Visiomed Technology VMT-BPT1B Blood Pressure Monitor User Manual

Visiomed Technology Co., Ltd. Blood Pressure Monitor

Users Manual

                                                                                    1. Armband 2. Socket 3. Cuff tubing connector 4. Connection tube 5. CPU   TABLE OF CONTENTS 1. NOTES ON SAFETY 1.1. WARNING 1.2. CAUTION 1.3. GENERAL PRECAUTION 1.4. CYBERSECURITY INFORMATIONS AND RECOMMENDATIONS 2. INFORMATION 3. FEATURES 4. USE 4.1. DESCRIPTION 4.2. DOWNLOAD APPLICATION 4.3. INDICATIONS FOR SELF-MEASUREMENT 4.4. CONTRAINDICATIONS FOR SELF-MEASUREMENT 4.5. PRECAUTIONS BEFORE USE 4.6. SUGGESTIONS BEFORE MEASUREMENT 4.7. INSTRUCTIONS   4.8. USER GUIDE 5. INSERT OR REPLACE BATTERIES 6. HOW TO MAINTAIN AND STORE THE UNIT 7. HOW TO PREVENT A MALFUNCTION 8. SPECIFICATIONS 9. TROUBLESHOOTING 10. EMC DECLARATION 11. FCC COMPLIANCE 12. CALIBRATION AND SERVICE 13. WARRANTY INFORMATION
                                                              THIS PRODUCT COMPLIES WITH IEC 60601-1:2005+A1:2012; IEC 60601-1-11:2015; IEC 80601-2-30: 2009/AMD1:2013; IEC 60601-1-2:2014.  WE,  VISIOMED,  HEREBY  DECLARES  UNDER  OUR  SOLE  RESPONSIBILITY THAT  THE  FOLLOWING  PRODUCT  VMT-BPT1B  MYTENSIO  IS  IN COMPLIANCE  WITH  THE  ESSENTIAL  REQUIREMENTS  AND  OTHER RELEAVANT  PROVISIONS  OF  THE  RED  2014/53/EU  DIRECTIVE.  THIS CONFORMITY DECLARATION CAN BE FOUND ON OUR WEBSITE AT: https://bewell-connect.com/en/conformite-produits-bewellconnect/   Dear Customer, Thank you for purchasing MyTensio VMT-BPT1B 濹瀅瀂瀀澳濩濼瀆濼瀂瀀濸濷瀻濁澳濜瀁澳瀂瀅濷濸瀅澳to  use  it  optimally  and  efficiently,  we  recommend  that  you  read  the operating instructions carefully.   濟瀂濺澳瀂瀁瀇瀂澳瀂瀈瀅澳瀊濸濵瀆濼瀇濸澳瀇瀂澳濹濼瀁濷澳瀂瀈瀇澳濻瀂瀊澳瀇瀂澳濼瀁瀆瀇濴濿濿澳濴瀁濷澳瀈瀆濸澳瀇濻濸澳濕濸瀊濸濿濿濖瀂瀁瀁濸濶瀇瀻澳application https://bewell-connect.com/en/applications-support/   The manufacturer keeps the right to modify without any preliminary opinion technical specifications of the product.   1. NOTES ON SAFETY It is important to read all the warnings and precautions in this manual. They are  for  your  safety,  to  prevent  injuries  and  avoid  situations  that  could damage the device. Consult your doctor, if you have a serious illness or if you want to know more about using this medical device.  1.1. WARNING - This product should not encourage you to self-medicate or adapt your treatment. - Too frequent measurements can cause injury to the patient due to blood flow interference. -  Do  not  curve  the  tube  during  measuring,  the  curved  tube  may  block deflation and lead to injury. - Do not measure on an injured arm, thus could cause further injury. - Stop measurement immediately, if an allergic reaction occurs.  1.2. CAUTION - Do not inflate the upper arm cuff when it is not wrapped on the upper arm. -  Do  not  use  force  to  bend  or  pull  the  cuff.  Always  use  the  specified accessories in the manual, the use of other parts not approved by the manufacturer may cause hazard. - Do not use accessories that are not specified on this user manual. - Do not change the detachable components by yourself. - Do not compress or restrict the connection tubing, in case of damage.
