Wisycom s r l MTP40SUS8 POCKET TRANSMITTER User Manual MTP40S

Wisycom POCKET TRANSMITTER MTP40S

User Manual

                        MTP40S User Manual Wideband Wireless Professional Pocket Transmitter   SN:  ________________ Rev.08 (ref. FW 1.30.0P)  Date: 17 May 2018
MTP40S User Manual   2  INTRODUCTION “MTP40S  is an extremely small and light pocket transmitter especially designed for  professional wireless microphone applications” Very easy and quick to use thanks to OLED display, dedicated buttons and a joggle selector. MTP40S benefits also of the latest Wisycom  RF technology along with an enhanced robustness against noise and inter-modulation.   Fig. 1           ❶ Switch to enable wireless transmission, it also indicates the battery status and peak/mute operation (with PTT) ❷ In order to allow front visibility same colour information on (1) is replicated with this LED ❸ Oled display for transmitter setup ❹ <ch>, <gain> and 3 positions <selector> ❺ Battery holder ❻ Cover (to open push side buttons)  1.                                                  6 5 4 3 2 Turn on wireless: Move the Wireless power switch in “I” position. 1 Open MIC Body: Push the side buttons and flip down the  cover, to access internal setup controls and batteries.           Turn on display: Push <select switch> and hold it.   Front  LED RGB. Fig. 2
   MTP40S User Manual      3                                                                                      SAFETY INSTRUCTION  Read this safety instruction and the manual first  Follow all instructions and information.  Do not lose this manual.  Do not use this apparatus under the rain or near the water.  Do  not  install  the  apparatus  near  heaters  or  in  hot  environments,  do  not  use  outside  the operating temperature range.  Do not open the apparatus, only qualified service technician are enabled to operate on it. The apparatus needs servicing when it is not properly working or is damaged by liquids, moisture or other objects are fallen in the apparatus.  Use only accessories or replacement parts authorized or specified by the manufacturer.  Clean the apparatus only with dry cloths, do not use liquids.  Report the serial number and the purchasing date in front of the manual. It is needed to have proper replacement parts or accessories from the manufacturer.  When  replacement  parts  are  needed,  use  only  replacement  parts  authorized  from  the manufacturer. Substitution with not authorized parts could result in electric shock, hazards or fire.  Keep attention on all the labels with warnings or hazards on the apparatus. LED INDICATIONS Led indication with LED RGB (red, green, blue) in front led (❷): -  Wireless transmission status: Green when RF transmission power is on (on power on the device, this LED is red and become green when the RF transmission power is on).  -  Battery status: green steady, slowly blinking (< 25%), quickly blinking (<12%). -  Modulation peek (if activated and the limiter is disabled): red.  -  Ptt status: red if active (push to talk “pushed”). -     Limiter in action (if activated): blue. BATTERIES MTP40S  is  working  with  2  AA  alkaline,  NiMH  or  Lithium  batteries  (select  correct  type  on  setup controls). Battery status can be checked on internal OLED display or looking the LED status on front ❷. BATTERY SUBSTITUTION  Open transmitter cover and insert batteries following polarity indicated.  Attention: always replace both the batteries
