1413Add ConnectionIf you choose Microsoft RDP, “WTS (Windows Terminal Server) ConnectionWizard” appears as follows. “WTS Connection Wizard” begins as you click “AddConnection” and you have to fill out two pieces of information.Name : This is the name of connection assigned by the user. It is convenientto use names such as “Operation Server” or “Production Server”which are easy to remember.Server : This is the address of the server such as “www.sales.com”  or“123.456.789.012.”RDP connection wizardPlease ask the Server/Service manager.If you click “Add” button, the following dialogue window appears so that you canchoose the type of connection. As for the types of connections supported by theserver, please ask the server/service manager.Adding new connection
1615Automatic Execution of Application ProgramsThe user can choose the application program to be executed as soon as the terminalis connected to server/service. If “Desktop” is chosen, the regular background screenof Windows NT/Windows 2000 appears. If an application program is chosen, theprogram is directly executed at the startup. In this case, the user must specify the pathof the application program.Finishing RDP Connection WizardIf you click the “Finish” button, the WTS Connection Wizard ends and the newconnection is added to the connection manager.Automatic Connection to Server/ServiceWhen automatic connection function is used, the user can be directly connected tothe server which is frequently used when the terminal is on. To use this function, thefollowing three data have to be typed.Username:  Username registered with the server/service.Password : The password of the user.Domain : The domain name of the server/service.Please ask the Server/Service manager.
1817Choosing Connection Name Connection name is given by the user. It is preferable to choose names such as“Operation Server” or “Marketing Server” which are easily remembered.Setting the Server ICA Connection Wizard is equipped with a function to display all the servers that canbe currently used by the network.Please choose the server to be used among the servers displayed or type the serveraddress yourself.Choosing the Connection MethodIn this section, the method for connection to the server/service is chosen. Ourterminal only supports “Network Connection.”You can choose the ICA Client at the “Terminal Connection Manager”.ICA connection wizardNetwork Connection : uses the direct connection line like LANConnection.Dial-in Connection     : uses the modem.
2019Choosing ColorsIn this section, the user chooses the number of colors to be used by the ICA client.Automatic Execution of Application ProgramsThe user can choose the application program to be executed when the terminal isconnected to the server/service. If the user does not specify the application program,the background screen of Windows NT/Windows 2000 appears. If an applicationprogram is chosen, the program is immediately executed. In this case, the locationof the application program must be given.Automatic Connection to the Server/ServiceIf the automatic connection function is used, the terminal is directly connected to thefrequently used server at the startup. To use this function, the following three datamust be typed.Username : Username registered with the server/service.Password : The password of the user.Domain     : The domain name of the server/service.
2221When you have finished adding new connection...If you have finished adding new connections by “RDP Connection Wizard” or “ICAConnection Wizard,” the following new connections are displayed. Therefore, fromnow on, you can double-click the connection to be used and you are connected to theserver and implement desired operations.Data Compression and SoundThe user chooses whether he/she will use the data compression function and thesound function with the ICA client.FirewallIf the firewall is installed at the Network, the user offers necessary information.Ask the Network manager.
24From the “Configure” screen of the Terminal Connection Manager, please choose theconnection to be deleted and click the “Delete” button. Then, the following “ConfirmConnection Delete” screen appears.Deleting connection23From the “Configure” screen of the Terminal Connection Manger, please choose theconnection to be changed and click the “Edit” button. The following is the screen thatappears.You can change “ICA” on the following screen and change details, as you click eachtab.Ask the Network manager.Changing connection
2625In this section, you decide the waiting time keyboard input and the repeat speed.In this section, you decide the display resolution, the volume size, etc.KeyboardScreen and volume7. Terminal SettingWhen “Terminal Connection Manager” is on the screen, press F2 key and thefollowing “Terminal Properties” screen appears and you can determine detailedaspects of the terminal. To end “Terminal Properties” and move to “TerminalConnection Manager” screen, press the “OK” button that is on the right side of thescreen. If the “X” button is pressed, all new settings are cancelled.This section involves various types of information on the product.If you choose “Reset the terminal to factory-default property settings” all settings ofthe terminal are deleted and you return to the “Terminal Installation Wizard.” Starting terminal settingProduct information
2827This section is for setting various options on the Network.If you choose “Specify an IP address” the “Advanced Network Settings” button isactivated. Then, if you press the “Advanced Network Settings” button, the followingscreen appears and you can offer necessary information.Ask the Network manager.Ask the Network manager.NetworkFrom the “Resolution & Frequency” list, you can choose the intended resolution andfrequency.  If you press the “Test” button, the following dialogue window appears.Press the “OK” button on the dialogue window and the terminal restarts at theresolution and frequency chosen. And the following dialogue window appears tocheck whether the monitor supports the resolution and frequency. If the followingdialogue window does not appear your monitor does not support the resolution andfrequency chosen. If you press the “PASS” button, the monitor is reset at the newresolution. If you press “FAIL” the monitor returns to the previous resolution.The following are the resolutions and frequencies supported by the terminal.If you choose “Use Screensaver,” the monitor is protected as the screensaver functionis executed if the terminal has not in use for a predetermined period.In addition, if you press the “Volume” button, it is possible to adjust the size ofvolume out from the terminal.640 X480     75Hz            800 X600     75Hz 1024 X768     75Hzaaa
3029In this option, you input the Terminal name and colors to be used at the “ICA ClientConfiguration” and choose colors  among 3 types(16, 256 and thousands of colors).It’s good to select a significant Client Name. The Client Name recognizes theTerminal at the network.In this option, you select the server that you want to connect. If you use LAN, youselect one from the server list that is displayed automatically. If you want to connectthe server that is not in the server list, press “ADD” button and input the DomainName or IP address.In this section, you indicate various items related to the system and set the basicconfiguration for the ICA client.From the “ICA Client Configuration” press “Configure” button and than thefollowing dialogue window appears. Now you can choose options wanted.This option is about Hot keys. They are defined on the Operating System or theapplication program. Also, the user can set them to activate a specific order.System
3231In this section, various items related to the web-browser are set.Press the “Preferences” button and the following dialogue window appears. Thedisplay method for hyperlinks and default font size can be decided.Web settingIf the SOCKS Proxy server is installed at the network, IP address of the Proxy serverhas to be typed. So you select the SOCKS Proxy server connection and input the portnumber and IP address of the SOCKS Proxy server.If the Nfuse server of Citrix Company is installed, various options related to theNfuse server have to be typed.
