Westell CSIDRACELAAWS AWS Repeater User Manual 960 1042 006 Manual John r006 indd
Westell, Inc. AWS Repeater 960 1042 006 Manual John r006 indd
Westell >
User Manual
CSI-DRACELA-PR-AW CS12-560-419 WARNING: This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES AND QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. The Installation height of the antenna for AWS band 1700/2100 MHz operations is limited to 10 meters above ground for compliance with FCC Regulation Section 27.50 Important Safety Information Antennas used for the purpose of radiating signals indoors are limited to a maximum gain of 3 dBi. The outdoor antenna used for the purpose of communicating to the wireless infrastructure is limited to -2 dBi, or any combination of gain and loss that equates to -2 dBi at output. Each antenna must be positioned to observe minimum separation requirements from all users and bystanders. The following guidelines should be used when considering separation distances. INDOOR antennas must be placed such that, under normal conditions, personnel cannot come within 20 cm (~8.0 in.) from any inside antenna. Adhering to this minimum separation will ensure that the employee or bystander cannot exceed RF exposures beyond the maximum permissible limit as defined by section 1.1310 i.e. limits for General Population/Uncontrolled Exposure. OUTDOOR antenna must be positioned such that, under normal conditions, personnel cannot approach closer than 120 cm. (~4 ft.). A non- directional antenna having a maximum gain of -2 dBi is used, precautions should be taken to prevent personnel from routinely passing closer than specified. Radio and Television Interference NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes and Modifications not expressly approved by Cellular Specialties, Inc. can void your authority to operate this equipment under Federal Communications Commission’s rules. Cellular Specialties, Inc. grants to the purchaser a fully paid license, at no additional charge, to copy or otherwise reproduce all or portions of the product documentation. Such reproduction shall be for the purchasers use only. Table of Contents Section 1........................................................................................................................... 5 Hardware Configuration..................................................................................................... 5 Module Side View............................................................................................................... 5 Module Face Plate View..................................................................................................... 5 Module Top View................................................................................................................ 5 Installation.......................................................................................................................... 6 Physical Installation Into The Train.................................................................................... 6 Module Interconnection Diagram....................................................................................... 7 RF and Power Cabling....................................................................................................... 7 Section 2........................................................................................................................................ 7 Face Plate Dimensions...................................................................................................... 8 Top View Dimensions......................................................................................................... 9 Power Up............................................................................................................................ 10 Normal Operation............................................................................................................... 10 System Status.................................................................................................................... 10 Alarms................................................................................................................................ 10 Alarm Notification Message............................................................................................... 10 Hardware Operations......................................................................................................... 11 Test Point Locations and Values........................................................................................ 11 Indicator Lights................................................................................................................... 11 Troubleshooting.................................................................................................................. 11 Section 3.........................................................................................................................................11 Warranty and Repair Procedures....................................................................................... 13 Local Communication Interface Ports................................................................................. 16 EIA232 Pin Specifications...................................................................................................16 General Operation Overview.............................................................................................. 16 Section 4........................................................................................................................... 16 Ethernet.............................................................................................................................. 17 Monitoring & Alarms........................................................................................................... 17 Text Menu Interface............................................................................................................ 17 Local Access....................................................................................................................... 17 Figure 1...............................................................................................................................17 Figure 2...............................................................................................................................17 Login................................................................................................................................... 19 Main Menu.......................................................................................................................... 19 Set Parameters Menu......................................................................................................... 19 Telnet Session TCP/IP........................................................................................................ 20 Maintenance Mode............................................................................................................. 39 Terms used in this manual.................................................................................................. 40 -4- Section 1 Hardware Configuration Module Side View Warning: The protective cover for the serial port must be securely fastened when the port is not in use to prevent compromise of enclosure integrity. Serial Port Module Top View Status LED FCC Label Modem PCS Server COM Server Ant Cell Server PCS Donor U7C Server Cell Donor Module Face Plate View -5- DC Out Donor Ant U7C Donor Power LED DC In Installation Section 1 1. Unpack the box containing the CSI 1K repeater system module. 2. After unpacking the components, verify all parts and cables are present. If any parts are discovered to be missing contact Cellular Specialties, Inc. at 1-877-844-4274 to arrange for replacements to be sent. Note: all supplied cables are fire resistant, low halogen. 3. Install the repeater in the new rack attached at bottom of the existing system frame and secure in place with 4 - #10-32 screws . Physical Installation Into The Train -6 - Installation Section 2 1. Remove the male input connector of the CBL/A 72VDC PIGTAIL, 820-2164-001, from the train’s 72VDC power supply cable and connect it to the female DC OUT connector on the 1K module. The other connectors on this cable assembly will remain installed in their current locations. Install the connector of the 72VDC power supply cable from the train into the port labeled DC IN on the 1K unit. 2. Remove the train’s donor antenna feed cable from the COMMON port on the 1B module and connect it to the port labeled DONOR ANTENNA on the 1K module. 3. Remove the train’s radiax cable feed from the second COMMON port on the 1B module and connect it to the port labeled SERVER ANTENNA port on the 1K module. 4. Remove the 820-2064-001 cable that connects the right hand coupler port labeled LOW on the 1H module to the DONOR ANT port on the 1J module. 