WiSilica WCA2CS WCA2CS User Manual WCA2CS Ver1 1 090818x

WiSilica, Inc. WCA2CS WCA2CS Ver1 1 090818x

User manual

Download: WiSilica WCA2CS WCA2CS User Manual WCA2CS Ver1 1 090818x
Mirror Download [FCC.gov]WiSilica WCA2CS WCA2CS User Manual WCA2CS Ver1 1 090818x
Document ID4049046
Application IDWqvTsC8i+p+8d3MP13+ZBw==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize48.83kB (610398 bits)
Date Submitted2018-10-25 00:00:00
Date Available2018-10-25 00:00:00
Creation Date2018-08-09 13:09:34
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2018-08-09 13:09:34
Document TitleMicrosoft Word - WCA2CS Ver1.1_090818.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: Admin

WISILICA NETWORK LIGHTING | CONTROL SERIES
Table of Contents
1.
Block Diagram..................................................................................................................................................... 3
2.
Specifications ....................................................................................................................................................... 3
3.
Device Dimensions (mm) ................................................................................................................................ 5
4.
Connector Description ..................................................................................................................................... 5
5.
Wiring Diagram .................................................................................................................................................. 6
6.
Use Cases .............................................................................................................................................................. 6
7.
User Precautions ................................................................................................................................................ 7
WISILICA NETWORK LIGHTING | CONTROL SERIES
1. Block Diagram
2. Specifications
Symbol
Min
Input Voltage
Vin
110
Input Current
Iin1
Watt
Electrical
Power consumption
Input Frequency
Protection Class
Inrush Current
50
Typ.
Max.
Unit.
Remarks
277
Vac
Rated Input voltage
60
100
mA
@ Max RF transmitting
1.0
60
Hz
Built-in
Class II
Suitable for class I and II
luminaries
20
Surge transient Protection
Active Power
kV
@Line to Line: Bi-Wave
Leakage Current
0.5
mA
@Rated input voltage
Aux power
12V
120mA
Sensor Interface
UART
WISILICA NETWORK LIGHTING | CONTROL SERIES
Analogue Dimming Output
Dimming Output1
Vadimo1
10
Max output tolerance ±5%
Dimming Output2
Vadimo2
10
Max output tolerance ±5%
15
mA
For dimming max output
100
Output Current
Dimming Range
Dimming Resolution
Dimming Curve
Linear
Cut Off Voltage
Bluetooth
Frequency Range
2400
TX Power
bit
2483.5
dBm
Conductive
dF2
-25
25
kHz
Frequency Deviation
±225
±275
kHz
150
kHz
48
mA
2483
kHz
-37
mA
-75
dBm
30
TX current
Receive Frequency
2400
Rx Current
Receiver Sensitivity
-86
Symbol
Min
Ambient Temperature
ta
Storage Temperature
ts
Environmental
Typ.
Max.
Unit.
-20
50
ºC
-20
70
ºC
85
Relative Humidity
IP Rating
Dimensions
Net Weight
Dimming
Dimming Control 1
80
Type
0 – 10V
WISILICA NETWORK LIGHTING | CONTROL SERIES
Note
Analog
Programmable
MHz
Frequency Drift(Max)
Carrier Frequency offset
100 steps
Total current@ Max Tx power
Total Current @Rx Mode
Remarks
IP20
Indoor use only
175*34*30
mm
L x W x H (mm)
90
100
T.B.D
3. Device Dimensions (mm)
Case Material : 5VA
4. Connector Description
PIN
SYMBOL
COLOR
DESCRIPTION
Neutral Line
Black
AC Input Neutral
Neutral Load
Grey
110-277V ~(Line)
Line
Yellow
110-277V /5Amps
Load
Red
110-277V /5Amps
PIN
SYMBOL
COLOR
DESCRIPTION
ADC input
Grey
CH1 0 to 10V ADC INPUT
ADC input
Grey
CH2 0 to 10V ADC INPUT
RX
Grey
UART
TX
Grey
UART
GND
Grey
12V Ground Output
12V
Grey
Supports up to 1.4W
5. Wire Description
PIN
SYMBOL
COLOR
DESCRIPTION
CH1+
Purple
CH1 0 to 10V Analog Output
CH2+
Blue
CH2 0 to 10V Analog Output
GND
Grey
12V Ground output
12V
Red
12V
WISILICA NETWORK LIGHTING | CONTROL SERIES
6. Wiring Diagram
7. Use Cases
1.
Controlling Intensity and CCT of LED bulb
2.
Controlling LED bulb with Sensor Inputs
3.
Controlling external load upto 5A
WISILICA NETWORK LIGHTING | CONTROL SERIES
8. User Precautions
•
•
•
Observe the correct polarity of output terminal.
Avoid input voltage exceeds the maximum rating, which will cause damage to the circuit and
result in malfunction
Static electricity or surge voltage may damage the components inside LED Driver, to avoid this
please follow the proper anti-electrostatic working process.
9. FCC Statement
•
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•
Consult the dealer or an experienced radio/TV technician for help.
•
Caution: Any changes or modifications to this device not explicitly approved by manufacturer
could void your authority to operate this equipment.
•
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
10. RF Exposure Information
•
The device has been evaluated to meet general RF exposure requirement. The device can be use
d in portable exposure condition without restriction.
WISILICA NETWORK LIGHTING | CONTROL SERIES

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 7
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2018:08:09 13:09:34
Modify Date                     : 2018:08:09 13:09:34
Title                           : Microsoft Word - WCA2CS Ver1.1_090818.docx
Creator                         : PScript5.dll Version 5.2.2
Author                          : Admin
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AG4N-WCA2CS

Navigation menu