Viessmann Vitola 200 Technical Manual 5167 403 V1.6
2015-08-26
: Viessmann Viessmann-Vitola-200-Technical-Manual-802291 viessmann-vitola-200-technical-manual-802291 viessmann pdf
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
VITOLA 200 Hot water heating boiler without low limit 83 to 300 MBH / 24 to 88 kW Technical Data Manual Model Nos. and pricing: see Price List Vitola 200 with Vitoflame Burner and Vitocell-H 300 domestic hot water tank Vitola 200 with Vitoflame Burner, boiler stand and Vitocell-V 300 domestic hot water tank Vitola 200 VB2 Series Oil-/Gas-Fired Boiler for hydronic heating systems with modulating boiler water temperatures without low limit with biferral heating surfaces of cast iron/steel Heating input: 83 to 300 MBH 24 to 88 kW 5167 403 v1.6 04/2008 Oil-fired Product Information Vitola 200 High quality at an affordable price: The double-wall sandwiched heat exchanger surface of the Vitola 200 is a milestone in the history of heating technology. The Vitola 200 combines comfort with energy savings. The benefits at a glance: H Biferral heat exchanger of cast iron and steel for high operational reliability and a long service life. H Reduced emissions with the Viessmann Chassis or Vitoflame Burner. H Saves energy and preserves the environment via low boiler water temperatures; cold start ability; A.F.U.E. of up to 87.4% (oil-fired version). H Short installation times due to the Viessmann Fastfix Installation System. Save up to 50% of the installation time when installing boiler panelling and control. Simple assembly is achieved with components which merely snap together, making special tools unnecessary. The biferral sandwiched heat exchanger of cast iron and steel offers high operational reliability and a long service life 5167 403 v1.6 H Optimal temperature modulation due to wide water passageways and a large water content. H Straight-forward installation and start-up – Burners supplied by Viessmann are tested with a combustion analyzer at operating temperature and matched to the boiler input in the factory. 2 Product Information Cut-Away Section Biferral sandwiched heat exchanger surface of cast iron and steel offers high operational reliability and a long service life Removable stainless steel combustion chamber Viessmann Vitoflame 100 Burner Vitotronic 200 – indoor/outdoor digital boiler and heating system control 5167 403 v1.6 3” / 75 mm boiler shell insulation 3 Technical Data Technical data Model No. Boiler Model input CSA gas rating *1 output input CSA oil rating output Net I=B=R rating *2 for gas for oil for NG for LP for oil A.F.U.E. *3 Dimensions Length Width Height VB2-22 VB2-33 VB2-40 VB2-50 VB2-63 90 26 75 22 116 34 97 28 146 42 122 35 185 54 154 45 238 69 198 57 300 88 249 73 MBH kW MBH kW 83 24 72 21 107 31 92 27 135 39 116 34 170 50 146 43 219 64 189 55 300 88 258 76 MBH kW MBH kW 65 19 63 18 84 25 80 23 106 31 101 30 134 39 127 37 172 50 164 48 217 64 224 66 % % % 84.5 86.0 87.1 84.0 85.8 87.2 84.0 85.8 87.2 84.0 85.8 87.3 83.9 85.7 87.4 83.9 85.7 87.1 inches mm inches mm inches mm 23¼ 589 21¼ 537 27¾ 706 25¾ 655 22¼ 565 28½ 726 32¼ 817 23½ 599 29¼ 743 32¼ 817 26½ 674 32¼ 819 37¾ 956 27¾ 702 33½ 853 42 1070 27¾ 702 33½ 853 inches mm inches mm inches mm inches mm inches mm inches mm 43¾ 1112 25¼ 639 32¾ 830 37 940 45¾ 1160 9¾ 250 46¼ 1178 26¼ 667 33½ 850 37¾ 960 46½ 1180 9¾ 250 52¾ 1340 27½ 701 34 865 38¼ 975 47 1195 9¾ 250 53¼ 1350 30½ 776 37 940 41¼ 1050 50 1270 9¾ 250 58½ 1489 30½ 776 38½ 975 42¾ 1085 51½ 1305 9¾ 250 63 1603 30½ 776 38½ 975 42¾ 1085 51½ 1305 9¾ 250 inches mm inches mm inches mm 26 658 – 26 658 – – – 26 658 31 790 37¼ 947 – – 26 658 31 790 – 31 790 37¼ 947 31 790 37¼ 947 lbs kg lbs kg 287 130 381 173 335 152 434 197 430 195 542 246 573 260 697 316 739 335 866 393 809 367 941 427 *4 Total width Total height (operation) - Height 1 *5 (control unit in position for operation) - Height 2 *5 (control unit in position for servicing) Height of boiler stand Height of Vitocell-H under boiler - 42 to 53 USG / 160 to 200 ltr - 92 USG / 350 ltr - 120 USG / 450 ltr Weight boiler shell Total weight (boiler with insulation, burner and boiler control) Boiler water content USG ltr 18.5 70 23.2 88 31.2 118 