VITOCELL 100-B


Dual coil domestic hot water storage tank
79 and 119 USG / 300 and 450 ltr

Technical Data Manual
Model Nos. and pricing: see Price List

Product may not be exactly as shown

Vitocell 100-B
CVB Series
Vertical indirect-fired dual coil domestic hot water storage tank
made of steel with Ceraprotect enamel coating
One heat exchanger coil facilitates heat transfer from the solar
collectors to domestic hot water, a second heat exchanger coil
allows reheating of the water content by the hot water heating
boiler.

5285 656 - 01 03/2014

This tank version is not suitable
for steam heating applications.

Product Information

Product Information
Domestic hot water storage tank of corrosion
protected steel with built-in insulation made
of PUR Foam.
Fully hygienic, efficient and economical
domestic hot water production by solar
collectors and a hot water heating boiler.
Heat from the solar collectors is transferred
to the domestic hot water via the lower
tank coil.

Benefits at a glance:
H Corrosion-resistant tank with Ceraprotect
enamel coating ensures a long service life.
Additional cathode protection is provided
by a magnesium anode.
H The entire water content is heated by a
coiled 1”/25 mm diameter steel heat
exchanger surface which extends to the
bottom of the tank.
H Large heat exchanger surfaces allow fast
and even heating of the entire water
content, guaranteeing a high level of
domestic hot water comfort.

H For dual-mode DHW heating with solar
panels in conjunction with a boiler. The
solar energy gathered by the solar panels
is transferred to the DHW by the lower
indirect coil. For mono-mode DHW heating
with a boiler or heat pump - both indirect
coils can be connected in series.
H Certified to CSA Low Lead Content
Certification Program;
including US Safe Drinking Water Act,
NSF/ANSI 372 as well as other applicable
US State requirements.

H Increased energy savings thanks to highly
effective, foamed-in-place HCFC-free
insulation keeping standby losses at a
minimum.
H Two thermometers to show the DHW
temperature at the top of the tank and at
the midpoint of the tank.

5285 656 - 01

H The Vitocell-B 100 119 USG / 450 L
capacity tank is supplied with removable
soft PET insulation for easier handling.

2

VITOCELL 100-B

Product Information
Cross-Section

Highly effective foamed-in-place
hard PUR foam insulation (HCFC free, 79 USG / 300 ltr)
or soft PET insulation (119 USG / 450 ltr)
Domestic hot water

Two thermometers

Upper coildomestic hot water is reheated by boiler

Recirculation tapping

Steel domestic hot water tank
with Ceraprotect enamel

Lower coil connection for solar connectors

Inspection port/
cleanout opening

5285 656 - 01

Domestic cold water / drain

VITOCELL 100-B

3

Technical Data
Technical Data
For DHW production in conjunction with heating boilers,
and heating systems without low limit for dual coil operation

Suitable for heating systems with:
H max. working pressure on heat exchanger side up to 150 psig at
320°F/160°C
H max. working pressure on DHW water side of up to 150 psig at
210°F/99°C
H max. testing pressure on DHW side of 300 psig

Storage capacity

USG / ltr

79 / 300
upper *1

Coil
rate *3

Recovery
with a DHW temperature increase from 50 to 113 ºF/
10 to 45 ºC and a supply water temperature of . . . . . .

Recovery rate *3
with a DHW temperature increase from 50 to 140 ºF/
10 to 60 ºC and a supply water temperature of......