MTP40S User Manual   4  POWERING UP Move the wireless  power switch (see Fig. 1)  in  “I”  position to activate wireless  transmission:  the front LED  ❷ lights up red and  then green when the RF transmission power is on (blinking when battery is low!) SETUP CONTROL Open transmitter Body to access the “display and controls” area (Fig. 3): A. Graphics Display (OLED) B. Channel selection buttons (ch) C. MIC gain setup buttons (gain) D. 3 position selector (up / down / click)                  Fig. 3  OLED POWER UP (OLED IS  IN OFF CONDITION) Pushing down selector (click), oled turns on. A first menu with serial NO and brand logo is displayed, then <status> menu enters automatically. Pushing and holding selector, serial NO menu is displayed.  OLED POWER DOWN (OLED IS IN ON CONDITION) Display turns off automatically after 15 sec, unless in <AUDIO> menu (with audio level < 5% from nominal).  + - CLICK  A  B  C  D
   MTP40S User Manual      5 DISPLAY MENU Setup menu are accessed in sequence:                                         MENU STATUS PRESET Current Load  FACTORY/USER/PRESET1/2/3/4/5/6/7/8 Save  USER TUNING CH 00-59 GR 00-39 Freq  according to the freq. range of the transmitter AUDIO AF In Gain AF Level -60 ÷ +40 dB (1dB step) -54 ÷ +46 dBu (1dBu step) Phase  0/180 HPass Filter  Flat/60/80/120/170/250/400Hz Noise R.  ENR-Wisy/ENC-Wisy Limiter  On/Off MIC Mode  2 wires/2wires+bias/3 wires/ 2wire&pha/2w+bias&pha PTT  Disable/Normal/Muting/No Data Name RF/Battery RF Power  10/20/50/100mW * Battery  Alkaline/NiMH/Lithium LED  Led Light  0÷16 Led Mode  None/ModPeak/PTT Info IRDA Lock Preset parameters * Depending on the Power Profile
MTP40S User Manual   6  + - CLICK Using <+/-> selector all menus can be accessed in sequence, push <click> to enter edit mode (in the left side of the display appear the word EDIT and the parameter start blinking): <+/-> to setup field <click> again to confirm changes and exit. exit without confirmation if no button is pressed after a few seconds time out.  <START UP> menu  These menus are displayed during power up for few seconds.    First one gives information of antenna to be used. The number displayed is the center-band of the antenna to be used.    The second menu gives indication on product: - product id (MTP40S),  - the firmware release (ex. 1.30.0A),  - the band in extended format and  - the serial number. Keep selector pushed to hold this menu! <STATUS> menu  This is the first menu displayed after power up.   Major info are displayed: - Current channel/group (i.e. CH:00 GR:39) - Current frequency (i.e. 566.000 MHz) - Mic gain (i.e. AF: +00 dB) and high pass filter (i.e. HP:60 Hz) - “RF 100” or RF 50” or “RF 10” on top right if RF transmission is active respectively at 100mW or 50mW or 10mW - On left, battery bar is displayed <PRESET> menu  This menu can be entered by scrolling selector, or pushing at the same time both quick channel setup buttons (<ch> & <gain>).  MTP40S can recall configuration presets. “FACTORY” recalls the Wisycom factory configuration. “USER” recalls the user configuration (the transmitter configuration is copied into the USER using the “save to” submenu). All “USER” menus are not locked by default, thus this is quick way to unlock features! When the user changes some parameters from the PRESET configuration (for less than frequency) a star appears on the top-right corner until a save command is executed. The other  8 configuration presets are user programmable thru the infrared and the PC interface (using the programmer UPK 300/UPKMini or the receiver MRK950/MRK960).  We provide the device with some preset configurations specifically designed for certain types of microphone or applications (it’s possible to change these presets in any time using the TX manager). All parameters can be “left unchanged”, “changed” or “changed and lock”, allowing a very flexible way to pre-program MTP40S configuration.
