Visonic PMEXPRESS FULLY SUPERVISED WIRELESS ALARM CONTROL SYSTEM User Manual 1
Visonic Ltd. FULLY SUPERVISED WIRELESS ALARM CONTROL SYSTEM Users Manual 1
Visonic >
Contents
- 1. Users Manual 1
- 2. Users Manual 2
Users Manual 1
PowerMaxExpress Installer Guide Fully Supervised Wireless Alarm Control System TABLE OF CONTENTS 1. INTRODUCTION ....................................................... 3 2. SPECIFICATIONS..................................................... 3 2.1 General Data....................................................... 3 2.2 RF Section .......................................................... 3 2.3 Electrical Data ..................................................... 3 2.4 Communication ................................................... 4 2.5 Physical Properties ............................................. 4 3. INSTALLATION ......................................................... 4 3.1 Unpacking the Equipment................................... 4 3.2 Supplying Power to the Unit................................ 4 3.3 System Planning & Programming ....................... 4 3.4 Mounting ............................................................. 4 3.5 Wiring .................................................................. 4 3.6 Backup Battery Insertion..................................... 6 3.7 Optional GSM Module Mounting ........................... 7 3.8 Power Cable Connection .................................... 7 3.9 Control Panel Final Closure ................................ 7 4. PROGRAMMING....................................................... 8 4.1 INTRODUCTION ................................................ 8 4.1.1 General Guidance............................................ 8 4.1.2 Entering an Invalid Installer Code ....................... 8 4.1.3 Installerâs Menu ................................................ 8 4.1.4 Setting a New Installer Code ........................... 8 4.1.5 Setting a New Installer Code in PowerMaxExpress that has 2 Installer Codes ........... 8 4.2 ENROLLING WIRELESS DEVICES AND KEYFOB TRANSMITTERS........................................................... 9 4.2.1 General Guidance............................................ 9 4.2.2 Enrolling Type .................................................. 9 4.2.3 Enroll/Delete Sensors ...................................... 9 4.2.4 Enroll/Delete Keyfob Transmitters ......................... 9 4.2.5 Enroll/Delete Wireless Commander........................ 9 4.2.6 Enroll/Delete 2-Way Keypad ............................ 9 4.2.7 Enroll/Delete Wireless Siren............................. 9 4.3 DEFINING ZONE TYPES, NAMES, CHIME ZONES & PARTITION .............................................................. 11 4.4 DEFINING CONTROL PANEL PARAMETERS .... 12 4.4.1 Preliminary Guidance..................................... 12 4.4.2 Entry Delays 1&2 ............................................. 12 4.4.3 Exit Delay ....................................................... 12 4.4.4 Bell Time ........................................................ 12 4.4.5 Abort Time...................................................... 12 4.4.6 Alarm Cancel.................................................. 12 4.4.7 Quick Arm ...................................................... 12 4.4.8 Bypass............................................................ 12 4.4.9 Exit Mode ....................................................... 13 4.4.10 Piezo Beeps ................................................. 13 4.4.11 Trouble Beeps.............................................. 13 4.4.12 Panic Alarm.................................................. 13 4.4.13 Swinger Stop................................................ 13 4.4.14 Cross Zoning................................................ 13 4.4.15 Supervision .................................................. 13 4.4.16 NOT READY ................................................ 13 4.4.17 AUX Button A ............................................... 13 4.4.18 AUX Button B 2-W-KF.................................... 13 D-302017 4.4.19 Jam Detect................................................... 13 4.4.20 Latchkey....................................................... 14 4.4.21 âNot Activeâ .................................................. 14 4.4.23 Duress.......................................................... 14 4.4.24 Piezo Siren................................................... 14 4.4.25 Reset Option ................................................ 14 4.4.26 Tamper Option ............................................. 14 4.4.27 Siren On Line ............................................... 14 4.4.28 Memory Prompt ........................................... 14 4.4.29 Disarm Option .............................................. 14 4.4.30 Bell/Rep. Option........................................... 14 4.4.31 Low-Bat Ack................................................. 14 4.4.32 Screen Saver ............................................... 14 4.4.33 Confirm Alarm .............................................. 14 4.4.34 AC FAIL REP ............................................... 14 4.4.36 User Permission .......................................... 15 4.4.39 Key Zones Options (Optional) ..................... 15 4.5 DEFINING COMMUNICATION PARAMETERS... 17 Preliminary Guidance.............................................. 17 4.5.1 PSTN / GSM (Fig. 4.5 Detail A) ....................... 17 4.5.2 GPRS / BB [Fig. 4.5 Detail B] ........................ 17 4.5.3 C.S. Reporting (Fig. 4.5 Detail C).................. 18 4.5.4 Private Report (Fig. 4.5 Detail D) .................... 19 4.6 GSM Auto Detection.............................................. 23 4.7 BBA Auto Detection............................................... 23 4.9 DEFINE CUSTOM................................................. 24 4.10 DIAGNOSTIC TEST ............................................ 24 4.11 USER FUNCTIONS ............................................ 25 4.12 RETRIEVING FACTORY DEFAULTS ................ 25 4.13 SERIAL NUMBER ............................................... 25 4.14 CALLING UPLOAD/DOWNLOAD SERVER....... 25 4.15 ENABLING/DISABLING PARTITIONS ............... 26 4.16 WALK-TEST ........................................................ 26 5. TESTING PROCEDURES ...................................... 27 5.1 Preparations...................................................... 27 5.2 Diagnostic Test ................................................. 27 5.3 Keyfob Transmitter Test ................................... 27 5.4 Emergency Transmitter Test ............................ 27 6. MAINTENANCE ...................................................... 27 6.1 Dismounting the Control Panel......................... 27 6.2 Replacing the Backup Battery .......................... 27 6.3 Fuse Replacement............................................ 27 6.4 Replacing/Relocating Detectors ....................... 27 7. READING THE EVENT LOG .................................. 27 APPENDIX A. Detector Deployment & Transmitter Assignments ................................................................ 29 A1. Detector Deployment Plan.................................. 29 A2. Keyfob Transmitter List....................................... 29 A3. Emergency Transmitter List................................ 30 A4. Non-Alarm Transmitter List................................. 30 APPENDIX B. Event Codes ........................................ 31 Contact ID Event Codes ......................................... 31 SIA Event Codes..................................................... 31 4/2 Event Codes...................................................... 31 Understanding the Scancom Reporting Protocol Data Format ..................................................................... 32 C6. Interior Zone ..................................................... 33 C7. Interior Follower Zones .................................... 33 C8. Non-Alarm Zones ............................................. 33 C9. Perimeter Zones............................................... 33 C10. Perimeter Follower Zones .............................. 33 C11. 24-Hour Zones ............................................... 33 APPENDIX C. Programmable Zone Types ................. 33 C1. Delay Zones....................................................... 33 C2. Emergency Zones.............................................. 33 C3. Fire Zones ........................................................ 33 C4. Flood Zone ....................................................... 33 C5. Gas Zone.......................................................... 33 APPENDIX D. PowerMaxExpress Compatible Devices ..................................................................................... 34 D1. PowerMaxExpress Compatible Detectors ........ 34 D2. PowerMaxExpress Compatible Transmitters... 34 D3. PowerMaxExpress Compatible WL Siren........ 35 MESSAGE TO THE INSTALLER The PowerMaxExpress control panel is supplied with 2 instruction manuals: Installer Guide (this manual - for your exclusive use) Userâs Guide (for your use during installation only - Must be handed over to the master user after testing the system). Appendices A.1 and A.2 will help you prepare an installation plan. Please take time to fill out the forms - your job will become much easier and confusion will be prevented. Filling out the forms will also help you create a list of detectors and transmitters that must be obtained for the particular application. Compatible detectors and transmitters are listed and described briefly in Appendix D. Remember - it is advisable to power up the control panel temporarily after unpacking and program it on the work bench, in accordance with the installation plan. The programming flow charts in the programming section show all options available for each parameter. Factory defaults are marked with a dark box to their right, and other options (that can be selected instead) are marked by clear boxes. This method allows you to put a checkmark in the appropriate clear box whenever you deviate from the factory defaults. Most of the programming section paragraph numbers correlate with the programming menu numbers. For example, paragraph 4.4.19 describes the "Jam detect", that exists in menu 4 (define panel), sub-menu 19 (Jam detect). Although setting the correct time and date is one of the user tasks, we recommend that you set the time and date in the course of programming. Access to the âUser Settingsâ for the installer is possible through item 10 on the installerâs menu or through the user menu (see Userâs manual section 7). After programming, proceed to install the system as detailed in the Installation Instructions, from paragraph 3.4 onward. The installer should verify line seizure. Be aware of other phone line services such as DSL. If DSL service is present on the phone line, you must install a filter. It is suggested to use the DSL alarm filter model Z-A431PJ31X manufactured by Excelsus Technologies, or equivalent. This filter simply plugs into the RJ-31X jack and allows alarm reporting without breaking the internet connection. D-302017 1. INTRODUCTION The