*P516-961*

6300

P516-961
Surface Mounted Rim Strike

Installation Instructions

3

Important:
Installations of the RIM strike qualify as “Indoor Use Only” when
not continuously exposed to an outdoor environment. Ensure
the exit device functions as intended for life safety concerns by
verifying electric strike and exit device compatibility. Maximum latch
projection is essential to obtaining full holding force.
When installed in a fail secure manner, the local authority having
jurisdiction shall be consulted with regard to the use of selected
panic hardware to ensure emergency exit from the secured area.
Catalog specifications
Model
6300
6300

Mode
Fail Secure
Fail Secure

Voltage
12V
24V

Current
DC
DC

Duty
Continuous
Continuous

Amps
0.50
0.24

Ohms
22
89

FSE = Fail Locked / Fail Secure
DC = Direct Current
Continuous Duty = Energized 1 minute or more

1³⁄₄"
(44.5mm)

Drill and tap the two mounting holes and drill the wire access hole

4

³⁄₄"
(19.0mm)

Test fit

Test fit electric strike to ensure full latch engagement. Add provided
spacer if required

5

Wire connections

Make wire connections from the power source to the appropriate
wire harness supplied. Use the 12V harness for 12VDC. Use the
24V harness only for 24VDC
LL Note: Overheated or burnt coils caused by incorrect
voltage/wire harness combinations will not be covered
under warranty

6

Dimensional Details

Drill and tap

Mount electric strike

Using the Z\v-20 UNC screws provided, loosely mount the electric
strike using the horizontal mounting holes (outer slots)
Door Frame Stop

Horizontal
adjustment
mounting holes
1⁵⁄₈"
(42.0mm)

9"
(228.6mm)

³⁄₄" (19mm)
Wire access hole

5¹⁄₂"
(139.7mm)

8¹⁄₄"
(209.6mm)

¹⁄₄-20 UNC
(2 places)

Lockdown
holes

1

Find center line

Determine the horizontal center line of the exit device latch and
transfer center line to the frame stop

2

Center-punch mounting holes

Position the paper template onto the frame aligning with center line
and against the closed door. Center-punch the two mounting holes
and the wire access hole as shown

! NOTE:
Wire access
hole location
is relative to
the exit device
orientation.

Mounting
Screw
(2 places)

7

Install Exit Device

Install exit device per manufacturer instructions and align plastic
template as shown

³⁄₁₆"
WARNING: For proper operation,
a ³⁄₁₆" gap (minimum) is required.
99 Rim
template shown

8

Adjust strike

Adjust the electric strike horizontally until exit device latch fully
engages with the door closed
LL Note: Ensure a Z\zn" (1.5mm) clearance between exit device
latch and electric strike is maintained. Latchbolt should
not touch the keeper

9

Check screws and operation

Tighten the two mounting screws and check operation. Adjust the
horizontal position of the electric strike as required

10

Prepare holes

Using the electric strike as a template, prepare the two locking
holes by drilling and tapping for Z\v-20 UNC screws. Using the Z\v-20
UNC screws provided, secure the electric strike through the locking
holes

Locking Screw
(2 places)

Door Frame

11

Check Proper Electrical and Mechanical Function

Customer Service
1-877-671-7011

www.allegion.com/us

© Allegion 2014
P516-961 Rev. 07/14-a



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2014:07:02 15:21:28-06:00
Creator                         : Adobe InDesign CS6 (Windows)
Modify Date                     : 2014:10:10 13:45:34-04:00
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2014:10:10 13:45:34-04:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:bf466428-2cca-4fee-a3f9-2820d0a2cdbf
Original Document ID            : xmp.did:516915126ECCE1118A0D8AD340C27D6B
Document ID                     : xmp.id:CBB218AE2E02E4119A0BE2357EC04A6E
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:CAB218AE2E02E4119A0BE2357EC04A6E
Derived From Document ID        : xmp.did:47A44EA0A139E21197309D1C525C39AC
Derived From Original Document ID: xmp.did:516915126ECCE1118A0D8AD340C27D6B
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2014:07:02 15:21:28-06:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu