Visonic VXS5 Proximity Access Control Unit User Manual 5 pages

Visonic Inc. Proximity Access Control Unit 5 pages

5 pages

DE6290 1VXS-5Single-Door Stand Alone ProximityAccess Control System Installation Instructions1. INTRODUCTIONThank you for selecting the VXS-5, the most economical,proximity access control system on the market designed for smallinstallations. It is a stand alone, self contained access controlsystem built into a proximity reader housing. The VXS-5 meetsthe need of many users for an electronic door strike controlsystem with a memory capacity of 10 keys or less. A small office,private home or apartment would be the ideal application for theVXS-5.The VXS-5 memorizes a master key plus 10 keys and comeswith five free proximity tags.The system is powered from a 12 VDC external power supply.The EMS (Electromagnetic Door Strike) is energized with 12 VDCwhen a valid key is presented. System wiring requires 4 leadsonly - 2 for power and 2 for the EMS. VXS-5 Reader and Controller Proximity Key Tag2. SPECIFICATIONSVXS-5 CONTROLLERFrequency: 125 kHzPower Input: 12 - 14 VDCPower Output to EMS: 12 VDCMaximum Current: 150 mA (Idle), 650 mA (EMS open)Indicators: Tricolor LED - Green, Red, AmberTag Reading Range: 50 - 100 mm (2-4 in.)Tag Codes Possibilities: 1012 possible combinationsKey Memory: 10 keysSize (H x W x D): 116 x 70 x 16.8 mm (4-1/2 x 2-3/4 x 5/8 in.)Weight: 121.5 g (4.3 oz)Operating Temperature: -20°C to 50°C (-4° to 122°F)Color: Dark grayTAG-1 PROXIMITY TAGSize: (H x W x D): 53 x 35  x 7 mm (2-1/8 x 1-3/8 x 9/32 in.)Weight: 5.5 g (0.2 oz)Color: Dark gray3. INSTALLATION• Insert a screwdriver into the recess at the bottom or top of thecase, and separate the cover from the reader.• Drill a hole in the wall for the cable.• Place the base on the installation surface while passing thecable through the hole, mark two points for drilling, drill theholes, and insert the enclosed plastic anchors, if necessary.• Fasten the base to the mounting surface, using the enclosedscrews.• Connect each wire to the corresponding terminal according tothe following list: Wire color  Function Black  12V Power [+] Black/White  12V Power [-] White  EMS [+] White/Orange  EMS [-]• Replace the reader’s cover, ensuring that the cover is alignedcorrectly. This will make the LED visible.   4. PROGRAMMING Note: The VXS-5 exits programming automatically and reverts tonormal operation if no activity is detected for 10 seconds. 4.1. Initial Non-programmed State When first connected to power, the LED blinks amber and redalternately to indicate that there is no master key.• Present one of the keys supplied with the unit. This key willbecome the master key.• The VXS-5 accepts the master key and the LED turns amberto indicate the idle state. Note: It is recommended to keep the master key in a safeplace. The master key is used for programming only and cannotbe used for access control. 4.2. Add Keys Hold the master key next to the unit for 10 seconds. The LED willstart blinking green at the rate of 2 Hz (twice a second) toindicate the ADD mode. While in ADD mode:• Present a key to be added.• The green LED lights up steadily for 2 seconds to indicateacceptance of the new key.• To add more keys, wait until the unit resumes blinking greenand present a new key.
2DE6290• When the memory is full with 10 user keys, the VXS-5 will notaccept any more keys and continue blinking green at 2 Hzeven when a new key is presented.• To exit the ADD mode wait 10 seconds with no activity. 4.3. Delete Keys While in the ADD mode, hold the master key near the unit for 10seconds.•  The LED starts blinking red, thus indicating the DELETEmode.•  If the key to be deleted is available, simply present it to theunit for deletion. The red LED lights up steadily for 2 secondsto indicate that the key has been deleted. If the key is lost or stolen, all keys must be deleted and theavailable keys have to be added back in.• While in the DELETE mode, present the master key to theVXS-5 for about 10 seconds.• The red LED will light up steadily for 2 seconds to indicate thatall keys have been deleted.• Exit DELETE mode by waiting 10 seconds with no activity.• Enter the ADD mode (see 4.2) and add all available keys. 4.4. Set Unlock Time The default unlock duration is 5 seconds. To change it, you needto be in the DELETE mode (see 4.3).• While in the DELETE mode present the master tag for aboutone second.• The LED blinks amber at 2 Hz rate.• Present a valid (non-master) key for the required unlockduration and remove it promptly.• The VXS-5 will define the new unlock duration as the length oftime the key was presented. 4.5. Reset Master Tag Resetting the master is performed by connecting the EMS- to thePower- in the following order:•  While the unit is connected to power, touch the EMS- wire tothe -12V Power for about 1/2 second•  Wait about 2 seconds (count 1.. 2.. 3..)•  Touch the EMS- wire to the -12V Power again, for 1 secondIt may take some practice to get it right.  Eventually the master iserased, and the LED blinks red / amber alternately indicating thata new master is needed (see 4.1).Note: When deleting the master tag, all other keys are notaffected.5. OPERATIONDuring normal operation, the LED lights amber to indicate the idlestate. When presenting a valid key, the LED lights green andopens the lock for 5 seconds (default unlock duration).If a key is invalid, the LED lights red for 2 seconds.If more than 5 consecutive invalid keys are presented with lessthan 5 seconds between every two keys, the VXS-5 increases thetime of the red LED to 5 seconds and reverts to 2 seconds whena valid key is presented or if more than 60 seconds have passedwith no activity.This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:(1)  This device may not cause harmful interference, and(2)  this device must accept any interference received, including interference that may cause undesired operation.This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limitsare designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses and canradiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio andtelevision reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause suchinterference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of thefollowing measures:– Re-orient or re-locate the receiving antenna.– Increase the distance between the device and the receiver.– Connect the device to an outlet on a circuit different from the one which supplies power to the receiver.– Consult the dealer or an experienced radio/TV technician.WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user'sauthority to operate the equipmentWARRANTYVisAccess Ltd. and/or its subsidiaries and its affiliates ("the Manufacturer") warrants itsproducts hereinafter referred to as "the Product" or "Products" to be in conformance withits own plans and specifications and to be free of defects in materials and workmanshipunder normal use and service for a period of twelve months from the date of shipment bythe Manufacturer.  The Manufacturer's obligations shall be limited within the warrantyperiod, at its option, to repair or replace the product or any part thereof. The Manufacturershall not be responsible for dismantling and/or reinstallation charges. To exercise thewarranty the product must be returned to the Manufacturer freight prepaid and insured.This warranty does not apply in the following cases: improper installation, misuse,failure to follow installation and operating instructions, alteration, abuse, accident ortampering, and repair by anyone other than the Manufacturer.This warranty is exclusive and expressly in lieu of all other warranties, obligations orliabilities, whether written, oral, express or implied, including any warranty ofmerchantability or fitness for a particular purpose, or otherwise.  In no case shall theManufacturer be liable to anyone for any consequential or incidental damages for breachof this warranty or any other warranties whatsoever, as aforesaid.This warranty shall not be modified, varied or extended, and the Manufacturer does notauthorize any person to act on its behalf in the modification, variation or extension of thiswarranty. This warranty shall apply to the Product only.  All products, accessories orattachments of others used in conjunction with the Product, including  batteries, shall becovered solely by their own warranty, if any.  The Manufacturer shall not be liable for anydamage or loss whatsoever, whether directly, indirectly, incidentally, consequentially orotherwise, caused by the malfunction of the Product due to products, accessories, orattachments of others, including batteries, used in conjunction with the Products.The Manufacturer does not represent that its Product may not be compromised and/orcircumvented, or that the Product will prevent any death, personal and/or bodily injuryand/or damage to property resulting from burglary, robbery, fire or otherwise, or that theProduct will in all cases provide adequate warning or protection. User understands that aproperly installed and maintained alarm may only reduce the risk of events such asburglary, robbery, and fire without warning, but it is not insurance or a guarantee that suchwill not occur or that there will be no death, personal damage and/or damage to propertyas a result.The Manufacturer shall have no liability for any death, personal and/or bodily injuryand/or damage to property or other loss whether direct, indirect, incidental,consequential or otherwise, based on a claim that the Product failed to function.However, if the Manufacturer is held liable, whether directly or indirectly, for any loss ordamage arising under this limited warranty or otherwise, regardless of cause or origin, theManufacturer's maximum liability shall not in any case exceed the purchase price of theProduct, which shall be fixed as liquidated damages and not as a penalty, and shall be thecomplete and exclusive remedy against the Manufacturer.Warning: The user should follow the installation and operation instructions and amongother things test the Product and the whole system at least once a week.  For variousreasons, including, but not limited to, changes in environmental conditions, electric orelectronic disruptions and tampering, the Product may not perform as expected.  The useris advised to take all necessary precautions for his/her safety and the protection of his/herproperty.6/91
DXXXX 3Technical Dept.:  35 Hamelacha St. Carmiel 20100 ISRAEL Tel: 972 4 9081115 Fax: 972 4 9081116Sales Dept.:  30 Habarzel St. Tel Aviv 69710 ISRAEL Tel: 972 3 645 6789 Fax: 972 3 645 6891Internet:  www.visaccess.comVisAccess Ltd. 1999     VXS-5    DE6290-  (REV. 0, 9/99)

Navigation menu