PowerMaxExpress is a user and installer-friendly, 29zone fully-supervised wireless control system. IMPORTANT NOTE: Partitioning refers only to purchased control panels that support the partitioning feature. The PowerMaxExpress includes an optional partition feature. Partitioning allows you to have up to four independently controllable areas with different user codes assigned to each partition. A partition can be armed or disarmed regardless of the status of the other partitions within the system. For example, you can define the garage as partition 1, the basement as partition 2, the house as partition 3 and a safe as partition 4. Since each partition is independent of other partitions, you can arm or disarm each partition as desired without altering the states of the other partitions. Therefore, while arming or disarming your home this will not interfere with the safe that you desire to arm most of the time. The system is designed to function in an appealing way to the user and also offers features that make installersâ life easier than ever before: EASY TO MAINTAIN ⢠Alarm memory and trouble data are displayed upon request. ⢠Diagnostic test provides visual and audible indication of the signal level of each detector. ⢠Remote control from distant telephones. ⢠Event log stores and displays information. ⢠Upload / download from distant computer via telephone line or cellular modem. QUICK PROGRAMMING ⢠Simple programming logic, fully menu driven. ⢠Multiple-choice selection of options for each parameter. ⢠Unequivocal visual prompts. ⢠Installer access to the user menu. 2. SPECIFICATIONS 2.1 General Data Zones Number: 28 wireless zones, 1 hardwired input. Hardwired Zone Requirements: 2.2 kΊ E.O.L. resistance (max. resistance of wires 220 Ί). Zone Types: Interior follower, interior, perimeter, perimeter follower, delay 1, delay 2, 24h silent, 24h audible, fire, non-alarm, emergency, gas, flood, temperature and home/delay. User Codes: 8 codes, 4 digits each (9999 different combinations). Code 0000 is not allowed. Control Facilities: - Integral keypad - PowerCode / Code-Secure⢠hand-held transmitters. - One way / two way keypads. - SMS commands via optional GSM/GPRS module. - Remote control by telephone. Display: Single line, 16-character LCD. Arming Modes: AWAY, HOME, AWAY-INSTANT, HOMEINSTANT, LATCHKEY, FORCED, BYPASS. Alarm inhibited during a single arming period (swinger stop) after: 1, 2, 3, alarm/tamper/fault, or not inhibited (programmable / selectable). Alarm Types: Silent alarm, siren alarm (future option) or sounder (internal) alarm, in accordance with zone attributes. Siren Signals: Continuous (intrusion / 24 hours / panic); triple pulse - pause - triple pulse... (fire). Siren (bell) Timeout: Programmable (4 min. by default). Internal Sounder Output: At least 85 dBA at 10 ft (3 m). Supervision: Programmable time frame for inactivity alert Special Functions: - Chime zones - Diagnostic test and event log. - Local and Remote Programming over Telephone, GSM /GPRS connections. - Calling for help by using an emergency transmitter. - Tracking inactivity of elderly, physically handicapped and infirm people. Data Retrieval: Alarm memory, trouble, event log. D-302017 Real Time Clock (RTC): The control panel keeps and displays time and date. This feature is also used for the log file by providing the date and time of each event. Compliance with U.S. Standards: Meets FCC 47 Part 15 and Part 68 requirements. Compliance with European CE Standards: EN 50082-1, EN301489-3,7, EN6100-4-6, EN60950, EN300220, EN50130-4, EN50130-5, EN50131-3 The PowerMaxExpress is compatible with the RTTE requirements - Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999. According to the European standard EN50131-1, the PowerMaxExpress security grading is 2 â "low to medium risk" and environmental classification is II â "indoor general" and the power supply type is A. GSM standards: Europe : Complies with CE standards 3GPP TS 51.0101, EN 301 511, EN 50361, EN301489-7 USA: FCC 47 Part 22 (GSM850) and Part 24 (GSM 1900). EMC standard: FCC 47 Part 15. SAR standards: FCC rule 2.1093, FCC Docket 96-326 & Supplement C to OET Bulletin 65 2.2 RF Section Operating Frequencies (MHz): 315 (in USA & Canada), 433, 868.95 or other UHF channel per local requirement in the country of use. Receiver Type: Super-heterodyne, fixed frequency Receiver Range: 600 ft (180 m) in open space Antenna Type: Spatial diversity Coding: PowerCode and/or CodeSecure⢠2.3 Electrical Data External AC/AC adapter: ⢠Europe: 230VAC 50Hz input, 9VAC 700mA output. ⢠USA: 120VAC 60Hz input, 9VAC 1000mA output. Current Drain: Approx. 70 mA standby, 1600 mA peak at full load. Minimum battery voltage: 4.8V Backup Battery Pack: 4.8V 1300 mAh, rechargeable NiMH battery pack, p/n GP130AAM44MX, manufactured by GP â Backup period of 16 hours. Maximum battery recharge time: 72 hours Battery Test: Once every 10 seconds. 2.4 Communication Built-in Modem: 300 baud, Bell 103 protocol Data Transfer to Local Computer: Via RS232 serial port Report Destinations: 2 central stations, 4 private telephones. Reporting Format Options: SIA, Pulse 4/2 1900/1400 Hz, Pulse 4/2 1800/2300 Hz, Contact ID, Scancom. Pulse Rate: 10, 20, 33 and 40 pps - programmable Message to Private Phones: Tone Ring Detection: The unit does not support ring detection without DC voltage present on the telephone lines. 2.5 Physical Properties Operating Temp. Range: 14°F to 120°F (-10°C to 49°C) Storage Temp. Range: -4°F to 140°F (-20°C to 60°C) Humidity: 85% relative humidity, @ 30°C (86°F) Size: 193 x 178 x 50 mm (7-5/8 x 7 x 2 in.) Weight: 658g (23 Oz) (with battery) Color: White 3. INSTALLATION 3.1 Unpacking the Equipment Open the cardboard packing box and check whether all items have been included. If you find out that an item is missing, contact your vendor or dealer immediately. 3.2 Supplying Power to the Unit Connect power to the PowerMaxExpress temporarily (see figure 3.7). Alternatively, you may power up from the backup battery, as shown in figure 3.3. Disregard any âtroubleâ indications pertaining to lack of battery or lack of telephone line connection. 3.3 System Planning & Programming It pays to plan ahead - use the tables in appendices A and B at the end of this guide to register the intended location of each detector, the holder and assignment of each transmitter. Gather up all transmitters and detectors used in the system and mark each one in accordance with your deployment plan. Program the system now as instructed in the programming section. 3.4 Mounting Required tool: Philips screwdriver #2. PowerMaxExpress mounting process is shown in figure 3.1 - 3.8. 3.5 Wiring Required tools: Cutter and slotted screwdriver - 3 mm blade. PowerMaxExpress wiring is shown in figure 3.2. D-302017 Remove front cover Back unit Mark 4 drilling points on mounting surface Release screws Fasten the back unit with 4 screws Drill 4 holes and insert wall anchors Figure 3.1 â Back Unit Mounting CABLES ROUTING GUIDE Cables entry possibilities Cable clips Remove the left or right side cables entry knockout(s) and enter the required cable(s). D-302017 (example) Remove and use as cable clamp(s) PHONE WIRING Connect telephone cable to SET connector and telephone line cable to LINE connector (through the desired wiring cable entry). PHONE WIRING IN NORTH AMERICA 8-POSITION RJ-31X PLUG RJ-31X JACK GRAY BROWN RED 3 4 RED RJ-31X GREEN GRAY 6 5 LINE FROM STREET HOUSE PHONES GRN BROWN RJ-31X CORD ZONE & EXTERNAL SIREN WIRING SITE EXTERNAL SIREN (FUTURE OPTION) 2.2 kΊ MAGNETIC CONTACT OR ANY OTHER CONTACT (NOT A DETECTOR) Alarm N.C. Figure 3.2 - Wiring WARNING! When plugging SIREN & ZONE terminals back into place, be sure to align them carefully with the pins on the PCB. Misaligned or reverse insertion of terminals may damage internal PowerMaxExpress circuits! 3.6 Backup Battery Insertion Connect battery pack as shown in the next drawing. D-302017 1 3.8 Power Cable Connection Battery insertion Connect the power cable and close the control panel as shown below. Electrical socket-outlet shall be installed near the equipment and shall be easily accessible. Connect the power adapter to the power connector. Battery connection Figure 3.3 - Battery Insertion 3.7 Optional GSM Module Mounting Note: The GSM module is used with an internal antenna. Optional external antenna can be used. Caution: Do not install or remove the GSM module when the system is powered by AC power or backup battery. 1. Plug in the GSM Module and fasten it as follows: Fig. 3.6 - Power Cable Connection 3.9 Control Panel Final Closure Control panel final closure is shown below. Close front cover GSM Front unit Fasten screws Figure 3.4 - Optional GSM Module Mounting 2. Insert the SIM card into the GSM module Figure 3.7 - Final Closure SIM card insertion Slide top cover Slide SIM card into cover Open cover Align SIM card in cover (note cover orientation) Rotate cover Lock cover to close to close IMPORTANT Do not insert or remove SIM card when the control panel is powered by AC power or battery. Figure 3.5 - SIM Card insertion D-302017 4. PROGRAMMING 4.1 INTRODUCTION 4.1.1 General Guidance We recommend to program the PowerMaxExpress on the work bench before actual installation. Operating power may be obtained from the backup battery or from the AC power supply. The installerâs menu is accessible only to those who know the installerâs 4-digit code, which is 9999 by factory default. Note: Access to the installer menu, in PowerMaxExpress that has "User Permission" enabled (for example in UK) is accessible only at the end of the user menu. This option can be changed if necessary (see par. 4.4.36). For PowerMaxExpress that has 2 installer codes (not applicable in UK), the default INSTALLER code is 8888 and the default MASTER INSTALLER code is 9999. The following actions can be done only by using the master installer code: ⢠Changing master installer code. ⢠Resetting the PowerMaxExpress parameters to the default parameters, ⢠Defining specific communication parameters, as detailed in a note in figure 4.5C. Obviously, you are expected to use this code only once for gaining initial access, and replace it with a secret code known only to yourself. You will mainly use 5 control pushbuttons during the entire programming process: - to move one step forward in a menu. - to move one step backward in a menu. I OK - to enter the relevant menu or confirm data. 4.1.5 Setting a New Installer Code in PowerMaxExpress that has Installer Codes For PowerMaxExpress with 2 installer codes, INSTALLER code (default 8888) and MASTER INSTALLER code (default 9999), set new codes as shown in figure 4.1c. For details regarding the different authorization levels when logging in with installer code and master installer code, refer to the note inside figure 4.5C (DEFINE COMM). By using the master installer code, the menu enables changing both master installer code and installer code. By using the installer code, the menu enables changing the installer code only. (First display) READY 00:00 WALK TEST USER SETTING (*) INSTALLER MODE ENTER CODE [installer code] 1. NEW INSTL CODE (See fig. 4.1b & 4.1c) 2. ENROLLING (See figure 4.2) 3. DEFINE ZONES (See figure 4.3) 4. DEFINE PANEL (See figure 4.4) 5. DEFINE COMM. (See figure 4.5) 9. DEFINE CUSTOM (See figure 4.9) 10. DIAGNOSTICS (See figure 4.10) 11. USER SETTINGS (See chapter 7 in User Guide) 12. FACTORY DEFLT (See par. 4.12) 13. SERIAL NUMBER (Control Panel serial number display) 14. START UL/DL (See section 4.14) - to move one level up in a menu. - to return to the "OK TO EXIT" state. The sounds you will hear while programming are: - Single beep, heard whenever a key is pressed. âş - Double beep, indicates automatic return to the normal operating mode (by timeout). - Happy Melody (- - - âââ), indicates successful completion of an operation. - Sad Melody (âââââ), indicates a wrong move or rejection. 4.1.2 Entering an Invalid Installer Code If you enter an invalid installer code 5 times, the keypad will be automatically disabled for 90 seconds and the message WRONG PASSWORD will be displayed. 4.1.3 Installerâs Menu The installer's menu is shown in figure 4.1a. The text in rectangles represents the current PowerMaxExpress display. (**) 15. PARTITIONING (See figure 4.15)TO EXIT (*) Applicable only when "USER PERMIT" function is enabled (see par. 4.4.36 - USER PERMIT) (**) Optional feature. Figure 4.1a - Installerâs Menu (See fig. 4.1a) 1. NEW INSTL CODE 4.1.4 Setting a New Installer Code NEW INST. CODE To set an installer code, perform the actions that are presented in figure 4.1b. When you are instructed to enter code, enter a 4-digit code. INST. CODE xxxx [code] Figure 4.1b - Setting a New Installer Code (see note) D-302017 By using INSTALLER CODE By using MASTER INSTALLER CODE 1. NEW INSTL CODE (see fig. 4.1a) 1. NEW INSTL CODE NEW INST. CODE NEW MASTER CODE NEW INST. CODE INST. CODE xxxx [code] MASTER CODE xxxx [code] INST. CODE xxxx [code] (see fig. 4.1a) Note: Installer Code should never be programmed as â0000â. Doing so will lock the user out of the installer menu! Figure 4.1c - Setting a New Installer Code in System with Inst. & Master Inst. Codes (see note) 4.2 ENROLLING WIRELESS DEVICES AND KEYFOB TRANSMITTERS 4.2.1 General Guidance The ENROLLING mode has the following sub-modes: ⢠ENROLLING TYPE (wireless devices) ⢠ENROLL SENSORS. ⢠ENROLL KEYFOB (multi-button CodeSecure transmitters) ⢠ENROLL WL 1WAY KP (wireless commander MCM-140+) ⢠ENROLL WL 2WAY KP (wireless 2-way keypad MKP-150/ MKP-151) ⢠ENROLL WL SIREN (wireless siren) Before beginning, gather all the devices that you intend to enroll and make sure they all have batteries installed. Your control panel must recognize the unique identification code (ID) of each such device in order to supervise them, receive their signals and respond accordingly. Attention! CodeSecure transmitters are mainly used for arming/disarming and can not be enrolled to zones. In order to enroll to zones, use only non-CodeSecure wireless devices. 4.2.2 Enrolling Type Here you determine whether to enroll a wireless device by normal transmission or by device Tamper function (opening its cover). Options: normal, or by tamper. 4.2.4 Enroll/Delete Keyfob Transmitters Keyfob transmitters are multi-button wireless CodeSecure⢠transmitters. Eight system users use them for better, quicker and safer control over various system functions. To enroll / delete 1-way or 2-way keyfob transmitters, refer to figure 4.2. 4.2.5 Enroll/Delete Wireless Commander The Wireless Commander (MCM-140+) is a remote control unit that enables the user to remotely control the system. To enroll / delete up to 8 wireless commanders, refer to figure 4.2 (Enroll WL 1-way KP). 4.2.6 Enroll/Delete 2-Way Keypad The 2-way keypad, type MKP-150/MKP-151, enables the user to remotely control the system and also to receive data from the system (alarm and trouble data). To enroll up to two 2-way keypads, refer to figure 4.2. 4.2.7 Enroll/Delete Wireless Siren The wireless siren is a remote siren that is activated upon predefined events by the PowerMaxExpress system. To enroll / delete up to 2 wireless sirens, refer to figure 4.2. 4.2.3 Enroll/Delete Sensors Wired detector can be enrolled in zone 29 and wireless detectors can be enrolled in zones 01-28. ⢠Before enrolling, the lens at the front of PIR STOP and dual-technology sensors should be masked to prevent inadvertent transmission. ⢠Make sure that magnetic contact transmitter is together with its magnet, to prevent it from sending alarm transmission. To enroll / delete wired / wireless sensors, refer to Fig. 4.2. D-302017 (*) ENROLL SENSORS ENROLLING TYPE SET SENSITIV. normal enroll by tamper Keyfob No: - higher sensitivity lower sensitivity Select by or [Keyfob No.] (e.g. 5) (****) Keyfob No: 5 READY 00:00 Zone No. [wired 29/30] (e.g. 29) NORMAL MODE ZONE No: 05 USER SETTINGS INSTALLER MODE ENTER CODE [installer code] ZONE No: 05 TRANSMIT NOW [Initiate transmission) TO DELETE ZONE No: 29 ZONE No: 05 ZONE No: 05 for next enrolling action for next enrolling action Enrolling wired sensor Enrolling a WL Sensor TO DELETE 1way kp No: 5 No. 1 or 2] (e.g. 2) 2way kp No : 2 Partition ENROL WL 2WAY KP [MKP-150/151 (**) 1way kp No : 5 TRANSMIT NOW press key until red LED lights Enrolling a Keyfob 2way kp No: [WL 1-way keypad No. 1 to 8] (e.g. 5) 1way kp No : 5 Deleting a Keyfob Applies only for next Note: when in Partition mode enrolling action (*****) 1way kp No : 3. DEFINE ZONES Partition 1 KEYFOB No: 05 Deleting wired/ WL sensor ENROL WL 1WAY KP 2. ENROLLING KEYFOB No: 05 [select partition 1 - 4] (**) (***) 1. NEW INSTL CODE TO EXIT Partition (**) TO ENROLL TO DELETE (press any key) (**) [WL Zone No. [wired/WL Zone No. 01-28] (e.g. 05) 01-30] (e.g. 05) ZONE No: 29 (**) Keyfob No: 5 TRANSMIT NOW ZONE No: - (First display is READY or NOT READY) ENROLL KEYFOB TRANSMIT NOW Press MKP150/151 back tamper switch once (see MKP150/151 inst. instructions) 2way kp No: 2 for next enrolling action (**) 2way kp No : 2 TO DELETE AWAY 2way kp No: 2 Partition 1 Deleting a wireless Commander MCM-140+ [select partition 1 - 4] Enrolling a wireless keypad MKP-150/151 Deleting a wireless keypad MKP-150/151 1way kp No: 5 for next enrolling action Note: Applies only when in Partition mode Enrolling a wireless Commander MCM-140+ ENROL WL SIREN SIREN No : siren No. 1[WL or 2] (e.g. 2) siren No : 2 TRANSMIT NOW Momentarily press the wireless siren self-test button until a squawk is heard (1 sec. approx.) (**) siren No : 2 Open WL siren cover and remove its battery TO DELETE siren No: 2 for next enrolling action Enrolling a wireless siren siren No: 2 Deleting a wireless siren Figure 4.2 - Enrolling / Deleting Wireless Devices / Keyfobs / Wireless Commanders / Wireless Sirens *** Initiate either normal transmission or the device Keyfob enrolling can be performed by the installer or by tamper function (see ENROLLING TYPE, Par. 4.2.2). the user (via USER SETTINGS menu). **** Select "higher" sensitivity for far wireless device, ** A black box in the display means that a device is "lower" for near devices. enrolled (the system has learned its ID). No black box ***** MKP-150/151 is not compatible for use when partition indicates that the device is not enrolled. is enabled. 10 D-302017 4.3 DEFINING ZONE TYPES, NAMES, CHIME ZONES & PARTITION This mode allows you to assign one of 15 zone types to A list of factory defaults is printed in table 1. You may fill each of the system's 29 (wireless & wired) zones. In out the blank columns even before you start and proceed addition, it also allows you to assign a name to each zone to program according to your own list. and determine whether the zone will operate as a chime Remember! zone (only while the system is in the disarmed or Home A delay zone is also a perimeter zone by definition. arming state). When a chime zone is triggered, chime Zone types are fully explained in Appendix C. melody or zone name is heard (there are 2 selectable chime modes - Melody chime or Chime Off). Refer to Figure 4.1a to gain access to Selectable Zone Names USER SETTINGS 31 zone names can be selected, 26 fixed names and 5 menu custom names (defined by the installer - see chap. 4.9): Dining room Hall Utility room Attic Downstairs Kitchen Yard Back door Emergency Laundry room Custom 1 Basement Fire Living room Custom 2 Bathroom Front door Master bath Custom 3 Bedroom Master bdrm Custom 4 Child room Garage Garage door Office Custom 5 Closet Guest room Upstairs Den USER SETTINGS INSTALLER MODE ENTER CODE [installer code] 2. ENROLLING 3. DEFINE ZONES ZONE No: - [Zone No.] (e.g. 05) Zxx: TYPE - TO EXIT 1. Inter-follow 2. Perimeter 3. Perim-follow 4. Delay 1 5. Delay 2 6. 24h silent 7. 24h audible 8. Fire 9. Non-alarm 10. Emergency 11. Gas 12. Flood 13. Interior 14. Temperature 15. Home/Delay (*) OPTIONAL (**) Zxx: KEY ON/OFF z-key enable z-key disable (*) Attic Back door Basement Bathroom Bedroom Child room Closet (see list above) (*) (see note) Zxx: CHIME Melody-chime Chime off (*) Zxx: NAME - - Zxx: PARTITION Partition 1 Partition 2 Partition 3 Partition 4 (*) Figure 4.3 - DEFINE ZONES Flow Chart The currently saved option is displayed with a dark box at the right side. To review the options, repeatedly click I OK (a dark box will be displayed at the right side). button, until the desired option is displayed, then click or I OK button in this location brings you to the same zone number that you are dealing with. Press ** Clicking the to select the next zone. Table 1 - DEFAULT AND PROGRAMMED ZONE DEFINITIONS Zone Zone Type Zone Name Chime (melody No. Default Programmed Default Programmed Zone Name or Off) (*) 1 Delay 1 Front Door 2 Delay 1 Garage 3 Delay 2 Garage Door 4 Perimeter Back Door 5 Perimeter Child Room 6 Interior Office 7 Interior Dining Room 8 Perimeter Dining Room 9 Perimeter Kitchen D-302017 or 11 Zone Zone Type Zone Name Chime (melody No. Default Programmed Default Programmed Zone Name or Off) (*) 10 Perimeter Living Room 11 Interior Living Room 12 Interior Bedroom 13 Perimeter Bedroom 14 Perimeter Guest Room 15 Interior Master Bedroom 16 Perimeter Master Bedroom 17 Perimeter Laundry Room 18 Perimeter Master Bathroom 19 Perimeter Basement 20 Fire Fire 21 Fire Fire 22 Emergency Emergency 23 Emergency Emergency 24 24 h / silent Basement 25 24 h / silent Office 26 24 h / audible Attic 27 24 h / audible Den 28 non-alarm Yard 29 non-alarm Hall 30 non-alarm Utility room * Note: All zones are CHIME OFF by default. Enter your own choice in the last column and program accordingly. 4.4 DEFINING CONTROL PANEL PARAMETERS 4.4.1 Preliminary Guidance This mode allows you to customize the control panel and adapt its characteristics and behavior to the requirements of the particular user. An illustrated process is shown in Figure 4.4. In this illustration, each selected option is displayed with a dark box at the right side. To review the button, until or options, repeatedly click the desired option is displayed, then click SHOW/OK button. 4.4.2 Entry Delays 1&2 (Fig. 4.4, location 01, 02). Two different entry delays allow the user to enter the protected site (while the system is in the armed state) via 2 specific doors and routes without causing an alarm. Following entry, the user must disarm the control panel before the entry delay expires. Slow-rate warning beeps start sounding once the door is opened, until the last 10 seconds of the delay, during which the beeping rate increases. Locations No. 1 (entry delay 1) and 2 (entry delay 2) allow you to program the length of these delays. Available options for each delay are: 00s, 15s, 30s, 45s, 60s, 3m and 4m. 4.4.3 Exit Delay (Fig. 4.4 location 03). An exit delay allows the user to arm the system and leave the protected site via specific routes and doors without causing an alarm. Slow-rate warning beeps start sounding once the arming command has been given, until the last 10 seconds of the delay, during which the beeping rate increases. Location No. 3 allows programming of the exit delay length. Available options are: 30s, 60s, 90s, 120s, 3m, and 4m. 4.4.4 Bell Time (Fig. 4.4, location 04). Here you select the length of time the bell (or siren) is allowed to function upon alarm. The bell time starts upon activation of the siren. Once the bell time expires, the siren is automatically shut down. Available options are: 1, 3, 4, 8, 10, 15 and 20 minutes. Note: Bell Time is defined for the entire alarm system. 12 However, when disarming any partition (in a PowerMaxExpress Partition system) the siren ceases to sound. 4.4.5 Abort Time (Fig. 4.4 location 05). Here you select the length of time allowed by the system to abort an alarm (not applicable to alarms from FIRE, 24H SILENT, EMERGENCY, GAS, FLOOD and TEMPERATURE zones). The PowerMaxExpress is programmed to provide an âabort intervalâ that starts upon detection of an event. During this interval, the buzzer sounds a warning but the siren remains inactive and the alarm is not reported. If the user disarms the system within the allowed abort interval, the alarm is aborted. Available options are: 00s, 15s, 30s, 45s, 60s, 2m, 3m and 4m. 4.4.6 Alarm Cancel (Fig. 4.4, location 06). Here you determine the âcancel alarmâ period that starts upon reporting an alarm to the central station. If the user disarms the system within that time period, a âcancel alarmâ message is sent to the central station. Available options are: 1, 5, 15, 60 minutes, 4 hours and also cancel inactive. 4.4.7 Quick Arm (Fig. 4.4, location 07). Here you determine whether the user will be allowed to perform quick arming or not. Once quick arming is permitted, the control panel does not request a user code before it arms the system. The two options are: quick arm ON and quick arm OFF. 4.4.8 Bypass (Fig. 4.4, location 08). Here you permit either manual bypassing of individual zones (through the USER SETTINGS menu), or allow the system to "force arm" (perform automatic bypassing) of open zones during the exit delay. If desired, press the arming key again if you want to eliminate the protest tone that sounds during forced arming. If a zone is open and forced arming is not D-302017 permitted, âNOT READYâ is displayed and the system does not arm (the âSad Melodyâ will sound). If "no bypass" is selected, neither manual bypassing nor force arming is allowed. Options: manual bypass, force arm and no bypass. 4.4.9 Exit Mode (Fig. 4.4, location 09). Here you determine exit mode options. Three types of exit modes are available: Restart Exit - Exit delay restarts when the door is reopened during exit delay. The restart occurs once only. Restarting the exit delay is helpful if the user re-enters immediately after going out to retrieve an item that he left behind. Off by door - When the door is closed, the exit delay is automatically terminated (even if the defined exit delay was not completed). Normal - The exit delay is exactly as defined, regardless of whether the door is open or closed. 4.4.10 Piezo Beeps (Fig. 4.4, location 10). Here you determine whether warning beeps will sound or muted during exit and entry delays. An additional option is to mute the warning beeps only when the system is armed âHOMEâ. Options: enable beeps, off when home and disable beeps. 4.4.11 Trouble Beeps (Fig. 4.4, location 11). Under trouble conditions, the sounder emits a series of 3 short beeps once per minute. Here you determine whether this special beeping sequence will be active, inactive, or just inactive at night (the range of ânightâ hours is defined in the factory). The 3 options are: enable beeps, off at night (8 PM through 7 AM) and disable beeps. 4.4.12 Panic Alarm (Fig. 4.4, location 12). Here you determine whether the user will be allowed to initiate a panic alarm by simultaneous pressing either the two panic buttons (on the keypad / wireless commander) or away + home (on a keyfob transmitter). Audible panic activates the siren and simultaneously transmits a message via telephone. Silent panic only transmits a message via telephone. The options are: silent panic, audible panic and disable panic. 4.4.13 Swinger Stop (Fig. 4.4, location 13). Here you determine the number of times each zone is allowed to initiate an alarm within a single arming period (including tamper & power failure events of detectors, PowerMaxExpress, wireless siren, etc.). If the alarms number from a specific zone exceeds the programmed number, the control panel automatically bypasses the zone to prevent recurrent siren noise and nuisance reporting to the central station. The zone will be reactivated upon disarming, or 48 hours after having been bypassed (if the system remains armed). Available options are: shut after 1, shut after 2, shut after 3 and no shutdown. Note: Swinger Stop is defined for the entire alarm system and not per partition (in a PowerMaxExpress Partition system). D-302017 4.4.14 Cross Zoning (Fig. 4.4, location 14). Here you determine whether cross zoning will be active or inactive. Cross zoning is a method used to counteract false alarms - an alarm will not be initiated unless two adjacent zones are violated within a 30-second time limit. This feature is active only when arming AWAY and only with zone couples from zone No. 18 to 27 (18 and 19, 20 and 21, etc.). You may use any one of these zone couples to create a âcross-zonedâ area. Note: If one of two crossed zones is bypassed (see Para. 4.4.8), the remaining zone will function independently. Note: Every 2 crossed zones must be of the allowed zone type (Interior, Perimeter, Perimeter follower). The options are: cross zone ON and cross zone OFF. Cross zoning is not applicable in Entry/ Exit zones and 24h zones (Fire, Emergency, 24h audible, 24h silent). 4.4.15 Supervision (Fig. 4.4, location 15). Here you determine the time limit for reception of supervision reports from various supervised wireless devices. If any device does not report at least once within the selected time limit, an âINACTIVITYâ alert is initiated. The options are: 1, 2, 4, 8, 12 hours and disable. 4.4.16 NOT READY (Fig. 4.4, location 16). Here you determine if the system will be in NOT READY status when there is a supervision failure. In the "in supervision" mode, the system will be in NOT READY status if during the last 20 minutes a supervision message was not received. Options: normal and in supervision. Note: NOT READY operates only per partition (in a PowerMaxExpress Partition system). 4.4.17 AUX Button A (Fig. 4.4, location 17). Here you select the function of the AUX button/ button A on keyfob transmitters MCT-234, MCT-237 and wireless commanders MCM-140+. Four options are offered for each AUX button: Instant: Pressing the AUX button while the exit delay is in progress will cause the system to arm âinstantâ (the entry delay is canceled). Skip exit delay: Pressing the AUX button will immediately cause the system to arm immediately. 4.4.18 AUX Button B 2-W-KF (Fig. 4.4, loc. 18). Applicable only for 2-way keyfob MCT-237. Same as 4.4.17 but for AUX button B. 4.4.19 Jam Detect (Fig. 4.4, location 19). Here you determine whether jamming (interfering transmissions, on the radio channel used by the system) will be detected and reported or not. If a jam detection option is selected, the system does not allow arming under the relevant jamming conditions. Jam Detection Options Option Detection and Reporting when UL (20/20) There is continuous 20 seconds of (USA standard) jamming EN (30/60) There is an accumulated 30 seconds of (Europe standard) jamming within 60 sec. class 6 (30/60) Like EN (30/60) but the event will be (British standard) reported only if the jamming duration exceeds 5 minutes. Disabled (No jamming detection and reporting). 13 4.4.20 Latchkey (Fig. 4.4, location 20). Here you determine whether the system can be armed in the latchkey mode. If the system is armed this way, a âlatchkeyâ message will be sent to specific telephones upon disarming by a âlatchkey userâ (users 5-8 or keyfob transmitters 5-8). This mode is useful when parents at work want to be informed of a childâs return from school. You can record a name for latchkey users. The options are: Latchkey ON and Latchkey OFF. 4.4.21 âNot Activeâ (Fig. 4.4, location 21). Here you determine the time limit for reception of signals from sensors used to monitor the activity of sick, elderly or disabled people. If no sensor detects and reports movement at least once within the defined time limit, a ânot-activeâ alert is initiated. Options: 3, 6, 12, 24, 48, 72 hours and no act disable. Note: The Not Active timer is defined for the entire alarm system for the above hour options and not per partition (in a PowerMaxExpress Partition system). Subsequently, a dedicated timer is assigned to each partition. 4.4.23 Duress (Fig. 4.4, loc. 23). A duress alarm (ambush) message can be sent to the central station if the user is forced to disarm the system under violence or menace. To initiate a duress message, the user must disarm the system with the duress code (2580 by default). Here you can change the code digits or enter "0000" to disable the duress feature. The system does not allow the user to program the duress code saved in this memory location as an existing user code. 4.4.24 Piezo Siren (Fig. 4.4, location 24). Here you determine whether the internal siren will sound or remain silent upon alarm (according to the user preference). Options: piezo siren on, piezo siren off. 4.4.25 Reset Option (Fig. 4.4, location 25). (Not applicable in the USA) Here you determine whether the system can be rearmed (after an event) by the user or only by the installer. Options: user reset or engineer reset. If Engineer Reset is selected, the system can be rearmed only by the installer; by entering and exiting the installer menu, by entering and exiting the event log (see section 7), or by remote telephone. To perform Engineer Reset via the telephone, establish communication with the PowerMaxExpress (see user guide, par. 6.3A, steps 1-5) and continue as follows: a. [*], [installer code], [#] b. Wait for 2 beeps c. [*], [1], [#] d. [*], [99], [#] Note: This menu is not available when partition is enabled. 4.4.26 Tamper Option (Fig. 4.4, location 26). Here you determine whether zone tamper will be reported or ignored. Available options are: zone tamper ON and zone tamper OFF. 4.4.27 Siren On Line (Fig. 4.4, location 27). Here you determine whether the siren will be activated or not when the telephone line fails during system armed state. Available options are: enable on fail, disable on fail. 14 4.4.28 Memory Prompt (Fig. 4.4, location 28). Here you determine whether the user will receive indication that an alarm has been activated. Available options are: enable and disable. 4.4.29 Disarm Option (Fig. 4.4, location 29). Here you determine when it is possible to disarm the system: A. Any time. B. In AWAY mode, during entry delay, by using the PowerMaxExpress keypad or wireless sensor (keyfob). C. In AWAY mode, during entry delay, by using a wireless device (keyfob) only (this is set as a default in UK to comply with DD243). D. During entry delay, or by using the PowerMaxExpress keypad in AWAY mode. Options: any time, on entry all, on entry wireless, or entry + away kp. 4.4.30 Bell/Rep. Option (Fig. 4.4, location 30). Here you determine whether an alarm will be initiated (siren / report) when there is a supervision / jamming failure during AWAY arming state. Available options are: EN standard and other. When "EN standard" is selected, if there is supervision / jamming failure during AWAY arming, the siren is activated and the events are reported as tamper events. When "Other" is selected, there is no such activity during AWAY arming. 4.4.31 Low-Bat Ack (Fig. 4.4, location 31). Here you determine whether the user will hear or will not hear low battery sound when he tries to disarm the system with a keyfob whose battery voltage is low. Available options are: keyfob L-B on (the user has to acknowledge the keyfob low battery message) or keyfob L-B off (the user does not have to acknowledge the keyfob low battery message). 4.4.32 Screen Saver (Fig. 4.4, location 32). Here you can determine that if no key is pressed during more than 30 seconds, the display will be âPowerMaxâ (to prevent possible intruder of knowing the system status). You can determine that normal display will return after pressing the button followed by entering user code (Refresh by Code) or after pressing any key (Refresh by Key). If Refresh by Key is selected, the first pressing of any key (except Fire and Emergency) will cause normal display return and the second press will perform the key function. Regarding the Fire and Emergency keys, the first key press will cause normal display return and also will perform the Fire/Emergency function. Options: scrn saver OFF, refresh by code, refresh by key. 4.4.33 Confirm Alarm (Fig. 4.4, location 33). Here you determine that if 2 successive alarms will occur during a specific period, the second alarm will be considered as a confirmed alarm (for confirmed alarm reporting, (see par. 4.5.3). Options: disable 30 min., 45 min., 60 min., or 90 min. 4.4.34 AC FAIL REP (Fig. 4.4, location 34). Here you determine the time interval between AC power failure occurrence and the failure reporting. Options: 5 minutes, 30 minutes, 60 minutes or 180 minutes. D-302017 4.4.36 User Permission (Fig. 4.4, location 36). Here you determine whether the access to the INSTALLER MODE requires user permission. If you select ENABLE, the installer mode will be accessible only through the user menu after entering the user code. Options: Enable, Disable. Note: This menu is not available when partition is enabled. D-302017 4.4.39 Key Zones Options (Optional) (Fig. 4.4, location 39). Here you determine whether or not the system can be armed and disarmed by zones 21-18, 29 or 21-29, provided that for these zones "non-alarm type" and "z-key enable" was predefined (see par. 4.3). Key zones can be wireless or wired zones. When using wireless key zones, only the MCT-100 and MCT-102 transmitters are used. The left pushbutton on the MCT-102 transmitter or input 1 of the MCT-100 transmitter is used for arming in AWAY mode. The right pushbutton on the MCT-102 transmitter or input 2 of the MCT-100 transmitter is used for disarming. When using wired key zones, the control panel toggles between AWAY mode and Disarm. Note: In "Singapore" versions of the PowerMaxExpress, an open circuit arms the alarm system in AWAY mode and a closed circuit changes the state of the alarm system from AWAY mode to Disarm. IMPORTANT! Enrolment of the MCT-100 or MCT-102 transmitter must be performed via the left pushbutton on the MCT-102 transmitter or input 1 of the MCT-100 transmitter. Caution! Arming the system using a transmitter assigned to zones 21 and 28, or via wired zone 29 compromises security. This function is, therefore, only available in specific PowerMaxExpress versions according to the customer's request. Options: disable option, z. 21-28 enable, z. 29 enable, or z. 21-29 enable. 15 Refer to Figure 4.1a to gain access to USER SETTINGS menu 01: ENTRY DELAY 1 02: ENTRY DELAY 2 entry dly2 00 s entry dly2 15 s entry dly2 30 s entry dly2 45 s entry dly2 60 s entry dly2 3 m entry dly2 4 m entry dly1 00 s entry dly1 15 s entry dly1 30 s entry dly1 45 s entry dly1 60 s entry dly1 3 m entry dly1 4 m USER SETTINGS INSTALLER MODE 03: EXIT DELAY 04: BELL TIME exit delay 30 s exit delay 60 s exit delay 90 s exit delay 120 s exit delay 3 m exit delay 4 m bell time 1 m bell time 3 m bell time 4 m bell time 8 m bell time 10 m bell time 15 m bell time 20 m ENTER CODE [installer code] 05: ABORT TIME 1. NEW INSTL CODE 06: ALARM CANCEL abort time 00 s abort time 15 s abort time 30 s abort time 45 s abort time 60 s abort time 2 m abort time 3 m abort time 4 m 2. ENROLLING 3. DEFINE ZONES 4. DEFINE PANEL 5. DEFINE COMM cancel time 1 m cancel time 5 m cancel time 15 m cancel time 60 m cancel time 4 h cancel inactive 09: EXIT MODE TO EXIT Note: The currently saved options are displayed with dark box at the right side of the display. To review the options, repeatedly click or until the desired option is displayed, then click OK (a dark box will be displayed at the right side). restart exit off by door normal enable beeps off when home disable beeps 13: SWINGER STOP 14: CROSS ZONING shut after 1 shut after 2 shut after 3 no shutdown cross zone ON cross zone OFF in USA 17: AUX BUTTON A 18: AUX B 2-W-KF instant skip exit delay instant skip exit delay manual bypass no bypass force arm Note: Force arm is not applicable to the UK. in USA 11: TROUBLE BEEPS in USA disable beeps enable beeps off at night 12: PANIC ALARM in USA 15: SUPERVISION superv time 1 h superv time 2 h superv time 4 h superv time 8 h superv time 12 h disable 19: JAM DETECT UL (20/20) EN (30/60) class 6 (30/60) disable 23: DURESS 21: NOT ACTIVE no act time 3 h no act time 6 h no act time 12 h no act time 24 h no act time 48 h no act time 72 h no act disable duress code 2580 (Change the code or enter 0000 to disable duress function) silent panic audible panic disable panic 16: NOT READY normal in supervision 20:LATCHKEY latchkey on latchkey off 24: PIEZO SIREN piezo siren on piezo siren off Note: Duress code is not applicable to the UK. 25: RESET OPTION 26: TAMPER OPTION user reset enginner reset Not applicable in the USA 08: BYPASS quick arm ON quick arm OFF 10: PIEZO BEEPS Note: Swinger Stop is defined for entire alarm system. Not applicable in the USA 07: QUICK ARM zone tamper on zone tamper off 27: SIREN ON LINE enable on fail disable on fail 28:MEMORY PROMPT enable disable 29: DISARM OPTION 30: BELL/REP. OPT 31: LOW-BAT ACK 32: SCREEN SAVER any time on entry wireless entry + awake kp on entry all EN standard other keyfob L-B on keyfob L-B off scrn saver OFF refresh by code refresh by key in UK 33: CONFIRM TIME 34: AC FAIL REP 36: USER PERMIT disable 30 minutes 45 minutes 60 minutes 90 minutes 5 minutes 30 minutes 60 minutes 180 minutes disable enable 39: KEY ZONES OPT disable option z. 21-28 enable in z. 29 enable UK z. 21-29 enable Figure 4.4 - DEFINE PANEL Flow Chart 16 D-302017 4.5 DEFINING COMMUNICATION PARAMETERS Preliminary Guidance This mode allows you to adapt the telephone communication parameters to the local requirements. Compatible central station receivers are: Osborne-Hoffman model 2000, Ademco Model 685, FBII Model CP220, Radionics Model D6500, Sur-Gard Model SG-MLR2-DG and Silent Knight Model 9500. IMPORTANT: In telephone / pager number locations and account number locations, you may be required to enter hexadecimal digits. In telephone number locations, these digits are used as codes to control the dialer: Hex. Keying Code Digit Sequence Significance A <#> â <0> Applicable only at the beginning of a number - the dialer waits 10 seconds or waits for dial tone, whichever comes first and then dials. D <#> â <3> Applicable only at the beginning of a number - the dialer waits 5 seconds for dial tone and goes on hook if none is received. E <#> â <4> Applicable only in the middle of the number - the dialer waits 5 seconds F <#> â <5> Not applicable in phone numbers Note: A "+" can be entered at the beginning of the line by and then pressing To enter a series of digits, use the following keys: - to enter the number - moves the cursor from left to right GPRS Report [Fig 4.5.2(1)] Here you determine whether the alarm system will report events to the central station via the GPRS channel. The options are: disable and enable. GSM Report [Fig 4.5.2(2)] Here you determine whether the alarm system will report events to the central station via the GSM voice channel. The options are: disable and enable. SMS Report [Fig 4.5.2(3)] Here you determine whether the alarm system will report events to the central station via the SMS channel. The options are: disable and enable. GPRS APN [Fig 4.5.2(4)] Here you enter the name of the APN (Access Point) used for the internet settings for the GPRS (up to 40 digits). GPRS Username [Fig 4.5.2(5)] Here you enter the username of the APN used for GPRS communications (up to 30 digits). GPRS Password [Fig 4.5.2(6)] Here you enter the password of the APN used for GPRS communications (up to 16 digits). The following table provides a list of the keys used by the PowerMaxExpress editor for the GPRS APN, GPRS Username, GPRS Password menus and Custom Zone Name option. Key Functionality Moves the cursor from left to right. Long press for speed. - moves the cursor from right to left Moves the cursor from right to left. - deletes everything after the cursor (to the right) Long press for speed. Scrolls upward the sequence of inserted digits. 4.5.1 PSTN / GSM (Fig. 4.5 Detail A) Area Code [Fig 4.5.1(1)] Here you enter the system tel. area code (up to 4 digits). Line Prefix [Fig 4.5.1(2)] Here you enter the number that is used as a prefix to access an outside telephone line (if exists). Dial Method [Fig 4.5.1(3)] Here you determine the dialing method used by the automatic dialer built into the PowerMaxExpress control panel. The options are: Pulse and tone (dtmf). GSM Keep Alive [Fig 4.5.1(4)] Here you prevent the GSM service provider from disconnecting the GSM line if the user has not initiated any outgoing telephone calls during the last 28 days. The options are: disable and every 28 days. 4.5.2 GPRS / BB [Fig. 4.5 Detail B] The GSM/GPRS module is capable of communicating with the Central Station receiver by GPRS, GSM Voice and SMS channels. Each of the channels can be separately enabled or disabled in order to allow or prohibit the module from using it for the event reporting. If all channels are enabled, the GSM/GPRS module will always try GPRS first. If fails, it will try GSM Voice. If fails, it will try any other possible method (PSTN, Broadband) and only then it will try SMS. This is due to the fact that SMS is the most unreliable option of communication. Disabling any of the GSM Module channels will cause the module to use a different sequence than the one described above. D-302017 Long press for speed. Scrolls downward the sequence of inserted digits. Long press for speed. Places cursor to extreme right position of edit string and shows the last 16 digits of edit string. Reverts to previous or top menu without saving the edit string. Reverts to " TO EXIT" without saving the edit string. I OK Saves and reverts to previous menu. Clears all digits to the right of cursor. Clears one digit by cursor. Selects between uppercase or lowercase digits. PIN Code [Fig 4.5.2(8)] Enter PIN code of the SIM card installed in the PowerMaxExpress unit (up to 16 digits). Force Home Network [Fig 4.5.2(9)] Here you determine whether to force the SIM card to use the home network only and not to select another network in case the home network cannot be found. The options are: disable and enable. 17 4.5.3 C.S. Reporting (Fig. 4.5 Detail C) Report Events [Fig 4.5.3(1)] â see note in Fig. 4.5 Detail C Here you determine which types of event will be reported to central stations. Due to lack of space in the display, abbreviations are used: alarm is âalrmâ, alert is âalrtâ and open/close is âo/câ. The asterisk (J) is a separator between events reported to central station 1 and events reported to central station 2. Messages are divided by type into four groups: No. Group Alarms Open/close Events Reported Fire, Burglary, Panic, Tamper Arming AWAY, Arming HOME, Disarming Alerts No-activity, Emergency, Latchkey, Gas, Flood, Temperature Maintenance Low-battery AC failure "Alarm" group has the highest priority and "Alert" group has the lowest priority. The selectable options are as follows: Plan name all -o/c J backup Sent to center 1 Sent to center 2 All but open/close All but open/close if center 1 doesnât respond all J all All All all-o/c J all -o/c All but open/close All but open/close all âo/c J o/c All but open/close Open/close all (âalrt) J alrt All but alerts Alerts Alrm J all (âalrm) Alarms All but alarms Disable report Nothing Nothing all J backup All All if cent. 1 doesnât respond Note: âAllâ means that all 4 groups are reported and also trouble messages - sensor / system low battery, sensor inactivity, power failure, jamming, communication failure etc. 1st Report Method [Fig 4.5.3(2)] Here you define the 1st priority of method used to report events. The options are: disable, cellular and PSTN. 2nd Report Method [Fig 4.5.3(3)] Here you define the 2nd priority of method used to report events. If the method defined to report events in the 1st priority fails, the control panel will attempt to report using the method defined in the 2nd priority (see notes in 1st Report Method). The options are: disable, cellular and PSTN. 3rd Report Method [Fig 4.5.3(4)] Here you define the 3rd priority of method used to report events. If the method defined to report events in the 2nd priority fails, the control panel will attempt to report using the method defined in the 3rd priority (see notes in 1st Report Method). The options are: disable, cellular and PSTN. Dual Reporting [Fig 4.5.3(5)] Here you determine whether to report events using PSTN and cellular at the same time instead of waiting for the 1st method to fail before trying the 2nd method. The options are: disable and PSTN & cellular. Receiver 1 Account No. [Fig 4.5.3(6)] - see note in Fig. 4.5 Detail C Here you enter the number that will identify your specific alarm control system to the 1st central station. The number consists of 6 hexadecimal digits. Receiver 2 Account No. [Fig 4.5.3(7)] - see note in Fig. 4.5 Detail C Here you enter the number that will identify your system to the 2nd central station. The account number consists of 6 hexadecimal digits. 18 PSTN/GSM RCVR1 [Fig 4.5.3(8)] - see note in Fig. 4.5 Detail C Here you program telephone number of the 1st central station (including area code, 16 digit max) to which the system will report the event groups defined in Report Events. PSTN/GSM RCVR2 [Fig 4.5.3(9)] - see note in Fig. 4.5 Detail C Here you program telephone number of the 2nd central station (including area code, 16 digit max) to which the system will report the event groups defined in Report Events. IP RCVR 1 [Fig 4.5.3(10)] Here you enter the IP address of the IP receiver that is located in the 1st central station. IP RCVR 2 [Fig 4.5.3(11)] Here you enter the IP address of the IP receiver that is located in the 2nd central station. SMS RCVR 1 [Fig 4.5.3(12)] Here you enter the telephone number of the SMS receiver that is located in the 1st central station. SMS RCVR 2 [Fig 4.5.3(13)] Here you enter the telephone number of the SMS receiver that is located in the 2nd central station. PSTN Report Format [Fig 4.5.3(14)] - see note in Fig. 4.5 Detail C Here you select the reporting format used by the control panel to report events to central stations. The options are: SIA text Contact-ID SIA 4/2 1900/1400 4/2 1800/2300 Scancom (see Appendix B - code lists). 4/2 Pulse Rate [Fig 4.5.3(15)] - see note in Fig. 4.5 Detail Here you select the pulse rate at which data will be sent to central stations if any one of the 4/2 formats has been selected in PSTN Report Format. The options are: 10, 20, 33 and 40 pps. PSTN Report Retry [Fig 4.5.3(16)] - see note in Fig. 4.5 Detail C Here you determine the number of times the communicator will dial the central stationâs number via PSTN. The options are: 2, 4, 8, 12 and 16 attempts. GSM Report Retry [Fig 4.5.3(17)] - see note in Fig. 4.5 Detail C Here you determine the number of times the communicator will try to report via a cellular group (GPRS, GSM and SMS) to the central station. The options are: 2, 4, 8, 12 and 16 attempts. Auto Test Time [Fig 4.5.3(18)] Here you determine the time at which the telephone line will be tested and reported to the central station. Auto Test Cycle [Fig 4.5.3(19)] Here you determine the time interval between consecutive telephone line test messages sent to the central station. The control panel performs this at regular intervals to verify proper communications. The options are: test every 5 hours, test every 1, 2, 5, 7, 14, 30 days and test OFF. Line Fail Report [Fig 4.5.3(20)] PSTN [Fig 4.5.3(20a)] Here you determine if the PSTN telephone line disconnection will be reported or not and determine the delay between detection of line disconnection and the failure reporting. If the telephone line is disconnected, the message "tel line fail" will be stored in the event log. The options are: don't report, immediately, 5 minutes, 30 minutes, 60 minutes or 180 minutes. D-302017 GSM/GPRS [Fig 4.5.3(20b)] Here you determine if the GSM/GPRS line disconnection will be reported or not and determine the delay between detection of line disconnection and report failure. If the telephone line is disconnected, the message "GSM line fail" will be stored in the event log. The options are: don't report, 2 minutes, 5 minutes, 15 minutes, or 30 minutes. PSTN Up / Down [Fig 4.5.3(21)] Remote Access [Fig 4.5.3(21a)] Here you give or deny permission to access the system and exercise control from a remote telephone. The options are: rem. access ON and rem. access OFF. Mast. Downl Code [Fig 4.5.3(21b)] Here you determine the master installer 4-digit password for downloading/uploading data into/from the PowerMaxExpress memory. Attention! If "0000" is used, it will not enable connection of the PowerMaxExpress to the PC for upload/download purpose. Inst. Downl Code [Fig 4.5.3(21c)] Here you determine the installer 4-digit password for downloading data into the PowerMaxExpress memory. Attention! If "0000" is used, it will not enable connection of the PowerMaxExpress to the PC for upload/download purpose. Upload Option [Fig 4.5.3(21d)] Here you determine whether the PowerMaxExpress data can be uploaded into a computer while the system is in disarm state or at any time (in HOME/AWAY arming & disarm state). The options are: when system OFF and any time Up Download Tel# [Fig 4.5.3(21e)] Here you enter the telephone number (up to 16 digits) of the UL/DL server. Note: Only for use with control panels monitored by compatible central stations. Leave empty if not used. GPRS Up / Down [Fig 4.5.3(22)] My SIM Tel. # [Fig 4.5.3(22a)] Here you enter the PowerMax SIM card telephone number. The central station dials this number when it needs to connect to the PowerMaxExpress for uploading / downloading data. 1st Caller ID# [Fig 4.5.3(22b)] Here you determine the 1st VDNS receiver telephone number. When the PowerMaxExpress responds to an incoming call from the telephone number defined here, it creates a connection to the VDNS for uploading / downloading data. Note: Caller ID#1 / ID#2 should be 6 or more digits for wake-up by VDNS to work. 2nd Caller ID# [Fig 4.5.3(22c)] Here you determine the 2nd VDNS receiver telephone number. When the PowerMaxExpress responds to an incoming call from the telephone number defined here, it creates a connection to that VDNS for uploading / downloading data. Report Cnfrm Alarm [Fig 4.5.3(24)] - see note in Fig. 4.5 Detail C Here you determine whether the system will report whenever 2 or more events (confirmed alarm) occur during a specific period (see par. 4.4.33). Available options are: enable report, disable report, enable + bypass (enabling report and bypassing the detector - applicable to PowerMaxExpress that is compatible with DD243 standard). Report 24H Zones [Fig 4.5.3(25)] D-302017 Here you determine whether 24 hour (silent and audible) zones will function as normal 24 hour zones or as panic zones. The options are: both original, audible as panic, silent as panic, or both as panic. Recent Close [Fig 4.5.3(26)] Here you enable or disable the ârecent closingâ report, that is sent to the central station if an alarm occurs within 2 minutes from the expiry of the exit delay. The options are: recent close ON and recent close OFF. Zone restore [Fig 4.5.3(27)] Here you determine whether a zone restore will be reported or not. The options are: report restore and don't report. System Inactivity Report [Fig 4.5.3(28)] Here you determine whether the central station will receive a message if the system is inactive (not armed) during a defined period (days). The options are: disable, rep. after 7d, rep. after 14d, rep. after 30d, rep. after 90d. 4.5.4 Private Report (Fig. 4.5 Detail D) Report To Private [Fig 4.5.4(1)] Here you determine which event groups will be reported to private telephone subscribers. The options are as follows: ⢠Alarms + alerts ⢠Alarms ⢠Alerts ⢠Disable report The following siren signal will be sent to private telephone upon event reporting: FIRE: ON - ON - ON - pause.... (- - - - - - ......). ...) BURGLAR: ON continuously ( EMERGENCY: 2-tone siren; like an ambulance. Voice report [Fig 4.5.4(2)] 1st Private Tel# [Fig 4.5.4(2a)] Here you program the 1st telephone number (including area code, if required) of the private subscriber to which the system will report the event groups defined in Report To Private. 2nd Private Tel# [Fig 4.5.4(2b)] Here you program the 2nd telephone number (including area code, if required) of the private subscriber to which the system will report the event groups defined in Report To Private. 3rd Private Tel# [Fig 4.5.4(2c)] Here you program the 3rd telephone number (including area code, if required) of the private subscriber to which the system will report the event groups defined in Report To Private. 4th Private Tel# [Fig 4.5.4(2d)] Here you program the 4th telephone number (including area code, if required) of the private subscriber to which the system will report the event groups defined in Report To Private. Redial Attempts [Fig 4.5.4(2e)] Here you determine the number of times the communicator will dial the called partyâs number (private telephone). The options are: 1, 2, 3 and 4 attempts. Attention! A maximum of 2 dialing attempts is permitted by the Australian Telecommunication Authority. Tel. acknowledge [Fig 4.5.4(2g)] Here you determine whether the system will use the single acknowledge or the all acknowledge mode when reporting to private telephones. 19 Here you define the second SMS phone number (including area code, 16 digits maximum) to which pre-selected event types (see par. 4.6.3) will be reported. 3rd SMS Tel# [Fig 4.5.4(3c)] Here you define the third SMS phone number (including area code, 16 digits maximum) to which pre-selected event types (see par. 4.6.3) will be reported. 4th SMS Tel# [Fig 4.5.4(3d)] Here you define the fourth SMS phone number (including area code, 16 digits maximum) to which pre-selected event types (see par. 4.6.3) will be reported. Note: In the single acknowledge mode, receiving an acknowledge signal from a single telephone is sufficient to consider the current event closed and call off the communication session. The remaining telephones serve for backup purposes only. In the all acknowledge mode, an acknowledge signal must be received from each telephone before the current event is considered reported. The options are: single ack and all ack. SMS Report Tel# [Fig 4.5.4(3)] 1st SMS Tel# [Fig 4.5.4(3a)] Here you define the first SMS phone number (including area code, 16 digits maximum) to which pre-selected event types (see par. 4.6.3) will be reported. 2nd SMS Tel# [Fig 4.5.4(3b)] Refer to Figure 4.1a to gain access to USER SETTINGS menu USER SETTING INSTALLER MODE ENTER CODE [installer code] 1. NEW INSTL CODE 2. ENROLLING 3. DEFINE ZONES 4. DEFINE PANEL 1: PSTN / GSM see detail A 2: GPRS / BB see detail B 3: C.S. REPORTING see detail C 4: PRIVATE REPORT see detail D 5. DEFINE COMM. TO EXIT Figure 4.5 â Defining Communications FIGURE 4.5 - DETAIL A Note The currently saved options are displayed with dark box at the right side of the display. To review the options, repeatedly click or until the desired option is displayed, then click OK (a dark box will be displayed at the right side). 1: PSTN / GSM 4.5.1(1) AREA CODE xxxx Par. 4.5.1(2) Par. 4.5.1(3) LINE PREFIX DIAL METHOD xxxx (Enter tel. area code) (Enter prefix) tone (dtmf) pulse Par. 4.5.1(4) GSM KEEP ALIVE disable every 28 days FIGURE 4.5 - DETAIL B 2: GPRS/BB Note The currently saved options are displayed with dark box at the right side of the display. To review the options, repeatedly click or until the desired option is displayed, then click OK (a dark box will be displayed at the right side). 4.5.2(1) GPRS REPORT disable enable Par. 4.5.2(3) Par. 4.5.2(4) SMS REPORT GPRS APN disable enable Par. 4.5.2(5) Par. 4.5.2(6) GPRS USERNAME GPRS PASSWORD xxxx...(up to 30 digits) (Enter GPRS username) 20 Par. 4.5.2(2) GSM REPORT xxxx...(up to 16 digits) (Enter GPRS password) disable enable Par. 4.5.2(8) SIM PIN CODE xxxx...(up to 16 digits) (Enter SIM card PIN code) xxxx...(up to 40 digits) (Enter name of APN) Par. 4.5.2(9) FORCE HOME NETW. disable enable D-302017 FIGURE 4.5 - DETAIL C Note For Control Panel that has installer code & master installer code, the following functions are available only if the M ASTER INSTA LLE R code is entered: PSTN/GSM RCVR1 RCVR 1 ACCOUNT# RCVR 2 ACCOUNT# PSTN RPRT FORMAT 4/2 PLS RATE REPORT EVENTS GSM RPRT RETRY MAST. DL CODE 3:C.S. REPORTING 4.5.3(1) REPORT EVENTS all - o/c * backup all * all all - o/c * all - o/c all - o/c * o/c all (-alrt) * alrt alrm * all (-alrm) disable report all * backup Par. 4.5.3(5) DUAL REPORTING Note The currently saved options are displayed with dark box at the right side of the display. To review the options, repeatedly click or until the desired option is displayed, then click OK (a dark box will be displayed at the right side). disable PSTN & cellular Par. 4.5.3(9) PSTN/GSM RCVR2 (Enter Tel. No.) Par. 4.5.3(13) SMS RCVR 2 (Enter Tel. No.) Par. 4.5.3(17) D-302017 Par. 4.5.3(2) Par. 4.5.3(3) Par. 4.5.3(4) 1st RPRT METHOD 2nd RPRT METHOD 3rd RPRT METHOD disable cellular PSTN disable cellular PSTN disable cellular PSTN Par. 4.5.3(6) Par. 4.5.3(7) Par. 4.5.3(8) RCVR 1 ACCOUNT# RCVR 2 ACCOUNT# PSTN/GSM RCVR1 1st acc. no. (Enter RCVR 1 account No.) 2nd acc. no. (Enter RCVR 2 account No.) (Enter Tel. No.) Par. 4.5.3(10) Par. 4.5.3(11) IP RCVR 1 IP RCVR 2 000.000.000.000 (Enter IP address) 000.000.000.000 (Enter IP address) Par. 4.5.3(14) PSTN RPRT FORMAT SIA 4/2 1900/1400 4/2 1800/2300 Scancom SIA text contact ID Par. 4.5.3(18) Par. 4.5.3(15) 4/2 PULSE RATE 20 pps 33 pps 40 pps 10 pps Par. 4.5.3(19) GSM RPRT RETRY AUTO TEST TIME AUTO TEST CYCLE 2 attempts 4 attempts 8 attempts 12 attempts 16 attempts test time 12:00P (Enter time) test OFF test every 1 d test every 2 d test every 5d test every 7 d test every 14 d test every 30 d test every 5 h Par. 4.5.3(12) SMS RCVR 1 (Enter Tel. No.) Par. 4.5.3(16) PSTN RPRT RETRY 2 attempts 4 attempts 8 attempts 12 attempts 16 attempts Continues in next Figure 21 FIGURE 4.5 - DETAIL C continued REPORT EVENTS (see DETAIL C in previous drawing) Par. 4.5.3(20) Par. 4.5.3(21) LINE FAIL REPORT 4.5.3(20a) PSTN immediately 5 minutes 30 minutes 60 minutes 180 minutes donât report Par. 4.5.3(21c) Inst. downl code downl. code BBBB (Enter ) PSTN UP / DOWN Par. 4.5.3(20b) GSM/GPRS 2 minutes 5 minutes 15 minutes 30 minutes donât report Par. 4.5.3(21d) Upload option any time when system OFF 4.5.3(21a) Remote access rem. access ON rem. access OFF Par. 4.5.3(21b) Mast. downl code downl. code AAAA xxxx (Enter 4-digit code â0000â is not valid) Par. 4.5.3(21e) Up download tel# (Enter Tel. No.) Par. 4.5.3(22) GPRS UP/DOWN 4.5.3.(22a) My SIM TEL. # (Enter SIM card Tel. No.) Par. 4.5.3(24) RPRT CNFRM ALARM disable report enable + bypass enable report 4.5.3.(22b) 4.5.3.(22c) 1st Caller ID# 2nd Caller ID# (Enter 1st IP receiver Tel. No.) (Enter 2nd IP receiver Tel. No.) Par. 4.5.3(25) REPORT 24H ZONES both original audibl as panic silent as panic both as panic Par. 4.5.3(26) RECENT CLOSE recent cl. OFF recent cl. ON Par. 4.5.3(27) ZONE RESTORE report restore donât report Par. 4.5.3(28) SYS INACT REPORT disable rep. after 7d rep. after 14d rep. after 30d rep. after 90d 22 D-302017 FIGURE 4.5 - DETAIL D 4: PRIVATE REPORT Note The currently saved options are displayed with dark box at the right side of the display. To review the options, repeatedly click or until the desired option is displayed, then click OK (a dark box will be displayed at the right side). 4.5.4(1) REPORT TO PRVT Par. 4.5.4(2) VOICE REPORT Par. 4.5.4(3) SMS REPORT TEL# disable report alarms+alerts alarms alerts Par. 4.5.4(2a) 1st private tel# Tel. No. Par. 4.5.4(2d) 4th private tel# Tel. No. Par. 4.5.4(2b) 2nd private tel# Tel. No. Par. 4.5.4(2e) Redial attempts 1 attempt 2 attempts 3 attempts 4 attempts Par. 4.5.4(3a) 1st SMS tel# SMS Tel. No. Par. 4.5.4(3c) 3rd SMS tel# SMS Tel. No. Par. 4.5.4(2c) 3rd private tel# Tel. No. Par. 4.5.4(2g) Tel. acknowledge single ack all ack Par. 4.5.4(3b) 2nd SMS tel# SMS Tel. No. Par. 4.5.4(3d) 4th SMS tel# SMS Tel. No. 4.6 GSM Auto Detection The GSM/BBA modem auto detection feature enables automatic enrollment of the GSM modem into the PowerMaxExpress control panel memory. GSM modem auto detection is activated in one of two ways: after tamper restore and after reset (power-up or after exiting the installer menu). This causes the PowerMaxExpress to automatically scan GSM COM ports for the presence of the GSM modem. In the event that the GSM modem auto detection fails and the modem was previously enrolled in the PowerMaxExpress control panel, the message "Cel Rmvd Cnfrm" will be displayed. This message will disappear from the display only I OK . The modem is then considered after the user clicks as not enrolled and no GSM trouble message will be displayed. Note: A message is displayed only when the PowerMaxExpress alarm system is disarmed. 4.7 BBA Auto Detection The BBA modem auto detection feature enables automatic enrollment of the BBA modem into the PowerMaxExpress control panel memory. BBA modem auto detection is activated in one of two ways: after tamper restore and after reset (power-up or after exiting the installer menu). This causes the PowerMaxExpress to automatically scan BBA COM ports for the presence of the BBA modem. D-302017 In the event that the BBA modem auto detection fails and the modem was previously enrolled in the PowerMaxExpress control panel, the message "BBA Remvd Cnfrm" will be displayed. This message will I OK . disappear from the display only after the user clicks The modem is then considered as not enrolled and no BBA trouble message will be displayed. Note: A message is displayed only when the PowerMaxExpress alarm system is disarmed. 23 4.9 DEFINE CUSTOM This mode allows you to define up to 5 zones names (in addition to the zone names that can be defined in the DEFINE ZONES mode - see par. 4.3). (see figure 4.1a) 9. DEFINE CUSTOM I OK CUST. ZONES NAME TO EXIT I OK EDIT USER TERM 1 EDIT USER TERM 2 EDIT USER TERM 3 EDIT USER TERM 4 EDIT USER TERM 5 To edit User Terms, use the following buttons on the control panel keypad: press to scroll backward; press to scroll forward ; press to change from small caps to big caps ; press for space Figure 4.9 â Define Custom 4.10 DIAGNOSTIC TEST This mode allows you to test the function of all protected area wireless sensors / wireless sirens / wireless keypads and to receive / review information regarding the received signal strength. Three reception levels are sensed and reported: Received Signal Strength Indication: Reception Buzzer Response Strong Happy Tune twice ( - - - ââââ ) ( - - - ââââ) Good Happy Tune ( - - - ââââ ) Poor Sad tune ( ââââââââ ) The diagnostic test process is shown in figure 4.10. The following GSM/ GPRS messages are reported: Message Unit is OK GSM comm. loss Pin code fail GSM net. fail SIM card fail GSM not detected No GPRS service GPRS conn. fail Srvr unavailable IP not defined APN not defined SIM card locked Denied by server 24 When you are instructed to perform "walk test", walk throughout the site to check the detectors / sensors. When a detector/sensor is triggered into alarm, its name, number and the alarm reception level should be indicated (for example, "Bathroom", "Z19 strong") and the buzzer should sound according to the alarm reception level (1 of 3). IMPORTANT! Reliable reception must be assured. Therefore, a "poor" signal strength is not acceptable. If you get a "poor" signal from a certain detector, re-locate it and re-test until a "good" or "strong" signal strength