Wireless 2000 RF and UWB Technologies 20000310 PAM 3000 Bed Sensor Panel User Manual 100 100 19 04

Wireless 2000 RF & UWB Technologies Ltd. PAM 3000 Bed Sensor Panel 100 100 19 04

Contents

Instalation and Maintenance Guide

Download: Wireless 2000 RF and UWB Technologies 20000310 PAM 3000 Bed Sensor Panel User Manual 100 100 19 04
Mirror Download [FCC.gov]Wireless 2000 RF and UWB Technologies 20000310 PAM 3000 Bed Sensor Panel User Manual 100 100 19 04
Document ID990565
Application IDL5WCcO7eMnCWXE9oDnzM2A==
Document DescriptionInstalation and Maintenance Guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize14.37kB (179640 bits)
Date Submitted2008-08-26 00:00:00
Date Available2008-12-29 00:00:00
Creation Date2008-07-14 12:11:13
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2008-07-14 12:11:13
Document TitleMicrosoft Word - 100.100.19.04.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: Elia

PAM™3000
Patient Assessment Monitor
Installation and
Maintenance Guide
DOCUMENT TITLE
Installation and
Maintenance Guide
DOCUMENT #:
100.100.19.04
DOCUMENT REVISION #:
04
REVISION HISTORY
Revision
00
Date
09.Mar.2006
01
07.Apr.2008
02
22.Apr.2008
03
03
29.May.2008
14.Jul.2008
Reason For Change
Preliminary Draft
Rev history and FCC standards added,
Environmental conditions changed as in CSA
report
P/N added to “System Hardware Installation”,
troubleshooting table added
Grammatical and spelling errors fixed
BSI&CSA logo removed, FCC notice included
Author
E. Gavrilovich
Eli A
Eli A
Eli A
Eli A
Proprietary Information
This document contains proprietary information which is protected by copyright. All rights reserved. Reproduction, adaptation,
or translation without prior written permission is prohibited, except as allowed under the copyright laws.
Wireless 2000 RF & UWB Technologies Ltd.
2421 Alpha Avenue
Burnaby, BC, V5C 5L2
Canada
Document p/n 100.100.19.04
Page 1 of 7
Rev 04
PAM™3000
Patient Assessment Monitor
Installation and
Maintenance Guide
1 Introduction
This Guide provides safety information, maintenance guidelines and cleaning
instructions for the PAM™3000 Patient Assessment Monitor system.
2 System Description
PAM™3000 is for use in the US and Canada. The PAM™3000 system consists of
Bed Sensor (200.003.10.00), RBS Repeater Base Station (200.001.10.00), CBS
Central Base Station (200.002.10.00) and software.
3 System Hardware Installation
3.1 Installing the Bed Sensor
Regulatory Notice
This equipment may only be operated indoor. Operations
outdoor is in violation of 47 U.S.C. 301 and could subject the
operator to serious legal penalties
FCC information
Product Name: PAM 3000 Bed Sensor Panel
Model number: WHQ20000310
3.1.1 Step 1: Power Supply
Find the power supply in the shipping box and unpack it.
Only the approved Power Supply (Wireless2000 p/n 375.001.10.00) and
Power Cord (Wireless2000 p/n 506.001.10.00) shipped with PAM™3000
should be used.
Attach the power supply to the closest to the headboard tubular crossbar of the bed
frame with the Velcro ties as shown. Route DC output cable as shown and fasten it
with the Velcro ties to the bed frame. The DC plug should be placed near the top
Document p/n 100.100.19.04
Page 2 of 7
Rev 04
PAM™3000
Patient Assessment Monitor
Installation and
Maintenance Guide
section of the bed surface, as shown. Route AC power cord as shown and fasten it
with the Velcro ties to the bed frame. Plug the AC power cord into the approved AC
wall outlet.
3.1.2
Step 2: Bed Sensor
Unpack the bed sensor. Record its serial number and the room number for the
location identification during the admission procedure. Pull up or slide down the bed
mattress to expose the top section of the bed. Place bed sensor on the bed 18” (46
cm) away from the headboard and ensure that bed sensor’s plastic cover is facing
up and the bed sensor’s DC power jack is oriented toward the footboard. Insert DC
plug of the power supply into the DC jack of the bed sensor and tighten the outer
ring of the plug to prevent its accidental unplugging.
3.1.3 Step 3: Calibration
To perform successful self-calibration procedure, ensure that the bed is vacant and
there is no motion within 1 meter from the bed for 10 minutes. The bed sensor is
now calibrated and ready for integration into the PAM system.
3.2 Installing the Repeater Base Station (RBS):
The locations to install the RBSs and the necessary number of RBS
units were determined during the Initial Facility Assessment (IFA).
Please consult the IFA Report.
Install the RBS up on the wall near the ceiling by using mounting screws supplied.
Attach the DC plug of the DC power adapter (supplied) to the RBS DC jack and
insert the AC plug into the nearest AC wall receptacle. Alternately, the RBS may be
mounted above the suspended ceiling.
Document p/n 100.100.19.04
Page 3 of 7
Rev 04
PAM™3000
Patient Assessment Monitor
Installation and
Maintenance Guide
3.3 Installing the Central Base Station (CBS):
The system requires only one CBS unit per facility’s floor.
Install the CBS by plugging its cable into the USB port of designated PC and placing
the unit on the desk next to PC. For proper operation ensure that the label on the
