Visonic MP802PG2 Wireless Digital Pet Immune PIR Detector User Manual MP 802 K9 85 PG2 Installation Instructions
Visonic Ltd. Wireless Digital Pet Immune PIR Detector MP 802 K9 85 PG2 Installation Instructions
Visonic >
Contents
- 1. Users Manual
- 2. Users Manual_1
- 3. Users Manual_2
Users Manual


![2.3. Removing the Pet MaskRemove the plastic (pet mask) if you do not require pet immunity.Figure 10 - Removing the Pet Mask1. Place your thumb at the base of the Pet Mask.2. Place your fingers at the top of the Pet Mask.3. Lift the Pet Mask to remove.2.4. Disassembly from BracketFigure 11 - Disassembly from Bracket1. Release screw.2. Separate the cover from the base.3. Remove battery.4. Press on the stopper snap to release the base from the bracket.5. Slide the base downward to remove.2.5. EnrollmentRefer to the PowerMaster panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES" option of the Installer Menu. A generaldescription of the procedure is provided in the following flow chart.Step Procedure Menu1 Enter the installer menu and select “02:ZONES/DEVICES” 02:ZONES/DEVICES2 Select “ADD NEW DEVICES” Option – See Note [1]ADD NEW DEVICES↓MODIFY DEVICESD-306133 MP-802 K9-85 PG2 Installation Instructions 3](https://usermanual.wiki/Visonic/MP802PG2.Users-Manual/User-Guide-3269823-Page-3.png)
![3Select “ADD NEW DEVICES” Option – See Note [1] Enroll the device or enter thedevice ID ENROLL NOW or ENTR ID:XXX-XXXX4 Select the desired Zone NumberZ14:Motion Sens (with panels PowerG V19.2 andlower)ID No. 120-XXXX (with panels PowerG V19.2 andlower)Z14:S.Motion (with panels PowerG V19.3 and higher)ID No. 126-XXXX (with panels PowerG V19.3 andhigher)5 Configure Location, Zone Type & Chime ParametersZ14:LOCATIONZ14:ZONE TYPEZ14:SET CHIMEZ14 :DEV SETTINGS6 Configure the detector See Note 2Notes:[1] If the detector is already enrolled, you can configure the detector parameters via the modify devices option – see step 2.[2] Select the “Device Settings” option and refer to section 3 to configure the detector parameters.3. Temperature DisplayFor instructions on displaying the temperature of zones on the control panel as measured by MP-802 PG2 detectors, refer to the PowerMaster InstallerGuide, section 4.2 “Conducting a Periodic Test”.4. Configuring the Detector ParametersEnter the DEVICE SETTINGS menu and follow the configuration instructions for the MCP-802 K9-85 PG2 detector as described in the following table.Option Configuring InstructionsAlarm LED Define whether or not the alarm LED indication will be activated. Optional settings: LED ON (default) and LED OFF.EventCounterDefine whether an alarm will be activated upon continued motion (low sensitivity) or upon a single alarm event (high sensitivity).Optional settings: LOW sensitive (default) and HIGH sensitive.DISARMActivityDefine whether or not to set the activity time during disarm. Optional settings: NOT Active (default), YES – no delay, YES + 5s delay,YES + 15s delay, YES + 30s delay, YES + 1m delay, YES + 2m delay, YES + 5m delay, YES + 10m delay, YES + 20m delay and YES +60m delay.VERY HOT> 35°C [ >95°F]Define whether or not the control panel will report a "very hot" alert when the temperature rises above 35°C (95°F) for at least 10minutes. Alert restore will occur when the temperature drops below 34°C (93°F) for the duration of 10 minutes. Optional settings:Disable (default) or EnableCOLD <19°C [ <66°F]*Define whether or not the control panel will report a "cold" alert when the temperature drops below 19°C (66°F) for at least 10minutes. Alert restore will occur when the temperature rises above 20°C (68°F) for the duration of 10 minutes. Optional settings:Disable (default) or EnableFREEZING< 7°C [ <45°F]*Define whether or not the control panel will report a "freezing" alert when the temperature drops below 7°C (45°F) for at least 10minutes. Alert restore will occur when the temperature rises above 8°C (48°F) for the duration of 10 minutes. Optional settings:Disable (default) or EnableFREEZER> -10°C [ <14°F]*Define whether or not the control panel will report a "freezer" alert when the temperature rises above -10°C (14°F) for at least 30minutes. Alert restore will occur when the temperature drops below -11°C (12°F) for the duration of 10 minutes. Optional settings:Disable (default) or EnableNote: The temperature must pass beyond the threshold for the required duration in order to generate an alarm or restore transmission.5. LOCAL DIAGNOSTICS TESTNote: Run a diagnostic test at least once a year to ensure that the