911373-00
Rim Exit Device

Installation Instructions

#10-24

Dogging Key
(use to lock down pushbar)

Customer Service
1-877-671-7011

www.allegion.com/us

© Allegion 2014
Printed in U.S.A.
911373-00 Rev. 05/14-f

SCREW CHART
Screw

Device Subassembly

299 Strike

Application

#10-24 x ³⁄₄” (19 mm)

Metal frame

#10 x 1¹⁄₂” (38 mm) Wood screw

Wood frame

#10-24 x 1” (25 mm)

Surface mount or Sex bolts
1³⁄₄” (44 mm) door

#10-24 x 1¹⁄₂” (38 mm)

Sex bolts, 2¹⁄₄” (57 mm) door

#10 x 1¹⁄₄” (32 mm) Wood screw

Surface mount (wood)

#10-24 x 1³⁄₈” (35 mm)

1³⁄₄” (44 mm) door, 990 Trim

#10-24 x 1⁷⁄₈” (48 mm)

2¹⁄₄” (57 mm) door, 990 Trim

#10-24 x ³⁄₄” (19 mm)

Surface mount or Sex bolts
1³⁄₄” (44 mm) door

#10-24 x 1¹⁄₈” (29 mm)

Sex bolts, 2¹⁄₄” (57 mm) door

#10 x 1¹⁄₄” (32 mm) Wood screw

Surface mount (wood)

#10-16 x ³⁄₈” (10 mm) Thread cutting

End cap

#10-24 x 1” (25 mm)

Surface mount (metal)

#10 x 1¹⁄₄” (32 mm) Wood screw

Surface mount (wood)

#8-18 x ³⁄₈” (10 mm) Thread cutting

Center case cover

499F Strike

Packaged with 990 Trims:

2

1

Draw horizontal device and strike center lines (CL ).

3

Prepare 2 holes and install 2 screws.

Q See “Screw Chart” on previous page for screw types and
sizes

* 39¹³⁄₁₆” (101.1 cm)
from finished floor
RHR

RHR

LHR

* For double doors with a
mullion and strike already
installed, use existing
strike center line.

Metal

#10-24

#25

OR

2

Wood

Align strike on CL and mark the two slotted
holes.

Q For 499F strike installation, see page 6.

4

¹⁄₈” (3 mm) x 1” (25 mm) deep

Position template against strike and on C
L and
mark door.

Roller
(against door)
299
OR

Mark Vertical CL

299F

Mark 6 holes

Q For more information on the strikes shown below, go to
http://w3securitytechnologies.com and look for the
Support area for Von Duprin installation instructions.

5

If necessary, prepare cutouts for cylinder and trim.

RHR shown, LHR opposite
1439

1609

For outside cylinder applications:
Mark with template and cut out
264

1606

Metal door (cut device side)
Wood door (cut thru)

For trim applications
with working lever,
thumbpiece, or knob:
Mark with template
and cut out (cut
device side only)
3

6

8

Prepare 4 center case mounting holes.

If necessary, remove NL drive screw

NL drive screw
Factory installed on
back of center case

Four mounting holes

With the NL drive screw removed, key locks and unlocks lever, knob, or
thumb piece. For the trims listed below, REMOVE NL drive screw.
996L
996K

696TP
697TP

990TP

With the NL drive screw installed, key retracts latch bolt. DO NOT remove
NL drive screw for the following applications:

See trim instructions
for pull side door
preparation. Line X-X in
trim instructions is same
as vertical device CL.

#10-24
¹⁄₈” (3 mm) x 1” (25 mm) Deep

7

SEX BOLTS or 990 TRIMS

OR
METAL

#25

*996L-BE
*996K-BE

WOOD

*E996L
*E996L-BE

*696TP-BE
*697TP-BE

*990TP-BE

* If the trim being installed is "BE" (i.e. 996L-BE), the trim lock tumbler
on the back of the device must be in the UP position before device
is installed. This allows the trim to be unlocked at all times.

¹⁄₄” (6 mm) Device Side
¹³⁄₃₂” (10 mm) Trim Side

trim lock
tumbler in
UP position

¹³⁄₃₂” (10 mm) Drill Thru

Correct
Orientation
(RHR shown)

Prepare 2 center case support holes.

Two support holes

If necessary,
remove drive
screw and
rotate cam
until trim lock
tumbler is in
UP position,
then reinstall
drive screw

360˚
Incorrect
Orientation

9

If using a cylinder with a tailpiece, prepare device
and cylinder.

9a

Install tailpiece guide.

