    1 /  13  深圳理思科技有限公司 Visiomed Technology Co., Ltd.          EAR/FOREHEAD INFRARED THERMOMETER                            BW-MTX1
    2 /  13  深圳理思科技有限公司 Visiomed Technology Co., Ltd.  THE MANUFACTURER RESERVES THE RIGHT TO MODIFY THE PRODUCT TECHNICAL SPECIFICATIONS WITHOUT PRIOR NOTICE.  Find out how to install and use the BewellConnect APP by visiting our website at   https://bewell-connect.com/en/applications-support/    Dear Customer, Thank you for purchasing MyThermo Pocket Infrared Ear/Forehead Thermometer BW-MTX1, by Visiomed. We hope that you enjoy using it and recommend reading this user guide carefully.  1. PRODUCT DESCRIPTION                                                                     2. SAFETY INSTRUCTION It is important to read all the warnings and precautions in this manual. They are for your safety, to prevent injuries and avoid situations that could damage the device.   Consult your doctor, if you have a serious illness or if you want to know more about using this medical device.  2.1 Warning - Do not use the unit to measure temperature near the air outlet of air fan or air condition. - Do not use the unit out door or in strong sunshine. - It is recommended to take 3 measurement each time, subject to the data displayed most. - The unit will shut down automatically in 15s after measurement finished if no other operation. - Do not leave this unit within the reach of children. A self-measurement taken forcibly by children can damage their ear. In the event of accidental ingestion of the battery or the protective film, see a physician immediately. Item ① Measurement button ② IR Probe   ③ Forehead temperature cap ④ Window of the probe ⑤ LCD display ⑥ Battery ⑦ Battery compartment ⑧ ℃/℉ button ⑨ MEM button ⑩ Battery cover
    3 /  13  深圳理思科技有限公司 Visiomed Technology Co., Ltd. - The measurement results are for informational purposes only. If unsure about your results, please contact your physician. - Do not use the unit if the probe is damaged. - This product should not encourage you to self-medicate or adapt your treatment   - Stop using the unit if any pain occurs. There is a risk of damaging the ear canal.   - It is not recommended to use the device on patients with ear diseases such as otitis externa and tympanitis. - Do not use the unit in a wet ear canal, such as after swimming or after a bath. There is a risk of damaging the ear canal. - Do not touch or blow on the infrared sensor. A dirty or damaged infrared sensor may cause inaccurate results. 2.2 Caution  Constraints before taking the temperature:  - For a forehead temperature reading (centre forehead), take care to brush away the hair, wipe any sweat off the brow, avoid air flows, (e.g. supplemental oxygen, air conditioning, etc.). - To measure the tympanic temperature, make sure that the ear canal is clean, as an ear with excess wax can give inaccurate readings. - If there is sweat on forehead or use ice to cool the temperature may cause the measuring temperature lower than its real value, do not use the unit under this circumstance.  Please contact your doctor when the unit is warning after measuring. High fever or fever in long time should go to hospital, especially for infants and children.  2.3 General precautions - Use this unit only for its intended purpose as described in this manual. - Follow the maintenance instructions specified in this manual. - This device is designed for external use. - Use and storage: Refer to the technical features (range of room temperature, relative humidity, atmospheric pressure).   - This unit should always be stored in a clean, dry place. - Do not expose this unit to sunlight or water. - Do not use this unit outdoors. - Do not expose this unit to electrical shocks. - Never drop this unit. - Do not touch the screen by finger. - Do not perform maintenance on this unit yourself. Do not attempt to open the unit. In the event of a problem, contact your retailer. - Stop using the unit in the event of a failure or malfunction. - This electrical medical equipment requires special precautions regarding electromagnetic compatibility. It must be installed and used in accordance with electromagnetic information provided in the EMC Data table. - Readings may be distorted if the unit is used near a television, microwave oven, mobile phone or any other device with an electrical field.  3. PRODUCT INTENDED USE The Ear/forehead Infrared Thermometer is intended for human body temperature measuring for all ages, especially for infant, children and adult. Body temperature can be achieved from forehead or ear canal. It is intended to be used for family healthcare and hospital clinical reference.
    4 /  13  深圳理思科技有限公司 Visiomed Technology Co., Ltd.  4. INTRODUCTION It is imperative to use Pocket Thermometer appropriately to obtain a reliable and stable result. It is therefore advisable to read the instruction manual and safety instructions before use. It is suitable for the whole family.  Normal temperature by age.         Chamberlain, J.M., et al., Determination of Normal Ear. Temperature with an Infrared Emission Detection Thermometer, Annals of Emergency Medicine, January 1995. / Chamberlain, J.M., et al., Determination of Normal Ear. Temperature with an Infrared Emission Detection Thermometer, Annals of Emergency Medicine, enero de 1995./ Chamberlain, J.M., et al., Determination of Normal Ear. Temperature with an Infrared Emission Detection Thermometer, Annales de médecine d’urgence, janvier 1995.  Normal temperature according to procedure. Measurement method Normal T° Rectal   36.6  –  38°C Oral   37.5°C Axillary 34.7  –  37.3°C Aural 35.8  –  38°C Temporal/Forehead-Temple 35.8  –  37.8°C  Chamberlain, J.M., Terndrup, T.E., New Light on Ear Thermometer. Readings, Contemporary Pediatrics, March 1994. Chamberlain, J.M., et al., Determination of Normal Ear. Temperature with an Infrared Emission Detection Thermometer The temperature of the human body varies throughout the day. It can also be influenced by numerous external factors: age, sex, type and thickness of skin... / Chamberlain, J.M., Terndrup, T.E., New Light on Ear Thermometer. Readings, Contemporary Pediatrics, marzo de 1994. Chamberlain, J.M., et al., Determination of Normal Ear.    5. PRECAUTION BEFORE USE The Pocket Thermometer is pre-configured at the factory. It is not necessary to calibrate the device when it is first use.   To obtain reliable, stable results, please follow below instruction.  - Check the unit if there is any damage in appearance, check the LCD screen full display as below picture. Do not use the unit if any abnormality and contact your retailer. If battery capacity is low, follow the instruction to change a new battery.     AGE °C °F 0-2 36.4 - –8.0 97.5 - –00.4 3-10 36.1 - –7.8 97.0 - –00 11-65 35.9 - –7.6 96.6 - –9.7 > 65 35.8 - –7.5 96.4 - –9.5
    5 /  13  深圳理思科技有限公司 Visiomed Technology Co., Ltd.  - Before any new temperature measurement, wait for the screen to turn off.   - It is advisable, with each change of environment with a significant difference in ambient temperature, leave the MyThermo Pocket at this ambient temperature for at least 30 minutes before use. It is important to wait a period of 1 minute between measurements. If the person come from the different ambient temperature than the unit, please stay at least 5 minutes before taking temperature. - If there is sweat on forehead or use ice to cool the temperature may cause the measuring temperature lower than its real value, do not use the unit under this circumstance.  6. BODY TEMPERATURE The normal body temperature is located within a range, and a fixed value. Everyone has their own temperature range. When the body temperature rises or falls, the body initially regulates its temperature from the brain. Since the forehead and the ear are the body parts nearest the brain, they are the first to be informed of a temperature rise. Practical considerations when taking a temperature - In the interests of precision and measurement quality, it is essential that each user is adequately informed and trained in the temperature measurement technique when using such a device. - It is essential to remember that the procedure of taking a temperature although simple, should not be ignored. - The patient should not carry out strenuous activities before taking their temperature. - Temperature fluctuations due to physiological factors must be taken into consideration in the evaluation of the results: • The temperature increases by 0.5°C/0.9°F between 6:00 and 15:00, • The average temperature of women is about 0.2°C / 0.36°F and varies according to their ovarian cycle, • It increases by 0.5°C/0.9°F during the first half of the cycle and during the first months of pregnancy. • Age, sex, type and thickness of skin. - The temperature of a seated person is lower by around 0.3°C - –.4°C/0.54°F - –.52°F than that of a person standing.  