Wellington Drive Technologies CLICK1 Bluetooth LE transmission adaptor, SCS Click User Manual Part 1 of 2

Wellington Drive Technologies Ltd Bluetooth LE transmission adaptor, SCS Click Users Manual Part 1 of 2

Contents

Users Manual_Part 1 of 2

Download: Wellington Drive Technologies CLICK1 Bluetooth LE transmission adaptor, SCS Click User Manual Part 1 of 2
Mirror Download [FCC.gov]Wellington Drive Technologies CLICK1 Bluetooth LE transmission adaptor, SCS Click User Manual Part 1 of 2
Document ID3783347
Application IDlztepXQSCCeG+6NImmz8xg==
Document DescriptionUsers Manual_Part 1 of 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize98.76kB (1234541 bits)
Date Submitted2018-03-16 00:00:00
Date Available2018-06-16 00:00:00
Creation Date2018-03-16 13:23:46
Producing SoftwarePDF Editor 2.2 - Foxit Software
Document Lastmod2018-03-16 13:23:46
Document TitleUsers Manual_Part 1 of 2
Document Author: Stephan Huck

TECHNICAL USER MANUAL
CLICK
© 2017 Wellington Drive Technologies Limited
21 Arrenway Drive, Rosedale, Auckland 0632, New Zealand
PO Box 302-533, North Harbour, Auckland 0751, New Zealand
Tel.:    + 64 9 477 4500, Fax:   + 64 9 479 5540,
E-mail: info@wdtl.com Website: www.wdtl.com
TABLE OF
CONTENTS
INTRODUCTION
& WARNINGS
TABLE OF CONTENTS
TECHNICAL USER MANUAL
12
GRAPHICAL USER INTERFACES
TABLE OF CONTENTS
21
UPGRADING FIRMWARE
WARNINGS!
23
TECHNICAL SPECIFICATIONS
INTRODUCTION
26
GLOSSARY
AUTHENTICATION
Process Overview
IN-FIELD SET-UP
10		
UPGRADING
FIRMWARE
EMS55 Set-up
TECHNICAL
SPECIFICATION
GLOSSARY
Installation Diagrams
PD0012 V1.0 – 10 Oct 2017
APPENDICES
PROCESS
OVERVIEW
DESCRIPTION
& INSTALLATION
Quick Read
TABLE OF
CONTENTS
INTRODUCTION
& WARNINGS
WARNINGS!
Quick Read
DESCRIPTION
& INSTALLATION
Please read the following warnings to maintain the safe function
and continued performance of your Wellington Drive Technologies
Limited SCS™ CLICK:

Installation;
Installation of the SCS™ CLICK other than in accordance with
the “Description & Install” section of this manual will invalidate
the warranty. The SCS™ CLICK must only be installed and
configured by trained and authorized staff.
PROCESS
OVERVIEW
AUTHENTICATION
No serviceable parts;
There are no serviceable parts inside the SCS™ CLICK. Do
not open the housing.  Opening of the electronics housing,
alterating or modifying the SCS™ CLICK will invalidate the
warranty and can cause risk of electrocution.

Consequential failures;
Failure of connected components may cause damage to the
SCS™ CLICK. Critical or vulnerable components should be
protected independently against failure. SCS™ CLICK is not
warranted against damage caused by or to other components.

Fit for purpose;
The SCS™ CLICK must only be used for the purpose and
functions described in this manual.  While Wellington Drive
Technologies Limited may provide technical support on suitable
applications and configuration of the SCS™ CLICK (where such
a relationship may exist), no liability, responsibility or risk is
accepted in determining if the SCS™ CLICK is fit for purpose
for any particular application. no liability, responsibility or risk
is accepted by Wellington Drive Technologies Limited for the
correct operational function of any particular installation or
configuration.
IN-FIELD SET-UP

UPGRADING
FIRMWARE

TECHNICAL
SPECIFICATION
GLOSSARY
APPENDICES
Continuous development;
Wellington Drive Technologies Limited undertakes to
continuously develop and improve products and services.  The
design and specification for the SCS™ CLICK is subject to change
without warning.  The contents of this manual are subject to
change without warning.  While every endeavour is made to
ensure that all specifications and documents are current and
complete, Wellington Drive Technologies Limited accepts no
liability, responsibility or risk due to omissions or changes
caused by continuous improvement and design changes.  Users
of this manual should verify that they have the current released
version (published on the Wellington Drive Technologies
website www.wdtl.com) before proceeding.
Important Do’s and Dont’s:

Do not drop the SCS™
CLICK.