is received. This principle should be followed during the initial testing and also throughout subsequent system maintenance. Description GSM / GPRS functioning properly. The GSM/GPRS module does not communicate with the Panel Missing or wrong PIN code. (Only if SIM card PIN code is enabled.) Unit failed with registration to local GSM network. SIM not installed or SIM card failure. GSM auto enroll failed to detect GSM/GPRS module. The SIM card does not have the GPRS service enabled. Local GPRS network is not available or, wrong setting to GPRS APN, user and/or password. VDNS Receiver cannot be reached â Check the Server IP Server IP #1 and #2 are not configured. APN is not configured. After entering a wrong PIN code 3 consecutive times the SIM is locked. To unlock it enter a PUK number. The PUK number cannot be entered by the PowerMax Pro. The VDNS denies the connection request. Check that the Panel is registered on the VDNS Receiver. D-302017 (see figure 4.1a) 10. DIAGNOSTICS NON-PARTITIONING ONLY WL SENSORS TEST WL SIRENS TEST DIAG. TESTING (Perform walk test) BATHROOM Z19 STRONG DIAG. TESTING S1 Example of test result display WL KEYPADS TEST CPU K1 WAIT S1 CPU=STRONG S2 CPU Example PLEASE WAIT... of test (alternating for 5 sec.) result S2 CPU=STRONG display Note Z1 POOR STRONG/GOOD/POOR/ Example âNOT OKâ (with siren No., LIVING ROOM of test S1 or S2 before) is (alternating for 5 sec.) displayed according to the result display wireless siren signal Z2 OK strength). S1=siren 1. S2 = siren 2. (Each time the OK button is pressed, CPU = Control Panel Unit the next test result is displayed) = 2 way comm. WAIT CPU=STRONG K1 K2 FRONT DOOR K2 CPU GPRS CONN. TEST (*) PLEASE WAIT... UNIT IS OK LAN CONNECT. TEST (*) PLEASE WAIT... UNIT IS OK CPU PLEASE WAIT... CPU=STRONG Note STRONG/GOOD/POOR/ âNOT OKâ (with keypad No., K1 or K2 before) is displayed according to the wireless siren signal strength). K1=keypad1 K2=keypad2 CPU = Control Panel Unit = 2 way comm. (*) When the OK button is pressed, the test result takes between 15 sec. to 4 mins. before it is displayed, depe nding on the severity of th e failur e. See par. 4.10 for a complete list of possible GSM/GPRS messages. Figure 4.10 - Diagnostic Test Flow Chart 4.11 USER FUNCTIONS This mode provides you with a gateway to the user functions through the regular user programming menu. You may: ⢠Program the 4 (private) telephone numbers ⢠Program user codes ⢠Enroll keyfobs ⢠Set the auto arm option ⢠Set arming time ⢠Set the squawk option ⢠Set the system time and time format ⢠Set the date and date format Refer to the User Guide for detailed procedures. Caution! If after having programmed the user codes the system does not recognize your installer code, this indicates you must have programmed a user code that is identical with your installer code. If so, access the user menu and change the code that is identical with your installer code. This will re-validate your installer code. 4.12 RETRIEVING FACTORY DEFAULTS If you want to reset the PowerMaxExpress parameters to the factory default parameters, you should enter the installer menu and perform the "FACTORY DEFLT" function, as described in the right side illustration. To get the relevant parameters defaults, contact the PowerMaxExpress dealer. Note: For PowerMaxExpress with 2 installer codes, INSTALLER code and MASTER INSTALLER code, only the master installer code enables to perform factory default function. Entering to/exit from the FACTORY DEFLT menu is shown in figure 4.1a 12. FACTORY DEFLT to restore ENTER CODE: This is a brief display after which all the factory defaults are retrieved. [installer code] PLEASE WAIT ... 4.13 SERIAL NUMBER The menu "13. SERIAL NUMBER" enables reading the system serial number and panel ID for support purposes only. Panel ID is a unique number of the control panel that is used for registering the PowerMaxExpress to VDNS when using GPRS. 4.14 CALLING UPLOAD/DOWNLOAD SERVER Note: This option is only used during the installation of panels monitored by compatible central stations. D-302017 This option allows the installer to initiate a call to the upload/download server. The server uploads the PowerMaxExpress configuration to its data base and can unload predefined parameters to the PowerMaxExpress . 25 Refer to Figure 4.1a to gain access to USER SETTINGS menu USER SETTINGS If UL/DL server tel. # is already defined (see par. 4.5.34) If UL/DL server tel. # was not defined before (see par. 4.5.34) COMMUNICATING TEL # NOT DEFINED INSTALLER MODE Displayed during dialing process ENTER CODE [installer code] 1. NEW INSTL CODE Displayed for half a minute approx. accompanied by sad (failure) melody 2. ENROLLING 3. DEFINE ZONES 4. DEFINE PANEL Displayed during download process 5. DEFINE COMM 9. DEFINE CUSTOM 10. DIAGNOSTICS 11. USER SETTINGS Displayed for half a minute approx. accompanied by happy (success) melody 12. FACTORY DEFLT 13. SERIAL NUMBER Dialing OK Dialing failed DOWNLOADING DIAL ATTEMPT FAIL Download OK Download failed DOWNLOAD OK Non-Partition mode READY 00:00 DOWNLOAD FAILED Displayed for half a minute approx. accompanied by sad (failure) melody Displayed for half a minute approx. accompanied by sad (failure) melody Partition mode P1 RDY 00:00 14. START UL/DL TO EXIT Figure 4.14 â Start UL/DL 4.15 ENABLING/DISABLING PARTITIONS This mode allows you to enable/disable the partitioning feature (optional). Partitioning allows you to divide the system into a maximum of four independently controllable areas. A different user code is assigned to each partition in order to limit or control access to each area. A partition can also be armed or disarmed regardless of the status of the other partitions within the system. When the partition feature is disabled, zones, user codes and features will operate the same as in a regular PowerMaxExpress unit. When partition is enabled, menu displays are changed to incorporate the partition feature. Refer to Figure 4.1a to gain access to USER SETTINGS menu USER SETTINGS INSTALLER MODE ENTER CODE [inst. code] 1. NEW INSTL CODE 15. PARTITIONING enable disable TO EXIT Note: Partitioning is an optional feature Figure 4.15 â Partitioning 4.16 WALK-TEST This mode (see Figure 4.1a) provides you with the means to conduct a periodic test, via the walk-test menu, at least once a week and after an alarm event. 26 D-302017 5. TESTING PROCEDURES 5.1 Preparations Make sure all windows and doors are closed. If all zones are secured (undisturbed), the display should read: HH:MM READY If the display is âNOT READYâ, query the control panel by pressing the I OK button repeatedly. The source(s) of the problem(s) will be displayed and read aloud. Take the necessary measures to eliminate the problem(s) before testing the system (see next paragraph). 5.2 Diagnostic Test To verify proper function of all detectors in the system, a comprehensive diagnostic test is required. To perform this test, refer to figure 4.10. 5.3 Keyfob Transmitter Test Initiate transmission from each transmitter enrolled as a keyfob unit (according to the list in Table A2, Appendix A). Use each transmitter to arm the control panel AWAY and immediately disarm it. Upon pressing the keyfob unitâs AWAY key, the ARM indicator should light. The display should respond as follows: ARMING AWAY PLEASE EXIT information noted in Table A.2, Appendix A. Verify that the AUX button performs its duty as programmed. If the AUX (@) button is defined as âINSTANTâ, press the AWAY button and then the AUX button. The response should be: ARMING (alternating) PLEASE The exit delay beeps will begin. Press the keyfob unitâs DISARM ( ) key. The ARM indicator should extinguish, the announcement âDisarm, ready to arm" should be heard and the display should revert to: READY EXIT NOW and the exit delay beeps will start. Press the DISARM ( ) key immediately to disarm. If the AUX (*) button is defined as "skip exit delay", press the AWAY button and while you hear the exit beeps press the AUX button â the exit beeps will be stopped immediately and the system will be armed AWAY. Press the DISARM key ( ) immediately to disarm the system. 5.4 Emergency Transmitter Test Initiate transmission from each transmitter enrolled to an emergency zone (according to the list in Table A3, Appendix A). For example, upon pressing the transmit button of an emergency transmitter enrolled to zone 22, the display should read: Z22 NOW INSTANT EMERGENCY (alternating) VIOLATED It is advisable to let the central station know that you are conducting this test, or just disconnect the telephone line from the PowerMaxExpress during the test, to prevent false alarms. HH:MM Test the AUX button in each keyfob in accordance with the 6. MAINTENANCE 6.1 Dismounting the Control Panel A. Remove the screw that fastens the front unit to the back unit (see figure 3.1H). B. Remove the 3 screws that fasten the back unit to the mounting surface (see figure 3.1A) and remove the control panel. 6.2 Replacing the Backup Battery Replacement and first-time insertion of battery pack is similar (see figure 3.1C). With fresh battery pack, correct insertion and tightened battery compartment lid, the TROUBLE indicator should extinguish. However, the âMEMORYâ message will now blink in the display (caused by the âtamperâ alarm you triggered when opening the battery compartment lid). Clear it by arming the system and immediately disarming. 6.3 Fuse Replacement The PowerMaxExpress has an internal fuse that has automatic reset. Therefore, there is no need to replace fuse. When over current condition occurs, the fuse cuts off the circuit current. Upon fault current being removed for several seconds, the fuse is automatically reset and allows current flow through the circuit again. 6.4 Replacing/Relocating Detectors Whenever maintenance work involves replacement or relocation of detectors, always perform a full diagnostic test according to par. 4.10. Remember! A "poor" signal is not acceptable, as stated at the end of the test procedure. 7. READING THE EVENT LOG Events are stored in the event log. You can access this log and review the events, one by one. If the event log fills up completely, the oldest event is deleted upon registration of each new event. The date and time of occurrence are memorized for each event. D-302017 When reading the event log, events are shown in chronological order - from the newest to the oldest. Access key and to the event log is provided by clicking the not through the installerâs menu. Reading and erasing process of the event log is shown in the next drawing. 27 CODE _ _ _ _ (Enter 4-digit installer code) (**) CLEAR EVENT LOG LIST OF EVENTS I OK I OK I OK TO DELETE Latest Event I OK
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Creator : jacob_s Title : Microsoft Word - D-302017 Rev 0 PowerMaxExpress installer guide.doc Create Date : 2009:02:19 10:58:29+02:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2009:02:19 10:59:46+02:00 Metadata Date : 2009:02:19 10:59:46+02:00 Producer : Acrobat Distiller 8.0.0 (Windows) Document ID : uuid:dc0ba3f7-7e7d-414b-89a1-7b94d75c7cd7 Instance ID : uuid:7a9de2f5-a04d-4a0f-9991-b0fb2292c1c5 Page Count : 36 Author : jacob_sEXIF Metadata provided by EXIF.tools