Wolf Dd36I Users Manual Web DD36_v6
DD36R to the manual 6e00078a-975f-0584-8dcd-f0711b0be1b1
2015-02-03
: Wolf Wolf-Dd36I-Users-Manual-477509 wolf-dd36i-users-manual-477509 wolf pdf
Open the PDF directly: View PDF
.
Page Count: 9
| Download | |
| Open PDF In Browser | View PDF |
Planning Information Models DD36 I and DD36 R Downdraft Systems Top cover available in three finishes Model DD36I Internal Blower Model DD36R In-Line or Remote Blower Aluminum mesh filters 9" (229) chimney elevation Remote-mounted control module Three-speed blower control Model DD36I 36" (914) downdraft ventilation system includes a 500 CFM internal blower. In-line and remote blower options are available for Model DD36R. Control module and top cover come in classic, platinum and carbon stainless steel finishes. Stainless steel filter covers Rating plate location The cooktop downdraft unit rises from the countertop to whisk away odors and smoke into the easy-toclean, five-layer mesh filter. The control module and top cover are available in the exclusive premium finishes of platinum or carbon stainless steel, or the standard classic stainless steel for ease in matching your cooktop. Wolf downdraft ventilation systems are recommended for use with Wolf electric and gas cooktops and integrated modules, excluding the unframed electric cooktops and electric grill, steamer and fryer modules. Wolf downdraft systems cannot be used with Wolf dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops. Dimensions in parentheses are in millimeters unless otherwise specified. 9/06 1 Planning Information Models DD36 I and DD36 R Downdraft Systems F E AT U R E S Classic, platinum or carbon stainless steel finishes available on control module and top cover Remote mounted control module Internal, in-line and remote blower options Three-speed blower control Filter clean timer lets you know when the filter needs cleaning Delay-off feature automatically turns unit off, chimney remains up LED indicators 9" (229) chimney elevation Downdraft control kit includes control module, top cover, mounting brackets, DIN connector and necessary hardware UL listed to US and Canadian safety standards Two and five year residential warranty – exclusions apply; warranty information can be found on our website, wolfappliance.com Stainless steel filter cover with dishwasher safe aluminum mesh filter OVERALL DIMENSIONS 36" 2 3/8" (914) (60) 9 1/16" (230) 32 1/4" (819) 1 1/2" (38) DEPTH OF DOWNDRAFT CHIMNEY Dimensions may vary by ± 1/8" (3). Dimensions in parentheses are in millimeters unless otherwise specified. 2 Planning Information Models DD36 I and DD36 R Downdraft Systems MODEL OPTIONS S P E C I F I C AT I O N S Downdraft with 500 CFM Internal Blower Included Overall Width DD36I Downdraft Only — In-Line or Remote Blower Required DD36R For Model DD36R see in-line and remote blower options below. 36" (914) 9 1/16" (230) Overall Height (above countertop) 2 3/8" (60) Overall Depth Duct Size (Model DD36I) 3 1/4" (83) x 10" (254) Duct Size (Model DD36R) 3 1/4" (83) x 14" (356) Discharge BLOWER OPTIONS Adjustable Electrical Supply Requirements 1100 CFM In-Line Blower 808332 900 CFM Remote Blower 801641 1200 CFM Remote Blower 801642 1500 CFM Remote Blower 804701 Refer to the Wolf Cooktop Ventilation Recommendations chart at the end of this section. Power Cord 110 /120 V AC, 60 Hz 15 amp dedicated circuit 2 1/2' (.8 m) power cord with 3-prong grounded plug Shipping Weight 80 lbs (36 kg) Specifications are subject to change without notice. TRIM OPTIONS Classic Stainless DD36CONTROL/S Platinum Stainless DD36CONTROL/P Carbon Stainless DD36CONTROL/B Control module and top cover are available in these finishes. Control kits also include mounting brackets, DIN connector and hardware. They are available as sales accessories through your Wolf dealer. ACCESSORIES Transitions in various sizes Accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com. C O U N T E R T O P C U T- O U T 23/4" (70) 33" (838) 251/8" MIN (638) FLAT COUNTERTOP SPACE 191/4" COOKTOP CUT-OUT WIDTH (489) 21/2" MIN (64) Dimensions in parentheses are in millimeters unless otherwise specified. 