   MTP40S User Manual      7 <TUNING> menu  This menu can be entered by scrolling selector or using quick channel setup buttons (<ch>).  In this menu current channel/group and frequencies can be setup.  The name of the group is shown on the top right of the display. Sync group is a quick self-settable channel synchronized by receiver (with SYNC group, on the top right of the display is shown the name of the synchronized receiver). Use the selector to change values (<+/->) and <click> to confirm. Using quick channel setup buttons (<CH>), it is possible to enter quickly in the tuning menu. Note that the menu has a different layout (see the side image) <AUDIO> menu  This menu can be entered by scrolling selector or using quick gain setup buttons (<gain>).         The sensitivity of the audio input is settable between “AF Gain” (measured in dB) or “AF Level” (measured in dBu).  To help proper audio gain setting, an audio bar is supplied (with maximum peak indicator) indicating the headroom to audio peak (0 dB , nominal deviation 40KHz). Set the gain, with the maximum input signal, avoiding the peak on the audio bar. TRY TO SETUP TO HAVE A MAX PEAK HOLD BAR CLOSE TO -6dB. Using quick gain setup buttons (<GAIN>), it is possible to enter quickly in the audio gain menu. Note that the menu has a different layout (see the side image)                             The second <AUDIO> menu allows to set:  - Audio phase: 0° or 180° Note:  Since  common  "2-wires  +  bias"  microphones  invert  the phase, when the MIC mode of the transmitter is set to “2wires+ bias”, the phase is automatically inverted and so the complete system  (MTP4x+MIC)  has  0° phase  (an  asterisk  appear  on  the display near the phase to indicate that the phase was inverted). -High  Pass  Filter:  applies  different  audio  HP  filter:  Flat/  60Hz/ 80Hz/ 120Hz/ 170Hz/ 250Hz/ 400Hz.  The third <AUDIO> menu allows to set:  -Noise reduction:  ENR-Wisy: designed for maximum noise reduction  ENC-Wisy: designed for maximum audio fidelity (use this in case of special vocal application or to remote instruments) -Limiter: if is set “On”, an input audio signal above the peak threshold (up to 30 dB above peak) is not cut but attenuate, without lost quality. The limiter acts as a variable attenuator (thanks to the feedback system), maintaining a distortion <3%.  When the limiter intervene, the front led turns blue.                     If this parameter is set “Off”, the limiter is disable.
MTP40S User Manual   8  <RF/BATTERY> menu  This menu can be entered by scrolling selector.    RF power can be setup to 10mW, 20mW, 50mW or 100mW (depending on the Power profile). Use the Battery menu to select the type of battery used.  MTP40S support Alkaline/NiMH/Lithium battery type. Use the selector to change values (<+/->) and <click> to confirm. <LED> menu  This menu can be entered by scrolling selector.    Led Light allows to change the brightness of the front led (0÷16) .    Led Mode: - None: allows to disable modulation peak LED on front    led (the red light) - ModPeak: allows to enable modulation peak LED on front led (become RED when audio get close to saturation when the limiter is not enable) - PTT: allows to enable RED color on front led when PTT button is pushed. <MIC> menu  This menu can be entered by scrolling selector.   Mode: Following Mic mode can be setup (for LEMO option) -2 wires: (PTT is possible) for external audio input -2 wires + bias: (PTT is possible) for most 2 wires MIC -3 wires: (no PTT) for most 3 wires MIC -2 wires & pha: to connect a wired mic thru a 48V adapter (PHA48) -2 wires+bias & pha: Allow to connect a ‘2 wires + bias’ MIC or a ‘2 wires &  phantom’ MIC (with PHA48) PTT setting defines how and what information the transmitter has to send in normal use or when the PTT button is pushed. - Disable: when the PTT button is pushed, nothing happen. (the transmitter sends AF+Tone squelch) - Normal: when the PTT button is pushed, the transmitter send a different RF signal. According to the receiver configuration the audio can be enabled/disable on LINE (and/or COM). - Muting: the transmitter doesn’t send the audio. The voice is cut, it doesn’t enter to the  microphone - No Data: the transmitter sends neither tone squelch nor battery data. Use the selector to change values (<+/->) and <click> to confirm. NOTE: For DPA option (2 pin microdot audio connector), even if the MIC mode menu allows to set one of the 5 MIC modes, only 2 wires or 2 wires+bias mode are possible.  <NAME> menu This menu can be entered by scrolling selector.  In this menu it’s possible to see the frequency set on the device and the name of the transmitter. It’s possible to enter on this menu also pressing at the same time the CH/GAIN buttons ( B + C )
   MTP40S User Manual      9 <INFO> menu This menu can be entered by scrolling selector.  In this menu it’s possible to see: - FW version - HW version - Serial number - Bandwidth - Bootloader version - Option <IRDA> menu  This menu can be entered by scrolling selector.   While there is this menu, the device can be connected to IRDA for setup or firmware upgrades. Note: if the IRDA interface is enabled and there’s no communication for around 10 seconds, the IRDA interface is automatically turned off. On power on the device, the IRDA interface is enabled for 14 seconds. <LOCK> menu  This menu can be entered by scrolling selector.    Long pressing (2 sec.) selector button (click) it locks MTP40S in transmission mode. To unlock, long pressing (2 sec.) selector button again. <BOOTLOAD> menu  This menu can be entered by turning on the transmitter while pushing at the same time both quick channel setup buttons (<ch> & <gain>) or connecting the device via IRDA using the IR Programmer for FW update   Device is forced in bootloader mode to allow FIRMWARE UPDATE.
