Vigil Health Solutions WRX01 Low Power Transmitter User Manual

Vigil Health Solutions Inc Low Power Transmitter Users Manual

Users Manual

Download: Vigil Health Solutions WRX01 Low Power Transmitter User Manual
Mirror Download [FCC.gov]Vigil Health Solutions WRX01 Low Power Transmitter User Manual
Document ID713307
Application ID4teADCn+B9tKYfr0TBtPqQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize8.53kB (106581 bits)
Date Submitted2006-10-09 00:00:00
Date Available2006-10-09 00:00:00
Creation Date2006-08-21 16:39:59
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2006-08-21 16:39:59
Document TitleMicrosoft Word - WRX & WSRX Installation Instructions.doc
Document CreatorPScript5.dll Version 5.2
Document Author: jseiler

Wireless Receiver Installation Instructions
Wireless Receiver and Server
WRX & WSRX
Description
The Wireless Receiver (WRX) receives wireless transmissions from wireless devices and
communicates the data back to the central computer via the network cable. Wireless Receivers are
connected in series using a CAT5 cable and are terminated with RJ45 modular plugs. One Wireless
Receiver covers an area of approximately 100 feet square depending on building construction. The
Wireless Server Receiver (WSRX) is a variation of the Wireless Receiver that controls the wireless
portion of the communications. Typically one WSRX is required per building.
Enclosure Dimensions
5.5” x 3” x 1”
Antenna
6.25” Detachable Nearson 900MHz ISM Band. Model 161.
Cable Type
CAT5 or CAT5E 4 Pair 24AWG
Connectors
RJ45 Modular Plug (AMP)
Mounting Instructions
Screw mount to wall or ceiling using mounting holes and appropriate mounting hardware for
location. Mounting hardware not supplied.
Typically mounted above the ceiling tile in a corridor. Mount vertically on the wall above the
ceiling tile, with the antenna pointing downward. Antenna does not need to protrude below tile.
Alternately, receivers can be mounted below the ceiling or on the ceiling. See below for mounting orientation options. If
mounting on a horizontal surface a 90-degree antenna will be required.
Screw antenna onto WRX. Position 90-degree antenna vertically as appropriate.
Do not mount Wireless Receivers on or near metal objects (HVAC, I Beams, etc) or electrical devices (motors, high
voltage switching, etc) as they can interfere with the wireless signals
WRX with 90° antenna
WRX with straight antenna
Vigil Health Solutions Inc.
2102 - 4464 Markham Street * Victoria, BC * Canada * V8Z 7X8
Phone: 250.383.6900
Toll Free: 1.877.850.1122
Fax: 250.383.6999
Web: www.vigil.com
Revised: June 26, 2006
Page 1
Wireless Receiver Installation Instructions
Wiring and Connections
1 Orange/ White
2 Orange
3 Green/ White
4 Blue
5 Blue/ White
6 Green
7 Brown/ White
8 Brown
Conductor
Orange/ White
Orange
Green/ White
Blue
Blue/ White
Green
Brown/ White
Brown
Use
+ 24 VDC
+ 24 VDC
+ 24 VDC
DATA HI
DATA LO
GND
GND
GND
RJ45 Standard Pinout
Hook is underneath
Installation Instructions
1.
Terminate incoming and outgoing CAT5 cables on RJ45 modular plugs as shown above.
approved equivalent. Ensure cables are labelled appropriately.
Use supplied AMP plugs or
2.
After connecting the modular plugs on both ends of the cable, use an approved network cable tester to verify the connections
on both ends. All pins must be connected straight through.
3.
Once both ends of the cable are tested, plug the cable coming from the direction of the central equipment into the socket
marked “IN” and plug the cable going to the next receiver into the socket marked “OUT”.
4.
Set dipswitches as follows:
a.
If receiver is at the end of the line (no outgoing run) set the Terminating Resistor to ON by turning the switch labelled
“T” toward the base of the unit (labelled ON)
b.
If the receiver is a WSRX (Server) set the unit to Server mode by turning the switch labelled “S” toward the base of
the unit (labelled ON)
CAN Bus Communication
LED
Wireless Communication
LED
Receiver ID
Turn T Switch to ON if at
end of line
Turn S Switch to ON if
setting to a Server
Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
Vigil Health Solutions Inc.
2102 - 4464 Markham Street * Victoria, BC * Canada * V8Z 7X8
Phone: 250.383.6900
Toll Free: 1.877.850.1122
Fax: 250.383.6999
