Wistron NeWeb SWA51 Wireless Audio Module User Manual

Wistron NeWeb Corporation Wireless Audio Module

User Manual

Download: Wistron NeWeb SWA51 Wireless Audio Module User Manual
Mirror Download [FCC.gov]Wistron NeWeb SWA51 Wireless Audio Module User Manual
Document ID4038610
Application IDlwly2wov6j2YNNv5g6O9aw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize16.62kB (207721 bits)
Date Submitted2018-10-17 00:00:00
Date Available2018-10-19 00:00:00
Creation Date2018-10-16 17:15:17
Producing SoftwareAcrobat Distiller 15.0 (Windows)
Document Lastmod2018-10-16 17:54:31
Document TitleMicrosoft Word - SWA51 Module Datasheet FOR Regulation_0918 手冊 ok
Document CreatorPScript5.dll Version 5.2.2
Document Author: EmilyChen

SWA51, 5GHz Module Datasheet
Extended Range Mono/Stereo Wireless Audio System, based on the Avnera AV5100 IC
General Description
Features
The SWA51 module is a member of a family of
products representing a new level of system
integration offering customers fast time to
market with a point-to-point mono, or stereo,
wireless connection. These modules are
optimized for low-cost, high-quality and ease-ofuse.

The module incorporates Avnera’s proprietary
5GHz wireless audio protocol, designed from the
ground up specifically for audio. It features low
fixed latency, uncompressed CD quality mono or
stereo audio, superior interference immunity,
and inherent coexistence with WiFi.
Audio Interfaces


I2S Digital Input / Output interface with
>93dB end-to-end digital audio path
Wireless Range (Typ)

> 50m Non Line Of Sight (NLOS) range

> 160m Line Of Sight (LOS) range

Frequency range: 5.15-5.25&5.725-5.825 GHz,
continuous dynamic channel selection

Forward error correction coding, error
detection, and audio-specific error
concealment

Dual printed PCB diversity antennas for
multipath and fading mitigation

Auto-search/synch and dynamic channel
selection

Low, fixed latency

24 pin FPC or pin header connector
The module measures 26 x 47 x 3.3 mm and is
provided with a 24 pin FPC connector.

Sample rate converter: Support for 32 - 96kHz
input sample rates
The module is certified to FCC and CE
standards.

Customizable firmware for simple, low-cost,
sub-woofer amplifier implementations

RF parts can-shielded, module meets FCC
part 15 rules for emissions and susceptibility.

General purpose over-the-air (OTA) serial
interface:
The SWA51 module integrates all features
necessary to complete a wireless stereo or
mono link, including AV5100 Wireless Audio
Chip, printed diversity antennas, PA, shield can,
flash memory, interface connector and all
passive components. Just provide power and an
I2S interface and you are ready to create a
wireless audio link.
Applications




Wireless Subwoofers
Stereo Wireless Rear Speakers
Soundbar / Audio Video Receiver / BluRay
Mono/Stereo Audio Channel Transmission