119 / 450
upper *1

lower *2

194ºF/90ºC

MBH / kW
GPH / ltr/h

106 / 31
181 / 53
160 / 47
239 / 70
201 / 761 344 / 1302 305 / 1154 454 / 1720

176ºF/80ºC

MBH / kW
GPH / ltr/h

89 / 26
151 / 44
169 / 640 286 / 1081

136 / 40
198 / 58
259 / 982 376 / 1425

158ºF/70ºC

MBH / kW
GPH / ltr/h

68 / 20
129 / 491

113 / 33
214 / 811

102 / 30
153 / 45
195 / 737 292 / 1106

140ºF/60ºC

MBH / kW
GPH / ltr/h

51 / 15
97 / 368

79 / 23
150 / 566

75 / 22
143 / 540

109 / 32
208 / 786

122ºF/50ºC

MBH / kW
GPH / ltr/h

38 / 11
71 / 270

62 / 18
117 / 442

55 / 16
104 / 393

82 / 24
156 / 589

194ºF/90ºC

MBH / kW
GPH / ltr/h

79 / 23
104 / 395

154 / 45
205 / 774

123 / 36
164 / 619

181 / 53
241 / 911

176ºF/80ºC

MBH / kW
GPH / ltr/h

68 / 20
91 / 344

116 / 34
154 / 584

102 / 30
136 / 516

151 / 44
200 / 756

158ºF/70ºC

MBH / kW
GPH / ltr/h

51 / 15
68 / 258

79 / 23
104 / 395

75 / 22
100 / 378

113 / 33
150 / 567

Insulation
Standby losses *4

lower *2

Hard PUR Foam

Soft PET insulation

7.8

9.5

25
633
28
705
68¾
1746
70½
1792
-

33½
850
36
918
77
1955
731/8
1860

352
160

452
205

MBH/24 h

Overall dimensions with insulation *5
Overall width (∅)

inches
mm
inches
mm
inches
mm
inches
mm
inches
mm

Overall depth
Overall height
Tilt height including insulation
Tilt height excluding insulation
Weight
Tank with insulation

lbs
kg

Heat exchanger coil liquid content

USG
ltr

1.6
6

2.6
10

2.3
9

3.3
12.5

Heat exchanger area

ft.2
m2

9.7
0.9

16.1
1.5

15
1.4

20.5
1.9

1”
1”
1”

1”
1”
1”

Connections

Coils
Domestic cold/hot water
Recirculation

∅” (male thread)
∅” (male thread)
∅” (male thread)

1”
1¼”
1”

*1

The upper coil is designated for connection to a hot water heating boiler or a heat pump.
The lower coil is designated for connection to solar collector panels or heat pumps.
*3 When planning for the recovery rate as stated or calculated, allow for the corresponding circulation pump.
The stated recovery rate is only achieved when the rated output of the boiler is equal to or greater than that stated under “Recovery
rate”.
*4 Measured values are based on a room temperature of 68°F / 20 ºC and a domestic hot water temperature of 149°F / 65 ºC and can vary
by 5%.
*5 For other dimensions, see illustration and table on page 5.
" For

4

information regarding other Viessmann System Technology componentry, please reference documentation of the respective product.

VITOCELL 100-B

5285 656 - 01

*2

Technical Data

79 USG / 300 ltr Tank
MA
DHW

Legend
IO
D
BWR
SCR

Section A-B
*1

TH

SW1

Y

TPV

BWS

BWR
SCS
c
d

e

f

IO

SW2

Total width

g
Total height

RT

*1

a
b

h

Øk

SCR

Total depth

Inspection and cleanout opening
Drain
Boiler water return (upper coil)
Solar collector return (lower coil) or
boiler return
BWS
Boiler water supply (upper coil)
SCS
Solar collector supply (lower coil) or
boiler supply
DCW
Domestic cold water
SW1*1 Sensor well for tank temperature
sensor of boiler control at BWS
level
SW2
Sensor well for the lower
thermometer at SCS level
DHW
Domestic hot water
RT
Recirculation tapping
TPV
Temperature and pressure relief
valve
MA
Protective magnesium anode
*1For

solar heating systems Viessmann
recommends placement of the DHW tank
temperature sensor of the solar control in
the solar collector return (SCR). This
requires a brass elbow with sensor well
included in the accessory pack.
The DHW tank temperature sensor of the
boiler control is placed in the SW1 sensor
well (see installation example on page 8).

DCW/D

DHW tank temperature sensor
in solar heating applications
79 USG / 300 ltr

Storage
capacity

USG /
ltr

79 /
300

a

inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm

3
76
10¼
260
34½
875
39
995
43¾
1115
53¼
1355
63
1600
13
333
4
101

b
c
d
e
f
g
h
k

5285 656 - 01

DHW tank temperature sensor for
solar application (included with
Solar control)
Brass elbow with sensor well
(accessory pack)
Solar collector return connection

VITOCELL 100-B

5

Technical Data

119 USG / 450 ltr Tank

Section A-B

DHW
TH
MA

Legend
IO
D
BWR
SCR

SW1*1
BWS

BWR

SW2

d

e

f

SCS

g
Total height

RT

Total width

b

k

h

c

SCR*1

a

DCW/D

Inspection and cleanout opening
Drain
Boiler water return (upper coil)
Solar collector return (lower coil) or
boiler return
BWS
Boiler water supply (upper coil)
SCS
Solar collector supply (lower coil) or
boiler supply
DCW
Domestic cold water
SW1*1 Sensor well for tank temperature
sensor of boiler control at BWS
level
SW2
Sensor well for the lower
thermometer at SCS level
DHW
Domestic hot water
RT
Recirculation tapping
TPV
Temperature and pressure relief
valve
MA
Protective magnesium anode
*1For

Total depth

DHW tank temperature sensor
in solar heating applications
119 USG / 450 ltr

solar heating systems Viessmann
recommends placement of the DHW tank
temperature sensor of the solar control in
the solar collector return (SCR). This
requires a brass elbow with sensor well
included in the accessory pack.
The DHW tank temperature sensor of the
boiler control is placed in the SW1 sensor
well (see installation example on page 8).