Web: www.vigil.com
Revised: June 26, 2006
Page 2
Wireless Receiver Installation Instructions
PHYSICAL
Height
Width
Depth
Weight (with antenna)
Enclosure
Temperature Ratings
Operating:
Storage/Transport
139.7mm (5.5”)
76.2mm (3”)
25.4mm (1”)
141 grams
High impact white plastic enclosure
ELECTRICAL
Operating Voltage
Wireless
Operating Current
10-40V DC
900MHz FHSS Transceiver
35mA, 85mA burst
WRX01 – FCC ID UI6-WRX01
-0°C to 50°C (32°F to 122°F)
-55°C to 85°C (-67°F to 185°F)
WSRX01 – FCC ID KQL-AC4490
Compliance: This Device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any interference received, including
interference that may cause undesired operation.
Warning: This equipment has been approved for portable
applications where the equipment can be used in direct contact
with the human body. Excessive RF exposure should be
avoided.
Limited Warranty
®
®
Vigil Health Solutions Inc. (Vigil) warrants all products bearing the Vigil name (“the Product” or “Products”) to be in conformance with specifications
and free from defects in materials and workmanship for a period of one (1) year (unless otherwise stated) from date of shipment and will repair or
replace (at our option), any unit that is found to be defective and returned to us under warranty.
To exercise the warranty the product must be returned to Vigil freight prepaid and insured. Vigil reserves the right to make the final decision whether
there is a defect in materials or workmanship, and whether or not the product returned is within the warranty.
This warranty does not cover damage due to normal wear and tear, improper installation, accident or tampering, misuse or neglect, or where goods
have been subjected to operating or environmental conditions exceeding those stated in the applicable specifications and extends to include floods,
fire, lightening and any other such acts of nature.
This warranty shall apply to the Product only. All other products distributed by Vigil and made by others are covered by the manufacturer’s warranty.
All products, accessories, or attachments of others used in conjunction with the Product, including batteries, shall be covered solely by their own
warranty, if any. Vigil shall not be liable for any damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially, or otherwise,
caused by the malfunction of the Product due to products, accessories, attachments of others, including batteries, used in conjunction with the
Products.
The foregoing warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities, whether written, oral, express or implied or
arising under law. In no case shall Vigil be liable to anyone for any consequential or incidental damages for breach of this warranty or any other
warranties whatsoever, as aforesaid.
Vigil shall have no liability for any death, personal and/or bodily injury and/or damage to property or other loss whether direct, indirect,
incidental, consequential, or otherwise based on a claim that the Product failed to function. However, if Vigil is held liable, whether directly or
indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of the cause or origin, Vigil’s maximum liability shall not
in any case exceed the purchase price of the Product, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete
and exclusive remedy against Vigil.
Vigil Health Solutions Inc. reserves the right to modify the appearance, operation and functionality at its discretion.
Vigil Health Solutions Inc.
2102 - 4464 Markham Street * Victoria, BC * Canada * V8Z 7X8
Phone: 250.383.6900
Toll Free: 1.877.850.1122
Fax: 250.383.6999
Web: www.vigil.com
Revised: June 26, 2006
Page 3

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2006:08:21 16:39:59-07:00
Create Date                     : 2006:08:21 16:39:59-07:00
Format                          : application/pdf
Title                           : Microsoft Word - WRX & WSRX Installation Instructions.doc
Creator                         : jseiler
Document ID                     : uuid:eb8e83ad-124f-497c-8c7e-5387df4bc0a8
Instance ID                     : uuid:a177f848-8953-4252-ba28-e07e53ee11a9
Page Count                      : 3
Author                          : jseiler
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UI6-WRX01

Navigation menu