Haut Conseil de Sante Publique [online]. Health Recommendations of the National Heatwave Plan 2014. P123 [Consulted on 25 July 2016] Available at http://social-sante.gouv.fr/IMG/pdf/ Recommendations_ sanitaires_Plan_canicule_2014. Pdf  7. SUGGESTIONS BEFORE MEASURING 1. Replace batteries that are too drained to effectively power the unit. 2. For a proper reading, condition the thermometer by placing it in the environment where the measurement will be taken 30 minutes before use. 3.  An  unexpected  fluctuation  of  the  ambient  temperature  may  distort  the  accuracy  of  the  reading.  For  example,  if  the temperature of the place where the measurement is taken is different from the temperature where the thermometer is stored, when one wants to take a temperature reading near an air conditioner. The results will be unreliable. 4. The measurement should be taken at rest, to yield accurate results. Body temperature is likely to increase just after exercise or after a bath. 5. Before taking a temperature, in order to obtain a stable, reliable result - Take care to brush away the hair. - Wipe any sweat from the brow. - Avoid air flows (e.g. supplemental oxygen, air conditioning, etc.). - Wait a period of 1 minute between measurements. - With each change of environment having a high ambient temperature difference, leave the thermometer at this ambient
    6 /  13  深圳理思科技有限公司 Visiomed Technology Co., Ltd. temperature for at least 30 min before use.  8. MENU SETTING & FUNCTIONS    8.1 MAIN FUNCTIONS 1. Display of the temperature reading in degrees Celsius or Fahrenheit: Temperature range from 30°C to 43°C (86°F to 109.4°F). 2. Memorization of the last 10 readings taken: The temperature is recorded. 3. Audible alarm during temperature measurement based on the result.  8.2 CHOICE OF TEMPERATURE UNIT   Open the battery cover, press the ℃/℉ button to select the temperature unit. The display shows ℃ to display degrees Celsius, ℉ to display degrees of Fahrenheit.   8.3 HOW TO MEASURE TEMPERATURE Insert the batteries. For the first use or when inserting new batteries, wait about 10 minutes to preheat the device. 1.For a forehead measurement 4. Picture A   (1) Before measuring, dry your forehead and fix the forehead temperature cap on the device. (2) Press the measurement button once to start the temperature reading and release it. The last measuring result will be displayed after  a  full-screen-display.  Aim the infrared probe  at the forehead, and the probe need touch skin gently, then press the measuring button for one second. The unit will beep once. It  indicates the measurement is completed. LCD Screen will display the measured temperature value, if the temperature exceeds the alarm temperature value, the buzzer will beep four times. (3) The infrared probe should be pointed to the centre of forehead (above the eyebrow) and kept vertical, the measured site cannot be covered by hair, and the device should be in contact with the forehead. (4) Holding the device in long time will make the detector read a higher ambient temperature, which may lead to an inaccurate measurement. (lower than actual temperature) (5) Keep static during the measuring.   (6) The measured site is showed on picture A.  2. For a tympanic temperature measurement Picture B  (1) Before measuring, take off the forehead temperature cap. Insert the tympanic probe along the ear canal. (2) Press the measuring button to start, the last measuring result will be displayed after a full-screen-display. Insert the tympanic probe along the ear canal, and then press the measuring button for one second. The unit will beep once. it indicates the measurement is completed, and the LCD screen will display the measured temperature value.   (3) If the temperature exceeds the alarm temperature value, the buzzer will beep four times.