5. Install the supplied Rubber Duck antenna in the 1K module, MODEM port. 6. Remove the 820-2064-001 cable that connects the right hand coupler port labeled HIGH on the 1B module to the DONOR ANT port on the 1C module. 7. Remove the CS54-3059-12 cable that connects the right hand coupler port labeled HIGH on the 1H module to the DONOR ANT port on the 1F module. 8. Remove the 820-2124-001 cable that connects the left hand coupler port labeled LOW on the 1H module to the DAS port on the 1G module. 9. Remove the 820-2124-001 cable that connects the left hand coupler port labeled HIGH on the 1B module to the DAS port on the 1A module. 10. Remove the CS54-3059-12 cable that connects the left hand coupler port labeled HIGH on the 1H module to the DAS port on the 1D module. 11. Remove the CS54-3154-12 cable that connects the left hand coupler port labeled COMMON on the 1H module to the left hand coupler port labeled LOW on the 1B module. 12. Remove the CS54-3154-12 cable that connects the right hand coupler port labeled COMMON on the 1H module to the right hand coupler port labeled LOW on the 1B module. 13. Connect one supplied 820-2124-036 cable from the DAS port on the 1G module to the U7C SERVER port on the 1K module. 14. Connect one supplied 820-2124-036 cable from the DONOR ANT port on the 1J module to the U7C DONOR port on the 1K module. 15. Connect one supplied 820-2194-001 cable from the port 5 on the 1E module to the COM port on the 1K module. 16. Connect one supplied 820-2124-036 cable from the DAS port on the 1D module to the CELL SERVER port on the 1K module. 17. Connect one supplied 820-2124-036 cable from the DAS port on the 1A module to the PCS SERVER port on the 1K module. 18. Connect one supplied 820-2124-036 cable from the DONOR ANT port on the 1F module to the CELL DONOR port on the 1K module. 19. Connect one supplied 820-2124-036 cable from the DONOR ANT port on the 1C module to the PCS DONOR port on the 1K module. RF and Power Cabling - 7- Section 2 Step 13 Step 14 Step 15 Step 5 Step 16 1J 1H 1G Step 17 Step 18 Step 19 1D 1E 1F 1K 1C Step 3 To Radiax Step 2 To Donor 1B 1A Step 1 72 VDC Module Interconnection Diagram -8- Section 2 1.29 18.06 33.58 34.58 3.41 Face Plate Dimensions 9.28 Top View Dimensions -9- Section 2 Installation Power Up To power up the CSI repeater simply connect the 72 VDC power cable from the train to the DC IN port on the Power Module. When powered up, the repeater will begin in the Operational Mode, using the “Band Switching Algorithm”. The repeater will not key until boot up is complete, a GPS location fix is obtained and the unit is within an ” Area Definition”. Normal Operation After boot up and a GPS position fix is obtain the repeater will begin operation based on the Area Definitions, “Channel Power Measurement and Keying Decision” and “Low Isolation Detection and Protection” algorithms. The operational software will continuously monitor the repeater’s environment and make the necessary adjustments to keep the product operating within specifications and FCC Type Certification. System Status The Software provides real time status data reporting the state of the repeater. This status contains: Wide Area network: GPS Location Data: System Info: Remote Enabled Run State Location Modem Type Latitude Model IP Address Longitude Board Type PCS Filter ID Carrier SNMP Configuration: Location SW Version Enabled BTA Serial Number Read-only User Satellite Count Item Number Read-write User No Box Count Date Built Read-only User Searching Count Watchdog Timer Read-only Community CPLD Version Read-write Community Traps/Informs Software Build Information: Heartbeat Builder Modem Status: URL RF Alarms: Connected Revision Over Range Compile Date Oscillation Local Area network: VSWR Hostname Out if Band Overdrive Boot Protocol Low Signal IP Address No Signal MAC Address Scan Receiver: Run State Dekey Limit Filter ID Channels Channel-1 Channel-2 Channel-3 Channel-4 Channel-5 System Alarms: Synthesizer Voltage Temperature Software Hardware Alarms The Operating Software will monitor the repeater for conditions that are out of normal operation, triggering an alarm event. The Operating software in conjunction with the Communications Subsystem when so configured will send alarm messages via E-mail or SMS texting to a User Provisioned account. Each Alarm has these User Provisioned Capabilities.: · · · · Disable the System: The Operating software can disable the System (prohibit Keying) until the alarm condition is cleared if provisioned Alarm Filter Conditions: A Filter Condition (such as X number of occurrences per hour) to the alarm to prevent false or unuseful notifications if provisioned. Send an Alarm Message: The Operating Software can send a notification via message E-mail or SMS through the Communications Subsystem if provisioned. Alarm Clear Message: The Operating Software can send an alarm clear message when an alarm condition clears if provisioned. Alarm Notification Message The alarm messages consists of the Systems Identification Tag, a summary of the current alarms, and a short English message describing the alarm condition(s). Below is a list of the alarms that will trigger an alarm message to be sent.: Downlink Over Range Uplink Over Range Synthesizer Error DAC Error DC Current High DC Current Low Downlink High VSWR Downlink Low VSWR Downlink Filter Load Downlink Over Current Downlink Under Current Downlink High Temperature Downlink Low Temperature Uplink High VSWR Uplink Low VSWR Uplink Filter Load Uplink Over Current Uplink Under Current Oscillation Uplink High Temperature Uplink Low Temperature Fan Failure Scan Receiver Low Scan Receiver High No GPS Data No GPS Lock No GPS Fix GPS Antenna Current GPS Fix Filter Not Present Chassis Overheat Chassis Under Temp Software Abort Software Error Uncalibration AGC Disabled Property File Error DAS Failure Watchdog Timer Modem Not Responding User Login Password Changed CPU Boot Placed in Disabled Condition In Maintenance Mode Powerup and System Check Out Procedures - 10 - Section 3 Hardware Operations Test Point Locations and Values The CSI repeater, CS12-560-419, by design, has no external test points. The module is sealed with no user serviceable parts inside. Testing and configuration is done exclusively by interfacing the repeater with a laptop or desktop computer and using Text Menu Interface (TMI). This user interface will provide a complete status of the repeater. In most cases if all other components of the system prove to be working properly and the repeater is not, the user will need to return the unit to CSI for inspection and repair. See the Warranty and Repair Procedures in Section 3 of this manual. If the cover for module is removed by the user the warranty will be void and the cost of any needed repair will be the responsibility of the user. Indicator Lights This repeater was designed with only two external indicator lights. Both are approximately 3/4” diameter LEDs. Located on the Module face plate. The first LED labeled STATUS glows red as the repeater is powered up. When the unit completes all of it’s bootup procedures the LED will change color and glow green to indicate the system is operating normally. If the LED remains red it’s an indication of a problem and the user will need to check the system status using the TMI. The second LED is also located on the faceplate of the Module, and is labeled POWER. This light is designed only to show that the unit has DC current and will glow green when the unit is powered. Troubleshooting All cables should be checked for shorts and opens. The rooftop antenna (Donor Antenna), should be checked for damage. The DAS antennas should be checked for damage. If cables and antennas are acceptable and the problem persists, check repeater status using the Web based GUI or the TMI. See Alarm/ Action Matrix on the next page. Should the repeater fail, or if service is lost and the cause can not be determined from the steps above, the user should contact CSI Technical Support @ 1.877.844.4274. CSI will remotely access the repeater and advise the respondent of next step(s). -11 - Section 3 Hardware Operations Subsystem Alarm Name Alarm Type Send Shutdown E-mail Op Mode? Downlink Power Over Range Low Signal No Signal Out of Band Signal Over Range Out of Band Signal Synthesizer Error Dac Error DC Current High DC Current Low Oscillation Input Power High High VSWR Low VSWR FilterLoad Overcurrent Undercurrent Low Isolation High Temperature Low Temperature HighVSWR Low VSWR FilterLoad Overcurrent Undercurrent Oscillation Low Isolation High Temperature Low Temperature Fan Activation Fan Failure ScanRcvrLow ScanRcvrHigh No GPS Data No GPS Lock No GSP Fix Gps Antenna Current Gps Fix Filter Not Present Overheat Undertemp Software Abort Software Error Uncalibration AGC Disabled Property File Error DAS Failure Watchdog Timer Heartbeat Modem Not Responding Modem Not Connected Critical Routine Routine Routine Critical Routine Critical Critical Severe Severe Routine Routine Severe Severe Critical Severe Severe Routine Severe Severe Severe Severe Critical Severe