EAR/FOREHEAD INFRARED THERMOMETER
BW-MTX1
2 / 13
深圳理思科技有限公司
Visiomed Technology Co., Ltd.
THE MANUFACTURER RESERVES THE RIGHT TO MODIFY THE PRODUCT TECHNICAL SPECIFICATIONS WITHOUT PRIOR NOTICE.
Find out how to install and use the BewellConnect APP by visiting our website at
https://bewell-connect.com/en/applications-support/
Dear Customer,
Thank you for purchasing MyThermo Pocket Infrared Ear/Forehead Thermometer BW-MTX1, by Visiomed. We
hope that you enjoy using it and recommend reading this user guide carefully.
1. PRODUCT DESCRIPTION
2. SAFETY INSTRUCTION
It is important to read all the warnings and precautions in this manual. They are for your safety, to prevent injuries and
avoid situations that could damage the device.
Consult your doctor, if you have a serious illness or if you want to know more about using this medical device.
2.1 Warning
- Do not use the unit to measure temperature near the air outlet of air fan or air condition.
- Do not use the unit out door or in strong sunshine.
- It is recommended to take 3 measurement each time, subject to the data displayed most.
- The unit will shut down automatically in 15s after measurement finished if no other operation.
- Do not leave this unit within the reach of children. A self-measurement taken forcibly by children can damage their ear. In
the event of accidental ingestion of the battery or the protective film, see a physician immediately.
Item
Measurement button
IR Probe
Forehead temperature cap
Window of the probe
LCD display
Battery
Battery compartment
/ button
MEM button
Battery cover
3 / 13
深圳理思科技有限公司
Visiomed Technology Co., Ltd.
- The measurement results are for informational purposes only. If unsure about your results, please contact your physician.
- Do not use the unit if the probe is damaged.
- This product should not encourage you to self-medicate or adapt your treatment
- Stop using the unit if any pain occurs. There is a risk of damaging the ear canal.
- It is not recommended to use the device on patients with ear diseases such as otitis externa and tympanitis.
- Do not use the unit in a wet ear canal, such as after swimming or after a bath. There is a risk of damaging the ear canal.
- Do not touch or blow on the infrared sensor. A dirty or damaged infrared sensor may cause inaccurate results.
2.2 Caution
Constraints before taking the temperature:
- For a forehead temperature reading (centre forehead), take care to brush away the hair, wipe any sweat off the
brow, avoid air flows, (e.g. supplemental oxygen, air conditioning, etc.).
- To measure the tympanic temperature, make sure that the ear canal is clean, as an ear with excess wax can give inaccurate
readings.
- If there is sweat on forehead or use ice to cool the temperature may cause the measuring temperature lower than its real
value, do not use the unit under this circumstance.
Please contact your doctor when the unit is warning after measuring. High fever or fever in long time should go to hospital,
especially for infants and children.
2.3 General precautions
- Use this unit only for its intended purpose as described in this manual.
- Follow the maintenance instructions specified in this manual.
- This device is designed for external use.
- Use and storage: Refer to the technical features (range of room temperature, relative humidity, atmospheric pressure).
- This unit should always be stored in a clean, dry place.
- Do not expose this unit to sunlight or water.
- Do not use this unit outdoors.
- Do not expose this unit to electrical shocks.
- Never drop this unit.
- Do not touch the screen by finger.
- Do not perform maintenance on this unit yourself. Do not attempt to open the unit. In the event of a problem, contact your
retailer.
- Stop using the unit in the event of a failure or malfunction.
- This electrical medical equipment requires special precautions regarding electromagnetic compatibility. It must be installed
and used in accordance with electromagnetic information provided in the EMC Data table.
- Readings may be distorted if the unit is used near a television, microwave oven, mobile phone or any other device with an
electrical field.
3. PRODUCT INTENDED USE
The Ear/forehead Infrared Thermometer is intended for human body temperature measuring for all ages, especially for
infant, children and adult. Body temperature can be achieved from forehead or ear canal. It is intended to be used for
family healthcare and hospital clinical reference.
4 / 13
深圳理思科技有限公司
Visiomed Technology Co., Ltd.