11 kbps, bi-directional, full duplex

Support for amplifier control data, metadata, and remote control commands
Ordering Options
SWA51 TX: Transmit module with digital audio
input
SWA51 RX: Receive module with digital audio
output
Different labels and P/Ns are used to
distinguish between TX and RX.
CONFIDENTIAL | PROVIDED UNDER NDA
SWA51 Module Datasheet
Rev 1.1
Functional Description
The SWA51 module is available in 2 variations; digital input transmitter module or digital output receiver
module.
There are three available I2S digital audio data inputs/outputs, each of these can be configured to operate as
either a master or a slave - depending on the application, the I2S ports can operate simultaneously as either
inputs or outputs. When configured as slaves, the I2S inputs/outputs can be independently clocked by up to
two external masters. In addition, MCLK can be output from the module to provide a reference clock source to
an external ADC or DAC. MCLK can also be input to the module to provide a reference clock from an
external source.
The hardware for the audio input (transmit) and audio output (receive) versions of the module is identical and
only the firmware loaded onto the module determines its function.
The highly integrated nature of the AV5100 transceiver IC results in few external components being required
for the SWA51 module design. 2 printed PCB antennas are used to achieve increased range, and to achieve
antenna spatial diversity. The extended-range RF path consists of the antennas, associated tuning
components, shield can, the RF switch, and two baluns, one connected to each of the RF input/output ports
on the AV5100 IC.
A 16MHz crystal oscillator generates the AV5100 fundamental system clock used as the basis for all RF and
digital audio clocks.
A 2Mb flash memory chip is used to store the module’s application firmware. The AV5100 is able to boot from
internal ROM upon first power up, which enables programming the flash chip with the application firmware . In
addition, Over-the-air Firmware upgrade capability can be enabled through the application firmware. The
module can be controlled from an external host device via the I2C Slave or the SPI Slave data interfaces. The
I2C master port allows the module to control other system audio devices such as a sub-woofer amplifier
system without having to add another MCU to the product design. Up to 9 additional GPIOs are available on
the SWA51 module (not including I2C and I2S signals) for implementing different UI features on the target
application. The resources mentioned above can be leveraged to implement low cost sub-woofer designs as
outlined below.
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
CONFIDENTIAL
SWA51 Module Datasheet
1.1
Rev 1.1
SWA51 Module Connections and Interfaces
Signal Type
Description
+3.3V Supply
The SWA51 hardware is configured to accept a nominal +3.3V supply.
Reset
Active low reset input. This pin is driven from an open collector/drain device such
that it can be pulled to ground for the active reset state but, when released, must
go to a high impedance state. This pin should not be actively driven high, as the
AV5100 internal reset circuit will not operate correctly.
I2S In Port
The I2S input port can be configured as a master or slave. Consequently BCLK
and LRCK can be either inputs or outputs. In addition, MCLK can be sourced by
the module on pin 16. Since the AV5100 IC contains a sample rate converter,
MCLK is not required to be supplied to the module when it is an I2S slave.
CMOS 3.3V logic levels are used for all I2S signals.
I2S Out Port
The I2S output port can be configured as a master or slave. Consequently BCLK
and LRCK can be either inputs or outputs. In addition, MCLK can be sourced by
the module on pin 16. Since the AV5100 IC contains a sample rate converter,
MCLK is not required to be supplied to the module when it is an I2S slave.
CMOS 3.3V logic levels are used for all I2S signals.
I2C Slave Port
