Wayne Dalton HHT-3720 Door Control Transmitter User Manual M Production Drawings 300623 3
Wayne Dalton Corporation Door Control Transmitter M Production Drawings 300623 3
Users Manual
Re: Certification for Wayne-Dalton Corp. 3BTM Transmitter Model: 3BTM FCC ID: KJ8HHT-3720 IC: 350A-3BTM3720 USER'S MANUAL INFORMATION (PRELIMINARY) The User's Manual is in preparation. The following material will be contained in the manual: FCC ID: KJ8HHT-3720 IC: 350A-3BTM3720 This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING: Changes or modifications not expressively approved by the party responsible for compliance could void the user's authority to operate the equipment. The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. 3 - Button Transmitter Model #3BTM WARNING! During programming the garage door may operate. Keep people and objects clear of the moving door to prevent door damage or possible personal injury. NOTE: For a new transmitter, you must change its security code before it can be programmed to the DoorMaster ™ or idrive™ operator. The Following steps describe the process to change a transmitter's security code. This process only works for transmitters with a "U" in their model number, such as "3BTM-0000 U" Changing Transmitter's Code 1. Press and hold the large button on the transmitter that you want to change. The RED LED will flash once and then turn off. 2. Continue to hold the button until the RED LED begins to flash (approx. 10 seconds). 3. When the RED LED flashes, immediately release the button and then immediately press and hold the button again. The RED LED will now come on steady. 4. Continue to hold the button until the RED LED begins to flash (approx. 5 seconds). 5. When the RED LED flashes, immediately release the button. The RED LED will blink three times. 6. The code for this button has now been changed to a new randomly generated code. 7. You must now program this transmitter to the garage door operator. See" Transmitter Programming". Transmitter Programming NOTE: Any of the three transmitter buttons can be programmed to activate the door. In multi-door installations, each button or a combination of two buttons pushed at the same time can be programmed to activate a separate door. To program the Transmitter: 1) Press program button on DoorMaster ™ light fixture or idrive™ powerhead; light fixture LED will light or powerhead will beep once. 2) Press and hold the desired transmitter button(s); LED will go off or powerhead will beep once. 3) Press and hold same transmitter button(s) again; door should operate. Transmitter is now programmed to operator. NOTE: idrive™ model only: The first transmitter ccommand after programming, will only open the door through a three inch up/down cycle. Normal door operation will then occur on all subsequent transmitter commands. DoorMaster™ idrive™ Large transmitter button program button LED Program button NOTE: The operator can be activated by up to six remote control devices (including wall station and keyless entry controls). If a seventh control is programmed, one of the programmed controls will be overwritten and will no longer activate the operator. To clear the programming of all remote control devices, press and hold the DoorMaster ™ light fixture program button or idrive ™ powerhead program button for approximately ten seconds. When the DoorMaster ™ light fixture LED goes out or idrive™ beeps three times, then all controls are erased. Door Activation Upon activation by either wall station or transmitter, door will move in following manner: 1. If closed, door will open. If open, door will close. 2. If closing, door will stop, reverse, and return to open position. Next activation will close. 3. If opening, door will stop. Next activation will close. 4. If an obstruction is encountered or an out of balance condition is detected while closing, door will reverse, return to open position, and DoorMaster ™ light fixture will flash 3 times or idrive will beep 3 times. Next activation will close door. 5. If an obstruction is encountered or an out of balance condition is detected while opening, door will stop, and DoorMaster ™ light fixture will flash 3 or 4 times or idrive ™ will beep 3 or 4 times . Next activation will close door. Never let children operate or play with door controls. Keep remote controls away from children. Fatal injury could result should a child become trapped between the door and the floor. P/N 300623 Always keep moving door in sight and away from people and objects until it is completely closed. To prevent serious injury or death, avoid standing in the open doorway or walking through the doorway while door is moving.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2003:01:29 14:59:39Z Modify Date : 2003:02:26 12:04:28-05:00 Page Count : 2 Creation Date : 2003:01:29 14:59:39Z Mod Date : 2003:02:26 12:04:28-05:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : jmurray Metadata Date : 2003:02:26 12:04:28-05:00 Creator : jmurray Title : M:\Production Drawings\300623\3 Has XFA : NoEXIF Metadata provided by EXIF.tools