installation Max. Height 40’ (12.2 m) Min. Height 8’ (2.4 m) Max. 10’ (3 m) Support Straps Every 3’ (.9 m) Max. Height 40’ (12.2 m) Min. Height 8’ (2.4 m) Max. 10’ (3 m) FP1183 Fig. 40 Support straps for horizontal runs. Attic Insulation Shield 1 + 2 + 3 + 4 = 270° 1 2 3 4 1. Locate your fireplace. 2. Plumb to center of the (4”) flue collar from ceiling above and mark position. 3. Cut opening equal to 9³⁄₈” x 9³⁄₈” (240 mm x 240 mm). 4. Proceed to plumb for additional openings through the roof. In all cases, the opening must provide a minimum of 1 inch clearance to the vent pipe, i.e., the hole must be at least 9³⁄₈” x 9³⁄₈” (240 mm x 240 mm). 5. Place fireplace into position. 6. Place firestop(s) #7DVFS or Attic Insulation Shield #7DVAIS into position and secure. (Fig. 42) 7. Install roof support (Fig. 43) and roof flashing making sure upper flange is below the shingles. (Fig. 45) 8. Install appropriate pipe sections until the venting is above the flashing. (Fig. 45) 9. Install storm collar and seal around the pipe. 10. Add additional vent lengths for proper height. (Fig. 45) 11. Apply high temperature sealant to 4” and 7” collars of vertical vent termination and install. If there is a room above ceiling level, fire stop spacer must be installed on both the bottom ad the top side of the ceiling joists. If an attic is above ceiling level a 7DVAIS (Attic Insulation Shield) must be installed. The enlarged ends of the vent section always face downward. 1 Upper Floor 2 3 11” (279 mm) 4 11” (279 mm) Ceiling Installation FP1179 Joist Fig. 41 Maximum elbow usage. Firestop Spacer Nails (4) FP1029 Fig. 42 Place firestop spacer(s) and secure. 20010667 FP1029 attic insulation shield firestop spacers 1/28/00 djt 21 DV360/580 Series Direct Vent Gas Fireplace Typical Roof Support Application Typical Ceiling Support Application 3 #5 Sheet Metal Screws per Joint Sealant FP1184 Storm Collar Fig. 43 Venting supports. FP1184 Typical roof/ceiling support apps. Min. 2' (610 mm) TWL101a Fig. 45 Roof flashing. TWL101a Twist Lock Pipe 2/8/99 djt FP1185 Fig. 44 Minimum termination to roof clearance. 22 20010667 DV360/580 Series Direct Vent Gas Fireplace Venting Components 7TDVRVT - Through the wall Rear Vent Termination 584A venting components rear vent term 4/6/99 djt 584B Vent components Starter Kit 2/25/99 djt 584C Vent components 584D 45 degree elbow Vent Components 2/25/99 90 degree djt elbow 10/20/99djttwistlock 584E 2/25/99 Venting Components 10/20/99 twist lock Telescope vent 584F 2/25/99Components djt Venting 10/20/99 twist lock Pipe sections 2/25/99 djt 10/20/99 twist lock 584G Venting Components Firestop spacer 2/25/99 djt 20010667 584H Venting components attic insulation shield 2/25/99 djt 584I vent components offset support 2/25/99 djt Starter Kit Model 7TDVSK - Sidewall Venting (Twist Lock Pipe) Model 7FDVSK - Sidewall Venting (Flex Vent Pipe) Models 7TDVTK/TV - Hot Touch Termination Kits Model 7TDVTVTK/TV - Cool Touch Termination Kit Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDVSKV-F order flat roof Starter Kit for Below Grade Installation Model 7TDVSKS -Snorkel Kit (Twist Lock Pipe) Model 7FDVSKS -Snorkel Kit (Flex Vent Pipe) Starter Pipe Model 7TDVP 20/8 - 24” Starter Pipe Bulk Model 7FDVP 30/8 - 30” Flex Pipe Bulk 45o Elbow 7TDV45 for Rear Vent to Vertical Vent or Vertical/Horizontal Offsets 90o Transition Elbow 7TDVRT90 for Rear Vent to Vertical Vent 90° Elbow 7TDV90 Vertical/Horizontal Offset Telescopic vent sections 7TDVP1117 -11” to 17” adjustable length 7TDVP3567 -35” to 67” adjustable length Pipe sections for vertical or horizontal venting Model 7TDVP8” 4 per box Model 7TDVP12” 4 per box Model 7TDVP24” 4 per box Model 7TDVP36” Model 7TDVP48” Firestop Spacer Model 7DVFS Attic Insulation Shield Model 7DVAIS Vertical/Horizontal Combination Offset Support Model 7DVCS 23 DV360/580 Series Direct Vent Gas Fireplace Operating Instructions Window Frame Assembly Glass Information Only glass approved by CFM Corporation should be used on this fireplace. • • • Fireplace Front • The use of any non-approved replacement glass will void all product warranties. Care must be taken to avoid breakage of the glass. Do not operate appliance with glass front removed, cracked or broken. Replacement glass (complete with gasket) is available through your CFM Corporation dealer and should only be installed by a licensed qualified service person. Clamps Glass Panel Glass Panel Pull Clamp Hook Push Clamp FP771a Handle Louvre Removal To remove louvre assembly top, pull louvre up and then lift out. The louvre assembly bottom is hinged at the bottom edge and swings down. (Fig. 46) Fig. 47 Window frame assembly removal. 2. 1. Louvre ed). After the initial cleaning process the glass should FP771a be cleaned two or three times during each operating DV360/580 GLASS REMOVAL-CLIP season depending on the environment in the house. 1/27/00 djt Clean the glass after the first two weeks of operation. Do not clean glass when hot. Glass Panel Do not use abrasive cleaners. FP444 Window Fig. 46 Remove louvre assembly top. FP444 remove louvre Removal Frame Assembly 12/99 1. Turn the fireplace OFF (including the pilot). 2. If the unit has been operating, allow time for the components to cool. 3. Remove louvre assembly top. 4. Open the louvre assembly bottom. 5. Release the two clamps along lower edge of the frame by pulling down on clamp handles. (Fig. 47) 6. Tilt window frame assembly out slightly at the bottom, lift the frame up and away from the fireplace. 7. To replace window frame assembly reverse procedure. Glass Cleaning It is necessary to clean the glass periodically. During start-up condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended the glass be cleaned two or three times with a non-ammonia household cleaner and warm water (gas fireplace glass cleaner is recommend24 Do not strike or slam the glass. Installation of Optional Ceramic Panels DV360 1. Remove glass. 2. Remove glass heat shield located at the top of the firebox toward the front. 3. Place the rear panel behind the rear log bracket. 4. Slide the right and left panels into place, The right and left panels will hold the rear panel in place when positioned properly. 5. Replace the glass heat shield. 6. Place the right and left hearth refractories and bring them together in the center and slide towards the front of the unit. Replacement of Ceramic Hearth Panels 1. Remove glass. 2. Set left and right panels on hearth and bring towards front of unit. 20010667 DV360/580 Series Direct Vent Gas Fireplace Screw Screw Burner Log Identification Chart Logs Log Front Left Log Front Right Log Rear Log Top Left Log Top Right Log Front Center Log Top Center Log Overlay Grate Hearth Panels Front of Unit H100a Fig. 48 Hearth panel location. H100a hearthofPanels Installation Logs 1/27/00 djt Remove front glass. (Refer to “Window Frame Assembly Removal” Section, Fig. 47) Remove logs from packaging. As with all plastics — these are not toys and should be kept away from children and infants. DV360 20010673 20010672 20010675 -20010676 -20010677 20010674 DV580 E9 E10 E8 E12 E13 E11 --- DV360 NOTE: Refer to Figure 49 for bracket and bend locations. 1. Place the log front right. Hold the log with the pointed end toward the left. Place on top of burner toward the right. Slide the log toward the front until it comes in contact with the bracket at the front of the burner housing behind the burner tube. (Fig. 49) Adjust the log until the pointed end on the left is aligned with the left edge of the bracket. (Fig. 50) NOTE: Gently push down on the right rear of the log so the pilot front shield cuts slightly into the log. This will help to ensure proper log position. Left Edge of Bracket Pilot Front Shield Stop Bracket Rear Log Bracket Pilot Bracket Bend Front Left Bend Front Brackets FP1653 Fig. 49 Burner brackets and bends. Figure 50 Log Front Right ������ ������������ ���� LG477 Front Brackets 20010667 ������ ��������������������� ���� 25 DV360/580 Series Direct Vent Gas Fireplace 2. Place the log overlay. Hold the overlay with the flat side down and large cut out for the middle flame on the right. Set the overlay on top of the burner toward the left front inside the stop bracket on the left end and the bend on the front left of the burner. (Fig. 49) Rotate the right end of the overlay clockwise until it makes contact with the back of the log front right. NOTE: This is very critical as improper positioning of the overlay will affect the flame and the performance of the unit. (Fig. 51) Figure 51 Log Overlay LG478 Log Rear Figure 52 ����� ������������� ���� LG462 Locator Pins Figure 53 ����� ����������������� ���� 3. Place log rear. The rear log sits in the firebox at an angle toward the left over the rear log bracket and the left side