Wellington Drive Technologies CLICK1 Bluetooth LE transmission adaptor, SCS Click User Manual Part 1 of 2
Wellington Drive Technologies Ltd Bluetooth LE transmission adaptor, SCS Click Users Manual Part 1 of 2
Contents
- 1. Users Manual_Part 1 of 2
- 2. Users Manual_Part 2 of 2
Users Manual_Part 1 of 2
TECHNICAL USER MANUAL CLICK © 2017 Wellington Drive Technologies Limited 21 Arrenway Drive, Rosedale, Auckland 0632, New Zealand PO Box 302-533, North Harbour, Auckland 0751, New Zealand Tel.: + 64 9 477 4500, Fax: + 64 9 479 5540, E-mail: info@wdtl.com Website: www.wdtl.com TABLE OF CONTENTS INTRODUCTION & WARNINGS TABLE OF CONTENTS TECHNICAL USER MANUAL 12 GRAPHICAL USER INTERFACES TABLE OF CONTENTS 21 UPGRADING FIRMWARE WARNINGS! 23 TECHNICAL SPECIFICATIONS INTRODUCTION 26 GLOSSARY AUTHENTICATION Process Overview IN-FIELD SET-UP 10 UPGRADING FIRMWARE EMS55 Set-up TECHNICAL SPECIFICATION GLOSSARY Installation Diagrams PD0012 V1.0 – 10 Oct 2017 APPENDICES PROCESS OVERVIEW DESCRIPTION & INSTALLATION Quick Read TABLE OF CONTENTS INTRODUCTION & WARNINGS WARNINGS! Quick Read DESCRIPTION & INSTALLATION Please read the following warnings to maintain the safe function and continued performance of your Wellington Drive Technologies Limited SCS™ CLICK: Installation; Installation of the SCS™ CLICK other than in accordance with the “Description & Install” section of this manual will invalidate the warranty. The SCS™ CLICK must only be installed and configured by trained and authorized staff. PROCESS OVERVIEW AUTHENTICATION No serviceable parts; There are no serviceable parts inside the SCS™ CLICK. Do not open the housing. Opening of the electronics housing, alterating or modifying the SCS™ CLICK will invalidate the warranty and can cause risk of electrocution. Consequential failures; Failure of connected components may cause damage to the SCS™ CLICK. Critical or vulnerable components should be protected independently against failure. SCS™ CLICK is not warranted against damage caused by or to other components. Fit for purpose; The SCS™ CLICK must only be used for the purpose and functions described in this manual. While Wellington Drive Technologies Limited may provide technical support on suitable applications and configuration of the SCS™ CLICK (where such a relationship may exist), no liability, responsibility or risk is accepted in determining if the SCS™ CLICK is fit for purpose for any particular application. no liability, responsibility or risk is accepted by Wellington Drive Technologies Limited for the correct operational function of any particular installation or configuration. IN-FIELD SET-UP UPGRADING FIRMWARE TECHNICAL SPECIFICATION GLOSSARY APPENDICES Continuous development; Wellington Drive Technologies Limited undertakes to continuously develop and improve products and services. The design and specification for the SCS™ CLICK is subject to change without warning. The contents of this manual are subject to change without warning. While every endeavour is made to ensure that all specifications and documents are current and complete, Wellington Drive Technologies Limited accepts no liability, responsibility or risk due to omissions or changes caused by continuous improvement and design changes. Users of this manual should verify that they have the current released version (published on the Wellington Drive Technologies website www.wdtl.com) before proceeding. Important Do’s and Dont’s: Do not drop the SCS™ CLICK. There are no serviceable parts inside the SCS™ CLICK. Do not open the housing. Warning! Risk of electrocution. The SCS™ CLICK must only be used for the purposes described in this manual. The design and specification of the SCS™ CLICK is subject to change without warning. PD0012 V1.0 – 10 Oct 2017 TABLE OF CONTENTS Quick Read Voltages: The SCS™ CLICK must only be connected to equipment which comply with