Severe Routine Routine Severe Severe Routine Severe Severe Severe Critical Severe Critical Severe Severe Severe Severe Critical Severe Critical Critical Critical Critical Critical Informational Severe Routine Yes No No No Yes No Yes Yes Yes Yes No No Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes No No Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes No Uplink Power Common Hardware Alarms Downlink PA Uplink PA Scanning Receiver Alarms GPS Receiver Alarms Software Alarm Types Communications -12- Yes No No No Yes No Yes Yes Yes Yes No No No No Yes No No No Yes No No No Yes No No No No Yes No No No Yes Yes Yes No Yes No Yes No No Yes Yes Yes Yes Yes Yes Yes Yes No No Disable Unit? No No No No No No Yes Yes No No No No No No No No No No No No No No No No No No No No No No No No No Yes No No No Yes No No ?? No Yes Yes No No No No No No Section 3 Hardware Operations 1 Scope The warranty period for this product shall be 18 months (548 calendar days) from the date of the Purchaser’s Acceptance, plus any extended maintenance periods as specified in the order. During said period(s), CSI warrants that each repeater will be free of defects in material and workmanship. CSI’s sole obligation and the Purchaser’s exclusive remedy for any breach of warranty is limited to adjustments, repairs, or at the Purchaser’s option, replacement of a System or parts of a System thereof at no cost to the CSI. All exchanged Systems or System parts will become the property of the CSI. Servicing hereunder will be furnished by the CSI’s nearest service location. CSI shall perform this service at a time agreed to by the Purchaser. This warranty will not apply to a particular item if: (a) Adjustment, repair or replacement is required because of accident, neglect, misuse, failure of electric power, environmental controls, transportation or causes other than ordinary use, except that such adjustment, repair, or replacement is required due to actions caused by or the responsibility of CSI’s employees or CSI’s authorized agents; (b) The Purchaser fails to operate a System or follow operator-level maintenance procedures in accordance with the CSI’s recommendations; (c) Any person other than the CSI’s engineer or an authorized agent of the CSI modifies, adjusts, or repairs the product or performs any maintenance service other than routine operator-level maintenance without the CSI’s prior written consent. The warranty hereunder does not include: (a) Any furnished consumable supplies, (b) Painting or refinishing the product, (c) Electrical work external to the product, (d) Installation, maintenance or removal of alterations or attachments to the product except as provided by the original system design. CSI’s liability for breach of the above warranty will in no event exceed the purchase price of the Product(s) that has been paid by the Purchaser. 2 Product Hardware Warranty (Non-Software) (a) CSI represents and warrants to the Purchaser that upon delivery of a repeater to the Purchaser, all right, title and interest in the unit will pass to the Purchaser free of all liens, imperfections in title, claims, charges, restrictions, or other encumbrances. The CSI represents and warrants a repeater’s Hardware (specifically excluding the Product Software) as furnished shall be new, merchantable, free from defects in material and workmanship, fit for the ordinary purpose for which the product is used, shall not infringe on any U.S. Patent, and for the period specified in this document from the date a repeater is delivered and shall conform to this documents specifications. Should a unit not conform to the foregoing warranties, CSI shall repair or replace defective or nonconforming product. (b) During the warranty period, a defective repeater shall be either repaired on-site by CSI or returned to the CSI for repair or replacement at no charge or cost to the Purchaser. The Purchaser shall bear the risk of loss or damage until a unit is placed in the possession of the carrier. Unless otherwise agreed to by the CSI and the Purchaser, for a product that is returned to CSI for repair, CSI shall complete repairs and return repaired the product, or ship a replacement product, within three (3) days of receipt of defective repeater at CSI’s designated repair location. CSI shall bear the cost of transportation charges for shipment to CSI (FOB origin freight collect) of the product to be repaired or replaced. For return shipments from CSI to the Purchaser, CSI shall bear the risk of loss or damage during transit and shall prepay and bear the cost of transportation charges for shipment of the product that has been repaired or replaced. If a repeater returned is not defective, CSI shall promptly advise the Purchaser in writing of the determination and in such cases, CSI shall return product to the Purchaser at the Purchaser’s expense and risk in its “as received” condition. If a repeater is returned and is not in warranty, CSI shall promptly advise the Purchaser in writing of this determination and the charge to repair the product. In such cases, CSI shall repair the product if so instructed by the Purchaser in writing and charge the Purchaser for labor, parts, and shipping. (c) During the warranty period, if the Purchaser’s technical personnel attempt to determine whether or not a CSI repeater is the cause of service interruption and cannot identify and resolve the problem causing the interruption after communicating with CSI’s technical personnel via telephone or other suitable means, and the service interruption still exists, then the Purchaser may request that CSI begin on-site repairs as soon as possible, but in no event later than one (1) business day plus reasonable travel time after receiving the Purchaser’s request. If the problem is with CSI’s product, (software or hardware), such on-site repairs by CSI shall be at no charge to the Purchaser. Warranty and Repair Procedures - 13 - Section 3 Hardware Operations (d) During the Warranty period, if the service interruption still exists after compliance with (c) above, and the service interruption is caused by either CSI’s defective repeater(s) and/or CSI’s product that does not confirm to specification and CSI has been given a reasonable time frame, as determined by the Purchaser, to correct the service interruption, the Purchaser may return the product to CSI and receive a credit for the total purchase price of the Product or a completely new repeater, at the Purchaser’s option,. (e) Any replacement, repair, modification, installation or other service performed by CSI shall be warranted, commencing with the date upon which repaired product is returned to the Purchaser, for the remainder of the unexpired period of the warranty. (f) The warranties do not extend to a repeater to the extent that such repeater has been subjected to misuse, neglect, abuse, accident caused by the Purchaser or by a third party subsequent to the delivery of the unit, and such action is the cause of the damage or malfunction. 3 Product Software Warranty (a) CSI warrants that the Purchaser shall have quiet enjoyment of the Product Software and that the Product Software and the Purchaser’s use shall be free from claims of infringement, misuse or misappropriation of any intellectual property right during the term of the Purchaser license to Use the Software. As to Product Software which CSI does not have title, CSI warrants that has rights in the Software sufficient to permit the license of the Software to and that CSI has full right, power and authority to license the Software and other rights granted hereunder to Verizon Wireless. (b) CSI also warrants that the media containing the Software will be free from defects in material and workmanship and that all related services provided by CSI shall be rendered by qualified personnel who will perform the tasks assigned consistent with good professional practice and the state of the art involved. (c) CSI also warrants that there does not exists a copy protection or similar mechanisms within the Product Software, which will, either now or in the future, interfere with the operation of the Product. Furthermore, CSI warrants unless requested in writing by the Purchaser and the Purchaser approves response, or CSI advises the Purchaser in writing that it is necessary to perform valid duties under this attachment and authorized in writing by the Purchaser, any Product Software provided to the Purchaser by CSI for Use by the CSI or the Purchaser shall: · · · · contain no hidden files; not replicate, transmit or activate itself without control of an of an authorized person operating computer equipment on which it resides; not alter, damage or erase any data or computer programs without control of an authorized person operating computer equipment on which it resides; contain no encrypted imbedded key, node lock, time-out or other function, whether implemented by electronic, mechanical or other means, which restricts or may restrict Use or access to any programs or data developed under this Agreement, based on residency