of the burner. (Fig. 49) Set the log on the rear log bracket. The notch on the right side will go over the pilot. Swing the left end of the log toward the front until it makes contact with the stop bracket. Slide the log to the right so the pilot notch on the log makes contact with bend on the left of the pilot bracket. (Fig. 52) 4. Place the glowing embers by building them up lightly between the fettle and the burner tube assembly. (Fig. 53) 5. Place the log front left. Set the log by matching the square hole on the bottom with the pins on the overlay. The right side of this log should come in contact with the left andiron. Lay the log at an angle to the left over the fettle. When this log is in place, it must not cover the front left opening of the overlay. (Fig. 54) LG463 Glowing Embers 20010667 26 ����� ������������ DV360/580 Series Direct Vent Gas Fireplace 6. Place the log top center. Hold the log with the pointed end toward Log Rear the back. Match the two holes on the bottom of the log with the two pins on the top of the log front right. (Refer to Figure 53 for pin locations) Set the log and lay it into the rear log. (Fig. 54) 7. Place the log top right. Hold the log with pointed end to the left. Match the two holes on the bottom of the log with the two pins on the rear log and set the fork on the log over the right front log. (Fig. 54) 8. Place the lava rock on the hearth refractory in the front as desired. (Fig. 54) Figure 54 Log Top Right Log Top Center Log Front Right LG464 Lava Rock Log Front Left DV580 Refer to Figure 51. Log Top Left Log Rear (E12) 1. Place rear log (E8) on rear (E8) bracket (ensure the notch on Log Top Right the left end is centered on (E13) the left side of rear bracket), so it will not move from side to side and is firmly posiLog Front ����� tioned on the bracket. Be Left ���������� (E9) sure log is as far forward as Log Front possible on bracket. (Fig. 55) Right ���� (E10) 2. Place front left log (E9) on top of burner, left side. Align log’s bottom holes with left bracket log locator studs. 3. Place front right log (E10) on top of burner, right side. Align log’s bottom holes with right bracket log locator studs. (Fig. 50) 4. Place top left log (E12). Use Burner Lava Rock and log’s bottom hole to locate Log Front 1/3 of the bag of Embers Center (E11) it onto rear log left (E8) and LG395 just rest bottom cut out log onto the grate assembly. Fig. 55 DV580 log, burner lava rock and ember placement. 5. Place top right log (E13). 7. Place large lava rock around the front grate. Use log’s bottom hole to locate it onto rear log right (E8) and the bottom of top right log rest onto front Top logs must be placed properly onto right log (E10). notches. ����� 6. Place front center log (E11). Position the log notch against the center grate assembly and the bottom of ���������� front center log rest onto front right log (E10). ���� 20010667 27 DV360/580 Series Direct Vent Gas Fireplace Flame Characteristics Burner Lava Rock Placement Place burner lava rock on the burner in front of the front logs. Do not place burner lava rock in the inside corners of the front logs. Large Lava Rock The large lava rock provided with this fireplace must be placed on the firebox base around the sides of the burner assembly and on the tray beneath the grate. It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to the illustrations below (Figs. 58, 59). If any of the flames appear abnormal call a service person. PSE Pilot 3/8” - 1/2” (10 - 13 mm) Under no circumstances should this large lava rock be placed on any part of the burner assembly. Flame & Temperature Adjustment Turn counterclockwise to decrease flame height LO For fireplaces equipped with Hi/Lo valves, flame adjustment is accomplished by rotating the Hi/Lo adjustment knob located near the center of the gas control. (Fig. 56 or 57) HI Turn clockwise to increase flame height Fig. 56 Flame adjustment knob for Honeywell valve. HI Turn counterclockwise to increase flame height Turn clockwise to decrease HV102 Honeywell hi/lo knob LO flame height F584-703 SIT Pilot Fig. 58 Correct pilot flame appearance. Inspecting the Venting System This appliance venting system is designed and constructed to develop a positive flow adequate to remove flue gases to the outside atmosphere. Any foreign objects in the venting system, except those F584-703 venting system, may cause designed specifically for theHoneywell spillage of flue gases. & PSE pilot flames To inspect the venting system, make sure the main gas valve is off. Remove window frame assembly (Refer to Window Frame Assembly Removal Section). Using a flashlight, check the area above the baffle in the combustion dome. Clean if necessary. 4/5/99 djt Fig. 57 Flame adjustment knob for SIT valve. FP390 FLAME ADJUSTMENT KNOB 11/21/96 28 20010667 DV360/580 Series Direct Vent Gas Fireplace Yellow Flame Yellow Flame LG444 DV360 Red Glow ����� ��������� ���������� ��������� LG396 DV580 Red Glow Fig. 59 Correct burner flame apperance for DV360 and DV580. ����� ���������������� ���� 20010667 29 DV360/580 Series Direct Vent Gas Fireplace Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any fireplace • Do not touch any electric switch • Do not use any phone in your building • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the Fire Department C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion. D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water. Lighting Instructions 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the ON/OFF switch to “OFF” position or set thermostat to lowest level. 4. Open control access panel. 5. Push in gas control knob slightly and turn clockwise to “OFF”. ON OFF OFF 3 4 5 Euro SIT T LO 3/8" - 1/2" OFF PI ON 1 2 P OFF ilot PILOT 10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8. SIT NOVA Honeywell 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!FP1067 Follow “B” in the safety information above. If you doinstruction not smell gas, go to the lighting knobs next step. 3/9/01 djt 7. Remove glass door before lighting pilot. (See Glass Frame Removal section). 8. Visibly locate pilot by the main burner. 9. Turn knob on gas control counterclockwise to “PILOT”. • If knob does not pop up when released, stop and immediately call your service technician or gas supplier. FP1068 • If after several tries,Lighting the pilotinstructions will not stay lit, turn the gas control knobPilots to “OFF” and call your service technician or gas supplier. 11. Replace glass door. 12. Turn gas control knob to “ON” position. 13. For RN/RP appliances turn the ON/OFF switch to “ON” position or set thermostat to desired setting. 14. Turn on all electrical power to the fireplace. To Turn Off Gas To Heater 1. Turn the ON/OFF switch to Off position or set the thermostat to lowest setting. 2. Turn off all electric power to the fireplace if service is to be performed. 30 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to “OFF”. Do not force. 5. Close control access panel. 20010667 DV360/580 Series Direct Vent Gas Fireplace Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) Warning:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury and loss of life. FOR YOUR SAFETY READ THE FOLLOWING WARNINGS BEFORE LIGHTING THE APPLIANCE A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand. B. BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than the air and will settle on the floor. What to do if you smell gas • Do not try to light any appliance • Do not operate any electrical switch. • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppliers instructions. • If you cannot contact your gas supplier call the Fire Department C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand do not try to repair it, call a qualified service technician. Force or attempting repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and replace any part of the control system and any gas control that has been under water. Lighting Instructions 1. STOP! Read the safety information above before continuing. 2. Turn off all electrical power to the appliance. 3. This appliance is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand. 4. Access the gas control by lowering the lower access door (louvre assembly). LO HI 5. Turn the remote switch, if used, OFF. Turn the wireless remote, if used, OFF. 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP. Follow instructions B in the safety warnings above. If you do not smell gas go onto the next step. 7. Close the access door. 8. Turn ON all electrical power to the appliance. 9. Turn remote switch or wireless remote to “ON”. 10. If the appliance will not operate, follow the instructions TURNING OFF THE GAS TO THE APPLIANCE and call your service technician or gas supplier. Turning Off the Gas to the Appliance 1. Turn the remote switch to the “OFF” position. 