MTP40S User Manual   10  The following table sums up which parameters can be set and the related range settings. MENU PARAMETER MEANING RANGE SETTINGS TUNING CH Channel 0 ÷ 59 GR Group 0 ÷ 39 + SYNC GROUP Freq Frequency depends on the MTP40S band see technical spec. and variants for further details AUDIO AF In Gain AF Level Gain of the audio signal -60dB ÷ +40dB step of 1dB -54dBu ÷ +46dBu step of 1dBu Phase Audio signal phase 0° or 180°  HP Filt. High Pass filter Flat/60/80/120/170/250/400 Hz Noise R. Noise reduction ENR: Wisycom Extended-NR, noise optimized  ENC: Wisycom Extended-NC, voice optimized Limiter Limiter On/Off RF/BATTERY RF Power RF Power 10mW, 20mW, 50mW, 100mW (depending on the power profile) Battery Battery type Alkaline, NiMH or Lithium LED Led Light Power switch green brightness 0 ÷ 16 Led Mode It defines  when the power switch led   (see Fig. 3) has to become RED None: never ModPeak: when audio get close to saturation PTT: when the PTT button is pushed MIC Mode MIC type ’2 wires’ ‘2 wires + bias’ ‘3 wires’ ‘2 wires &  phantom’ ‘2 wires + bias &  phantom’ PTT Mode It defines how and what information the transmitter has to send  Disable:when the PTT button is pushed, nothing happen. (the transmitter sends AF+Tone squelch) Normal: when the PTT button is pushed, the transmitter send a different RF signal. According to the receiver configuration the audio can be  enabled/disable  on LINE (and/or COM).  Muting: the transmitter doesn’t send the audio. The voice is cut, it doesn’t enter to the microphone No Data: the transmitter sends neither tone squelch nor battery data.
   MTP40S User Manual      11 MIC Mode setting (only for LEMO option): MIC Mode: Pin out  Gain PTT Led Mode ’2 wires’:     1=GND 3=AF -60/40 dB Disable  Normal  Muting  No data None Mod. Peak PTT ‘2 wires + bias’:  1=GND 3=AF+5.5V -60/40 dB Disable Normal Muting No data None Mod. peak PTT ‘3 wires’:  1=GND 2=5.5V 3=AF -60/40 dB Disable No data None Mod. peak ‘2 wires &  phantom’: 1=GND 2=3.1V (power for PHA48) 3=AF -60/40 dB Disable No data None Mod. peak ‘2 wires + bias &  phantom’: 1=GND 2=3. 1V (power for PHA48) 3=AF+5,5V -60/40 dB Disable No data None Mod. peak   3 PIN LEMO CONNECTOR (use FVB.00.003.NLN on Mic)
MTP40S User Manual   12  ACCESSORIES AND PARTS  AWF30-B1-507 For MTP40S-X-X1 Band 470 ÷ 547 MHz Antenna Code label 507 AWF30-B1-590 For MTP40S-X-X1 Band 547 ÷ 640 MHz  Antenna Code label 590  AWF30-B2-616 For MTP40S-X-X2 Band 566 ÷ 672 MHz Antenna Code label 616 AWF30-B2-732 For MTP40S-X-X2 Band 672 ÷ 798 MHz  Antenna Code label 732  AWF30-B3-552 For MTP40S-X-X3 Band 510 ÷ 595 MHz  Antenna Code label 552 AWF30-B3-646 For MTP40S-X-X3 Band 595 ÷ 698 MHz Antenna Code label 646   CAL48 Cable to connect an MTP30 (with option /PHA) or  MTP40/40S to a PHA48 to use microphone with  XL3/48V connection CAL120 AF cable (120cm), LEMO 3pole / XLR-3F connectors PHA48 Plug-on for XLR3 Mic with 48V Phantom power. To be used with CAL48 (connected to an MTP30/40/40S) NEW REV2 with 4mA Phantom current!  ADT40 Power Adapter for MTP30/40/40S. Power input: 9-18V DC feeding (internal switching regulation). Variants: ADT40: without connector (pigtail)    (Shield= GND  ,  Blue-Red= Vdc) ADT40X: with XLR-4pin power connector ADT40H: with Hirose-4pin power connector NOTE: MTP30/40/40S must have ADT option to pass thru cable  UPK300E / UPK Mini Infrared programming kit (interface + software) USB interface    UPK300E UPK Mini Antenna Code label
   MTP40S User Manual      13 HOW TO USE WISYCOM TX MANAGER Wisycom TX Manager allows to read, modify and update the configuration of Wisycom transmitters. It is necessary to   connected the programmer UPK300E/UPKMini or the receiver MRK950/MRK960 to the PC thru USB connection   run the Wisycom TX Manager  enable the IRDA communication on the transmitter (see IRDA menu) NOTE: Wisycom IR Programmer doesn’t work whit MRK950/MRK960 if it is connected to the PC using an Ethernet cable.  The Wisycom IR Programmer’s window is divided in 4 parts (see the image below): ❶Interface and Device panel contains all the major information of the connected device  ❷Current Settings panel shows the current configuration. Thanks the PRESET panel, a previous saved configuration can be chosen and loaded like current setting. ❸Tuning Frequencies panel allows to handle Groups, Channels and Frequencies ❹Presets panel allows to read, change and save different configurations  ❶ ❷ ❸ ❹