4. INTRODUCTION
It is imperative to use Pocket Thermometer appropriately to obtain a reliable and stable result. It is therefore advisable to read
the instruction manual and safety instructions before use.
It is suitable for the whole family.
Normal temperature by age.
Chamberlain, J.M., et al., Determination of Normal Ear. Temperature with an Infrared Emission Detection Thermometer, Annals of
Emergency Medicine, January 1995. / Chamberlain, J.M., et al., Determination of Normal Ear. Temperature with an Infrared
Emission Detection Thermometer, Annals of Emergency Medicine, enero de 1995./ Chamberlain, J.M., et al., Determination of
Normal Ear. Temperature with an Infrared Emission Detection Thermometer, Annales de médecine d’urgence, janvier 1995.
Normal temperature according to procedure.
Measurement method
Normal T°
Rectal
36.6 38°C
Oral
37.5°C
Axillary
34.7 37.3°C
Aural
35.8 38°C
Temporal/Forehead-Temple
35.8 37.8°C
Chamberlain, J.M., Terndrup, T.E., New Light on Ear Thermometer. Readings, Contemporary Pediatrics, March 1994. Chamberlain,
J.M., et al., Determination of Normal Ear. Temperature with an Infrared Emission Detection Thermometer The temperature of the
human body varies throughout the day. It can also be influenced by numerous external factors: age, sex, type and thickness of
skin... / Chamberlain, J.M., Terndrup, T.E., New Light on Ear Thermometer. Readings, Contemporary Pediatrics, marzo de 1994.
Chamberlain, J.M., et al., Determination of Normal Ear.
5. PRECAUTION BEFORE USE
The Pocket Thermometer is pre-configured at the factory. It is not necessary to calibrate the device when it is first use.
To obtain reliable, stable results, please follow below instruction.
- Check the unit if there is any damage in appearance, check the LCD screen full display as below picture. Do not use
the unit if any abnormality and contact your retailer. If battery capacity is low, follow the instruction to change a new
battery.
AGE
°F
0-2
97.5 - –00.4
3-10
97.0 - –00
11-65
96.6 - –9.7
> 65
96.4 - –9.5
5 / 13
深圳理思科技有限公司
Visiomed Technology Co., Ltd.
- Before any new temperature measurement, wait for the screen to turn off.
- It is advisable, with each change of environment with a significant difference in ambient temperature, leave the
MyThermo Pocket at this ambient temperature for at least 30 minutes before use. It is important to wait a period of 1
minute between measurements. If the person come from the different ambient temperature than the unit, please stay
at least 5 minutes before taking temperature.
- If there is sweat on forehead or use ice to cool the temperature may cause the measuring temperature lower than
its real value, do not use the unit under this circumstance.
6. BODY TEMPERATURE
The normal body temperature is located within a range, and a fixed value. Everyone has their own temperature range. When
the body temperature rises or falls, the body initially regulates its temperature from the brain. Since the forehead and the ear
are the body parts nearest the brain, they are the first to be informed of a temperature rise.
Practical considerations when taking a temperature
- In the interests of precision and measurement quality, it is essential that each user is adequately informed and trained in the
temperature measurement technique when using such a device.
- It is essential to remember that the procedure of taking a temperature although simple, should not be ignored.
- The patient should not carry out strenuous activities before taking their temperature.
- Temperature fluctuations due to physiological factors must be taken into consideration in the evaluation of the results:
• The temperature increases by 0.5°C/0.9°F between 6:00 and 15:00,
• The average temperature of women is about 0.2°C / 0.36°F and varies according to their ovarian cycle,
• It increases by 0.5°C/0.9°F during the first half of the cycle and during the first months of pregnancy.
• Age, sex, type and thickness of skin.
- The temperature of a seated person is lower by around 0.3°C - –.4°C/0.54°F - –.52°F than that of a person standing.
Haut Conseil de Sante Publique [online]. Health Recommendations of the National Heatwave Plan 2014. P123 [Consulted on 25 July
2016] Available at http://social-sante.gouv.fr/IMG/pdf/ Recommendations_ sanitaires_Plan_canicule_2014. Pdf
7. SUGGESTIONS BEFORE MEASURING
1. Replace batteries that are too drained to effectively power the unit.
2. For a proper reading, condition the thermometer by placing it in the environment where the measurement will be taken 30
minutes before use.