the acceptable voltage ranges specified in the “Datasheet” and the “Technical Specification” section of this manual. Connection to supply voltages outside of these ranges can damage electrical circuits, leading to premature failure, and may cause the SCS™ CLICK to become unsafe and invalidates any warranty due to incorrect voltages. Do not drop the SCS™ CLICK. Do not connect the SCS™ CLICK to the incorrect supply voltage. DESCRIPTION & INSTALLATION Vibration and impact: The unit must be installed in such a way as to be protected from impact in operation. Exposure to impacts, either in operation, installation, transportation, or storage, may damage electronic circuits and housing components, leading to premature failure, and may cause the SCS™ CLICK to become unsafe. Any impact which causes visual damage to the housing will invalidate the waranty. PROCESS OVERVIEW AUTHENTICATION Temperature: The SCS™ CLICK must only be subjected to temperatures as specified in the “Datasheet” and the “Techinical specification” section of this manual. Exceeding these ranges either in operation, installation, transportation or storage, will invalidate the warranty and may damage electronic circuits and housing components, leading to premature failure. IN-FIELD SET-UP UPGRADING FIRMWARE Chemicals: The SCS™ CLICK must not be exposed to any solvents or chemicals, as this will invalidate the warranty and may damage the housing, leading to unsafe operation. The SCS Click must not be disposed off in municipal collections; it must be disposed off through an approved e-waste collection point. TECHNICAL SPECIFICATION GLOSSARY Correct disposal; The SCS™ CLICK is subject to EU Directive 2002/96/EC (WEEE) for e-waste. It may also be subject to other national legislation for the safe disposal of e-waste. The SCS™ CLICK must not be disposed off in municipal collections; it must be disposed off through an approved WEEE collection point. Alternatively, the SCS™ CLICK may be returned to an authorized Wellington Drive Technologies Limited distributor at the end of its working life. Penalties may be applicable for incorrect disposal, as specified by national legislation. The circuit board may contain hazardous substances which could affect health and the environment if disposed off incorrectly. The SCS™ CLICK complies with EU Directive 2002/95/EC (RoHS). PD0012 V1.0 – 10 Oct 2017 APPENDICES INTRODUCTION & WARNINGS Warnings - cont TABLE OF CONTENTS INTRODUCTION & WARNINGS INTRODUCTION Quick Read DESCRIPTION & INSTALLATION The SCS™ CLICK by Wellington is an Bluetooth LE transmission adaptor designed for providing radio connectivity to existing refrigeration controllers in the market. It adds functionalities such as telemetry connectivy, asset tracking, and proximity based marketing capabilities to existing coolers. The interface system permits different groups of users to have different levels of control, based upon their levels of expertise and their actual control needs. PROCESS OVERVIEW A unique feature is a mobile app that gives authorized Service Technicians full wireless access to data logging and diagnostic control. Highly flexible and configurable Mobile app with intuitive touch screen interface Wireless data logging and diagnostic control Compact size AUTHENTICATION IN-FIELD SET-UP UPGRADING FIRMWARE TECHNICAL SPECIFICATION GLOSSARY APPENDICES PD0012 V1.0 – 10 Oct 2017 TABLE OF CONTENTS Installation INTRODUCTION & WARNINGS Installation Diagrams INSTALLATION PROCEDURE: PROCESS OVERVIEW DESCRIPTION & INSTALLATION STEP 1 Remove the two screws holding the RJ45 cover in place with PZ1 screwdriver and remove cover AUTHENTICATION STEP 2 Push SCS Click fully into the RJ45 socket. IN-FIELD SET-UP Ensure it makes a Click sound, and the retaining feature is clicked into place. TECHNICAL SPECIFICATION UPGRADING FIRMWARE STEP 3 Ensure that the SCS Click