Storage
capacity

USG /
ltr

119 /
450

a

inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm

4¼
107
13¾
349
36 3/8
924
41
1044
48 3/8
1230
56 7/8
1444
70 ¼
1784
16 5/8
422
4
100

C
b
c
d
e
f
g
h
k

5285 656 - 01

DHW tank temperature sensor for solar
application (included with solar control
unit)
Brass elbow with sensor well
(accessory pack)
Solar collector return connection

6

VITOCELL 100-B

Technical Data
Pressure drop on heating water side

Domestic hot water pressure drop

20

4

10

3.2

8

2.4

6

40
32
24
20
16

1.6

4

8

1.2

3

0.8

2

0.4

1

4
3.2
2.4
2

500

5

12

Pressure drop

2

1.6
7 000
31

3.5

4 000
5 000
6 000
18
22
26

ltr/h

2.6

3 000
13

2.2

2 000
9

44 10000

800
1 000
3.5
4.4

2.2
2.6

500
600

1.2

5 000

8

80

4 000

30

ltr/h

22

12

18

120

3 000

40

13

160

2 000

50

16

9

60

20

800

24
240
200

1 000

80

4.4

32

600

40 100

C
400
320

Pressure drop

mbar

“ w.c.

mbar

“w.c.

of a single coil

GPM

Waterflow

GPM

79 USG / 300 ltr
119 USG / 450 ltr

Waterflow

Upper indirect coil, 300 ltr capacity
Lower indirect coil, 300 ltr and upper
indirect coil, 450 ltr capacity
Lower indirect coil, 450 ltr capacity

Domestic hot water draw rate

5285 656 - 01

Storage tank contents heated to 140ºF / 60ºC, boiler not reheating
Storage capacity

USG
ltr

79
300

119
450

Domestic hot water draw
Water with t = 140ºF / 60ºC (constant)

USG
ltr

32
110

53
220

37%

50%

Percentage tank volume

VITOCELL 100-B

7

Standard Equipment/Product Installation
Standard Equipment
Vitocell 100-B (79 USG / 300 ltr
capacity) DHW Tank
DHW tank made from steel with
Ceraprotect enamel coating.
– 2 welded sensor wells for DHW tank
temperature sensor, i.e. aquastat, and
the thermometer
– adjustable leveling bolts
– protective magnesium anode
– fitted thermal insulation made from
hard PUR foam
– threaded elbow with sensor well
The color of the epoxy-coated sheet
metal casing is Vitosilver.
The following are packed separately and
attached to the crate:
– 1 brass elbow with sensor well
– 1 Loctite package
– 1 temperature and pressure relief valve
– 2 thermometers °F / °C
– 7 brass adaptors (1”)
– 1 brass tee (1”)
– 1 brass hex bushing (1”x¾”)
– 1 brass cap (1”)

Vitocell 100-B (119 USG / 450 ltr
capacity) DHW Tank
DHW tank made from steel with
Ceraprotect enamel coating.
– 2 welded sensor wells for DHW tank
temperature sensor, i.e. aquastat, and
the thermometer
– protective magnesium anode
– fitted thermal insulation made from soft
PET insulation, packed separately
– threaded elbow with sensor well
– adjustable leveling bolts
– protective magnesium anode
The color of the plastic-coated thermal
insulation is Vitosilver.
The following are packed separately and
attached to the crate:
– 5 brass adaptors (1”)
– 2 brass adaptors (1¼”)
– 1 Loctite package
– 1 temperature and pressure relief valve
– 1 brass tee (1¼”)
– 1 brass elbow with sensor well
– 1 brass cap
– 2 thermometers °F / °C
– 1 plug (R1½”)

Product Installation
Domestic hot water connection
Domestic hot water supply
DHW recirculation line
DHW recirculation pump
Spring-loaded flow check valve
Discharge pipe
Pressure and temperature relief valve
Shut-off valve
Drain
Domestic cold water supply lines
Backflow preventer
Domestic cold water inlet
Precharged expansion tank
(required where backflow preventer is
installed; check local plumbing codes
and requirements)
Thermostatic mixing valve/anti-scald
valve for solar applications (field
supplied)

Due to the potentially high DHW
temperatures generated by the solar
heating system, the domestic hot
water temperature must be limited to a
maximum of 140°F/60°C by installing
a mixing device, e.g. a thermostatic
mixing valve. The mixing device does
not completely eliminate the risk of
scalding at the tap. The installation of a
mixing tap is required.

