Von Duprin 941042 00_f 33/35/98/99 ALK Kit 107710

User Manual: Von Duprin 33/35/98/99 ALK Kit Installation Instructions

Open the PDF directly: View PDF PDF.
Page Count: 8


941042-00
Index:
General Information .................. 2
Parts List ................................... 2...................................
• Installation................................ 3
Operating Instructions .............. 7
Changing the Battery ................ 8
Wiring ...................................... 5
ALK Alarm Kit
33/35 and 98/99
Installation Instructions
2
General Information
These instructions are presented in step-by-step sequence.
Review this page carefully. It will help identify the hardware and de ne the terminology used throughout.
Parts List
Note: The ALK Alarm Kit requires an RX or LX switch mounted in the exit device.
This kit includes the following parts (shown below):
• ALK Unit
Emergency Exit Sign
• Cylinder Collar
9 Volt Battery
ALK Unit
(faceplate shown) Emergency Exit Sign
(packed in cardboard tube) Cylinder
Collar 9 Volt
Battery
3
Installation
1 Assemble the ALK unit with the parts in order as shown below, A through G.
Cylinder
collar
B
Cylinder bracket
Cylinder spacer
A11/4" Mortise
cylinder
C
D
F
9 volt battery G
E
Remove
and
discard
Make sure
polarity
is correct
Push leaf spring
behind retaining
pin if needed
Cam should be in
OFF position before
battery is installed
Cylinder nut
Do not allow
pieces to slip out
4
2 Cut the device and/or cover plate (end opposite cylinder hole) to proper length.
Note: See device installation instructions for additional information.
Cut this end
Minimum cover plate
length is 8-7/8"
3 If exit device does not have LX or RX switch in it, install switch before proceeding.
Note: Refer to the appropriate RX or LX installation instructions.
4 Remove the exit device end cap and dogging cover.
Dogging cover
End cap
5
5 Attach wiring to terminal blocks on ALK board as shown.
Notes about Wiring:
The EI (external inhibit) option uses NO (normally open) dry access control contacts to inhibit the ALK.
Closing the access control contacts inhibits the ALK. When the access control contacts are re-opened, the ALK re-arms with no delay.
RX, LX, and EI inputs are not polarized.
Yellow
Red
Blue
Violet
White
Gray
Von Duprin 24 VDC
Power Supply
(Polarity Sensitive Input)
RX Switch
LX Switch
OR
Insulate unused wire
Insulate unused wire
24VDC
EPT 10
EI
NO (normally open)
Access Contol
Contacts
EI
TB2
TB1
RX/LX SWITCH
NC
C
NO
The current draw of a Von
Duprin exit alarm ALK is .25
amp when alarm is activated.
6 Adjust alarm reset time, as needed.
Adjust dip switches as shown below to adjust reset time.
S2.2 S2.1 Reset
OFF OFF NONE
ON OFF 1.5
OFF ON 3
ON ON 4.5
6
7 Remove dogging shaft if present and slide ALK unit into device.
Note: Make sure that the wires do not tangle with moving parts by carefully pulling them toward the dogging end of device
while sliding in the ALK unit.
Remove dogging
shaft if present
ALK assembly Remove label
7
8 Install device to door.
9 Mount sign by peeling off protective backing and sticking sign into place.
Operating Instructions
1. Insert the key into the cylinder and arm the unit by turning the key clockwise to position B until it stops. Return key to position A
to remove. There is a 15 to 20 second delay before arming during which the LED will ash every 3 to 5 seconds.
2. Observe the LED. After the 15-20 second delay has passed, the horn will sound brie y and the LED will ash every 12 to 15 seconds.
This indicates that the ALK is now in armed mode.
3. Turn the key counterclockwise to position C to disarm.
A
B
C
A
RHR Shown
(LHR opposite)
RHR Shown
(LHR opposite)
TO ARM TO DISARM
Push to test
© Allegion 2015
Printed in U.S.A.
941042-00 Rev. 07/15-f
Changing the Battery
If the battery is low, a beep will sound and LED will ash every 35 to 40 seconds until the battery is changed. This beeping cannot be
stopped by disarming the unit.
To change the battery, follow steps A through C below, then reassemble.
A Remove end cap
Slide out ALK assembly B
Make sure
polarity
is correct
Change battery C
Customer Service
1-877-671-7011 www.allegion.com/us