MTP40S User Manual   14  10 different configurations are available: • FACTORY configuration is a locked configuration: no parameter can be changed.  USER configuration is the only configuration that can be saved using the OLED display (see <PRESET>  menu). Note: It is not possible to change the name of this configuration.  Other 8 configurations where the user can change both the name and the values of all parameters.  INTERFACE AND DEVICE PANEL (❶) At the beginning, the program checks which IR devices are detected and they appears on the Interface panel. The user has to select the device and push <connect> button in order to open the communication with the IR device. A picture on the top in the Interface panel help the user in this selection showing the type of devices detected. During this process the “IR activity” led blinks to indicate that the program wait connection’s answer from the IR device.  A successful connection is signaled with the “interface connection” green led, while a failed connection is signaled with the “communication error” led. Once a supported device is found, the software automatically reads all the data related to the remote configuration, as well as the frequencies that are pre-programmed.  Firstly, in order to avoid unwanted operation, no parameters can be changes and the EDIT button, presents on the bottom of Device panel, is yellow and set to LOCKED state.  Pushing the EDIT button, it becomes grey and sets to UNLOCKED state to indicate that the configurations can be modified. In this panel it’s possible to assign a name to the TX (not available for FW v.1.22.0F or previous). Under this parameter, there is a flag to hide the info menu on the TX (not available for FW v.1.22.0F or previous) CURRENT SETTINGS PANEL (❷) In the Current Settings panel the user can  with Preset panel → load one of the 10 available configurations    with  other  panels  →  modify  all  the  configuration’s  parameters  (the  same  that  are changeable  in  the  OLED  display).  Each  parameter  can  be  locked  or  hidden  clicking  the related lock/hidden button, so the set value cannot be changed next or cannot be visible on the OLED display.  ATTENTION: All the modifies applied to the Current Settings panel are instantaneous: they are applied directly to the device and save in its memory but no saved in the preset configuration.
   MTP40S User Manual      15 TUNING FREQUENCIES PANEL (❸) With the Tuning Frequencies panel the user can select a frequencies group (0÷39) and for each one execute the following operations: - modify the Group’s Name  - lock and/or hidden the group - for each channel (0 ÷59) of the selected group: change the frequency value and the related status (locked/hidden) (in the center grid frequency) The SAVE button, at the top of the panel, save the changes of the group selected (name group, lock/hidden group).   To change a frequency value  for  a  specific channel:  double  click on  the  grid  frequency panel  (row=channel’s number),  insert  the new  frequency  value and press OK button.   To lock/hide a specific channel, double click on the grid frequency panel.  NOTE: keeping pressed the CTRL button on the keyboard and clicking the wanted channel/group shown on the frequencies grid, the tuning process is executed. It is equivalent to configure the Tuning in the Current Settings panel but it is easier.  The device is re-tuned immediately, so be sure that the RF power is turned off while changing frequencies with other RF systems in use around you!