2. Turn OFF all electrical power to the fireplace if service is required. 3 Open the lower access panel. 4. Turn the shut-off valve on the flexible gas line to the “OFF” position. 1/2” Gas Supply 1/2” NPT x 1/2” Flare Shut-Off Valve 3/8” Flex Line (From Valve) Valve in the on position FP297A 20010667 31 FP297A INSTA VENT FREE UVHB26 GAS SUPPLY 7/1/98 DV360/580 Series Direct Vent Gas Fireplace Instructions for RF Comfort Control Valve The Comfort Control Valve allows remote control of temperature, fan and flame appearance. NOTE: The antenna should hang in free air away from grounded metal. Operation 1. If the manual switch is in remote position, switch it to LOCAL. (Fig. 60) 2. Turn the pilotstat knob counterclockwise from OFF to the PILOT position, push the knob down, and hold in position. The pilot valve opens and allows gas to flow to the pilot burner. 3. Push plunger on the piezo until the pilot burner is lit. When the pilot burner is lit, the LED on the control will come on after approximately 40 seconds and will be continuously red. When the light turns off which will be approximately 10 seconds after it has been continuously red, the receiver/valve is fully powered. Motor Top Cap Shut Off Procedure If the manual switch is in the REMOTE position, the transmitter can shut off the main burner and fan. However, the control is still on and a command from the transmitter can turn on the main burner or fan. To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The transmitter cannot turn on the main burner or fan. Transmitter Operation Off Mode In the OFF mode, the fireplace flame and fan are off, the display will show OFF and displays the room temperature. If the receiver is in REMOTE mode, the fireplace will shut off. Display Room Temperature Set Temperature Flame Height Level Fan Speed Level Countdown Timer Low Battery Piezo Ignitor Mode Auto On Off OT PIL O • N D LE LOCAL REMOTE Pilostat Knob Fig. 60 Comfort control valve. Down Decreases Flame, Fan Speed Timer or Set Point Fan Plug Antenna FP1039 FP1037 FP1037 4. Release the knob. The shaft will move upward. The Honeywell pilot burner should now stay burning. If the pilot comfort valve burner goes out, repeat step 2. 3/22/00 djt 5. Turn the knob counterclockwise to the ON position. If the manual switch is in the LOCAL position, the main burner will turn on immediately. 6. ON the initial use of a transmitter, a recognition operation is required between the receiver/valve and transmitter. Change the switch from LOCAL to REMOTE. Press the fan or flame button on the transmitter within 30 seconds. The LED will blink indicating the transmitter will now work with the receiver/valve. If the switch continues in the REMOTE position, the transmitter will now control the main valve, flame modulation level and fan control. 7. If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting. The transmitter will control the fan only. 32 Up Increases Flame Height, Fan Speed Timer or Set Point Countdown Timer LED Local/Remote Switch Flame OFF • Fig. 61 Transmitter diagram. On (Manual) Mode FP1039 In the ON mode,comfort the room temperature, flame and fan valve transmitter levels will be shown. MANUAL will appear next to both 3/27/00 the flame and fan icons. djt When the control is in the ON mode, the flame and fan levels, and delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit. 20010667 DV360/580 Series Direct Vent Gas Fireplace Delay Timer Mode Fan Pilot Assembly The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes. Auto Mode Fan Override During Auto Mode If a lower or higher fan speed is desired when operating in the AUTO mode, the fan speed can be overridden by pushing the fan button followed by the up or down key. Pushing a key once will change the fan level by one unit. In this mode “AUTO” is displayed next to the flame icon and “MANUAL” is displayed next to the fan icon. Change Between F/C Temperature Units Push the up and down arrow keys simultaneously for at least 3 seconds to toggle between Fahrenheit and Celsius units. Disable Thermostat Function To disable the thermostat function in the AUTO mode, push the time and down keys simultaneously for at least 3 seconds. To Change Batteries 1. Remove cover on the backside of the transmitter. Install 3 AAA batteries as shown and reattach cover. 2. Once steps 1-3 in OPERATION are completed, receiver/valve and transmitter are now ready. Press any button on transmitter for recognition process to occur between the receiver/valve and transmitter. 3. Use functions as described in TRANSMITTER section. 20010667 Red White FAN In the AUTO mode, the room temperature, set temperature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons. When the control is in the AUTO mode, the main burner will turn on/off or modulate based on the heat needed to maintain the set temperature. The flame level will change automatically to optimize the heat output needed to maintain the set temperature. To change the set temperature, press the up or down key. Pushing a key once will change the temperature by one degree. In the AUTO mode, the fan speed will increase with increasing flame height or decrease with decreasing flame height. “AUTO” is displayed next to the flame and fan icons. Red White White Dots Antenna FP1038 Valve (Bottom View) Fig. 58 Comfort Valve wiring diamgram. FP1038 Troubleshooting comfort valve 1. Locate LED light on valve. wiring diagram 2. LED will blink after every valid command 3/24/00 djt received by the transmitter; this is not an error. 3. Failure codes may occur anytime after pilot burner is lit. 4. Sequence is failure code followed by light not blinking for 30 seconds. 5. In the event of multiple failure codes, next failure code follows previous failure code by approximately 3 seconds. If an Error Code 3 is observed while performing the testing, complete the following: 1. Make sure the spade connectors are pushed all the way on. If the Error Code 3 is still showing, then go to the next step. 2. Switch the front two thermopile leads with the back two. Be sure the white lead is connected to the spade with the white dot next to it. If the Error Code 3 is still showing, replace the thermopiles. If an Error Code 8 is observed while performing the testing, complete the following: 1. Confirm the valve is not in REMOTE mode. • If the valve is producing Error Code 8 and in REMOTE mode, the valve is defective and should be replaced. • If the valve is in LOCAL mode and producing Error Code 8, then go to the next step. 2. Slide the Remote/Local switch to REMOTE and teach the valve a transmitter (refer to Item 6, page 29). The Error Code will clear itself after approximately 1¹⁄₂ minutes and return to normal operation. 33 DV360/580 Series Direct Vent Gas Fireplace LED Count 8 7 Service Action Replace valve Confirm stepper motor connection exists 5 Confirm fan connection exists and works 4 Confirm gas type; jumper in place 3 Replace thermopiles 2 Turn fan ON NOTE: Some keys are not active. Auto Path If the manual switch is set to REMOTE, press the mode button to display AUTO on the transmitter. Does the transmitter display the room and temperature setting? Move switch from LOCAL to REMOTE. Press any key within 30 seconds. Yes If the setting is above room temperature on the transmitter, does the main valve and fan turn on? No Yes If the setting is below room temperature on the transmitter, does the main valve and fan turn off? No Turn pilotstat knob to OFF to turn valve completely off 34 20010667 DV360/580 Series Direct Vent Gas Fireplace Comfort Valve System Control Sequence of Operation with Transmitter Set manual switch to local or remote Five minute wait period Light pilot burner Did the LED stop blinking? Yes Review LED failure analysis Release pilotstat knob Yes Turn pilotstat knob from PILOT to ON Move switch from local to remote. Press any key on transmitter. Move switch back to local Yes Transmitter controls fan Yes Turn pilotstat knob to PILOT to turn off main burner No Choose Local or Remote path. Set switch to manual or remote On Path Local Path If manual switch is set to LOCAL, did main burner light? Cycle switch once and leave in remote. Press any key on transmitter for recognition operation If the manual switch is set to REMOTE, press the mode button to display “ON”. Does transmitter control the main burner and fan? Move switch from manual to remote. Press any key on transmitter. Yes Does transmitter change levels of flame height, fan speed and set temperature? No Yes Turn pilotstat knob to OFF to turn valve completely off Set levels of flame height and fan to “0” to shut off main burner and fan Turn pilotstat knob to OFF to turn valve completely off 20010667 35 DV360/580 Series Direct Vent Gas Fireplace Troubleshooting - Honeywell VS8421 Remove Window Frame Assembly Before Service Work START CHECK NO • Supply Line Hooked Up • Shutoff Valve Open ▼ Gas Supply On YES • Lockout Has Engaged. Wait 60 ▼ • NO ▼ Pilot Lights With Piezo Ignitor • • • For Air In The Lines • Thermopile Needs A Min. YES ▼ NO • • • ▼ Pilot Stays Lit Seconds And Try Again. For Spark At Electrode While Depressing Piezo 1/8" Gap To Pilot Hood Needed. All Wiring Connections Replace Piezo Ignitor 325mv. Adjust Pilot Flame Height. All Wiring Connections Replace Thermopile Thermocouple Needs A Min. Of 14mv YES • Valve Is Turned On • Wall Switch Is Not Turned On. Pilot Lights Main Burner YES ▼ NO ▼ ▼ • • • Watch For Grounded Wires! Thermopile Needs A Min. 325mv. Plugged Burner Orifice Defective Valve. Turn To Pilot, Meter Should Read Greater Than 100mv. If Not, Replace. SYSTEM OK 36 20010667 DV360/580 Series Direct Vent Gas Fireplace Troubleshooting the Gas Control System SIT NOVA 820 Millivolt Valve NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. WARNING: Before doing any gas control service work, remove glass front. SYMPTOM 1. Spark ignitor will not light 2. Pilot will not stay lit after carefully following lighting instructions. 