Wistron NeWeb BLANKA WNC RFID Smart Reader User Manual

Wistron NeWeb Corporation WNC RFID Smart Reader

User Manual

                RFID Smart Reader with Fan-out Box and RF Switch User Manual English
Table of Contents                        WNC RFID Smart Reader Wistron NeWeb Corporation©                                                  1  1. GETTING STARTED .................................................................................... 2 1.1 IN THE PACKAGE ........................................................................................ 2 1.2 INTRODUCTION .......................................................................................... 2 1.3 HARDWARE OVERVIEW- RFID SMART READER ............................................ 4 1.4 HARDWARE OVERVIEW- FAN-OUT BOX ........................................................ 5 1.5 HARDWARE OVERVIEW - RF SWITCH ........................................................... 5 1.6 CONNECTING THE CABLES .......................................................................... 6 2. CONFIGURATION SOFTWARE ................................................................... 9 2.1 ACCESS THE MANAGEMENT INTERFACE ....................................................... 9 2.2 MANAGEMENT ........................................................................................... 9 3. APPENDIX .................................................................................................. 10 3.1 SPECIFICATIONS: RFID SMART READER .................................................... 10 3.2 SPECIFICATIONS: FAN-OUT BOX ................................................................ 12 3.3 SPECIFICATIONS: RF SWITCH ................................................................... 13 3.4 PIN DEFINITION ....................................................................................... 14
1 Getting Started                                            WNC RFID Smart Reader Wistron NeWeb Corporation©                                                    2  1.  Getting Started 1.1  In the Package     RFID Smart Reader Power Cord Power Adapter       Fan-out Box (optional) RF Switch (optional)     Note: The Fan-out Box and RF Switch work in combination to allow more antenna connections. One RFID Smart Reader can connect to one Fan-out box and four RF switches.      1.2  Introduction The WNC RFID Smart Reader (the Reader) is suitable for a variety of UHF RFID applications. It provides high level RF performance, a user-friendly software development interface and a cost competitive reader solution. Combined with a Newave Shelf Antenna, it can provide 100% readability in zone sizes of 2’x2’x2’ to 10’x10’x10’ with appropriate reader parameters and antenna setup. You can also connect the Reader to a fan-out box and 1~4 RF switches to add additional antennas. A maximum of 16 antennas are allowed for one Reader. For multi-reader applications, such as retail applications, the Reader solution can efficiently compress data size and solve data traffic issues.
1 Getting Started                                            WNC RFID Smart Reader Wistron NeWeb Corporation©                                                    3  Basic application:   You can connect to up to four antennas and use a computer to monitor detected parameters.     Advanced application:   Use the Reader with a Fan-out Box and an RF Switch to connect up to 16 antennas.
1 Getting Started                                            WNC RFID Smart Reader Wistron NeWeb Corporation©                                                    4  1.3  Hardware Overview- RFID Smart Reader  Front Panel  Rear Panel   WAN Connect a standard RJ-45 Ethernet cable to the port to establish a network connection. This feature allows you to configure settings or read the data from the Reader on your computer via a Graphic User Interface. WAN port supports Power over Ethernet (PoE).   LAN Currently unavailable. DC IN Connect the power adapter to the Reader via this inlet to power on the Reader. GPIO For GPIO purposes such as connecting a Fan-out Box, light sensor or other sensors.   Antenna Ports For RF cable insertion. The Reader supports up to four antennas at the same time. Additional connection is also possible via an optional antenna switch. Note: RJ-45 Ethernet cable and RF cable not included in the package.
1 Getting Started                                            WNC RFID Smart Reader Wistron NeWeb Corporation©                                                    5  1.4  Hardware Overview- Fan-out Box   OUTPUT For RF Switch connection.   INPUT Connect to the GPIO port of the Reader. Device 1 & 2   Sensor data input/output ports for other applications, for example, connecting to entrance and exit sensors for security control.  1.5  Hardware Overview - RF Switch  INPUT Connect to an OUTPUT port of the Fan-out Box. RF IN Connect to an antenna port of the Reader.   ANT 1~4   For antenna connection.
1 Getting Started                                            WNC RFID Smart Reader Wistron NeWeb Corporation©                                                    6  1.6  Connecting the Cables  Basic installation:      1. Plug an RF cable into an antenna port and an antenna. The Reader supports up to four antennas at the same time. 2. Connect an RJ-45 Ethernet cable to the WAN port and to your computer for software development interface configuration. 3. Connect the power adapter to the DC IN inlet on the Reader. Once the power adapter is connected to the Reader, the Power LED indicator will turn green indicating the power is on. Note: Reader may be wall-mounted. Insert screws via the four holes on the left and right side of the Reader.
1 Getting Started                                            WNC RFID Smart Reader Wistron NeWeb Corporation©                                                    7  Installation with Fan-out Box and RF Switch:
1 Getting Started                                            WNC RFID Smart Reader Wistron NeWeb Corporation©                                                    8  1.  Use an RF cable to connect an antenna port of the Reader to the RF IN port of the RF Switch, and then connect the antennas to the ANT1~4 ports of the RF Switch. 2.  Use a DB9 cable to connect the GPIO port of the Reader and the INPUT port of the Fan-out box. Note: Only use a rollover type DB9 cable (not crossover type.) The cable must be shorter than 5m.   3.  Use a DB9 cable to connect an OUTPUT port of the Fan-out Box to the INPUT port of the RF Switch. Note: Only use a rollover type DB9 cable shorter than 30m. 4.  Connect the Reader to a computer. Attach the power supply to the Reader and plug it into a wall outlet. 5.  You can also connect the Device1 & 2 ports to receive data from other devices such as sensors.    Note: The Reader, Fan-out Box and the RF Switch may be wall-mounted. Insert screws via the four holes on the left and right side of them.  1.5 LED Status (RFID Smart Reader)  Status   LED                   Green Red Off Power On: Powered on On: Power booting No Power Data Blinking: Data transmitting N/A No transmission Port 1 ~ 4 On: Port enabled Blinking: RF inventory On: Port error Blinking: RF failure Port disabled
2 Software                            WNC RFID Smart Reader Wistron NeWeb Corporation©                                                  9  2.  Configuration Software 2.1  Access the Management Interface 2.2  Management
3 Appendix                                                            WNC RFID Smart Reader Wistron NeWeb Corporation©                                                  10  3.  Appendix 3.1  Specifications: RFID Smart Reader RF System    Chipset Impinj R2000 ATMEL AT91SAM7S-256  Protocol  RFID Protocol Support EPC Global Gen 2 ISO 18000-6C; ISO 18000-6B (optional) Support EPC DRM   Yes (with DRM Filter) switchable  RF  Frequency US: 902 ~ 928MHz EU: 865 ~ 868MHz KR: 910 ~ 914MHz PRC: 920 ~ 925MHz Open: 840MHz ~ 960MHz Demodulation ASK or PSK Modulation Depth 90% nominal Data Encoding FM0 or Miller code Bit Rate Supports uplink data rates of up to 640 Kbps TX Output power 28 dBm  Antenna Type 4 port Mono-static Antenna connector 4 pcs RP TNC  General Characteristics  Dimensions 18.2 x 13 x 2.6 cm Weight ~550g Base Material Aluminum alloy (AL 5052) Mounting Wall, floor Power Input 1. POE 802.3at 2. DC power input (12 VDC +/-5%, 30W) Power Consumption 11W
  3 Appendix                                                        WNC RFID Smart Reader Wistron NeWeb Corporation©                                                    11     System Architecture  Processor TI TMS320DM6446 System Memory / Ram 64MB Internal Storage / Flash 128MB   Communication  USB N/A Ethernet 10/100 Base-T (RJ-45) X2 (POE x 1 802.3 at compliant) GPIO 4 input and 2 output (DB9) Indicators 5 two-color / 1 one-color LED status indicator  Software  Operation System Embedded Linux Software SDK C#   Environment  Humidity 5% to 95%, non-condensing Operating Temperature - 20℃ to 50℃ / -4°F to 122°F   Storage Temperature - 40℃ to 85℃ / -40°F to 185°F Sealing / Dust and Water Immunity IP54 (NEMA 3)