37.0 140 52.6 199 59 223 Max. operating pressure psig 30 30 30 30 30 30 Boiler water connections Supply and return Safety supply (Safety Header) Safety return, drain valve inches inches inches 1½ 1 1 1½ 1 1 1½ 1 1 1½ 1 1 1½ 1 1½ 1½ 1 1½ *1 Propane burners have same input/output as natural gas burners. I=B=R rating based on piping and pick-up allowance of 1.15. *3 Annual Fuel Utilization Efficiency with optional stack damper. *4 Overall dimensions with Viessmann Vitoflame 100 Burner installed. *5 See page 6. *2 Net 4 5167 403 v1.6 Overall dimensions Total length VB2-18 MBH kW MBH kW Technical Data Technical data Model No. Boiler Model Flue gas *6, temperature (gross)*7 at H 104°F / 40°C boiler water temp. *9 °F °C °F H 167°F / 75°C boiler water temp. °C lbs/h Flue gas mass flow kg/h Vent pipe Boiler vent outer ∅ inches VB2-18 VB2-22 VB2-33 VB2-40 VB2-50 VB2-63 293 145 329 165 68 31 293 145 329 165 84 38 293 145 329 165 123 56 293 145 329 165 150 68 293 145 329 165 187 85 293 145 329 165 236 107 5 5 6 6 7 7 Flue gas volume, boiler USG ltr 10.3 39 14.0 53 20.6 78 29.1 110 41.5 157 45.7 173 Required flue draft “w.c. -0.02 -0.02 -0.02 -0.02 -0.02 -0.02 *8 *9 *6 Combustion results are based on 11.0% to 13.0% CO2 with fuel oil #2, 9.5% to 10.2% with natural gas, or 10.0% to 11.5% CO2 with propane, and a hot water heating system supply temperature of 167°F / 75°C, return 140°F / 60°C. *7 Measured flue gas temperature with combustion air temperature of 68°F / 20°C. *8 Ensure compatibility during burner selection. *9 Ensure compatibility with chimney system. The chimney vent system must be suitable for the application (low flue gas temperature with possible condensation), see page 10. For information regarding other Viessmann System Technology componentry, please reference documentation of the respective product. 5167 403 v1.6 " 5 5¾” / 145 mm Technical Data BWS Overall height BTS BWS BWR BWR FGC Height Height 2 Height 1 SS SR/BD 9¾” 250 mm 2¾” / 70 mm Width Overall width 4” / 100 mm Length 6” / 154 mm Overall length VB2-18 to -33=161/8” / 410 mm VB2-40 to -63=175/8” / 448 mm Boiler Model VB2 a inches mm inches mm inches mm inches mm inches mm inches mm b c d e f With DHW tank under the boiler USG ltr g inches mm inches mm inches mm inches mm inches mm inches mm h k l m n *1 Support -18 -22 30 761 13¼ 338 5¾ 144 7¾ 195 5½ 141 19¼ 488 30¾ 781 13¼ 338 5½ 138 8¼ 210 5 125 19¾ 503 -33 -40 -50 -63 31½ 797 13¼ 338 5¾ 144 8¾ 225 4¼ 110 20 511 34½ 874 13½ 342 5¾ 144 10 254 3¼ 84 21¼ 542 35¾ 908 14½ 370 5¾ 144 10½ 268 3¼ 85 24½ 620 35¾ 908 14½ 370 5¾ 143 10½ 268 3¼ 85 24½ 620 42 and 53 42 and 53 53 92 53 92 120 160 and 200 160 and 200 200 350 200 350 450 *1 61¼ 1555 58¾ 1490 26 658 31½ 799 39¼ 996 45 1146 62 1575 59½ 1510 26 658 30¾ 783 39¼ 996 45¾ 1161 62½ 1590 60 1525 26 658 30¼ 768 39¼ 996 46 1169 67¾ 1720 65¼ 1655 31 790 35½ 900 44½ 1128 51¼ 1301 65¼ 1665 63 1600 26 658 29¼ 742 39¼ 1000 47¼ 1200 70¾ 1795 68 1730 31 790 34½ 874 44½ 1132 52½ 1332 76¾ 1952 74¼ 1887 37¼ 947 40½ 1031 50¾ 1289 58½ 1489 Bars are necessary for 120 USG / 450 ltr tanks; dimensions “g” through “n” include 2¼” / 57 mm to account for the height of the Support Bars. 6 92 120 92 120 350 450 *1 350 450 *1 72 1830 69½ 1765 31 1790 34½ 1875 45¾ 1160 55½ 1410 78¼ 1987 74¼ 1932 37¼ 947 40½ 1031 51¾ 1317 61¾ 1567 72 1830 69½ 1765 31 1790 34½ 1875 45¾ 1160 55½ 1410 78¼ 1987 74¼ 1932 37¼ 947 40½ 1031 51¾ 1317 61¾ 1567 5167 403 v1.6 Dimensions Technical Data Legend BD Boiler Drain BTS Boiler Temperature Sensor BWR Boiler Water Return BWS Boiler Water Supply FGC Flue Gas Collar SR Safety Return SS Safety Supply SS BWS BWS BWR BWR 5¾” / 145 mm Boiler Stand Vitocell-H FGC SR/BD Mounting the Vitola 200 on a Vitocell-H The Vitola 200 can be mounted on a Vitocell-H as shown to reduce the footprint of heating equipment in the mechanical room. Do not attempt to install combinations not listed in the Price List. Boiler/Tank Compatibility Order numbers are listed for boiler/tank combinations requiring support bars. Support bars may be required when mounting a Vitola 200 boiler on a Viessmann Vitocell-H Series tank. Refer to the following chart to determine whether support bars are required for your application. Certain