    7 /  13  深圳理思科技有限公司 Visiomed Technology Co., Ltd. (4) Clean the ear canal before measuring. (5) In case of difficulty for inserting the probe, you can gently pull the ears backwards, insert gently along the ear canal, do not insert it strongly. (6) The measured site is showed on picture B.  Before any temperature measurements, take care to brush away the hair and clear any sweat from the forehead. The result is automatically stored. When taking consecutive temperature measurements, it is possible that the results will not be identical. Wait at least 1 minute between each measurement.  8.4 DATA MEMORY Open the battery compartment to access the setting buttons. Press the MEM button, the LCD screen reads and displays the last temperature reading. 1. --- will be displayed if no data is stored 2.  Press  the  MEM  button  to  scroll  through  the  previous  data,  then  press  the  °C/°F  to  scroll  through  the  next  data.  10 measurements are memorized.   Note: When changing batteries, the stored data will be erased.  9. BATTERY REPLACEMENT During the measurement, if the the screen with icon    flashing, it means the battery is drained;   When the unit is turned on, and then turns off immediately, that also means the battery is drained.  Remove the battery cover and use a tool to take out the old battery (below picture A), then place a new battery, taking care to respect the polarity. The LCD screen will display all the symbols on the screen. Use only new batteries (1 x CR2032), never use rechargeable batteries. Do not mix an old battery with a new battery. Replace the cover after inserting the battery (below picture B).               Insert a long and strong tool in the hole                                    IMPORTANT:   - Respect the polarity of the batteries. A polarity error can cause damage and void the warranty of your unit. - Do not use battery other than the battery mentioned, do not recharge non-rechargeable battery, do not incinerate them. - Remove the battery when not using the thermometer over a prolonged period. This may damage the product.  A B
    8 /  13  深圳理思科技有限公司 Visiomed Technology Co., Ltd. The symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office or your household waste disposal service.  10.  BLUETOOTH DATA TRANSMISSION - Press measurement button to wake up MyThermo Pocket. - Open the BewelleConnect APP in your mobile device, choose body temperature mode. MyThermo Pocket’s Bluetooth will connect with APP automatically. Bluetooth symbol will be displayed on the LCD screen of MyThermo Pocket. - Measuring data of body temperature will upload to APP automatically after Bluetooth connected well. - Diagnostic will be display on your device  Ear/forehead mode temperature To/℃ Display on LCD screen Warning indication Display on APP. To  <  30.0 Lo Di-Di-Di-Di Red 30.0  ≤  To  <  34.7 Measuring result Di-Di-Di-Di Red 34.7  ≤  To  ≤  37.3 Measuring result Di Green 37.3  <  To  ≤  38.0 Measuring result Di-Di-Di-Di Orange 38.0  < To ≤  43.0 Measuring result Di-Di-Di-Di Red To >  43.0 HI Di-Di-Di-Di Red  If you have trouble with the Bluetooth connection: - Check that you are in range of the Bluetooth accessory which you are trying to pair with MyThermo Pocket. - Make sure that your Bluetooth accessory is turned on and fully charged or connected to power.  11. UPKEEP, STORAGE AND CALIBRATION UPKEEP: 1. Remove any spots on the case with a soft, dry cloth. 2. Clean the probe tip as follows: wipe the surface very gently with a buffer, a soft cloth lightly moistened with 70% surgical spirit; you can use the thermometer once the alcohol has completely evaporated. 3. Do not immerse the unit in any liquid whatsoever. 4. When dirty, gently clean the IR sensor with a soft, dry cloth. Do not clean the infrared sensor with tissue or paper towel that may scratch it, which could lead to inaccurate results. 5. Do not touch the display screen when using alcohol to clean the device. 6. For stubborn stains, wipe the device with wrung cloth after dipping water or neutral solvent, then wipe the device with soft, dry cloth.   7. Do not use benzene, diluent, gasoline or other strong solvents to clean the device. 8. Do not use ultrasonic cleaning to clean the device. 9. For disinfection, please use a cotton swab or soft dry cloth with 70% alcohol dipped to wipe the device. 10. Do not use other chemical reagents to wipe the lens.