The I2C slave port can be used for external host communication and for module
testing. It is assumed that external pull up resistors are connected at the I2C
master communicating with the module.
I2C Master Port
The I2C master port is used to communicate with external audio devices such as
a sub-woofer amplifier. It is assumed that external pull up resistors are included
on the application board.
GPIOs
3.3V CMOS logic level GPIOs available to connect to other devices, or to use as
UI supporting GPIOs for LED and button support. All supported GPIOs can be
configured as outputs or inputs with configurable pull-ups/pull-downs.
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
CONFIDENTIAL
SWA51 Module Datasheet
Rev 1.1
2 SWA51 Connector Information
Table 1: SWA51 Connector Information
No
Pin Name
Pin
Type
AV5100 Pin
SWA51-TX Pin
Description
SWA51-RX Pin
Description
GPIO2/S_SSB
Digital
I/O
12
GPIO or SPI
Slave Chip
Select
GPIO or SPI
Slave Chip
Select
GPIO3/S_SCLK
Digital
I/O
11
GPIO or SPI
Slave Serial
Clock
GPIO or SPI
Slave Serial
Clock
GPIO4/S_SDA/S_MOSI
Digital
I/O
10
GPIO, I2C
Slave Serial
Data or SPI
Slave Data In
GPIO, I2C
Slave Serial
Data or SPI
Slave Data In
GPIO5/S_SCL/S_MISO
Digital
I/O
GPIO, I2C
Slave Serial
Clock or SPI
Slave Data Out
GPIO, I2C
Slave Serial
Clock or SPI
Slave Data Out
GPIO16/M_SDA
Digital
I/O
GPIO, I2C
Master Serial
Data
GPIO, I2C
Master Serial
Data
GPIO17/M_SCL
Digital
I/O
GPIO, I2C
Master Serial
Clock
GPIO, I2C
Master Serial
Clock
GPIO20/LINK_LED
Digital
I/O
56
GPIO, or
LINK_LED
Output
GPIO, or
LINK_LED
Output
GPIO21/PAIR
Digital
I/O
55
GPIO, or input
from PAIR
Button
GPIO, or input
from PAIR
Button
GPIO18/BCLK1
Digital
I/O
GPIO or I2S
Port 1 Bit Clock
GPIO or I2S
Port 1 Bit Clock
10
GPIO19/WCLK1
Digital
I/O
GPIO or I2S
Port 1 Word
Clock
GPIO or I2S
Port 1 Word
Clock
11
GPIO10/MCLK
Digital
I/O
53
GPIO or Master
Clock Out
GPIO or Master
Clock Out
12
GND
GND
Paddle (57)
GND
GND
13
GPIO11/BCLK0
Digital
I/O
52
GPIO or I2S
Port 0 Bit Clock
GPIO or I2S
Port 0 Bit Clock
14
GPIO12/WCLK0
Digital
I/O
51
GPIO or I2S
Port 0 Word
Clock
GPIO or I2S
Port 0 Word
Clock
15
GPIO13/ADAT0
Digital
I/O
50
GPIO or I2S
Port 0 Audio
Data
GPIO or I2S
Port 0 Audio
Data
16
GPIO14/ADAT1
Digital
I/O
49
GPIO or I2S
Port 1 Audio
Data
GPIO or I2S
Port 1 Audio
Data
17
GPIO15/ADAT2/CEN
Digital
I/O or
Digital
Input
48 or 38
GPIO, I2S Port
2 Audio Data or
(1)
chip enable
GPIO, I2S Port
2 Audio Data or
(1)
chip enable
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
CONFIDENTIAL
SWA51 Module Datasheet
Rev 1.1
18
GPIO22/D+
Digital
I/O
47 or 43
GPIO or USB
Data Plus (2
GPIO or USB
(2)
Data Plus
19
GPIO23/D-
Digital
I/O
46 or 42
GPIO or USB
Data Minus (2
GPIO or USB
(2)
Data Minus
20
GPIO24
Digital
I/O
41
GPIO
21
RESETN_EXT
Digital
Input
37
RESET signal
active low (4
RESET signal
active low (4
22
GND
GND
Paddle (57)
GND
GND
23
VDD
Supply
Input
31, 45, 54
+3.3V input
supply voltage
+3.3V input
supply voltage
24
VDD
Supply
Input
31, 45, 54
+3.3V input
supply voltage
+3.3V input
supply voltage
(3)
GPIO
(3)
Notes:
(1) Pin 17 is hardware configured as GPIO15/ADAT2 by default; utilizing this pin as a CEN requires a
different stuffing option.
(2) Utilizing pins 18 and 19 as USB D+ and D- requires the firmware to Tri-state GPIOs 22 and 23.
(3) Pin 20 (GPIO24) can be utilized to implement a “Data Waiting” interrupt signal for I2C and SPI Slave
data communication.
(4) Pin 21 (RESET_EXT) can be pulled to GND with a switch or an open drain/collector type device to
provide a hard reset signal to the AV5100. This pin is pulled up to VDDIO (3.3V) internally in the
AV5100 and should not be actively driven high.
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
CONFIDENTIAL
SWA51 Module Datasheet
Rev 1.1
3 Electrical, Audio and Timing Specifications
Absolute Maximum Ratings
3.1
Absolute Maximum Ratings (AMR) are stress ratings only. AMR corresponds to the maximum value that can be applied without leading to
instantaneous or very short-term unrecoverable hard failure (destructive breakdown). Stresses beyond those listed under AMR may
cause permanent damage to the device.
Functional operation of the device at these or any other conditions beyond those indicated under “Recommended Operating Range” is
not implied. Exposure to absolute-maximum-rated conditions for extended periods may adversely affect device reliability.
Device functional operating limits and guaranteed performance specifications are given under Electrical Characteristics at the test
conditions specified.
CONDITION
MIN
MAX
+3.3V Supply Voltage Input
-0.3V
4.0V
Input Voltage Range – Digital
Inputs
-0.3V
3.6V
Input Voltage Range – Analog
Inputs
-0.3V
3.6V
Operating Temperature
-40ºC
+60ºC
-40ºC
+70ºC
2kV
----
Storage Temperature
Static Discharge Voltage
Notes:
1) HBM = ESD Human Body Model; C = 100pF, R = 1kΩ
3.2
Recommended Operating Range
PARAMETER
VDD, +3.3V Supply pin voltage
MIN
TYP
MAX
UNIT
3.0
3.3
3.6
55
ºC
Ambient Temperature (TA)
RESET pin hold time
10
Power Supply Rise Time (to 3.0V)
3.3
msec
10
msec
Electrical Characteristics – DC Characteristics
Operating Conditions: VDD = 3.3V, TA = 0°C to +55 °C, RF Freq = 5150‐5250;5725‐5825MHz, measured relative to the RF balun
single‐ended I/O. Typical specifications at TA = 25°C, VDD = 3.3V
PARAMETER
CONDITIONS
Supply Current (IVDDA)
Shutdown (chip disabled)
MIN
Standby (also USB suspend)
RX mode (continuous RX)
Link mode ( for SWA51 TX)
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
TYP
MAX
UNIT
TBD
uA
TBD
2.5
mA
89
mA
110*a
mA
CONFIDENTIAL
SWA51 Module Datasheet
Rev 1.1
Link mode ( for SWA51 RX)
TX mode (continuous TX); Pout=+6dBm
70*a
mA
150*a
mA
CMOS I/O Logic Levels – 3.3V I/O
0.6
Input Voltage Logic Low, VIL
VDDIO
Input Voltage Logic High, VIH
‐0.6
Output Voltage Logic Low, VOL
0.3
VDDIO
‐0.3
Output Voltage Logic High, VOH
*a : This is DCRMS current consumption value. If customer want to implement OCP(over current protection) for SWA51,
please consult with WNC for proper setting and design.
3.4
Electrical Characteristics – RF PLL Characteristics
Operating Conditions: VDD =3.3V, TA = 0°C to +55 °C, RF Freq = 5150‐5250;5725‐5825MHz, measured relative to the RF balun
single‐ended I/O. Typical specifications at TA = 25°C, VDD = 3.3V
PARAMETER
CONDITIONS
MIN
MAX
UNIT
RF Channel Frequency Range
Band1(lower band)
5150
5250
MHz
Band4(Upper band)
5725
5825
MHz
RF Channel frequency resolution (raster)
TYP
MHz
RF I/O Impedance
ANT0,ANT1
50
ohm
Crystal Oscillator Frequency
External crystal
16
Crystal Accuracy Requirement
External XTAL, -20°C to +70 °C
3.5
MHz
+/-20
ppm
Electrical Characteristics – RF RX Characteristics
Operating Conditions: VDD = 3.3V, TA = 0°C to +55 °C, RF Freq = 5150‐5250;5725‐5825MHz, measured relative to the RF balun
single‐ended I/O. Typical specifications at TA = 25°C, VDD = 3.3V
PARAMETER
CONDITIONS
MIN
RF Channel Frequency Range
Band1(lower band)
5150
Band4(Upper band)
5725
RF I/O Impedance
TYP
MAX
UNIT
5250
MHz
5825
MHz
ANT0,ANT1
50
ohm
RX Sensitivity
SSC (single sub-carrier)
-89 *b
dBm
Max input signal
LNA = low gain mode, min IF gain
-5
dBm
Out-of-band blocker level
<5150 MHz, >5850 MHz
2400-2483.5 MHz
-45
-20
dBm
dBm
Spurious RF outputs
5150-5850 MHz
<5150 MHz
>5850 MHz
-55
-63
-63
dBm
dBm
dBm
*b : The sensitivity been defined with BER <= 0.002.
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
CONFIDENTIAL
SWA51 Module Datasheet
Rev 1.1
Electrical Characteristics – RF TX Characteristics
3.6
Operating Conditions: VDD = 3.3V, TA = 0°C to +55 °C, RF Freq = 5150‐5250;5725‐5825MHz, measured relative to the RF balun
single‐ended I/O. Typical specifications at TA = 25°C, VDD = 3.3V
PARAMETER
CONDITIONS
MIN
RF Channel Frequency Range
Band1(lower band)
5150
Band4(Upper band)
5725
TYP
MAX
UNIT
5250
MHz
5825
MHz
RF I/O Impedance
ANT0,ANT1
50
ohm
TX Output power(5150-5250MHz)
SSB&DSB (single side band & double
side band)
dBm
TX Output power(5725-5825MHz)
SSB&DSB (single side band & double
side band)
dBm
-20
dBc
LO leakage
(1) Measured at the worst performing frequency
Electrical Characteristics – Audio C/CS
3.7
PARAMETER
Frequency Response (-3dB)
CONDITIONS
MIN
16 bit audio, 11KSps over-the-air
sample rate
MAX
UNIT
20
5K
Hz
16 bit audio, 14.8KSps over-theair sample rate
20
6.5K
Hz
16 bit audio, 22KSps over-the-air
sample rate
20
10K
Hz
16 bit audio, 29.6KSps over-theair sample rate
20
13K
Hz
16 bit audio, 44KSps over-the-air
sample rate
20
20K
Hz
Gain Flatness1
0dB Input / Output Gain
SNR
I2S Input / Output
THD+N
TYP
±0.2
93 (1)
dB
dB
94
dB
Notes
1-
16-bit audio, all OTA sample rates. OTA 12-bit path for voice is possible, but will limit the SNR to 72dB.
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
CONFIDENTIAL
SWA51 Module Datasheet
3.8
Rev 1.1
AV5100 Rate Converter Characteristics
SRC Block
SRC 0
(Audio)
Input Rates
I2S
32-96K
USB
8k – 48K,
ECU (TX)
“11K”
“14.8k”
“22k”
“29.6k”
“44k”
SRC 1
(LFE)
I2S
32-96K
USB
8k – 48K,
ECU (TX)
“11K”
“14.8k”
“22k”
“29.6k”
“44k”
SRC 2
(Voice)
I2S
32-96K
USB
8k – 48K,
ECU (TX)
“14.8k”
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
Output Rates
SNR (dB)
SRC BW (-3dB)
I2S
Master: 48k
Slave: 44.1K-96K
All rates support
16bit, >93dB
Actual bandwidth is
dependent on the lower
of the input or output
rates.
ECU (TX)
“11K”
“14.8k”
“22k”
“29.6k”
“44k”
Output BW vs OTA
“11k” = 5kHz
“14.8k” = 6.5kHz
“22k” = 10kHz
“29.6k” = 13kHz
“44k” = 20kHz
I2S
Master: 48k
Slave: 44.1K-96K
All rates support
16bit, >93dB
ECU (TX)
“11K”
“14.8k”
“22k”
“29.6k”
“44k”
Actual bandwidth is
dependent on the lower
of the input or output
rates.
Output BW vs OTA
“11k” = 5kHz
“14.8k” = 6.5kHz
“22k” = 10kHz
“29.6k” = 13kHz
“44k” = 20kHz
I2S
Master: 48k
Slave: 44.1K-96K
USB
8k – 48K,
All rates support
16bit, >93dB, but the
OTA 12bit path will limit
SNR to 72dB
Actual bandwidth is
dependent on the lower
of the input or output
rates.
Output BW vs OTA
“11k” = 5kHz
“14.8k” = 6.5kHz
“22k” = 10kHz
“29.6k” = 13kHz
“44k” = 20kHz
ECU (RX)
“14.8k”
CONFIDENTIAL
SWA51 Module Datasheet
3.9
Rev 1.1
I2S Communication Interface Timing
Table 2: SWA51 I2S Timing
VL
VH
TLo
THi
low voltage level
high voltage level
clock period
clock low period
clock high period
TR
TF
TSu
THd
TOd
rise time
fall time
setup time
hold time
output delay
bit clocks/word clock
MIN
-0.3V
2.4V
TYP
0.0V
3.3V
325.5n
0.4T
0.4T
MAX
0.4V
3.6V
UNIT
NOTES
Note 1
Note 1
1/3.072MHz
0.6T
0.6T
50n
50n
25n
25n
-25n
25n
64
I2S protocol is “I2S Justified” as shown below.
Note 1: The timing specified for the rise and fall times represents the edge rates on the module itself. The rise
and fall times of the I2S signals are determined by ESD/EMI mitigation components on the modules, as well
as external loading, and will be higher than the specified numbers
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
10
CONFIDENTIAL
SWA51 Module Datasheet
Rev 1.1
3.10 I2C Master/Slave Communication Interface Timing (S_SCL, S_SDA)
The SWA51 has both I2C slave and master interfaces available with their respective pins S_SCL, S_SDA and
M_SCL, M_SDA. The interfaces operate in I2C fast-mode and can receive and transmit at up to 400 kbit/s.
Bytes are 8 bits long and are transferred with the most significant bit (MSB) first. Each byte has to be followed
by an acknowledge bit. The SWA51 will apply clock-stopping (by holding the clock line S_SCL LOW to force
the master into a wait state) if necessary due to internal high-priority tasks.
The slave/master interface can be used both for writing (e.g. sending commands) or reading (e.g. requesting
status). An additional GPIO pin on the SWA51 (Ex. GPIO24), can be used to notify the I2C master when a
pending message is ready to be sent.
The SWA51 slave interface responds to the 7-bit slave address 1000000 (0x40) as shown in Figure 1 below.
Figure 5: First Byte after the START Procedure
ELECTRICAL SPECIFICATIONS AND TIMING
Table 3: Characteristics of the S_SDA and S_SCL I/Os
PARAMETER
SYMBOL
LOW level input voltage
HIGH level input voltage
LOW level output voltage (open drain or
open collector) at 1 mA sink current:
Output fall time from VIHmin to VILmax with
a bus capacitance from 10 pF to 400 pF
Pulse width of spikes which must be
suppressed by the input filter
S_SCL clock frequency
LOW period of the S_SCL clock
HIGH period of the S_SCL clock
Data hold time
Data set-up time
VIL
VIH
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
FAST-MODE
MIN.
MAX.
0.8
0.3
2.0
3.6
UNIT
VOL
0.4
tof
250
ns
tSP
50
ns
1.3
0.6
100
400
kHz
s
s
ns
ns
fSCL
tLOW
tHIGH
tHD;DAT
tSU;DAT
11
100
–
–
–
–
CONFIDENTIAL
SWA51 Module Datasheet
Rev 1.1
Figure 6: Definition of Timing for F/S-Mode Devices on the I2C-Bus
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
12
CONFIDENTIAL
SWA51 Module Datasheet
Rev 1.1
Ordering Information
Table 4: SWA51 Module Ordering Information
Module Part
Number
SWA51
Option
Code
TX
SWA51
RX
Description
Digital Input , FPC Connector, integrated printed PCB
antennas
Digital Output, FPC Connector, integrated printed PCB
antennas
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
13
CONFIDENTIAL
SWA51 Module Datasheet
Rev 1.1
FCC Statement:
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
● Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This device and its antenna(s) must not be co-located with any other transmitters except in
accordance with FCC multi-transmitter product procedures.
Refering to the multi-transmitter policy, multiple-transmitter(s) and module(s) can be operated
simultaneously without C2P.
This device is restricted for indoor use
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
14
CONFIDENTIAL
SWA51 Module Datasheet
Rev 1.1
IMPORTANT NOTE:
This module is intended for OEM integrator. The OEM integrator is responsible for the compliance to all the
rules that apply to the product into which this certified RF module is integrated.
Additional testing and certification may be necessary when multiple modules are used.
20 cm minimum distance has to be able to be maintained between the antenna and the users for the host this
module is integrated into. Under such configuration, the FCC radiation exposure limits set forth for an
population/uncontrolled environment can be satisfied.
Any changes or modifications not expressly approved by the manufacturer could void the user's authority to
operate this equipment.
USERS MANUAL OF THE END PRODUCT:
In the users manual of the end product, the end user has to be informed to keep at least 20 cm separation
with the antenna while this end product is installed and operated. The end user has to be informed that the
FCC radio-frequency exposure guidelines for an uncontrolled environment can be satisfied. The end user has
to also be informed that any changes or modifications not expressly approved by the manufacturer could void
the user's authority to operate this equipment. If the size of the end product is smaller than 8x10cm, then
additional FCC part 15.19 statement is required to be available in the users manual: This device complies with
Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause
harmful interference and (2) this device must accept any interference received, including interference that
may cause undesired operation.
LABEL OF THE END PRODUCT:
The final end product must be labeled in a visible area with the following " Contains TX FCC ID: NKR-SWA51
". This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Responsible Party:
Contact name : Ted Su
Company : W-NeWeb Corporation
Address: 1525 McCarthy Blvd, Suite 206, Milpitas, CA 95035, U.S.A.
Tel: +1-408-457-6823
Fax: +1-408-457-6789
E-mail : Ted.Su@wnc.com.tw
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
15
CONFIDENTIAL
SWA51 Module Datasheet
Rev 1.1
IC Statement:
The device for operation in the band 5150–5250 MHz is only for indoor use to reduce the potential for harmful
interference to co-channel mobile satellite systems.
les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une
utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de
satellites mobiles utilisant les mêmes canaux.
For indoor use only.
Pour une utilisation en intérieur uniquement.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit
pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
This device and its antenna(s) must not be co-located with any other transmitters except in
accordance with IC multi-transmitter product procedures.
Refering to the multi-transmitter policy, multiple-transmitter(s) and module(s) can be operated
simultaneously without reassessment permissive change.
Cet appareil et son antenne (s) ne doit pas être co-localisés ou fonctionnement en association avec une autre
antenne ou transmetteur.
IMPORTANT NOTE:
IC Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20 cm between the radiator & your
body.
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un
environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20cm
de distance entre la source de rayonnement et votre corps.
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
16
CONFIDENTIAL
SWA51 Module Datasheet
Rev 1.1
IMPORTANT NOTE:
This module is intended for OEM integrator. The OEM integrator is responsible for the compliance to all the
rules that apply to the product into which this certified RF module is integrated.
Additional testing and certification may be necessary when multiple modules are used.
20 cm minimum distance has to be able to be maintained between the antenna and the users for the host this
module is integrated into. Under such configuration, the IC RSS-102 radiation exposure limits set forth for an
population/uncontrolled environment can be satisfied.
Any changes or modifications not expressly approved by the manufacturer could void the user's authority to
operate this equipment.
USERS MANUAL OF THE END PRODUCT:
In the users manual of the end product, the end user has to be informed to keep at least 20 cm separation
with the antenna while this end product is installed and operated. The end user has to be informed that the IC
radio-frequency exposure guidelines for an uncontrolled environment can be satisfied. The end user has to
also be informed that any changes or modifications not expressly approved by the manufacturer could void
the user's authority to operate this equipment. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference and (2) this device must accept any interference received,
including interference that may cause undesired operation.
LABEL OF THE END PRODUCT:
The final end product must be labeled in a visible area with the following " Contains IC: 4441A-SWA51 ".
The Host Model Number (HMN) must be indicated at any location on the exterior of the end product or
product packaging or product literature which shall be available with the end product or online.
Table for Filed Antenna
Ant
Brand
Model name
Antenna Type
Connector
Band
Gain(dBi)
WNC
SWA51
Printed Antenna
N/A
B1
4.10
WNC
SWA51
Printed Antenna
N/A
B4
3.39
WNC
SWA51
Printed Antenna
N/A
B1
2.17
WNC
SWA51
Printed Antenna
N/A
B4
3.50
CONTENTS SUBJECT TO CHANGE WITHOUT NOTICE
17
CONFIDENTIAL

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : EmilyChen
Create Date                     : 2018:10:16 17:15:17+08:00
Modify Date                     : 2018:10:16 17:54:31+08:00
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Format                          : application/pdf
Title                           : Microsoft Word - SWA51 Module Datasheet FOR Regulation_0918 手冊 ok
Creator                         : EmilyChen
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2018:10:16 17:54:31+08:00
Producer                        : Acrobat Distiller 15.0 (Windows)
Document ID                     : uuid:22493ab4-8db6-4a3d-887a-07268479ee44
Instance ID                     : uuid:c1ebba12-f3a8-4150-b34c-7383e5ffbf50
Page Count                      : 17
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NKR-SWA51

Navigation menu