3. Pilot burning, no gas to main burner 4. Frequent pilot outage problem. 20010667 POSSIBLE CAUSES A. Defective or misaligned electrode at pilot. CORRECTIVE ACTION Using a match, light pilot. If pilot lights, turn off pilot and push the red button again. If pilot will not light - check gap at electrode and pilotshould be 1/8” to have a strong spark. B. Defective ignitor Push Piezo Ignitor Button. Check for spark at (Push button) electrode and pilot. If no spark to pilot, and electrode wire is properly connected, replace ignitor. A. Defective pilot generator Check pilot flame. Must impinge on thermo(thermocouple), remote wall couple/thermopile. Note: this pilot burner switch assembly utilizes both-a thermocouple and a thermopile. The thermocouple operates the main valve operation (On and Off). Clean and or adjust pilot for maximum flame impingement on thermopile and thermocouple. B. Defective automatic valve Turn valve knob to “Pilot”. Maintain flow to pilot; milivolt meter should read greater than 10 mV. If the reading is okay and the pilot does not stay on, replace the gas valve. Note: An interrupter block (not supplied) must be used to conduct this test. A. Wall switch or wires Check wall switch and wires for proper connections defective Jumper wire accross terminals at wall switch, if burner comes on, replace defective wall switch. If okay, jumper wires across wall switch wires at valve, if burner comes on, wires are faulty or connections are bad. B. Thermopile may not be 1. Be sure wire connections from thermopile at gas generating sufficient valve terminals are tight and thermopile is fully millivoltage inserted into pilot bracket. 2. One of the wall switch wires may be grounded. Remove wall switch wires from valve terminals if pilot now stays lit, trace wall switch wiring for ground. May be grounded to fireplace or gas supply. 3. Check thermopile with millivolt meter. Take reading at thermopile terminals of gas valve. Should read 250-300 millivolts (minimum 150) while holding valve knob depressed in pilot position and wall switch “Off”. Replace faulty thermopile if reading is below specified minimum. C. Plugged burner orifice. Check burner orifices for debris and remove. D. Defective automatic valve Turn valve knob to “On”, place wall switch to “On” operator. millivolt meter should read greater than 100 mV. If the reading is okay and the burner does not come on, replace the gas valve. A. Pilot flame may be too low Clean and/or adjust pilot flame for maximum flame or blowing (high) causing the impingement on thermopile and thermocouple. pilot safety to drop out. B. Possible blockage of the Check the vent terminal for blockage (recycling the vent terminal. flue gases) 37 DV360/580 Series Direct Vent Gas Fireplace Troubleshooting the Gas Control System START •TURN GAS SUPPLY OFF NO • TURN ON/OFF SWITCH TO CALL FOR HEAT "ON" POWER TO MODULE (24V NORMAL) YES SPARK ACROSS IGNITOR SENSOR GAP NO CHECK: • LINE VOLTAGE (120VAC) • LOW VOLTAGE TRANSFORMER (19.5 minimum VAC) • ON/OFF SWITCH • WIRING CONNECTIONS UNPLUG IGNITION LEAD AND CHECK SPARK AT MODULE (24VAC normal) NO • REPLACE MODULE SPARK OK? YES YES • CHECK IGNITION CABLE GROUND WIRING, CERAMIC INSULATOR AND GAP. CORRECT AS NECESSARY • CHECK BOOT OF IGNITION CABLE FOR SIGNS OF MELTING OR BUCKLING. TAKE PROTECTIVE ACTION TO SHIELD CABLE AND BOOT FROM EXCESSIVE TEMPERATURES. • TURN GAS ON NO PILOT BURNER LIGHTS? YES SPARK STOPS WHEN PILOT IS LIT? NO NO YES SYSTEM RUNS UNTIL ON/OFF SWITCH IS IN "OFF" POSITION YES TROUBLESHOOTING ENDS 38 NOTE: IF S8600B GOES INTO LOCKOUT, RESET SYSTEM. • CHECK CONTINUITY OF IGNITION CABLE AND GROUND WIRE. • CLEAN FLAME ROD • CHECK ELECTRICAL CONNECTIONS BETWEEN FLAME ROD & MODULE. • CHECK FOR CRACKED CERAMIC FLAME ROD INSULATOR. • CHECK THAT PILOT FLAME COVERS FLAME ROD AND IS STEADY BLUE • ADJUST PILOT FLAME. • IF PROBLEM PERSISTS, REPLACE MODULE. YES MAIN BURNER LIGHTS? • CHECK THAT ALL MANUAL GAS VALVES ARE OPEN, SUPPLY TUBING AND PRESSURES ARE GOOD, AND PILOT BURNER ORIFICE IS NOT BLOCKED. • CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND PILOT OPERATOR ON GAS CONTROL. • CHECK FOR 24VAC ACROSS PV-MVPV TERMINALS ON MODULE IF VOLTAGE IS OKAY, REPLACE GAS CONTROL IF NOT, REPLACE MODULE. NO • CHECK FOR 24VAC ACROSS MV-MVPV TERMINALS IF NO VOLTAGE, REPLACE MODULE. • CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND GAS CONTROL. IF OKAY, REPLACE GAS CONTROL, OR GAS CONTROL OPERATOR. NOTE: IF S8600B GOES INTO LOCKOUT, RESET SYSTEM • CHECK FOR CONTINUITY OF IGNITION CABLE AND GROUND WIRE. NOTE: IF GROUND IS POOR OR ERRATIC, SHUTDOWN MAY OCCUR OCCASIONALLY EVEN THOUGH OPERATION IS NORMAL AT THE TIME OF CHECKOUT. • CHECK THAT THE PILOT FLAME COVERS FLAME ROD AND IS STEADY AND BLUE. • IF CHECKS ARE OKAY, REPLACE MODULE. 20010667 DV360/580 Series Direct Vent Gas Fireplace Troubleshooting the Gas Control System SIT 822 Valve with Synetek Electronic Control Operating Diagram Abnormal Operation Normal Operation 5 sec Inter-Trial Delay ON/OFF Switch Closed? YES Safe Start Check On? NO YES 0 Sec Purge Ignition Trial: 30 sec Spark ON Pilot Valve ON. Has Flame been Detected within 30 sec? LED: 5 Flashes? Reverse power cord polarity NO ON/OFF Switch Opened? LED: 2 Flashes? Reset by interrupting ON/OFF switch for power for 10 sec YES Pilot, Valve OFF, Spark OFF NO Have three ignition trials been completed? Spark Off. Main Valve ON. Pilot Flame Continuously Monitored Pilot Flame Sense OK? LED: Steady Flash? Lockout: Flame detected out of sequence Reset by interrupting ON/OFF switch or power for 10 sec NO LED: 3 Flashes? Lockout: Flame Loss Reset by interrupting ON/OFF switch or power for 10 sec YES Main Valve OFF, Spark ON Has flame been detected within 30 sec? YES Pilot and Main Valve OFF? NO Have three pilot flame losses been detected? YES YES 0 sec Post Purge? Heating Cycle Complete LED: OFF 20010667 39 DV360/580 Series Direct Vent Gas Fireplace Conversions must be completed by qualified personnel 2. Insure the rubber gasket (D) is properly positioned Fuel Conversion Instructions CAUTION: Logs may be HOT! Allow to cool before proceeding. and install the new HI/LO pressure regulator assembly to the valve using the new screws (E) supplied with the kit. Tighten the screws securely. (Ref. torque = 25 in/lb) (Fig. 65) 3. Install the enclosed conversion label (F) to the valve body where it can easily be seen. (Fig. 65) Valve conversion is complete. 1. Open louvre assembly bottom to gain access to valve. Remove window frame assembly. (See “Window Frame Assembly Removal”, Page 24, Fig. 47) 2. Remove logs if previously installed. Honeywell Valve 1. Remove cap from HI/LO knob. This can be accomplished by lifting the plastic cap off the screw. (Fig. 63) 2. Remove the screw from center of HI/LO knob with small screwdriver turning counterclockwise. (Fig. 63) 3. Insert conversion screw supplied in conversion kit. Blue for natural gas, red for LP. 4. Tighten screw, replace cap. E N IL FP OF OT To convert the DV360/580 units for use with a different gas follow these instructions. Before proceeding, turn control knob on valve to “OFF” and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance. O D F Cap HI Lift Open LO Hi/Lo Knob FC108 HI Fig. 65 Replace regulator. Burner Orifice Conversion FC108 DV360 SIT LO Remove Center Screw CO100 Fig. 63 Remove center screw from Hi/Lo knob. CO100 Gas conversion HI-LO knob 3/15/99 djt NOVA SIT820 Valve 1. Using the TORX T20 bit, remove and discard the three (3) pressure regulator mounting screws (A), pressure regulator tower (B) and the spring and diaphragm assembly (C). (Fig. 64) A regulator 1. Remove the screws that secure the fettle and the burner tube assembly, located behind the burner conversion tube assembly. Remove 10/03 the four (4) screws that secure the burner housing assembly to the base pan at the right and left end of the burner housing assembly. (Fig. 66) Pilot Location Burner Housing Assembly Remove Screws B C PIL OT N OFF O CO129 Burner Tube Assembly Remove Screws Fig. 66 Remove screws holding burner housing assembly and burner tube assembly. FC107 Fig. 64 Remove mounting screws, pressure regulator tower and spring and diaphragm assembly. 