3 Planning Information Models DD36 I and DD36 R Downdraft Systems 251/8" MIN (638) OF FLAT COUNTERTOP* 13/4" MIN (45) BACK EDGE OF COOKTOP TO INSIDE OF CABINET BACK* 5/8" (16) 21/2" MIN 191/4" (489) (64) WITH NO RAISED LIP* COOKTOP CUT-OUT DEPTH .344" 23/8" (60) 711/16" 21/8" (54) (197) 31/4" (83) 295/16" (745) COUNTERTOP TO BOTTOM OF AIR BOX 35/8" 36" (92) 5" 18" (127) (457) (914) 71/8" (181) 24" MIN (610) CABINET DEPTH *AREAS OF POTENTIAL INTERFERENCE L O C AT I O N O F E L E C T R I C A L 4" min (102) 24 " min (610) 3 1/2" (89) E E 10" (254) CABINET DEPTH ELECTRICAL LOCATION IN CABINET BACK 36" min (914) OPTIONAL ELECTRICAL LOCATION IN ADJACENT RIGHT SIDE CABINET DIMENSIONS Downdraft Cut-Out Width 33" (838) Recommended Cabinet Width 39" (991) Downdraft Cut-Out Depth 2 3/4" (70) Location of Electrical Within shaded area See Installation Instructions shipped with unit for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified. 4 Planning Information Models DD36 I and DD36 R Downdraft Systems I N S TA L L AT I O N N OT E S Refer to the illustrations and specifications for overall dimensions and installation specifics. Wolf downdraft ventilation systems are recommended for use with Wolf electric and gas cooktops and integrated modules, excluding the grill, steamer and fryer modules. The downdraft should be at least as wide as the cooking surface. IMPORTANT NOTE: Wolf downdraft ventilation systems cannot be used with Wolf dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops. A Wolf Pro ventilation hood should be used. The 36" (914) downdraft will fit most 36" (914) wide cabinets. Cabinet backs may need to be removed. It is recommended that oversized cabinets be used for easier installation. To incorporate a downdraft system and a Wolf cooktop, you must allow for a minimum 25 1/8" (638) flat counter space from front to back. A countertop with a raised lip and/or backsplash may not allow enough space for proper installation. 2 3/8" (60) of flat countertop is required behind the cooktop and 1 3/4" (44) is necessary between the back edge of the cooktop and inside of cabinet back. Follow dimensions given in the Countertop Cut-out illustration on page 3. Model DD36I has a 500 CFM internal blower. Model DD36R is shipped without the blower assembly. In-line and remote blower assemblies are available. Blower options vary with the volume of air that needs to be moved and the length of the duct run. Refer to the charts at the end of this section for cooktop ventilation recommendations and blower options. Wolf downdraft ventilation systems require a separate, grounded 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker and a grounded 3-prong receptacle should be located within the reach of the 2' (.6 m) power cord. The specific location of the outlet is not critical, as long as it is within reach of the power cord that is located mid-way, top and bottom on the right side of the downdraft. If the 36" (914) downdraft is being installed in a 36" (914) wide cabinet, the outlet cannot be located on the back wall of the cabinet. It is recommended that the outlet be placed in an adjacent cabinet within reach of the power cord. Refer to the Location of Electrical illustration on page 4. IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. This appliance must be used with a Wolf approved remote mounted control module and top cover, which is included in the downdraft control kit, available as a sales accessory. Installation of the control module must be within 10' (3 m) of the downdraft assembly and a minimum of 4" (102) from the outer edge of cooktop element or burner. You will be required to drill three holes and connect the two units by the provided wire. Refer to the installation instructions shipped with each Wolf product for detailed specifications. IMPORTANT NOTE: Install this downdraft only with a Wolf blower. Dimensions in parentheses are in millimeters unless otherwise specified. 