There are no serviceable
parts inside the SCS™
CLICK. Do not open the
housing. Warning! Risk of
electrocution.

The SCS™ CLICK must only
be used for the purposes
described in this manual.

The design and
specification of the SCS™
CLICK is subject to change
without warning.
PD0012 V1.0 – 10 Oct 2017
TABLE OF
CONTENTS
Quick Read

Voltages:
The SCS™ CLICK must only be connected to equipment
which comply with the acceptable voltage ranges specified
in the “Datasheet” and the “Technical Specification” section
of this manual. Connection to supply voltages outside of
these ranges can damage electrical circuits, leading to
premature failure, and may cause the SCS™ CLICK to become
unsafe and invalidates any warranty due to incorrect
voltages.

Do not drop the SCS™
CLICK.

Do not connect the SCS™
CLICK to the incorrect
supply voltage.
DESCRIPTION
& INSTALLATION
Vibration and impact:
The unit must be installed in such a way as to be protected
from impact in operation. Exposure to impacts, either in
operation, installation, transportation, or storage, may
damage electronic circuits and housing components, leading
to premature failure, and may cause the SCS™ CLICK to
become unsafe. Any impact which causes visual damage to
the housing will invalidate the waranty.
PROCESS
OVERVIEW

AUTHENTICATION
Temperature:
The SCS™ CLICK must only be subjected to temperatures
as specified in the “Datasheet” and the “Techinical
specification” section of this manual. Exceeding these ranges
either in operation, installation, transportation or storage,
will invalidate the warranty and may damage electronic
circuits and housing components, leading to premature
failure.
IN-FIELD SET-UP

UPGRADING
FIRMWARE
Chemicals:
The SCS™ CLICK must not be exposed to any solvents or
chemicals, as this will invalidate the warranty and may
damage the housing, leading to unsafe operation.
The SCS Click must not be
disposed off in municipal
collections; it must be
disposed off through an
approved e-waste collection
point.
TECHNICAL
SPECIFICATION


GLOSSARY
Correct disposal;
The SCS™ CLICK is subject to EU Directive 2002/96/EC
(WEEE) for e-waste.  It may also be subject to other national
legislation for the safe disposal of e-waste.  The SCS™
CLICK must not be disposed off in municipal collections; it
must be disposed off through an approved WEEE collection
point.  Alternatively, the SCS™ CLICK may be returned to an
authorized Wellington Drive Technologies Limited distributor
at the end of its working life.  Penalties may be applicable
for incorrect disposal, as specified by national legislation.  
The circuit board may contain hazardous substances which
could affect health and the environment if disposed off
incorrectly. The SCS™ CLICK complies with EU Directive
2002/95/EC (RoHS).
PD0012 V1.0 – 10 Oct 2017
APPENDICES