40 FC107 SIT820 valve conversion 10/03 2. Remove the fettle and the burner tube assembly. ����� Slide the burner housing assembly to the right and ������������ up to free the orifice. ��������� 20010667 DV360/580 Series Direct Vent Gas Fireplace 3. Using a 1/2” open end wrench remove the orifices. (Fig. 67) Gasket Burner Housing Mixing Tube Front Burner Orifice (Refer to Table on Page 42) Natural Rear Burner Orifice (Refer to Table on Page 42) CO130 Propane Fig. 67 Burner orifice replacement. 4. Converting LP to NG, remove bracket/gasket assembly by unfastening the screw which secures the bracket to the burner����� tray base. Discard bracket and refasten the screw into the hole. (Fig. 67a) �������������� Converting NG to LP, assemble the bracket/gas��������� ket assembly to the burner tray assembly base by unfastening the screw on the tray to the right side of the orifice. Slide the bracket/gasket assembly over the fitting on the manifold toward the back with the gasket to the right. Secure the bracket/gasket assembly using the screw removed earlier. (Fig. 67a) CO131 Fig. 68 Replace mixing tube and gasket. 8. Reassemble the burner housing assembly, the burner tube assembly and the fettle in reverse order. ����� ����������� ��������� DV580 1. Remove manifold mounting screw from burner. (Fig. 69) 2. Remove burner orifice from manifold assembly using 3/8” wrench. (Fig. 70) 3. Install conversion orifices in place of orifices just removed. Manifold Assembly Pilot Location Burner Pan LP Bracket/Gasket Assembly - in place for use with LP Gas; remove for use with Natural Gas Manifold Mounting Screw Screw Orifice CO132 Fig. 67a LP bracket/gasket assembly. 5. Replace the orifices according to the table on Page 42. ����� 6. Replace the mixing tube on the burner housing by ���������� removing the two (2) screws that secure the mixing ���� tube to the burner housing assembly. Remove the old gasket behind the mixing tube. (Fig. 68) NOTE: The mixing tube for propane gas has only two bimetallic springs that are in the closed position at cold start. The mixing tube for natural gas has two spring/shutter collar assemblies that are in the closed position at cold start. Make sure the correct mixing tube is used for conversion. 7. Use the new gasket supplied in the conversion kit and proper mixing tube and replace in reverse order. 20010667 Log Support (DV580) CO101a CO101a Fig. 69 Remove manifold assembly. DV360/580 Gas Conversion Manifold Rear Burner Orifice: 1/28/00 (Refer to Conversion Kit Orifice added manifold screw 4/7/00 djt Chart) Front Burner Orifice: (Refer to Conversion Kit Orifice Chart) CO102a Fig. 70 Burner orifice replacement. 4. Remove air shutters from burner pan by removing shutter retaining CO102a screw then air shutter. (Fig. 71) 5. Replace only theDV360/580 rear air shutters. Natural Gas: Rear air shutter, fully open. Gas Conversion Front air shutter, fully open. 1/28/00 djt LP: Rear air shutter, fully open. Front air shutter, fully open. 41 DV360/580 Series Direct Vent Gas Fireplace 2/15/99 djt Pilot Orifice Conversion NOTE: It is not necessary to remove the pilot tube for conversion. 1. Remove pilot hood by lifting up. (Fig. 72) 2. Remove pilot orifice with Allen wrench. (Fig. 73) 3. Install conversion pilot orifice. 4. Re-install pilot hood and be sure to align with index tab. Installation is complete. Motor Top Cap Piezo Ignitor PIL Pilot Hood OFF • LED Local/ Remote Switch Pilot Bracket Pilotstat Knob Plug Antenna FP1037 Fig. 74 Comfort control valve. CO105a Center Plunger Fig. 72 Remove pilot hood. FP1037 Honeywell comfort valve 3/22/00 djt Motor Top Cap OT PIL Red - LP D REMOTE Blue - NG LOCAL CO105a DV360/580 Gas Conversion Pilot 1/28/00 djt Snap Ring OFF • O • N Allen Wrench LE Index Tab FP1037b Fig. 75 Depress and turn center plunger. CO106a Fig. 73 Remove pilot orifice. Fuel Conversion Instructions Honeywell Comfort CO106aControl Valve ONLY WARNING:DV360/580 The conversion must only be Gas undertaken by Conversion a qualified, certified gas apPilot2 pliance installer. 1/28/00 djt Installation Precautions Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance. CAUTION: Logs may be hot! Conversion Procedure 1. Open bottom grille to gain access to valve. Remove glass door. (Refer to “Window Frame Assembly Re42 OT D Gas Conversion 6. Re-install manifold Air shutter to burner pan. LE CO103 CO103 Fig. 71 Remove air shutter from burner pan. O • N Front View REMOTE Air Shutter moval Section” Page 24, Fig. 47) 2. Remove logs if previously installed. CAUTION: Logs may be hot! 3. Remove and replace plug on lower right hand side of the valve; Red for LP and blue for NG. (Fig. 74) 4. Remove motor top cap. Depress and turn center plunger until arrow points to correct screw. Red for LP and Blue for NG. NOTE: Plunger will “snap” into NG position when arrow is close to blue screw. It will not “snap” at LP (Red) position. (Fig. 75) LOCAL Burner Pan Shutter Retaining Screw Burner Orifice Conversion DV360 1. Remove the screws that secure the fettle and the burner tube assembly, located behind the burner FP1037b tube assembly. Remove the two (2) screws comfort valve that secure the burner housing assembly to the base pan convert 3/6/01assembly. djt (Fig. at the right end of the burner housing 66) 2. Remove the fettle and the burner tube assembly. Slide the burner housing assembly to the right and up to free the orifice. 3. Using a 1/2” open end wrench remove the orifices. (Fig. 67) 4. Converting LP to NG, remove bracket/gasket assembly by unfastening the screw which secures the bracket to the burner tray base. Discard bracket and refasten the screw into the hole. (Fig. 67a) Converting NG to LP, assemble the bracket/gasket assembly to the burner tray assembly base by 20010667 DV360/580 Series Direct Vent Gas Fireplace 5. 6. 7. 8. unfastening the screw on the tray to the right side of the orifice. Slide the bracket/gasket assembly over the fitting on the manifold toward the back with the gasket to the right. Secure the bracket/gasket assembly using the screw removed earlier. (Fig. 67a) Replace the orifices according to the table on Page 42. Replace the mixing tube on the burner housing by removing the two (2) screws that secure the mixing tube to the burner housing assembly. Remove the old gasket behind the mixing tube. (Fig. 68) NOTE: The mixing tube for propane gas has only two bimetallic springs that are in the closed position at cold start. The mixing tube for natural gas has two spring/shutter collar assemblies that are in the closed position at cold start. Make sure the correct mixing tube is used for conversion. Use the new gasket supplied in the conversion kit and proper mixing tube and replace in reverse order. Reassemble the burner housing assembly, the burner tube assembly and the fettle in reverse order. 2. Remove pilot orifice with needlenose pliers. (Fig. 77) 3. Install conversion pilot orifice. 4. Reinstall pilot hood. Be sure to align pilot hood with index marks. Pilot Hood Index Marks Pilot Bracket CO105 Fig. 76 Remove pilot hood. CO105 Gas Conversion Pilot 2/15/99 djt DV580 1. Remove manifold mounting screw from burner. (Fig. 69) 2. Remove burner orifice from manifold assembly using 3/8” wrench. (Fig. 70) 3. Install conversion orifices in place of orifices just removed. 4. Remove air shutters from burner pan by removing shutter retaining screw then air shutter. (Fig. 71) 5. Replace only the rear air shutters. Natural Gas: Rear air shutter, fully open. Front air shutter, fully open. LP: Rear air shutter, fully open. Front air shutter, fully open. 6. Re-install manifold to burner pan. Pilot Orifice Conversion NOTE: It is not necessary to remove the pilot tube for conversion. 1. Loosen pilot hood turning counterclockwise using a 7/16” wrench. (Fig. 76) Pilot Orifice CO106 Fig. 77 Remove pilot orifice. 5. Turn the gas supply valve and gas valve on and test for leaks. Use a 50/50CO106 solution of liquid soap and Conversion water to test for leaks Gas at gas fittings and joints. Apply Pilot2 water/soap solution with brush only - do not over ap2/15/99 djt ply. NEVER test with an open flame. 