is flashing green every few seconds. This means it is installed correctly and powered up. PD0012 V1.0 – 10 Oct 2017 APPENDICES GLOSSARY STEP 4 Replace the cover and two screws. TABLE OF CONTENTS Installation INTRODUCTION & WARNINGS EMS55 Set-up EMS55 SETUP PROCEDURE: STEP 1 DESCRIPTION & INSTALLATION Press the top left button (“a“), Will then be ready to accept the password. PROCESS OVERVIEW STEP 2 AUTHENTICATION Enter the password by pressing the buttons in the following order. Top Left (“a“) - 3 times Top right (“b“) - 2 times IN-FIELD SET-UP Bottom right (“c“) - 1 time Bottom left (“d“) - 4 times UPGRADING FIRMWARE STEP 3 The display will now show P5. TECHNICAL SPECIFICATION GLOSSARY STEP 4 Press the Bottom right (“c“) button 5 times until “ddP” is displayed. It will the alternate between displaying “ddP’ and “00” APPENDICES PD0012 V1.0 – 10 Oct 2017 TABLE OF CONTENTS Installation INTRODUCTION & WARNINGS EMS55 Set-up EMS55 SETUP PROCEDURE: PROCESS OVERVIEW DESCRIPTION & INSTALLATION STEP 5 Press the Top Left (“a“) button once. The display will now be alternating between displaying “ddP’ and “00”. STEP 6 AUTHENTICATION Hold the Top right (“b“) button until “01” is displayed. IN-FIELD SET-UP Display will then alternate between “ddP” and “01”. PD0012 V1.0 – 10 Oct 2017 APPENDICES GLOSSARY TECHNICAL SPECIFICATION UPGRADING FIRMWARE STEP 7 Wait for 20-30 secs for the Elstat to timeout. It will then re-boot and return to normal operation. TABLE OF CONTENTS Installation INTRODUCTION & WARNINGS Process Overview Process steps involving the SCS Connect Field mobile app are described step by step below. Before connecting to the cooler with the app, take photos of DESCRIPTION & INSTALLATION • The outlet (from the outside). • The cooler. • The area of the outlet where the cooler is located, showing enough of the surroundings to understand the cooler’s in-store position. ARRIVE AT STORE PROCESS OVERVIEW Take Store Photo AUTHENTICATION Install Cabinet Install Cabinet Take Cooler Photo IN-FIELD SET-UP Connect to Controller Set ASSET NUMBER It is VITAL that the asset number is set. If this is not set, no reporting or asset tracking of the cooler can be made. UPGRADING FIRMWARE Set SERIAL NUMBER Set Installation Address TECHNICAL SPECIFICATION Set Store Photo Set Cooler Photo GLOSSARY COMPLETE APPENDICES 10 PD0012 V1.0 – 10 Oct 2017 TABLE OF CONTENTS Quick Read The SCS Connect Field mobile app requires four attributes to be entered during the entire installation process: Serial No. DESCRIPTION & INSTALLATION The order in which data is entered into the SCS CLICK, and at which process step may differ from manufacturer to manufacturer and owner to owner depending on existing manufacturing processes. Model Asset No. Installation Address Additional data Photo and Notes PROCESS OVERVIEW Cabinet installation in the field. Information is entered through the use of a mobile phone application (See page 15) Attributes can be set Model Used by the automated fault detection AUTHENTICATION Serial No. Used for recording purposes Asset No. Used for cooler identification in asset tracking Installation Address Used by the asset tracking IN-FIELD SET-UP Addition attributes which can be entered into the SCS Connect mobile app in the field are; Additional data GLOSSARY TECHNICAL SPECIFICATION UPGRADING FIRMWARE Photo and Notes PD0012 V1.0 – 10 Oct 2017 11 APPENDICES During two of the process steps, data is required to be entered into the controller. INTRODUCTION & WARNINGS Process Overview TABLE OF CONTENTS INTRODUCTION & WARNINGS GRAPHICAL USER INTERFACES Quick Read DESCRIPTION & INSTALLATION The Wellington SCS Connect App provides a wireless connection to the SCS CLICK from mobile devices fitted with Bluetooth® LE. This gives users and technicians an unprecedented level of visibility and control. The following guide provides an overview of the