Wistron NeWeb LMLORA UMC-LORA User Manual 1

Wistron NeWeb Corporation UMC-LORA 1

User Manual

   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 1 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document          UMC-LORA User Manual                   The document contains proprietary information which is the property of Wistron NeWeb Corporation and is strictly confidential and shall not be disclosed to others in whole or in part, reproduced, copied, or used as basic for design, manufacturing or sale of apparatus without the written permission of Wistron NeWeb Corporation.
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 2 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document Revision History Issue Date Version Description 2017/08/31 1.0 Initial Issued 2017/10/24 2.0 Updated according to reviewer 2017/10/31 3.0 Update OEM installation statement
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 3 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document Contents 1. Introduction .......................................................................................................................................... 4 2. Test Setup Configuration ..................................................................................................................... 6 2.1 Power Supply and Debug Console Connection ...................................................................... 6 2.2 RF Connection ........................................................................................................................... 9 2.3 Hardware Component Introduction ..................................................................................... 10 3. Installation and Test Method ..............................................................................................................11 3.1 Attach UMC-LORA card onto SMCC........................................................................................11 3.2 Install GDM7243 Driver ......................................................................................................... 13 3.3 Confirm the GDM7243 device ............................................................................................... 13 3.4 Open the com port by PuTTy ................................................................................................. 14 3.5 Lora Test Command ............................................................................................................... 16 4. Test Equipment ................................................................................................................................... 17 5. Antenna performance ........................................................................................................................ 17
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 4 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document 1.    Introduction This User Manual of ISM module is to describe how to use the following sections for lab test by specific qualified engineers or technicians.  Furthermore, this module is NOT intended for commercial use but designed as part of Smart Meter product which mainly provides ISM-900 access capabilities. For the procedure of SMCC installation into electric meter  and  the operation  of  SMCC in  assembly factory, that  information is  described  in assembly instruction document.  FCC ID Location FCC ID is placed in manual instead of label area, for the reason that the device is too small  to  have  FCC  ID  been  properly  placed  on  label  area,  because  of  over  crowded identification of other product and regulatory information.    Model : UMC-LORA P/N: 81.UMCLORA.G01 FCC ID: NKR-LMLORA FCC Interference Statement This  module  complies  with  Part  15  of  the  FCC  Rules.  Operation  is  subject  to  the following two conditions: (1) This module may not cause harmful interference and (2) this module  must  accept  any  interference  received,  including  interference  that  may  cause undesired operation. FCC Statement for a Class B digital device or peripheral,   This equipment has been tested and found to comply with the limits for a Class B digital device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide reasonable  protection  against  harmful  interference  in  a  residential  installation.  This equipment  generates, uses and can radiate radio frequency energy and, if not installed and  used  in  accordance with  the  instructions,  may  cause  harmful  interference to  radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 5 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document television reception, which can be determined by turning the equipment off and on, the user  is  encouraged  to  try  to  correct  the  interference  by  one  or  more  of  the  following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to  which  the receiver is connected. —Consult the dealer or an experienced radio/ TV technician for help. Radiation Exposure Statement This module complies with FCC radiation exposure limits set forth for an uncontrolled environment.  This  module  should  be  installed  and  operated with  minimum  distance of 20cm between radiator and human body.  Any  changes  or  modifications  not  expressly  approved  by  the  party  responsible  for compliance could void the user’s authority to operate the device.
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 6 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document 2.       Test Setup Configuration 2.1 Power Supply and Debug Console Connection  10 pin Connect to interface board Don’t care last 2 pin CB Interface Board