Tailpiece guide
Tailpiece
OR WOOD
98/99

METAL
98/99 and 98/99-F

¹⁄₈” (3 mm) x 1” (25 mm) Deep

Rotate tailpiece guide
to match tailpiece

#25
#10-24

98/99-F
#825 Sex bolts (2) required
¹⁄₁₆” (2 mm)

³⁄₈”
(10 mm)

9b

Cut tailpiece as needed.
¹⁄₂”

Exterior

⁵⁄₁₆” (16 mm)

Door
Surface

WOOD

METAL

SURFACE MOUNT

NL, EO, DT trims and 98/99-2 double cylinder devices (i.e. TP-2,
L-2, and K-2).

4

10

12

If necessary, cut device.

Mark and prepare two (2) holes.

a

SURFACE MOUNT

WOOD

1¹⁄₂” (38 mm)
recommended

hinge side is leveled.

METAL

Jamb

Jamb

Q Prepare holes after lock side of device is mounted and

#25
#10-24
¹⁄₈” (3 mm) x 1” (25 mm) Deep

OR

Temporarily remove
anti-rattle clip

WOOD

b

METAL

SEX BOLTS
¹⁄₄” (6 mm) Device Side
¹³⁄₃₂” (10 mm) Trim Side
¹³⁄₃₂” (10 mm) Drill Thru

Cover plate flush

11

c

Attach center case to door.
Thru-Bolting Trim

13

Install end cap bracket and end cap.

OR

Surface Mount

Sex Bolts

5

14

15

Install required support screws and
center case cover.

Adjust strike as needed.
Shim as needed

299/299F Strike

Remove protective
film from pushbar

³⁄₁₆” (5 mm)
299

299F

16

Install strike support screw.

OR

METAL

WOOD
#25

¹⁄₈” (3 mm) x
1” (25 mm) Deep

#10-24

499F STRIKE INSTALLATION

#25 Drill
#10-24 Tap
2 places

Metal
Roller
(against door)

2. Install strike hook and additional strike
screws.
#7 Drill
¹⁄₄” (6 mm)20 Tap
2 places

Wood

1. Prepare and install screws through two
strike slots.

¹³⁄₃₂” (10 mm)
Drill thru for
sex bolts
2 places

3. Template aligns as shown.

Template
(align on CL and
against strike

#25 Drill
#10-24 Tap
3 places

Q If using a mullion,
holes may be predrilled

6

OPTIONAL EQUIPMENT
CD (Cylinder Dogging) Option

a

c

d

f

b
e

Dog

Undog

7

OPTIONAL EQUIPMENT
99-2 (Double Cylinder) Option
Door Cutout for 99-2 “Double Cylinder” Option
#8-18 x ³⁄₈” (10 mm)
PPHSMS
Wood
¹⁄₄” (6 mm)
Deep
#8-32 x ⁵⁄₁₆” (8 mm)
PPHMS

⁵⁄₈” (16 mm)

e
1³⁄₄” (44 mm)

c

d
b

Cylinder
Mounting Screws
DO NOT over-tighten

1¹⁄₄”
(32 mm)

¹⁄₈” (3 mm) R
4 places

a
RHR Shown
(LHR opposite)

1³⁄₈” (35 mm)

Device
and Strike
Door Cutout for 99-2SI “Double Cylinder” Option

Wood
¹⁄₄” (6 mm)
Deep
2¹⁄₄” (57 mm)

If using the -2SI with a
keyed rim cylinder,
remove the 2 stop screws
from back of device prior
to installing the cylinder.

¹⁄₈” (3 mm) R
4 places

1⁵⁄₈”
(41 mm)

¹³⁄₁₆” (21 mm)

1³⁄₈” (35 mm)

Device
and Strike

For 98/99-2SI models with Classroom Security Indicator, apply supplied labels above and below cylinder to match door handing,
and
label on indicator.

99-2 LHR

99-2 RHR

Peel and stick
appropriate set of
labels depending on
door handing. Stick labels
above and below cylinder,
and
label on indicator.

Q Manually affix the label:
Ensure surface is clean of dirt, dust, or oils. Clean with alcohol
if necessary.
Peel the label from the paper backing and apply to the surface.
Minimize handling when applying and use pressure to burnish
label to surface. The adhesive will require up to 8 hours to
achieve the proper bond.

RHR shown

8



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : jtellis
Create Date                     : 2014:05:23 12:03:56-04:00
Modify Date                     : 2014:05:23 12:03:56-04:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 10.1.7 (Windows)
Format                          : application/pdf
Title                           : 911373-f.indd
Creator                         : jtellis
Document ID                     : uuid:b5132f3b-ba5a-4b73-954b-6b1208f8ace9
Instance ID                     : uuid:b344212e-4867-4c2e-9df1-2fcf341d2523
Page Count                      : 8
EXIF Metadata provided by EXIF.tools

Navigation menu