detector is working correctly.1. Separate the base from the cover (see Figure 5).2. Replace the cover to return the tamper switch to its normal (undisturbed) position, and then secure the front cover to the base with the case closurescrew.3. The MP-802 K9-85 PG2 detector will enter a 2 min. stability period. During this time the red LED blinks.4. Walk-test the coverage area – see Figure 12. Walk across the far end of the coverage pattern in both directions. The red LED lights each time yourmotion is detected followed by 3 LED blinks.The following table outlines received signal strength indication:D-306133 MP-802 K9-85 PG2 Installation Instructions 4](https://usermanual.wiki/Visonic/MP802PG2.Users-Manual/User-Guide-3269823-Page-4.png)
![LED response ReceptionGreen LED blinks StrongOrange LED blinks GoodRed LED blinks PoorNo blinks No communicationImportant! Instruct the user to walk test at least once a week to verify proper function of the detector.Important! Reliable reception must be assured. Therefore, poor signal strength is not acceptable. If you receive a poor signal from the device, re-locate it and re-test until a good or strong signal strength is received (in regions requiring UL-compliant installation, only strong signal strength ispermitted).Notes:[1] For detailed diagnostics test instructions, refer to the control panel Installer Guide.**This menu appears in PowerMaster V19.3 or above only. In earlier versions, this menu will appear only after completing the following procedure:a. Upgrade the PowerMaster control panel to V19.3 or above.b. Delete the MP-802 K9-85 PG2 detector from the PowerMaster control panel.c. Enroll the detector to the PowerMaster control panel again.6. TROUBLESHOOTINGIf you encounter one of the following problemswith the MP-802 K9-85 PG2, perform the suggested remedy from the following table:Problem RemedyAttempt to enroll the sensor is unsuccessful. Ensure that the sensor has been defaulted and is set to enroll mode (seesection 2.5)The sensor and the panel do not communicate. Perform the signal strength testing procedure described in the controlpanel installation manual. Make sure that the signal is sufficient. Ifnecessary, replace the sensor's battery.The sensor sends a low battery indication. To ensure continuous proper operation, replace the battery within twoweeks of the first low battery indication.Panel does not arm because of an unrecognized sensor malfunction. Consult with your installer or system provider before youdisable a zone.Disable the sensor zone (see the control panel user manual). Note thatdisabling a sensor zone lowers the overall security level of your system.7. COMPLIANCE WITH STANDARDSThe MP-802 K9-85 PG2 complies with the following standards:Europe:EN 300220, EN 301489, EN 60950-1, EN 50130-4, EN 50131-1, EN 50131-2-2 Grade 2 Class II, EN 50130-5, EN 50131-6 Type CUK: The MP-802 K9-85 PG2 is suitable for use in systems installed to conform to PD6662:2010 at Grade 2 and environmental CLASS II. DD243 and BS8243Certified by Applica Test & Certification AS in accordance with EN 50131-2-2, EN 50131-5-3, EN 50131-6, EN 50130-4, EN 50130-5 Applica T&C has certifiedonly the 868 MHz variant of this product.The MP-802 K9-85 PG2 is compatible with the RED Directive 2014/53/EU of the European Parliament and of the Council of 16 April 2014USA: FCC-CFR 47 Part 15, UL- UL 639Canada:IC-RSS 247, ULC – S306This device complies with Part 15 of the FCC Rules and RSS-247 of Industry and Science Canada. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may causeundesired operation.Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deuxconditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,même si le brouillage est susceptible d'en compromettre le fonctionnement.WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority tooperate the equipment.To comply with FCC and IC RF exposure compliance requirements, the device should be located at a distance of at least 20 cm from all persons duringnormal operation. The antennas used for this product must not be co-located or operated in conjunction with any other antenna or transmitter.Le dispositif doit être placé à une distance d'au moins 20 cm à partir de toutes les personnes au cours de son fonctionnement normal. Les antennesutilisées pour ce produit ne doivent pas être situés ou exploités conjointement avec une autre antenne ou transmetteur.D-306133 MP-802 K9-85 PG2 Installation Instructions 5](https://usermanual.wiki/Visonic/MP802PG2.Users-Manual/User-Guide-3269823-Page-5.png)