                                                              1.3. GENERAL PRECAUTION - Use this device only for the use for which it is designed as described in this manual. - This device may be used for personal use at home. Do not use the unit for other purposes. - This device is designed for external use. -  Use  and  storage:  Refer  to  the  technical  features  (range  of  room temperature, relative humidity, atmospheric pressure, altitude) - This device must always be placed in a clean and dry place. - Do not expose this device to sunlight or water. - Do not expose this device to electric shocks. - Do not use this device outdoors. - Never drop the device. - Follow the maintenance instructions specified in this manual. - Do not attempt to open the device. In case of problems, contact customer service. - Do not leave this device within the reach of children. - This appliance is not designed for use by people (including children) with reduced physical, emotional or mental abilities or those lacking experience or knowledge unless used in the presence of someone responsible for their security, under supervision or following instructions about how to use the appliance. - Discontinue use of the device in case of anomalies or malfunction. - Stop using the unit in the event of a failure or malfunction. - This electrical medical equipment requires specific precautions regarding electromagnetic compatibility. It  must be installed and used  according to the electromagnetic information. - The equipment is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the  equipment  can  help  prevent  electromagnetic  interference  by maintaining  a  minimum  distance  between  portable  and  mobile  RF communications  equipment  (transmitters)  and  the  equipment  as recommended at the end of the manual, according to the maximum output power of the communications equipment. - Readings may be distorted if the unit is used near a television, microwave oven, mobile phone or any other device with an electrical field.  1.4. CYBERSECURITY INFORMATIONS AND RECOMMENDATIONS  To get the mobile application to work properly, be sure to get a reliable and secure network connection.  For  the  correct  functioning  of  the  app,  a  Bluetooth  connection  is necessary.  Personal  data  are  stored  in  a  Healthcare  data  host  (with  network connection)  located  in  France.  For  the  security  of  your  data,  do  not share  your  smartphone/tablet  with  your  app  logged  in.  Data  are transferred  from  your  device  to  the  Healthcare  data  host  under  a secured protocol.  The MyTensio app is compatible with the following operating systems: Android 4.3 or higher iOS 8.0 or higher  Check regularly if the APP has been updated on the stores. Proceed to
                                                              any  product  update  when  applicable.  Theses  updates  may  concern security improvement.  2. INFORMATION Blood pressure varies considerably throughout the day, and these variations are even more significant in hypertensive subjects. It is lower in the morning and increases in the afternoon and the evening. When sleeping, it decreases. Blood pressure is lower in summer than in winter, and it rises noticeably with age. Blood pressure also increases during exercise, sex, pregnancy, stress, etc.  Note: One or two blood pressure readings will not provide a true indication of your blood pressure, it is important to measure it daily and regularly to obtain accurate data. Sharing your results with your physician,  may  help  him/her  diagnose  you  and  prevent  potential  health problems. BLOOD  PRESSURE  CATEGORIES  IN  UNITED  STATES.  (2017  ACC/AHA GUIDELINES)  When systolic and diastolic pressure fall into different categories, the higher pressure determines color code.  Self-measurement of blood pressure - MAM (Measurement average mode): MAM technology makes it possible to  automatically  perform  three  repeated  measurements  in  moments. Repetition  is  essential  when  measuring  blood  pressure  oneself,  because isolated  readings  are  often  wrong  for  many  reasons,  including  the  high variability of blood pressure, and high susceptibility to outside factors such as  recent  activity  or  stress.  Taking  3  consecutive  readings  and  averaging them can improve the reliability of blood pressure measurement at home by a non-professional. This mode of use is especially recommended by the SFHTA in case of self-measurement. 濕濿濴濶濻濸瀅澿澳 濝濁澿澳 濸瀇澳 濴濿濁澳 澵濣瀅濼瀆濸澳 濸瀁澳 濶濻濴瀅濺濸澳 濷濸澳 濿瀠濻瀌瀃濸瀅瀇濸瀁瀆濼瀂瀁澳 濴瀅瀇灶瀅濼濸濿濿濸澳 濷濸澳 濿瀠濴濷瀈濿瀇濸濁澳
                                                              濥濸濶瀂瀀瀀濴瀁濷濴瀇濼瀂瀁瀆澳濅濃濄濆澳濷濸澳濿濴澳濦瀂濶濼灶瀇灶澳濹瀅濴瀁灴濴濼瀆濸澳濷瀠濻瀌瀃濸瀅瀇濸瀁瀆濼瀂瀁澳濴瀅瀇灶瀅濼濸濿濿濸濁澵 Annales de 濖濴瀅濷濼瀂濿瀂濺濼濸澳濸瀇澳濷澺濔瀁濺灶濼瀂濿瀂濺濼濸濁澳濩瀂濿濁澳濉濅濁澳濡瀂濁澳濆濁澳濘濿瀆濸瀉濼濸瀅澳濠濴瀆瀆瀂瀁澿澳濅濃濄濆濁  - Rule of 3s: 3 readings recommended while sitting, resting, 3 days in a row: in the morning beforetaking medications, 3 consecutive readings (MAM); in the evening after taking medications, 3 readings in a row (MAM). A single reading is not necessarily significant, especially in terms of monitoring your blood pressure. - Self-measurement of blood pressure: The monitoring targets for a known hypertensive subject  using  self-measurement  at  home  are different  from those of the European Society of Hypertension (ESH, which establishes the classification of the blood pressure) and lower. These targets are based on age and may vary depending on your condition General case: SBP***< 135 mmHg and DBP**** < 85 mmHg Age > 80 years: SBP* < 150 mmHg Chronic renal failure: SBP*** < 130 mmHg and DBP**** < 80 mmHg The  figures  above  are  for  general,  informational  purposes  only  and  they must be re-validated in each case with a physician. It is important to check your targets, especially in cases of serious illness or pregnancy.  * Millimeter of mercury **Contact your doctor immediately ***Systolic Blood Pressure ****Diastolic Blood Pressure  3. FEATURES - Oscillometric method - Pressure sensor inserted in silicon - Automatic blood pressure and heart rate measurement - Cuff size: 22-42cm (8.6-16.5in) (suitable for arm width between 22 and 42cm (8,6-16,5in) - 2 modes of measurement: MAM (Measurement Average Mode) - Heart arrhythmia detection - Automatic switch-off - Data transfer to Bluetooth 4.0 compatible smartphones/tablets.  4. USE 4.1. DESCRIPTION View diagram B page 2 Intended use The arm sphygmonameter is used to measure blood pressure and heart rate from the upper arm using the oscillometric method. The device is intended for  use  in  only  adult  population  at  home  care  or  hospital  facilities,  not applied to other populations such as neonatal baby. Operating principle This digital blood pressure monitor uses the oscillometric method of blood pressure  measurement  which  means  that  the  monitor  detects  the  signal through your brachial artery and converts it into a digital reading.
                                                               4.2 DOWNLOAD APPLICATION  - The following information is subject to change. Download the BewellConnect APP on your mobile phone or tablet. - APP store or Google Play. Then click on the MyTensio icon.      4.3. INDICATIONS FOR SELF-MEASUREMENT Self-measurement of blood pressure is recommended for: - Patients starting antihypertensive treatment to determine its effectiveness. -  Patients  requiring  closer  monitoring  regarding  their  in  between consultations (patients with coronary heart disease, diabetes and / or renal disease). - Pregnant women looking to prevent preeclampsia. - Patients with cardiovascular risk. - People displaying 濻濼濺濻澳濵濿瀂瀂濷澳瀃瀅濸瀆瀆瀈瀅濸澳濴瀇澳濷瀂濶瀇瀂瀅瀠瀆澳瀉濼瀆濼瀇瀆澳- to eliminate a white coat effect or confirm a real case of hypertension. - Elderly patients whose blood pressure variability is increased, and whose frequency of white coat effect gradually increases with age. - People suspected to mask hypertension (not detected at the doctor). - In case of resistant hypertension. - Servicing and maintenance are not allowed during device use. -  Pressurization  of  the  CUFF  can  temporarily  cause  loss  of  function  of simultaneously used monitoring