8

VITOCELL 100-B

5285 656 - 01

WARNING

System Design Guidelines
Installation example

HC Heating circuit
B
Oil/Gas-fired boiler
DCW Domestic cold water
DHW Domestic hot water
T&P Temperature and pressure relief valve

5285 656 - 01

Solar collector
Vitocell 100-B
Filling valve
Solar-Divicon (pumping station)
Recirculation pump
Anti-scald tempering valve

VITOCELL 100-B

9

System Design Guidelines
Sensor wells
The sensor wells are welded into the DHW
tank.
Ø7/8” / 21 mm
Ø5/8” / 16 mm

8” / 200 mm

Sensor wells for solar operation
For solar heating systems, Viessmann
recommends placement of the DHW tank
temperature sensor in the solar collector
return. This requires installation of a a brass
elbow with sensor well included in the
accessory pack.
c

Temperature and pressure
relief valve
A temperature and pressure relief valve
(T&P relief valve) is supplied with the tank.
The heating contractor must install the
valve on each tank in a method meeting
code requirements. If local codes require a
different relief valve, substitute the
manufacturer’s supplied valve. The tank is
approved for 150 psig. Maximum operating
pressure is 150 psig.
The T&P relief valve supplied with the tank
is tested under ANSI Z21.22 Code for Relief
Valves and Automatic Gas Shut-off Devices
for Hot Water Supply Systems.

Backflow preventers
Where backflow preventers are required, a
domestic water expansion tank installation
is recommended in the cold water inlet
piping before the cold water enters the
Vitocell. For the backflow device, observe
local plumbing codes and regulations.

e
d
Dimension
a
b
c
d
e

inches
mm
inches
mm
inches
mm
inches
mm
inches
mm

79/300
6 1/4
160
5.9
150
7/8”
22
¼
6.5
1/
3
8

119/450
8.7
220
7.9
210
7/8”
22
¼
6.5
1/
3
8

Our warranty for domestic hot water tanks
states that the water to be heated must be
of drinking (potable) water quality and that
any water treatment equipment in use must
function correctly.
Viessmann accepts no responsibility for
damage howsoever caused and reserves the
right to withdraw the product warranty if the
product has been improperly installed or
misapplied by the installer, contractor or end
user. In order to qualify for product warranty,
strict adherence to the installation and
service manuals must be assured. In the
event that Viessmann non-approved
components are utilized, Viessmann reserves
the right to withdraw all expressed or implied
warranties without written notice.
The water to be heated with the Vitocell
must be drinking (potable) water quality. If
the tank is used to heat other media, the
warranty will be null and void. Damage
resulting from excessive pressure or
temperature is clearly not the responsibility
of Viessmann.

Watts Model
40XL-8

150 psig
(US and Canada)

ASME pressure
steam rating

1438 MBH

The amount of chloride and sulfate
acceptable to the tank is limited. In areas
where high concentrations of chloride and
sulfate are present in drinking water, please
consult Viessmann for directions.

CSA temperature
steam rating

205 MBH

For full warranty details, please read the
product warranty card.

Relief
temperature

210ºF (99ºC)

Inlet thread

¾” male

Outlet thread

¾” female

b
a

Warranty excerpt

Heating water supply temperature
over 230ºF / 110ºC

5285 656 - 01

These operating conditions require the
installation of an additional safety high limit
into the DHW storage tank, preventing the
domestic hot water temperature from rising
above 203 ºF/ 95 ºC. A domestic hot water
tempering valve must be used.

10

VITOCELL 100-B

5285 656 - 01
VITOCELL 100-B

11

12

VITOCELL 100-B

5285 656 - 01

Technical information subject to change without notice.

Printed on environmentally friendly
(recycled and recyclable) paper.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 12
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : 76556cdc-aae5-11e3-0000-f9391d69f5aa
Producer                        : GPL Ghostscript  9.0
Keywords                        : ()
Modify Date                     : 2014:03:10 15:26:57-04:00
Create Date                     : 2014:03:10 15:26:57-04:00
Creator Tool                    : PDFCreator Version 1.2.0
Document ID                     : 76556cdc-aae5-11e3-0000-f9391d69f5aa
Format                          : application/pdf
Title                           : 5285 656 - 01
Creator                         : ebem
Description                     : ()
Author                          : ebem
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu