Visonic MCT370SMA5 MCT-370 SMA ZigBee Door/Window Contact User Manual

Visonic Ltd. MCT-370 SMA ZigBee Door/Window Contact

User Manual

MCT-370 Installation Instructions  MCT-370 SMA Door / Window Sensor  Installation Instructions  1. INTRODUCTION The MCT-370 is a fully supervised, wireless magnetic door / window sensor, for use with ZigBee enabled home security panels. The sensor includes a built-in reed switch that opens upon removal of a magnet placed near it.  The MCT-370 tamper switch is activated when the cover is removed. A  periodic  supervision  message  is  transmitted  automatically.  The  target  receiver  is thus  informed,  at  regular  intervals,  of  the  unit’s  active  participation  in  the  system. Operating power is obtained from an on-board 3 V Lithium battery. When the battery voltage  is  low,  a  “low  battery”  message  will  be  sent  to  the  receiver  60  days before expiration of battery life (for operation in room temperature).         2. SPECIFICATIONS WIRELESS Supported Network: ZigBee H.A 1.2 Frequency: 2.4 GHz as per IEEE 802.15.4 Tamper Alert: Reported when a tamper event occurs and in any subsequent message, until the tamper switch is restored. ELECTRICAL Internal Battery: 3V Lithium battery, type CR2. Use Panasonic only. Nominal Battery Capacity: 850 mAh Battery Life Expectancy: 5 years (for typical use). Note: Inability to connect with wireless network, or wireless link quality no higher than 20% may significantly reduce the expected battery life. Battery Power Test: Performed immediately upon battery insertion and periodically every several hours. Battery Supervision: Automatic transmission of battery condition data as part of any status report. ENVIRONMENTAL  Operating Temperature: 0C to 50C (32F to 122F) Humidity: 93% RH, non-condensing Dimensions: 59.5 x 29 x 11 mm (2-11/32 x 1-9/64 x 7/16 in.) Weight (including battery): 21.5g (0.8 oz) 3. ACTIVATING AND PAIRING THE SENSORTo pair the sensor to the security panel, you must set it to pairing mode. 1. Set the panel to pairing mode. 2. To activate pairing mode on the sensor, pull the activation strip from the back of the sensor (Figure 2). 3. The LED blinks 3 times every 5 seconds (repeated for up to 20 times) to indicate that the sensor is searching for a security panel.  Note: : If the sensor pairing is not successful during the searching process, restart it by tripping the reed switch or tamper switch of the door window sensor. 4. Complete the pairing procedure on the security panel. (See the pairing instructions in the security panel installation guide.) Note: Pairing should be done before installation.     4. INSTALLATION AND SENSOR TESTING CAUTION:  This  equipment  shall  be  installed  by  Service  Personnel  in  non-hazardous indoor locations only. 4.1 Mounting NOTE: It is highly recommended to attach the door / window sensor to the top of the door / window on the fixed frame and the magnet to the movable part (door or window). Make sure that the magnet is located not more than 6 mm (0.25 in.) from the sensor’s marked side.  The sensor should be mounted on the fixed surface and the magnet on the moving surface (see Figure 3b).       1. Peel away the release liners from the two strips of double-sided adhesive tape and attach to the device and magnet (see Figure 3a).                           OR Secure the device using the screws provided. a. Remove the cover by inserting a screw driver in the opening and pulling up. (see Figure 2). b.  Attach the mounting plate to the sensor with the two screws provided. c.  Place the cover onto the unit with the mounting plate installed. Make sure the tabs clear the cover, and then slide the cover onto the mounting plate.  2. Align the device with the magnet according to the location marks and fasten the device and magnet to the mounting surface. The sensor should be mounted on the fixed surface and magnet on the moving surface (see Figure 3b).  4.2 Magnet Mounting The magnet can be mounted with adhesive tape or screws. To mount the magnet with adhesive tape, it is optional to use one or two spacers (see Figure 4).                  To mount the magnet with screws, always use one spacer (see Figure 5). 1. Fasten the spacer to the mounting surface with two screws. 2. Locate the magnet on the spacer at the correct direction and push it upward.   4.2 Sensor Testing 1. Open and close the door or window and confirm the status is properly updated on the security panel. 2. Perform the signal strength testing procedure to make sure the device has a good signal.  This procedure is described in the security panel installation manual.        Door / Window Sensor Magnet Activation Strip A 1 2 Magnet Figure 1 – External View Figure 2 – Activation Strip  Fig. 5  – Magnet Mounting  Fig. 3b – Mounting on Fixed Surface A. Double-sided adhesive tape   Opening to remove cover Fig. 3a – Attaching the Adhesive Tape Fig. 4  – Magnet Mounting with Spacers
 2  MCT-370 Installation Instructions 5. BATTERY REPLACEMENT  Fig. 4a – Opening Battery Cover  Fig. 4b –Replacing Battery 1. Press down on the battery cover and slide in the direction shown to open it  (see Figure 4a). 2. Lift the battery from the compartment. 3. Insert the new battery into the sensor while observing battery polarity (see Figure 4b). 4. Close the battery cover. Note: The required battery is CR2 Lithium 3V, manufactured by Panasonic. Caution! There is risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according to the manufacturer's instructions. 6. DEFAULTING THE SENSOR CAUTION! The defaulting process removes the device from the network and enables re-pairing. Open the battery cover and pull back the clip to remove the battery (see Figure 4). 1. Press and hold down the sensor’s tamper switch (see Figure 4b). 2. Insert the battery into the sensor while observing battery polarity (see Figure 4b). 3. Release the tamper switch within 4 seconds. The LED will blink 3 times every 5 seconds to indicate successful default. 4. To re-pair the sensor, follow the instructions in section 3.  7. TROUBLESHOOTING If you encounter one of the following problems with the MCT-370, do the suggested remedy: Problem Remedy Attempt to pair the sensor is unsuccessful. Make sure that the sensor has been defaulted and is set to pairing mode (see section 7). Make sure the security panel supports the MCT-370. The sensor and the panel do not communicate. Perform the signal strength testing procedure described in the security panel installation manual. Make sure that the signal is sufficient. If necessary, replace the sensor’s battery. Problem Remedy The sensor sends a Low Battery indication. To ensure continuous proper operation, replace the battery within two weeks of the first Low Battery indication (see section 5). Panel does not arm because of an unrecognized sensor malfunction Consult with your installer or system provider before you disable a zone. Disable the detector zone (see the security panel user manual). Note that disabling a sensor zone lowers the overall security level of your system. 8. COMPLIANCE WITH STANDARDS USA/CANADA FCC USA: CFR 47 part 15, Canada: RSS 247. This device complies with Part 15 of the FCC Rules and RSS-247 of Industry and Science Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.      FCC ID: WP3MCT370SMA5 IC: 1467C-MCT370SMA    USA/CANADA Complies with: ANSI/UL 634, ULC/ORD – C634 FCC Compliance Statement This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable  protection  against  harmful  interference  in  residential  installations.  This equipment  generates  uses  and  can  radiate  radio  frequency  energy  and,  if  not installed  and  used  in  accordance  with  the  instructions,  may  cause  harmful interference to radio and television reception. However,  there  is  no  guarantee  that  interference  will  not  occur  in  a  particular installation.  If  this  device  does  cause  such  interference,  which  can  be  verified  by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: – Re-orient or re-locate the receiving antenna. – Increase the distance between the device and the receiver. –  Connect  the  device  to  an outlet  on  a  circuit  different  from  the  one  that  supplies power to the receiver. – Consult the dealer or an experienced radio/TV technician. WARNING! Changes  or modifications  to this unit not expressly approved  by  the party responsible for compliance could void the user’s authority to operate the equipment. Reed Switch Positions Note: Dimensions in the following table are typical.  Wood Supports Iron Opening Closing Direction Opening Closing 15 mm 14 mm X 13 mm 12 mm 29 mm 24 mm Y 11 mm 8 mm 37 mm 31 mm Z 11 mm 8 mm 9. PRODUCT LIMITATIONS Visonic Ltd. wireless systems are very reliable and are tested to high standards. However, due  to  low  transmitting  power  and  limited  range  (required  by  FCC  and  other  regulatory authorities), there are some limitations to be considered: A.  Receivers  may  be  blocked  by  radio  signals  occurring  on  or  near  their  operating frequencies, regardless of the digital code used. B.  A receiver responds only to one transmitted signal at a time. C.  Wireless devices should be tested regularly to determine whether there are sources of interference and to protect against faults. The  user  is  cautioned  that  changes  or  modifications  to  the  unit,  not  expressly approved by Visonic Ltd., could void the user’s FCC or other authority to operate the equipment.     W.E.E.E. Product Recycling Declaration For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste. Directive 2002/96/EC Waste Electrical and Electronic Equipment. This device complies with the essential requirements and provisions of Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio and telecommunications terminal equipment.        EMAIL: info@visonic.com INTERNET: www.visonic.com VISONIC LTD. 2016      MCT-370   (Rev 1, 1/16)       Please refer to the separate Warranty statement         Y Z Z Figure 5 - Range Coverage Directions X Y X X Y Z RF Exposure Information This equipment complies with FCC and Industry Canada radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the  FCC and IC radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm during normal operation.

Navigation menu