medical electrical equipment on the same limb.  4.4. CONTRADICATIONS FOR SELF-MEASUREMENT Self-measurement of blood pressure is contraindicated on: - People under 18 years. - Patients suffering from: Atrial  fibrillation  or  other  serious  heart  condition  such  as  a  serious  heart arrhythmia; Anxious or obsessional disorders; Elderly cognitive impairment (unless used by a third party); Physical disability, Handicap -  An  arm  wearing  a  dialysis  fistula,  peripheral  venous  catheter:  to  avoid impaired functioning of the fistula or the catheter, the formation of blood clots in the vein, - An arm having undergone axillary lymphadenectomy. The increase of the pressure in nearby blood vessels can lead to the swelling of the arms and hands (lymphedema). - A Hemiplegic arm. -  Obesity:  Body  Mass  Index  (BMI)  >  30  (arm  band  unsuitable),  arm perimeter > 42cm (16,5in). - Application of the CUFF and its pressurization on the arm on the side of a mastectomy.  4.5. PRECAUTIONS BEFORE USE -  Do  not  confuse  self-monitoring  with  self-diagnosis.  Blood  pressure measurements should only be interpreted by a health professional who is familiar with your medical history. - If you are taking medication, consult with your physician to determine the
                                                              most appropriate time to measure your blood pressure. NEVER change a prescribed medication without first consulting with your physician. - This device is designed for adults to use. if this device is used on a child patient, the elderly or toddlers, consult with your physician. - This product should not encourage self-medication or adaptation of your treatment. -  If  there  is  too  much  pressure  or  you  feel  uncomfortable,  please  press ON/START button immediately for quick deflation. -  Do  not  use  this  unit  in  a  moving  vehicle;  this  may  result  in  erroneous measurement.  4.6. SUGGESTIONS BEFORE MEASUREMENT -  Avoid  eating,  smoking  or  exercising  30  minutes  before  taking measurements. Relax for 15 minutes before taking blood pressure. -  Stress  increases  blood  pressure.  Avoid  taking  measurements  during stressful periods. - You must take blood pressure in a calm environment and you must be relaxed and seated with your arm on a table. - Remain stationary and do not speak whilst taking blood pressure. - Users should not attempt to modify the device in any way. The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life.  4.7. INSTRUCTIONS   See diagram A page 2 -  Insert  the  cuff  tubing  connector  into  the  socket  in  the  left  side  of  the monitor. Make certain that the connector is completely inserted to avoid air leakage during blood pressure measurements -  Avoid  compression  or  restriction  of  the  connection  tube  during measurement  This  may  cause  inflation  error,  or  harmful  injury  due  to continuous cuff pressure.  Do  not  take  measurements  over  clothing.  Remove  jewelry from the arm you are measuring before taking measurement (watch, ring, bracelet, etc). - Sit down on a chair with your feet flat on the floor (do not cross your legs). - Ensure your smartphone or tablet with the Bew濸濿濿濖瀂瀁瀁濸濶瀇瀻澳濴瀃瀃澳濼瀆澳瀊濼瀇濻濼瀁澳reach. - Put the cuff around the arm with the orange marker at the bottom. - It must be 1-2 cm from elbow crease. The orange marker must lie on the 濼瀁瀆濼濷濸澳濴瀅瀀瀠瀆澳濴瀅瀇濸瀅瀌濁 - Close the Velcro (not too tight). - Press START/STOP to turn the blood pressure monitor on. - Put your arm on the table. - Remain seated and calm for 5 minutes before taking measurement. - Do not move during measurement. -  To  determine which  arm  you  will  continue  to  take  readings  on,  take  a measurement on both arms during your first reading. In the event of asymmetrical blood pressure (right systolic blood pressure-left systolic blood press >20 mmHg), take readings from the arm with the highest value except in the event of contraindications in this arm. - The measurement will be too low if the armband is higher than the heart or too high if it is lower than the heart.
                                                              Note:  For  more  reliable  results,  take  measurements  on  the  arm.  The measurement results are given for information. If in doubt about your results, please contact your doctor.  4.8. USER GUIDE Note:  For  an  initial  use,  please  insert  the  batteries  into  the  device  (see chapter 5) Setting the time -  The  time  is  set  automatically  during  the  synchronisation  of  your tensiometer with your smartphone/tablet. There are 2 measurement modes: MAM mode and Single mode MAM mode:  - Three arterial pressure measurements are repeated automatically with 15-second  intervals  between  each  measurement.  The  armband  inflates  and deflates  3  consecutive  times.  Do  not  remove  the  armband  before  all  3 pressure readings are finished. Single mode:  - A single measurement is taken.  濆濙濗濣濦濘濝濢濛澔濡濙濕濧濩濦濙濡濙濢濨濧澔濫濝濨濜澔濨濜濙澔澶濙濫濙濠濠澷濣濢濢濙濗濨瀜澔濕濤濤濠濝濗濕濨濝濣濢 - 濟濴瀈瀁濶濻澳瀇濻濸澳濕濸瀊濸濿濿濖瀂瀁瀁濸濶瀇瀻澳濴瀃瀃濿濼濶濴瀇濼瀂瀁澳濴瀁濷澳濶濿濼濶濾澳瀂瀁澳濠瀌濧濸瀁瀆濼瀂濁澳濔濶瀇濼瀉濴瀇濸澳Bluetooth on your smartphone or tablet. - Press the ON/OFF button to switch on the device. - The default measurement mode is MAM mode (3 measures). - 濣瀅濸瀆瀆澳瀇濻濸澳瀡濦濧濔濥濧澳濠濘濔濦濨濥濜濡濚瀢澳濵瀈瀇瀇瀂瀁澳濼瀁澳瀇濻濸澳濴瀃瀃濿濼濶濴瀇濼瀂瀁澳瀇瀂澳濿濴瀈瀁濶濻澳瀇濻濸澳measurement. The armband will inflate automatically. -  At  the  end  of  measuring,  the  results  are  automatically  transferred  via Bluetooth 4.0 and displayed on the application screen. - Press the ON/OFF button again to switch the device off. If you forget to switch it off, the device switches itself off after 2 minutes.  Rec濣濦濘濝濢濛澔濡濙濕濧濩濦濙濡濙濢濨濧澔濫濝濨濜濣濩濨澔濨濜濙澔澶濙濫濙濠濠澷濣濢濢濙濗濨瀜澔濕濤濤濠濝濗濕濨濝濣濢 You can also use your tensiometer without the MyTensio application, the measurements taken will not be saved in the tensiometer or in the phone. - Press the ON/OFF button to switch the device on.
                                                              -  Select  the  measuring  mode  by  pressing  the  START/STOP  button  for  5 seconds: MAM Mode (3 measurements) Single Mode (1 measurement) -  Press  START/STOP  to  begin  measuring.  The  armband  will  inflate automatically. - At the end of measuring, the results are displayed on the screen of the device. The colour code on the screen (green, orange, red) indicates your arterial pressure level based on the classification defined by ESH. - Press the ON/OFF button again to switch the device off. If you forget to switch it off, the device switches itself off after 2 minutes. Notes: - If you want to stop the blood pressure measurement at any point, press the ON /START to turn it off. - Speak to  your doctor if you have any questions  about using the blood pressure monitor. - You can also launch the measurement with the App.  5. INSERT OR REPLACE BATTERIES 濪濻濸瀁澳瀇濻濸澳濟濖濗澳瀆濻瀂瀊瀆澳瀇濻濸澳濵濴瀇瀇濸瀅瀌澳瀡澳 瀢澿澳瀅濸瀃濿濴濶濸澳濴濿濿澳濵濴瀇瀇濸瀅濼濸瀆澳瀊濼瀇濻澳瀁濸瀊澳瀂瀁濸瀆濁 1. Slide the battery cover in the direction of the arrow to open. 2.  Insert 4  alkaline AA  batteries  in the  correct polarity direction. Inserting  them  incorrectly  may  damage  the  device  and  the warranty.  Never  use  rechargeable  batteries.  Use  single  use batteries. 3. Replace the battery cover.  -  Disposal  of  discharged  batteries  to  the  authorized  collecting party subject to the regulation of each individual territory. - If the unit will not be used for a long period, please take out all batteries to avoid leakage damaging the unit.  6. HOW TO MAINTAIN AND STORE THE UNIT -  Use  a  dry  soft  cloth  to  clean  the  unit.  If  necessary,  use  a  cloth  lightly dampened with tap water. - Do not use alcohol, benzene, thinner or other harsh chemicals to clean the device or cuff. - Before using please wash your hands. Do not wash or wet the cuff. - Avoid placing the unit where there is direct sunlight, high humidity or dust. - Roll up the pressure armband and store in its case.  7. HOW TO PREVENT A MALFUNCTION - Do not drop the device and avoid sudden jars or shocks. - Do not insert other objects into any holes. - Do not attempt to disassemble the unit. - Do not put the unit in water. - The monitor might not meet its performance specifications or may cause safety  hazard  if  stored  or  used  outside  the  specified  temperature  and humidity ranges in specifications.  8. SPECIFICATIONS