3. An unexpected fluctuation of the ambient temperature may distort the accuracy of the reading. For example, if the
temperature of the place where the measurement is taken is different from the temperature where the thermometer is stored,
when one wants to take a temperature reading near an air conditioner. The results will be unreliable.
4. The measurement should be taken at rest, to yield accurate results.
Body temperature is likely to increase just after exercise or after a bath.
5. Before taking a temperature, in order to obtain a stable, reliable result
- Take care to brush away the hair.
- Wipe any sweat from the brow.
- Avoid air flows (e.g. supplemental oxygen, air conditioning, etc.).
- Wait a period of 1 minute between measurements.
- With each change of environment having a high ambient temperature difference, leave the thermometer at this ambient
6 / 13
深圳理思科技有限公司
Visiomed Technology Co., Ltd.
temperature for at least 30 min before use.
8. MENU SETTING & FUNCTIONS
8.1 MAIN FUNCTIONS
1. Display of the temperature reading in degrees Celsius or Fahrenheit: Temperature range from 30°C to 43°C (86°F to 109.4°F).
2. Memorization of the last 10 readings taken: The temperature is recorded.
3. Audible alarm during temperature measurement based on the result.
8.2 CHOICE OF TEMPERATURE UNIT
Open the battery cover, press the / button to select the temperature unit. The display shows to display degrees Celsius,
to display degrees of Fahrenheit.
8.3 HOW TO MEASURE TEMPERATURE
Insert the batteries. For the first use or when inserting new batteries, wait about 10 minutes to preheat the device.
1.For a forehead measurement
4. Picture A
1 Before measuring, dry your forehead and fix the forehead temperature cap on the device.
2 Press the measurement button once to start the temperature reading and release it. The
last measuring result will be displayed after a full-screen-display. Aim the infrared probe at the
forehead, and the probe need touch skin gently, then press the measuring button for one second.
The unit will beep once. It indicates the measurement is completed. LCD Screen will display the
measured temperature value, if the temperature exceeds the alarm temperature value, the buzzer
will beep four times.
3 The infrared probe should be pointed to the centre of forehead (above the eyebrow) and kept vertical, the
measured site cannot be covered by hair, and the device should be in contact with the forehead.
4 Holding the device in long time will make the detector read a higher ambient temperature, which may lead to
an inaccurate measurement. (lower than actual temperature)
5 Keep static during the measuring.
6 The measured site is showed on picture A.
2. For a tympanic temperature measurement
Picture B
1 Before measuring, take off the forehead temperature cap. Insert the tympanic probe along
the ear canal.
2 Press the measuring button to start, the last measuring result will be displayed after a full-
screen-display. Insert the tympanic probe along the ear canal, and then press the measuring button
for one second. The unit will beep once. it indicates the measurement is completed, and the LCD
screen will display the measured temperature value.
3 If the temperature exceeds the alarm temperature value, the buzzer will beep four times.
7 / 13
深圳理思科技有限公司
Visiomed Technology Co., Ltd.
4 Clean the ear canal before measuring.
5 In case of difficulty for inserting the probe, you can gently pull the ears backwards, insert gently along the ear
canal, do not insert it strongly.
6 The measured site is showed on picture B.
Before any temperature measurements, take care to brush away the hair and clear any sweat from the forehead.
The result is automatically stored. When taking consecutive temperature measurements, it is possible that the results will not
be identical. Wait at least 1 minute between each measurement.
8.4 DATA MEMORY
Open the battery compartment to access the setting buttons. Press the MEM button, the LCD screen reads and displays the
last temperature reading.
1. --- will be displayed if no data is stored
2. Press the MEM button to scroll through the previous data, then press the °C/°F to scroll through the next data. 10
measurements are memorized.
Note: When changing batteries, the stored data will be erased.
9. BATTERY REPLACEMENT
During the measurement, if the the screen with icon flashing, it means the battery is drained;
When the unit is turned on, and then turns off immediately, that also means the battery is drained.
Remove the battery cover and use a tool to take out the old battery (below picture A), then place a new battery, taking care
to respect the polarity.
The LCD screen will display all the symbols on the screen.
Use only new batteries (1 x CR2032), never use rechargeable batteries. Do not mix an old battery with a new battery.
Replace the cover after inserting the battery (below picture B).
Insert a long and strong tool in the hole
IMPORTANT:
- Respect the polarity of the batteries. A polarity error can cause damage and void the warranty of your unit.
- Do not use battery other than the battery mentioned, do not recharge non-rechargeable battery, do not incinerate
them.
- Remove the battery when not using the thermometer over a prolonged period. This may damage the product.
A
B
8 / 13
深圳理思科技有限公司
Visiomed Technology Co., Ltd.
The symbol on the product or on its packaging indicates that this product must not be disposed of with your other household
waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point
for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment
at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human
health and the environment. For more information about where you can drop off your waste equipment for recycling, please
contact your local city office or your household waste disposal service.
10. BLUETOOTH DATA TRANSMISSION
- Press measurement button to wake up MyThermo Pocket.
- Open the BewelleConnect APP in your mobile device, choose body temperature mode. MyThermo Pockets Bluetooth will
connect with APP automatically. Bluetooth symbol will be displayed on the LCD screen of MyThermo Pocket.
- Measuring data of body temperature will upload to APP automatically after Bluetooth connected well.
- Diagnostic will be display on your device
Ear/forehead mode temperature
To/
Display on LCD
screen
Warning
indication
Display on APP.
To 30.0
Lo
Di-Di-Di-Di
Red
30.0 To 34.7
Measuring result
Di-Di-Di-Di
Red
34.7 To 37.3
Measuring result
Di
Green
37.3 To 38.0
Measuring result
Di-Di-Di-Di
Orange
38.0 To 43.0
Measuring result
Di-Di-Di-Di
Red
To 43.0
HI
Di-Di-Di-Di
Red
If you have trouble with the Bluetooth connection:
- Check that you are in range of the Bluetooth accessory which you are trying to pair with MyThermo Pocket.
- Make sure that your Bluetooth accessory is turned on and fully charged or connected to power.
11. UPKEEP, STORAGE AND CALIBRATION
UPKEEP:
1. Remove any spots on the case with a soft, dry cloth.
2. Clean the probe tip as follows: wipe the surface very gently with a buffer, a soft cloth lightly moistened with 70% surgical
spirit; you can use the thermometer once the alcohol has completely evaporated.
3. Do not immerse the unit in any liquid whatsoever.
4. When dirty, gently clean the IR sensor with a soft, dry cloth.
Do not clean the infrared sensor with tissue or paper towel that may scratch it, which could lead to inaccurate results.
5. Do not touch the display screen when using alcohol to clean the device.
6. For stubborn stains, wipe the device with wrung cloth after dipping water or neutral solvent, then wipe the device with soft,
dry cloth.
7. Do not use benzene, diluent, gasoline or other strong solvents to clean the device.
8. Do not use ultrasonic cleaning to clean the device.
9. For disinfection, please use a cotton swab or soft dry cloth with 70% alcohol dipped to wipe the device.
10. Do not use other chemical reagents to wipe the lens.
9 / 13
深圳理思科技有限公司
Visiomed Technology Co., Ltd.
11. If you do not use the device for a long time, it is recommended to clean one time each month.
STORAGE:
1. Do not expose the thermometer to direct sunlight, extreme temperatures conditions (T° > 60°C or < -20°C), or under
conditions of high humidity (above 95%), dust, near fire or high concentrations of salt in the air; do not subject it to inclinations,
vibrations or direct impacts; Preservation of chemicals or the presence of corrosive gases.
2. Remove the batteries from the housing if you do not plan to use the unit over a long period.
CALIBRATION:
This thermometer is pre-configured at the factory. If the operating instructions are followed, a re-calibration is not necessary.
If you have doubts about the accuracy of temperature readings, please contact your retailer.
Do not disassemble the thermometer yourself - this will void your warranty.
12. PRODUCT SPECIFICATION
Product name
Ear/forehead infrared thermometer
Model NO.