on a specific hardware configuration, frequency of duration of Use, or other limiting criteria (“Illicit Code”). (d) Where the Product Software is intended to be used in transaction processing or in the public switched network, CSI represents that nothing in the Product Software precludes the Purchaser form integrating a network management solution (including transaction processing and network monitoring) with the Product Software. (e) For the period specified beginning with the effective date of license of the Software, CSI represents and warrants that the Product Software will perform in accordance with specifications. If within one year (365 days) subsequent to the expiration of the warranty period CSI has not repaired the Product Software to perform in accordance with specification for any exception communicated in writing by the Purchaser to CSI during the warranty period, the Purchaser may order and CSI shall refund to the Purchaser the amount paid to it for the nonconforming Product Software. (f) CSI represents and warrants that if any portion of the Product Software is or becomes unusable, totally or in any respect, the Supplier will correct errors, defects and nonconformity and restore the Product Software to conforming condition without additional charge to the Purchaser. Warranty and Repair Procedures -14 - Section 3 Hardware Operations 4 Continuing Availability of Service and Parts (a) CSI shall, if requested by the Purchaser, provide the Purchaser with maintenance service, repair service and parts for the Product and Software, for a period of seven (7) years after extended Product and Service agreements have been discontinued by the Purchaser. If CSI is unable to supply such services and/or parts or CSI is unable to obtain an alternative source to provide such services and/or parts for the Purchaser, then the CSI shall, without obligation or charge to the Purchaser, provide the Purchaser with drawings or other documents required to either manufacture or buy such parts and the technical information or any other rights necessary for the Purchaser to manufacture or purchase such parts for the purpose of supporting the Purchaser’s customer base. (b) The technical information shall include, by example and not by way of limitation: · Manufacturing drawings and specifications of materials and parts comprising the replacement and repair parts and components; · Manufacturing drawings and specifications covering special tooling and operation; · A detailed list of all commercially available Continuing Availability of Service and Partsble parts and components purchased by CSI on the open market, disclosing the part number, name and location of the Company and price lists for the purchase; and · One complete copy of the source code used in the preparation of any software licensed or otherwise acquired by the Purchaser from CSI, provided however, that such source code shall remain the property of CSI and shall be separately licensed to the Purchaser for use by the Purchaser to support the Product. (c) In the event that CSI either (i) does not own the source code or (ii) does not have the rights to disclose such source code, then CSI shall disclose its licensor or owner of said source code and shall get the rights on behalf of the Purchaser. (d) Certain parts of the Product Software is subject to a licensing agreement and is sublicensed to the Purchaser. In the event of the inability to provide updates or continuing support of the application software at a reasonable cost, CSI shall assist the Purchaser in locating an alternative source. 5 Product Returns Please call 1.877.844.4274 to obtain a Return Material Authorization (RMA) number for product assessment and repair. Warranty and Repair Procedures - 15 - Section 4 Software Operations Local Communication Interface Ports To allow monitoring and control, the repeater is equipped with two ports that provide external communication access (1 Ethernet CAT-5, and 1 DB-9 serial). The Ethernet, CAT-5 port is provided as a primary communications port to the PC. One serial interface, COM, can provide communications to local PC. The DB-9 pin assignments of COM 1 conform to the standard Electronic Industries Association (EIA232) specification. A diagram of the pin descriptions is provided below for reference. Connecting a null modem cable to the COM 1 port and using a terminal emulation program with a PC will allow communication to the control processor’s Text Menu Interface (TMI) for trouble shooting and advanced diagnostics. Call CSI technical support for assistance if you need to access these advanced features or for further information. EIA232 Pin Specifications The diagram above is for reference only, it’s intended to provide a quick source for pinout information in the event it should be necessary to adapt your serial cable because of an unusual connector configuration. In the vast majority of cases this information will not be needed. General Operation Overview -16 - Section 4 Software Operations Ethernet The Ethernet AUI conforms to IEEE 802.3 and is capable of supporting 10/100 Mbps communications speeds. This port is used to provide access to the UI. Monitoring & Alarms There are no physical connections provided to exclusively and specifically communicate system or alarm status. Information with regard to system or alarm status is provided by the TMI accessible via the communication ports described earlier. Text Menu Interface Local Access Local access to the repeaters TMI, also known as the console interface, is made by connecting a serial cable (optional), as shown in figure 1, from the serial connector of the laptop to the serial port located on the top of the enclosure on the vertical surface facing the rear and near the heatsink. This connector is not labeled and is sealed with a special cover to maintain the integrity of the enclosure. This cover must be reinstalled after the serial port is used. In some cases, if the connector gender is not the same as shown in figure 1, an adapter (optional) as shown in figure 2 may also be required. Figure 1 Figure 2 General Operation Overview - 17 - Section 4 Software Operations Many terminal emulation programs will work if properly configured. In the following description, “TeraTerm” is used to establish the TMI session. This program is readily available via the Internet and is free from Ayera Technologies at: http://www.ayera.com/teraterm/ TeraTerm Pro Web works on Windows 95/98, 2000, XP. Here is the latest TeraTerm Pro Web release: Version 3.1.3, October 8, 2002. ttpro313.zip When the program is started, the screen to the right is displayed. Select the Serial radio button and press OK. Note: It may be necessary, in the System Properties section of the control panel; using Device Manager to determine what COM port your computer uses for the communications port. In this case it is COM 1. Pressing “OK” will open up a blank dialog screen. Go to the setup dropdown menu and select Serial port to make changes to the serial port setup. Configure the terminal program for the correct COM port, in this case COM 1 and 115200 baud rate as shown below. General Operation Overview -18 - Software Operations Section 4 Text Menu Interface Login Once the unit has completed its boot up and link initialization phases it will display the login prompt. The default username is “bandone” The default password is “csi1234”. Main Menu When “Set Parameters” is first selected the unit will ask for the maintenance mode login. (The default username for the maintenance mode is “csi” and the password is “csi1234”.) Set Parameters Menu Once the maintenance mode login is performed successfully the main menu will be displayed again but without the “(Disabled)” qualifier on the “Set Parameters” choice. Selecting (1) will display the Set Parameters Menu. General Operation Overview -19 - Section 4 Software Operations Telnet Session TCP/IP The diagram below shows the normal use of Crossed and Straight cables. Repeater Straight Cable Network Hub or Switch PC Straight Cable Crossed Cable PC Repeater Pin # Signal Transmit+ Transmit- Receive+ N/A N/A Receive- N/A N/A AT&T 258A White/Orange Orange/White or Orange White/Green Blue/White or Blue White/Blue Green/White or Green White/Brown Brown/White or Brown Straight Cable Crossed Cable Pin # Signal Receive+ Receive- Transmit+ N/A N/A Transmit- N/A N/A AT&T 258A White/Orange Orange/White or Orange White/Green Blue/White or Blue White/Blue Green/White or Green White/Brown Brown/White or Brown General Operation Overview - 20 - Section 4 Software Operations Remote access to the repeater may be gained through a LAN connection and a terminal emulation program for TCP/IP. As with the serial connection, many terminal emulation programs will work, if properly configured. In the following description, “TeraTerm” is used to establish the TCP/IP session. Also, it will be required that the network configuration of the computer and the repeater being controlled be set up with the same Sub Net and Sub Net Mask in order to establish a link. In other words, the IP addresses of both the computer used and the repeater must use the same group of IP address number sets. For example, the repeater ships with the default IP address of 192.168.1.100 and a Sub Net Mask of 255.255.255.0. In order to connect, the computer to be used for the link would normally need an IP address of something like 192.168.1.12 with a Sub Net Mask of 255.255.255.0, the same Sub Net Mask as the repeater. In this example note: the last digit of the IP address may be any number except 1,100 and 255. Configuring your PC is normally fairly straight forward but it does vary somewhat with the operating system involved. If you require assistance, contact your IT department and they will be able to set up your PC for you. When the TeraTerm program is started, the following screen is displayed. Change the default host IP address to the IP address of the repeater to be controlled. In the case of a new install, the default address is 192.168.1.100 and has been assigned at the factory. Select the service SSH. The TCP Port must be 22. Pressing the “OK” button may display the security alert shown below. Click the yes button and the first SSH2 Authentication Challenge screen is displayed. The user then types the username in the space provided. To make changes default user name is “bandone” . General Operation Overview - 21 - Software Operations Section 4 Press OK after entering the user name and the second SSH2 Authentication Challenge will be displayed. In the field provided, type the user name for the repeater to be changed. The default password is “csi1234” for all repeaters. After typing the password press OK and the main menu will be displayed as shown next. When “Set Parameters” is first selected the unit will ask for the maintenance mode login. (The default username for the maintenance mode is “csi” and the password is “csi1234”.) General Operation Overview - 22 - Section 4 Software Operations Set Parameters Menu Once the maintenance mode login is performed successfully the main menu will be displayed again but without the “(Disabled)” qualifier on the “Set Parameters” choice. Selecting (1) will display the Set Parameters Menu. General Operation Overview - 23 - Software Operations Section 4 ============== Set Parameters ============== (1) Link Configuration The “Link Configuration” menu is a collection of menu options that control the RF operating characteristics of a live system. ================== Link Configuration ================== (1) Adjust Gain The “Adjust Gain” option allows the user to control the total gain of the system. Valid gain settings range from 55 dB to 90 db. If the user selects to configure the downlink gain, the uplink gain will automatically be set to the same value. In order to override this condition, the user will have to select the uplink option and adjust the gain to the desired value. ----------Links: (1) downlink (2) uplink (r) Return to previous menu Link? ----------- User Gain: Setting 85.00 dB User Gain? 85.0 Auto Setting Uplink Gain to 85.00 dB To override, set Uplink gain separately (2) Select Active Filter The “Select Active filter” option allows the user to select the filter coefficients that have been loaded in the FPGA for test purposes. Please note that in order for this to work properly, the GPS task needs to be disabled otherwise the filter selection will be overridden by the current location of the system. ---------------FILTER settings: (1) select filter coefficient (2) show filter coefficient (r) Return to previous menu FILTER settings? Filter Coefficient Table filter index[1] = alB0F0-0 filter index[2] = alB0C0D0-0 filter index[3] = filter index[4] = filter index[5] = filter index[6] = filter index[7] = filter index[8] = General Operation Overview - 24 - Software Operations Section 4 filter index[9] = filter index[10] = filter index[11] = filter index[12] = filter index[13] = filter index[14] = filter index[15] = filter index[16] = ---------------FILTER settings: (1) select filter coefficient (2) show filter coefficient (r) Return to previous menu FILTER settings? select filter [1-16] (3) Filter Programming The “Filter Programming” option allows the user to select and load one of the loaded filter coefficients on the system. The user will be prompted to select which index the filter will be loaded into, one through sixteen or all for test purposes. Please note that in order for this to work properly, the GPS task needs to be disabled otherwise the filter selection will be overridden by the current location of the system. ------------Scan USB for files? (y,n): File names: (1) alA0B0-0 (2) alA0B0C0D0E0F0-WD (3) alB0-0 (4) alB0C0-0 (5) alB0C0D0-0 (6) alB0D0-0 (7) alB0F0-0 (8) alF0-0 (r) Return to previous menu Enter file number? Select filter ID [1-16] [99 = all] => ----------================== Link Configuration ================== (1) Adjust Gain (2) Select Active Filter (3) Filter Programming (4) PA Output Control (5) PA Oscillation Shutdown Control (6) PA Oscillation Timer Control (r) Return to previous menu -> (4) Power Amplifier Output Control General Operation Overview -25 - Section 4 Software Operations The “Power Amplifier Output Control” option allows the user to control the state of the power amplifier, ON or OFF. The setting overrides all other PA control tasks and is persistent across reboots. Care must be taken to insure the user is aware of the state of this setting so as to eliminate false keyed/de-keyed states. ----------------PA Output Enable: (1) off (2) on (r) Return to previous menu PA Output Enable? (r) Return to previous menu -> (2) Alarm Configuration The “Alarm Configuration” menu is a collection of menu options that control the alarming operating characteristics of a live system. =================== Alarm Configuration =================== (1) Alarm Masking The “Alarm Masking” option provide the user an ability to mask or unmask individual alarms based on the known operating characteristics of the environment that the unit is place in. Certain alarms will occur that do not directly affect the proper operation of the system and can therefore be masked. All alarms are still registered with the system regardless of the alarm state, user notification only takes placed on unmasked alarms. ============= Alarm Masking ============= (1) Show Alarm Configuration Displays the current mask state of all the alarms. (2)Set Duplicate Alarm interval (3) All Alarms Sets all alarms to a given mask state (ON/OFF). (4) Link Alarms Sets specific alarms of a particular link to a given mask state (ON/OFF). (5) HW/SW Alarm Configuration Sets specific alarms of a specific sub-system to a given mask state (ON/OFF). (6) Miscellaneous Alarms Sets specific miscellaneous alarms to a given mask state (ON/OFF). (r) Return to previous menu -> (2) Alarm Notification The “Alarm Notification” option provides the user the ability to configure the system to externally notify service personnel of alarm event s. ================== General Operation Overview - 26 - Section 4 Software Operations Alarm Notification ================== (1) Alarm Origin Tag The “Alarm Origin Tag” option provides user access to two settable parameters that are used to distinguish which system is reporting the alarm. The user should develop a relative scheme of naming individual units so that they can be easily identified by service personnel. The two parameters are included as part of the alarm information that is sent. ================ Alarm Origin Tag ================ (1) Host Name (2) Location (r) Return to previous menu (2) E-mail Alarm Configuration ========================== E-mail Alarm Configuration ========================== The “E-mail Alarm Configuration” option configures the e-mail alarm notification sub-system. (1) Show E-mail Config Displays the current configuration of the e-mail subsystem. (2) Enable/Disable msmtp Controls the state of the e-mail sub-system, the user must first enable msmtp in order for any e-mail alarms to be sent. (3) Set Recipient Address This option allows the user to configure up to five destination e-mail addresses that will receive system alarm events. It is best to leverage the management and configuration options of a destination mail server in order to setup a mail group of service personnel that will receive the alarms. (4) Heart Beat Email Configuration The system is capable of being configured to send out a heartbeat e-mail on a periodic basis. This function can be used to monitor the operational state of the system. (5) Send Test Email Provided that the e-mail sub-system is enabled and that there are configured destination addresses, this option will generate a test e-mail for diagnostic purposes. (6) E-mail Client Configuration This menu item provide access to user configurable options that setup the e-mail client (DSP system) for use with an authenticated e-mail server and account. General Operation Overview -27 - Section 4 Software Operations (r) Return to previous menu -> (3) SMS Message Configuration The “SMS Message Configuration” option configures