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 7 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document      AC-DC 5V Adaptor Interface Board   CB USB Debug Port Console UMC-LORA (DUT)
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 8 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document Power on Sequence: I. Connect DUT to interface board II. Attach AC-DC Adaptor & USB Debug Port Cable III. Wait for 20 seconds when system ready
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 9 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document 2.2 RF Connection  Connection for LORA internal antenna  Connection for conducted test
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 10 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document 2.3 Hardware Component Introduction LORA card (DUT)  AC/DC Adaptor  SMCC  Interface Board
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 11 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document 3. Installation and Test Method 3.1 Attach UMC-LORA card onto SMCC Step 1 : Connect the board to board connector To invert Lora card and combine the female & male connector.  Step 2 : Fix the Lora card To invert SMCC and screw 3 screws at indicated points on SMCC with Lora card. The black screw is corresponding to the SMT nut and the silver screws are corresponding to the holder bosses.
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 12 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document OEM installation statement: This device is intended only for OEM integrators under the following conditions: 1)    The antenna must be installed such that 20 cm is maintained between the antenna and users. For laptop installations, the antenna must be installed to ensure that the proper spacing is maintained in the event the users places the device in their lap during use (i.e. positioning of antennas must be placed in the upper portion of the LCD panel only to ensure 20 cm will be maintained if the user places the device in their lap for use) and 2)    The transmitter module may not be co-located with any other transmitter or antenna.    As long as the 2 conditions above are met, further transmitter testing will not be required.    However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed (for example, digital device emissions, PC peripheral requirements, etc.). IMPORTANT NOTE:    In the event that these conditions cannot be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID cannot be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. End Product Labeling: This transmitter module is authorized only for use in devices where the antenna may be installed such that 20 cm may be maintained between the antenna and users (for example access points, routers, wireless ASDL modems, certain laptop configurations, and similar equipment). The final end product must be labeled in a visible area with the following: "Contains TX FCC ID: {INSERT FCC ID HERE}".     RF Exposure Manual Information That Must be Included: The users manual for end users must include the following information in a prominent location "IMPORTANT NOTE: To comply with FCC RF exposure compliance requirements, the antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter." Additional Information That Must be Provided to OEM Integrators: The end user should NOT be provided any instructions on how to remove or install the device.
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 13 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document 3.2 Install GDM7243 Driver Install the GDM7243 driver “GDM7243_windows_acm_drivers_installer_v1.1.0.0.zip”  3.3 Confirm the GDM7243 device    Confirm the com port “Remote NDIS based Internet Sharing Device ” in the Device Manager.
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 14 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document 3.4 Open the com port by PuTTy Install PuTTy for connection to DUT, refer to http://www.putty.org/ Host Name: 192.168.0.1 ; Port: 35001 ; Connection Type: SSH
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 15 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document  1. Login as: diags   2. Find the one time password(OTP) with prompt number 3. Ex: 9998: IDLE EYED MATE MID MAGI DIRT 4. Enter command: echo stop-zigbee|cli   5. Enter command: echo stop-system|cli  OTP List: 9998: IDLE EYED MATE MID MAGI DIRT 9997: ACRE BULK MILE BOLO WAYS WOVE 9996: CHOU PAW OATH KANE ORE TERN 9995: NAG JIVE OS MUM LION HOBO 9994: SON DEAN MONK MAW LUCY ACRE 9993: BLUE FLAT LAWN HID TEET BOCK 9992: SOLD KIRK BOSS LULU INK ROOK 9991: SHOE OUST CASH ALAN ROSE LUSH 9990: CUBA HOLD HERB JUJU FUSS GAUL 9989: RITE FLAT TOOL HUM SEEK OS 9988: DOWN MITT FISK CAGE GEL MUCH 9987: HIGH DRY TORN LOY LUSH FROM 9986: SNOW FAWN LAME MURK BED EAT
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 16 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document 3.5 Lora Test Command
   Subject: UMC-LORA User Manual                                                                      REV: 2.0                                                                                        PAGE 17 OF 17  Wistron Neweb Corporation Proprietary & Confidential      Design Document 4. Test Equipment It is suggested to use Anritsu MT2830C for RF conductive tests.setc  5. Antenna performance   For ISM radiation tests, the ISM antenna gain shows in below table.  Frequency(MHz) Average Gain(dB) Peak Gain(dB) Efficiency(%) 902 -5.16 1.03 30% 905 -5.18 0.97 30% 910 -5.09 0.84 31% 915 -5.18 0.73 30% 920 -5.19 0.7 30% 925 -5.28 0.58 30% 928 -5.25 0.57 30%

Navigation menu