Vita Course Technologies DISCOVERY Non-invasive Hemodynamic Blood Pressure Monitor User Manual

Vita-Course Technologies Co., Ltd. Non-invasive Hemodynamic Blood Pressure Monitor

User Manual

Download: Vita Course Technologies DISCOVERY Non-invasive Hemodynamic Blood Pressure Monitor User Manual
Mirror Download [FCC.gov]Vita Course Technologies DISCOVERY Non-invasive Hemodynamic Blood Pressure Monitor User Manual
Document ID3826947
Application IDOTpeOEouLV2AOUlQ4ZpLRA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize76.8kB (959972 bits)
Date Submitted2018-04-23 00:00:00
Date Available2018-04-24 00:00:00
Creation Date2018-04-09 16:45:40
Producing SoftwareMicrosoft? Office Word 2007
Document Lastmod2018-04-09 16:45:40
Document TitleUser Manual
Document CreatorMicrosoft? Office Word 2007
Document Author: liwei wang

Non-invasive Hemodynamic Blood
Pressure Monitor
Discovery 1
User Manual
Vita-Course Technologies Co., Ltd.
User Notes:
Thank you for using the Non-invasive Hemodynamic Blood Pressure Monitor.
Please read the instruction manual carefully before using the product.
Vita-Course shall not take corresponding responsibility for any abnormality or any personal or
machine damage caused by the irregular use, maintenance and reposition without the
guidance of the instruction, and shall not provide free maintenance for such failures.
This manual is only applicable to Discovery 1 type Non-invasive Hemodynamic Blood Pressure
Monitor (hereinafter referred to as "equipment")
Contraindications: unclear
Copyright and Disclaimer
The copyright of the instruction belongs to Vita-Course Technologies Co., Ltd. (hereafter
referred to as “Vita-Course Technologies”). All rights reserved. No unit or individual could
copy or disseminate any part or all of the instruction without prior written permission in any
form or by any means. Otherwise, the legal liability will be held accountable.
Vita-Course Technologies has the final interpretation of the instruction and reserves the right
to upgrade and alter specifications as well as contents of the products. If there are upgrade and
change, we won’t track users’ upgrade.
Vita-Course Technologies tries its best to make contents of the instruction be complete and
accurate, but cannot guarantee that the instruction is free from any errors or omissions.
Vita-Course Technologies shall not bear any responsibility for any consequences arising from
the irregular execution of the contents of this instruction.
All the copyrights, trademarks, patent applications and patent rights that may arise from the
instruction or relate to the products of Vita-Course Technologies are owned by Vita-Course
Technologies. Without the written permission agreement, this instruction does not grant any
license of any of the above rights and the instruction itself cannot be used as a license
agreement to authorize any of the above rights.
If other units or individuals, without the written permission, use or disseminate the contents of
the instruction without authorization, which accordingly affects the interests of themselves or
the third parties, Vita-Course Technologies shall not shoulder any responsibility
File Updating
This instruction was finally revised by Vita-Course Technologies on February 22, 2017.
Safety Announcements:

Warning:
The patient or the operator may die or be seriously injured when the equipment
is operated mistakenly.