the SMS (Short Messaging Service) l alarm notification subsystem. This option can be used to send alarm notifications to a user’s cell phone as text messages. (r) Return to previous menu -> (3) Watchdog Timer Configuration The “Watchdog Timer Configuration” option configures a hardware based watchdog timer. Once enable, the DSP software will periodically write to the watchdog timer thus preventing an unscheduled reboot. Certain alarms can be configured to inhibit this periodic write which in turn will reboot the system when they occur. ============================ Watchdog Timer Configuration ============================ (1) ON (2) OFF (3) Reset Reboot Counter (r) Return to previous menu -> (r) Return to previous menu -> (3) Networking Configuration The “Networking Configuration” menu contains three configuration menus. The “Local Network Configuration” provides access to the network connection that is made to the system via the Ethernet port located on the front panel of the unit. The “Remote Network Configuration” is used to configure the wireless modem(s) that are attached to the USB port of the SBC (single board computer) that controls the unit. The “SNMP Configuration” option is not used or supported in this version of product. ======================== Networking Configuration ======================== (1) Local Network Configuration The “Local Networking Configuration” menu allows the user to configure the Ethernet port to operate in one of three modes once enabled. If the unit is configured to have a static IP address, then the user must know what the characteristics of the network are that the unit will be connected to. In DHCP client mode, the unit will broadcast a request for an IP address from a properly configured DHCP server on the network. In DHCP server mode (default) the unit will assign itself an IP address of 192.168.1.100 and it will also listen for DHCP IP address requests. If the user connects a device (laptop) directly to the Ethernet port (cabling requirements may differ) the unit will issue an IP address of 192.168.1.90. The unit is currently capable of issuing one client address. This is done to limit cataclysmic events should the unit be connected to a network that already has a DHCP server. ---------------------CAUTION: Network reconfirmation may cause local and remote access interruptions. General Operation Overview -28 - Section 4 Software Operations ---------------------=========================== Local Network Configuration =========================== (1) enable (2) disable (3) set default static IP (192.168.1.100) (4) set labview calibration IP (192.168.1.69) (r) Return to previous menu -> (2) Remote Network Configuration The “Remote Networking Configuration” menu allows the user to configure the modem connected to the internal USB port of the SBC. This version of software is preconfigured to enable the default modem type installed in the unit and no user selection is necessary. ============================ Remote Network Configuration ============================ (1) enable modem (2) disable modem (3) Set Modem HeartBeat IpAddress (r) Return to previous menu -> (3) SNMP Configuration The “SNMP Configuration” menu is not supported for this revision of the product. ================== SNMP Configuration ================== (1) enable SNMP ============================ SNMP Configuration Parameter ============================ (1) Show SNMP Config (2) List NMS IP Addresses (3) Clear NMS IP Addresses (4) Create NMS IP Address List (5) Heartbeat Control (6) Heartbeat Frequency (7) Trap Control (8) Restart SNMP Daemon (9) Send Test Trap/Inform (r) Return to previous menu -> (2) disable SNMP (r) Return to previous menu (r) Return to previous menu (4) Log File Configuration The system is capable of storing it’s log files persistently on a periodic basis so that post mortem analysis can take General Operation Overview - 29 - Section 4 Software Operations place. The log files will be placed in the “/log” directory on the compact flash. The service personnel can then use off the shelf applications to extract the information to their laptop for review. ====================== Log File Configuration ====================== (1) Display Log Rotate Settings Displays the current settings of the log file rotation parameters. (2) Change Log Rotation Period This option allows the user to control the frequency of the log rotation task which will persistently store the log files based on size. (3) Change Minimum Log Size If an running log file exceeds this size (in bytes) the log file will be copied to the persistent storage location. (4) Change Number of Logs Rotated This parameter determines the number of log files of each type to maintain in persistent storage. Once the maximum number is reached, older files are discarded keeping only the most recent files. (5) Configure Log to File This option allows the user to write the current system status information to the appropriate log file on a periodic basis. (r) Return to previous menu -> (5) GPS Configuration The GPS sub-system is an integral part of the control of the DSP based system. During normal operating mode, the GPS receiver controls the selection of filters and the key state of the unit. The unit must first receive a valid GPS string from the satellites before the unit will perform properly. The following menu allows the user to examine and configure the GPS operating parameters of the unit. ================= GPS Configuration ================= (1) Set GPS Mode The GPS mode menu controls the operational state of the GPS receiver. The system is designed to run with a GPS emulator connected to COM3 (internal) for use s a test/debug mode. Additional menu items can be used to assist in the diagnosis of GPS related issues. ============ Set GPS Mode ============ (1) Enable GPS Receiver (default enabled) (2) Enable GPS Emulator (default disabled) (3) Disable GPS Receiver (default enabled) (4) Set GPS Source Device (default Network Host Client) (5) Set GPS ECP IP Address (default 192.168.1.101, 192.168.100) (6) Enable/Disable Amplifier (default enabled) (7) Set No Box Shutdown Mode (default enabled) (8) Set No Satellites Shutdown Mode (default enabled) (r) Return to previous menu -> New to the GPS mode menu controls is the ability to select the source of the GPS signal/mode used by system. General Operation Overview - 30 - Section 4 Software Operations The system is now capable of receiving a GPS signal via an Ethernet connection to a host system which itself is connected to a GPS source. This mode of operation is the default for the Acela AWS unit and it is configured to primarily access the Acela CELL unit and secondarily the Acela PCS unit. ============ Set GPS Mode ============ (1) Enable GPS Receiver (2) Enable GPS Emulator (3) Disable GPS Receiver (4) Set GPS Source Device (5) Set GPS ECP IP Address (6) Enable/Disable Amplifier (7) Set No Box Shutdown Mode (8) Set No Satellites Shutdown Mode (r) Return to previous menu -> (1) TTY Device (2) Network Host Client (3) Network Host Server Enter GPS Source and *reboot* system -> Also new to the GPS mode menu controls is the ability to select the IP address of the source of the GPS signal/ mode used by system. This is typically used in a laboratory environment when systems are not installed in the actual trains. ============ Set GPS Mode ============ (1) Enable GPS Receiver (2) Enable GPS Emulator (3) Disable GPS Receiver (4) Set GPS Source Device (5) Set GPS ECP IP Address (6) Enable/Disable Amplifier (7) Set No Box Shutdown Mode (8) Set No Satellites Shutdown Mode (r) Return to previous menu -> ------------------------------------ECP Management Server IP Address: * Enter up to 5 IP Addresses * Hit 's' to save new list * Hit 'r' to return to menu Setting (192.168.1.101) ECP Management Server IP Address 1? nnn.nnn.nnn.nnn GPS ECP addresses: (2) Set Time Interval ================= Set Time Interval ================= General Operation Overview - 31 - Software Operations Section 4 (1) Set Test Delay A user selected period used to delay (inhibit) the running of the GPS task. (2) Set GPS Receive Update Interval This parameter determines interval at which the GPS task acquires the GPS Receiver data. It can be in seconds and microseconds. The default is 1 sec. (3) Set Program Filter Interval The interval the GPS task programs the Filter. This is one of the parameters for programming the filter. The default value is 18 sec. Other parameters for filter programming are distance travelled after one filter is programmed. Except during the initial programming period when both filter are programmed. (4) Set No Data Timeout Interval The interval the GPS task can be without receiving any data from GPS Receiver. After which an alarm is sent and the PA is turned OFF. The default value is 25sec. (5) Set Polling Interval The interval for which the GPS task remains disabled after the PA is turned OFF. The default is 50 sec. (6) Set Emulator Update Interval The interval the GPS task reads the GPS Emulator data from the test port. The default