MTP40S User Manual   16  If the currently tuned channel is on the same group that is listed on the grid, the background color of the related cell (channel) on the grid becomes yellow.  Using the LOAD/SAVE button, at the bottom of the panel, it is possible to load/save the frequencies for the selected group from/to a .wdf file. To save the frequencies of all the groups click to the related button above. The legacy option save the channels without the hidden/lock info.
   MTP40S User Manual      17 PRESETS PANEL (❹) The Preset panel allows to manage all the 10s available configurations. For each configuration it is possible to set the name and all the parameters value except for FACTORY and USER configurations (see table below). PRESETS: NAME* LOCK/DON’T CARE PARAMETERS VALUE FACTORY    USER   √ OTHERS √ √ √ √=change is allowed * Be careful to write a meaningful name for the preset because the name will appear on the settings list of the device menu! Please, avoid empty names.  If a parameter is “locked”, it cannot be modified by device menu (using OLED display), while if “don’t care” propriety is active, when the user load the configuration, the parameter’s value doesn’t changed. ATTENTION: Changes are applied only after a “save” action. NOTE: “a trick” In case of the user have a locked parameter and he is in great need for modify it, he can save the configuration to USER configuration by OLED (see PRESET menu) and then load the USER configuration (in this way all the parameters have the lock propriety disable and the user can modify all the parameters).   FILE MENU Using a file menu at the top left of the panel it is possible to load/save all the configuration values of the device to/from a .wcf file (Wisycom Configuration File). Save a .wcf file With an infrared device correctly connected, select File->Save User Configuration and select the destination file.  Load a .wcf file  To load a user configuration select File->Load User Configuration and select a previously saved data file; a form will be shown, where it's possible to select which data has to be restored and which skipped. This allow the user to load a particular configuration while keeping other data.
MTP40S User Manual   18  TECHNICAL SPECIFICATIONS Switchable channels 2400 allocated by 40 groups of  60 channels (in specific frequency range), quickly selectable with dedicated buttons Switching window Up to 232 MHz, depending on band (see Variants on the next page) Frequencies Quartz PLL  frequency synthesizer circuit (25 kHz step) Frequency stability ± 2,5 ppm (in the rated temperature range) Temp. range -10 ÷ +55 °C Max RF power ▪  10mW (ERP) (to respect some local norm) ▪  20/50/100 mW (ERP) (note: in some countries middle power can be disabled, for local norm!) Spurious emissions < 2 nW Modulation wideband FM, with pre-emphasis Nominal deviation ±40 kHz  (Peak deviation =  ±56 kHz) Telemetry feature MTP40S transmits also a digitally modulated sub-carrier, suitable for:   ▪tone-squelch operating     ▪ remote battery monitoring   ▪ optional PTT (push to talk) operation  AF input connector LEMO option Configurable on ‘mic’ display menu in 5 options: ▪ ’2 wires’:     ▪ ‘2 wires + bias’:  ▪ ‘3 wires:  ▪ ‘2 wires &  phantom’  ▪ ‘2 wires + bias &  phantom’:  gain selectable -60 ÷ +40 dB (-54 dBu ÷ +46 dBu peak), no bias voltage gain selectable -60 ÷ +40 dB (-54 dBu ÷ + 46 dBu peak), 5.5 V on 4k7 bias supply gain selectable -60 ÷ +40 dB (-54 dBu ÷ +46 dBu peak) gain selectable -60 ÷ +40 dB (-54 dBu ÷ +46 dBu peak),  gain selectable -60 ÷ +40 dB (-54 dBu ÷ + 46 dBu peak), 5.5 V on 4k7 bias supply  AF input level 100 dB adjustable range from -54dBu (775 uV) to 46dBu (15.5 V) at peak deviation (1kHz),  adjustable in 1 dB steps Max. input level +46 dBu (15.5 V) at clipping, +20 dBu (7.75 V) at nominal level Noise-Reduction ENR  (Wisycom Extended-NR), with independent Attack- and Recovery-time, noise optimized ENC  (Wisycom Extended-NC), with independent Attack- and Recovery-time, voice optimized & with reduced pre-emphasis AF bandwidth ▪  45 Hz ÷ 21 KHz (3dB) ▪  55 Hz ÷ 20 KHz (1dB) Distortion < 0.3 %   (0.15 % typ.) Signal-to-noise ratio ▪  typ. 115 dB (A)rms with 40 kHz deviation ▪  typ. 121 dB (A)rms with 56 kHz deviation Led Led indication with RGB led (red, green, blue) on wireless power switch: ▪   Wireless transmission status:       GREEN on/off ▪   Battery lifetime status: GREEN - steady (> 25%) - slowly blinking (< 25%)  - quickly blinking  (<12%) ▪   Modulation peek (if activated & the limiter is disabled): RED ▪   Ptt status: RED if active ▪   Limiter into action: Blue  Display High contrast OLED (Organic light-emitting diode) white display (128 x 32 pixels) 8 step battery lifetime indication: 7 bars (100%-87%-75%-63-50%-38%-25%) and “empty bar” quickly blinking (12% remaining)  PTT function Pin 3 of the AF connector can be setup to an external push button Power supply 2 AA size batteries (Alkaline, rechargeable NiMH or Lithium) MTP40S Battery life (2 AA alkaline) ▪  approx. 14 hours @ 10mW continuous working ▪  approx. 10 hours @ 50mW continuous working ▪  approx. 7 hours @ 100mW continuous working Dimensions 73 x 61 x 17.5 mm (Height-Width-Depth) without clip  Weight Approx. 80 g. without batteries (120g with batt.)
   MTP40S User Manual      19                         VARIANTS: ▪ AUDIO CONNECTOR  LM 3 PIN LEMO CONNECTOR DP 2 PIN DPA MICRODOT CONNECTOR ▪ COLOR  PV body color titanium gray (ceramic coating) BL body color black (powder coating) ▪ FREQUENCY RANGE B5 470-654 MHz B2 566-798 MHz B3 510-698 MHz B8 940-960 MHz      POWER PROFILE & COUNTRY FREQUENCY RANGE: EU max power 50mW (Europe) 0W1 / EUX max power 100mW (Europe) US max power 50mW (USA) USX max power 100mW (USA & Canada) JP max power 10mW (Japan) NZ max power 100mW (New Zealand)  CN max power 50mW (China) US8 max power 100mW (USA & Canada)  OPTIONS: ADT hole on battery housing for ADT40  For commercial code, see Variants area of Wisycom Products on website  MTP40S  Note: unit is mm
MTP40S User Manual   20  Compliance  Model In Compliance with Max Power Country MTP40S MTP40S-EU EN 301 489-1/-9 EN 600065 EN 300 422-1/-2 50mW Europe  MTP40S-0W1 MTP40S-EUX EN 301 489-1/-9 EN 600065 EN 300 422-1/-2 EN 300 454-1/-2 100mW*1 Europe  MTP40S-US  PART 74 FCC-ID: POUMTP40 Limited to 698MHz 50mW USA MTP40S-USX  PART 74 FCC-ID: POUMTP40SUSX RSS-123, RSS-102 IC: 11967A-MTP40SUSX Limited to 698MHz 100mW*2 USA, Canada MTP40S-US8  PART 74 FCC-ID: POUMTP40SUS8 Limited to  941.50-952.00MHz, 952.85-956.25MHz,  956.45-959.85MHz 100mW USA MTP40S-JP                     202-LSC057     Limited to 714 MHz 10mW Japan  MTP40S-NZ EN 300 422-1/-2 EN 300 454-1/-2 Limited to the range 502÷698MHz 100mW New Zealand  *1 MTP40S-0W1 / MTP40S-EUX is not an SRD device, thus it requires specific authorization by your local frequency authority! *2 in accordance with KDB 447498 D01 General RF Exposure Guidance v05r02.  Before putting the device into operation, please observe the respective country-specific regulations! R MIC marking identifier can be found in the battery compartment.
   MTP40S User Manual      21 MANUFACTURER DECLARATIONS In compliance with the following requirements  RoHS Directive (2002/95/EC)   WEEE Directive (2002/96/EC) Please dispose of the diversity transmitter at the end of its operational lifetime by  taking  it  to  your  local  collection  point  or  recycling  center  for  such equipment     Battery Directive (2006/66/EC) The  supplier  batteries  or  rechargeable  batteries  can  be  recycled.  Please dispose of them as special waste or return them to your specialist dealer. In order to protect the environment, only dispose of exhausted batteries.    FCC Conformity   The Wisycom microphone pocket transmitter model MTP40S complies with the following requirements:  - FCC (Federal Communications Commission) Part 74 Operation is subject to the following two conditions:  (1) This device may not cause harmful interference, and  (2) This device must accept any interference received, including interference that may cause undesired operations.  Changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  FCC ID can be found inside the battery compartment. FCC-ID: POUMTP40              MTP40S US option FCC-ID: POUMTP40SUSX    MTP40S USX option FCC-ID: POUMTP40SUS8    MTP40S US8 option
MTP40S User Manual   22  Industry Canada Conformity (MTP40S USX)  EN This  device  complies  with  Industry  Canada  RSS-123.  Operation  is  subject  to  the  following  two conditions:  (1)  this  device  may  not  cause  interference,  and  (2)  this  device  must  accept  any interference, including interference that may cause undesired operation of the device.  FR Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio RSS-123. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de  brouillage,  et  (2)  l’utilisateur  de  l’appareil  doit  accepter  tout  brouillage  radioélectrique  subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.  ITALY ONLY  Obblighi di informazione agli utilizzatori  ai sensi dell’art. 13 del Decreto Legislativo 25 luglio 2005, n. 151 “Attuazione delle Direttive 2002/95/CE, 2002/96/CE e 2003/108/CE, relative alla riduzione dell’uso di sostanze pericolose nelle apparecchiature elettriche ed elettroniche, nonché allo smaltimento dei rifiuti”  Smaltimento di apparecchiature elettriche ed elettroniche di tipo professionale Il simbolo del cassonetto barrato riportato sull’apparecchiatura o sulla sua confezione indica che il prodotto alla fine della propria vita utile deve essere raccolto separatamente dagli altri rifiuti.  La raccolta differenziata della presente apparecchiatura giunta a fine vita è organizzata e gestita dal produttore. L’utente che vorrà disfarsi della presente apparecchiatura dovrà quindi contattare il produttore e seguire il sistema che questo ha adottato per consentire la raccolta separata dell’apparecchiatura giunta a fine vita.  L’adeguata raccolta differenziata per l’avvio successivo dell’apparecchiatura dismessa al riciclaggio, al trattamento e allo smaltimento ambientale compatibile contribuisce ad evitare possibili effetti negativi sull’ambiente e sulla salute e favorisce il reimpiego e/o riciclo dei materiali di cui è composta l’apparecchiatura.  Lo smaltimento abusivo del prodotto da parte del detentore comporta l’applicazione delle sanzioni am-ministrative previste dalla normativa vigente.  Smaltimento batterie usate  Questo prodotto può contenere batterie. Questo simbolo apposto sulle batterie significa che non possono essere smaltite insieme a normali rifiuti domestici, bensì devono essere depositate negli appositi punti di raccolta delle batterie.   Iscrizione al Registro A.E.E. n. IT09100000006319 .
   MTP40S User Manual      23 DECLARATION OF CONFORMITY
MTP40S User Manual   24       Via Spin 156    I-36060 Romano d’Ezzelino    Italy Tel. +39 -0424 -382605    Fax +39 - 0424 - 382733 www.wisycom.com    e-mail: sales@wisycom.com