INTRODUCTION
& WARNINGS
Warnings - cont
TABLE OF
CONTENTS
INTRODUCTION
& WARNINGS
INTRODUCTION
Quick Read
DESCRIPTION
& INSTALLATION
The SCS™ CLICK by Wellington is an Bluetooth LE transmission
adaptor designed for providing radio connectivity to existing
refrigeration controllers in the market. It adds functionalities
such as telemetry connectivy, asset tracking, and proximity based
marketing capabilities to existing coolers.
The interface system permits different groups of users to have
different levels of control, based upon their levels of expertise and
their actual control needs.
PROCESS
OVERVIEW
A unique feature is a mobile app that gives authorized Service
Technicians full wireless access to data logging and diagnostic
control.
††
Highly flexible and 		
configurable
††
Mobile app with intuitive
touch screen interface
††
Wireless data logging and
diagnostic control
††
Compact size
AUTHENTICATION
IN-FIELD SET-UP
UPGRADING
FIRMWARE
TECHNICAL
SPECIFICATION
GLOSSARY
APPENDICES
PD0012 V1.0 – 10 Oct 2017
TABLE OF
CONTENTS
Installation
INTRODUCTION
& WARNINGS
Installation Diagrams
INSTALLATION PROCEDURE:
PROCESS
OVERVIEW
DESCRIPTION
& INSTALLATION
STEP 1
Remove the two screws
holding the RJ45 cover in
place with PZ1 screwdriver
and remove cover
AUTHENTICATION
STEP 2
Push SCS Click fully into the
RJ45 socket.
IN-FIELD SET-UP
Ensure it makes a Click
sound, and the retaining
feature is clicked into place.
TECHNICAL
SPECIFICATION
UPGRADING
FIRMWARE
STEP 3
Ensure that the SCS Click
is flashing green every few
seconds. This means it
is installed correctly and
powered up.
PD0012 V1.0 – 10 Oct 2017
APPENDICES
GLOSSARY
STEP 4
Replace the cover and two
screws.
TABLE OF
CONTENTS
Installation
INTRODUCTION
& WARNINGS
EMS55 Set-up
EMS55 SETUP PROCEDURE:
STEP 1
DESCRIPTION
& INSTALLATION
Press the top left button
(“a“), Will then be ready to
accept the password.
PROCESS
OVERVIEW
STEP 2
AUTHENTICATION
Enter the password by
pressing the buttons in the
following order.
Top Left (“a“) - 3 times
Top right (“b“) - 2 times
IN-FIELD SET-UP
Bottom right (“c“) - 1 time
Bottom left (“d“) - 4 times
UPGRADING
FIRMWARE
STEP 3
The display will now show
P5.
TECHNICAL
SPECIFICATION
GLOSSARY
STEP 4
Press the Bottom right (“c“)
button 5 times until “ddP”
is displayed. It will the
alternate between displaying
“ddP’ and “00”
APPENDICES
PD0012 V1.0 – 10 Oct 2017
TABLE OF
CONTENTS
Installation
INTRODUCTION
& WARNINGS
EMS55 Set-up
EMS55 SETUP PROCEDURE:
PROCESS
OVERVIEW
DESCRIPTION
& INSTALLATION
STEP 5
Press the Top Left (“a“)  
button once.  The display will
now be alternating between
displaying “ddP’ and “00”.
STEP 6
AUTHENTICATION
Hold the Top right (“b“)
button until “01” is displayed.
IN-FIELD SET-UP
Display will then alternate
between “ddP” and “01”.
PD0012 V1.0 – 10 Oct 2017
APPENDICES
GLOSSARY
TECHNICAL
SPECIFICATION
UPGRADING
FIRMWARE
STEP 7
Wait for 20-30 secs for the
Elstat to timeout.  It will then
re-boot and return to normal
operation.
TABLE OF
CONTENTS
Installation
INTRODUCTION
& WARNINGS
Process Overview
Process steps involving the SCS Connect Field mobile app are described step by step below.
Before connecting to the cooler with the app, take photos of
DESCRIPTION
& INSTALLATION
•
The outlet (from the outside).
•
The cooler.
•
The area of the outlet where the cooler is located, showing enough of the surroundings to
understand the cooler’s in-store position.
ARRIVE AT STORE
PROCESS
OVERVIEW
Take Store Photo
AUTHENTICATION
Install Cabinet
Install Cabinet
Take Cooler Photo
IN-FIELD SET-UP
Connect to Controller
Set ASSET NUMBER
It is VITAL that the asset number is set. If this
is not set, no reporting or asset tracking of
the cooler can be made.
UPGRADING
FIRMWARE
Set SERIAL NUMBER
Set Installation Address
TECHNICAL
SPECIFICATION
Set Store Photo
Set Cooler Photo
GLOSSARY
COMPLETE
APPENDICES
10
PD0012 V1.0 – 10 Oct 2017
TABLE OF
CONTENTS
Quick Read
The SCS Connect Field mobile app requires four attributes to be
entered during the entire installation process:
††Serial No.
DESCRIPTION
& INSTALLATION
The order in which data is entered into the SCS CLICK, and
at which process step may differ from manufacturer to
manufacturer and owner to owner depending on existing
manufacturing processes.
††Model
††Asset No.
††Installation Address
††Additional data
††Photo and Notes
PROCESS
OVERVIEW
†† Cabinet installation in the field.
Information is entered through the use of a mobile phone
application (See page 15)
††
Attributes can be set
†† Model
Used by the automated fault detection
AUTHENTICATION
†† Serial No.
Used for recording purposes
†† Asset No.
Used for cooler identification in asset tracking
†† Installation Address
Used by the asset tracking
IN-FIELD SET-UP