CBS enclosure is facing up. Improper orientation of the CBS may greatly decrease
system’s communication range.
4 Replacement Parts List
200.003.10.00 – Bed Sensor
200.001.10.00 – Repeater Base Station
200.002.10.00 – Central Base Station
5 Technical Information
Model: PAM™3000
Type of protection against electric shock: Class 1
Degree of protection against electric shock: Type BF, Applied part
6 Environmental Specifications:
6.1 Operating
Ambient temperature range: 10°C to 40°C (50°F to 104°F)
Relative humidity: 30% to 75%, non-condensing
Altitude: Sea level to 3000m max (10,000 Ft)
6.2 Transport and Storage
Ambient temperature range: -10°C to +60°C (+14°F to 140°F)
Relative humidity: 5% to 95%, non-condensing
Altitude: Sea level to 12,000m (40,000 Ft)
Document p/n 100.100.19.04
Page 4 of 7
Rev 04
PAM™3000
Installation and
Maintenance Guide
Patient Assessment Monitor
6.3 Applicable Requirements:
UL 60601-1 (1st Edition) Medical Electrical Equipment, Part 1: General
Requirements for Safety
IEC 601-1:1988 + A1:1991 + A2:1995
Safety of Medical Electrical Equipment, Part 1: General Requirements for Safety
IEC/EN 60601-1-2 Medical Electrical Equipment, Part 1: General Requirements for
Basic Safety and Essential Performance. Collateral standard, EMC Safety
With respect to ELECTRICAL SHOCK, FIRE, MECHANICAL and OTHER
specified hazards in accordance with
CAN/CSA C22.2 No.601.1- M90
Safety of Medical Electrical Equipment, Part 1: General Requirements for Safety
CAN/CSA C22.2 No.601.1S1-94
Supplement No. 1-94 to CAN/CSA C22.2 601.1-M90
CAN/CSA C22.2 No.601.1B-98
Amendment 2 to CAN/CSA C22.2 601.1-M90
EN 61000-4, IEC 61000-4 in accordance with FCC part 15/B, 15/C, 15/F
Power Supply complies with UL60601-1, UL60950-1, CSA C22.2 601-1, CSA C22.2
60950-1, EN60601-1 and EN60950-1.
Power Supply Cord complies with UL 60601-1.
7 Maintenance Schedule
Maintenance
Frequency
Inspect the power cord
Daily (when not in use)
Cleaning
As needed
Safety checks according
to IEC 601-1
Document p/n 100.100.19.04
At least once every two
years, after any repairs
Page 5 of 7
Procedure
Examine the AC power
plug for damage. Make
sure that the prongs of
the plug do not move in
the casing. If damaged,
replace the Power Cord
with the appropriate
Wireless 2000 Power
Cord.
See “Cleaning
Procedure”
See your qualified
service personnel for
Rev 04
PAM™3000
Patient Assessment Monitor
Functional Testing
Performance Assurance
Installation and
Maintenance Guide
or as needed
When functional defects
in measurements are
suspected
At least once every year,
or as needed (when
functional defects in
measurements are
suspected)
additional information
See your qualified
service personnel for
additional information
See your qualified
service personnel for
additional information
8 Cleaning Procedure
Warning:
- Do not immerse the Bed Sensor, RBS or CBS in liquid or use caustic
or abrasive cleaners.
- Do not spray or pour any liquid on the Bed Sensor, RBS or CBS.
- Do not allow any liquid to penetrate connectors or openings in the Bed
sensor’s chassis.
To clean the Bed Sensor, dampen a cloth with commercial, non-abrasive cleaner
and wipe off the top and sides of the plastic cover.
If liquid is accidentally spilled on the Bed Sensor, clean and dry it thoroughly before
reuse.
If in doubt about the Bed Sensor’s safety, refer the unit to qualified service
personnel.
9 Troubleshooting
The table below will help intended user to troubleshoot possible problems without
any external help from Wireless2000’s tech-support personnel. However, if any
technical problems appeared, save the description of the problem into the log file for
the further investigation.
Problem
1) “No Data” received on GUI/ No Communication
Possible cause
a) Bed Sensor’s power
Document p/n 100.100.19.04
Page 6 of 7
Solution
-check power adaptor to
Rev 04
PAM™3000
Patient Assessment Monitor
Installation and
Maintenance Guide
unplugged
b) RBS’s power unplugged
c) RBS is not associating with
CBS
make sure power jack is
connected. If it was
disconnected, plug it in
and proceed with
calibration routine (See
System Hardware
Installation Step 3 for
reference).
-check LED indicator on
RBS. If it is “OFF” (no
light) than make sure
RBS’s Power Supply is
connected. Reconnect it in
case it was unplugged.
Otherwise, if it is
connected, call
Wireless2000’s techsupport personnel.
-Reset the RBS by
disconnecting its power
jack and connecting again.
2) “Error” display on the monitor (GUI)
Possible cause
d) Failed calibration of Bed
Sensor
-Unplug Bed Sensor and
plug it back. Make sure
there is no motion one
meter within the Bed
Sensor for at least 1
minute.
©Copyright 2007 Wireless 2000
All Rights Reserved
Printed in Canada
Document p/n 100.100.19.04
Page 7 of 7
Rev 04

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 7
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2008:07:14 12:11:13
Modify Date                     : 2008:07:14 12:11:13
Title                           : Microsoft Word - 100.100.19.04.doc
Creator                         : PScript5.dll Version 5.2.2
Author                          : Elia
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WHQ20000310

Navigation menu