    9 /  13  深圳理思科技有限公司 Visiomed Technology Co., Ltd. 11. If you do not use the device for a long time, it is recommended to clean one time each month.  STORAGE: 1. Do not expose the thermometer to direct sunlight, extreme temperatures conditions (T° > 60°C or T° < -20°C), or under conditions of high humidity (above 95%), dust, near fire or high concentrations of salt in the air; do not subject it to inclinations, vibrations or direct impacts; Preservation of chemicals or the presence of corrosive gases. 2. Remove the batteries from the housing if you do not plan to use the unit over a long period.  CALIBRATION: This thermometer is pre-configured at the factory. If the operating instructions are followed, a re-calibration is not necessary. If you have doubts about the accuracy of temperature readings, please contact your retailer. Do not disassemble the thermometer yourself - this will void your warranty.  12. PRODUCT SPECIFICATION Product name Ear/forehead infrared thermometer Model NO. BW-MTX1 (connected BLE) Product size 76mm×50.6mm×25.5mm (L×W×H) Measuring range and accuracy 30℃~34.9℃:±0.3℃ 35.0℃~42℃:±0.2℃ 42.1℃~43℃:±0.3℃ Repeatability ≤±0.2℃ IR wavelength 5-14μm Emissivity 0.95 Automatic shutoff 15s Data storage 10 readings Displaying of reading ℃/℉ Display resolution 0.1℃ Internal time of each measurement >60s Battery CR2032×1 Voltage 2.5V~3.3V Dynamic current ≤15μA Quiescent current ≤25mA Consumption ≤90mW Product weight 38g
    10 /  13  深圳理思科技有限公司 Visiomed Technology Co., Ltd. Normal condition of use Temperature:15℃~40℃ Humidity:10%~85%RH Air pressure:70kPa~106kPa, non-condensing Storage conditions Temperature:-20℃~60℃ Humidity: ≤95%RH, Air pressure:50kPa~106kPa, non-condensing Water proof IP22 Warning temperature 37.3>0℃  <34.7℃ Alarm method Voice: Di-Di-Di-Di Back light: white LED Display format Black character in white background, LCD   Bluetooth version 4.0 BLE Bluetooth emission current ≤25Ma (for BW-MTX1) Frequency range 2402~2480MHz   MAX RF output power +4dBm Expected life time 5 years  13. TROUBLESHOOTING Problem Possible cause Solution The device does not switch on The batteries are discharged Put new batteries in the device The batteries are not properly installed Install the batteries properly, following the correct polarity Temperature  reading  hampered  by hair, sweat,...  Make sure there is no obstruction prior to taking the temperature. Temperature reading hampered by an air flow…  Be careful  not to be in the axis of  an airflow,  this  could  cause  interference with the infrared system. The  display  indicates  temperatures above 95°: The  temperature  is  indicated  in Fahrenheit. Change the unit of measure to Celsius. The screen displa Er1 Ambiant  temperature  is  lower  than 15°C  The screen display Er2 Ambiant  temperature  is  higher  than 40°C
    11 /  13  深圳理思科技有限公司 Visiomed Technology Co., Ltd. 14. EMC data
    12 /  13  深圳理思科技有限公司 Visiomed Technology Co., Ltd.   15. FCC compliance   This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Caution: changes or modifications not  expressly approved by the  party responsible for compliance  could void the user’s
    13 /  13  深圳理思科技有限公司 Visiomed Technology Co., Ltd. authority to operate the equipment. NOTE: this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection  against  harmful  interference  in  a  residential installation.  This  equipment  generates,  uses  and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.  16. WARRANTY Visiomed  will  repair  or  replace  this  product  free  of  charge  in  the  case  of  defective  parts  or  manufacturing  defects,  in accordance with the conditions mentioned below as follows: DURATION: 24 MONTHS RETURN TO WORKSHOP LIMITS AND EXCLUSIONS: This guarantee concerns only the original final purchaser. A purchase invoice, or another proof of purchase, with this guarantee card will be required to obtain an after-sales service, in accordance with this guarantee. This guarantee card will not be extended to another person only the original final purchaser. This guarantee becomes void if the serial numbers on the product are modified, replaced, illegible, absent, or if repair has been carried out by a service not approved, including the user. This guarantee covers only the defects of the material or parts, occurring during normal use of the pro-duct. It does not cover the damage caused during the transport of the apparatus, causes due to repairs being carried out by the distributor, by any modifications undertaken, any connection of equipment not approved by Visiomed, or causes contrary to those written in the user manual or notice. Moreover, the present guarantee does not cover damage due to falls, bad handling, bad installations, damage by fire, floods, lightning, or any other natural disaster. This guarantee does not cover the packing of the material, the accessories, the defects caused by commercial exposure of the product, show room, sale space, demonstration etc... Normal maintenance, cleaning and the replacement of parts where wear is normal, are not covered by the terms of this guarantee.  Visiomed  and  its  representatives  and  agents  will  not  in  any  case  be  held  responsible  for  any  damage  and consecutive damages due to the mishandling of this product. This guarantee is the only valid one at Visiomed, any other guarantee (commercial guarantee) except this one will not be taken into account. IMPORTANT: During the guarantee period if you are dissatisfied with the repairs of this product, please contact the Visiomed customer service.