WENZHOU MTLC ELECTRIC APPLIANCES MWS Receptacle User Manual USERS MANUAL

WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD. Receptacle USERS MANUAL

USERS MANUAL

SPECIFICATION-01- -02- -03- INSTALLATION INSTRUCTIONS Smart AC Switching Control ReceptacleVoltage(MWS-120)............................................................120VAC,60HzWireless Transmitting current.........................................................40 mAMax Wireless Range(direct)................................................within 20 feetmeets all the fire and building codeas a receptacle for air conditioner , electric heater,  and fan coil for air Smart Decorator Duplex Receptacle conditioning . It receives and processes  signals from transmit device, make and break the circuit base on occupancy or vacancy of the room.MWS-120,MWS-240Voltage(MWS-240)............................................................240VAC,60HzLoad Rating........................................................................................20AOperating temperature........................................................30°F to 120°F Relative Humidity........................................20% to 90% non-condensingOperating Frequency...................................................................315MHzReception Sensitivity..................................................................-105dBmFlush mount 20A Smart ReceptacleConstant System Self TestingFEATURE COMPONENTS(MWS-RSC-120, and MWS-RSC-240)Installation : Connect Hot Line wire to Black screw terminal,Neutral to White screw Terminal, Ground to Green screw terminal.DESCRIPTIONThis flush wall mount wiring device MWS-120 MWS-240120 Vac SmartReceptacleFigure 1Function ButtonIndicatorControlled ReceptacleFunction ButtonIndicator240 Vac SmartReceptacleControlled ReceptacleSide wired onlyHave code function to ensure the uniqueness of device control One controlled receptacle Both are tamper resistant receptacles Energy is the basic power for ensuring the working of all machines.Tosave energy and decrease the daily consumption means that the oper--ation cost will be reduced and the profit will raise. The air conditioner’s energy consumption takes up a majority of the total energy consumption.Therefore s set of energy-saving air conditioning control system is fairly The air conditioning auto control system is made up of three parts: two transmit devices and one receive  smart receptacle, each of which the receptacle in a singleoff, then can save   Factory Default:TESTINGWarming Up:After  connecting  power  to  Smart Receptacle , there are 40 seconds warming up time.When both LEDs  of Smart Receptacle and transmit devices flash twice.If not, go to Code Learn Mode.Self Test Mode:Push  the  Function button  on Smart Receptacle  only  once, LED blinks once , the system is now  Self Test mode, do not plug in the load at this time.  LED  blinking  rapidly,  solid  On and  Off .  After 5 minutes , LEDbecomes solid On , Self Test Mode is finished. If LED is off at this time,  open or close the door ,LED turns On.Make sure transmit device is not detecting anyone, close and open the Confirming Test:door , keep  the  door  open for the  next 15  minutes , LED  turns Off  between 10 to 15 minutes.Test complete.CODE LEARNING MODEThe codes are factory preset in a package. However, if there is a need of code match, push the Function  button for more will  become  blinking,  in the next  30 seconds,  transmit  device's LED turns solid,code is matched.Note: once a new code in , the old code will  be  erased  in the Smart receptacle.essential.communicates wireless with   room, to control energy and makethe air conditioning auto on/auto the air conditioner more intelligent.than 5 seconds, LED TROUBLE SHOOTINGLED on Receptacle keep flashing:Run Self Test Mode, if end of batteries , replace them.Power Off 15 minutes even if occupancy:RF signal is blocked from the transmit device to the receptaclePower On 10-15 minutes even if vacancy:RF signal is blocked from the transmit device  to the receptacleReceptacle can not recognize signals from Sensor:Refer to  the CODE LEARNING MODE.Our  company  warranties its products to be free of defects in  materials and workmanship for a period of two (2) years. There are no obligations or  liabilities  on  the  part  of our  company for  consequential  damages arising out of or in connection with the use or performance of this product or other  indirect  damages with respect to loss of property,  revenue , or profit ,or cost of removal, installation or reinstallation.Feb,2012WARRANTY INFORMATION
 FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.

Navigation menu