is 15 sec. (r) Return to previous menu -> (3) Set Programming Distance ======================== Set Programming Distance ======================== (1) Set Distance To Program Filter The distance the train may travel after programming one filter at which the next filter is programmed. The Default is quarter mile (0.25 miles). (2) Set Maximum Distance To Program Filter The maximum distance the train can travel before programming the next filter. Default is 5 miles. (r) Return to previous menu -> (4) Set Maximum Count ================= Set Maximum Count ================= (1) Set Maximum No Box Count The maximum count for No Box (no fix data) before an alarm is sent and the PA is turned OFF. Default is 1500 ~ 25mins (2) Set Maximum No Satellite Count The maximum count for not enough satellites (minimum is 3) before an alarm is sent and the PA is turned OFF. Default is 1800 ~ 30mins (r) Return to previous menu -> (4) Set Test Location Used to select the location of the test filter set used for troubleshooting purposes. ================= Set Test Location ================= (1) Set Default Test Location (2) Set Box For Test Location (r) Return to previous menu General Operation Overview - 32 - Section 4 Software Operations -> (6) Read GPS Parameters Displays the current GPS configuration settings. ====================================================== GPS Parameters ====================================================== Run State Enabled Debug Msg Level PA Control Mode Enabled LookUp Table Size 10 Test Delay GpsRx Update Interval 1 secs:0 usecs Program Filter Interval 18 secs NoData Timeout Interval 25 secs Polling Interval 50 secs Emulator Update Interval 15 secs Max NoBox Count 1500 Max No Satellites Count 1800 NoBox Shutdown Mode Enabled No Satellites Shutdown Mo Enabled ====================================================== (7) Set Debug Message Level User selectable debug level, messages are sent to the “/var/log/dr610_2.log” file. (0) Display (1) Display (2) Display (3) Display Enter GPS No Msg Info Msg Debug Msg More Debug Msg Debug Msg Level (0)-> (r) Return to previous menu -> (6) Scan Receiver Configuration The scan receiver hardware is used to monitor the power levels of a set of frequencies for a given filter set. If the scanned power level is above the maximum threshold value, the task will de-key the unit until such a condition no longer exists. =========================== Scan Receiver Configuration =========================== (1) Scan Receiver Operation This option is used to control the state of the scan receiver task (ON/OFF). (2) Read Scan Receiver Parameters Displays the current configuration settings of the scan receiver task. (3) Channel Sample Count The number of samples per channel to acquire in order to compute an average power value. (4) Key/De-key Threshold The maximum power level in dBm which will cause the scan receiver task to de-key the PA. (5) PA Recovery Time The period of time in seconds that the unit will remain in a de-keyed state following an oscillation induced de-key. (6) De-key Sample Count General Operation Overview - 33 - Software Operations Section 4 The number of power readings to sample in order (7) Short/Fast Key Sample Count The number of power readings to sample in order nels. (See product specification document) (8) Long/Slow Key Sample Count The number of power readings to sample in order nels. (See product specification document) (9) Fast/Slow Key Delta Value The value in dBm that determines if a fast or slow (r) Return to previous menu to compute the rolling average of the current scanned channels. to compute the short/fast average of the current scanned chan- to compute the long/slow average of the current scanned chan- key decision is made. (r) Return to previous menu -> ============== Get Parameters ============== The “Get Parameters” menu is available to all users in order to view system status information and diagnose alarm information. (1) Link Status The “Link Status” option displays the current state of the system parameters. Information on this page is used to diagnose the health of the system. ============================================================================= Timestamp: 2012:12:21 - 15:20:16 UTC UTC ============================================================================= Uptime : 2 days 20 hours 46 minutes ============================================================================= Power (dBm) DNLINK UPLINK ============================================================================= IN-BAND INPUT -83.42 -65.58 COMPOSITE INPUT -50.70 -56.66 MEASURED OUTPUT 3.58 21.42 CALIBRATED OUTPUT 27.40 33.00 MAXIMUM OUTPUT 27.40 33.00 VSWR ---++++ ============================================================================= AGC Control (dB) ============================================================================= MODE ON ---/--0.00 0.00 ============================================================================= Status ============================================================================= VOLTAGE OK OK TEMPERATURE OK OK SOFTWARE OK OK HARDWARE OK OK OSCILLATION OK OK OVERRANGE OK OK CALIBRATION OK OK ============================================================================= General Operation Overview - 34 - Section 4 Software Operations DC Current ============================================================================= AMPERAGE 3.54 ============================================================================= Temperature (Celsius) ============================================================================= CPU 40.06 new item, displays the temperature of the Single Board Computer FPGA 53.75 ============================================================================= Power Amplifier ============================================================================= STATUS ON AMPERAGE 0.89 6.31 TEMPERATURE ---66.84 ============================================================================= Fan Configuration ============================================================================= STATE OFF OFF STATUS OK OK ============================================================================= System Configuration ============================================================================= GAIN (dB) 87.00 87.00 FILTER alB0F0-0 ============================================================================= (2) System Events The “System Events” option displays the current list of system alarms. Alarm statistics are maintained in the “Show Counts” option. ============ System Events ============= (1) List (2) Show Counts (3) Clear (r) Return to previous menu (3) System Information The “System Information” option displays the current state of the non-RF parameters. ====================================================== System Info: 2008:11:18 - 20:54:46 UTC ====================================================== Location Software_lab System Type CSI-DSP85-A Board Type PCS - Rev. B Carrier Verizon EVDO SW Version 02.03.00 RC5 Serial Number CDJ80150-000148 Item Number CS10-369-xxx Date Built 10/08/2008 Watchdog Timer Enabled General Operation Overview - 35 - Software Operations Section 4 ====================================================== Local Area Network: ====================================================== Hostname csi-acela-beta5 Boot Protocol dhcp IP Address 192.168.1.90 MAC Address ====================================================== Wide Area Network: ====================================================== PPP Enabled YES Modem Type CDMA PPP0 Address 166.143.7.196 PPP0 MAC Address 166.143.7.196 PPP1 Address 0.0.0.0 PPP1 MAC Address ====================================================== SNMP Configuration: ====================================================== Enabled YES Traps/Informs NO Heartbeat NO ====================================================== MODEM Status Information ====================================================== MODEM #1 RSSI (dBm) -69 (OK) Registration Sts Modem has registered Phone Number 9084425314 Current Band Cellular Sleep System ID 28 Network ID Temperature (C) 36 ====================================================== GPS Location Data ====================================================== Run State Enabled Latitude 42.997005 Longitude -71.468246 Filter ID Filter Name pcR0A0D0B0E0F0C0-Wid Location Manchester BTA 500 Satellite Count NoBox Count Searching Count 0 ====================================================== Scan Receiver MHz avg dBm ====================================================== Run State Enabled Dekey Limit -65.00 Filter ID Channels 11 General Operation Overview - 36 - Software Operations Section 4 Channel-1 1971.25 -110.58 Channel-2 1972.50 -110.38 Channel-3 1973.75 -110.72 Channel-4 1975.00 -110.82 Channel-5 1976.25 -110.00 Channel-6 1977.50 -111.49 Channel-7 1978.75 -111.35 Channel-8 1980.00 -111.06 Channel-9 1981.25 -110.67 Channel-10 1982.50 -110.96 Channel-11 1983.75 -111.01 ====================================================== (4) Link Status Loop The “Link Status Loop” option displays the current