5 Planning Information Models DD36 I and DD36 R Downdraft Systems D U C T I N G C O N S I D E R AT I O N S Except for Models DD30I, DD36I and DD45I, which include a 500 CFM internal blower, Wolf downdrafts are shipped without the blower assembly. In-line and remote blower assemblies are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com. Wolf downdraft systems have an adjustable discharge that will allow you to negotiate ducting around floor joists and other obstacles. Three different discharge locations are available with side to side adjustment for accurate alignment of ductwork. Refer to the illustration below for discharge location options. IMPORTANT NOTE: Install this downdraft ventilation system only with a Wolf blower. Discharge location options for internal and remote blower models. 163/8" (416) INTERNAL BLOWER 211/2" (546) CENTERLINE OF COUNTERTOP CUTOUT REMOTE BLOWER CL RIGHT DISCHARGE LOCATION 221/8" (562) INTERNAL BLOWER 19" (483) REMOTE BLOWER LEFT DISCHARGE LOCATION 51/2" (140) INTERNAL BLOWER 41/4" (108) REMOTE BLOWER DISCHARGE CUTOUT DIMENSIONS: 101/4" (260) x 31/2" (89) INTERNAL BLOWER 141/4" (362) x 31/2" (89) REMOTE BLOWER CENTERLINE OF COUNTERTOP CUTOUT CL ADJUSTMENT: 1" (25) - 7" (178) INTERNAL BLOWER 21/2" MAX (165) REMOTE BLOWER ADJUSTMENT: 5" MAX (127) REMOTE BLOWER BOTTOM DISCHARGE LOCATION 51/2" (140) INTERNAL BLOWER 41/4" (108) REMOTE BLOWER NOTE: Measurements are to centerline of duct cutouts Dimensions in parentheses are in millimeters unless otherwise specified. 6 Planning Information Models DD36 I and DD36 R Downdraft Systems D U C T I N G C O N S I D E R AT I O N S For best performance, 10" (254) round ductwork is recommended. The downdraft will operate most efficiently when ductwork does not exceed 40' (12 m) in length. Consult a qualified HVAC engineer for specific ducting applications. IMPORTANT NOTE: All Wolf downdrafts must be vented to the outside. Use only metal ductwork. Choose the ducting option that allows the shortest length of ductwork and a minimum number of elbows and transitions. Refer to the illustration below for ducting options. Refer to the cooktop ventilation charts at the end of this section for recommendations and blower options. Ducting options for downdraft Models DD36I and DD36R. 10" ROUND REMOTE BLOWER WALL CAP 12" MIN TO GROUND INTERNAL BLOWER INSTALLATION THROUGH WALL REMOTE BLOWER ROOF MOUNT INSTALLATION REMOTE BLOWER 10" ROUND 12" MIN TO GROUND 12" MIN TO GROUND INTERNAL BLOWER INSTALLATION THROUGH WALL Dimensions in parentheses are in millimeters unless otherwise specified. REMOTE BLOWER INSTALLATION THROUGH WALL 7 Planning Information Wolf Ventilation Recommendations WOLF BLOWER ASSEMBLIES A ventilation system must include a blower assembly. With a few exceptions where internal blowers are included, Wolf ventilation hoods and downdrafts are shipped without the blower assembly. An internal, in-line or remote blower assembly must be selected to accommodate the cooking appliance, CFM requirements and homeowner preferences. Internal, in-line and remote blower assemblies are available as sales accessories through your Wolf dealer. IMPORTANT NOTE: Use only a Wolf blower with all Wolf ventilation products. Internal