                                                              Product Name Blood Pressure Monitor Model VMT-BPT1B Classification Class IIa Measuring method Oscillography system Indication Digital  LCD  Display  50*66mm  with Backlight: Green, Red, Yellow Dimensions 95*132*45mm Weight 245g Measuring range Cuff pressure: 0~299 mmHg. Systolic: 60~255mmHg Diastolic: 40~199mmHg Pulse: 40~180 Beat/min. Accuracy 濣瀅濸瀆瀆瀈瀅濸濍澳瀾濆瀀瀀濛濺 濣瀈濿瀆濸濍澳瀾濈澸澳瀂濹澳瀅濸濴濷濼瀁濺 Inflation Automatic inflating Deflation Automatic exhausting Function IHB icon WHO function Cuff Upper arm cuff 22-42cm Normal conditions of use   Temperature:10~40燠 Humidity:15~90%RH Barometric Pressure: 70~106kPa Storage conditions Temperature:    -25~70燠 Humidity: 0~90%RH Barometric Pressure: 80~105Kpa Technology While  Infalting  technology  (MWI)  - (Silent pump) Bluetooth Technology Bluetooth 4.0 Battery 4 AA alkaline batteries Device service life 2 years Automatic stop 2 minutes Voltage 3.7V low power Supplied with 1 device, 1 non-woven pouch, 1 user manual, 4 AA Alkaline batteries  9. TROUBLESHOOTING If  you  have  one  of  the  following  problems,  please  refer  to  this troubleshooting guide to help resolve the problem. If the problem persists, please contact customer service. PROBLEM POSSIBLE CAUSE SOLUTION LCD Display shows abnormal result The cuff is not positioned correctly or it  was  not  tight enough Put  the  cuff  on  correctly  and try again Incorrect  position during measurement 濥濸瀅濸濴濷澳 瀡濼瀁瀆瀇瀅瀈濶瀇濼瀂瀁瀆瀢澳 濴瀁濷澳retry You  spoke,  moved or were  agitated, excited, Try  again  when  you  have calmed down. Do not speak or move during test
                                                              or nervous during measurement. Arrhythmia The  appliance  is  not  suitable for people suffering from serious heart arrhythmia. LCD shows ERR You moved during measurement. Try again. Do not move during test No  response when you press button Low battery Change the batteries No  data  transfer to you smartphone/ tablet Bluetooth connection deactivated Activate  Bluetooth  on  your smartphone/tablet Incompatible smartphone or tablet Check  your  smartphone  or tablet has Bluetooth 4.0 The  3 measurements 濷瀂瀁瀠瀇澳 濶瀂瀀瀃濿濸瀇濸澿澳the measurement stops Poor  contact  with the armband Retake measurement Note: Relax for at least 10 minutes and then take another measurement.  10. EMC DECLARATION
                                                                 11. FCC COMPLIANCE This device complies with Part 15 of the FCC rules. Operation is subject to the  following  two  conditions:  (1)  this  device  may  not  cause  harmful interference,  and  (2)  this  device  must  accept  any  interference  received, including interference that may cause undesired operation. Caution:  changes  or  modifications  not  expressly  approved  by  the  party 瀅濸瀆瀃瀂瀁瀆濼濵濿濸澳濹瀂瀅澳濶瀂瀀瀃濿濼濴瀁濶濸澳濶瀂瀈濿濷澳瀉瀂濼濷澳瀇濻濸澳瀈瀆濸瀅瀠瀆澳濴瀈瀇濻瀂瀅濼瀇瀌澳瀇瀂澳瀂瀃濸瀅濴瀇濸澳瀇濻濸澳equipment. NOTE: this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,  may  cause  harmful  interference  to  radio  communications. However, there is no guarantee that interference will not occur in a particular installation. If  this  equipment  does  cause  harmful  interference  to  radio  or  television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.