6. Follow procedure on rating plate to light the pilot. Check for leaks. 7. Turn main burner on and check for leaks. 8. Install logs. Refer to Page 25 for proper log placement. Installation complete. Table 1 Injector Orifice Size Matrix Kit # 20010751 Model DV360RP/RFP Kit # 20010752 20011025 Model DV360RN/RFN DV360EN 20010667 Conversion to Natural Gas Burner Orifice Front Part # Rear Part # #53 20007347 #43 30000512 (.0595”) (.089”) Conversion to LP Burner Orifice Front Part # Rear Part # #64 20010935 #54 20000130 (.036”) (.055”) Input (BTU/hr) Minimum Maximum 18,500 30,000 Input (BTU/hr) Minimum Maximum 17,000 30,000 43 DV360/580 Series Direct Vent Gas Fireplace Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs as per the instructions in this manual. Always handle the logs with care as they are fragile and may also be hot if the fireplace has been in use. FK24/FK12 Fan Assembly The fan unit requires periodic cleaning. At least once per month in the operating season, open the lower louvre panels and wipe or vacuum the area around the fan to remove any build up of dust or lint. Brass Trim Clean the brass trim pieces using a soft cloth lightly dampened with lemon oil. Do not use water or household cleaners on any brass components. To obtain proper operation, it is imperative that the pilot and burner’s flame characteristics are steady, not lifting or floating. Typically, the top 3/8” or 1/2” of the thermopile should be engulfed in the pilot flame. (Fig. 78) To adjust pilot burner; (by qualified service technician) 1. Remove pilot adjustment cap. 2. Adjust pilot screw to provide properly sized flame. 3. Replace pilot adjustment cap. The primary air shutter is set at factory and should only be adjusted, if necessary, by a qualified service technician. Contact your local representative to arrange an annual service program. Cleaning the Standing Pilot Control System The burner and control system consists of • burner tube • gas orifice • pilot assembly • thermopile • millivolt gas valve Most of these components may require only an occasional checkup and cleaning and some may require adjustment. If repair is necessary, it should be performed by a qualified technician. PSE Pilot 3/8” - 1/2” (10 - 13 mm) F584-703 SIT Pilot Fig. 78 Correct pilot flame appearance. F584-703 Honeywell & PSE pilot flames Logs May Be HOT!! 1. Turn off pilot light at gas valve side. 2. Let fireplace cool if it has been running. 3. Remove window frame assembly. (Refer to Window Frame Assembly Removal section) 4. Remove logs. 5. Vacuum burner compartment especially around orifice primary air openings. 6. Visually inspect pilot. Brush or blow away any dust or lint accumulation. 7. Reinstall logs. 8. Ignite pilot - Refer to Lighting Instructions. 9. Reinstall window frame assembly. 44 20010667 DV360/580 Series Direct Vent Gas Fireplace 1. DV360 1c 1 DV580 1c 5 3a 1a 1e 1h 4 1i 1b 3a,b 1j 1g 1b 1a 7a 1e 1d 1h 7b 6 20 12 10 18 15 6 12a 2 1f 8 13 9a 21 11 9b 23 17 16 33 32 26a,b 22a-d 27 19 a/b 34 35a/b 36 28 T OFF O O H PILOT ADJ ON L I 24 a/b PIL 14 25 a/b 39 41 40 48 46 37 30 29 38 31 42 47 52 51 49 53 50 54 61 56 55 58 62 OT PILOFF • D 60a,b LE LOCAL REMOTE •ON 57a,b 59a,b 64 63 68 66 65a,b 66 67 70a 72a,b 78 71a,b 69 79 77 70b LO HI 10667 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, DV360/580 without notice. DV360/580 20010667 parts 2/06 djt 45 DV360/580 Series Direct Vent Gas Fireplace DV360/580 (continued) Ref. 1. 1a. 1b. 1c. 1d. 1e. 1f. 1g. 1h. 1i. 1j. 2. 3a. 3b. 4. 5. 6. 7a. 7b. 8. 9a. 9b. 10. 11. 12. 12a. 13. 14. 15. 16. 17. 18. 19a. 19b. 20. 21. 22a. 22b. 22c. 22d. 23. 24a. 24b. 25a. 25b. 26a. 26b. 46 Description Log Set Log Front Left Log Front right Log Rear Log Top Left Log Top Right Log Top Center Left Log Top Center Log Overlay Volcanic Rock Ember (Package) Lava Rock (Burner) Burner Housing Assy - Nat. Burner Housing Assy - LP Burner Tube Assy. Ceramic tile (single) Manifold Assembly (* Refer to Note on Page 45) Ceramic Hearth Panel (Left) Ceramic Hearth Panel (Right) Ceramic Panel (Rear) Ceramic Panel (Left Side) Ceramic Panel(Right Side) Glass with Gasket Gasket Glass Door Frame Assy Door Assy Clamp Frame Window Trim Frame Window (Pb) (w/two magnets) Louvre Assembly Top Louvre Assembly Bottom Bottom Louvre Hinge Deflector Top LP Valve Conversion - Red Natural Valve Conversion - Blue Grate Assembly Fettle Orifice - Front Burner - LP Orifice - Front Burner - Nat. Orifice - Rear Burner-LP Orifice - Rear Burner-Nat Switch On/Off Valve - Honeywell VS8421 - Nat. Valve - Honeywell VS8421 - LP Valve - SiT 820 - Nat. Valve - SIT 820 - LP Pilot Assembly - Nat. Pilot Assembly - LP DV360 20010671 20010673 20010672 20010675 -20010676 -20010677 20010674 20000376 51915 -20011467 20011322 20010580 57803 20010601* --------20002622 54174 57483 10000039 10000040 52356 54364 20000550 20000572 -20010490 20010935 20007347 20000130 30000512 51842 --20010563 20010645 10002264 10002265 DV580 10007545 10007540 (E9) 10007541 (E10) 10007539 (E8) 10007543 (E12) 10007544 (E13) 10007542 (E11) --20000376 51915 57897 10007533 --10002165 10002492 10007992 10007993 10007994 10007995 10007996 20002369 10000992 10007538 -54174 20002072 20002380 20002381 52356 20002287 20000550 20000572 10007537 -20002540 20002150 20002958 20002498 51842 10001782 10001759 52677 52678 10002264 10002265 20010667 DV360/580 Series Direct Vent Gas Fireplace DV360/580 (continued) Ref. 27. 28. 29. 30. 31. 32. 33. 34. 35a. 35b. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. 57a. 57b. 58. 59a. 59b. 60a. 60b. 61. 62. 63. 64. 65a. 65b. 66. 67. 68. Description Electrode Ignitor w/Cable Nut Electrode Pilot tube 1/8” x 24” long w/fittings (SIT Pilot) Thermocouple - RN/RP Cable Ignitor - RN/RP Thermopile - RN/RP Pilot Top Convertible Hood Pilot 3 way Pilot Orifice #65 (Nat.) Pilot Orifice #35 (LP) Ignitor Piezo Air Shutter (Nat.) Fan w/ Bracket (FK24) Electrical Cord (6ft.) Fan Temp. Sensor Speed Control Speed Control Knob Remote Switch Kit (Not Shown) Piezo Ignitor Replacement Kit (Not Shown) Ceramic Refractory Lining Kit (Optional) (Not Shown) Shield Heat Pilot Plate Relief w/Gasket Assembly Burner Tray Firestop Zero Clearance Sleeve Plate Cover Air Inlet Ass’y Gasket Plate Air Inlet Flue Cover Plate Flue Cover Gasket Flue Pipe Ass’y Gasket Plate Cover Flue Pipe Antennae HW 395783-1 RFN/RFP Valve RF Valve 8310E - Natural RF Valve 8310E - LP Thermopile - RF Valves Pilot Orifice - Natural - RF Pilot Orifice - LP - RF Pilot Assembly - Natural (3 Way) RF Pilot Assembly - LP (3 Way) RF Transmitter Cord Set Pilot Tube 1/8” x 24” long w/Fittings (PSE Pilot) Refractory Bay39 Set Regulator Head (Nat.) Regulator Head (LP) Bracket Rear Log Gasket Assy. Burner Base Plate Relief w/Gasket Assy. 20010667 DV360 10001297 57886 10001296 53373 53194 51827 10002266 10002385 10002268 10002269 20000062 -54103 51865 51704 51738 51882 53875 20000062 Refer to Page 47 --52523 54623 10002766 10002449 10002298 10002233 10004933 10002237 20003561 20003719 20003720 20002400 20000908 20000907 20002266 20002268 20002047 20002541 10003279 10000506 10001006 10001007 20010622 10006154 10002429 DV580 10001297 57886 10001296 53373 53194 51827 10002266 10002385 10002268 10002269 20000062 10007355 54103 51865 51704 51738 51882 53875 20000062 GACA4P0 10007518 10004192 52523 54623 20002461 10002449 10002298 20002391 20002481 10002237 20003561 20003719 20003720 20002400 20000908 20000907 20002266 20002268 20002047 20002541 10003279 n/a 10001006 10001007 10007535 10007528 10002862 47 DV360/580 Series Direct Vent Gas Fireplace DV360/580 (continued) Ref. 69. 70a. 70b. 71a. 71b. 72a. 72b. 73. 74. 75. 76. 77. 78. 79. Description Transformer EN/EP Ignitor Module Honeywell EN/EP Ignition Control Synetek (EN) Valve - SIT 822 - EN Valve - SIT 822 - EP Pilot Assembly SIT Top Conv. - EN Pilot Assembly SIT Top Conv. - EP Sensing Electrode w/Cable EN/EP (not shown) Wire Harness, Honeywell EN/EP (not shown) Tubing 3/8” OD Aluminum Nut 3/8” ID Brass, Compression Wire Harness (EN) Synetek (low voltage) Wire Harness (EN) Synetek Electrical Cord (6ft) Ignition Control DV360 7522409 20000005 10007939 --10002387 10002388 57885 57899 20010564 7523136 10008139 10008140 10008298 DV580 7522409 20000005 -57884 57883 10002387 10002388 57885 57899 ------ *NOTE: For DV360, when ordering Manifold Assembly, also order #75 (qty 1) and #76 (qty 2). Fuel Conversion Kits Natural Gas to LP DV360RN/EN/RFN DV580RN/EN DV580RFN LP to Natural Gas DV360RP/EN/RFP DV580RP/EP DV580RFP 48 Kit # 20010752 Kit # 10007997 Kit # 10008274 Kit # 20010751 Kit # 10007998 Kit # 10008275 20010667 DV360/580 Series Direct Vent Gas Fireplace Optional Accessories Fan Kits FK12 Fan Assembly 1. Open louvre assembly bottom. 2. Install FK12 fan in back of unit between hearth supports. (Fig. 79) 3. Secure fan on velcro strips. 