BW-MTX1 (connected BLE)
Product size
76mm×50.6mm×25.5mm (L×W×H)
Measuring range and accuracy
30~34.9±0.3
35.0~42±0.2
42.1~43±0.3
Repeatability
≤±0.2
IR wavelength
5-14μm
Emissivity
0.95
Automatic shutoff
15s
Data storage
10 readings
Displaying of reading
/
Display resolution
0.1
Internal time of each measurement
>60s
Battery
CR2032×1
Voltage
2.5V~3.3V
Dynamic current
≤15μA
Quiescent current
25mA
Consumption
90mW
Product weight
38g
10 / 13
深圳理思科技有限公司
Visiomed Technology Co., Ltd.
Normal condition of use
Temperature:15~40
Humidity:10%~85%RH
Air pressure:70kPa106kPa, non-condensing
Storage conditions
Temperature:-20~60
Humidity: ≤95%RH,
Air pressure:50kPa106kPa, non-condensing
Water proof
IP22
Warning temperature
37.3>0
<34.7
Alarm method
Voice: Di-Di-Di-Di
Back light: white LED
Display format
Black character in white background, LCD
Bluetooth version
4.0 BLE
Bluetooth emission current
≤25Ma (for BW-MTX1)
Frequency range
2402~2480MHz
MAX RF output power
+4dBm
Expected life time
5 years
13. TROUBLESHOOTING
Problem
Possible cause
Solution
The device does not switch on
The batteries are discharged
Put new batteries in the device
The batteries are not properly installed
Install the batteries properly, following
the correct polarity
Temperature reading hampered by
hair, sweat,...
Make sure there is no obstruction prior
to taking the temperature.
Temperature reading hampered by an
air flow…
Be careful not to be in the axis of an
airflow, this could cause interference
with the infrared system.
The display indicates temperatures
above 95°:
The temperature is indicated in
Fahrenheit.
Change the unit of measure to Celsius.
The screen displa Er1
Ambiant temperature is lower than
15°C
The screen display Er2
Ambiant temperature is higher than
40°C
11 / 13
深圳理思科技有限公司
Visiomed Technology Co., Ltd.
14. EMC data
12 / 13
深圳理思科技有限公司
Visiomed Technology Co., Ltd.
15. FCC compliance
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
Caution: changes or modifications not expressly approved by the party responsible for compliance could void the users
13 / 13
深圳理思科技有限公司
Visiomed Technology Co., Ltd.
authority to operate the equipment.
NOTE: this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
16. WARRANTY
Visiomed will repair or replace this product free of charge in the case of defective parts or manufacturing defects, in
accordance with the conditions mentioned below as follows:
DURATION: 24 MONTHS RETURN TO WORKSHOP
LIMITS AND EXCLUSIONS: This guarantee concerns only the original final purchaser. A purchase invoice, or another proof of
purchase, with this guarantee card will be required to obtain an after-sales service, in accordance with this guarantee. This
guarantee card will not be extended to another person only the original final purchaser. This guarantee becomes void if the
serial numbers on the product are modified, replaced, illegible, absent, or if repair has been carried out by a service not
approved, including the user. This guarantee covers only the defects of the material or parts, occurring during normal use of
the pro-duct. It does not cover the damage caused during the transport of the apparatus, causes due to repairs being carried
out by the distributor, by any modifications undertaken, any connection of equipment not approved by Visiomed, or causes
contrary to those written in the user manual or notice. Moreover, the present guarantee does not cover damage due to falls,
bad handling, bad installations, damage by fire, floods, lightning, or any other natural disaster. This guarantee does not cover
the packing of the material, the accessories, the defects caused by commercial exposure of the product, show room, sale
space, demonstration etc...
Normal maintenance, cleaning and the replacement of parts where wear is normal, are not covered by the terms of this
guarantee. Visiomed and its representatives and agents will not in any case be held responsible for any damage and
consecutive damages due to the mishandling of this product.
This guarantee is the only valid one at Visiomed, any other guarantee (commercial guarantee) except this one will not be taken
into account.
IMPORTANT: During the guarantee period if you are dissatisfied with the repairs of this product, please contact the Visiomed
customer service.