boilers (listed with a “z” in the chart) are directly compatible with the Vitocell-H tank and thus do not require additional hardware. Combinations listed with “n.a.” are incompatible. Do not attempt to install these combinations. For more information see Viessmann Price List. Boiler/Tank Compatibility Vitocell-H 100 DHW storage tank Vitola 200 VB2-18/-22 VB2-33 VB2-40 VB2-50/-63 Vitocell-H 300 DHW storage tank CHA-160 CHA-200 EHA-160 EHA-200 EHA-350 EHA-450 z z n.a. n.a. z z z n.a. z z n.a. n.a. z z z n.a. n.a. z z z n.a. n.a. Z001 060 Z001 060 5167 403 v1.6 Order No. = Support bars are required. z = Support bars are not required. Boiler/tank are directly compatible. n.a. = Boiler/tank are incompatible. Neither mounting with support bars, nor direct-mounting possible. 7 Technical Data Recommended Minimum Clearances for Service Combustion chamber insert Boiler Vitocell-H domestic hot water storage tank *2 Sensor well for storage tank VB2 Boiler Model a *1: -18 -22 -33 -40 -50 -63 Necessary clearance in front of the boiler for maintenance and service inches mm 24½ 620 26¾ 680 33½ 850 33½ 850 36½ 920 43 1090 Dim b: Necessary clearance beside the boiler Ensure sufficient clearance if installing Divicon inches mm 24 600 24 600 24 600 24 600 24 600 24 600 Dim c: Necessary clearance behind a Vitocell-H installed below the boiler inches mm 16¾ 425 16¾ 425 17¾ 450 17¾ 450 17¾ 450 17¾ 450 Dim d: Ensure adequate clearance for Divicon or other accessories; minimum clearances (no Vitocell-H installed below the boiler) inches mm 24 600 24 600 24 600 24 600 24 600 24 600 inches mm 24 600 24 600 24 600 24 600 24 600 24 600 Dim Top: *1 *2 This clearance is required for service work. Viessmann strongly recommends maintaining 48” / 1200 mm front clearance on all models. The Vitola 200 can be mounted on a Vitocell-H as shown to reduce the footprint of heating equipment in the mechanical room. Do not attempt to install combinations not listed in the Price List. Minimum Clearances to Combustibles For typical installations, Viessmann recommends installing the boiler with clearances as published on page 10 under Recommended Minimum Clearances for Service. min. 0” / 0 mm service clearance 48” 1220 mm* min. 6” 150 mm Boiler Model VB2 Rear Sides Flue 8 -18 -22 -33 -40 -50 -63 inches mm 6 150 6 150 6 150 6 150 6 150 6 150 inches mm 0 0 0 0 0 0 0 0 0 0 0 0 (oil) inches mm 9 230 9 230 9 230 9 230 9 230 9 230 (gas) inches mm 6 150 6 150 6 150 6 150 6 150 6 150 5167 403 v1.6 Standard installation (top view) Technical Data Standard Equipment / Boiler Control Alternatives Waterside Flow (primary circuit) Pressure drop mbar “w.c. The Vitola 200 is designed for closed loop, forced circulation hot water heating systems only. 20 50 16 40 12 30 8 20 4 10 3.2 8 2 5 1.6 4 1.2 3 0.8 2 0.4 1 0.5 2.2 Water flow Legend VB2-18 to -33 VB2-40 to -63 1 2 3 4.4 9 13 4 5 6 7 m3/h 18 22 26 31 GPM Standard Equipment Note: Boiler controls and burners are purchased separately. Please see Price List for details. 5167 403 v1.6 Boiler shell with combustion chamber door 1 carton with insulating jacket and 1 cleaning brush 1 set of boiler ID hardware (coding card and technical literature) 1 installation fittings carton with safety header (c/w 30 psig pressure relief valve, air vent and pressure gage), drain valve, and installation fittings 1 carton with boiler control 1 carton with: Viessmann Vitoflame Burner (c/w burner hood and barometric damper) or Riello Burner (c/w barometric damper) Boiler Control Alternatives Vitotronic 100, KK10 standard boiler control for high temperature heating systems Vitotronic 100, KW10 standard boiler control for high temperature heating systems with indoor/outdoor system control Vitotronic 200, KW2 for multiple temperature heating systems with or without a mixing valve with indoor/outdoor digital boiler and heating system control Vitotronic 300, KW3 for multiple temperature heating systems with up to two mixing valves with indoor/outdoor digital boiler and heating system control 9 System Design Considerations System Design Considerations Chimney Combustion air supply Water quality For proper operation of the Vitola boiler, all products of combustion must be