4. Power to the fan can be supplied by plugging the supply lead into a conveniently located wall socket or by using a hard-wired EB-1 connector box. 5. Be sure fan motor does not touch hearth supports. Cold Air Box Front of Unit Hard (Direct) Wire Hook Up Hearth Pan Base Pan FK12 Fan FP1004 Fig. 79 FK12 Fan Kit placement. First connect ground wire to ground stud located on the base of either box. Black wire from supply should connect to the variable speed switch. Alternate speed switch wire connects to temperature sensor. Alternate lead from sensor connects to fan. Alternate fan lead connects back to the white supply wire. (Fig. 81) Any electrical rewiring of this fan must be completed by a qualified electrician. FK24 Fan Assembly Fan specifications: 120 volt, 60 Hz, .75 Amp. FP1004 This fan does not need regular maintenance, however Fan placement periodic cleaning is required. Check the area under the DV360/580 Series control door and in front of the fan and wipe or vacuum 1/25/00 djt operating season. at least once a month during the Should this fan require servicing, the power supply must be disconnected. Turn off all power before hook up. Electrical Box Heat Sensor Fan The FK24 comes with the electrical cord attached. A E Side View Method A Route the 6’ (1.8m) lead fitted to the unit to a conveniently located wall socket. Method B If the EB-1 receptacle box (Pt. #ZA1200) was correctly connected when the unit was installed, the fan lead can be directly plugged into the EB-1 plug socket. 5. Whether wiring directly to the fan junction box (Option A) or into the EB1 (electrical box, Option B) first ensure cable is secured using box connector. The fireplace, when installed must be electrically connected and grounded in accordance with local codes, with the current CSA C22.1 Canadian Electrical Code or for US installations, follow local codes and the National Electrical Code, ANSI/NFPA No. 70. TP LO PILO OFF O TO FF HI N O PIL T 20010667 OFF TH 1. Slide fan assembly from the left side into the fireplace opening, line up mounting holes with screw studs on back of fireplace and fasten with #10 - 24 hex nuts. (Fig. 80) 2. Install thermal sensor on bottom of firebox using #10 - 24 hex nuts. 3. (Option A) - Place electronic fan speed control box on bottom of fireplace base, lining up mounting holes with screw studs. Fasten fan speed control box with #10 - 24 hex nuts. (Option B) - The speed control can be installed in an electrical box at normal wall switch height for convenient access. 4. The power supply may be connected in 2 ways: Fan Speed Switch FP1026 Gas Line Valve Fig. 80 FK24 fan placement. Temperature Sensor Speed Control Black White Ground Fan FP1026 FK24 fan placement 1/27/00 djt FP1025 Fig. 81 FK24 fan wiring. FP394 WIRING DIAGRAM 11/20/96 49 DV360/580 Series Direct Vent Gas Fireplace Remote Controls Optional remote control units are available to control different functions of the appliance. Model RC1 RC2 IMTFK Functions Controlled ON/OFF ON/OFF and Temperature Wall mounted thermostat control Rear Ceramic Panel Back of Firebox Burner Ceramic Refractory Panels Rear Log Support Ceramic refractory panels are available to line the firebox area. Unit DV360 DV360 DV360 DV360 DV580 Kit Model DV360CRSS DV360CRR DV360CRB DV360CRG DV580CR H102 Sandstone Red Black Grey Take care when handling the refractory panels as they are fragile until held in place and supported. Fig. 83 Rear ceramic panel placement. Decorative Bay Windows H102 The bay window is available for the DV360 only. rearkitceramic support Installation 2/23/99 djt Remove the existing louvre assembly top. Assemble the Bay Window Kit according to the instructions supplied with the kit. (Fig. 84) Installation Instructions Upper Grille Assembly 1. Remove window frame assembly and logs. 2. Remove three (3) screws securing heat shield to combustion dome. (Fig. 82) 3. Place rear ceramic panel in back of unit. (Fig. 83) 4. Place side panels. 5. Replace heat shield, logs and window frame assembly. Ceramic Refractory Ceramic Refractory Section A Heat Shield Heat Shield Window Assembly Base Grille Assembly FP1194 Fig. 84 Bay window. (3) Screws H103 Fig. 82 Heat shield. H103 heat shield 3/1/99 djt 50 DecorativeFP1194 Frame Trims Install bay Side View Section A window trim kits are available for A selection of decorative frame 2/19/02 djt mounting around the outside of the appliance to enhance its visual effect on the room. Installation instructions for each decorative frame trim are included with the frame trim kit. Contact your authorized distributor for details of the trim kits and ordering information for the trim kits applicable to this model appliance. 20010667 DV360/580 Series Direct Vent Gas Fireplace Arch/Square Face Kit for the DV360 Romanesque - Arch 41DVARFKB 41DVARFKR 41DVARFKS Romanesque - Square 41DVSRFKB 41DVSRFKR 41DVSRFKS Marquette - Arch 41DVAMTKB 41DVAMTKR 41DVAMTKS Marquette - Square 41DVSMTKB 41DVSMTKR 41DVSMTKS 20010667 Black Rustic Bronze Pewter Black Rustic Bronze Pewter Black Rustic Bronze Pewter Black Rustic Bronze Pewter 51 DV360/580 Series Direct Vent Gas Fireplace For Use in Mobile Homes: Model DV360RMH This appliance may be installed as an OEM installation in a manufactured home (US only), or a mobile home; it must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard Title 24 CFR Part 3280, or Standard for Installation in Mobile Homes CAN/ CSA Z240 MH. This appliance is only for use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the appliance. This gas fireplace should be installed by a qualified installer in accordance with local building codes, and with current CSA-B149.1 Installation codes for Gas Burning Fireplaces and Equipment, and CAN/ CSA Z 240.4 Canada. A manufactured home (US only) or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR Part 3280, or when such a standard is not applicable, the Standard for Manufactured Home Installations ANSI/NCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing CSA Z240.4. The appliance when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the current National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING: 1. This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies. 2. Children and adults should be alerted to the hazards of fireplace high surface temperatures and should stay away to avoid burns or ignition of clothing. 3. Children should be carefully supervised when in the same room as your fireplace. 4. Under no circumstances should this fireplace be modified. Parts removed for servicing should be replaced prior to operating this fireplace again. 5. Installation and any repairs to fireplace should be performed by qualified installer, service agency or gas supplier. A professional service person should be contacted to inspect fireplace annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc. 6. Control compartments, burners and air passages in this fireplace should be kept clean and free of dust and lint. Make sure that the gas valve and pilot light are turned off before you attempt to clean this fireplace. 52 7. The venting system (chimney) of this fireplace should be checked at least once a year and if needed your venting system should be cleaned. 8. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. This fireplace should not be used as a drying rack for clothing, nor should Christmas stockings or decorations be hung on or around the fireplace. 9. Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this fireplace. 10. The flow of combustion and ventilation air must not be obstructed in any way. 11. When the fireplace is installed directly on carpeting, vinyl tile or any combustible material other than wood, the fireplace must be installed on a metal or wood panel extending the full width and depth of the fireplace. 12. This fireplace requires adequate ventilation and combustion air to operate properly. CFM Corporation Model DV360RMH must be firmly attached to the building. Conversion Instructions 1. Discount power to unit and shut off the gas supply. 2. Remove the window frame assembly (see ‘Window Frame Assembly’ section). 3. Carefully remove the logs. 4. Remove the pilot assembly from bracket. 5. Remove the screws which are holding the burner housing assembly in place. 6. Remove the burner housing assembly. 7. Remove the main and front orifice and replace with the orifice supplied in the conversion kit. Use the small orifice size for the front burner and the bigger orifice size for the main burner. 