  3 Appendix                                                        WNC RFID Smart Reader Wistron NeWeb Corporation©                                                    12  3.2  Specifications: Fan-out Box      RF System    Chipset MC33202DR2G  Regulatory and Environmental Compliance EMC certification FCC 47 CFG Ch.1 Part 15 (US) (15.247) ETSI EN 302 208-1 (V1.1.1) (EU) (optional) Certification RoHS / FCC / CE(optional)  General Characteristics  Dimensions 12.5 x 6.2 x 2.6 cm Weight ~250g Base Material Aluminum alloy (AL 5052) Mounting Wall, floor Power Consumption 0.5W   Communication  Input port 1 DB9 female connector Output port 4 DB9 female connector External port 2 ACES product:2.0mm WTB WAFER CONN   Environment  Humidity 5% to 95%, non-condensing Operating Temperature - 20℃ to 50℃ / -4°F to 122°F   Storage Temperature - 40℃ to 85℃ / -40°F to 185°F Sealing / Dust and Water Immunity IP54 (NEMA 3)
  3 Appendix                                                        WNC RFID Smart Reader Wistron NeWeb Corporation©                                                    13  3.3  Specifications: RF Switch     RF System    Chipset SN74HC139PWR SN74HC240PWR AS221  RF Frequency US: 902 ~ 928MHz/ EU: 865 ~ 868MHz/ KR: 910 ~ 914MHz/ PRC: 920 ~ 925MHz/ Open:840MHz ~ 960MHz/ Typical Insertion Loss 1.2dB   Typical Isolation 36dB   Regulatory and Environmental Compliance EMC certification FCC 47 CFG Ch.1 Part 15 (US) (15.247) ETSI EN 302 208-1 (V1.1.1) (EU) (optional) Certification RoHS / FCC / CE(optional)  General Characteristics  Dimensions 11.4X5.8X2.6 cm Weight ~350g Base Material Aluminum alloy (AL 5052) Mounting Wall, floor   Communication  Input port 1 DB9 female connector R-TNC 4 R-TNC Connector   Environment  Humidity 5% to 95%, non-condensing Operating Temperature - 20℃  to 50℃ / -4°F to 122°F   Storage Temperature - 40℃  to 85℃ / -40°F to 185°F Sealing / Dust and   Water Immunity IP54 (NEMA 3)
  3 Appendix                                                        WNC RFID Smart Reader Wistron NeWeb Corporation©                                                    14  3.4  Pin Definition      GPIO port of RFID Smart Reader   DB9 Female connector   Pin1   5V   Pin2   Output port1, 3.2V   Pin3   Output port3, 3.2V   Pin4   Input port1, 3.2V   Pin5   Ground   Pin6   Ground   Pin7   Output port2, 3.2V   Pin8   Output port4, 3.2V   Pin9   Input port2, 3.2V     Output ports of Fan-out Box Output Port Pin1   5V   Pin2   GPO_1-   Pin3   NC   Pin4   GPO_2+   Pin5   Ground   Pin6   Ground   Pin7   GPO_1+   Pin8   GPO_2-   Pin9   NC
  3 Appendix                                                        WNC RFID Smart Reader Wistron NeWeb Corporation©                                                    15    Device 1&2 ports of Fan-out Box Device 1   Pin1   5V   Pin2   GPI_1   Pin3   GPO_3   Pin4   Ground   Device 2   Pin1   5V   Pin2   GPI_2   Pin3   GPO_4   Pin4   Ground
Federal Communication Commission Interference Statement  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:  -  Reorient or relocate the receiving antenna. -  Increase the separation between the equipment and receiver. -  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -  Consult the dealer or an experienced radio/TV technician for help.  FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.  This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
 台灣使用注意事項: 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。   低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電通信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