Wireless eSystems CC2500DIPOLE Student Assessment Remote User Manual UltraLiteTechManualwcover
Wireless eSystems, Inc. Student Assessment Remote UltraLiteTechManualwcover
Contents
- 1. Lite Remote User Manual
- 2. Touch Remote User Manual
- 3. Ultralite Remote User Manual
Ultralite Remote User Manual
iRespond®- UltraLite Technical Manual Wireless eSystems Table of Contents UltraLite Base Unit -------------------------------------------------------- 1 Change the Channel --------------------------------------------------1 Adjust Power Output -------------------------------------------------1 Turn On/Off Channel Scan ----------------------------------------- 2 Setting Base UID -----------------------------------------------------2 Adjusting Base Offset ----------------------------------------------- 3 Turn on in Programming Mode ------------------------------------ 3 UltraLite Remote Unit ---------------------------------------------------- 4 Login by Pin ---------------------------------------------------------- 4 Login Anonymously ------------------------------------------------- 4 Answer Multiple-Choice Questions ------------------------------- 4 UltraLite/Lite Base Unit Change the Base’s Channel 1. Press the power button 2. Immediately press F1 screen. to turn on the Lite base. while Wireless eSystems scrolls across the base’s 3. When Device Address appears press ENT altered). 4. Select ENT . (This number should not be at Output Power. 5. Output Channel should now be displayed. 6. Use the up 7. Press ENT and down buttons to change the base’s channel. four more times to save and exit configuration mode. 8. The base will automatically shut off. Adjust the Power Output The Power Output is set to 0 when shipped. The power output may be changed to help strengthen the RF signal when transmitting to many remotes or at far distances. 1. Press the power button 2. Immediately press F1 screen. to turn on the Lite base. while Wireless eSystems scrolls across the base’s 3. When Device Address appears press ENT altered). 4. Use the up 5. Press ENT and down . (This number should not be buttons to change the power. five more times to save and exit configuration mode. 6. The base will automatically shut off. iRespond UltraLite Technical Manual 1 Turning Channel Scan On/Off It is best for the base and remote units to be on the same channel. However, channel scanning can be used to allow the base unit to find the best channel with the least amount of noise. To communicate with a base with channel scanning on, remote units must be configured with channel hopping on. 1. Press the power button 2. Immediately press F1 screen. to turn on the Lite base. while Wireless eSystems scrolls across the base’s 3. When Device Address appears press ENT altered). . (This number should not be 4. Select ENT at Output Power. 5. Select ENT at Output Channel. 6. Select ENT at Channel Offset 1 and again at Channel Offset 2. 7. Use the up (“NO”). 8. Press ENT and down buttons to turn channel scan on (“Yes”) or off again to save configuration and exit. 9. Base will automatically shut off. Setting/Adjusting Base UID The Lite base’s UID is set before it is shipped and should not be changed. 1. Press the power button 2. Immediately press F1 screen. to turn on the Lite base. while Wireless eSystems scrolls across the base’s 3. Device Address should be displayed. 4. Use the Left change. and Right buttons to select the correct digit you wish to iRespond UltraLite Technical Manual 2 5. Use the up and down buttons to change the number. Adjusting Base Offset The Offset is the center frequency for all remote radios, ensuring base can communicate with all remotes. The Lite base’s Offset is set before it is shipped and should never be changed. 1. Press the power button to turn on the Lite base. 2. Immediately press F1 screen. while Wireless eSystems scrolls across the base’s 3. Device Address should be displayed. 4. Press ENT three times. Base will read Offset 1. 5. Connect spectrum analyzer to base’s antenna connection. 6. Offset #1 is for Lite remotes, Offset #2 is for Touch remotes. Use the Up and Down arrows to adjust offset until the spectrum analyzer shows the base on the center frequency for that offset. 7. Press ENT and complete Steps 5-6 for Offset 2. 8. Press ENT twice when complete. Turn Base on in Programming Mode 1. Press and hold the F1 button. 2. Press and release the power button without letting go of F1 3. When USB Pgm v#.# appears, let go of F1 button. 4. Base will shut off when it has completed programming iRespond UltraLite Technical Manual 3 UltraLite Remote Unit To Login by PIN An iRespond session must be running to login to a remote. 1. Press the power button to turn on the UltraLite remote. 2. Use the A-E Buttons to enter the correct characters of your PIN. 3. If the PIN was entered incorrectly, the right light will blink red once. 4. Renter your PIN. (If you fail to log in again, verify your PIN with the instructor) To Login Anonymously Instructor must have the iRespond session set up to allow anonymous logins. 1. Press the power 2. Press the A press. button to turn on the Lite remote. button four times; ensure left light blinks orange after each 3. If the right led blinks red once, verify Allow Anonymous Logins was checked in Session Setup. To Answer Multiple-Choice Questions 1. Select the appropriate A-E button. iRespond UltraLite Technical Manual 4 FCC Non-modification statement: Changes or modifications not expressly approved by Wireless eSystems Inc. could void the user’s authority to operate this equipment. FCC Non-Modification Statement: This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received. Including interference that may cause undesired operation. iRespond UltraLite Technical Manual 5
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res Page Count : 7 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:52da2f14-acfe-46dc-a9c9-bd91f1d1e3f4 Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2008:07:14 15:50:23-07:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2008:07:14 15:50:52-07:00 Metadata Date : 2008:07:14 15:50:52-07:00 Document ID : uuid:383babe2-009f-4729-9bd8-f125818dd551 Format : application/pdf Title : Microsoft Word - UltraLiteTechManualwcover.doc Creator : daniel Author : danielEXIF Metadata provided by EXIF.tools