Addition attributes which can be entered into the SCS Connect
mobile app in the field are;
†† Additional data
GLOSSARY
TECHNICAL
SPECIFICATION
UPGRADING
FIRMWARE
†† Photo and Notes
PD0012 V1.0 – 10 Oct 2017
11
APPENDICES
During two of the process steps, data is required to be entered
into the controller.
INTRODUCTION
& WARNINGS
Process Overview
TABLE OF
CONTENTS
INTRODUCTION
& WARNINGS
GRAPHICAL USER INTERFACES
Quick Read
DESCRIPTION
& INSTALLATION
The Wellington SCS Connect App provides a wireless connection
to the SCS CLICK from mobile devices fitted with Bluetooth®
LE.  This gives users and technicians an unprecedented level of
visibility and control.  The following guide provides an overview
of the app and its capabilities.
PROCESS
OVERVIEW
Note: Screen shots shown are indicative only.   Different
devices have different screen ratios, sizes and resolutions. The
actual image seen on your device may vary from the screen
shots shown in this guide.  Holding your device in portrait or
landscape mode may have an effect on appearance and may
change how the various windows and graphics are displayed
and arranged on your screen.
††
Bluetooth® SMART compliant.
††
Wireless diagnostics and
control.
††
Customized app branding
available on special request.
††
Secure, only authorized
connections permitted.
AUTHENTICATION
User Interfaces
IN-FIELD SET-UP
UPGRADING
FIRMWARE
TECHNICAL
SPECIFICATION
GLOSSARY
APPENDICES
12
PD0012 V1.0 – 10 Oct 2017
TABLE OF
CONTENTS
In-Field Set-up
Step 2
PROCESS
OVERVIEW
DESCRIPTION
& INSTALLATION
Step 1
INTRODUCTION
& WARNINGS
Installation and Authentication
When you first run “Connect Field”, you will
be requested to enter an activation code.  
Contact your User Manager or Wellington
to receive your activation code (You must
be connected to the internet at the time of
activation).
AUTHENTICATION
Download and install the Connect Field
app from Google Play (Search for “scs
wellington” to find it)
Step 3
IN-FIELD SET-UP
Note:
Your activation code is unique to you, and should NEVER be shared with anyone else, as it
determines your personal access level for the app.  The same code will give you access to all
SCS apps you are authorised to use.
Step 4
TECHNICAL
SPECIFICATION
UPGRADING
FIRMWARE
Your 9-digit
touch panel
code
PD0012 V1.0 – 10 Oct 2017
GLOSSARY
You can see which databases you are
activated against from the “Settings” screen.  
You can be activated to more than one
database at the same time.  Simply select
“ACTIVATE ANOTHER DATABASE”, and enter
the new databases unique activation code,
as in Step 2.
13
APPENDICES
Once activation is complete, you must
define a 4-digit PIN code.  This can be any
code unique to you.  Each time you start
the app, you will be required to enter this
same PIN code. This is to prevent other
people accessing the app from unlocked
phones.
TABLE OF
CONTENTS
MOBILE GUI - cont
INTRODUCTION
& WARNINGS
In-Field Set-up
DESCRIPTION
& INSTALLATION
Select a device to
connect to from the list
of visable devices.
PROCESS
OVERVIEW
Note: This list is filtered by your activation
permissions, so devices you are not
authorised to connect to will not be
displayed.
Select “Connect”
to connect to the
Note:
cooler
AUTHENTICATION
The signal strength is the number in brackets on the right of the cooler ID. If signal strength
is lower (more –ve) than -80, connection may be unreliable: move closer to the cooler. If
multiple cooler IDs are visible, the strongest (least –ve) signal is likely to be the one closest to
you and make sure Bluetooth is turned on.
Home Screen
IN-FIELD SET-UP
The Home Screen shows a graphic representation of the current state of the refrigeration unit
being controlled.
Graph and
Output Control
Event History
Home Screen
UPGRADING
FIRMWARE
Menu Button
Status Bar
TECHNICAL
SPECIFICATION
Return-air
Temperature
GLOSSARY
Cooler
Temperature
Home Screen
(Fridge Status)
APPENDICES
14
Main Menu
PD0012 V1.0 – 10 Oct 2017
TABLE OF
CONTENTS
MOBILE GUI - cont
PROCESS
OVERVIEW
DESCRIPTION
& INSTALLATION
INTRODUCTION
& WARNINGS
In-Field Setup
TECHNICAL
SPECIFICATION
Choose EDIT to
add the Cooler
Asset Number.
Push OK
GLOSSARY
A pop up will show with
“Manufacturer needs to be
set” Dialogue box.
PD0012 V1.0 – 10 Oct 2017
15
APPENDICES
Select the dropdown
menu and select the
cooler manufacturer.
UPGRADING
FIRMWARE
IN-FIELD SET-UP
AUTHENTICATION
Select “SCS Setup”
from the Main menu

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 15
Producer                        : PDF Editor 2.2 - Foxit Software
Author                          : Stephan Huck
Create Date                     : 2018:03:16 13:23:46
Modify Date                     : 2018:03:16 13:23:46
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AHCE-CLICK1

Navigation menu