8. Remove the compression fitting which holds the aluminium tubing in the pilot assembly. This will reveal the pilot orifice which must be replaced with the one provided in the conversion kit. 9a. Units with SIT valve (Refer to illustrations in the installation instructions supplied with the kit): 20010667 DV360/580 Series Direct Vent Gas Fireplace a) Using a Torx T20 or slotted screwdriver, remove and save the three pressure regulator mounting screws (A), pressure regulator tower (B) and diaphragm (C). b) Ensure the rubber gasket (D) is properly positioned and install the new Hi/ Lo pressure regulator to the valve using the new screws (E) supplied with the kit. Tighten screws securely. (Ref. torque: 25 in-lb). c) Install the enclosed identification label (F) to the valve body where it can be easily seen. 9b.Units with Honeywell valve: The Honeywell valve fitted to this unit is preset for LP gas. It is convertible to natural gas by the installation of a color coded “conversion screw.” To insert the conversion screw, refer to the instructions and diagrams in the Honeywell Installation Instructions supplied in the conversion kit packaged with the DV360/DV580RMH unit. 10. Reassemble the fireplace in the reverse order, except for the window frame assembly. Leave this off until the unit has been checked for leaks and the gas supply line has been bled. 11. After bleeding the gas line and checking for leaks with a soap solution, replace the window frame assembly. Fire up the unit, check for flame impingement on the logs, adjusting them if necessary. Check the manifold and supply pressures. NOTE: If further assistance is required, refer to ‘Troubleshooting’ and ‘Parts List’ in this manual. 20010667 53 DV360/580 Series Direct Vent Gas Fireplace 54 20010667 LIMITED LIFETIME WARRANTY DV360/580 Series Direct Vent Gas Fireplace PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations. EXTENDED LIFETIME WARRANTY The heat exchanger, where applicable, and combustion chamber of every Vermont Castings or Majestic gas product is warranted for life against through wall perforation. All appliances equipped with an Insta-Flame Ceramic Burner have limited lifetime coverage on the ceramic burner plaque. Warrantees are made to the original owner subject to proof of purchase and the conditions and limitations listed on this Warranty Document • • • • COMPONENT WARRANTY CAST IRON: All external and internal cast iron parts are warranted for a period of three years. Note: On porcelain enamel finished external parts and accessories The Company offers no Warranty on chipping of enamel surfaces. Inspect all product prior to accepting it for any damage to the enamel. The salt air environment of coastal areas or a high humidity environment can be corrosive to the porcelain enamel finish. These conditions can cause rusting of the cast iron beneath the porcelain enamel finish, which will cause the finish to flake off. Dye lot variations with replacement parts and/or accessories can occur and are not covered by warranty. GLASS DOORS: Glass doors are covered for a period of one year. Glass doors are not warranted for breakage due to misuse or accident. Glass doors are not covered for discoloration or burned in stains due to environmental issues, or improper cleaning and maintenance. BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar mix and masonry cleaners may corrode the brass finish. The Company will not be responsible for, nor will it warrant any brass parts which are damaged by external chemicals or down draft conditions. GAS VALVES: Gas valves are covered for a period of one year • • • • • • ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and mechanical components of the burner assembly are covered for one year. All steel tube burners are warranted for one year. ACCESSORIES: Unless otherwise noted all components and CFM Corporation company supplied accessories are covered for a period of one year. CONDITIONS AND LIMITATIONS • • • • This new Vermont Castings or Majestic product must be installed by a competent, authorized, service contractor. A licensed technician, as prescribed by the local jurisdiction must perform any installation/service work. It must be installed and operated at all times in accordance with the Installation and Operating instructions furnished with the product. Any alteration, willful abuse, accident, or misuse of the product shall nullify this warranty. This warranty is non-transferable, and is made to the original owner, provided that the purchase was made through an authorized supplier of the Company. The customer must pay for any Authorized Dealer in-home travel fees or service charges for in-home repair work. It is the dealers option whether the repair work will be done in the customer’s home or in the dealer’s shop. If upon inspection, the damage is found to be the fault of the manufacturer, repairs will be authorized at no charge to the customer parts and/or labor. 20010667 • Any part and/or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty, whichever is longest. This warranty is limited to the repair of or replacement of part(s) found to be defective in material or workmanship, provided that such part(s) have been subjected to normal conditions of use and service, after said defect is confirmed by the Company’s inspection. The company may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of the defective part(s) Any installation, labor, construction, transportation, or other related costs/expenses arising from defective part(s), repair, replacement, or otherwise of same, will not be covered by this warranty, nor shall the Company assume responsibility for same. Further, the Company will not be responsible for any incidental, indirect, or consequential damages except as provided by law. SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. All other warranties-expressed or implied- with respect to the product, its components and accessories, or any obligations/liabilities on the part of the Company are hereby expressly excluded. The Company neither assumes, nor authorizes any third party to assume on its behalf, any other liabilities with respect to the sale of this Vermont Castings or Majestic product The warranties as outlined within this document do not apply to chimney components or other non CFM Corporation accessories used in conjunction with the installation of this product.. Damage to the unit while in transit is not covered by this warranty but is subject to claim against the common carrier. Contact the dealer from whom you purchased your fireplace/stove (do not operate the appliance as this might negate the ability to process the claim with the carrier). The Company will not be responsible for: a) Down drafts or spillage caused by environmental conditions such as near-by trees, buildings, roof tops, hills, or mountains. b) Inadequate ventilation or negative air pressure caused by mechanical systems such as furnaces, fans, clothes dryers, etc. This warranty is void if: a) The fireplace has been operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals. b) The fireplace has been subjected to prolonged periods of dampness or condensation c) Any damages to the fireplace, combustion chamber, heat exchanger or other components due to water, or weather damage, which is the result of but not limited to, improper chimney/venting installation. d) Any alteration, willful abuse, accident, or misuse of the product has occurred. IF WARRANTY SERVICE IS NEEDED… 1) Contact your supplier. Make sure you have your warranty, your sales receipt, and the model/serial number of your CFM Corporation product. 2) DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF. 55 Efficiency Ratings Model DV360RN DV360RP DV360EN DV360EP DV360RFN DV360RFP DV580RN DV580RP DV580EN DV580EP DV580RFN DV580RFP EnerGuide Ratings Fireplace Efficiency (%) 53 53 53 53 53 53 51.1 51.1 51.1 51.1 51.1 51.1 Steady State (%) Fan-OFF Fan-ON 82 83 83 84 82 83 83 84 82 83 83 84 82 83 83 84 82 83 83 84 82 83 83 84 CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com D.O.E. (AFUE%) 64 64 64 64 64 64 64 64 64 64 64 64
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Author : Provided By MANUALSLIB.COM - http://www.manualslib.com/ Create Date : 2012:05:27 06:10:41Z Keywords : manuals, instruction manuals, user manuals, service manuals, user guides, pdf manuals, owners manuals, installation guides Modify Date : 2014:12:07 11:46:35+08:00 Subject : Search through 700.000 manuals online & and download pdf manuals. Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : Provided By MANUALSLIB.COM - http://www.manualslib.com/ Description : Search through 700.000 manuals online & and download pdf manuals. Title : ManualsLib - Makes it easy to find manuals online! Creator Tool : pdftk 1.44 - www.pdftk.com Metadata Date : 2014:12:07 11:46:35+08:00 Producer : itext-paulo-155 (itextpdf.sf.net-lowagie.com) Document ID : uuid:81170acc-f54e-4e45-87af-b01896ca4982 Instance ID : uuid:516d3b06-8fd1-1047-b0e3-6671621b61e7 Page Count : 56EXIF Metadata provided by EXIF.tools