                                                               12. CALIBRATION AND SERVICE - The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life. - It is generally recommended to have the unit inspected every two years to ensure  correct  functioning  and  accuracy.  Please  consult  your  local authorised distributor or dealer.  13. WARRANTY INFORMATION 濩濼瀆濼瀂瀀濸濷瀻澳瀊濼濿濿澳瀅濸瀃濴濼瀅澳瀂瀅澳瀅濸瀃濿濴濶濸澳瀇濻濼瀆澳瀃瀅瀂濷瀈濶瀇澳濹瀅濸濸澳瀂濹澳濶濻濴瀅濺濸澳濼瀁澳瀇濻濸澳濶濴瀆濸澳瀂濹澳defective parts or manufacturing defects, in accordance with the conditions mentioned below as follows:   DURATION: 24 MONTHS RETURN TO WORKSHOP LIMITS AND EXCLUSIONS: This guarantee concerns only the original final purchaser.  A  purchase  invoice,  or  another  proof  of  purchase,  with  this guarantee  card  will  be  required  to  obtain  an  after-sales  service,  in accordance with this guarantee. This guarantee card will not be extended to another person only the original final purchaser. This guarantee becomes void if the serial numbers on the product are modified, replaced, illegible, absent, or if repair has been carried out by a service not approved, including the user.   This guarantee covers only the defects of the material or parts, occurring during normal use of the pro-duct. It does not cover the damage caused during the transport of the apparatus, causes due to repairs being carried out by the distributor, by any modifications undertaken, any connection of 濸瀄瀈濼瀃瀀濸瀁瀇澳瀁瀂瀇澳濴瀃瀃瀅瀂瀉濸濷澳濵瀌澳濩濼瀆濼瀂瀀濸濷瀻澿澳瀂瀅澳濶濴瀈瀆濸瀆澳濶瀂瀁瀇瀅濴瀅瀌澳瀇瀂澳瀇濻瀂瀆濸澳瀊瀅濼瀇瀇濸瀁澳in  the user  manual or  notice.  Moreover,  the present  guarantee  does  not cover damage due to falls, bad handling, bad installations, damage by fire, floods,  lightning,  or  any  other  natural  disaster.  This  guarantee  does  not cover the  packing  of the material,  the accessories, the defects  caused  by commercial exposure of the product, show room, sale space, demonstration etc...  Normal  maintenance,  cleaning  and  the  replacement  of  parts  where 瀊濸濴瀅澳濼瀆澳瀁瀂瀅瀀濴濿澿澳濴瀅濸澳瀁瀂瀇澳濶瀂瀉濸瀅濸濷澳濵瀌澳瀇濻濸澳瀇濸瀅瀀瀆澳瀂濹澳瀇濻濼瀆澳濺瀈濴瀅濴瀁瀇濸濸濁澳濩濼瀆濼瀂瀀濸濷瀻澳and its representatives and agents will not in any case be held responsible for any damage and consecutive damages due to the mishandling of this 瀃瀅瀂濷瀈濶瀇濁澳 濧濻濼瀆澳 濺瀈濴瀅濴瀁瀇濸濸澳 濼瀆澳 瀇濻濸澳 瀂瀁濿瀌澳 瀉濴濿濼濷澳 瀂瀁濸澳 濴瀇澳 濩濼瀆濼瀂瀀濸濷瀻澿澳 濴瀁瀌澳 瀂瀇濻濸瀅澳guarantee (commercial  guarantee)  except  this  one  will  not be  taken  into account. IMPORTANT: During the guarantee period if you  are dissatisfied with the repairs of thi瀆澳瀃瀅瀂濷瀈濶瀇澿澳瀃濿濸濴瀆濸澳濶瀂瀁瀇濴濶瀇澳瀇濻濸澳濩濼瀆濼瀂瀀濸濷瀻澳濶瀈瀆瀇瀂瀀濸瀅澳瀆濸瀅瀉濼濶濸濁

Navigation menu