state of the system on a periodic basis in the form of a parse able string. Mode ‘0’ displays a list of system parameters on a periodic basis. Mode ‘1’ displays a list of system parameters every time the filter selection changes. Mode ‘2’ displays a list of scan receiver parameters on a periodic basis. Mode ‘3’ displays a list of power detector values on a periodic basis. Enter loop delay -> 2 Display Mode (0 = normal, 1 = BTA changes, 2 = ScanRcvr RSSI, 3 = power) -> 0 2012:12:21, 16:50:26 UTC, 2:22:16, 48.00, 48.00, 43.18, 0.00, 0.49, Providence, 42.038258, -71.216042, 8, 2, 1, 2, alA0B0-0, alB0F0-0, 1, 0x10, 1, -120.86, -92.38, -50.94, -56.66, -33.86, -5.38, 87.00, 87.00, 0.0, 0.0, OK, OK, OK, OK, OK, OK, OK, OK, OK, OK, OK, OK, NM, 2, -65.00, 1, 8, 4, 12, -13.61, -13.62, -13.59, 12, 1, 2120.62, -13.82, 2, 2121.88, -13.67, 3, 2123.12, -13.87, 4, 2124.38, -14.23, 5, 2125.62, -14.50, 6, 2126.88, -14.64, 7, 2128.12, -14.52, 8, 2129.38, -14.56, 9, 2130.62, -14.62, 10, 2131.88, -14.60, 11, 2133.12, -14.64, 12, 2134.38, -14.64, General Operation Overview - 37 - Software Operations Section 4 The repeater’s operating software have two modes, an Operational mode and a Maintenance mode. These are described below. Operational Mode: Upon power up, the System will begin operation in the Operational Mode. Using a “Band Switching Algorithm” the repeater will not key until a GPS position fix is obtained and the unit is within an Area Definition. Once GPS position fix is obtain the repeater will begin operation based on the Area Definitions “Channel Power Measurement and Keying Decision” and “Low Isolation Detection and Protection” algorithms. The operational software will continuously monitor the system’s environment and make the necessary adjustments to keep the product operating with specifications and within the normal operating range of the Product and FCC Type Certification. System Status The Operating Software provides real time status data that reports the state of the repeater. This status contains: Timestamp System Up Time Software Version System Serial Number Model Number Item Number Location Modem Signal Strength Modem Registration Status Modem Phone Number Modem Current Band Modem System ID Modem Network ID Modem Temperature Modem Band Type Satellite Count Active Filer NoBox Count In-band input Searching Count Measured Output Scan RX Run State Composite Input DeKey Limit AGC Mode Scan RX Filter ID AGC Attenuation # of Channels GPS RunState 1 -10 Channel Freq’s & SSI Latitude Longitude RF Alarms: System Alarms: Filter ID Over Range Synthesizer Lock Filter Name Oscillation Voltage Location VSWR Temperature BTA Out of Band Overdrive Software Low Signal Hardware No Signal Currently System events are stored to a Log File. In future releases, with the exception of the System Serial Number and System Identifier, The Real Time Status of the Product will be saved to nonvolatile memory for retrieval. The nonvolatile memory will be able to store 48 hours of Status data, with up to 6 complete status records per minute. The interval that the status records are saved will be user defined. The Operating Software will also record to nonvolatile memory and make available to a user in the Maintenance Mode: A count and time stamp each time the processor is booted. A count and time stamp of each time the operating software is placed into the Maintenance Mode, and the User ID of the operator that performed the action. A count and time stamp each time the Watchdog Timer is activated, and the associated debugging information available at the time of activation of the Watchdog Timer. The count and time stamp of any activation of the “Low Isolation Detection and Protection Algorithm” as defined in attachment C of this document. Alarms The Operating Software has the ability to monitor a System for conditions that are out of normal operation, triggering an alarm event. The Operating software in conjunction with the Communications Subsystem is capable of sending alarm messages via E-mail using standard SMTP and POP3 protocols to a User Provisioned e-mail account. Each Alarm defined has these User Provisioned Capabilities.: Disable the System: The Operating software can disable the System (prohibit Keying) until the alarm condition is cleared. Alarm Filter Conditions: A Filter Condition (such as X number of occurrences per hour) to the alarm to prevent false or un-useful notifications if provisioned. Send an Alarm Message: The Operating Software can send a notification via message E-mail through the Communications Subsystem if provisioned. Alarm Clear Message: The Operating Software can send an alarm clear message when an alarm condition clears if provisioned. General Operation Overview - 38 - Section 4 Software Operations Maintenance Mode The repeater has, in addition to it’s normal “Operational Mode” a “Maintenance Mode”. After system boot up this mode can be accessed in the TMI only by typing the user name and password of service. This mode of operation provides all the same menus and features as shown in the software overview on previous pages except that upon entering the Maintenance Mode, the product will de-key and await instructions from a connected user. During the Maintenance Mode of operation the Operating Software supports: Manual operation of the Key/De-Key function. Manual operation of the Area Definition Switching function. Manual Setting of the gain setting in both the Uplink and Downlink Directions Retrieval of all current User Provisioned Settings from the Product Retrieval of the Current Version of software in the Product Setting of all User Provisioned Settings Retrieval of logged Status data Retrieval of boot counts, Maintenance Mode entry counts, Watch Dog timer events with debugging data, and Low Isolation Detection and Protection events. The Ability to Disable and Enable the System. A Method to automatically place the System back into operation upon the discontinuance of the Maintenance session. A Method to automatically place the stem back into operation after a User Provisioned time limit of inactivity in the Maintenance Mode. Ability to load Operating Software into the repeater’s processor. Ability to perform a “soft” reset of the processor. General Operation Overview - 39 - Section 4 Software Operations Terms used in this manual AGC= Automatic Gain Control CBC= Cross Band Coupler CSI= Cellular Specialties, Inc. DAS= Distributed Antenna System DC = Direct Current DHCP= Dynamic Host Configuration Protocol DL = Down Link FCC = Federal Communications Commission FPGA= Field Programmable Gate Array GPS = Global Positioning System GUI = Graphical User Interface IP = Internet Protocol IT = Information Technologies LAN = Local Area Network LED= Light Emitting Diode LNA = Low Noise Amplifier PCS = Personal Communications Service RF= Radio Frequency SBC= Single board Computer SNMP= Simple Network Management Protocol TMI= Text Menu Interface UL = Up Link USB = Universal Serial Bus VSWR = Voltage Standing Wave Ratio General Operation Overview - 40 - Section 4 Software Operations Indicator Lights 11 Installation 6 Repeater Index LED 40 Local Communication Interface Ports 16 Login 19 AGC 6, 40 Alarm Notification Message 10 Alarms 10 Band Switching Algorithm 10 Block Diagram of the Major Components 4 Continuing Availability of Service and Parts 15 CPU 40 Crossed Cable 20 CSI 40 Main Menu 19 Maintenance Mode 39 Module Face Plate Configuration 5, 8, 9 Module Face Plate View 5 Module Interconnection Diagram 7 U Module Label Locations 7 USB 40 Module Side View 5 Module Top View 5 Monitoring & Alarms 17 Normal Operation 10 null modem adapter 17 DAS 40 DC IN 10 DHCP 40 Operational Mode 38 EIA232 Pin Specifications 16 ERP 40 Face Plate Dimensions 8 FPGA 40 General Operation Overview 16 GPS 10 Hardware Configuration 5 Hardware Operations 11 Important Safety Information Telnet Session 20 Telnet Session (Remote Access) 20 terminal emulation programs 18 Terms used in this manual 40 Text Menu Interface 17 Top View Dimensions 9 Set Parameters Menu 19, 23 SNMP 40 Software Operations 16 Straight Cable 20 System Alarms 38 System Status 10 Physical Installation Into The Train Power Up 10, 11 Powerup and System Check Out Procedures 10 Product Hardware Warranty 13 Product Software Warranty 14 RF 40 RF Alarms 38 RF and Power Cabling 6, 7 SBC 40 Section 2 7 Section 3 10 Section 4 16 serial cable 17 General Operation Overview - 41 - Warranty and Repair Procedures 13 warranty period 13 Web based GUI Session 17 Notes - 42 - Notes - 43 - D960-1042-006 rev 007
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Create Date : 2015:08:20 18:05:28-04:00 Creator Tool : Microsoft® Word 2013 Modify Date : 2015:08:21 14:36:29-04:00 Metadata Date : 2015:08:21 14:36:29-04:00 Format : application/pdf Creator : KALBE Title : 960-1042-006 Manual John r006.indd Producer : Microsoft® Word 2013 Document ID : uuid:5643a990-173d-4a73-b922-0f44a226d35a Instance ID : uuid:cd785c7a-7585-45d7-b469-56317c331f89 Page Count : 44 Language : en-US Author : KALBEEXIF Metadata provided by EXIF.tools