Caution : The damage may happen to people or equipment when the equipment is
employed incorrectly.
Note:Important tips on operation and use
 Warning
1. Before the use of the equipment, users need to check the equipment so as to ensure its safe use
and normal work.
2. Do not use the equipment in these places full of the flammable gas and explosion.
3. Allergic reactions may occur in very few other users. If it happens, please stop using the
equipment immediately.
4. When users connect other equipment to their bodies, please be cautious:
the total leakage
current may exceed the permissible limitation, causing potential damage to the user.
5. Equipment accessories, such as pulse wave probes and cables whose materials have been tested
for biocompatibility, cannot be replaced at will. Please use the accessories provided by our
company in case it may lead to some adverse consequences related to safety and biocompatibility
etc.
6. All the connections of applications should be away from the user's neck so as not to choke the
user's neck.
7. Before carrying out maintenance, please turn off the equipment.
8. The scrap of this equipment and parts shall comply with local laws and regulations.
9. This equipment belongs to professional medical equipment, and only the professionals
appointed by the factory are responsible for the maintenance.
10. Apply to those who are 16~70 years old.
11. Please close the equipment and evacuate the sensor during magnetic resonance imaging MRI
scanning; if not, it may cause burns or affect the accuracy of MRI images as well as equipment.
12. Please make sure children can't touch it when you keep it.
13. Please do not use the high frequency operation equipment at the same time so as not to affect
the measurement accuracy of the equipment.
Caution
注意
1. Please keep and use the equipment within the regular range of temperature, humidity and
atmospheric pressure; if not, it would lead to damage of the equipment and inaccurate measurement
results.
2. Please do not directly open the equipment after it is affected with damp to avoid damaging the
equipment, and use it after it is dried.
3. The equipment is limited to one user at the same time.
4. Please be away from equipment with strong electromagnetic interference, such as microwave
ovens, large printers, induction cooker, etc. when using it.
5. When using high frequency surgical equipment, close the equipment and evacuate the sensor.
Note
1. When common arrhythmias, such as atrial fibrillation, premature ventricular fibrillation, and
atrial fibrillation, occur, they may affect the accuracy of output results.
2. Professionals shall interpret the measuring results of the equipment.
3. The value of blood pressure measured by this equipment is equivalent to that measured by
auscultation, and the error is in line with the requirements specified in YY 0667-2008.
4. If those who are equipped with heart pacemaker, a stent and beyond the measurement range
use the equipment, the accuracy of the output results will be affected.
5. Please remove your callus of your hands and nail polish before using the equipment.
6. Check the battery power after each use. When the battery is less than 1 cell, you must charge the
battery, and ensure sufficient storage of electricity.
7. Please stop using the equipment if there is any indication of malfunction.
8. Signal input and output interfaces can only be connected to the required devices.
Table of Content
Chapter 1
Summary ......................................................................................................................................... 1
1.1 Characteristics of products .................................................................................................................................................... 1
1.2 Intended Use/Instruction for use .......................................................................................................................................... 1
1.3 The scope of products ........................................................................................................................................................... 1
1.4 Structure ............................................................................................................................................................................... 1
1.5 Product classification ............................................................................................................................................................ 1
1.6 Operating environment ......................................................................................................................................................... 2
1.7 Safety .................................................................................................................................................................................... 2
Chapter 2 Wearing and Connecting ...................................................................................................................... 3
2.1 Out of box audit .................................................................................................................................................................... 3
2.2 Appearance presentation ...................................................................................................................................................... 3
2.3 Marks .................................................................................................................................................................................... 4
2.4 Wearing ................................................................................................................................................................................. 4
Chapter 3 Interface Introduction and Operation .................................................................................................. 7
3.1 Boot ....................................................................................................................................................................................... 7
3.2 Connecting APP ..................................................................................................................................................................... 7
3.3 Calibration ............................................................................................................................................................................. 8
3.4 Measurement ........................................................................................................................................................................ 9
3.5 Measuring result ................................................................................................................................................................... 9
3.6 Prompt in measurement ..................................................................................................................................................... 10
3.7 Battery level ........................................................................................................................................................................ 11
Chapter 4 Structural Features and Working Principle ..........................................................................................13
4.1. Overall structure framework chart ..................................................................................................................................... 13
4.2 Principle of blood pressure measurement .......................................................................................................................... 13
Chapter 5 Technical Characteristics .....................................................................................................................14
5.1 Blood pressure .................................................................................................................................................................... 14
5.2 Pulse wave........................................................................................................................................................................... 14
5.3 Size and weight ................................................................................................................................................................... 14
Chapter 6 Maintenance, Preservation, Storage and Transportation ....................................................................15
6.1. Cleaning of equipment ....................................................................................................................................................... 15
6.2 Cleaning of accessories ....................................................................................................................................................... 15
6.3. Maintenance test ............................................................................................................................................................... 16
Chapter 7 Storage and Transportation of Equipment ..........................................................................................17
7.1 Storage ................................................................................................................................................................................ 17
7.2 Transportation..................................................................................................................................................................... 17
Chapter 8 Troubleshooting ..................................................................................................................................18
8.1 Check the equipment and accessories ................................................................................................................................ 18
8.2 Check cable and charging line ............................................................................................................................................. 18
8.3 Troubleshooting .................................................................................................................................................................. 18
8.4 Disposal of equipment ........................................................................................................................................................ 19
Chapter 9 Appendix .............................................................................................................................................20
The warranty ordinance of the product ...............................................................................................................25
Chapter 1
Summary
1.1 Characteristics of products

Noninvasive and cuff-less equipment

The self-contained screen to monitor blood pressure measurement data; real-time clock to
display the time.

Rapid measurement of blood pressure and pulse rate.

Automatic measurement.

Dynamic continuous measurement can keep 24 hours.

Real-time power display, low battery alert and auto sleep for power save.

Wireless connection via display terminal, such as Bluetooth and intelligent mobile phone, etc.
1.2 Intended Use/Instruction for use
The Discovery 1 - Non-invasive blood pressure trending device is a small, lightweight, handheld,
device intended for measuring and display of Blood Pressure trending (systolic and diastolic) and
spot-check of Peripheral pulse rate (PPR) and Peripheral pulse wave (PPW). Measurement is
performing on capillary fingertip tissue (other than the thumb). The ring finger is the recommended
site. The results of each measurement are stored in the system memory.
It is intended to be used by any person aged above 18 years old.
1.3 The scope of products
Apply to medical institutions or families to monitor the blood pressure and pulse rate of the human
body.
1.4 Structure
The cuff-less equipment consists of a host, mobile APP software and accessories.
Accessories include : Pulse wave probe and cable, arm band (optional), power adapter, data
transmission line / charging line.
1.5 Product classification
According to the classification of medical device management categories: Class II
According to the type of protection against electric shock: class II internal power supply equipment
According to the degree of protection against electric shock: BF-type equipment
According to the degree of protection against harmful liquid into: ordinary equipment (the closed
equipment that cannot stop the liquid into)
According to the safety degree related to a mixture of flammable anesthetizing gas and air or
oxygen or Nitrous Oxide: not applicable in the place existing flammable anesthetizing gas.
According to the work system: continuous operation of equipment
1.6 Operating environment
1.Operating temperature:5 ℃~45 ℃;
Relative humidity:10%~95%( non-condensing);
Atmospheric pressure:70.0 kPa~106.0 kPa;
2.Working mode: internal power supply: DC 3.7, V/2200, mAh;
Charging mode: power adapter input voltage: 220 V, 50Hz.
1.7 Safety
1. Comply with IEC 60601-1:2012 “Medical electrical equipment; Part 1: General requirements for
safety”
2. Comply with IEC 60601-1-2:2014 “Medical electrical equipment – Part 1-2: General requirements
for basic safety and essential performance – Collateral Standard: Electromagnetic disturbances –
Requirements and tests”
3. Comply with ISO 80601-2-61 “Particular requirements for basic safety and essential
performance of pulse oximeter equipment”
Chapter 2 Wearing and Connecting
2.1 Out of box audit
1、Open the packing box and take out the equipment and accessories.
2、Open the random file and check accessories according to the packing list:
1) Check whether the equipment has any mechanical damage.
2) Check whether all accessories including plug, wires and sensor have scoring or shortness.
3) Before using the equipment, check whether the equipment and accessories are in danger or have
abnormality; if it has abnormality (such as patients’ cable rupture, shell cracking, etc.), do not carry
out measurement.)
If you have any questions, please contact the seller or contact us. We will provide you with
satisfactory service in time.
2.2 Appearance presentation
Non-invasive Hemodynamic Blood
Pressure Monitor
Pulse wave probe interface
Charging interface
USB connection port
Screen
Pulse wave probe
On/off key
Non-invasive Hemodynamic Blood
Pressure Monitor
Figure 2.1 product drawing
Content
Description
Press the power on / off button for 1 second to turn on the equipment
On/off key
Press the power on / off button for 4 seconds to turn off the battery
Screen
Display interface content
USB connection port
Connect
line USB to charge
upgrade the program and export
data
Pulse
wave
probe
Connect pulse wave probe
interface
2.3 Marks
Content
Description
Be careful!Consult the random file
USB connection port
PPG
Pulse wave probe
BF applied part
On /off button
Non-Ionizing Radiation
2.4 Wearing
Please wear arm belt as shown in Figure 2.2
Figure 2.2 wearing arm belt
2.4.1 The connection of pulse wave probe
Connect the plug of the pulse wave probe to the interface corresponding to the equipment.
When you connect them, you could hear "Kaka".
As shown in Figure 2.3, the finger of the person to be measured (using the index finger of the left
hand) is extended into the probe.
Figure 2.3 the finger position of wearing the clip pulse wave probe
Safety attentions for pulse wave measurement
Before the use, please check the pulse wave probe and if there is worn cable or abnormality, please
immediately stop using the equipment.
Do not place the pulse wave probe on the limb with an artery or venous infusion tube because
such circumstance will affect the accuracy of measuring results.
Do not look directly at the pulse wave probe when using it in order to avoid the damage to eyes.
Please stop using the probe if you find out its temperature is obviously increasing.
Please do not use the pulse wave probe for a long time when the ambient temperature is above 40
degrees in order to avoid burns.
 Normally, at least once every 3 hours, change the wearing position. Inspect the worn area every 1
to 2 hours to ensure good skin condition is aligned with the correct light. If local skin condition
changes, please change the position of the pulse wave probe in time.
 Constant use of the pulse wave probe can cause discomfort or tenderness, especially in patients
with microcirculatory disturbances, so preferably change the wearing position once every 2 hours.
 As for some special patients, the measuring part of the pulse wave probe should be checked
carefully and do not place the sensor in a edematous or fragile tissue!
Those who are measured should not have long fingernails and apply nail polish, etc.
If those who are measured have thick callus of fingers, the finger with less callus is preferred.
 Do not bend, twist cable.
 The blood pressure cuff and pulse wave sensor that need to be pressurized cannot be used on the
same limb because measuring the blood pressure on the same limb will affect the monitor of pulse
wav.
Do not use the broken pulse wave probe.
Do not completely put the probe into the water, solution or cleaning agent because the probe is
lack of waterproof function.
Please hold the forepart of the plug to pull the plug.
The pulse wave probe can be used repeatedly. Before that, the probe needs cleaning. The specific
methods are described in a chapter related to maintenance.
In order to ensure the safety and effectiveness, it’s necessary to use the pulse wave
probe provided by our company and stop the interface of the pulse wave probe from
being connected to other things.
Chapter 3 Interface Introduction and Operation
3.1 Boot
Press the button of switch machine for 1 second. The system enters the boot interface successfully,
as shown in figure 3.1.
Welcome to use
Figure 3.1 boot interface
Check the battery power after each use. When the battery is less than 1 cell, you must charge the
battery, and ensure sufficient storage of electricity.
If there are indications or signs of broken function, please stop using the equipment
immediately and directly contact with seller or our company.
3.2 Connecting APP
Before the measurement, the equipment needs to connect to terminal equipment via Bluetooth and
intelligent mobile phone as shown in figures 3.2 and 3.3. Users need to download APP “Discovery
1”, which is related to terminal devices. And mobile APP software can be downloaded from the
company's official website.
Running environment of software:
Software running environment:
IOS8.0 and above software version, support iPhone 5, iPhone 5S and above hardware
Android 4.3 and above software version
Bluetooth supports 4.0BLE protocol
Displaying pictures and introduction of measurement results of physiological data could be
seen from the APP operation assistant!
Figure 3.2 the equipment is not connected.
Content
Name
Meaning
Bluetooth signal icon
Indicating that Bluetooth is on
Power icon
Displaying the situation of the use of
battery
12345678
sequence code
The sequence code consists of 8 digits
and letters.
Figure 3.3 the equipment is connected
Content
14:37
Name
Meaning
Bluetooth signal icon
Indicating that Bluetooth connects with APP
Time
Displaying the current synchronization time
3.3 Calibration
The equipment must be calibrated before being measured for the first time and specific procedure
should be:
1. Wearing the equipment that needs to be connected to APP
2. Select the calibration function of the mobile App and start calibration measurement. In this
process, the interface of the equipment is shown in figure 3.4:
Zhang Aihua
Calibration is in
progress, please wait a
moment.
Figure
3.4 calibration measurement
3. After the finish of calibration measurement, it is necessary to use mercury equipment or other
equipment to measure the user blood pressure value, and input the measurement result into the
corresponding window of APP.
Attention :
1. For the sake of pursuing more accurate measuring results of blood pressure.
2. Desktop equipment and other equipment that used for calibration must be qualified products,
which are approved by the National Metrology Department and periodically calibrated. Methods of
blood pressure measurement refer to Guidelines for Chinese blood pressure measurements.
Input methods refer to App operation guide.
3.4 Measurement
1. Set up the measurement mode and then carry out measurement as shown in figure 3.5;
 If you want the equipment to enter automatic measurement and dynamic continuous
measurement mode, please ensure that the battery power is more than 3 squares
2. After the equipment enters dynamic continuous measurement mode, you could look at the
present situation of measurement by connecting mobile phone APP to the equipment and after the
mobile phone APP is disconnected, the dynamic continuous measurement of the equipment is not
affected.
Zhang Aihua
Zhang Aihua
Figure 3.5 measurement interface
Content
Name
Dynamic continuous
Indicating that the equipment is in dynamic
measurement mode
continuous measurement mode
Mark of dynamic
Indicating that the equipment is in dynamic
measurement mode
Zhang Aihua
120/80 mmHg
Meaning
measurement mod
Power Icon
Displaying the condition of using the battery
Name
Representing patients’ name
Blood pressure value
Representing a systolic / diastolic pressure
value
70 bpm
Pulse rate value
Representing pulse rate value
3.5 Measuring result
After the finish of measurement, the value of measuring results will be displayed. If the result is
normal, it would be like the figure; the blood pressure analysis report can be printed through mobile
phone APP and the specific operating procedure can be seen in guidance of APP operation;
Zhang Aihua
Figure 3.6 the interface of measuring result
3.6 Prompt in measurement
3.6.1 Prompt of starting the measurement
1. In the dynamic continuous mode, if the interval of day ≥ 30minutes, within five minutes before the
measurement, prompt will start in the form of vibration; in addition to that, it will display such
indication “Going to start the measurement”.
It is like the figure 3.7.
Zhang Aihua
Going to start the
measurement
Figure 3.7 start the prompt during the day
2. If the interval of day < 30 minutes, there is no prompt.
3. Within five minutes before the start of the measurement, prompt will start in the form of vibration;
in addition, it will display “Start the measurement during the night” .
It is like the figure 3.8.
Zhang Aihua
Start the
measurement
during the night
Figure 3.8 start the prompt during the night
3.6.2 Abnormal prompt of the connection of the pulse wave probe
In calibration mode, single mode, automatic mode, dynamic mode, the pulse wave probe falls off or
connects abnormally, and the screen shows "abnormal connection ". The equipment will generate a
vibration reminder. As shown in figure 3.9:
Zhang Aihua
Abnormal
connection
Figure 3.9 Abnormal connection
If you want to withdraw from the automatic mode and dynamic mode, you need to connect your
mobile phone to the product and then make APP enter the corresponding mode, and eventually
click Cancel Measurement to achieve the final withdrawal.
If it is being measured, you need to wait
until the measurement is over before you can exit the measurement mode.
3.6.3 Measuring influencing factors
During measurement, the following factors may affect the accuracy of measurement:
1. The ambient light is too strong or there is a strobe light or a flash light (such as a fire light). (Hint:
cover the area of the blood oxygen probe with opaque material.)
2. Excessive movement of users, excessive vibration.
3. Severe cough, laughter, anger and other emotional fluctuations occurred during the
measurement.
4. Effect of electromagnetic field, such as nuclear magnetic resonance equipment--microwave ovens,
large printers, induction cooker and so on.
5. The impact of high frequency surgical equipment and electrosurgical devices
6. Wrong position of placing the pulse wave probe or the incorrect use of accessories.
7. Hypovolemic shock due to blood loss, burns, trauma, etc., shock caused by infection, allergies,
nerves, cardiogenic diseases and ischemia and hypoxia in surrounding tissues caused by various
causes.
8. The existence of certain cosmetics, such as nail polish, cosmetics and so on.
3.7 Battery level
1. The information of battery status is shown on all screens fixedly. These battery icons tell you the
current battery status (see the following table)
Icon
Description
The electricity=100%
The electricity≤75%
The electricity≤50%
The electricity≤25%
The electricity≤10%
When the power is switched on, the power icon is always blinking.
2. Prompt of low battery: when the electricity is less than 25%, there will be a hint of low battery as
shown in Figure 3.10. It will return to the original interface after 10 seconds. When the electricity is
less than 5%, it will show a low battery. As shown in Figure 3.11, the device will automatically turn off
after 10 seconds.
Low power, please
charge
Figure 3.10 prompt of low power 25%
Low power,
automatic shutdown
Figure 3.11 prompt of low power 5%
3. When the battery is off and charged, the battery icon on the screen flashes in turn, showing the
percentage of the electricity, as shown in figure 3.12;
Charging
Figure 3.12 the interface of the battery being off and charged
 The time of charge once: 4~6 hours
 During the charge, please pull the pulse wave probe.
Given a built-in battery in the equipment, regardless of whether the use or the boot, the built-in
battery will be charged when the equipment is connected with alternating current. If the battery is
full, please disconnect the AC immediately because charging time should not exceed 12 hours.
 Please use the power adapter configuration provided by our company; stop any other objects
from being into the charging interface.
Chapter 4 Structural Features and Working Principle
4.1. Overall structure framework chart
Button operation
OLED display
Network communication
Central processing unit (CPU)
Blood pressure circuit template
Functional
accessories
Pulse wave
probe
Storage
Battery
Charger
Figure 4.1 Overall structure framework chart
4.2 Principle of blood pressure measurement
The product is designed to calculate the blood pressure I terms of conduction time of pulse and
wave parameters of pulse. This method is proposed based on interdependent characteristics
between conduction time of the pulse wave along the arterial as well as characteristic
parameters of the pulse wave and arterial pressure. Through the determination of the PPG
signal, conduction time of the pulse wave along thee arterial and other correlation variables
would be obtained and accordingly the systolic and diastolic pressures of the body are gotten
by fitting operation. The pulse rate can be obtained by calculating the pulse wave signal.
Chapter 5 Technical Characteristics
5.1 Blood pressure
1. Measuring range of blood pressure
Systolic pressure 50 mmHg ~200 mmHg
Arterial pressure 40 mmHg ~160 mmHg
2. Stability of measurement results
Average deviation≤3 mmHg。
3. Accuracy of measurement
Within the range of systolic pressure 70 mmHg~180 mmHg、Arterial pressure 40 mmHg~130
mmHg:Mean difference≤±0.67 kPa(±5 mmHg),standard deviation≤1.067 kPa(8 mmHg)
4. Display resolution of blood pressure:1 mmHg
5.2 Pulse wave
5.2.1 Sensor
1. Type:Photodiode;
2. Wavelength:infrared:905 nm,red light:660 nm;
3. Maximum average optical output power:≤2 mW;
4. Update cycle of data:1 s。
5.2.2 Range and accuracy
1. Pulse range:40 bpm~240 bpm;
2. Accuracy:±2% or ±2 bpm,choose the big value;
3. Resolution :1 bpm。
5.3 Size and weight
Host size: 90 mm x 64 mm x 17 mm
Host net weight:about 150 g
Chapter 6 Maintenance, Preservation, Storage and
Transportation
In order to ensure the equipment will run normally and extend its life in use, maintenance and
preservation of equipment should not be neglected.
The warranty period of this equipment and
fittings could be seen in the detailed provisions of the contract of sale.
If the responsible hospital or unit using the equipment fails to realize maintenance and
preservation, unexpected equipment malfunction may occur and then bring the damage to health.
If you find any problems of equipment and need to get circuit diagrams, drawings, notes, or
technical support, please contact with maintenance personnel, Vita-Course Technologies or your
authorized supplier.
6.1. Cleaning of equipment
The equipment should be kept clean. It is recommended to clean the outer surface and display
screen regularly and in a timely manner using non erosion cleaning liquid, such as clean water. The
surface of the equipment and sensors can be cleaned by medical alcohol, dried naturally or cleaned
with dry cloth
 You must turn off the power before cleaning equipment.
Do not let the cleaning liquid be into connecting socket of the equipment in order to avoid
damaging the equipment.
Do not let any part of the equipment be soaked in the liquid.
After the use, please keep it clean and put it away.
Do not use such things that have strong friction (such as steel wool and sandpaper) to clean
the equipment.
Do not use such things that have strong corrosiveness such as bleaching powder to clean the
equipment and accessories.
6.2 Cleaning of accessories
After the use of accessories, you could immerse the clean and dry gauze in medical alcohol with the
concentration of 75% or in isopropanol solution with the concentration of 70% and then use this
gauze to clean the surface of the used accessory (including sensor and plug).
 Do not fully immerse accessories of the equipment in water solution, accessories or detergents.
6.3. Maintenance test
6.3.1 Routine test
Before using the equipment, you need to carry out the following inspection:
 Check whether the host has any mechanical damage;
 Check whether the structure performance of all accessories (including plug and sensor) is
complete;
 Check all available measurement function to make sure that the equipment can work well;
If there is any obvious indication of the damage of the equipment, please stop using it and
contact with supplier.
6.3.2 Periodic test
Every year or after the maintenance every time, a thorough inspection, including function and safety,
of the equipment must be carried out by qualified personnel.
 If y the hospital using the equipment cannot implement a satisfactory maintenance project, it will
result in equipment failure, and may endanger the health of human body.
 If the pulse wave sensor and the cable are damaged or deteriorated, stop using it and replace new
cables.
6.3.3 Battery maintenance
 This equipment adopts the built-in battery, which cannot be arbitrarily removed from it;
 Does not charge the battery using other power device, so as not to damage the battery;
 The aging battery cannot be thrown away in the fire, so as to avoid the explosion;
 Do not use the battery to supply power for other electronic devices;
 Destruction of battery should comply with local laws and regulations;
In order to extend the useful life of battery, please use battery properly and regularly carry out the
maintenance and preservation. The equipment should be charged regularly for maintenance though
it is not used for a long time. Generally, it should be charged once a month and 4~6 hours each time;
Please contact with our company directly if battery is already broken;
 This equipment is equipped with a built-in battery. Regardless of whether the boot for the use, as
long as alternating current (AC) is connected with the equipment, the process of charging is working.
When the battery is full, please disconnect the AC because charging time should not exceed 12
hours;
 Please use the power adapter configuration provided by our company.
Chapter 7 Storage and Transportation of Equipment
7.1 Storage
If the equipment is not used for a long time, it should be cleaned, put into the packing box and
stored in a dry, dust-free, and well ventilated room without corrosive gas.
7.2 Transportation
It can be transported by car, train or plane. Take care to handle gently during transit.
Environment of transportation and storage:
Temperature: -20 ~ 55 DEG c;
Relative range of humidity: 10%~ 95% (non condensing);
Range of atmospheric pressure: 53 kPa to 106 kPa.
Chapter 8 Troubleshooting
8.1 Check the equipment and accessories
A visual inspection should be carried out before each use when the power is disconnected:
1. Check the outside of the equipment to see if it is clean and the general physical condition. Make
sure the outer skin is not broken, all parts are in place, and there is no dumping of liquid as well as
no signs of abuse.
2. Check whether all accessories (such as cables, sensors, sensory unit, etc.)
are in good condition. If
there is any sign of damage, please stop using it.
8.2 Check cable and charging line
1. Check whether the power plug and the power cord are damaged, and make sure the plug is fixed
and not moved in the outer skin. If there is any damage, please contact the maintenance personnel,
Vita-Course Technologies or your authorized supplier.
2. Check the user's cable and its corresponding stress relief device in general to confirm that the
insulating layer is undamaged and that both ends of the connector are firmly connected to prevent
rotation or other stresses.
3.
Clamp the pulse wave sensor on the user's finger and open the equipment and gently pull the
cable line near the ends of the cable to make sure there is no interruption.
8.3 Troubleshooting
If you suspect a measurement results, please read the instruction manual and confirm several times
that the measurement is properly set.
If you have any problems with the equipment, please call the maintenance staff.
Phenomenon
Possible reason
Solution
The equipment is
Depletion of internal lithium
Plug in the power adapter to charge
power-off.
battery
the battery.
Possible damage
Send the product to the designated
repair shop or sales shop for repairs
No reaction
when pushing
Work abnormally
The equipment turns off if you push
button no less than 10 seconds; it will
the button
turn on if you push button about 1
second.
Figure 8.3 analysis of common fault
8.4 Disposal of equipment
In order to avoid the pollution and infecting others, other equipment and environment, the
equipment should be cleaned before the disposal of equipment and according to local regulation
(regulations on disposal of electronic and electrical components and equipment) it can be disposed.
If there is no related regulation, please dispose of it in accordance with the rules of the disposal of
waste in the local hospital.
Do not throw away battery randomly and knock it down, and then contact with the local supplier.
This product must be recycled and processed in accordance with local law.
Please do not treat obsolete electrical or electronic equipment as unclassified municipal waste.
Collected separately, the equipment can be safely, properly reused, treated, and recycled.
Chapter 9 Appendix
Appendix
EMC manufacturer's statement and guidance
Electromagnetic compatibility
Note:

The equipment complies with IEC 60601-1-2:2014 standard and electromagnetic
compatibility requirements

The user shall install and use the equipment according to the electromagnetic compatibility
information provided by the random files.

Portable and mobile RF communications devices may affect device performance, so in order to
avoid strong electromagnetic interference, please keep away mobile phones and microwave
ovens.

The guide and detailed manufacturer's statement are in the appendix.

This device is bound by Bluetooth and APP software. Bluetooth operating frequency:
2.400~2.4835 GHz, radiation power: -20~4 dBm. Pay attention to the effect on the equipment
that is sensitive to.
Warning:

Equipment or systems shall not be accessible or stacked for use with other equipment. If it must
be approached or folded for use, it shall be observed and verified to be in operation under the
configuration used.

In addition to the regulated transducer and cable, the use of specified accessories, transducers,
and cables may result in an increase in equipment or system emissions or a decrease in
immunity.

The use of specified accessories, transducers, or cables in conjunction with equipment and
systems may result in an increase in equipment or system emissions, or a decrease in immunity.

Using the value that is below the minimum amplitude or minimum specified in this specification
may lead to inaccurate results.
Appendix:
The guidance and manufacture’s statement--electromagnetic emission
Users or buyers of the equipment should make sure that it is used in such following
electromagnetic environment:
Emission test
Conformity
electromagnetic environment–guidance
The device uses RF energy only for its internal
GB4824 RF emission
1group
functions. As a result, its RF emission is very low and
may not cause any interference to nearby electronic
devices.
GB4824
B type
RF emission
Gb17625.1
Inadequacy
Harmonic emission
The equipment is suitable for use in all facilities,
including homes and public low voltage power
grids connected directly to homes.
GB17625.2
Voltage fluctuation /
Conformity
scintillation emission
The guidance and manufacture’s statement–electromagnetic immunity
Users or buyers of the equipment should make sure that it is used in such following
electromagnetic environment:
Immunity test
IEC 60601 test level
Accord with level
Electromagnetic
immunity–guidance
The ground shall be wood,
Electrostatic
discharge
(ESD)
GB/T 17626.2
±6 kV contact
±6 kV contact
discharge
discharge
±8 kV air discharge
±8 kV air discharge
concrete or tile, and if the
ground
is
synthetic
covered
with
material,
the
relative humidity shall be at
least 30%.
EFT--electrical
+ 2kV to power line
fast transient
+ 1kV to input / output
GB/T 17626.4
line
The network power shall
±2kV to power line
GB/T 17626.5
the commercial or hospital
environment.
+ 1 kV differential
Surge
have typical quality used in
The network power shall
mode voltage
±1 kV differential
have typical quality used in
+ 2 kV common mode
mode voltage
the commercial or hospital
voltage
environment.
<5 % UT, continuing 0.5
weeks
(on UT, a temporary
drop
Voltage sags,
short interru
ptions and vo
ltage variatio
ns on the po
wer input line
GB/T 17626.1
>95%)
40 % UT, lasting 5
weeks
(on UT, a temporary
drop
60%)
70 % UT,lasting 25
weeks
(on UT, a temporary
drop
30%)
<5 % UT, lasting 5s
(on UT, a temporary
drop
>95%)
<5 % UT, lasting
0.5 weeks(on UT, a
temporary
drop
>95%)
40 % UT, lasting 5
weeks(on UT, a
temporary drop
60%)
70 % UT,lasting25
weeks(on UT a
temporary drop
30%)
<5 % UT, lasting 5s
(on UT, a
The network power shall
have typical quality used in
the commercial or hospital
environment.
If
the
equipment's users need to
run
continuously
power
outages,
recommended
is
during
the
equipment
powered
by
uninterruptible
an
power
supply or uses battery.
temporary
drop
>95%)
The power frequency
Power
magnetic field shall have
frequency
magnetic field
3A/m 50Hz
3A/m 50Hz
(50Hz)
the
characteristics in a typical
commercial
GB/T 17626.8
horizontal
or
hospital
environment.
Note: UT refers to AC network voltage before test voltage is applied.
The guidance and manufacture’s statement–electromagnetic immunity
Users or buyers of the equipment should make sure that it is used in such following
electromagnetic environment:
Immuni
IEC 60601
Accord
ty test
test level
with level
Electromagnetic immunity–guidance
Portable and mobile RF communications devices shall
not be used closer to any part of the equipment
(including the cable) than the recommended isolation
distance. The distance shall be calculated by the
formula corresponding to the transmitter frequency.
Recommended isolation distance
RF
3 Vrms
3 Vrms
conduct
150 kHz to
d = 1.2 P
ion
80 MHz
d = 2.3 P
GB/T
d = 1.2 P
80 MHz to 800 MHz
800 MHz to 2,5 GHz
Among them, P refers to the maximum output power
17625.6
3 V/m
3 V/m
80 MHz to
rating of the transmitter, which is provided by its
manufactures. Watt (W) is a unit, D is recommended