3433Press the “Change Password” button and the following dialogue window appears.Then it is possible to change the password. For verification, the password must betyped twice.When the password for terminal security is in place, press F2 key for “TerminalSetting.” Then the following dialogue window for password verification appears. Theuser must type the correct password to use the “Terminal Setting” function.Because the terminal cannot be reset if the password is lost, it is necessary to handle the password with care.If the “Proxy Information” button is pressed, the following dialogue window appearsand various items related to the proxy server can be set.Ask the Network manager.This section is for the setting of terminal security that is necessary to protect thecontents of various terminal settings. Press the “Change Password” button to changethe password for the terminal setting. If a password is in place, the contents ofterminal setting cannot be changed without typing the correct password.Terminal security
3635Key ProcessHot KeyBRIGHTNESS                           CONTRASTMENUStart8. OPERATION & ADJUSTMENT•Move cursor to the right window on the OSD window.•Increase the value of any selected function.•Move cursor to the left window on the OSD window.•Decrease the value of any selected  function.•Launch OSD(On-Screen Display) MENU window.•Move cursor to the high window on the OSD window.•Increase the value of V.size or V.center.•Move cursor to the low window on the OSD window.•Decrease the value of V.size or V.center.
3837Monitor9. SPECIFICATIONSNS Geode GX-1 233 MHz8/16M Flash Memory16/32M RAMMaximum Resolution 1024x768Maximum 16 bit ColorCD-level sound - 16 bit 44.1 KHz StereoExternal speakers - 1/8 inch mini-jackExternal microphone - 1/8 inch mini-jackBuilt-in speakers - 8 OHM 1.75 WPS/2 Type KeyboardPS/2 Type Mouse10/100 BaseT EthernetRJ-45 Connector2 PS/2 Port2 USB Port (Type A)1 RS-232C Serial Port (DB-9)1 Printer Port (DB-25)Microsoft Windows CE 2.12 (Including Direct X)Microsoft RDP ClientCitrix ICA ClientWin CE MS Internet Explorer 4.01Win CE MS Windows Media Player 6.4C P UMemoryVideoAudioKeyboardMouseNetworkI/O InterfaceSoftwareTerminal CDT Size 17-inchDiagonal visible image area 16.2-inchDot Pitch 0.28mm                         Synchronization Horizontal 30 - 70KHzVertical 50 - 160Hz Plug and Play DDC1/2B/CIPower Saving EPA, VESA DPMS, Nutek CompliantPower Source 100-240 Vac, 50/60Hz (Free Voltage)Power Consumption 85WDimension-W x H x D 420 x 440 x 440mm        (set with stand)Weight-unpacked 37.0/16.8(lbs/Kg)Operating Temperature 10 ~ 40°C /50 ~ 104°FUser Control Contrast(Hot Key)Brightness(Hot Key)H/V Size, H/V Center, Pincushion, Trapezoid,Temperature, Pin Balance, Parallelogram,Pin Corner, RGB Gain, Status, Degauss, H/V Moire, Recall, 5 languages (Eng. Deu. Fra. Esp. Ita.)
39 S/N : 997863050110. TROUBLESHOOTINGCheck if power switch and computer power switchare in the on position.Check if power switch is in the on position.Check if the power cord is correctly connected.Adjust H&V Size or H&V Center to get the properimage.Keep the devices that may cause electrical  interfer-ence away from the monitor. See the FCC information at the front cover of themanual.Operate Degauss once.Adjust Contrast and Brightness.Operate Degauss once.Adjust Geometry Control (Pincushion, Trapezoid..).SymptomNo picture.POWER LED is notlit.Image is notcentered, too smallor too large.Picture bounces or a wave pattern ispresent in thepicture.Color looks blotchy.Picture is blurred.Edges of availablearea on the screenare not straight.Check