General Information
These instructions are presented in step-by-step sequence.
Review this page carefully. It will help identify the hardware and define the terminology used throughout.

Parts List


Note: The ALK Alarm Kit requires an RX or LX switch mounted in the exit device.

This kit includes the following parts (shown below):
• ALK Unit
• Emergency Exit Sign
• Cylinder Collar
• 9 Volt Battery

ALK Unit
(faceplate shown)

2

Emergency Exit Sign
(packed in cardboard tube)

Cylinder
Collar

9 Volt
Battery

Installation

1

Assemble the ALK unit with the parts in order as shown below,

A

through

G.
Remove
and
discard

Do not allow
pieces to slip out

A 11/4" Mortise
cylinder

Make sure
polarity
is correct
B Cylinder
collar

C Cylinder bracket
D Cylinder spacer
9 volt battery G
Cylinder nut F

E

Cam should be in
OFF position before
battery is installed

Push leaf spring
behind retaining
pin if needed

3

2


Cut the device and/or cover plate (end opposite cylinder hole) to proper length.
Note: See device installation instructions for additional information.

Cut this end

Minimum cover plate
length is 8-7/8"

3


4

If exit device does not have LX or RX switch in it, install switch before proceeding.
Note: Refer to the appropriate RX or LX installation instructions.

Remove the exit device end cap and dogging cover.

End cap
Dogging cover

4

5

Attach wiring to terminal blocks on ALK board as shown.

Notes about Wiring:
The EI (external inhibit) option uses NO (normally open) dry access control contacts to inhibit the ALK.
Closing the access control contacts inhibits the ALK. When the access control contacts are re-opened, the ALK re-arms with no delay.
RX, LX, and EI inputs are not polarized.

Von Duprin 24 VDC
Power Supply
(Polarity Sensitive Input)
Insulate unused wire

RX Switch
Yellow
Red
Blue

24VDC
RX/LX SWITCH
TB1
EI
NC

TB2

C
NO

OR

EPT 10
Insulate unused wire

LX Switch

The current draw of a Von
Duprin exit alarm ALK is .25
amp when alarm is activated.

Violet
White

EI
NO (normally open)
Access Contol
Contacts

Gray

6

Adjust alarm reset time, as needed.

Adjust dip switches as shown below to adjust reset time.
S2.2

S2.1

Reset

OFF

OFF

NONE

ON

OFF

1.5

OFF

ON

3

ON

ON

4.5

5

7


Remove dogging shaft if present and slide ALK unit into device.
Note: Make sure that the wires do not tangle with moving parts by carefully pulling them toward the dogging end of device
while sliding in the ALK unit.

ALK assembly
Remove label

Remove dogging
shaft if present

6

8

Install device to door.

9

Mount sign by peeling off protective backing and sticking sign into place.

Operating Instructions
1. Insert the key into the cylinder and arm the unit by turning the key clockwise to position B until it stops. Return key to position
to remove. There is a 15 to 20 second delay before arming during which the LED will flash every 3 to 5 seconds.

A

2. Observe the LED. After the 15-20 second delay has passed, the horn will sound briefly and the LED will flash every 12 to 15 seconds.
This indicates that the ALK is now in armed mode.
3. Turn the key counterclockwise to position

C

to disarm.

TO DISARM

TO ARM
RHR Shown
(LHR opposite)

C

A

A
Push to test

B

RHR Shown
(LHR opposite)

7

Changing the Battery
If the battery is low, a beep will sound and LED will flash every 35 to 40 seconds until the battery is changed. This beeping cannot be
stopped by disarming the unit.
To change the battery, follow steps

A

through

C

below, then reassemble.

A Remove end cap

Slide out ALK assembly B

Make sure
polarity
is correct

Change battery C

Customer Service
1-877-671-7011

www.allegion.com/us

© Allegion 2015
Printed in U.S.A.
941042-00 Rev. 07/15-f



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : jtellis
Create Date                     : 2015:07:01 13:22:20-04:00
Modify Date                     : 2015:07:01 13:22:20-04:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Producer                        : Acrobat Distiller 11.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Title                           : 941042-00_f.indd
Creator                         : jtellis
Document ID                     : uuid:c1f2d6f2-16e2-4271-b335-d4e87b72d9d2
Instance ID                     : uuid:39df5d29-fd17-43ec-8288-aa7ac808bd38
Page Count                      : 8
EXIF Metadata provided by EXIF.tools

Navigation menu