isolation distance, and meters (m)is a unit.
RF
2,5 GHz
The field strength of the fixed RF transmitter is
radiatio
determined by the electromagnetic field survey a, and
in each frequency range the B should be lower than
GB/T
the level required.
17626.3
Interference may occur near the equipment that
marks the following symbols.
Note 1:On the 80MHz and 800MHz, formulas of higher frequency bands are employed.
Note 2:The guidance may not apply to all the situations because electromagnetic transmission is
influenced by the absorption and reflection of buildings, objects, and the human body.
The field strength of the fixed transmitter, such as wireless (cellular / cordless) telephone, the
base station of ground mobile radio, amateur radio, AM as well as
FM radio and television
broadcasting, cannot be theoretically predicted. In order to evaluate the electromagnetic
environment of a fixed RF transmitter, the investigation of electromagnetic field should be
conducted. If the field strength of the device is higher than the RF level of the above-mentioned
application, the equipment shall be observed to verify its normal operation. If abnormal
performance is observed, supplementary measures may be necessary, including reorientation or
repositioning of the equipment.
In the whole frequency range of 150 kHz to 80 MHz, the field strength should be less than 3 V/m.
Recommended isolation distance between portable and mobile RF communications devices and
Discovery 1
The device is expected to be used in a controlled electromagnetic environment where radiated RF
is disturbed. On the basis of the maximum output power of communication equipment, purchasers or
users of Discovery 1 can maintain the minimum distance between Discovery 1 and portable and mobile
RF communication equipment (transmitter) and accordingly prevent electromagnetic interference.
Rated maximum
output power of
transmitter /W
Isolation distance corresponding to different frequencies of transmitter
150 kHz ~ 80 MHz
d = 1.2 P
80 MHz ~ 800 MHz
800 MHz~ 2,5 GHz
d = 1.2 P
d = 2.3 P
0.01
0.12
0.12
0.23
0.1
0.38
0.38
0.73
1.2
1.2
2.3
10
3.8
3.8
7.3
100
12
12
23
Rated maximum output power of transmitter can be defined by related formulas of transmitter
frequency bar. Recommended isolation distance could be represented by d and the unit is meter. P
represents Rated maximum output power of transmitter, which is provided by its manufactures. Watt
(W) is a unit.
Note 1: on a frequency range of 80 MHz and 800 MHz, a formula with a higher frequency range is
adopted
Note 2:The guidance may not apply to all the situations because electromagnetic transmission is
influenced by the absorption and reflection of buildings, objects, and the human body.
The warranty ordinance of the product
1. Product warranty card is a certificate of warranty service;
2. The warranty period of the host of the equipment is 1 year and of battery and other
accessories is 3 months. The warranty start date is the invoice purchase date.
3. Due to the following circumstances, product failure does not belong to the warranty
category.
1) Users disassemble, refit products and use other accessories that are not provided by the
company;
2) Machine failure or damage because users do not obey the safety or operating method described
in this specification;
3) Damage caused by improper use or other factors, or by natural disasters.
4. if the repair service is beyond the warranty range, the maintenance would not be free and the
warranty period of the same failure lasts 3 months.
Warranty card
Users’ information
Name of the
equipment
Type of the
equipment
Number of the
equipment
Purchase date
Users’ name
Telephone
Warranty record :
Warranty date
Failure and
processing method
Repairer /date
FCC Caution
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
Any Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
Environment and can be use without any restrictions.
Contact information
Manufacturer: Vita-Course Technologies (Hainan) Co., Ltd.
Registered address:A5002, A1, Fuxing District, 32 Binhai Avenue, Longhua District, Hainan,
Haikou Province
Production address:The first floor of the East of the office building of Hainan Newway
Pharmaceutical Co., Ltd., Nanhai Road, Hainan City
Phone: 0898-66701808
Fax:
0898-66707808
E-mail: vita@vita-course.com
WeChat public number:维他驿站
Registration number / technical requirement number:
Production license number:
Product life: 3 years
Production date: detailed information in the host nameplate

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 33
Language                        : zh-CN
Tagged PDF                      : Yes
Author                          : liwei wang
Creator                         : Microsoft? Office Word 2007
Create Date                     : 2018:04:09 16:45:40+08:00
Modify Date                     : 2018:04:09 16:45:40+08:00
Producer                        : Microsoft? Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AO9A-DISCOVERY

Navigation menu