app and its capabilities. PROCESS OVERVIEW Note: Screen shots shown are indicative only. Different devices have different screen ratios, sizes and resolutions. The actual image seen on your device may vary from the screen shots shown in this guide. Holding your device in portrait or landscape mode may have an effect on appearance and may change how the various windows and graphics are displayed and arranged on your screen. Bluetooth® SMART compliant. Wireless diagnostics and control. Customized app branding available on special request. Secure, only authorized connections permitted. AUTHENTICATION User Interfaces IN-FIELD SET-UP UPGRADING FIRMWARE TECHNICAL SPECIFICATION GLOSSARY APPENDICES 12 PD0012 V1.0 – 10 Oct 2017 TABLE OF CONTENTS In-Field Set-up Step 2 PROCESS OVERVIEW DESCRIPTION & INSTALLATION Step 1 INTRODUCTION & WARNINGS Installation and Authentication When you first run “Connect Field”, you will be requested to enter an activation code. Contact your User Manager or Wellington to receive your activation code (You must be connected to the internet at the time of activation). AUTHENTICATION Download and install the Connect Field app from Google Play (Search for “scs wellington” to find it) Step 3 IN-FIELD SET-UP Note: Your activation code is unique to you, and should NEVER be shared with anyone else, as it determines your personal access level for the app. The same code will give you access to all SCS apps you are authorised to use. Step 4 TECHNICAL SPECIFICATION UPGRADING FIRMWARE Your 9-digit touch panel code PD0012 V1.0 – 10 Oct 2017 GLOSSARY You can see which databases you are activated against from the “Settings” screen. You can be activated to more than one database at the same time. Simply select “ACTIVATE ANOTHER DATABASE”, and enter the new databases unique activation code, as in Step 2. 13 APPENDICES Once activation is complete, you must define a 4-digit PIN code. This can be any code unique to you. Each time you start the app, you will be required to enter this same PIN code. This is to prevent other people accessing the app from unlocked phones. TABLE OF CONTENTS MOBILE GUI - cont INTRODUCTION & WARNINGS In-Field Set-up DESCRIPTION & INSTALLATION Select a device to connect to from the list of visable devices. PROCESS OVERVIEW Note: This list is filtered by your activation permissions, so devices you are not authorised to connect to will not be displayed. Select “Connect” to connect to the Note: cooler AUTHENTICATION The signal strength is the number in brackets on the right of the cooler ID. If signal strength is lower (more –ve) than -80, connection may be unreliable: move closer to the cooler. If multiple cooler IDs are visible, the strongest (least –ve) signal is likely to be the one closest to you and make sure Bluetooth is turned on. Home Screen IN-FIELD SET-UP The Home Screen shows a graphic representation of the current state of the refrigeration unit being controlled. Graph and Output Control Event History Home Screen UPGRADING FIRMWARE Menu Button Status Bar TECHNICAL SPECIFICATION Return-air Temperature GLOSSARY Cooler Temperature Home Screen (Fridge Status) APPENDICES 14 Main Menu PD0012 V1.0 – 10 Oct 2017 TABLE OF CONTENTS MOBILE GUI - cont PROCESS OVERVIEW DESCRIPTION & INSTALLATION INTRODUCTION & WARNINGS In-Field Setup TECHNICAL SPECIFICATION Choose EDIT to add the Cooler Asset Number. Push OK GLOSSARY A pop up will show with “Manufacturer needs to be set” Dialogue box. PD0012 V1.0 – 10 Oct 2017 15 APPENDICES Select the dropdown menu and select the cooler manufacturer. UPGRADING FIRMWARE IN-FIELD SET-UP AUTHENTICATION Select “SCS Setup” from the Main menu
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 15 Producer : PDF Editor 2.2 - Foxit Software Author : Stephan Huck Create Date : 2018:03:16 13:23:46 Modify Date : 2018:03:16 13:23:46EXIF Metadata provided by EXIF.tools