safely vented to the outdoors, while ensuring that flue gases do not cool prematurely. It is critical that the chimney system be properly designed to handle the flue gas temperatures which the Vitola boiler produces. Flue gases which cool too quickly produce condensation which leads to damages if the chimney diameter is too large and the chimney system is not well insulated. If a calculated chimney diameter lies between two values, the larger diameter should be selected. The boiler must not be located in areas or rooms where chemicals containing chlorine, bromine, fluorine, or other corrosive chemicals are stored. Examples include refrigerants, bleach, paint, paint thinner, hair spray, cleaning solvents, water softener salt, etc. The combustion air must not be contaminated with the above mentioned, or other aggressive or corrosive chemicals. Treatment for boiler feed water should be considered in areas of known problems, such as where a high mineral content and hardness exist. In areas where freezing might occur, an antifreeze may be added to the system water to protect the system. Please adhere to the specifications given by the antifreeze manufacturer. Do not use automotive silicate based antifreeze. Please observe that an antifreeze/water mixture may require a backflow preventer within the automatic water feed and influence components such as diaphragm expansion tanks, radiation, etc. A 40% antifreeze content will provide freeze-up protection to -10°F / -23°C. Do not use antifreeze other than specifically made for hot water heating systems. System also may contain components which might be negatively affected by antifreeze. Check total system frequently when filled with antifreeze. Advise system operator/ultimate owner that system is filled with a glycol mix. The chimney connection length between the boiler vent pipe collar and the chimney must be installed with insulation. Viessmann recommends consulting a reputable chimney installer for advice in project-specific circumstances. Barometric damper must be used! For Canadian oil installations only, a blocked vent safety shut-off switch must be installed. Warranty Our warranty does not cover damages resulting from the following: – installation or service by unqualified and not licensed personnel – corrosion caused by flue gas condensation due to low boiler water and/or return water temperatures – operation with contaminated fill and supplementary feed water For detailed warranty information, please read warranty sheet supplied with product. 10 Consult Viessmann with uncertainties in regard to a suitable boiler installation location. This boiler/burner unit needs clean fresh air for safe operation and must be installed so that there are provisions for adequate combustion and ventilation air. For oil-fired boilers, use the “Installation Code for Oil Burning Equipment CAN/CSA-B139” (Canada), or NFPA 31 (USA) and/or provisions of local codes. For gas or propane, use the “Natural Gas Installation Code CAN/CSA-B149.1 or B149.2” (Canada), or “National Fuel Gas Code ANSI Z223.1” (USA), and/or provisions of local codes. The sizing methods outlined in the above codes should be used when installing a round duct to supply combustion air from the outside. Observe local jurisdictional requirements. System layout The boiler water temperature limit is factory set to 167°F / 75°C. The boiler water temperature limit can be increased by altering the adjustable high limit to increase the supply water temperature. To minimize piping losses of the system, however, we recommend that the radiation and domestic hot water production in the system be designed for a 158°F / 70°C boiler supply water temperature (new systems). The heating contractor must provide an MSDS (Material Safety Data Sheet) for the antifreeze used to the system operator/ultimate owner. Oxygen diffusion barrier underfloor tubing The boiler warranty does not cover leaks resulting from corrosion caused by the use of underfloor plastic tubing without an oxygen diffusion barrier. Such systems must have the non-oxygen diffusion barrier tubing separated from the boiler with a heat exchanger. Viessmann recommends the use of underfloor plastic tubing with an oxygen diffusion barrier. Low water cut-off A low water cut-off may be required by local codes. If boiler is installed above the radiation level, a low water cut-off device of approved type must be installed in all instances. An approved type low water cut-off device must be provided by the heating contractor. Do not install an isolation valve between the boiler and the low water cut-off. 5167 403 v1.6 Intermediate section The intermediate (vertical and horizontal) section of venting between the boiler vent pipe collar and the chimney must be of identical diameter as the vent connection of the boiler. Use the shortest possible path between the boiler and the chimney. A maximum of two elbows may be installed in the intermediate section. Avoid the use of two level 90° elbows. The intermediate section must be sealed pressure tight at the boiler vent pipe collar and at the chimney connection. Ensure any test port for combustion values is sealed as well. Boiler should never be installed in areas where excessive dust, high humidity, or risk of frost exist. Ensure adequate ventilation and supply of fresh combustion air. Installation Examples Installation Examples Important! These examples depict possible piping layouts for Viessmann product equipped with Viessmann System Technology. For boiler and tank combinations, please install only the feasible combinations listed in the Price List. These are simplified conceptual drawings only! Piping and necessary componentry must be field verified. Proper installation and functionality in the field is the responsibility of the heating contractor. Without mixing valve e.g. with Vitotronic 100, KK10 5167 403 v1.6 Heating circuit Spring-loaded flow check valve Circulation pump Safety header with automatic air vent, pressure relief valve, and pressure gage Expansion tank Domestic hot water storage tank (indirect-fired) DHW Pump Module The installation of the check valve to restrict gravity circulation in the heating supply pipe prevents uncontrolled heat flow to the heating system by gravity during priority switching of domestic hot water heating or during summer operation. 11 Installation Examples With one low-temperature circuit with 3-way mixing valve, one high-temperature circuit, and with domestic hot water production e.g. with Vitotronic 200, KW2 combined with one Mixing Valve Actuator Accessory Kit Heating circuit Spring-loaded flow check valve Circulation pump Safety header with automatic air vent, pressure relief valve, and pressure gage Expansion tank Domestic hot water storage tank (indirect-fired) 3-Way mixing valve 4-Way mixing valve With two low-temperature circuits with mixing valves, one high-temperature circuit, and with domestic hot water production 5167 403 v1.6 e.g. with Vitotronic 300, KW3 combined with two Mixing Valve Actuator Accessory Kits 12 Installation Examples Underfloor heating system with one low-temperature circuit with 3-way mixing valve, and system separation e.g. with Vitotronic 200, KW2 combined with one Mixing Valve Actuator Accessory Kit 5167 403 v1.6 Heating circuit Spring-loaded flow check valve Circulation pump for heating circuit Safety header with automatic air vent, pressure relief valve, and pressure gage Expansion tank Heat exchanger Circulation pump for heat exchanger Pressure relief valve 13 14 5167 403 v1.6 15 5167 403 v1.6 Printed on environmentally friendly (recycled and recyclable) paper. Technical information subject to change without notice. 16 Viessmann Manufacturing Company Inc. 750 McMurray Road Waterloo, Ontario • N2V 2G5 • Canada Tel. (519) 885-6300 • Fax (519) 885-0887 www.viessmann.ca • info@viessmann.ca 5167 403 v1.6 Viessmann Manufacturing Company (U.S.) Inc. 45 Access Road Warwick, Rhode Island • 02886 • USA Tel. (401) 732-0667 • Fax (401) 732-0590 www.viessmann-us.com • info@viessmann-us.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2008:04:02 19:36:05Z Modify Date : 2008:05:02 11:28:06-03:00 Page Count : 16 Creation Date : 2008:04:02 19:36:05Z Mod Date : 2008:05:02 11:28:06-03:00 Producer : Acrobat Distiller 5.0 (Windows) Author : chih Metadata Date : 2008:05:02 11:28:06-03:00 Creator : chih Title : 5167 403 v1.6EXIF Metadata provided by EXIF.tools