blowers are mounted inside the hood canopy or downdraft blower box. In-line blowers are mounted in between the hood and the exterior of the home. Remote blowers can be mounted on the roof or in some cases, on an exterior wall. Refer to the illustrations below for dimensions of Wolf in-line and remote blowers. Ventilation recommendation charts on the following pages provide minimum CFM recommendations according to the cooking appliance and ventilation system used and blower options for each specific ventilation hood or downdraft. Wolf internal, in-line and remote blowers are for use with Wolf cooktop hoods, downdraft systems and Pro ventilation hoods and hood liners. 24 7/8" 24 3/8" (632) (619) 11 3/4" 18" (298) 12" (457) 18 1/2" (305) (470) 4 1/2" (114) 8" (203) 211/2" (546) 12 1/4" 22" (311) (559) In-line BLOWER-60IL 18" (457) In-line BLOWER-110IL 21" (533) 18" (457) 20 3/4" (527) 28 1/4" (718) (254) 29 1/2" 24 1/2" 14 3/4" 29 1/2" (375) (749) (622) 14" (356) 24 3/4" (629) (749) 10" (254) Diameter 15 1/2" 4 3/4" (121) Remote BLOWER-60REM and BLOWER-90REM (254) 29 1/2" (749) 10" (254) Diameter (394) 10" 10" 10" (254) Diameter 14 3/4" 29 1/2" (375) (749) 10 1/8" 10 3/8" (257) (264) 22" (559) 7 1/4" 25" 7 1/4" (184) (635) (184) Remote BLOWER-120REM Remote BLOWER-150REM Dimensions may vary by ± 1/8" (3). Dimensions in parentheses are in millimeters unless otherwise specified. 8 Planning Information Wolf Cooktop Ventilation Recommendations C O O K TO P V E N T I L AT I O N C F M R E C O M M E N DAT I O N S Cooktop Hoods, Downdrafts and Pro Hoods CTWH30 CTWH36 IH4227 DD30 DD36 DD45 Pro Hoods Model CT15E 215* 215* 215* Model CT30E 450 600 600 215* 150* 215* 500 350 Model CT30EU 450 600 600 600 Model CT36E 600 600 Model CT36EU 600 600 CTWH30 CTWH36 IH4227 DD30 Model CT15G 215* 215* 215* Model CT30G 450 600 600 600 600 CTWH30 CTWH36 IH4227 DD30 Model CT15I 215* 215* 215* 215* Model IG15 215* 215* 215* Model IS15 215* 215* 215* 215* Model IF15 215* 215* 215* 215* Model IM15 215* 215* 215* Electric Cooktops 600 500 600 600 DD36 DD45 Pro Hoods 215* 150* 215* 500 350 600 Gas Cooktops Model CT36G 500 DD36 600 DD45 Pro Hoods 150* 215* Modules 215* 215* 150* 215* *Use these requirements to determine total CFM when installing multiple cooktops or modules. CFM recommendations are based on total Btu/hr output. Wolf recommends 1 CFM per 100 Btu/hr (.03 kW). Additional CFM may be required for long duct runs. C O O K TO P V E N T I L AT I O N B L O W E R O P T I O N S Downdraft Systems Blower Description 500 CFM Internal 1100 CFM In-Line 900 CFM Remote 1200 CFM Remote 1500 CFM Remote Blower Number Downdraft Models Included with (I) Models DD30I / DD36I / DD45I BLOWER-110IL (808332) DD30R / DD36R / DD45R BLOWER-90REM (801641) DD30R / DD36R / DD45R BLOWER-120REM (801642) DD30R / DD36R / DD45R BLOWER-150REM (804701) DD30R / DD36R / DD45R 3 1/ 4" Adjustable discharge. (83) x 10" (254) duct for internal blower, no transition required. 3 1/4" (83) x 14" (254) duct for in-line and remote blowers. TRANS-14-10 required for remote blowers. Blower configurations are for reference only. Refer to minimum CFM recommendations for your specific cooking product. Always consult a qualified HVAC Engineer for specific applications. Dimensions in parentheses are in millimeters unless otherwise specified. 9
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 for Macintosh Modify Date : 2006:09:14 13:26:21-05:00 Creator Tool : QuarkXPress: pictwpstops filter 1.0 Create Date : 2006:09:14 13:26:21-05:00 Format : application/pdf Creator : Tom Pomplun Title : Web DD36_v6 Document ID : uuid:93f37854-441e-11db-a5de-0050e499a76d Instance ID : uuid:93f385b8-441e-11db-a5de-0050e499a76d Page Count : 9 Author : Tom PomplunEXIF Metadata provided by EXIF.tools